ADC Telecommunications S2797-011 Spectrum 700 Path 2/AWS Path 2 SRAU User Manual 77168p1
ADC Telecommunications Inc. Spectrum 700 Path 2/AWS Path 2 SRAU 77168p1
Manual
™ InterReach Spectrum Main and Secondary Remote Access Unit Installation Guide ADCP-77-168 Issue 2 07/2011 Main Remote Access Unit Secondary Remote Access Unit D-620731-0-20 Rev A Copyright © 2011 ADC Telecommunications, Inc. All Rights Reserved. Information contained in this document is company private to ADC Telecommunications, Inc. and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. Trademark Information ADC is a registered trademark and InterReach Spectrum is a trademark of ADC Telecommunications, Inc. No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. Other product names mentioned in this practice are for identification purposes only and may be trademarks or registered trademarks of their respective companies. Disclaimer of Liability Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Specific Disclaimer for High-Risk Activities This Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. ADC (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes. ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 917-1717 TABLE OF CONTENTS Preface.................................................................................................................... 1 InterReach Spectrum User Documentation .............................................................. 2 Document Cautions and Notes ............................................................................... 2 General Safety Precautions ................................................................................... 2 Standards Certification ......................................................................................... 3 Product Overview ..................................................................................................... 4 Main Remote Access Units..................................................................................... 5 MRAU Ports, Cable, and Connectors................................................................... 5 MRAU LEDs .................................................................................................... 6 Secondary Remote Access Units............................................................................. 7 SRAU Ports, Cable, and Connectors ................................................................... 7 SRAU LEDs .................................................................................................... 8 Install the RAUs and Antennas.................................................................................... 8 Mount the RAUs and Antennas............................................................................... 8 Connect the IFEU to the MRAU ............................................................................ 10 Connect the MRAU to SRAUs ............................................................................... 12 Configure the MRAUs and SRAUs ......................................................................... 13 Appendix A: Specifications ....................................................................................... 14 Spectrum System Specifications .......................................................................... 14 Remote Access Unit Specifications........................................................................ 15 Composite Power Out of RAU............................................................................... 15 Appendix B: 75-Ohm CATV Cable.............................................................................. 16 CATV Cable Requirements................................................................................... 16 Belden 1695A Coax Specifications ........................................................................ 17 Description .................................................................................................. 17 Overall Physical Characteristics ....................................................................... 17 Overall Nominal Electrical Characteristics ......................................................... 18 Belden 7732A Coax Specifications ........................................................................ 