ADC Telecommunications S2785-011 800/900 MHz SRAU User Manual Spectrum
ADC Telecommunications Inc. 800/900 MHz SRAU Spectrum
Users Manual
ADC Spectrum 7.0 Installation Guide ADCP-77-xxx Issue 1 12/2009 D-xxxxxx-x-xx Rev A Copyright © 2009 ADC Telecommunications, Inc. All Rights Reserved. Information contained in this document is company private to ADC Telecommunications, Inc. and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. Trademark Information ADC is a registered trademark and FlexWave and Universal Radio Head are trademarks of ADC Telecommunications, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. Other product names mentioned in this practice are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Disclaimer of Liability Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Specific Disclaimer for High-Risk Activities This Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. ADC (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes. Screenshots in User Documentation Due to concurrent development of this documentation, artwork, and the FlexWave URH EMS product, there may be some minor discrepancies between screenshots contained in this documentation and those actually displayed in the FlexWave URH EMS. These discrepancies will generally be few and minor and should not affect your understanding of FlexWave URH EMS. ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 917-1717 TABLE OF CONTENTS Preface.................................................................................................................... 2 Revision History................................................................................................... 2 Document Cautions and Notes ............................................................................... 2 General Safety Precautions ................................................................................... 2 Standards Certification ......................................................................................... 3 Introduction ............................................................................................................. 4 Host Unit ............................................................................................................ 5 DART Remote Unit ............................................................................................... 6 IF Expansion Unit................................................................................................. 7 Main Remote Access Unit ...................................................................................... 8 Secondary Remote Access Unit .............................................................................. 9 Omni Antenna ................................................................................................... 10 Installation ............................................................................................................ 11 Cascading.............................................................................................................. 14 Specifications ......................................................................................................... 15 Contacting ADC ...................................................................................................... 17 Preface PREFACE This manual provides basic installation instructions for a ADC® Spectrum 7.0 system. Revision History Initial release. Document Cautions and Notes Two types of messages, identified below, appear in the text: CAUTION! Caution text indicates operations or steps that could cause personal injury, induce a safety problem in a managed device, destroy or corrupt information, or interrupt or stop services. NOTE: Note text contains information about special circumstances. General Safety Precautions CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. CAUTION! This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transceiver of any digital unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transceiver or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the adapter or connector. CAUTION! This system is an RF Transmitter and continuously emits RF energy. Maintain 3 foot (91.4 cm) minimum clearance from the antenna while the system is operating. Wherever possible, shut down the RAN before servicing the antenna. CAUTION! Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends. Fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a radius of less than 2 inches (5.1 cm). CAUTION! Exterior surfaces of the Remote may be hot. Use caution during servicing. Page 2 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Preface Standards Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Part 15 (Host unit), Part 22 (800 MHz Cellular), Part 24 (1900 MHz - PCS), Part 90 (800/900 - SMR), and Part 27 (700 MHz, 2100 MHz - AWS). IC: This equipment complies with the applicable sections of RSS-131. The term “IC:” before the radio certification number only signifies that Industry Canada Technical Specifications were met. The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. NOTE: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts ERP (Cellular and SMR), the antenna cannot exceed 