AIPHONE GTDBVN GT Apartment Intercom System User Manual ENG GT DMB MKB 17 05 29 indd
AIPHONE CO.,LTD. GT Apartment Intercom System ENG GT DMB MKB 17 05 29 indd
AIPHONE >
Users Manual
GT SYSTEM Entrance station (modular type) Entrance station (all-in-one type) Guard station OPERATION MANUAL Entrance station (modular type) Guard station Entrance station (all-in-one type) ZOOM WIDE ADJUST Q R X Y Thank you for selecting Aiphone for your communication needs. Please read this manual carefully before installation, and keep this in a safe place for future reference. Please note that images and illustrations depicted in this manual may differ from the actual product. PRECAUTIONS Prohibited Do not dismantle unit Keep unit away from water Be sure to follow the instruction Notice WARNING (Negligence could result in death or serious injury.) • We will under no conditions be liable for any damages or losses resulting from this product's contents or specifications. • We will under no conditions be liable for damage occurring due to the inability to communicate due to malfunctions, problems, or operational errors in this product. • The unit is inoperative during power failure. • This system is not intended for life support or crime prevention. It is just a supplementary means of conveying information. Aiphone will under no conditions be liable for loss of life or property which occurs while the system is being operated. • In areas where broadcasting station antennas are close by, this system may be affected by radio frequency interference. • Please note the LCD panel, though manufactured with very high precision techniques, inevitably will have a very small portion of its image elements always lit or not lit at all. This is not considered a unit malfunction. • The unit may get slightly warm, but this is not a malfunction. • During communication, if you speak before the other person has finished talking, your voice may not come through clearly. Conversation will proceed smoothly if you speak when the other person has finished talking. • The entrance station is intended to be mounted on a wall only. It cannot be used on a desktop. • Available functions and services are limited according to the specifications of the installed system. • If you speak in a fixed tone, the noise-cut function may judge it to be a noise and cut the transmission, but this is not a malfunction. • Using a mobile phone or professional-use radio equipment such as walkietalkie close to the system may cause a malfunction. • Warm-color lighting shining on the camera may change the tint of the image on the screen. • The outline of video images displayed may differ from that of the actual person(s) or background, but this is not a malfunction. • When the unit’s screen is illuminated with strong light, the image looks white or silhouetted. But this is not a unit trouble. • When outside temperature lowers sharply after rainfall, etc., the inside of the camera may fog up slightly, causing a blurry images, but this is not a malfunction. Normal operation will be restored when moisture evaporates. • When using a fluorescent light that shines around the camera, the screen colors may variously change (color rolling), but it is not a malfunction. • If the entrance station freezes during winter time, the picture may become difficult to see or the buttons of the entrance station may not operate. 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. Do not put any metal and flammable material into the unit through the openings. Fire, electric shock, or unit trouble could result. 3. Keep the unit away from water or any other liquid. Fire or electric shock could result. 4. During an electrical storm, do not touch the unit. Electric shock could result. 5. If there is any smoke, unusual odor, or abnormal sound, or if you drop or damage the unit, turn off the system power breaker immediately. Fire or electric shock could result. 6. Do not use power supply with a voltage other than specified. Fire or electric shock could result 7. Do not use the unit in/under following locations/conditions. If not observed, it may result in noises or malfunctions. • Where use of the unit is prohibited, such as in a hospital • Near an electric medical equipment (e.g. operating rooms, ICU, or CCU) • Near automatic control equipment such as auto doors or fire-alarm boxes • In the area within 15cm from a cardiac pacemaker CAUTION (Negligence could result in injury to people or damage to property.) 1. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could result. 2. Do not apply high pressure on the screen. If fractured, injury could result. 3. If the LCD is punctured, do not touch the liquid crystal inside. Inflammation could result. If contact should occur, flush or rinse area with water thoroughly and consult your doctor. 4. Be sure to perform a call test with the handset on the hook. If you operate the hook switch with the handset on your ear, a sudden call etc. may arrive causing damage to your ear. 5. Do not place your ear near the speaker during use. An unexpected loud sound could cause hearing damage. 6. When cleaning the wall with a high-pressure water sprayer, be careful not to spray on the entrance station. If not observed, it may result in fire or electric shock. General Precautions 1. Keep the unit more than 1 m (3.3') away from radio or TV set. 2. Keep more than 20 cm (7-7/8") away from other radio equipment, for example floor heating controller, wireless router or cordless telephone, etc. It may cause unwanted noise and video distortion. 3. Talk within 30 cm (12'') from this unit. If you are too far away, it may be difficult to hear audio. 4. When installing and using this unit, protect subject's privacy, portrait rights, etc. on your own responsibility. 5. As to other manufacturer's devices (such as sensor, detectors, door releases) used with this system, comply with the Specifications and Warranty conditions that the manufacturers or venders present. 6. Avoid using this unit in places under direct sunlight. If it is unavoidable, block out light during use. 7. When putting a hearing aid into T-mode and approaching the unit, the intercom system may be affected by radio frequency interference etc., depending on the installation environment. 8. Please receive and retain all configuration data from the supplier. If you lose the configuration data, there are cases where maintenance and after-sales service calls may incur additional setup fees. 10. The area to be monitored by the sensor should be free of obstacles such as ornamental plants. -2- Table of Contents 7 OTHER OPERATIONS ................................................ 45 7-1 Checking for missed calls and calling back ............. 45 7-2 Receiving an emergency call ................................... 46 PRECAUTIONS........................................................... 2 READ THIS BEFORE USING THE STATIONS 8 SETTING........................................................................ 48 8-1 Adjusting display brightness and volumes ............... 48 8-2 Switching to reception mode ................................... 50 8-3 Switching to program mode ..................................... 51 1 SYSTEM CONFIGURATION ........................................ 4 2 NOTES ABOUT USING THIS MANUAL .................... 5 9 UPDATING RESIDENT INFORMATION .................. 52 ENTRANCE STATION 1 PART NAMES AND FUNCTIONS ............................... 6 1-1 Entrance station (modular type) ................................. 6 1-2 Entrance station (all-in-one type)............................... 7 1-3 Indicators.................................................................... 8 FOR PROPER USE OF THIS STATION 1 TECHNICAL PRECAUTIONS .................................... 53 2 SPECIFICATIONS ........................................................ 54 2 OPERATIONS ................................................................. 9 2-1 Calling a resident/tenant or guard station .................. 9 Calling with the call switch module....................... 9 Calling with the name scrolling module ................ 9 Calling with the 10 key module ........................... 10 Calling with the all-in-one type entrance station (GT-DMB-LVN/GT-DMB-N).............................. 