19 Description .................................................................................................. 19 Overall Physical Characteristics ....................................................................... 19 Overall Nominal Electrical Characteristics ......................................................... 19 Appendix C: Omni Antenna ...................................................................................... 21 Appendix D: Contacting ADC/TE Connectivity ............................................................. 22 PREFACE This manual provides installation instructions for ADC® InterReach Spectrum™ Remote Access Units. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 1 ©2011 ADC Telecommunications, Inc. Preface InterReach Spectrum User Documentation The InterReach Spectrum user documentation is intended for system administrators, engineers and installers responsible for planning, administering, configuring, and maintaining ADC InterReach Spectrum systems. Table 1 lists the manuals that correspond to this InterReach Spectrum release. Table 1. InterReach Spectrum User Documentation Title ADCP Number InterReach Spectrum Quick Start Guide ADCP-77-165 InterReach Spectrum Host Unit Installation Guide ADCP-77-166 InterReach Spectrum Expansion Module Group Installation Guide ADCP-77-167 InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 InterReach Spectrum™ Element Management System 7.2 User Manual ADCP-77-189 FlexWave Prism OADM Splice Box Installation Guide ADCP-77-151 Document Cautions and Notes Two types of messages, identified below, appear in the text: CAUTION! Caution text indicates operations or steps that could cause personal injury, induce a safety problem in a managed device, destroy or corrupt information, or interrupt or stop services. NOTE: Note text contains information about special circumstances. General Safety Precautions CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. CAUTION! This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transceiver of any digital unit or exposure to laser radiation may result. Use an optical power meter to verify active fibers. Immediately place a protective cap or hood over any radiating transceiver or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the adapter or connector. CAUTION! This system is a RF Transmitter and continuously emits RF energy. Maintain a minimum clearance of three feet (91.4 cm) from the antenna while the system is operating. Wherever possible, shut down the RAN before servicing the antenna. Page 2 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Preface Standards Certification FCC: This equipment complies with the applicable sections of Title 47 CFR, Part 22 (800 MHz Cellular), Part 24 (1900 MHz - PCS), Part 90 (800/900 - SMR), and Part 27 (700 MHz, 2100 MHz - AWS). IC: This equipment complies with the applicable sections of RSS-131 (800/900 – SMR), RSS-132 (800 - Cellular), and RSS-133 (1900 – PCS). The term “IC:” before the radio certification number only signifies that Industry Canada Technical Specifications were met. The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. NOTE: The U.S. Federal Communications Commission (FCC) has developed guidelines for evaluation of human exposure to RF emissions. The guidelines incorporate limits for Maximum Permissible Exposure (MPE) for power density of transmitter operating at frequencies between 300 kHz and 100 GHz. Limits have been set for portable, mobile, and fixed equipment. ADC products fall in the category of fixed equipment; products intended to be permanently secured and exposures are evaluated for distances greater than 20cm (7-7/8”). Portable devices fall into exposures of less than 20cm, where SAR evaluations are used. Antenna gain is restricted to 1.5 W ERP (2.49 W EIRP) in order to satisfy RF exposure compliance requirements. If higher than 1.5 W ERP, routine MPE evaluation is needed. The antennas should be installed to provide at least 20cm from all persons to satisfy MPE requirements of FCC Part 2, 2.1091. UL/CUL: This will be installed in a restricted access location. This equipment complies, per UL and CUL 50, Standard for Enclosures for Electrical Equipment. UL/CUL: This equipment complies with UL and CUL 60950-1 Standard for Safety for Information Technology Equipment, including Electrical Business Equipment. UL: This equipment is UL Plenum rated under UL 2043. CAUTION! Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 3 © 2011 ADC Telecommunications, Inc. Product Overview PRODUCT OVERVIEW InterReach Spectrum supports up to eight frequency bands in a single system. Each antenna location supports those bands in modular, group pairings. Each location includes a Main Remote Access Unit (MRAU), which can power up to three additional Secondary Remote Access Units (SRAUs). An MRAU supports two frequency bands, and each SRAU can support up to two frequency bands, for a total of up to eight frequency bands. MRAUs and SRAUs are grouped logically, based on common service provider groupings and include, as an example: • 850/1900 • 700/700 MIMO • 800/900 SMR • 1900/AWS. To add more frequency bands, you connect an SRAU to the existing MRAU. Figure 1 illustrates how RF and IF signals are sent between Spectrum units and modules. Secondary Remote Access Unit RF RF DART Remote Unit Host IF IF Expansion Unit Key to Signal Path IF RF IF Omni Antenna Power Supply Reverse (REV) Expansion Module Group Forward (FWD) Main Remote Access Unit Figure 1. REV and FWD Signals for the RAU NOTE: This book refers to the Omni Antenna (4214-M727), which is the antenna that ADC recommends. Other antennas may be used. For further information on the Omni Antenna, see “Appendix C: Omni Antenna” on page 21. Page 4 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Product Overview Main Remote Access Units The Main Remote Access Unit (MRAU) receives FWD IF signals from an IF Expansion Unit (IFEU), which is part of the Spectrum Expansion Module Group, using 75 CATV cable. The MRAU converts the IF signals to RF and sends them to a passive RF antenna using 50 coaxial cable. The MRAU also receives configuration information and power from and sends its status information to the IFEU. The MRAU receives REV RF signals from a passive RF antenna using 50 coaxial cable. It converts the signals to IF and sends them to the IFEU using 75 CATV cable. MRAU Ports, Cable, and Connectors REV IF OUT REV SECONDARY PORTS Ref # Component LINK STATUS FWD SECONDARY PORTS Device FWD IF IN Function RF SubMiniature version A (SMA) cable (1) Connects two RF bands together when there is only one N-type connector on the RAU. 50 RF SMA-to-SMA cable For cases when there is an N-type connector for each RF band (700MIMO or PCS/AWS), there will not be an SMA cable. Antenna port 50 N-type connector Connects to an antenna. FWD IF IN connector F connector port Connects to the IFEU FWD Module IF OUT connector via CATV cable. FWD SECONDARY PORTS (1 - 3) F connector ports Connect to a SRAU SECONDARY FWD connector via CATV cable. REV SECONDARY PORTS (1 - 3) F connector ports Connect to a SRAU SECONDARY REV connector via CATV cable. REV IF OUT connector Connects to the IFEU REV Module IF IN connector via CATV cable. F connector port (1) The AWS/PCS MRAUs does NOT have an RF SMA cable, and has two Antenna ports. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 5 © 2011 ADC Telecommunications, Inc. Product Overview MRAU LEDs REV IF OUT REV SECONDARY PORTS Ref # LED LINK LED Color STATUS FWD SECONDARY PORTS FWD IF IN Description • Green FWD SECONDARY PORT (1 - 3) LINK STATUS REV SECONDARY PORT (1 - 3) FWD IF IN Page 6 © 2011 ADC Telecommunications, Inc • Downstream unit correctly connected; unit has no alarms or a Minor alarm is active. • Blinking Green • SRAU or band is set out-of-service. • Yellow • FWD cable connected to SRAU, no REV cable connected. • Blinking Yellow • FWD and REV cables are not connected to the same port number (incorrectly paired). • Red • Major alarm in downstream unit, fault lockout, or SRAU disconnected. • Off • No SRAU previously connected. • Green • MRAU receiving communications from the IFEU. • Red • MRAU has not received communications from the IFEU for more than 90 seconds. • Off • During initial power up, MRAU is powering up and waiting for IFEU communications. • Green • Unit has no alarms or a Minor alarm is active. • Blinking Green • Unit or band is set out-of-service. • Red • Major alarm detected. • Green • Downstream unit correctly connected, unit has no alarms or minor alarm • Blinking Green • SRAU or band is set out-of-service. • Blinking Yellow • FWD and REV cables are not connected to the same port number (incorrectly paired). • Red • Major alarm in downstream unit, fault lockout, or SRAU disconnected. • Off • No SRAU previously connected. • Green • MRAU is powered on correctly. • Yellow or • There is an IFEU FWD connection, but there is no IFEU REV Blinking Yellow connection or the IFEU REV connection is paired incorrectly. • Off • Cable is not connected to the IFEU FWD port. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Product Overview Secondary Remote Access Units A Secondary Remote Access Unit (SRAU) receives FWD IF signals from the MRAU, using 75 CATV cable. The SRAU converts the IF signals to RF and sends them to a passive RF antenna using 50 coaxial cable. The SRAU, through the MRAU, also receives configuration information and power from and sends its status information to the IFEU. The SRAU receives REV RF signals from a passive RF antenna using 50 coaxial cable. It converts the signals to IF and sends them to the MRAU using 75 CATV cable. SRAU Ports, Cable, and Connectors SECONDARY SECONDARY REV FWD LINK STATUS Ref Component Device Function SECONDARY REV connector F connector port Connects to one of the MRAU REV SECONDARY ports (1 - 3) via CATV cable. RF SMA cable Connects two RF bands together when there is only one N-type connector on the RAU. 50 RF SMA-to-SMA cable For cases when there is an N-type connector for each RF band (700MIMO or PCS/AWS), there will not be an SMA cable. Antenna port SECONDARY FWD connector F connector port (1) 50 N-type connector Connects to an antenna. Connects to one of the MRAU FWD SECONDARY ports (1 - 3) via CATV cable. (1) The 700 MIMO SRAUs does NOT have an RF SMA cable, and has two Antenna ports. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 7 © 2011 ADC Telecommunications, Inc. Install the RAUs and Antennas SRAU LEDs SECONDARY SECONDARY REV Ref # LED LED Color STATUS Description • Green • Red LINK • FWD LINK • • • • SECONDARY FWD • STATUS • • SRAU receiving communications from the IFEU. • SRAU has not received communications from the IFEU for more than 90 seconds. Off • During initial power up, SRAU is powering up and waiting for IFEU communications. Green • Unit has no alarms or a Minor alarm is active. Blinking Green • Unit or band is set out-of-service. Red • Major alarm detected. Green • MRAU is powered on correctly. Yellow or • There is an MRAU FWD connection, but there is no MRAU REV connection Blinking Yellow or the MRAU REV connection is paired incorrectly. Off • Cable is not connected to the MRAU FWD port. INSTALL THE RAUS AND ANTENNAS Follow the steps in the order provided to install the RAUs and antennas. Mount the RAUs and Antennas CAUTION! Install RAUs in indoor locations only. Do not connect an antenna installed in an outdoor location to a RAU, unless it is in an approved AOC weatherproof NEMA4 housing. CAUTION! Attach all RAUs securely to a stationary object (that is, a wall, pole, or ceiling brackets). To mount a RAU securely to a wall, ceiling bracket, or pole, use #6 diameter fasteners in the four slotted mounting holes. CAUTION! Do the following to maintain proper ventilation: • Keep at least 76 mm (3-inch) clearance around the RAU. • Do not stack RAUs on top of each other. • Always mount the RAU with the solid face (containing the mounting holes) against the mounting surface. Page 8 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Install the RAUs and Antennas NOTE: RAUs are suitable for use in environmental air space in accordance with Section 300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1. NOTE: You can place the RAU, without its fastening hardware, on a flat surface, such as a shelf, desk, cabinet, or any other horizontal surface that allows stable placement, with the mounting base facing down to the mounting surface. CAUTION! If installing the RAU on a flat surface, the surface must be able to hold a minimum 7-pound load securely. 1 Mount all MRAU and SRAUs in the locations marked on the floor plans. 2 Install the passive antennas according to the manufacturer’s installation instructions. NOTE: It is common practice to install passive antennas below the ceiling. If you install a passive antenna above the ceiling, when estimating the antenna coverage area, account for additional loss due to the ceiling material. 