ADC Telecommunications DSC1902P Digivance® Street Coverage Solution “SCS” PCS/PCS User Manual 75187
ADC Telecommunications Inc Digivance® Street Coverage Solution SCS PCS/PCS 75187
Contents
- 1. User manual 1
- 2. User manual 2
User manual 2
ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Figure 2-9. NOC/NEM Interface Typical Commands The SNMP interface is used for remote control and monitoring operations (except software download and site number assignment). The SNMP interface uses a Management Information Base (MIB) to define a list of identifiers that are supported by the SNMP agent. The SNMP manager communicates with the SNMP agent over a LAN. Directives, based on the MIB identifier, are issued by the SNMP manager to the SNMP agent along with instructions to either get the specified identifier or set the specified identifier. The directive is then executed on the Digivance system by the SNMP agent. The SNMP agent also has the ability to send autonomous messages (called traps) to the SNMP manager to report changes in the status of the managed system. The SNMP manager Stargazer Version 8.0 is available from ADC for use with the LRCS SNMP agent. Other SNMP managers are available from various network management software venders. Refer to the SNMP Agent Software User Manual (see Related Publications section) for additional information. SPECIFICATIONS Refer to the following tables for the system, host unit, and remote unit specifications. All specifications apply after a five minute warm-up period. Table 2-5 – SCS 800/900 MHz SMR system nominal specifications Table 2-6 – SCS 800 MHz system nominal specifications Table 2-7 – SCS 1900 MHz system nominal specifications Table 2-8 – Host Unit nominal specifications Table 2-9 – WDM nominal specifications Table 2-10 – Remote Unit nominal specifications Page 2-18 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-5. SCS 800/900 MHz SMR System Nominal Specifications PARAMETER SPECIFICATION Optical - Host and Remote Unit Fiber type 9/125, single-mode Number of fibers required 1 for single-band remote unit 2 for dual-band RU Forward path wavelength 1550 nm Reverse path wavelength 1310 nm Optical transmit power output Host Unit Remote Unit Optical budget REMARKS All SCS remote units include a WDM. 0 dBm +1.3 dBm (includes WDM insertion loss) 25 dB For optical BER of 10–6 Optical Receiver Input Maximum –15 dBm Optical connectors RF Forward Path - 800/900 MHz System bandwidth UPC/SC Host unit OptiTap APC/SC Remote unit 18 MHz 5 MHz Frequency range 851–869 MHz 935–940 MHz Gain of forward path (Host input to Remote primary antenna port) 77.5 dB Gain flatness Band flatness Channel flatness 800 MHz transmit 900 MHz transmit At band center, room temperature, and 0 dB attenuation setting. Includes power amplifier. ± 2.0 dB across freq. range ± 1.5 dB variation across any 1.25 MHz channel Gain variation ± 3 dB over temp and unit-tounit Propagation delay < 6 µs (typical) Configurable propagation delay Range Step size 0 to 63 µs 0.1µs ± 100 ns Spurious In-band self generated Dynamic range (noise floor) <–13 dBm at remote output <–60 dBc at 30 KHz bandwidth Transmit peak-to-average >10 dB Two-tone Intermodulation <–55 dBc two tones @ 5 Watts each Nominal composite RF input signal level –40 dBm at 0 dB attenuation –9 dBm at max. attenuation –20 dBm is the optimal RF input signal level. Configurable input level Range Step size Excludes fiber delay Plus standard propagation delay 31 dB 1 ± 0.5 dB ±10% of attenuation monotonic Page 2-19 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-5. SCS 800/900 MHz SMR System Nominal Specifications, continued PARAMETER SPECIFICATION Composite RF Output power of both bands (see Note 1at end of table) 38.1 dBm (6.5 Watts) at remote 10 Watts at LPA output antenna port with –40 dBm input Configurable RF Output Range Step size Transmit path insertion loss RF Reverse Path - 800/900 MHz System bandwidth 31 dB at remote unit 1 ± 0.5 dB ± 10% of attenuation monotonic 2.5 dB maximum 18 MHz 5 MHz Frequency range 806–824 MHz 896–901 MHz Propagation delay < 8 µs (typical) Configurable propagation delay Range Step size Up to 63 µs 0.1µs ±1 100 ns Gain of reverse path Overall gain Gain variation Gain flatness Band flatness Channel flatness 800 MHz receive 900 MHz receive Excludes fiber delay Plus standard propagation delay 30 ± 2 dB at band center at room temperature 3 dB over temperature ± 2.0 dB across frequency range ± 1.5 dB variation across any 1.25 MHz channel Out-of-band rejection –40 dB bandwidth at < 30 MHz Spurious (in-band self generated) –110 dBm referred to input Intermodulation –62 dBc System noise figure 9 dB at mid-band Configurable RF output Range Step size REMARKS two tones @ –50 dBm 31 dB 1 ± 0.5 dB ± 10% of attenuation monotonic Blocking dynamic range 70 dB Level limiting ALC threshold –40 dBm ± 3 dB instantaneous Level limiting ALC range 27 dB Note 1: Per Industry Canada Section 5.3 - The rated output power of this equipment is for single carrier operation. For situations where multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Page 2-20 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-6. SCS 800 MHz System Nominal Specifications PARAMETER SPECIFICATION Optical - Host and Remote Unit Fiber type 9/125, single-mode Number of fibers required 1 for single-band remote unit 2 for dual-band RU Forward path wavelength 1550 nm Reverse path wavelength 1310 nm Optical transmit power output Host Unit Remote Unit Optical budget REMARKS All SCS remote units include a WDM. 0 dBm +1.3 dBm (includes WDM insertion loss) 25 dB For optical BER of 10–6 Optical Receive Input Maximum –15 dBm Optical connectors UPC/SC Host unit OptiTap APC/SC Remote unit RF Forward Path - 800 MHz System bandwidth A band B band 11 and 1.5 MHz 10 and 2.5 MHz Frequency range A band B band 869–880 and 890–891.5 MHz 880–890 and 891.5–894 MHz Out-of-band emissions Primary Gain of forward path (Host input to Remote primary antenna port) Gain flatness Band flatness Channel flatness –13 dBm per 1 MHz bandwidth from 10 kHz to 20 GHz 78.1 dB At band center, room temperature, and 0 dB attenuation setting. Includes power amplifier. ± 2.0 dB across freq. range ± 1 dB variation across any 1.25 MHz channel Gain variation ± 3 dB over temp and unit-tounit Out-of-band rejection –40 dB at > ±17.5 MHz from center of subband Propagation delay < 6 µs (typical) Configurable propagation delay Range Step size Up to 63 µs 0.1µs ± 100 ns Spurious In-band self generated Free dynamic range <–13 dBm at remote output <–60 dBc at 30 kHz bandwidth Transmit peak-to-average >10 dB Excludes fiber delay Plus standard propagation delay Page 2-21 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-6. SCS 800 MHz System Nominal Specifications, continued PARAMETER SPECIFICATION REMARKS Two-tone Intermodulation <–55 dBc at remote output Two tones @ 5 Watts each CDMA Intermodulation 885 kHz to 1.25 MHz 1.25 to 1.98 MHz 1.98 to 2.25 MHz –45 dBc per 30 kHz –8 dBm per 30 kHz –55 dBc per 30 kHz Nominal composite RF input signal level –40 dBm at 0 dB attenuation –9 dBm at max. attenuation Configurable input level Range Step size Composite RF Output power (see Note 1at end of table) Configurable RF Output Range Step size Absolute level 31 dB 1 ± 0.5 dB ±10% of attenuation monotonic 38.1 dBm (6.5 Watts) at remote 10 Watts at LPA output antenna port with –40 dBm input 31 dB at remote unit 1 ±0.5 dB ±10% of attenuation monotonic Transmit path insertion loss 2.5 dB maximum RF Reverse Path - 800 MHz System bandwidth A band B band 11 and 1.5 MHz 10 and 2.5 MHz Frequency range A band B band 824–835 and 845–846.5 MHz 835–845 and 846.5–849 MHz Propagation delay 6 µs Configurable propagation delay Range Step size Up to 63 µs 0.1µs ±1 100 ns Gain flatness Band flatness Channel flatness 1.5 dB across frequency range ±1 dB variation across any 1.25 MHz channel Gain of reverse path Overall gain An input signal level of –40 dBm provides maximum output power Excludes fiber delay Plus standard propagation delay 30 ± 2 dB at band center at room temperature 3 dB over temperature ALC not invoked Out-of-band rejection –40 dB at > ±17.5 MHz from center of subband ALC not invoked Spurious (in-band self generated) –110 dBm referred to input ALC not invoked Intermodulation –62 dBc two tones at –50 dBm System noise figure 8 dB at mid-band Gain variation Page 2-22 © 2005, ADC Telecommunications, Inc. ALC not invoked ALC not invoked ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-6. SCS 800 MHz System Nominal Specifications, continued PARAMETER Configurable RF output Range Step size SPECIFICATION REMARKS 31 dB 1 ± 0.5 dB ± 10% of attenuation monotonic Blocking dynamic range 70 dB Level limiting ALC threshold –40 dBm ± 3 dB instantaneous Level limiting ALC range 30 dB RF Forward and Reverse Path Modulation Accuracy Service/Mod Type/Parameter TDMA/n/4-DQSK/rms EVM GSM/GMSK/rms phase error EDGE/8PSK/rms EVM EIA-97D/CDMA/rho factor 7% 4º 7% .97% Note 1: Per Industry Canada Section 5.3 - The rated output power of this equipment is for single carrier operation. For situations where multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Page 2-23 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-7. SCS 1900 MHz System Nominal Specifications PARAMETER SPECIFICATION Optical - Host and Remote Unit Fiber type 9/125, single-mode Number of fibers required Forward path wavelength 1550 nm Reverse path wavelength 1310 nm Diversity path wavelength 1310 nm Optical transmit power output Host Unit Remote Unit 0 dBm +2 dBm Optical budget 25 dB Optical Receive Input –15 dBm Optical connectors Host Unit Remote Unit Industry standard SC Industry standard SC RF Forward Path - 1900 MHz System Bandwidth 1930 to 1950 MHz 1945 to 1970 MHz 1950 to 1975 MHz 1965 to 1990 MHz 1990 to 1995 MHz Out-of-band emissions (Primary) –13 dBm per 1 MHz bandwidth from 10 kHz to 20 GHz Gain of forward path (Host input to Remote primary antenna port) 78.3 dB At band center, room temperature, and 0 dB attenuation setting. Includes power amplifier. ± 1.5 dB across freq. range ± 1 dB variation