12 2-2 Door release ............................................................. 16 2-3 Other ........................................................................ 16 3 SOFTWARE LICENSE ................................................ 56 4 REGULATIONS ............................................................ 57 5 WARRANTY .................................................................. 58 GUARD STATION 1 PART NAMES AND FUNCTIONS ............................. 17 1-1 Operation panel ........................................................ 17 1-2 Indicators.................................................................. 18 1-3 LCD (display) .......................................................... 19 1-4 Button operations ..................................................... 20 2 RECEIVING A CALL ................................................... 22 2-1 Receiving a call ........................................................ 22 3 CALLING (from a tenant building) ......................... 23 3-1 How to search for a unit to call (from a tenant building) ........................................... 23 3-2 Calling a unit (residential/tenant station) or guard station ........................................................ 24 3-3 Calling an entrance station ....................................... 29 4 CALLING (from a main building) ............................ 31 4-1 How to select a unit to call (from a main building) ............................................. 31 4-2 Calling a room (residential/tenant station) or guard station ........................................................ 32 4-3 Calling an entrance station ....................................... 37 5 OPERATIONS DURING COMMUNICATION .......... 39 5-1 Transferring a call .................................................... 39 5-2 Door release ............................................................. 39 5-3 Operating an optional device ................................... 40 5-4 Viewing and adjusting video at an entrance station ....................................................................... 41 6 MONITORING ............................................................... 43 -3- READ THIS BEFORE USING THE STATIONS SYSTEM CONFIGURATION The GT system consists of up to 8 main buildings and 24 tenant buildings. Main building: A control section that functions as a main entrance, guard station, security center, administration office, etc. A main building includes no residential/tenant stations. You can call up all of the residential/tenant stations and guard stations from an entrance station or guard station in the same system (site). * A station that is not programmed cannot be called. * Modular type entrance stations cannot be installed in a main building. Only all-in-one type can be used. Tenant building: A section of collective housing. A tenant building includes residential/tenant stations, entrance stations and guard stations. You can call up all of the residential/tenant stations and guard stations from an entrance station in the same tenant building. However, you cannot call stations in another tenant building. Example : A system (site) consisting of 1 main and 3 tenant buildings Residential/tenant stations GT-2C-L/GT-2C (GT-2H-L/GT-2H) GT-1C7-L/ GT-1C7 GT-1M3-L/ GT-1M3 GT-1A GT-1D Tenant building Tenant building Tenant building Entrance station (modular type) Entrance station (all-in-one type) GT-DMB-LVN/ GT-DMB-N Main building (administration office) B C H I K L U V Q R E F NO X Y Entrance station (all-in-one type only) GT-DMB-LVN/ GT-DMB-N Guard station GT-MKB-N -4- Guard station GT-MKB-N READ THIS BEFORE USING THE STATIONS Coverage of calling, communication and monitoring The following table shows the coverage of calling, communication, and monitoring from a tenant building and a main building. NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured. Incoming call Other tenant buildings Same tenant building Outgoing call Entrance Guard st. st. Tenant Entrance st. Calling/ communication building Guard st. Calling/ communication Monitoring Entrance st. Calling/ Main communication building Guard st. Calling/ communication Monitoring ✓ : Possible Residential/ Entrance Guard tenant st. st. st. Same main building Other main buildings Residential/ Entrance Guard Entrance Guard tenant st. st. st. st. st. ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ — : Impossible About the term "building" and "section": The term "section" is used on the setting screens of entrance stations and guard stations instead of "building". "Section" and "building" have the same meaning in this manual. Setting screen of guard station e.g. CALLING METHOD Standby screen of guard station e.g. BUILDING # 01 NAME / # SEARCH SECT LIST+UNIT # UNIT NUMBER SECT # + UNIT # UNIT # NOTES ABOUT USING THIS MANUAL This manual describes how to use the entrance stations and guard stations. The use of them differs depending on the building/section (main or tenant) where they belong. This manual uses the following icons to separate descriptions for the main and tenant buildings. Icon Meaning Main building/section Tenant building/section -5- ENTRANCE STATION PART NAMES AND FUNCTIONS 1-1 Entrance station (modular type) Camera module GT-VB Name scrolling module GT-NSB Display Back search button (or move the cursor to the left) Forward search button (or move the cursor to the right) Camera Call button (or set and move forward) Illuminator LED Cancel button (or back) Q R 10 key module GT-10K GT-DB-V (VIGIK and NFC capable) GT-DB-VN 10-key (0 to 9, Audio module X Y , #) (VIGIK capable) GT-DB Microphone IN USE LED (orange) Call indicator (orange) Talk indicator (orange) Door release indicator (green) NFC reader Speaker Call switch module GT-SW Call button Directory card [Combination examples] Audio only, Direct select type (8 stations) Audio/video, Direct select type (8 stations) GT-VB + GT-VP GT-DB(-V, -VN) + GT-DBP GT-SW + GF-4P GF-BP Audio only, 10 key type GT-DB (-V, -VN) + GT-DBP X Y Q R Q R GT-DB (-V,-VN) + GT-DBP GT-VB + GT-NSB + GT-VP GT-NSP-L GT-10K + GF-10KP Audio/video, Direct select type Audio/video, 10 key type GT-VB + GT-VP GT-NSB + GT-NSP-L GT-SW + GF-4P GT-DB(-V, -VN) + GT-DBP X Y -6- GT-10K + GF-10KP GT-DB (-V, -VN) + GT-DBP GT-NSB + GT-NSP-L GT-SW + GF-4P ENTRANCE STATION 1-2 Entrance station (all-in-one type) All-in-one entrance station GT-DMB-N (NFC capable) Microphone Camera Illuminator LED Talk indicator (orange) Display Call indicator (orange) IN USE LED (orange) Door release indicator (green) NFC reader Speaker Back search button (or move cursor to the left) 10-key (0 to 9, , #) Forward search button (or move cursor to the right) Cancel button (or back) Call button (or set and move forward) Sensor (If the sensor detects an object, the display will be illuminated.) All-in-one entrance station GT-DMB-LVN (VIGIK and NFC capable, Hearing aid compatible) Each part and indicator are the same as GT-DMB-N except as shown below (VIGIK). VIGIK (available in France) -7- ENTRANCE STATION 1-3 Indicators Entrance station (modular type) Entrance station (all-in-one type) 2 3 4 1 2 3 Q R X Y Indication patterns Indicator 1 IN USE LED 2 Call Status (orange) 3 Talk indicator 4 Door indicator 5 Display release indicator Standby Off Off Off Off WELCOME System in use Lit Off Off Off IN Call Off Lit Off Off (*1) Communication Off Off Lit Off (*2) Releasing a door Off Off Monitoring Off Off Communication is on hold Lit Off (*1) Off (*2) USE CALLING SMITH IN COMMUNICATION Lit DOOR Off Off WELCOME Off Off ON (*1): Lit when door release is activated during call. (*2): Lit when door release is activated during communication. (*3): The display differs depending on the settings. -8- (*3) OPEN HOLD (*3) ENTRANCE STATION OPERATIONS : Main building/section Calling a resident/tenant or guard station Calling with the call switch module ■ Searching for a unit by scrolling the list In standby mode, press and target unit # and resident name. to display the The call indicator will light up and you will hear a call tone. * Audio guidance will be heard depending on the settings. Press the call button for the unit to be called. 