1640 Watts EIRP (PCS), and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. NOTE: The U.S. Federal Communications Commission (FCC) has developed guidelines for evaluation of human exposure to RF emissions. The guidelines incorporate limits for Maximum Permissible Exposure (MPE) for power density of transmitter operating at frequencies between 300 kHz and 100 GHz. Limits have been set for portable, mobile, and fixed equipment. ADC products fall in the category of fixed equipment; products intended to be permanently secured and exposures are evaluated for distances greater than 20cm (7-7/8”). Portable devices fall into exposures of less than 20cm, where SAR evaluations are used. Antenna gain is restricted to 1.5 W ERP (2.49 W EIRP) in order to satisfy RF exposure compliance requirements. If higher than 1.5 W ERP, routine MPE evaluation is needed. The antennas should be installed to provide at least 20cm from all persons to satisfy MPE requirements of FCC Part 2, 2.1091. UL/CUL: This will be installed in a restricted access location. This equipment complies, per UL and CUL 50, Standard for Enclosures for Electrical Equipment. FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to all applicable standards of 21 CFR Part 1040. Caution: Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 3 © 2009 ADC Telecommunications, Inc. Introduction INTRODUCTION InterReach Spectrum is an addition to the InterReach family of Distributed Antenna Systems. It offers a flexible multi-operator/multi-protocol single platform system supporting up to 8 Radio Frequency (RF) bands. InterReach Spectrum has a Host Unit, an Expansion Unit (comprised of a DART Remote Module (DRU), IF Expansion Module (IFEU), and Power Supply), and Remote Amplifiers Units (RAUs). The Host, DRU and IFEU are intended for telecom closet indoor use. The RAU is intended to be installed above a false ceiling in an environmentally controlled office. The standard configuration is: • one Host Unit • up to sixteen Expansion Units • with each IFEU in the Expansion Unit supporting up to eight Main RAUs (one per IFEU FWD/REV F connector paired ports). Page 4 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Introduction Host Unit The Host Unit is installed into a 19-inch, rack-mounted chassis, that is 9-inches deep and can hold up to three Host Units. Each Host Unit can have up to eight hot swappable plug in cards. Host Unit components are as follows: • One SeRF board with eight SFP connectors, that go to the DART Remote Unit SFPs • Two Ethernet connections for Craft and Network access • One System board with an Alarm connector • One DCV Power board • Eight RF DART modules for Wireless Operator RF input from BTS or BDA • Replaceable Fans for cooling FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 5 © 2009 ADC Telecommunications, Inc. Introduction DART Remote Unit The DART Remote Unit (DRU) is installed into a 19-inch, rack-mounted chassis, that is 9-inches deep and can have up to eight hot swappable plug in cards. DRU components are as follows: • One SeRF board with eight SFP connectors, that go to the Host Unit SFPs • Two Ethernet connections for Craft and Network access • One System board with an Alarm connector • One DCV Power board • Eight RF DART boards with eight QMA connector IF inputs and eight QMA connector IF outputs to the IF Expansion Unit (IFEU) • Replaceable Fans for cooling Page 6 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Introduction IF Expansion Unit The IF Expansion Unit (IFEU) is installed into a 19-inch, rack-mounted chassis, that is 15-inches deep with three plug-in cards. IFEU components are as follows: • One Reverse Link Module with • – eight F connectors that go to the RAUs – eight QMA connectors that go to the DRU One DL PCBA with – eight F connectors that go to the RAUs – eight QMA connectors that go to the DRU • One Micro controller board • One DC/DC board • Backplane • Replaceable Fans for cooling FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 7 © 2009 ADC Telecommunications, Inc. Introduction Main Remote Access Unit The Main Remote Access Unit (MRAU) design allows for easier Band 1 and Band 2 Mix-and-Matching per country and/or market needs. MRAU components are as shown in the following figure. BTS 1 BTS 2 BTS 3 Band 1 and 2 Boards RAU pairing examples: 850/1900 700/700 MIMO 800/900 SMR 700 SISO/AWS 800/AWS To IF Expansion Unit (IFEU) Page 8 © 2009 ADC Telecommunications, Inc Connects up to three Secondary RAUs (SRAUs) To IF Expansion Unit (IFEU) FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Introduction Secondary Remote Access Unit The Secondary Remote Access Unit (SRAU) design allows for easier Band 1 and Band 2 Mix-and-Matching per country and/or market needs. SRAU components are as shown in the following figure. BTS 1 BTS 2 BTS 3 Band 1 and 2 Boards RAU pairing examples: 850/1900 700/700 MIMO 800/900 SMR 700 SISO/AWS 800/AWS Connects to Main RAU (MRAU) FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 9 © 2009 ADC Telecommunications, Inc. Introduction Omni Antenna The Omni Antenna (4214-M727) supports the following: • Port 1 – 698-806 MHz (700 LTE) – 1710-2170 MHz (AWS) • Port 2 – 806-941 MHz (Cellular/SMR) – 1850-1990 MHz (PCS) • Port 3 – 2500-2700 MHz (WiMAX) The Omni Antenna (see figure below) is a round radome with the following specifications: • 8.5-inch diameter • 1.65-inch height • 72-inch pigtails that are plenum-rated cables with N (male) connectors NOTE: Two antennas per RAU is required for MIMO performance. Page 10 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Installation INSTALLATION Follow the steps in the order in which they are presented. 