across any 1.25 MHz channel Gain variation ± 3 dB over temp and unit-tounit Out-of-band rejection –40 dB at > ±17.5 MHz from center of subband Propagation delay < 2.5 µs Configurable propagation delay Range Step size Up to 63 µs 0.1µs ± 100 ns Page 2-24 © 2005, ADC Telecommunications, Inc. For optical BER of 10–6 20 MHz AD band, 25 MHz DBE, BEF, and EFC bands, 5 MHz G band. Frequency range AD DBE BEF EFC Gain flatness Band flatness Channel flatness REMARKS Excludes fiber delay Plus standard propagation delay ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-7. SCS 1900 MHz System Nominal Specifications, continued PARAMETER SPECIFICATION Spurious In-band self generated Free dynamic range –13 dBm at remote output 60 dB at 30 kHz bandwidth Transmit peak-to-average 10 dB Two-tone Intermodulation –55 dBc at remote output two tones at 5 Watts each CDMA Intermodulation 885 kHz to 1.25 MHz 1.25 to 1.98 MHz 1.98 to 2.25 MHz –45 dBc per 30 kHz –8 dBm per 30 kHz –55 dBc per 30 kHz Absolute level Nominal composite RF input signal level –40 dBm at 0 dB attenuation –9 dBm at max. attenuation An input signal level of –40 dBm provides maximum output power Configurable input level Range Step size Composite RF Output power (see Note 1 at end of table) Configurable RF Output Range Step size Transmit path insertion loss RF Reverse Path - 1900 MHz System Bandwidth 31 dB 1 ± 0.5 dB ±10% of attenuation monotonic 38.3 dBm (6.7 Watts) at remote antenna port with –40 dBm input 31 dB at remote unit 1 ±0.5 dB ±10% of attenuation monotonic 2.4 dB maximum 20 MHz AD band, 25 MHz DBE, BEF, and EFC bands. 5 MHz G band. Frequency range AD DBE BEF EFC 1850 to 1870 MHz 1865 to 1890 MHz 1870 to 1895 MHz 1885 to 1910 MHz 1910 to 1915 MHz Propagation delay 2.5 µs Maximum Configurable propagation delay Range Step size 0 to 63 µs 0.1µs ±1 100 ns Gain flatness Band flatness Channel flatness 1.5 dB across frequency range ±1 dB variation across any 1.25 MHz channel Gain of reverse path Overall gain Gain variation Out-of-band rejection REMARKS Excludes fiber delay Plus standard propagation delay 30 ± 2 dB at band center at room temperature 3 dB over temperature ALC not invoked –40 dB at > ±17.5 MHz from center of subband ALC not invoked ALC not invoked Page 2-25 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-7. SCS 1900 MHz System Nominal Specifications, continued PARAMETER SPECIFICATION REMARKS Spurious (in-band self generated) –110 dBm referred to input ALC not invoked Intermodulation –62 dBc two tones at –50 dBm System noise figure 8 dB at mid-band ALC not invoked Configurable RF output Range Step size 31 dB 1 ± 0.5 dB ± 10% of attenuation monotonic Blocking dynamic range 70 dB Level limiting ALC threshold –40 dBm ± 3 dB instantaneous Level limiting ALC range 30 dB RF Forward and Reverse Path Modulation Accuracy Service–Mod Type–Parameter TDMA–π/4-DQSK–rms EVM GSM–GMSK–rms phase error EDGE–8PSK–rms EVM EIA-97D–CDMA–rho factor Blank 7% 4º 7% 0.97% Note 1: Per Industry Canada Section 5.3 - The rated output power of this equipment is for single carrier operation. For situations where multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Page 2-26 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-8. Host Unit Nominal Specifications PARAMETER SPECIFICATION REMARKS 3.5 × 17.1 × 12.2 inches (88 × 433 × 311 mm) 3.5 × 17.2 × 15.3 inches (88 × 437 × 389 mm) Dimension for width does not include the mounting brackets which can be installed for either 19- or 23-inch racks. Mounting 19- or 23-inch rack EIA or WECO Weight 18 lbs. (8.2 kg) Weather resistance Indoor installation only Operating temperature 0º to 50º C (32º to 122º F) Storage temperature –40º to 70º C (–40º to 158ºF) Humidity 10% to 90% Optical ports UPC/SC External alarm connector Screw-type terminals DC power connector Screw-type terminal strip RF coaxial cable connectors 50 ohm N-type (female) 50 ohms input/output impedance Service connector DB-9 (female) RS-232 DTE interface Auxiliary connector DB-9 (female) Not used with SCS systems CAN connectors RJ-45 jack Voltage input Nominal ± 24 or ± 48 VDC Power consumption 55 watts Current rating 1 Amp at –48 VDC Reliability at 25ºC MTBF 80,000 hours Physical/Environmental/ Electrical - Host Unit Dimensions (H×W×D) Rear Access Front Access No condensation NO and NC relay contacts ± 21 to ± 60 VDC Excluding fans Table 2-9. Host Unit and Remote Unit WDM Nominal Specifications PARAMETER SPECIFICATION REMARKS Optical - WDM Passband 1310 nm ± 20 nm 1550 nm ± 20 nm Forward path insertion loss Host WDM Remote WDM 0.7 dB 0.3 dB Does not include connector loss Reverse path insertion loss Host WDM Remote WDM 0.3 dB 0.7 dB Does not include connector loss Isolation > 30 dB minimum Return loss (Reflectance) < –50 dB All input ports Page 2-27 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 2: DESCRIPTION Table 2-10. Remote Unit Nominal Specifications PARAMETER Physical/Environmental/ Electrical - Remote Unit Dimensions (L×W×D) Single-Band Dual-Band and Interim Single Band SPECIFICATION REMARKS 29.4 × 9.7 × 5.7 inches (747 × 246 × 145 mm) 37.3 × 10.2 × 7.5 inches (947 × 259 × 191 mm) Mounting Pole, wall, or strand mounted Weight Single-Band Dual-Band and Interim Single Band 42 lbs. (19.1 kg) 79.5 lbs. (36.1 kg) Weather resistance NEMA-6, IEC IP 67 Indoor or outdoor installation Lightning protection 20 kA IEC 1000-4-5 8/20 µs waveform With external protector (accessory) Operating temperature –30º to 50º C (–22º to 122º F) Storage temperature –40º to 70º C (–40º to 158ºF) Humidity 10% to 90% No condensation AC power connector Mini 3-pin 3-wire power cable included Antenna connector(s) 50 ohm N-type (female) 50 ohms input/output impedance Optical port(s) OptiTap APC/SC Requires angled-polish SC connectors Voltage input 90 to 265 VAC, 47 to 63 Hz 60 to 89 VAC, 47 to 63 Hz Standard Option With solar shields installed Power consumption Single-Band (all types) Dual-Band 300 Watts 600 Watts Current rating Single-Band (all types) Dual-Band 2.5 Amps at 120 VAC 5.0 Amps at 120 VAC Reliability at 25ºC MTBF - 80,000 hours Page 2-28 © 2005, ADC Telecommunications, Inc. Requires accessory kit for strand mounting ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION SECTION 3: OPERATION Content Page BEFORE STARTING OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 1.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 1.2 Readiness Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 TURN-UP SYSTEM AND VERIFY OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 2.1 Reference Procedure: Determine Forward Path Input Signal Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 2.2 Reference Procedure: Enter Site Name and Site Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 2.3 Reference Procedure: Enter Host Forward Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 2.4 Reference Procedure: Determine Output Signal Level at RU Antenna Port . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 2.5 Reference Procedure: Enter Remote Forward Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 2.6 Reference Procedure: Enter Host Reverse Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 2.7 Reference Procedure: Enter Host Forward and Reverse Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 _________________________________________________________________________________________________________ BEFORE STARTING OPERATION This section provides guidelines for turning-up the Digivance system, verifying that all units are operating properly, testing to ensure that all performance requirements are satisfied, and correcting any installation problems. This process assumes that the various units have been installed in accordance with the system design plan. 1.1 Tools and Materials The following tools and materials are required in order to complete the procedures in this section: • Portable spectrum analyzer or RF power meter • DC voltmeter • External RF and optical attenuators (if specified in system design plan) • PC-type computer with Digivance Element Management System (EMS) Version 3.01 software installed • Straight-through RS-232 DB-9 interface cable (accessory) • Handset • Pencil or pen • Writing pad Page 3-1 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 1.2 Readiness Check Before starting the turn-up process, inspect the complete Digivance system to verify that all components of the system are ready to be powered-up. This will ensure that no units of the system will be damaged during turn-up and that all existing systems will continue to function properly. 1.2.1 Host Unit Installation Checks Complete the following checks at the HU prior to starting the turn-up process: 1. Verify that the ON/OFF switch on the HU is in the OFF position (press O). Note: When connecting the equipment to the supply circuit, be sure to check equipment nameplate ratings to avoid overloading circuits which may cause damage to over-current protection devices and supply wiring. 2. At the fuse panel, install a 3 Amp GMT fuse in the circuit that supplies DC power to the HU. 3. Using a DC voltmeter, verify that the DC voltage level at the HU power terminals is between ± 21 to ± 60 VDC (nominal ± 24 or ± 48 VDC). The DC power provided to the HU can be either polarity. 4. Verify that all electrical and optical connections have been completed and that all optical fibers, coaxial cables, and wires are properly routed and secured. 1.2.2 Remote Unit Installation Checks Complete the following checks at the RU prior to starting the turn-up process: 1. Verify that all electrical and optical connections have been completed and that all optical fibers, coaxial cables, and wires are properly routed and secured. 