101 SMITH When the call is answered Communication starts and the talk indicator lights up. * Audio guidance will be heard depending on the settings. * Depending on the settings, only the resident name may be displayed. * The list is displayed in order of either unit # or resident name. When the door is released Press The door release indicator lights up. * Audio guidance will be heard depending on the settings. Calling with the name scrolling module 2-1 : Tenant building/section The call indicator will light up and you will hear a call tone. * Audio guidance will be heard depending on the settings. When the call is answered Communication starts and the talk indicator lights up. * Audio guidance will be heard depending on the settings. When the door is released The door release indicator lights up. * Audio guidance will be heard depending on the settings. -9- ENTRANCE STATION ■ Searching for a unit by entering resident name Q R 10-key Calling with the 10 key module X Y ■ Searching for a unit by entering the unit # In standby mode, enter the numbers using [0] to [9] on the 10-key to display the target unit # and resident name. In standby mode, press on the 10-key. When "ENTER A LETTER" is displayed, enter a letter using the 10-key to display the target unit # and resident name. The number and resident name for the unit whose initial corresponds to the entered letter will be displayed. (e.g.) Enter "S". 101 SMITH Q R X Y * Pressing or searches for the next unit # and resident name. * Depending on the settings, only the resident name may be displayed. * When the unit # is set to not be displayed, a letter can be entered without pressing * If there is no relevant resident name, "NO ENTRY" is displayed. 101 SMITH When the target unit # and resident name is displayed, press . NO ENTRY: The call indicator will light up and you will hear a call tone. * Audio guidance will be heard depending on the settings. NOTES: Pressing or for approximately 2 seconds will display resident names in succession. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to display in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. • * If there is no relevant unit #, "NO ENTRY" is displayed. NO ENTRY * When the residential/tenant station that has been called is in use, the IN USE LED lights up to indicate that the residential/ tenant station cannot be called. (In an expanded system, there may be a case that a residential/ tenant station cannot be called even if the IN USE LED is off.) When the call is answered Communication starts and the talk indicator lights up. * Audio guidance will be heard depending on the settings. When the door is released The door release indicator lights up. * Audio guidance will be heard depending on the settings. - 10 - ENTRANCE STATION When the target unit # or resident name is displayed, press . Q R X Y The call indicator will light up and you will hear a call tone. * Audio guidance will be heard depending on the settings. When the call is answered Communication starts and the talk indicator lights up. * Audio guidance will be heard depending on the settings. When the door is released The door release indicator lights up. * Audio guidance will be heard depending on the settings. - 11 - ENTRANCE STATION Calling with the all-in-one type entrance station GT-DMB-LVN/GT-DMB-N The following diagram shows the screen transitions starting from the standby screen. One of the standby screens shown below is preset to this station. Find the standby screen of this station from A to E below and confirm the transition from it, and refer to the designated page for the calling operation. NOTE: If "NO ENTRY" is displayed on the screen, press Standby screen Display OFF (black) * Depending on the setting, the screen turns on automatically when you get closer to this station. 10-key/ / Turned on automatically Greeting message A QUICK LIST Picture INFORMATION 101 102 103 201 WELCOME SMITH AIPHONE DENTIST LAINE NUMBER ALPHA 10-key/ 10-key/ To the next page B or C ( C is available in a tenant building/section only.) Call operation screen B NAME / # SEARCH D SECT LIST + C UNIT NUMBER E SECT# + UNIT# UNIT# HOW TO CALL HOW TO CALL 1. ENTER UNIT # 2. CALL 2. CALL NUMBER HOW TO CALL HOW TO CALL 1. SELECT UNIT 1. BUILDING LIST 2. SELECT 3. ENTER UNIT # 4. CALL 1. ENTER BLDG. # 2. SELECT 3. ENTER UNIT # 4. CALL ALPHA 10-key 10-key 10-key ENTER UNIT # UNIT LIST UNIT # 101 SMITH BUILDING LIST ENTER BUILDING # 01 CENTRAL TOWER BUILDING # SELECT ENTER ALPHA CALL CANCEL To the next page B CALL ALPHA CANCEL To the next page C CANCEL To the next page D - 12 - CANCEL To the next page E ENTRANCE STATION Confirming the target unit in the quick list Entering unit # NOTE: Entering unit # can only be performed on this screen. Unit # and resident names frequently called are preset to be displayed in the quick list. Entering resident name is not possible. HOW TO CALL * Up to 4 units can be displayed. 1. ENTER UNIT # INFORMATION Unit # 101 102 103 201 2. CALL SMITH AIPHONE DENTIST LAINE When the target unit number is numerals only ALPHA NUMBER Resident name In standby mode, press and to display the target unit, or 10-key to change the standby screen. In standby mode, enter numbers using [0] to [9] on the 10-key to display the target unit #. * The 10-key can be used even after pressing or ENTER UNIT # UNIT # ALPHA CALL or CANCEL * Depending on the system, only the resident name may be displayed. The "UNIT LIST" screen B or "ENTER UNIT #" screen C is displayed. * If you have entered a wrong number, press to return to standby mode. Follow the operating procedure of either B or C depending on the displayed screen. When the target unit # is displayed, press The target unit is called. * Refer to "When the target unit is successfully called" at the end of 2-1 for details. * C is available in a tenant building/section only. When the target unit number is alphanumeric Searching for a unit in the unit list In standby mode, press on the 10-key. * The 10-key can be used even after pressing HOW TO CALL 1. SELECT UNIT or ENTER UNIT # UNIT # 2. CALL NUMBER NUMBER ALPHA ALPHA CALL CANCEL In standby mode, press and or 10-key to display the target unit # and resident name. UNIT LIST 101 SMITH Enter letters using the 10-key to display the target unit #. * Refer to the next page for how to enter letters. CALL CANCEL or The 10-key can be used to enter unit #, or by pressing the 10-key can be used to enter letters (resident name). , then When the target unit # is displayed, press * Depending on the settings, only the resident name may be displayed. * The list is displayed in order of either unit # or resident name. * If you have entered a wrong number, press to return to standby mode. When the target unit is displayed, press The target unit is called. * Refer to "When the target unit is successfully called" at the end of 2-1 for details. The target unit is called. * Refer to "When the target unit is successfully called" at the end of 2-1 for details. - 13 - ENTRANCE STATION How to enter letters (e.g.) Entering "CATHY" 1. To enter "C", press 2. Press Searching for a building in the building list and entering unit # HOW TO CALL three times. 1.BUILDING LIST 2.SELECT 3.ENTER UNIT # 4.CALL (*1) once. 3. To enter "A", press once. 4. To enter "T", press once. 5. To enter "H", press twice. 6. To enter "Y", press three times. In standby mode, press and to display the target building number and name. BUILDING LIST (*1): This step is needed for entering different letters with the same 01 CENTRAL TOWER key sequentially. SELECT CANCEL To enter a special character , : Press once. - : Press twice. . : Press three times. / : Press four times. When the target building is displayed, press Enter numbers or letters using the 10-key to display the target unit #. five times. Space : Press * For entering numbers or letters, follow steps 1 and 2 of Æ : Press six times. Ø : Press seven times. C - Å : Press eight times. or "When the target unit number is numerals only" "When the target unit number is alphanumeric". ENTER UNIT # * If you have entered a wrong letter, press 01 CENTRAL TOWER UNIT # 101 to return to standby mode. CALL ALPHA When the target unit # is displayed, press The target unit is called. * Refer to "When the target unit is successfully called" at the end of 2-1 for details. - 14 - ENTRANCE STATION Entering a building # and unit # When the target unit is successfully called HOW TO CALL The call indicator will light up and you will hear a call tone. * Audio guidance will be heard depending on the settings. 