3 Connect a passive multi-band antenna to the N connector on each RAU using coaxial cable with the least amount of loss possible. (See “Appendix C: Omni Antenna” on page 21 for information on the Omni Antenna ports.) CAUTION! Firmly hand-tighten the N connector. DO NOT over-tighten the connector. MRAU REV IF OUT False Ceiling REV SECONDARY PORTS LINK STATUS FWD SECONDARY PORTS Coaxial cable SRAU N1 FWD IF IN SECONDARY SECONDARY FWD REV LINK Omni Antenna InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 N1 STATUS Coaxial cable Page 9 © 2011 ADC Telecommunications, Inc. Install the RAUs and Antennas Connect the IFEU to the MRAU NOTE: The IFEU should be powered up before starting this procedure; see the InterReach Spectrum Expansion Module Group Installation Guide (ADCP-77-167). 4 Follow these rules for the CATV cables when connecting the IFEU to the MRAU: • The FWD and REV cables should be close to the same length. • The FWD and REV cables should be the same cable type (both RG6 or both RG11). • A pair of CATV cables connects each MRAU to the IFEU. The IFEU REV Module IF IN port and the IFEU FWD Module IF OUT port must match. For example, if IFEU REV Module IF IN Port 3 is used, use IFEU FWD Module IF OUT Port 3. • Refer to “Appendix B: 75-Ohm CATV Cable” on page 16 for information on maximum RG-6 or RG-11 CATV cable lengths. 5 Test the cable termination for each CATV cable before installing it. 6 Connect F connector CATV cables on the IFEU and MRAU, in the order given below. If the LEDs do not perform as described in this procedure, refer to “MRAU LEDs” on page 6. a Connect a CATV cable from one of the IFEU FWD Module IF OUT connectors (1 - 8) to the MRAU FWD IF IN connector. b Confirm that the MRAU FWD IF IN LED is yellow, which indicates a correct physical connection. Connect a CATV cable from the IFEU REV Module IF IN connector (1 - 8) to the MRAU REV IF OUT connector, making sure that you pair the port used to the same port number selected in Step 6a. If the connection is correct, the MRAU powers up and the MRAU FWD IF IN LED turns green. Page 10 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Install the RAUs and Antennas IFEU Step 6a To an antenna MRAU REV IF OUT REV SECONDARY PORTS LINK Step 6c InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 STATUS FWD SECONDARY PORTS FWD IF IN Step 6b Page 11 © 2011 ADC Telecommunications, Inc. Install the RAUs and Antennas Connect the MRAU to SRAUs CAUTION! To prevent interference, do not install an 850/1900 MRAU antenna near an 800/900 SRAU. The 850 MHz band must be 20 feet away from the 800/1900 SRAU’s passive antenna. 7 Use one of the following 6’ and 20’ CATV RG6 jumpers, available for purchase from ADC, to connect an MRAU to SRAUs. ADC Part Number Description Note 300469-0 6’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two cables required per SRAU. 300469-1 20’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two cables required per SRAU. 8 Test the cable termination for each CATV cable before installing it. 9 Connect F connector CATV cables from the MRAU to an SRAU, in the order given below. If the LEDs do not perform as described in this procedure, refer to “SRAU LEDs” on page 8. a Connect a CATV cable from an MRAU FWD SECONDARY PORT (1, 2, or 3) F connector to the SRAU SECONDARY FWD F connector. b Confirm that the SRAU SECONDARY FWD LED is yellow, which indicates a correct physical connection. Connect a CATV cable from an MRAU REV SECONDARY PORT (1, 2, or 3) F connector to the SRAU SECONDARY REV F connector, matching the same port number selected in Step 9a. That is, if in Step 9a you connected an F connector to the MRAU FWD SECONDARY PORT 1, the paired CATV cable must connect to the MRAU REV SECONDARY PORT 1. If the connection is correct, the SRAU powers up and the SRAU SECONDARY FWD LED turns green. MRAU To an antenna REV IF OUT REV SECONDARY PORTS LINK STATUS FWD SECONDARY PORTS FWD IF IN To an IFEU FWD Module IF OUT connector (1 - 8) To an IFEU REV Module IF IN connector (1 - 8) To an antenna SRAU SECONDARY SECONDARY REV FWD LINK Page 12 © 2011 ADC Telecommunications, Inc STATUS InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Install the RAUs and Antennas 10 Repeat Step 9 to install up to two more SRAUs, as per system design. MRAU To an antenna REV IF OUT REV SECONDARY PORTS LINK STATUS FWD SECONDARY PORTS FWD IF IN To an IFEU REV Module IF IN connector (1 - 8) To an IFEU FWD Module IF OUT connector (1 - 8) To an antenna SECONDARY SECONDARY REV SRAU1 SECONDARY FWD LINK SECONDARY REV FWD