2. At the AC breaker box, make sure the circuit breaker for the circuit that supplies AC power to the RU is in the open (off) position. TURN-UP SYSTEM AND VERIFY OPERATION The process of turning-up the system and verifying operation involves powering up the various system components, verifying that the LED indicators show normal operation, setting the site number and name, adjusting the RF signal levels, and adjusting the path delay. Note: SCS systems that include a dual-band RU are comprised of two systems that operate and function independently of each other. Each system can be independently turned-up, tested, and placed into service. The EMS will recognize each system regardless of the frequency/band and will display the appropriate screens. The frequency/band can be verified by clicking on the HOST Host tab and on the REMOTE STM tab. The frequency/ band for the selected system will be displayed on the right side of the screen. Page 3-2 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Each Digivance system must be turned-up separately before being networked together with multiple systems through the CAN interface. Use the following procedure to turn-up each Digivance system: 1. Temporarily disconnect the external alarm system or notify the alarm system provider that testing is in progress. 2. If the HU is networked together with multiple HU’s, temporarily disconnect the CAN cables from the NET IN and NET OUT ports of the HU. Note: By default, all HU’s and RU’s are programmed with the same site number and name. This can cause problems for the EMS if multiple HU’s with the same site number and site name are networked together through the CAN interface. It is therefore necessary to temporarily disconnect the CAN interface cables from the HU when it is being configured for operation until a unique site number and name can be assigned. 3. Determine if the forward path composite input signal level at the host unit RF IN port(s) is appropriate to produce the required RF output signal level. Note that 800/900 MHz SMR host units have two forward path RF ports. Adjust by installing an external attenuator if necessary. For adjustment purposes, the optimum input signal level is –20 dBm for 800/ 900 MHz SMR systems. Refer to Section 2.1 for the calculation and adjustment procedure. 4. At the HU: Place the ON/OFF switch on the HU in the ON position (press I). 5. At the RU: Place the AC circuit breaker switch in the closed (ON) position. 6. Wait 6 to 10 seconds for the HU and the RU to initialize and then observe the LED indicators on the HU and RU. Refer to Section 4: Maintenance for the troubleshooting procedures if the indicators do not respond as specified in Table 3-1. Table 3-1. LED Indicator Operation at Initial Turn-Up REAR ACCESS HOST UNIT FRONT ACCESS HOST UNIT POWER – Green STANDBY – Off HOST UNIT – Green REMOTE UNIT – Green POWER – Green STANDBY – Off HOST UNIT – Green REMOTE UNIT – Green DRIVE 851–869 – Green, Yellow, or Red DRIVE 935–940 – Green, Yellow, or Red DRIVE – Green, Yellow, or Red FWD/REV (PORT 1/PORT 2) – Green FWD/REV (PORT 1/PORT 2) – Green REMOTE UNIT STATUS – Off Note: This LED will stay red for 6 to 10 seconds while the RU initializes and then turn off. 7. Measure the input optical power level at the HU and RU and verify that the optical power level received at the HU and RU is within –15 to –25 dBm. Refer to Section 4: Maintenance for the optical power test procedure. 8. Connect the EMS computer (if not already connected) to the SERVICE connector on the HU front panel. If necessary, a separate laptop computer loaded with the EMS software can be temporarily connected and used to initially configure the system. Page 3-3 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 9. Start up the EMS software program. The EMS main window will open as shown in Figure 3-1. The EMS software should be installed on a PC-type computer and the PC’s COMM port should be configured to interface with the HU. For information about installing the EMS software and configuring the PC’s COMM port, refer to the Digivance Element Management System User Manual (see Related Publications section). Click to view drop down menu Figure 3-1. Digivance Element Management System Main Window 10. Open the View drop down menu and connect to the Host and Remote pair by selecting the “NotNamed/NotNamed” Host/Remote pair. The HOST Alarms display and the REMOTE Alarms display will open within the main window as shown in Figure 3-2. Host/Remote pair site name Clicking on the tabs in this list will open the corresponding display. Figure 3-2. Typical Host and Remote Alarms Display Page 3-4 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 11. New Control program software and FPGA program software will be provided separately on a “as needed” basis. If new Control and FPGA software is not provided with the system, proceed to step 12. If a Control and FPGA software upgrade is required, contact the ADC Technical Assistance Center (see Section 5) for help with the download procedure. 12. Click on the HOST Config tab and on the REMOTE Config tab (see Figure 3-2). The HOST Config display and the REMOTE Config display will open within the main window. 13. Enter the Site Name and Site Number for both the HOST and the REMOTE unit. Refer to Section 2.2 for details. Note: The Site Name and Site Number must be unique for each Digivance system. 14. If the Digivance system will be networked together with other Digivance systems, reconnect the CAN cables to the HU’s NET IN and NET OUT ports. 15. Verify that no Major or Minor alarms are being reported in either the HOST or REMOTE Alarm displays (except as indicated in the note below) and that all alarm fields are green. Note: The Host RF Underdrive may indicate a minor alarm until the Host Fwd Att and Remote Fwd Att values are set. 16. Click on the HOST RF tab (see Figure 3-2). The HOST RF display will open within the main window. 17. Enter the Host Fwd Att (Forward Attenuation) value. This sets the forward input RF signal level at the HU. Refer to Section 2.3 for details. By default, this value is set to 31 dB. If the DRIVE LED on the HU front panel was red, it should turn green when this step is completed. Note that 800/900 MHz SMR HU’s have two DRIVE LED’s. 18. Determine if the RF output power at the RU ANTENNA is at the correct level up to a composite maximum of +38.1 dBm (6.5 Watts) for 800 MHz and 800/900 MHz SMR systems or +38.3 dBm (6.7 Watts) for 1900 MHz systems. Refer to Section 2.4 for details. 19. Click on the REMOTE RF tab (see Figure 3-2). The REMOTE RF display will open within the main window. 20. Enter the Remote Fwd Att value. This adjusts the RF output signal level at the HU ANTENNA port. By default this value is set to 31 dB. Refer to Section 2.5 for details. 21. Click on the HOST RF tab (see Figure 3-2). The HOST RF display will open within the main window. 22. Enter the Host Rev Att (Reverse Attenuation) values. This sets the reverse output RF signal levels at the host unit RF OUT port(s). By default each value is set to 31 dB. Refer to Section 2.6 for details. Note that 800/900 MHz SMR host units have two REVERSE RF OUT ports. 23. If a delay adjustment is required, enter the Host Fwd Delay and Host Rev Delay values. By default, the delay values are set to 0. Refer to Section 2.7 for details. Page 3-5 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 24. If a separate laptop computer loaded with the EMS software was used to initially configure the system, disconnect the laptop computer from the SERVICE connector. Note: When two or more HU’s are connected together through the CAN interface, only one EMS computer is required to manage the networked Digivance systems. The EMS computer may be connected to the SERVICE port on any one of the HUs in the network. 25. Reconnect the external alarm system or notify the alarm system provider that the turn-up process has been completed. 2.1 Reference Procedure: Determine Forward Path Input Signal Level The level of the composite RF input signals received at the host unit FORWARD RF IN port(s) will vary depending on the EBTS, the cable loss, the number of channels present, and the required forward path composite power. If maximum composite RF output is required at the RU, the level of the composite RF input signal received at the HU must fall within a range of –9 to –40 dBm. If the signal level is not within this range, it must be adjusted using an external attenuator. Note: The 800/900 MHz SMR host unit has two FORWARD RF IN ports. Use the 851–869 FORWARD RF IN port to complete this procedure. Then repeat this procedure for the 935–940 FORWARD RF IN port. Note: The optimum level for an 800/900 MHz SMR composite input signal is –20 dBm When connecting a single HU to a single EBTS, use the following procedure to measure and adjust the input RF signal level at the HU: 1. Connect a spectrum analyzer or power meter to the forward path output port at the EBTS. The required signal levels and test points for 800/900 MHz SMR systems are shown in Figure 3-3. The required signal levels and test points for 800 MHz and 1900 MHz systems are shown in Figure 3-4. Note that 800/900 MHz SMR Host Units have two forward path ports. Note: Check the input rating of the test equipment and the output rating of the EBTS. To avoid burning out the spectrum analyzer or power meter, it may be necessary to insert a 30 dB 100W (or similar) attenuator between the EBTS and test equipment. 2. If using a spectrum analyzer, proceed to step 3. If using a power meter, measure the composite signal power from the EBTS and then proceed to step 5. 3. Measure the RF level of a single carrier, such as the control channel, in dBm. Make sure the resolution bandwidth of the spectrum analyzer is 30 kHz. Maximum power in any channel should not exceed 5W (+37 dB). 