1.ENTER BLDG# 2.SELECT 3.ENTER UNIT # 4.CALL When the call is answered In standby mode, enter numbers or letters using the 10-key to display the target building. Communication starts and the talk indicator lights up. * Audio guidance will be heard depending on the settings. * For entering numbers or letters, follow steps 1 and 2 of C or "When the target unit number is numerals only" "When the target unit number is alphanumeric". When the door is released The door release indicator lights up. * Audio guidance will be heard depending on the settings. ENTER BUILDING # BUILDING # 01 ALPHA ENTER NOTES: CANCEL If "DENIED" is displayed or returns to standby mode, the entered unit #/resident name is not registered. • Enter the target unit # exactly. Otherwise, "DENIED" is displayed or returns to standby mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to be displayed in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. • When the target building number is displayed, press Enter numbers or letters using the 10-key to display the target unit #. * For entering numbers or letters, follow steps 1 and 2 of C or "When the target unit number is numerals only" "When the target unit number is alphanumeric". ENTER UNIT # BUILDING # 01 UNIT # 101 CALL ALPHA When the target unit # is displayed, press The target unit is called. * Refer to "When the target unit is successfully called" at the end of 2-1 for details. - 15 - ENTRANCE STATION 2-2 Door release ■ Door release by using the access code ■ Door release by an NFC-compliant IC card, etc. * The access code is preset by the system installer or administrator. A card incorporated with an NFC tag can be used to release a door. To use, the ID of the NFC tag must be registered as a door release code. In standby mode, enter [#] and then the access code (4 to 6 digits) using [0] to [9] on the 10-key. [Modular type] [All-in-one-type] Pass an NFC-compliant IC card over the NFC reader. [Modular type] Q R NFC reader [All-in-one-type] X Y (e.g.) When the access code is "4567", enter "#", "4", "5", "6", "7". * Put the card within 10 mm of the NFC reader. Otherwise, the code may not be read correctly. The door is released. The door is released. • The door release indicator lights up. • Audio guidance will be heard depending on the settings. • The door release indicator lights up. • Audio guidance will be heard depending * If there is no relevant number, "DENIED" is displayed. * Door release is enabled even while the IN USE LED is lit. on the settings. * Door release is enabled even while the IN USE LED is lit. NOTE: Do not overlap IC cards when passing them over the NFC reader. The code may not be read correctly. 2-3 Other * Calling from an entrance station is disabled while the IN USE LED is lit. Wait until the IN USE LED turns off. NOTE: For a multi building system with lift control, if you unlock from a room and terminate call at the same time, the entrance station may not unlock properly. - 16 - GUARD STATION PART NAMES AND FUNCTIONS 1-1 Operation panel Color LCD monitor (Display) Handset Status LED (orange) Speaker Indicates the current status of this station by lighting up or flashing on/off in orange (while initializing the system, being called, communicating, etc.). Multi-function buttons • • • • LIGHT VIDEO CALL LIST SETTING NFC reader Reset button 10-key (0 to 9, , #) ZOOM WIDE Option button ADJUST Microphone OFF button ADJUST button ZOOM/WIDE button MONITOR button (up) (left) (right) (down) TALK button Door release ( - 17 - ) button GUARD STATION 1-2 Indicators ZOOM WIDE ADJUST Indication patterns Status Indicator 6 Status LED (orange) Standby Off Standby (Call tone volume: off) Long interval flashing Standby (Reception mode: on) Slow flashing This station is in use by another station (this station is inoperable) Off Being called by an entrance station Fast flashing (0.5 sec.) (0.5 sec.) (0.5 sec.) Being called by a door station (2.5 sec.) (0.5 sec.) Normal flashing (1 sec.) Being called by a door bell (5.5 sec.) (1 sec.) Fast flashing (0.5 sec.) Monitoring an entrance station Lit Communicating with an entrance station Lit Calling another guard station or residential/tenant station (including in reception mode) Fast flashing Sounding an emergency alarm Fast flashing (0.5 sec.) (0.5 sec.) (1 sec.) (0.5 sec.) (0.5 sec.) A new list of missed calls from residential/tenant stations has arrived Slow flashing Error indication Off (An error message is displayed.) Communication is on hold Off (0.5 sec.) - 18 - (2.5 sec.) GUARD STATION 1-3 LCD (display) The following are samples of typical screens and icons. In standby mode * When nothing is displayed (black) on the screen, the screen below can be displayed by pressing any key other than , 0-9, or lifting the handset. Status display icons NAME SEARCH ZOOM WIDE The following icons are displayed here depending on the status of this station. Icon EMERGENCY The status when the icon appears Appears when this station is in reception mode. NAME SEARCH MISSED CALLS Appears while searching for a unit. Appears while the number or letter entry screen is displayed. Appears while receiving a call. Appears when a record of missed calls is displayed. Appears while in communication. Appears while transferring. Appears while this station is in communication with a residential/tenant station after transferring a call from an entrance station to the residential/tenant station. NAME SEARCH screen The screen for searching for a unit by its name. Appears when a record of emergency calls is displayed. Appears while monitoring. List page number When the list of units or setting items consists of two or more pages, the current page number is shown here. Appears while a wide video at the entrance or a video at the door station is displayed. Appears while a zoom video at the entrance station is displayed. Appears when the setting screen is displayed. Information display Displays the unit # or resident name of selected station, operation method, etc. NAME SEARCH 101 102 103 201 202 1 /8 SMITH AIPHONE DENTIST LAINE MENIN List of units The list of units you searched for is shown here by their unit # and resident names. Nothing appears in the list when no corresponding unit is detected. NOTE: The above display example may differ from the actual one. - 19 - GUARD STATION 1-4 Button operations ■ Multi-function buttons and icons The functions to be performed by the multi-function buttons are displayed by icons just above the buttons. Multi-function buttons Functions shown by icons here can be performed by pressing the buttons just below the icons. The icons vary depending on the status of this station. When the same icon as the icon above a button is displayed, the button performs the function shown by the button name. Displays the setting screen. Turns on the light at an entrance station. (e.g.) Pressing adjusts receive volume ( ). Starts communication with the preset entrance station, or displays video from a surveillance camera. Displays the search item list. (e.g.) restores the previous screen ( Pressing ). Icons and their functions Icons and their functions for each multi-function button are as follows. Icon Function Icon Determines the choice. Function Changes the 10-key to the letter entry mode. Turns the entrance light on (when light is installed in common area). Adjusts brightness. Changes the 10-key to the number entry mode. Turns off the emergency alarm. Adjusts receive volume. Displays the search item list. Calls the selected unit. Transfers a call from entrance station to residential/tenant station. Adjusts call tone volume. Restores the previous screen. Displays the setting screen. Cancels the choice. Turns off overlay. Calls the preset entrance station directly. Deletes the selected item. - 20 - GUARD STATION ■ How to enter numbers and letters by using the 10-key (0 to 9, , #) Use the 10-key in the number or letter entry mode. The number and letter entry modes can be switched by pressing ). Number entry mode UNIT # Entered numbers are displayed. ZOOM WIDE ADJUST Letter entry mode UNIT # How to enter letters To enter a special character (e.g.) Entering "CATHY" 1. To enter "C", press ZOOM 2. Press WIDE once. three times. (*1) , : Press once. - : Press twice. . : Press three times. four times. 