STATUS LINK To an antenna To an antenna SECONDARY STATUS SRAU3 SECONDARY REV FWD LINK STATUS SRAU2 Configure the MRAUs and SRAUs Refer to the ADC InterReach Spectrum™ Element Management System 7.0 User Manual (ADCP-77-163) for information on how to configure the MRAUs and SRAUs. InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 13 © 2011 ADC Telecommunications, Inc. Appendix A: Specifications APPENDIX A: SPECIFICATIONS Spectrum System Specifications RF Specification Supported Frequency Blocks 2 per Remote Antenna Unit; 1-8 per Host Unit Bandwidth 1.5 to 75 MHz non-contiguous Frequency Band Supported 850 Cellular; 800 iDEN; 900 iDEN; 1900 PCS; 2100 AWS; 700 Upper C Lower ABC Propagation Delay System Delay <12 microseconds Delay Management Digital (Manual or Automatic) Noise Figure Noise Figure For 1 Host, 1 DRU, 8 RAUs: < 17 dB For 1 Host, 4 DRUs, 32 RAUs: < 23 dB Input IP3 >-10 dBm Optical Specifications Optical Budget 10 dB (Standard); 26 dB (Optional) Digital Transport Rate 3.072 Gbps Nominal Passband Gain Average gain with 190m of CATV at 25° C (77° F) (dB) 700 - 900 MHz 1900 - 2100 MHz Typical Typical TX RX TX RX 40 30 40 30 Output Power Output P1dB Power per Band Page 14 © 2011 ADC Telecommunications, Inc 26 dBm 850MHz Cell 26 dBm 1900MHz PCS 26 dBm 700MHz Upper C Lower ABC 26 dBm 2100MHz AWS InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Appendix A: Specifications Remote Access Unit Specifications Operating Temp -25°C to +50°C Storage Temperature -40°C to +70°C Humidity 10% to 90% non-condensing Dimensions 11.50" x 9.00" x 3.50" Weight 7.49 Pounds Power Source 54VDC (from IFEU) Composite Power Out of RAU RF Frequency TX 850 Cell 869-894 RX 824-849 800 SMR 851-869 806-824 900 SMR 935-940 896-901 1900 PCS 1930-1995 1850-1915 Number of RF Carriers 16 26 23 20 18 17.5 GSM 23 20.5 18 17 17 EDGE 16 16 16 16 15 14 12.5 CDMA WCDMA 17.5 17 16 15.5 iDEN 26 22.5 19.5 17.5 APCO 25 C4FM 17.5 17 16 15.5 iDEN 26 22.5 19.5 17.5 APCO 25 C4FM 26 23 20 18 17.5 GSM 23 20.5 18 17 17 EDGE 16 16 16 16 15 14 12.5 WCDMA CDMA 2100 AWS 2110-2155 1710-1755 15 14 12.5 WCDMA 700 Upper C 746-756 776-786 15 14 12.5 LTE 700 Lower ABC 728-746 698-716 15 14 12.5 LTE InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 15 © 2011 ADC Telecommunications, Inc. Appendix B: 75-Ohm CATV Cable APPENDIX B: 75-OHM CATV CABLE The 75-Ohm CATV Cable: • connects the IFEU to MRAU(s) and the MRAU(s) to the SRAU(s) • transmits (FWD) multiband and receives (REV) IF signals • delivers DC electrical power to the RAUs. The Spectrum IFEU DC voltage output is 54VDC nominal. If the IFEU reaches its current limit, a current-limiting circuit protects it. • carries configuration and status information • uses 75 type-F connectors with captive centerpins. CATV Cable Requirements Belden CATV cable or equivalent is required (see Figure 2). • For the RG-6 cable, use a Belden 1695A Coax. • For the RG-11 cable, use a Belden 7732A Coax. NOTE: ADC requires solid copper center conductor CATV cable for proper DC voltage to the RAU and maximum distances. RG-6 RG-11 Belden 1695A Coax Belden 7732A Coax Figure 2. Belden 1695A and 7732A Coax Cables Page 16 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Appendix B: 75-Ohm CATV Cable • Use RG-6 or RG-11 CATV cable between the IFEU and MRAU, the typical lengths of which are listed below. Cable Type Minimum Length Maximum Length Meters Feet Meters Feet RG-6 140 459 RG-11 200 656 • Use only RG-6 CATV cable between the MRAU and SRAU, the lengths of which are listed below. RG-6 Cable Meters Feet Typical 6.56 800/900 iDEN to 850 CELL 19.68 800 AWS to 850 CELL 19.68 Belden 1695A Coax Specifications Description RG-6/U type, 18 AWG solid 0.040-inch bare copper conductor, plenum, foam FEP insulation, Duofoil® + tinned copper braid shield (95% coverage), Flamarrest® jacket. Overall Physical Characteristics Conductor One Coax 18 AWG Solid stranding Bare Copper (BC) conductor material 0.040-inch diameter Insulation Teflon® Foam Fluorinated Ethylene Propylene (FFEP) 0.170-inch diameter Outer Shield Layer 1 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100% coverage Outer Shield Layer 2 Braid Tinned Copper (TC) 95% coverage Outer Jacket Flamarrest® Low Smoke Polyvinyl Chloride (LS PVC) Overall Cabling 0.234-inch overall nominal diameter InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 17 © 2011 ADC