4. Calculate the total composite signal power from the EBTS using the following formula: Ptot = Pc + 10Log N where, Ptot is the total composite power in dBm Pc is the power per carrier in dBm as measured in step 3, and N is the total number of channels. Page 3-6 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION ENHANCED BASE TRANSCEIVER STATION 806-824 RECEIVER 896-901 RECEIVER 851-869 TRANSMITTER 935-940 TRANSMITTER EXTERNAL ATTENUATORS REVERSE PATH OUTPUT SIGNAL LEVEL AS SET BY HOST REVERSE PATH ATTENUATORS 0 to 31 dB ATTENUATORS (HOST REV ATT) 0 to 31 dB ATTENUATORS (HOST FWD ATT) HOST UNIT RF, OPTICS, AND CONTROL FORWARD PATH INPUT SIGNAL LEVEL AT HOST UNIT (-20 dBm OPTIMAL COMPOSITE FOR FULL POWER) FORWARD PATH SIGNAL LEVEL AS SET BY HOST FORWARD PATH ATTENUATORS (ADJUST TO -40 dBm COMPOSITE FOR FULL POWER) OPTICAL LINK RF, OPTICS, AND CONTROL 0 to 31 dB ATTENUATORS (REMOTE FWD ATT) REMOTE UNIT FORWARD PATH SIGNAL LEVEL AS SET BY REMOTE FORWARD PATH ATTENUATORS LPA ANTENNA QUADRAPLEXER/FILTER MAXIMUM OUTPUT SIGNAL LEVEL AT ANTENNA PORT (37 dBm AT FULL POWER) 20577-A Figure 3-3. Signal Levels, Test Points, and Adjustments for 800/900 MHz SMR Systems Page 3-7 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION ENHANSED BASE TRANSCEIVER STATION RECEIVER TRANSMITTER EXTERNAL ATTENUATOR REVERSE PATH OUTPUT SIGNAL LEVEL AS SET BY HOST REVERSE PATH ATTENUATOR FORWARD PATH INPUT SIGNAL LEVEL AT HOST UNIT (-20 dBm TYPICAL COMPOSITE FOR FULL POWER) HOST UNIT 0 to 31 dB ATTENUATOR (HOST REV ATT) 0 to 31 dB ATTENUATOR (HOST FWD ATT) RF, OPTICS, AND CONTROL FORWARD PATH SIGNAL LEVEL AS SET BY HOST FORWARD PATH ATTENUATOR (ADJUST TO -40 dBm COMPOSITE FOR FULL POWER) OPTICAL LINK REMOTE UNIT RF, OPTICS, AND CONTROL 0 to 31 dB ATTENUATOR (REMOTE FWD ATT) FORWARD PATH SIGNAL LEVEL AS SET BY REMOTE FORWARD PATH ATTENUATOR LPA PRIMARY ANTENNA MAXIMUM OUTPUT SIGNAL LEVEL AT ANTENNA PORT AT FULL POWER 38.1 dBm for 800 MHz 38.3 dBm for 1900 MHz DUPLEXER 20653-A Figure 3-4. Signal Levels, Test Points, and Adjustments for 800 MHz and 1900 MHz Systems Page 3-8 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 5. Determine the total cable loss that is imposed by the forward path coaxial cable that links the EBTS to the HU and also any insertion loss imposed by splitters or combiners. 6. Subtract the total cable loss and any insertion losses from the total composite power calculated in step 4. 7. Subtract –20 (optimum input signal level) from the value determined in step 6. The difference (which should be positive) equals the value of the external attenuator that is required to reduce the forward path signal level to the optimum level for input to the HU. The following formula outlines the required calculations for steps 6 and 7: Ptot – (Cable and insertion loss) – (–20) = Value of external attenuator required Note: If the input signal level is already –20 dBm, no external attenuator is required. 8. Select an attenuator that is as close to the value calculated in step 7 as possible. 9. Install the external attenuator in the coaxial cable that is connected to the corresponding FORWARD RF IN port at the HU. Caution: The Host Unit can be damaged if it is overdriven by the EBTS. Always install an external protective attenuator at the Host Unit FWD RF IN port if the forward path composite input signal level is greater than –9 dBm. 10. If turning up an 800/900 MHz SMR system, repeat steps 1–9 for the 935–940 FORWARD RF IN port at the HU. Install the external attenuator in the coaxial cable that is connected to the 935–940 FORWARD RF IN port at the HU. 11. Subtract the value of the external attenuator from the total composite signal power (Ptot) and record the result. This value will be required when setting the attenuation of the HU’s internal forward path attenuators. 2.2 Reference Procedure: Enter Site Name and Site Number All HU’s and RU’s are programmed with the same site name and site number. It is therefore necessary to assign a unique site name and site number to the HU and RU before they can be connected to the same CAN network. Use the following procedure to assign a unique site name and number to each HU and RU system: 1. Click on the HOST Config tab and on the REMOTE Config tab. The HOST Config display and the REMOTE Config display will open within the EMS main window as shown in Figure 3-5. 2. Click on the HOST Site Name Edit button (see Figure 3-5). The Site Name pop-up screen will open as shown in Figure 3-6. Enter a unique name for the HOST. The name may be up to 32 characters long and must not contain any spaces. The name may include numbers, punctuation, and upper or lower case letters and must always begin with a letter. Click on OK to close the screen and make the changes take effect. Page 3-9 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Click on the Edit button to open pop-up screen HOST Site Number HOST Site Name REMOTE Site Number (Entered automatically when the HOST site number is selected) REMOTE Site Name Figure 3-5. HOST and REMOTE Config Displays Figure 3-6. HOST Site Name Pop-Up Screen 3. Click on the HOST Site Number Edit button (see Figure 3-5). The Site Number pop-up screen will open. Enter any number (must be unique) between 1 and 24 and then click on OK to close the screen and make the changes take effect. 4. Check the REMOTE Site Number field (see Figure 3-5). The REMOTE Site Number does not have to be entered. When the HOST Site Number is entered, the system will automatically enter the same number for the REMOTE Site Number. 5. Click on the REMOTE Site Name Edit button (see Figure 3-5). The Site Name pop-up screen will open. Enter a unique name for the REMOTE. The name may be up to 32 characters long and must not contain any spaces. The name may include numbers, punctuation, and upper or lower case letters and must always begin with a letter. Click on OK to close the screen and make the changes take effect. 6. Open the Tools menu at the top of the main window and then select Refresh Catalog to make the new Host and Remote site names appear in the View menu. Page 3-10 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 2.3 Reference Procedure: Enter Host Forward Attenuation The HU internal forward path attenuator setting determines the maximum composite output signal level at the RU antenna port. The appropriate attenuation value for any particular system is based on the number of channels the system is transporting and the signal level of the composite forward path signals input at the host units RF IN ports. By default, the forward path attenuator is set to 31 dB. The maximum output power is 38.1 dBm (6.5 Watts) for 800 MHz and 800/900 MHz SMR systems and 38.3 dBm (6.7 Watts) for 1900 MHz systems. The total forward path gain that is provided by the system (with host and remote forward attenuators set to 0 dB) is 77.5 dBm for 800/900 MHz SMR systems, 78.1 for 800 MHz systems, and 78.3 for 1900 MHz systems. For 800/900 MHz SMR systems, this procedure sets the attenuation for both FORWARD RF IN ports. Use the following procedure to set the forward path attenuation to provide the maximum composite output signal level: 1. Click on the HOST RF tab. The HOST RF display will open within the EMS main window as shown in Figure 3-7. Click on Edit button to open Host Fwd Att pop-up screen Figure 3-7. Typical HOST RF Display 2. Click on the Host Fwd Att Edit button (see Figure 3-7). The Host Fwd Att pop-up screen will open as shown in Figure 3-8. 3. Obtain the value of the total composite input signal level as determined in step 11 of Section 2.1. Page 3-11 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Figure 3-8. Host Fwd Att Pop-Up Screen 4. Determine the appropriate value to enter for the Host forward path attenuator by subtracting the required system output level (per system design plan) from the system gain (77.5 dB for 800/900 MHz SMR, 78.1 dB for 800 MHz, and 78.3 dB for 1900 MHz) and then adding the composite input signal level. The result (see sample calculation) is the amount of attenuation required. Atten = (System Gain) – (Required System Output Power) + (Composite Input Power) 5. Enter the attenuation value and click OK to close the pop-up screen and to make the changes take effect. 2.4 Reference Procedure: Determine Output Signal Level at RU Antenna Port The RF output signal level should be measured at the RU ANTENNA port to verify that the composite signal level is at the expected level. Use the following procedure to determine the power level: Note: The RF output signal level measured in this procedure should be approximately 31 dBm less than the output level specified for operation. This is because the factory default setting for the remote forward attenuator is 31 dB. The final adjustment of the system RF output signal level will be completed in Section 2.5 1. Place the AC circuit breaker switch (at the RU power panel) in the open (OFF) position. 2. Disconnect the antenna cable from the RU ANTENNA port. 3. Connect a spectrum analyzer or RF power meter to the HU ANTENNA port. (Check the input rating of the test equipment. Insert a 30 dB 100 W attenuator if necessary.) 4. Place the AC circuit breaker switch (at the RU power panel) in the closed (ON) position. 5. If using a spectrum analyzer, proceed to step 6. If using a power meter, measure the composite signal power from the RU and then proceed to step 8. 6. Measure the RF level of a single carrier, such as the control channel, in dBm. Make sure the resolution bandwidth of the spectrum analyzer is 30 kHz. Page 3-12 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 7. Calculate the total composite signal power using the following formula: Ptot = Pc + 10Log N Where, Ptot is the total composite power in dBm Pc is the power per carrier in dBm as measured in step 6, and N is the total number of channels. 8. Record the result measured in step 5 or calculated in step 7. 9. Place the AC circuit breaker switch (at the RU power panel) in the open (OFF) position. 10. Disconnect the spectrum analyzer or RF power meter from the HU ANTENNA port. 11. Re-connect the antenna cable to the HU ANTENNA port. Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. 12. Place the AC circuit breaker switch (at the RU power panel) in the closed (ON) position. 