3. To enter "A", press once. / : Press 4. To enter "T", press once. Space : Press 5. To enter "H", press twice. 6. To enter "Y", press three times. (*1): This step is needed for entering different letters with the same five times. Æ : Press six times. Ø : Press seven times. Å : Press eight times. key sequentially. * If you have entered a wrong letter, press to standby mode. - 21 - to return GUARD STATION RECEIVING A CALL : Main building/section : Tenant building/section Receiving a call 2-1 When receiving a call, the call tone sounds and the number and name of the caller (station) are displayed in the screen. ZOOM WIDE ADJUST Caller The caller can be confirmed on the display. A call from a residential/ tenant station or another guard station The unit # and station name A call from an entrance station with a camera A call from an entrance station without a camera The number and entrance name The number and entrance name 101 DR.DOUIEB,PATRI 1011 PARKING GATE A call from a door station 10 ENTRANCE1 DOOR STATION The video at the entrance The video at the door station NOTE: When receiving a call from a door bell, nothing is displayed on the screen and answering is not possible. Answering a call To answer a call * While communicating with the caller, unlock the door or use the other features by pressing the following buttons. Press Adjusting display brightness (→ 8-1 ) or lift handset. Adjusting call tone volume (→ 8-1 ) 1011 PARKING GATE ZOOM WIDE Adjusting receive volume (→ 8-1 ) ADJUST or Operating an optional device (→ 5-3 ) ZOOM WIDE Begin communication with the caller. ADJUST Adjusting screen view (→ 5-4 ) Door release (→ 5-2 ) * Lift handset at any time for privacy. Pan/tilt (→ 5-4 ) Zoom/wide (→ 5-4 ) To end communication Press or hang up handset. Communication ends automatically after 3 minutes. * Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. - 22 - GUARD STATION CALLING (from a tenant building) How to search for a unit to call (from a tenant building) 3-1 The following methods are available in standby mode to search for a unit (residential/tenant station) or guard station to call. Searching by number Searching by name Using the search item list * When nothing is displayed (black) on the screen, press any key other than mode. , 0-9, or lift handset to enter standby * An entrance station can be searched for by using method C only. Standby mode NAME SEARCH ZOOM WIDE EMERGENCY NAME SEARCH MISSED CALLS ZOOM WIDE Searching by number (→ 3-2 ) NUMBER SEARCH Searching by name (→ 3-2 ) ADJUST Using the search item list (→ 3-2 ) UNIT BY NUMBER 101 SMITH 101 102 103 104 105 1 / 4 SMITH AIPHONE DENTIST YOKOI YABE 101 102 103 201 202 1 / 1 SMITH AIPHONE DENTIST LAINE MENIN UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE • Searching by number (UNIT BY NUMBER) (→ 3-2 ) • Searching by name (UNIT BY NAME) (→ 3-2 ) • Searching a guard station from the guard station list (GUARD STATION) (→ 3-2 ) • Searching an entrance station from the entrance station list (ENTRANCE) (→ 3-3 ) - 23 - GUARD STATION Coverage of calling from a guard station in a tenant building NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured. Same tenant building Outgoing call Entrance st. Guard st. Tenant Guard st. building 3-2 ✓ Residential/ tenant st. ✓ ✓ Calling a unit (residential/tenant station) or guard station Searching for a unit by number In standby mode, enter numbers using [0] to [9] on the 10-key to display the target unit # and resident name. Unit # whose initial number matches the entered number are displayed in the list. * The list is displayed in order of unit #. * This station is not displayed. Select the target unit by pressing ZOOM WIDE ZOOM or WIDE ZOOM WIDE * Press ADJUST ZOOM ZOOM or WIDE WIDE to turn the page of the list. ), or lift handset. When the call is answered Communication starts and " or hang • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to be displayed in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. 1 / 4 SMITH AIPHONE DENTIST YOKOI YABE 101 102 103 104 105 To end communication, press up handset. NOTES: Press Entrance st. Guard st. Guard st. — : Impossible NUMBER SEARCH Entrance st. ✓ Entered number(s) Main building Calling/ communication ✓ ✓ : Possible Residential/ tenant st. Incoming call Other tenant buildings " is displayed. - 24 - GUARD STATION Searching for a unit by name ZOOM In standby mode, press ZOOM or WIDE WIDE The search screen is displayed. ZOOM Select the target unit by pressing WIDE ZOOM or WIDE Selected unit # and resident name 101 SMITH ZOOM ADJUS WIDE 101 102 103 201 202 1 / 1 SMITH AIPHONE DENTIST LAINE MENIN Unit # and resident names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either unit # or name. * This station is not displayed. Press ), or lift handset. When the call is answered Communication starts and " " is displayed. To end communication, press up handset. or hang NOTES: • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • Stations can be set to be displayed in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. - 25 - GUARD STATION Searching for a unit by using the search item list Press ). UNIT BY NUMBER The search item list is displayed. UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE Searching for a unit by unit # ZOOM Select "UNIT BY NUMBER" by pressing WIDE or ZOOM WIDE Press ), or lift handset. When the call is answered Communication starts and " " is displayed. UNIT BY NUMBER ADJUS WIDE Press UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE ZOOM ) or ZOOM WIDE The "NUMBER SEARCH" screen is displayed. Enter numbers using [0] to [9] on the 10-key to display the target unit # and resident name. Entered unit # NUMBER SEARCH 101 102 103 104 105 1 / 4 SMITH AIPHONE DENTIST YOKOI YABE Unit # whose initial number matches the entered number are displayed in the list. * The list is displayed in order of unit #. * This station is not displayed. Select the target unit by pressing ZOOM WIDE ZOOM or * Press WIDE ZOOM ZOOM WIDE or WIDE to turn the page of the list. - 26 - To end communication, press up handset. or hang GUARD STATION Searching for a unit by resident name ZOOM Select "UNIT BY NAME" by pressing Press ), or lift handset. ZOOM or WIDE WIDE When the call is answered UNIT BY NAME UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE ZOOM ADJUS WIDE Press Communication starts and " ) or ZOOM WIDE The "NAME SEARCH" screen is displayed. Enter an alphabetical character using [0] to [9] on the 10-key to display the target resident name. Entered character NAME SEARCH 102 1 /1 AIPHONE The unit # and resident names whose initial letter matches the entered letter are displayed in the list. (e.g.) When "A" is entered, 301A, 1003ABC, ABC, etc. are displayed in the list. * The arranging method differs depending on the setting. * The list is displayed in order of name. * This station is not displayed. ZOOM Select the target unit by pressing WIDE ZOOM or WIDE ZOOM ADJUS WIDE * Press ZOOM ZOOM WIDE or WIDE to turn the page of the list. - 27 - " is displayed. To end communication, press up handset. or hang GUARD STATION Searching for a guard station from the guard station list Searching for an entrance station (→ 3-3 ) ZOOM Select "GUARD STATION" by pressing WIDE or ZOOM WIDE NOTES: GUARD STATION UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE ZOOM ADJUS WIDE Press • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to be displayed in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. ) or ZOOM WIDE The guard station list is displayed. ZOOM Select the target guard station by pressing WIDE ZOOM or WIDE 001 GUARD1 ZOOM ADJUS WIDE 001 002 003 1 / 1 GUARD1 GUARD2 GUARD3 Guard station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either station number or name. * This station is not displayed. Press ), or lift handset. When the call is answered Communication starts