1 Connect the Host single-mode fiber SFPs (1-4) to the DART Remote Unit SFPs (5-8): • HU SFP 1 to DRU SFP 5 • HU SFP 2 to DRU SFP 6 • HU SFP 3 to DRU SFP 7 • HU SFP 4 to DRU SFP 8 2 Connect the provided Vdc power cables to the +V and –V power-supply terminals. CAUTION! The Power Supply requires 2-20amp 120VAC outlets. FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 11 © 2009 ADC Telecommunications, Inc. Installation 3 Connect IF DART QMA cables to IFEU: a Connect QMA cable from all IF DART FWD OUT connectors to any IFEU FWD Module IF IN connector. b Connect QMA cable from all IF DART REV IN connector to any IFEU REV Module IF OUT connector. 4 Connect F connector CATV cable from IFEU FWD Module Port IF OUT to MRAU FWD IF IN F connector. Page 12 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Installation 5 Connect F connector CATV cable from IFEU REV Module Port IF IN to MRAU REV IF OUT F connector. 6 Connect MRAU and SRAU F FWD and REV connectors: a Connect F connector CATV jumper cable from MRAU FWD Secondary F connector to SRAU Secondary FWD F connector. b Connect F connector CATV jumper cable from MRAU REV Secondary F connector to SRAU Secondary REV F connector. FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 13 © 2009 ADC Telecommunications, Inc. Cascading CASCADING You add bands by inserting DART cards and CATV jumper between the Main and new Secondary RAUs, as shown below. 1 to 16 cascaded Expansion Units support up to 128 RAU locations. Page 14 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Specifications SPECIFICATIONS RF Specification Supported Frequency Blocks 2 per Remote Antenna Unit; 1-8 per Host Unit Bandwidth 1.5 to 75 MHz non-contiguous Frequency Band Supported 850 Cellular, 1900 PCS, 700 2100 AWS (Future Release) E-SMR 800/900 (Future Release) Propagation Delay System Delay <12 microseconds Delay Management Digital (Manual or Automatic) Noise Figure Noise Figure <12 dB Input IP3 >-10 dBm Optical Specifications Optical Budget 10 dB (Standard); 26 dB (Optional) Digital Transport Rate 3.072 Gbps Output Power Output Power per Band 26 dBm 850MHz Cell 26 dBm 1900MHz PCS 26 dBm 700MHz LTE 26 dBm 2100MHz AWS (future) Remote Access Unit Operating Temp -25°C to +50°C Storage Temperature -40°C to +70°C Humidity 10% to 90% non-condensing Dimensions 10.67" x 8.25" x 3.00" Weight 7.49 Pounds Host Unit and Dart Remote Unit Mounting 19- and 23-inch rack Dimensions (Rack mountable) 5.25" x 19.00" x 19.00" Weight <25 Pounds FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 15 © 2009 ADC Telecommunications, Inc. Specifications Host Unit and DART Remote Unit Power Requirements Power Source 21 to 60 VDC floating Battery Backup UPS IF Expansion Unit Mounting 19- and 23-inch rack Dimensions (Rack mountable) 5.25" x 17.11" x 11.93" Weight <19.5 Pounds IF Expansion Unit Power Requirements Power Source +51 to +57 VDC Battery Backup UPS Remote Access Unit Operating Temp -25°C to +50°C Storage Temperature -40°C to +70°C Humidity 10% to 90% non-condensing Dimensions 11.50" x 9.00" x 3.50" Weight 7.49 Pounds Remote Access Unit Power Requirements Power Source 54 VDC (from IFEU) Element Management Embedded EMS Yes SNMP Based Management Yes Page 16 © 2009 ADC Telecommunications, Inc FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Contacting ADC CONTACTING ADC PHONE : U.S.A. or CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Connectivity Extension: 73475 Wireless Extension: 73476 EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-917-3000 Technical Assistance: +1-952-917-3475 13944-Q WRITE: ADC Telecommunications (S’PORE) PTE, LTD; 100 Beach Road, #18-01, Shaw Towers. Singapore 189702. ADC Telecommunications, INC PO Box 1101, Minneapolis, MN 55440-1101, USA ADC European Customer Service, INC Belgicastraat 2, 1930 Zaventem, Belgium PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: connectivity.tac@adc.com wireless.tac@adc.com euro.tac@adc.com asiapacific.tac@adc.com REPRINTS: PDF copies of manuals are available for downloading at the following link: www.adc.com/manuals ADCP Number: 77-079 Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. FlexWave Prism Remote Unit Installation Guide ADCP-77-072 • Issue 2 • 11/2009 Page 17 © 2009 ADC Telecommunications, Inc. Website: www.adc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : barnesc Create Date : 2009:12:18 15:23:37Z Modify Date : 2009:12:18 15:32:12-08:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Spectrum.book Creator : barnesc Creator Tool : FrameMaker 7.1 Metadata Date : 2009:12:18 15:32:12-08:00 Producer : Acrobat Distiller 9.2.0 (Windows) Document ID : uuid:94969da6-ea06-4af4-81d1-0380d4cbf247 Instance ID : uuid:ba02633d-e816-4792-aeb2-775545463062 Page Mode : UseOutlines Page Count : 20EXIF Metadata provided by EXIF.tools