2.5 Reference Procedure: Enter Remote Forward Attenuation The RU internal forward path attenuator setting is used to reduce the power level of the composite output signals at the RU. The maximum composite output signal level at the RU antenna port is set using both the HU forward attenuator (see Section 2.3) and the RU forward attenuator. Component variations may result in the output power at the HU antenna port being slightly above or below the calculated value. The RU forward attenuator is used in conjunction with the HU forward attenuator to add or remove attenuation to produce the required output signal level at the antenna port. The default setting for the RU forward attenuator is 31 dB. Use the following procedure to change the RU forward attenuation: Caution: The RU may be destroyed if the maximum recommended output signal level at the RU antenna port is exceeded. Make sure that sufficient attenuation is inserted in the forward path to prevent the RU from being overdriven. 1. Click on the REMOTE RF tab. The REMOTE RF display will open within the EMS main window as shown in Figure 3-9. 2. Check the level of the RF output signal (as determined in Section 2.4) against the system design plan specifications. The maximum output signal level permitted is 38.1 dBm (6.5 Watts) for both 800 MHz and 800/1900 MHz SMR systems; and 38.3 dBm (6.7 Watts) for 1900 MHz systems. 3. Determine if more or less attenuation is required to produce the required output signal level. 4. Click on the Remote Fwd Att field Edit button (see Figure 3-9). The Remote Fwd Att pop-up screen will open as shown in Figure 3-10. Page 3-13 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Click Edit button to open the Remote Fwd Att pop-up screen RF output signal level (± 3 dB) Figure 3-9. Typical REMOTE LPA Display Figure 3-10. Remote Fwd Att Pop-Up Screen 5. Enter the required attenuation value and click OK to close the pop-up screen and to make the changes take effect. 6. Verify that the appropriate RF output signal level appears in the RF Output Power field (see Figure 3-9). This is primarily a reference value and should not take the place of external test equipment when determining the power level of the composite RF output signal. Depending on the modulation type and number of channels, the EMS software may report a power level that is higher or lower (± 3 dB) than the actual RF output signal. Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. Page 3-14 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 2.6 Reference Procedure: Enter Host Reverse Attenuation The level of the RF signal that should be input to the EBTS will vary depending on the type of EBTS, the receive distribution, and the number of channels present. To interface with the EBTS, the reverse path signal level must be adjusted to provide the signal level required at the EBTS input port(s). The HU provides from –1 to +30 dB of gain in the reverse path. By default, the host reverse attenuator is set to –31 dB of attenuation which provides –1 dB of gain. Use the following procedure to set the reverse path gain: 1. Check the EBTS manufacturer’s specifications to determine the composite signal level required at the reverse path input port(s). Note that 800/900 MHz SMR host units have two reverse path input ports. 2. Determine the overall gain and loss imposed on the signal by the antenna, antenna cable, and by the cables that connect the HU to the EBTS. 3. Determine the amount of gain required to raise the reverse path signal to the level required at the EBTS. 4. Click on the HOST RF tab. The HOST RF display will open within the EMS main window as shown in Figure 3-11. Click Edit button to open the Host Rev Att pop-up screen Figure 3-11. Typical HOST RF Display 5. Click on the Host Rev Att field Edit button (see Figure 3-11). The Host Rev Att pop-up screen will open as shown in Figure 3-12. Page 3-15 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Figure 3-12. Host Rev Att Pop-Up Screen 6. Enter the attenuation value that will provide the required gain. Refer to Table 3-2 for the attenuation values and the corresponding gain (nominal) values. 7. Click OK to close the pop-up screen and to make the changes take effect. Table 3-2. Reverse Path Attenuation Setting and Nominal Gain Provided ATTENUATION SETTING 2.7 GAIN PROVIDED ATTENUATION SETTING GAIN PROVIDED ATTENUATION SETTING GAIN PROVIDED 0 dB → 30 dB 11 dB → 19 dB 22 dB → 8 dB 1 dB 29 dB 12 dB 18 dB 23 dB 7 dB 2 dB 28 dB 13 dB 17 dB 24 dB 6 dB 3 dB 27 dB 14 dB 16 dB 25 dB 5 dB 4 dB 26 dB 15 dB 15 dB 26 dB 4 dB 5 dB 25 dB 16 dB 14 dB 27 dB 3 dB 6 dB 24 dB 17 dB 13 dB 28 dB 2 dB 7 dB 23 dB 18 dB 12 dB 29 dB 1 dB 8 dB 22 dB 19 dB 11 dB 30 dB 0 dB 9 dB 21 dB 20 dB 10 dB 31 dB –1 dB 10 dB 20 dB 21 9 dB Reference Procedure: Enter Host Forward and Reverse Delay The forward and reverse delay function allows entry of from 0 to 63 µsec of delay in the forward and reverse paths. This feature is used when multiple systems are used to transport the same channel and there is a significant difference in the path delay between systems. Additional delay may be entered to balance the overall system delay. The amount of delay required must be calculated by the RF engineer and should be included in the system design plan. The default setting is 0 µsec. Use the following procedure to change the forward and reverse path delay: Page 3-16 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION 1. Click on the HOST RF tab. The HOST RF display will open within the EMS main window as shown in Figure 3-13. Click Edit button to open the Host Fwd Delay pop-up screen Click Edit button to open the Host Rev Delay pop-up screen Figure 3-13. Typical HOST RF Display 2. Click on the Host Fwd Delay field Edit button (see Figure 3-13). The Host Fwd Delay pop-up screen will open as shown in Figure 3-14. Figure 3-14. Host Fwd Delay Pop-Up Screen 3. Obtain the value of the forward delay as specified in the system design plan. The delay is adjustable in 0.1 µsec steps. 4. Enter the forward path delay value and click OK to close the pop-up screen and to make the changes take effect. 5. Repeat the process for reverse delay by right-clicking on the appropriate delay section (see Figure 3-13) and then entering the required delay value in the pop-up screen. 6. Click OK to close each pop-up screen and to make the changes take effect. Page 3-17 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 3: OPERATION Blank Page 3-18 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE SECTION 4: MAINTENANCE Content Page SYSTEM MAINTENANCE OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 FAULT DETECTION AND ALARM REPORTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2 FAULT ISOLATION AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 1.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 3.1 Host Unit Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 3.2 RU Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 TEST PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 4.1 Optical Power Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 4.2 Optical Loopback Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 SCHEDULED MAINTENANCE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 _________________________________________________________________________________________________________ SYSTEM MAINTENANCE OVERVIEW This section explains the Digivance system fault detection and alarm reporting system, provides a method for isolating and troubleshooting faults, and provides test procedures. The Digivance system requires minimal regular maintenance to insure continuous and satisfactory operation. The only components that require regular replacement are the HU cooling fans. Maintenance also includes diagnosing and correcting service problems as they occur. When an alarm is reported, it will be necessary to follow a systematic troubleshooting procedure to locate the problem. Once the source of the problem is isolated, the appropriate corrective action can be taken to restore service. The only internal components that can be replaced are the cooling fans that mount in the HU. The failure of any other internal component will require replacement of the entire unit. 1.1 Tools and Materials The following tools and materials are required in order to complete the maintenance procedures specified in this section: • • • • IR filtering safety glasses Patch cords with SC connectors 15 dB in-line SC optical attenuators Optical power meter (1550 and 1310 nm) Page 4-1 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE FAULT DETECTION AND ALARM REPORTING The Digivance LRCS on-board embedded software detects various unit and system faults which generate ether a Major or Minor alarm. A Major alarm indicates that the system has failed in a way that directly affects RF transport performance. When a major alarm occurs, all RF functions are disabled and the system is out of service. A Minor alarm means that system performance is not affected or in some cases, that the performance may no longer be optimal. When a minor alarm occurs, RF functions continue and the system remains in service. The following means are used to report Major and Minor alarms: • HU alarm contacts • HU and RU LED’s • EMS software Graphical User Interface (GUI) • Network Operations Center - Network Element Manager (NOC/NEM) interface • SNMP interface The HU is equipped with a set of both normally open (NO) and normally closed (NC) alarm contacts which may be used to report both Major and Minor alarms to an external alarm system. The alarm contacts summarize the inputs so that any Major or Minor alarm will trigger an alarm report to the external alarm system. The HU is equipped with multiple front panel LED indicators that show status and alarm information by displaying various colors: Green, Red, Yellow, and Off. The RU is equipped with a single LED indicator that shows status and alarm information by displaying either Red or Off. A detailed description of the Host Unit and Remote Unit LED indicators is provided respectively in Table 4-1 and Table 4-2. The EMS software GUI provides both a summary and a detailed list of alarm information that includes unit and module level faults, circuit faults, and measured value faults such as voltages, RF power, and temperature. A summary showing a list of all systems and their current alarm status is presented through the Alarm OverView display. A more detailed list of alarm information is presented through the