and " " is displayed. To end communication, press up handset. or hang - 28 - GUARD STATION Calling an entrance station 3-3 Direct calling an entrance station Press ). (only when The search item list is displayed. is displayed in standby mode) When is displayed, press ). ZOOM The preset entrance station is called, and then communication is enabled. ADJUST WIDE ZOOM Select "ENTRANCE" by pressing WIDE WIDE ENTRANCE UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE ZOOM ADJUS WIDE Press ) or ZOOM WIDE The entrance station list is displayed. Select the target entrance station by pressing ZOOM WIDE ZOOM or WIDE Selected entrance station number and name 0001 ENTRANCE1 ZOOM ADJUST WIDE 0001 0002 0003 0004 0005 1 / 1 ENTRANCE1 ENTRANCE2 ENTRANCE3 ENTRANCE4 ENTRANCE5 Entrance station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either station number or name. Press ), Communication starts and " or lift handset. " is displayed. To end communication, press up handset. Talk hands-free or lift the handset. ZOOM or or hang NOTE: Communication will end automatically after approximately 3 minutes. - 29 - To end communication, press up handset. or hang GUARD STATION Transferring video image taken by an entrance station camera or surveillance camera to a residential/tenant station (only when is displayed in standby mode) Press ). Select a residential/tenant station by one of the following methods A - C . A Press ZOOM ) and then WIDE ZOOM or WIDE to select the target residential/tenant station. B 1 Enter a number by using the 10-key to display the list of residential/tenant stations that include the number. 2 Press ZOOM ZOOM or WIDE WIDE to select the target residential/tenant station. 3 Press C 1 Press ) or ZOOM WIDE and enter a letter by using the 10-key to display the list of residential/ tenant stations that include the letter. 2 Press ZOOM WIDE ZOOM or WIDE to select the target residential/tenant station. 3 Press ) or ZOOM WIDE Press When the resident/tenant station answers and ). accepts the visitor, press handset. or hang up * Step 2 differs depending on the settings. - 30 - GUARD STATION CALLING (from a main building) How to select a unit to call (from a main building) 4-1 The following methods are available in standby mode to select a room (residential/tenant station) or guard station to call. Searching by number Searching for a unit in the list Entering unit # Searching for a building in the list + entering unit # Entering a building # + unit # * Any of 1 to 4 are available by default. Using the search item list * When nothing is displayed (black) on the screen, press any key other than mode. , 0-9, or lift handset to enter standby * To return to the standby screen, press * An entrance station can be searched for by using the method C only. Standby mode UNIT # ZOOM WIDE EMERGENCY UNIT # MISSED CALLS NAME SEARCH ZOOM WIDE EMERGENCY NAME SEARCH MISSED CALLS BUILDING ZOOM WIDE EMERGENCY BUILDING MISSED CALLS ZOOM ADJUST WIDE Searching by number (→ 4-2 ) NUMBER SEARCH B-1 B-2 101 102 103 104 105 1 / 4 SMITH AIPHONE DENTIST YOKOI YABE B-3 B-4 Searching for a unit in the list (→ 4-2 ) Entering unit # (→ 4-2 ) Searching for a building in the list + unit # (→ 4-2 ) Entering a building # + unit # (→ 4-2 ) Using the search item list (→ 4-2 ) BUILDING BUILDING GUARD STATION ENTRANCE • Searching for a building in the list + entering unit # or Entering a building # + unit # (→ 4-2 ) • Searching a guard station from the guard station list (GUARD STATION) (→ 4-2 ) • Searching an entrance station from the - 31 - entrance station list (ENTRANCE) (→ 4-3 ) GUARD STATION Coverage of calling from a guard station in a main building NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured. Tenant building Outgoing call Entrance st. Main Guard st. building Guard st. Residential/ tenant st. Incoming call Same main building Other main buildings Entrance st. Guard st. Entrance st. Guard st. Calling/ communication ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ : Possible 4-2 Calling a room (residential/tenant station) or guard station A Searching for a unit by number In standby mode, enter numbers using [0] to [9] on the 10-key to display the target unit # and name. Press ), or lift handset. When the call is answered Communication starts and " " is displayed. Entered number(s) NUMBER SEARCH 101 102 103 104 105 1 / 4 SMITH AIPHONE DENTIST YOKOI YABE • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to display in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. * The list is displayed in order of unit #. * This station is not displayed. ZOOM Select the target unit by pressing WIDE ZOOM or WIDE ZOOM WIDE * Press WIDE ADJUST ZOOM ZOOM or WIDE or hang NOTES: Unit # whose initial number matches the entered number are displayed in the list. To end communication, press up handset. to turn the page of the list. - 32 - GUARD STATION B-1 Searching for a unit in the list ZOOM In standby mode, press B-2 Entering unit # ZOOM or WIDE WIDE The unit list is displayed. ZOOM In standby mode, press ZOOM or WIDE WIDE "UNIT #" screen is displayed. ZOOM Select the target unit, by pressing WIDE ZOOM or WIDE [When the target unit number is numerals only] Enter the unit # using [0] to [9] on the 10-key. Selected unit # and name [When the target unit number is alphanumeric] 101 SMITH ZOOM ADJUS WIDE 101 102 103 201 202 1 Press ( ). 2 Enter the resident name using [0] to [9] on 1 / 1 SMITH AIPHONE DENTIST LAINE MENIN the 10-key. * How to enter letters (→P. 21). Entered number is displayed. UNIT # Unit # and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press 10 ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either unit # or name. * This station is not displayed. Press ), or lift handset. Press ), When the call is answered When the call is answered Communication starts and " " is displayed. * Audio guidance will be heard depending on the settings. Communication starts and " To end communication, press up handset. or hang or lift handset. " is displayed. To end communication, press up handset. or hang NOTES: • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to display in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. NOTE: Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. - 33 - GUARD STATION B-3 Searching for a building in the list + entering unit # ZOOM In standby mode, press B-4 Entering a building # + unit # or WIDE WIDE ZOOM Select the target building by pressing WIDE or ZOOM WIDE 01 CENTRAL TOWER WIDE 01 02 03 04 05 [When the target building number is numerals only] Enter the building number using [0] to [9] on the 10-key. 1 Press ). 2 Enter the building name using [0] to [9] on 1 / 1 CENTRAL TOWER EAST TOWER WEST TOWER NORTH TOWER SOUTH TOWER ADJUS WIDE [When the target building number is alphanumeric] Selected building number and name ZOOM ZOOM or WIDE "BUILDING #" screen is displayed. The building list is displayed. ZOOM In standby mode, press ZOOM the 10-key. * How to enter letters (→P. 21). Entered number is displayed. BUILDING # Building numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either building number or name. Press ) or ZOOM WIDE ) or ZOOM WIDE "UNIT #" is displayed. "UNIT #" is displayed. Press [When the target unit number is numerals only] Enter the unit # using [0] to [9] on the 10-key. [When the target unit number is numerals only] Enter the unit # using [0] to [9] on the 10-key. [When the target unit number is alphanumeric] [When the target unit number is alphanumeric] 1 Press ). 2 Enter the resident name using [0] to [9] on 1 Press ). 