Telecommunications, Inc. Appendix B: 75-Ohm CATV Cable Overall Nominal Electrical Characteristics Characteristic Impedance 75.000 Inductance 0.103 H/ft. Capacitance Conductor to Shield 16.100 (pF/ft.) Velocity of Propagation 82 (%) Delay 1.240 (ns/ft.) Conductor DC Resistance 6.400 @ 20°C (/1000 ft.) Outer Shield DC Resistance 2.800 @ 20°C (/1000 ft.) Attenuation Freq. (MHz) Attenuation (dB/100 ft.) Page 18 © 2011 ADC Telecommunications, Inc 1.000 0.240 3.580 0.450 5.000 0.550 7.000 0.650 10.000 0.750 67.500 1.740 71.500 1.780 88.500 1.940 100.000 2.100 135.000 2.400 143.000 2.500 180.000 2.800 270.000 3.400 360.000 4.000 540.000 5.200 720.000 6.100 750.000 6.200 1000.000 7.300 1500.000 9.200 2000.000 10.900 2250.000 11.600 3000.000 13.700 InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Appendix B: 75-Ohm CATV Cable Belden 7732A Coax Specifications Description RG-11/U type, 14 AWG solid 0.064-inch bare copper conductor, plenum, foam FEP insulation, Duofoil® + tinned copper braid shield (95% coverage), fluorocopolymer jacket. Overall Physical Characteristics Conductor One Coax 18 AWG Solid stranding Bare Copper (BC) conductor material 0.064-inch diameter Insulation Teflon® Foam Fluorinated Ethylene Propylene (FFEP) 0.274-inch diameter Outer Shield Layer 1 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100% coverage Outer Shield Layer 2 Braid Tinned Copper (TC) 95% coverage Outer Jacket Fluorocopolymer (PVDF) Overall Cabling 0.348-inch overall nominal diameter Overall Nominal Electrical Characteristics Characteristic Impedance 75.000 Inductance 0.091 H/ft. Capacitance Conductor to Shield 16.300 (pF/ft.) Velocity of Propagation 83 (%) Delay 1.220 (ns/ft.) Conductor DC Resistance 2.500 @ 20°C (/1000 ft.) Outer Shield DC Resistance 1.600 @ 20°C (/1000 ft.) InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 19 © 2011 ADC Telecommunications, Inc. Appendix B: 75-Ohm CATV Cable Attenuation Freq. (MHz) Attenuation (dB/100 ft.) Page 20 © 2011 ADC Telecommunications, Inc 1.000 0.150 3.580 0.260 5.000 0.300 7.000 0.340 10.000 0.400 67.500 1.200 71.500 1.240 88.500 1.400 100.000 1.500 135.000 1.780 143.000 1.840 180.000 2.090 270.000 2.600 360.000 3.100 540.000 3.890 720.000 4.570 750.000 4.680 1000.000 5.500 1500.000 6.910 2000.000 8.130 2250.000 9.200 3000.000 10.200 InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Appendix C: Omni Antenna APPENDIX C: OMNI ANTENNA The Omni Antenna (4214-M727), shown in Figure 3, is a round radome with the following specifications: • 8.5-inch diameter • 1.65-inch height • 72-inch pigtails that are plenum-rated cables with N (male) connectors Figure 3. Omni Antenna NOTE: Two antennas per RAU is required for MIMO performance. The Omni Antenna supports the following: • Port 1 – 698-806 MHz (700 Upper C Lower ABC) – 1710-2170 MHz (AWS) • Port 2 – 806-941 MHz (Cellular/SMR) – 1850-1990 MHz (PCS) • Port 3 – 2500-2700 MHz (WiMAX) InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Page 21 © 2011 ADC Telecommunications, Inc. Appendix D: Contacting ADC/TE Connectivity APPENDIX D: CONTACTING ADC/TE CONNECTIVITY NOTE: ADC is now TE Connectivity. PHONE U.S.A. or CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-530-9960 Connectivity Extension: 73475 Wireless Extension: 73476 EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-917-3000 Technical Assistance: +1-952-917-3475 EMAIL Connectivity Products United States: Connectivity.Tac@te.com Europe: Euro.Tac@te.com Asia/Pacific: AsiaPacific.Tac@te.com All Wireless Products WirelessSupport@te.com ONLINE ACCESS Customer Portal http://www.adc.com/Americas/en_US/1268116693520 Online Customer Support Request https://nssales.adc.com/ftr/ftrhome1.asp Page 22 © 2011 ADC Telecommunications, Inc InterReach Spectrum Remote Access Unit Installation Guide ADCP-77-168 • Issue 2 • 07/2011 Website: www.adc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : TE106558 Create Date : 2011:07:08 12:52:36Z Modify Date : 2011:07:08 13:59:42-07:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.4.5 (Windows) Creator Tool : FrameMaker 7.1 Metadata Date : 2011:07:08 13:59:42-07:00 Format : application/pdf Title : 77168p1.book Creator : TE106558 Document ID : uuid:99f78d98-db5d-4c57-8357-69eb6ee246ea Instance ID : uuid:aa6b8f10-eede-4e75-89e8-7e09ede15ed2 Page Mode : UseOutlines Page Count : 26EXIF Metadata provided by EXIF.tools