HOST alarm display and the REMOTE alarm display. The various fault conditions that trigger a major or minor alarm report are shown in the HOST and REMOTE alarm displays. The NOC/NEM interface provides the same summary and detailed listing of alarm information as the EMS software GUI but in an ASCII text string format. Sending the command GET ALARMSUMMARY produces a list of all systems and their current alarm status. Sending the command GET ALARM ALL for a specific system will produce a detailed list of alarm information for the specified system. The SNMP interface provides alarm information to up to ten SNMP managers which must be registered with the SNMP agent. The SNMP interface allows the SNMP managers to receive the alarm and status information generated by the host and remote units. The presentation of the alarm information is dependent on the features of the SNMP manager. Page 4-2 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-1. Host Unit LED Indicators INDICATOR COLOR DESCRIPTION Green Off Indicates if the HU is powered or un-powered. The DC power source is on. The DC power source is off. POWER STANDBY Indicates if the system is in the standby, normal, test, or program load mode. Green (blinking) The HU is in the standby mode. Yellow (blinking) The HU is in the program load mode. The HU is in the test mode. Red (blinking) The HU is in the normal mode. Off Green Yellow Red Indicates if the HU is normal, over temperature, if an internal fault is detected, or if there is an equipment mismatch. The HU is normal. The HU is over temperature or detects an internal fault. The HU detects an internal fault or HU/RU band mismatch. Green Yellow Red Indicates if an alarm is detected at the RU. No alarms detected at the RU. A minor alarm is detected at the RU. A major alarm is detected at the RU. HOST UNIT REMOTE UNIT DRIVE 851–869 DRIVE 935–940 (Rear Access HU) Green Yellow DRIVE (Front Access HU) Red FWD/REV (PORT 1/PORT 2) Green Red Indicates if the specified forward path RF signal level is normal, above overdrive threshold, or below underdrive threshold. The RF signal level is normal The RF signal level is below the underdrive threshold. The RF signal level is above the overdrive threshold. Indicates if the reverse path optical signals from the RU are normal, if errors are detected, or if the optical signal is not detected. The reverse path optical signals are normal. Excessive errors (see Note) are detected in the reverse path optical signals or the HU is not receiving a reverse path optical signal. Note: Excessive errors means the Bit Error Rate (BER) has exceeded 10–6 (1 bit error per million bits). Table 4-2. Remote Unit LED Indicator INDICATOR COLOR STATUS Off Red DESCRIPTION Indicates if the RU is unpowered, normal, or if an internal fault is detected. The RU is unpowered or the RU is normal and no faults are detected. The RU detects an internal fault, excessive errors (see Note) are detected in the forward path optical signals, or the RU is not receiving a forward path optical signal. Note: Excessive errors means the Bit Error Rate (BER) has exceeded 10–6 (1 bit error per million bits). Page 4-3 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE FAULT ISOLATION AND TROUBLESHOOTING Alarm information may be accessed using the HU and RU LED indicators, the EMS software GUI, the NOC-NEM interface, or the SNMP manager. When an alarm occurs, use the unit LED indicator(s) and any one of the specified software tools to determine which Digivance system is affected, which unit (HU or RU) reported the alarm, and the fault that generated the alarm. Then refer to either Section 3.1 Host Unit Troubleshooting or Section 3.2 RU Troubleshooting to isolate the problem and to determine the corrective action required. When attempting to isolate a problem, always determine the initial fault that generated the alarm report. Some faults may cause additional faults to be reported which tends to obscure the initial reason for the alarm. To help isolate faults, the EMS GUI provides an AlarmOverview screen, shown in Figure 4-1, that indicates which Digivance system/unit is reporting the alarm. Click to acknowledge alarm and to open Alarm History Info dialog box Click to clear alarm history fault indicator and to close Alarm History Info dialog box Figure 4-1. AlarmOverView Screen The AlarmOverview screen includes an ALARM HIST indicator which the user should click to acknowledge that an alarm exists. Acknowledging the alarm opens the Alarm History Info dialog box (also shown in Figure 4-1) which directs the user to view the EMS Log file for details. The EMS Log file lists the various faults in the order in which they occurred. Clear each fault starting with the initial fault. In most instances, clearing the initial fault will also clear any remaining faults. For additional information on using the AlarmOverview screen, refer to the Digivance Element Management System User Manual (see Related Publications section). Note: It is recommended that if there are alarms at both the HU and RU, the optical faults should be checked and cleared first. Because the HU and RU function as a system, a fault in the fiber optic link will cause alarms to be reported by both the HU and RU. Page 4-4 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE 3.1 Host Unit Troubleshooting Use this section to troubleshoot alarms that originate with the Host Unit. When a Minor alarm occurs, one (or more) of the Host Unit LED’s with turn yellow and the EMS software will indicate a minor fault/alarm. When a Major alarm occurs, one (or more) of the Host Unit LED’s will turn red and the EMS software will report a major fault/alarm. Locate the LED and the corresponding software fault/status indicator in Table 4-3 and then take the corrective action indicated. Table 4-3. Host Unit Fault/Alarm Isolation Diagram Host Unit Front Panel LED Software Fault/Status Indicator Corrective Action or Reference Green - Powered Power Off - Not powered No specific HU faults - Only faults with no associated LED are displayed Table 4-5 Problem A Green blinking - Standby Yellow blinking Program load Standby Red blinking - Test Use EMS to change system to required mode Oper Mode - Operational mode of system Off - Normal Green - Normal Yellow - Minor Alarm Temperature - Over temperature Table 4-5 Problem B Fwd Synth Lock - Forward synthesizer out of lock Host Unit LO Synth Lock - Local oscillator synthesizer out of lock Pri Rev Synth Lock - Reverse primary synthesizer out of lock 8 Volt - Onboard 8 Volt power supply below threshold Red - Major Alarm Replace HU 3.8 Volt - Onboard 3.8 Volt power supply below threshold Pri Fwd Mux Lock - Forward primary phase locked loop out-of-lock Pri Laser Fail - Forward primary laser failure Hardware mismatch - Host and Remote band mismatch Reverse Link Fault Replace HU or RU with correct unit Table 4-5 Problem G Green - Normal Remote Unit Yellow - Minor Alarm at Remote Unit - See Table 4-5. Remote Unit Fault/Alarm Isolation Diagram Red - Major Alarm at Remote Unit - See Table 4-5. Remote Unit Fault/Alarm Isolation Diagram Continued 20013-B Page 4-5 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-3. Host Unit Fault/Alarm Isolation Diagram, continued Host Unit Front Panel LED Software Fault/Status Indicator Green - Normal Drive (FRONT ACCESS) Corrective Action or Reference Yellow - Minor Alarm RF Underdrive - Forward path RF signal level too low Table 4-4 Problem C Red - Major Alarm RF Overdrive - Forward path RF signal level too high Table 4-4 Problem D Yellow - Minor Alarm RF Underdrive 800 MHz - 800 MHz forward path RF signal level too low Table 4-4 Problem C Red - Major Alarm RF Overdrive 800 MHz - 800 MHz forward path RF signal level too high Table 4-4 Problem D Green - Normal Drive 851-869 (REAR ACCESS) Fwd/Rev (Port 1/Port 2) Green - Normal Pri Rx Light - No light received over optical reverse path See Table 4-4 Problem E Red - Major Alarm Pri Rx Errors - Excessive errors received over optical reverse path See Table 4-4 Problem E Yellow - Minor Alarm RF Underdrive 900 MHz - 900 MHz forward path RF signal level too low Table 4-4 Problem C Red - Major Alarm RF Overdrive 900 MHz - 900 MHz forward path RF signal level too high Table 4-4 Problem D Green - Normal Drive 935-940 (REAR ACCESS) Minor Contact Output - Minor alarm reported by HU or STM Major Contact Output - Major alarm reported by HU or STM See specific fault indicator See specific fault indiator No Associated LED Remote Lost - The HU cannot communicate with remote (STM) EMS Link Status - The EMS cannot communicate with HU See Table 4-4 Problem E See Table 4-4 Problem F 20583-A Table 4-4. Host Unit Fault/Alarm Corrective Action PROBLEM A: The HU is not powered. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The HU is turned off. 2. The fuse is open/removed from the fuse panel or the DC power has failed. 1. Place On/Off switch in the On position. 2. Check DC power source, repair as needed, and replace or reinstall fuse at fuse panel. PROBLEM B: The HU is overheating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Air intake or exhaust opening to HU chassis is blocked 2. Ambient temperature > 50º C/122º F. 3. Faulty fan. 4. The HU has failed. 1. Remove cause of air-flow blockage. Page 4-6 © 2005, ADC Telecommunications, Inc. 2. Reduce ambient temperature. 3. Replace HU fan (See applicable manual). 4. Replace HU. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-4. Host Unit Fault/Alarm Corrective Action, continued PROBLEM C: The RF input signal level is below the underdrive threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Composite output signal from EBTS is too low. 1. Check EBTS composite output signal level and adjust if too low. 2. Correct EBTS cables if faulty. 