2 Enter the resident name using [0] to [9] on the 10-key. the 10-key. * How to enter letters (→P. 21). * How to enter letters (→P. 21). Selected building is displayed. BUILDING # 01 CENTRAL TOWER 01 UNIT # UNIT # Entered number is displayed. Entered number is displayed. Press ), or lift handset. ), or lift handset. When the call is answered When the call is answered Communication starts and " Press Communication starts and " " is displayed. To end communication, press up handset. or hang - 34 - " is displayed. To end communication, press up handset. or hang GUARD STATION Entering a building # + unit # C Searching for a unit by using the search item list Searching for a building in the list + entering unit # Press Press ). The search item list is displayed. ZOOM Select "BUILDING" by pressing ). WIDE ZOOM or WIDE BUILDING The search item list is displayed. BUILDING GUARD STATION ENTRANCE ZOOM ZOOM Select "BUILDING" by pressing WIDE ZOOM or WIDE WIDE ADJUS BUILDING BUILDING GUARD STATION ENTRANCE ZOOM WIDE ADJUS Press ) or ZOOM WIDE "BUILDING #" screen is displayed. Press ) or ZOOM WIDE NOTES: The building list is displayed. Follow steps 2 to 6 of B-4 . • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to display in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. Follow steps 2 to 6 of B-3 . - 35 - GUARD STATION Searching for a guard station from the guard station list ZOOM Select the target guard station by pressing WIDE ZOOM or Press WIDE ). The search item list is displayed. 01 CENTRAL TOWER 001 GUARD1 1 / 1 001 GUARD1 002 GUARD2 003 GUARD3 ZOOM Select "GUARD STATION" by pressing WIDE or ZOOM ADJUS WIDE ZOOM WIDE GUARD STATION BUILDING GUARD STATION ENTRANCE ZOOM ADJUS WIDE Guard station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press Press ZOOM ) or or WIDE WIDE to turn the page of the list. * The list is displayed in order of either station number or name. * This station is not displayed. WIDE ZOOM ZOOM The building list is displayed. ZOOM Select the target building by pressing WIDE or ), or lift handset. When the call is answered ZOOM WIDE Press Communication starts and " " is displayed. Selected building number and name 01 CENTRAL TOWER ZOOM 1 / 1 CENTRAL TOWER EAST TOWER WEST TOWER NORTH TOWER SOUTH TOWER ADJUS WIDE 01 02 03 04 05 • Communication will end automatically after approximately 3 minutes. Communication with a residential/tenant station in hands-free mode ends automatically after 1 minute in hands-free mode. • If both unit # 111 and 1111 exist, the resident name for unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time. • Stations can be set to display in order by unit #. (The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001. ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either building number or name. Press ) or ZOOM WIDE or hang NOTES: Building numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press To end communication, press up handset. The guard station list is displayed. - 36 - GUARD STATION Calling an entrance station 4-3 Press ). Select the target entrance station. Selected entrance station number and name The search item list is displayed. 0001 ENTRANCE1 ZOOM WIDE ADJUS WIDE ZOOM 0001 0002 0003 0004 0005 ADJUST ZOOM Select "ENTRANCE" by pressing WIDE ZOOM or WIDE Entrance station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. ENTRANCE BUILDING GUARD STATION ENTRANCE ZOOM ADJUS WIDE 1 / 1 ENTRANCE1 ENTRANCE2 ENTRANCE3 ENTRANCE4 ENTRANCE5 * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either station number or name. Press ZOOM ) or WIDE ), or lift handset. Communication starts and " " is displayed. * Audio guidance will be heard depending on the settings. ZOOM Select the target building by pressing WIDE or ZOOM WIDE When the call is answered The building list is displayed. Press To end communication, press up handset. or hang Selected building number and name 01 CENTRAL TOWER NOTE: Communication will end automatically after approximately 3 minutes. ZOOM 1 / 1 CENTRAL TOWER EAST TOWER WEST TOWER NORTH TOWER SOUTH TOWER ADJUS WIDE 01 02 03 04 05 Building numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either building number or name. Press ) or ZOOM WIDE The entrance station list is displayed. - 37 - GUARD STATION Direct calling an entrance station (only when Transferring video image taken by an entrance station camera or surveillance camera to a residential/tenant station is displayed in standby mode) When (only when is displayed, press mode) ). The preset entrance station is called, and then communication is enabled. Talk hands-free or lift the handset. To end communication, press up handset. is displayed in standby Press ). Select a residential/tenant station by one of the following methods A - C . or hang A Press ZOOM ) and then WIDE ZOOM or WIDE to select the target residential/tenant station. B 1 Enter a number by using the 10-key to display the list of residential/tenant stations that include the number. 2 Press ZOOM ZOOM or WIDE WIDE to select the target residential/tenant station. 3 Press C 1 Press ) or ZOOM WIDE and enter a letter by using the 10-key to display the list of residential/ tenant stations that include the letter. 2 Press ZOOM WIDE ZOOM or WIDE to select the target residential/tenant station. 3 Press ) or ZOOM WIDE Press When the resident/tenant station answers and ). accepts the visitor, press handset. * Step 2 differs depending on the settings. - 38 - or hang up GUARD STATION OPERATIONS DURING COMMUNICATION 5-1 Transferring a call 5-2 A call from an entrance station can be transferred to a residential/ tenant station via a guard station Door release While receiving a call or communicating with an entrance station, press After the guard station is called from an entrance ZOOM WIDE station, press the call. ADJUST or lift handset to answer The number and name of calling entrance station Door release is activated at the entrance station. 1011 PARKING GATE ZOOM WIDE * Audio guidance will be heard depending on the settings. Press ( ) or enter the unit # by using [0] to [9] on the 10-key. NOTES: • For an all-in-one type entrance station: The door lock is released for the preset time. If the preset release time is “0”, it can be released while the button is pressed and held. For a modular type entrance station: If the VR1 dial (inside the cover) is set to “M (Momentary)”, it can be released while the button is pressed and held. • Depending on the electric door release system that you use, door release may be active only while the door release button is pressed. The list of residential/tenant stations is displayed. Select the target residential/tenant station, then press ). The call is transferred to the residential/tenant station. * "ON HOLD" is displayed on the entrance station and no sound is heard at the entrance station. CAUTION: Be sure to confirm the visitor securely before releasing the door if the entrance station has no camera. When the residential/tenant station answers and accepts the visitor, press or hang up handset to establish communication between the entrance station and the residential/tenant station. * When there is no answer from the residential/tenant station, hang up handset and pick it up again, or press then and to communicate with the entrance station. * Step 2 differs depending on the settings. Reference: Reception mode (→ 8-2 ) When there is a call from an entrance station to a residential/tenant station, it is first transferred to the guard station, so a call tone sounds and the video at the entrance station is displayed on the guard station. - 39 - GUARD STATION 5-3 Operating an optional device You can operate an optional device such as a light on this station. Press ZOOM WIDE ADJUST The optional device turns on. NOTES: • A signal is sent to the device installed in the site. Please refer to the specifications of the device. • If no optional device is installed, nothing happens when the button is pressed. - 40 - GUARD STATION Viewing and adjusting video at an entrance station 5-4 You can view video at the target station when receiving a call from or communicating with an entrance station with a camera, or monitoring it. The video can be adjusted as desired by using the following functions. Pan & Tilt ZOOM ZOOM When a zoom image is displayed, pressing * These functions are not available for a door station. WIDE WIDE ZOOM WIDE ZOOM WIDE , moves the image as shown below. Switching Zoom/Wide The display mode can be switched between zoom and wide by each ZOOM ZOOM press of WIDE WIDE ADJUST ZOOM WIDE ADJUST Wide NOTES: • At night, the object image may be blurred and less-visible when moving the image from right to left or up and down because illumination to the object is reduced. The same applies to a moving object. • The pan & tilt function is not available for a video door station (JO-DV) . Zoom NOTES: • The preset position of zoom image depends on the setting. • When the display mode switches from wide to zoom, the zoom image is displayed at the preset position. • Depending on the properties of the camera, the wide image may appear more distorted than the zoom image but this is not a malfunction. • The image range of the zoom mode and wide mode differs. The edge of wide image will not be displayed with the zoom mode. - 41 - GUARD STATION Adjusting screen view If the video on the screen is difficult to see, you can adjust the screen view. Press ADJUST when the video is difficult to see. ZOOM WIDE ADJUST The backlight or night sensitivity is automatically adjusted. * The discrimination between day and night is performed automatically by this station. * The adjustment result may vary depending on the setting.