2. Faulty coaxial connection between the HU and the EBTS. 3. Check Host Forward Attenuator setting and 3. Incorrect attenuation in forward path RF adjust if attenuation is too high. coaxial link. PROBLEM D: The RF input signal is above the overdrive threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Composite output signal level from EBTS is too high. 2. Incorrect attenuation in forward path RF coaxial link. 1. Check EBTS composite output signal level and adjust if too high. 2. Check Forward Attenuator setting and adjust if attenuation is too low. PROBLEM E: No light received over the reverse path or excessive errors received over the reverse path POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty reverse path optical fiber. 1. Test optical fiber. Clean connector if dirty. Repair or replace optical fiber if faulty. (See Section 4.1). 2. Test optical ports. Replace HU or RU if port is faulty (See Section 4.2). 2. Faulty optical transmit port at the RU; or faulty optical receive port at the HU PROBLEM F: The HU does not respond to control or monitoring commands sent by the EMS. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. See Problem A this table. 1. The HU is not powered. 2. The cable connection between the HU and the 2. Inspect EMS cable and repair or replace if faulty. EMS computer is faulty. 3. The CAN cable connections between the HUs 3. Inspect each CAN cable and repair or replace if faulty. in a multiple HU installation are faulty. PROBLEM G: There is a loss of gain in either the primary or diversity reverse path of 10 dBm or greater. 3.2 POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The HU has failed. 2. The RU has failed 1. Replace the HU. 2. Replace the RU. RU Troubleshooting Use this section to troubleshoot alarms that originate with the RU. When a Minor or Major alarm occurs, the RU STATUS LED will turn red and the EMS software will indicate a minor or major fault/alarm. Use the EMS software to identify the fault and then refer to Table 4-5 to determine the corrective action required. Page 4-7 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-5. Remote Unit Fault/Alarm Isolation Diagram Remote Unit LED Software Fault/Status Indicator Corrective Action or Reference Off - Not powered or Normal No Response for Minor Alarm Temperature - Over temperature See Table 4-6 Problem A Converter - Power supply converter failure LO Synth Lock - Local oscillator synthesizer out of lock Fwd Synth Lock - Forward synthesizer out of lock Pri Rev Synth Lock - Reverse primary synthesizer out of lock One LED, no designation Ref Synth Lock - Reference synthesizer out of lock 8 Volt - Onboard 8 Volt power supply below threshold Replace RU 3.8 Volt - Onboard 3.8 Volt power supply below threshold Pri Rev Mux Lock - Reverse primary phase locked loop out-of-lock Pri Laser Fail - Reverse primary laser failure Red - Major Alarm LPA DC Fail - LPAa power supply failure LPA Loop Fail - LPA internal loop failure LPA Low Power - LPA internal amplifier failure LPA Temp - LPA over temperature See Table 4-6 Problem A LPA Over Power - LPA signal level too high See Table 4-6 Problem B LPA VSWR - The LPA VSWR is too high See Table 4-6 Problem C System VSWR - The VSWR at the quadraplexer is too high See Table 4-6 Problem D Pri Rx Light - No light received over optical forward path See Table 4-6 Problem E Pri Errors - Excessive errors received over optical forward path See Table 4-6 Problem E Hardware mismatch - Host and Remote band mismatch Replace HU or RU with correct unit Continued Page 4-8 © 2005, ADC Telecommunications, Inc. 20584-B ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-5. Remote Unit Fault/Alarm Isolation Diagram, continued Remote Unit LED Software Fault/Status Indicator Corrective Action or Reference Host Lost - The STM cannot communicate with Host (HU) See Table 4-6 Problem E EMS Link Status - The EMS cannot communicate with STM See Table 4-6 Problem F RF Power - No RF power detected at quadraplexer (STM) See Table 4-6 Problem G LPA Disable - The LPA is shut down See Table 4-6 Problem H No Associated LED 20585-A Table 4-6. Remote Unit Fault/Alarm Corrective Action PROBLEM A: The RU (STM or LPA) is overheating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Debris preventing air from freely circulating around the RU aluminum enclosure. 2. Ambient temperature > 50º C/122º F. 3. The RU has failed. 1. Remove cause of air-flow blockage. 2. Reduce ambient temperature. 3. Replace RU. PROBLEM B: The output power from the LPA exceeds the maximum rating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The power level of the RF forward path composite input signal at the HU is too high. 1. Check the power level of the RF composite input signal at the HU and adjust to correct level. To reset, use EMS to place Digivance system in standby mode and then place system back in normal mode. 2. Replace RU. 2. The RU (LPA) has failed. PROBLEM C: The VSWR at the LPA exceeds the threshold setting of 3:1. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The antenna cable or antenna cable connectors 1. Inspect antenna cable and connectors and repair are faulty. or replace as needed.To reset, use EMS to place Digivance system in standby mode and then place system back in normal mode. 2. The antenna or antenna system is faulty. 3.The RU qudraplexer or LPA has failed. 2. Check the antenna circuit for shorts or opens (including lightning protector). To reset, use EMS to place Digivance system in standby mode and then place system back in normal mode. 3. Replace RU. Page 4-9 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE Table 4-6. Remote Unit Fault/Alarm Corrective Action, continued PROBLEM D: The forward path VSWR is above threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty antenna or antenna system. 1. Check the antenna system for shorts or opens (including lightning protector). To reset, use EMS to place Digivance system in standby mode and then place system back in normal mode. 2. Check the antenna cable for faulty connections. 3. Replace the RU. 2. Faulty antenna cable. 3. The RU qudraplexer has failed. PROBLEM E: No light received over the forward path or excessive errors received over the forward path POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty forward path optical fiber. 1. Test optical fiber. Clean connector if dirty. Repair or replace optical fiber if faulty. (See Section 4.1). 2. Test optical ports. Replace HU or RU if port is faulty (see Section 4.2). 2. Faulty optical transmit port at the HU; or faulty optical receive port at the RU. PROBLEM F: The RU does not respond to control or monitoring commands sent by the EMS. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The cable connection between the HU and the EMS computer is faulty. 1. Inspect EMS cable and repair or replace if faulty. PROBLEM G: No RF power is detected at the RU quadraplexer. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. No RF power is being input to the HU or the RF input signal level at the HU is too low. 2. The RU (LPA) is faulty. 1. Check the RF input power level at the HU and adjust until within specifications. 2. Replace RU. PROBLEM H: The RF output form the RU (LPA) is shut down. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The LPA is in the forced shutdown mode. 1. Check for fault conditions that will cause a major alarm. Correct faults as required. To reset, use EMS to place Digivance system in standby mode and then place system back in normal mode 2. Replace RU. 2. The RU (LPA) is faulty. Page 4-10 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE TEST PROCEDURES This section provides procedures for common troubleshooting and maintenance tests. Refer to these procedures as needed when specified in the Fault/Alarm Isolation Diagrams in Section 3. 4.1 Optical Power Test A break in an optical fiber or a fault with the optical connector will interrupt communications between linked components or generate excessive errors. Use the following procedure to isolate a problem with an optical fiber or connector. Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. 1. Put on the IR filtering safety glasses. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. At the HU, place the On/Off switch in the OFF position (press O). At the RU, place the AC circuit breaker switch in the open (OFF) position. Note: Turning off the HU and RU disables the respective lasers which is necessary in order to safely inspect and clean the optical connectors. 4. Disconnect the optical fiber connectors for the fiber to be tested at the HU and the RU. 5. Inspect the optical connectors. Verify that connectors are clean and that no scratches or imperfections are visible on the fiber end. Clean and polish the optical connectors if necessary. 6. Connect the optical power meter to the output (receiver) end of the optical fiber as shown in Figure 4-2. If an attenuator was included in the fiber link, make sure it is installed. HOST UNIT FWD (PORT 1) REV (PORT 2) WDM FORWARD PATH OPTICAL FIBER TEST SET UP FWD/REV PATH OPTICAL FIBER OPTICAL POWER METER ATTENUATOR (IF USED) -15 TO -25 dBm REMOTE UNIT OPTICAL POWER METER REVERSE PATH OPTICAL FIBER TEST SET UP BAND 2 ATTENUATOR (IF USED) -15 TO -25 dBm 3 WDM FWD/REV PATH OPTICAL FIBER BAND 1 20979-A SEE TAG ON PORT TO IDENTIFY SYSTEM Figure 4-2. Forward and Reverse Path Optical Fiber Test Set Up Page 4-11 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE 7. Connect the input (transmitter) end of the optical fiber to the transmitting HU or RU. 8. If the transmitting unit is the HU, place the On/Off switch in the ON position (press I). If the transmitting unit is the RU, close (turn on) the AC circuit breaker switch. 9. Using the transmitting HU or RU as an optical light source, measure the optical power at the receiver end of the optical fiber. The power level of the optical signal received at the HU or RU should be –15 to –25 dBm (with attenuator installed). If the power level of the received optical signal is within this range, the optical fiber and the far end unit are good. If the power level of the signal is greater than –15 dBm, insert additional attenuation to bring the signal level within the specified range. If the power level is less than –25 dBm, the value of the external attenuator is too high, the optical fiber is faulty, or the far end unit optical transmitter is faulty. Continue with test procedure to isolate the problem Caution: Erratic operation may occur with an optical input signal level of –13 dBm or higher. If the optical input signal level exceeds –9 dBm, the optical receiver may be damaged. 10. If the transmitting unit is the HU, place the On/Off switch in the OFF position (press O). If the transmitting unit is the RU, open (turn off) the AC circuit breaker switch. 11. Disconnect the optical power meter from the receiver end of the optical fiber. 12. Use a 1 meter patch cord to connect the optical power meter to the transmitting HU or RU as shown in Figure 4-3. HOST UNIT FWD (PORT 1) HOST UNIT OPTICAL TRANSMITTER TEST SET UP OPTICAL POWER METER REV (PORT 2) 1 METER PATCH CORD 0 +/- 1 dBm REMOTE UNIT OPTICAL TRANSMITTER TEST SET UP OPTICAL POWER METER REMOTE UNIT BAND 2 BAND 1 20980-A 1 METER PATCH CORD +1.3 +/- 1 dBm SEE TAG ON PORT TO IDENTIFY SYSTEM Figure 4-3. Host Unit and Remote Unit Optical Transmitter Test Set Up 13. If the transmitting unit is the HU, place the On/Off switch in the ON position (press I). If the transmitting unit is the RU, close (turn on) the AC circuit breaker switch. 14. Measure the optical output power of the transmitting HU or RU. The power level of the optical output signal from the HU or RU must meet the following specification: Forward Path Signal at the HU: 0 + 1 dBm Reverse Path Signal at the RU: +1.3 + 1 dBm If the power level of the optical output signal is within specifications with a 1 meter patch cord installed, the fiber optic link is faulty. If the power level of the optical signal is not within specifications, the far end HU or RU optical transmitter is faulty. Page 4-12 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE 15. If the transmitting unit is the HU, place the On/Off switch in the OFF position (press O). If the transmitting unit is the RU, open (turn off) the AC circuit breaker switch. 16. Disconnect the optical power meter from the receiver end of the optical fiber. 17. Reconnect the optical fibers to the receiving HU or RU. 18. Repeat steps 3 through 17 for each optical fiber that requires testing. 19. When ready to put the system back into service, place the On/Off switch on the HU in the ON position (press I) and close (turn on) the AC circuit breaker switch for the RU. 20. Notify the NOC or alarm monitoring service that the system is going back online. 4.2 Optical Loopback Test The following procedure provides a test to determine if an optical port fault exists with the Host Unit. Note: Because the RU is equipped with a WDM, the optical loopback test cannot be performed on the RU. Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. 1. Put on the IR filtering safety glasses. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. Place the On/Off switch in the OFF position (press O). 4. Disconnect the optical fiber connectors from the FWD (PORT 1) and REV (PORT 2) optical ports and place a dust cap over each connector. 5. Plug a 15 dB in-line optical attenuator into the FWD (PORT 1) optical port as shown in Figure 4-4. Caution: The optical receiver can be damaged if the power level of the optical input signal is too high. To avoid damaging the optical receiver when performing the loopback test, always install a 15 dB in-line attenuator in the optical receiver circuit. 6. Connect a 1 meter patch cord between the optical attenuator and the REV (PORT 2) optical port. 7. Place the On/Off switch in the ON position (press I). Page 4-13 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 4: MAINTENANCE HOST UNIT FWD (PORT 1) REV (PORT 2) 20019-C 15 dB ATTENUATOR 1 METER PATCH CORD Figure 4-4. Host Unit Loopback Test 8. Observe the FWD/REV (PORT 1/PORT 2) LED indicator which will turn either red or green. If the LED turns red, either the FWD (PORT 1) optical transmitter or the REV (PORT 2) receiver is faulty. If the LED turns green, both the FWD (PORT 1) and the REV (PORT 2) optical ports are good. 9. Place the On/Off switch in the OFF position (press O). 10. Remove the dust caps from the optical fiber connectors. 11. Clean each connector (follow connector supplier’s recommendations) and then insert each connector into the appropriate optical port. 12. When ready to put the HU back into service, place the On/Off switch in the ON position (press I). 13. Notify the NOC or alarm monitoring service that the system is going back online. SCHEDULED MAINTENANCE REQUIREMENTS The only scheduled maintenance required for the SCS system is to remove and replace the HU cooling fans. This should be done at 60 month intervals. Refer to the applicable Digivance LRCS Host Unit Installation and Maintenance Manual (See Related Publications section) for the procedure. Page 4-14 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 5: GENERAL INFORMATION SECTION 5: GENERAL INFORMATION Content Page WARRANTY/SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 SOFTWARE SERVICE AGREEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 REPAIR/EXCHANGE POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 REPAIR CHARGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 REPLACEMENT/SPARE PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 RETURNED MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 _________________________________________________________________________________________________________ WARRANTY/SOFTWARE The Product and Software warranty policy and warranty period for all ADC Products is published in ADC’s Warranty/Software Handbook. Contact the Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada) for warranty or software information or for a copy of the Warranty/Software Handbook. SOFTWARE SERVICE AGREEMENT ADC software service agreements for some ADC Products are available at a nominal fee. Contact the Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada) for software service agreement information. REPAIR/EXCHANGE POLICY All repairs of ADC Products must be done by ADC or an authorized representative. Any attempt to repair or modify ADC Products without written authorization from ADC voids the warranty. If a malfunction cannot be resolved by the normal troubleshooting procedures, call the Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada). A telephone consultation can sometimes resolve a problem without the need to repair or replace the ADC Product. If, during a telephone consultation, ADC determines the ADC Product needs repair, ADC will authorize the return of the affected Product for repair and provide a Return Material Authorization number and complete return shipping instructions. If time is critical, ADC can arrange to ship the replacement Product immediately. In all cases, the defective Product must be carefully packaged and returned to ADC. Page 5-1 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 5: GENERAL INFORMATION REPAIR CHARGES If the defect and the necessary repairs are covered by the warranty, and the applicable warranty period has not expired, the Buyer’s only payment obligation is to pay the shipping cost to return the defective Product. ADC will repair or replace the Product at no charge and pay the return shipping charges. Otherwise, ADC will charge a percentage of the current Customer Product price for the repair or NTF (No Trouble Found). If an advance replacement is requested, the full price of a new unit will be charged initially. Upon receipt of the defective Product, ADC will credit Buyer with 20 percent of full price charged for any Product to be Out-of-Warranty. Products must be returned within thirty (30) days to be eligible for any advance replacement credit. If repairs necessitate a visit by an ADC representative, ADC will charge the current price of a field visit plus round trip transportation charges from Minneapolis to the Buyer’s site. REPLACEMENT/SPARE PRODUCTS Replacement parts, including, but not limited to, button caps and lenses, lamps, fuses, and patch cords, are available from ADC on a special order basis. Contact the Technical Assistance Center at 1-800-366-3891, extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada) for additional information. Spare Products and accessories can be purchased from ADC. Contact Sales Administration at 1-800-366-3891, extension 73000 (in U.S.A. or Canada) or 1-952-938-8080 (outside U.S.A. and Canada) for a price quote and to place your order. RETURNED MATERIAL Contact the ADC Product Return Department at 1-800-366-3891, extension 73748 (in U.S.A. or Canada) or 952-917-3748 (outside U.S.A. and Canada) to obtain a Return Material Authorization number prior to returning an ADC Product. All returned Products must have a Return Material Authorization (RMA) number clearly marked on the outside of the package. The Return Material Authorization number is valid for 90 days from authorization. Page 5-2 © 2005, ADC Telecommunications, Inc. ADCP-75-187 • Preliminary Issue 1B • November 2005 • Section 5: GENERAL INFORMATION CUSTOMER INFORMATION AND ASSISTANCE PHONE: EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 U.S.A. OR CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Connectivity Extension 73475 Wireless Extension 73476 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-938-8080 Technical Assistance: +1-952-917-3475 WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE 189702. ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: connectivity.tac@adc.com wireless.tac@adc.com euro.tac@adc.com 13944-M asiapacific.tac@adc.com Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. © 2005, ADC Telecommunications, Inc. All Rights Reserved Printed in U.S.A Page 5-3 Blank www.adc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2007:05:07 07:57:47-05:00 Create Date : 2007:05:07 07:57:36-05:00 Metadata Date : 2007:05:07 07:57:47-05:00 Creator Tool : FrameMaker 6.0 Format : application/pdf Title : 75187.book Document ID : uuid:fdd61c53-5524-4df3-826b-cc2092a19ba1 Instance ID : uuid:1edb7711-3e62-4252-9720-5c51167642e9 Producer : Acrobat Distiller 4.05 for Windows Page Count : 49 Creator : FrameMaker 6.0EXIF Metadata provided by EXIF.tools