[Before adjustment] [Before adjustment] [After adjustment] [After adjustment] To restore the screen view before adjustment Press ADJUST again. The icon is cleared and the screen view before adjustment is restored. NOTES: • Pressing at night may make visitors' faces easier to see, but may also make moving objects more difficult to see. • The screen view adjusting function is not available for a video door station (JO-DV). ADJUST - 42 - GUARD STATION MONITORING You can monitor an entrance station or door station. * When monitoring an entrance station or door station with a camera, you can view the video at the station and hear the sound. * The monitoring function is not available for an entrance station or door station without a camera. Press The sound at the station is heard, and the video is displayed on the screen. Selected station number and name 1011 PARKING GATE Monitoring from a tenant building * For monitoring a door station, start from step 5. In standby mode, press ). * While monitoring, you can switch zoom/wide, pan & tilt, and adjust the screen view. (→ 5-4 ) ZOOM ADJUST WIDE [To communicate with the station] The search item list is displayed. ZOOM Select "ENTRANCE" by pressing WIDE WIDE or lift handset. Press ZOOM or ENTRANCE ZOOM WIDE ZOOM ADJUS WIDE ADJUST UNIT BY NUMBER UNIT BY NAME GUARD STATION ENTRANCE or Communication with the station starts and " Press ) or ZOOM WIDE " is displayed. * Until this step, the monitored stations cannot hear any sound from the guard station. The entrance station list is displayed. Select the target entrance station by pressing ZOOM WIDE To end monitoring or communication, ZOOM or WIDE Press or hang up handset. Selected entrance station number and name 0001 ENTRANCE1 NOTES: • Monitoring ends automatically after about 30 seconds. • Only entrance stations that can be selected by the guard station can be monitored. • When no door station is installed, pressing has no effect on the display. ZOOM ADJUST WIDE 0001 0002 0003 0004 0005 1 / 1 ENTRANCE1 ENTRANCE2 ENTRANCE3 ENTRANCE4 ENTRANCE5 Entrance station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press ZOOM ZOOM WIDE or WIDE to turn the page of the list. * The list is displayed in order of either station number or name. - 43 - GUARD STATION Monitoring from a main building Select the target entrance station. Selected entrance station number and name * For monitoring a door station, start from step 7. 0001 ENTRANCE1 In standby mode, press ). ZOOM 0001 0002 0003 0004 0005 Entrance station numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. ZOOM WIDE ADJUST ZOOM Select "ENTRANCE" by pressing WIDE ZOOM or WIDE * Press BUILDING GUARD STATION ENTRANCE ADJUS WIDE ZOOM ZOOM WIDE or to turn the page of the list. WIDE * The list is displayed in order of either station number or name. ENTRANCE ZOOM 1 / 1 ENTRANCE1 ENTRANCE2 ENTRANCE3 ENTRANCE4 ENTRANCE5 ADJUS WIDE The search item list is displayed. Press The sound at the station is heard, and the video is displayed on the screen. Selected station number and name 1011 PARKING GATE Press ZOOM ) or WIDE The building list is displayed. Select the target building. Selected building number and name * While monitoring, you can switch zoom/wide, pan & tilt, and adjust the screen view. (→ 5-4 ) 01 CENTRAL TOWER ZOOM 1 / 1 CENTRAL TOWER EAST TOWER WEST TOWER NORTH TOWER SOUTH TOWER ADJUS WIDE 01 02 03 04 05 [To communicate with the station] Press or lift handset. ZOOM WIDE ADJUST or Building numbers and names are displayed in alphabetical or numerical order. * The arranging method differs depending on the setting. * Press Communication with the entrance station side starts and " is displayed. ZOOM ZOOM or WIDE WIDE to turn the page of the list. * The list is displayed in order of either building number or * Until this step, the monitored stations cannot hear any sound name. Press from the guard station. ) or ZOOM WIDE To end monitoring or communication, The entrance station list is displayed. Press or hang up handset. NOTES: • Monitoring ends automatically after about 30 seconds. • Only entrance stations that can be selected by the guard station can be monitored. • When no door station is installed, pressing has no effect on the display. - 44 - GUARD STATION 7-1 OTHER OPERATIONS Checking for missed calls and calling back If this station fails to respond to a call from a residential/tenant station, "MISSED CALLS" flashes continuously on the display in standby mode, and the status LED on the unit flashes. Check the missed calls and call back if necessary. To call back, select the target unit by pressing ZOOM WIDE ZOOM or WIDE Selected unit # and name * On a guard station in a main section, the building #, building name, and unit # of the selected unit are displayed. Flashes. MISSED CALLS 102 AIPHONE ZOOM ZOOM ADJUST WIDE 101 102 103 201 202 NAME SEARCH ZOOM WIDE EMERGENCY 1 / 1 SMITH AIPHONE DENTIST LAINE MENIN NAME SEARCH MISSED CALLS * Press Flashes. ZOOM ZOOM or WIDE WIDE to turn the page of the list. * Depending on the settings, only the unit # may be displayed. ZOOM To check for missed calls, press mode. WIDE in standby A record of missed calls is displayed. 101 102 103 201 202 ), or lift handset. Communication starts and " ZOOM ADJUST When the call is answered MISSED CALLS 101 SMITH WIDE Press 1 / 1 SMITH AIPHONE DENTIST LAINE MENIN " is displayed. To end communication, press or hang up handset. NOTES: • The guard station can hold up to 20 missed calls. • A record of answered calls is not kept. • While a record of missed calls are displayed, this station cannot enter program mode. When there are two or more missed calls, they are listed in reverse chronological order. * On a guard station in a main section, building #, building names, and unit # are displayed. - 45 - GUARD STATION 7-2 Receiving an emergency call When an emergency alarm switch is locked (or when a wire disconnection occurs), an alarm sounds and an "EMERGENCY" screen is displayed on this station. Check for the unit that sent the emergency call, and take the necessary action. EMERGENCY 101 SMITH The unit # and name of the unit that sent the emergency call * On a guard station in a main section, the building #, building name, and unit # are displayed. To end communication, press up handset. or hang To delete an emergency call from the list. ZOOM Select the target call by pressing then press ZOOM or WIDE WIDE ). EMERGENCY 101 SMITH ZOOM WIDE To stop the alarm sound, press ADJUST 101 201 ). 1 / 1 SMITH LAINE EMERGENCY 101 SMITH ZOOM 1 / 1 SMITH 101 ADJU WIDE NOTE: While a record of emergency calls are displayed, this station cannot enter program mode. The alarm stops and a record of emergency calls is displayed. * On a guard station in a main section, building #, building names, and unit # are displayed. * When linked with multiple guard stations, stopping the alarm on any guard station will stop the alarm of all the guard stations. To communicate with the unit, press ), or lift handset. EMERGENCY 101 SMITH ZOOM 101 ADJU WIDE 1 / 1 SMITH * When there are two or more emergency calls, select one by ZOOM pressing ZOOM or WIDE WIDE , then press ), or lift handset. * Press ZOOM ZOOM WIDE or WIDE to turn the page of the list. * The list is displayed in chronological order. When the call is answered Communication starts and " " is displayed. - 46 - GUARD STATION To display a record of emergency calls NAME SEARCH EMERGENCY ZOOM WIDE NAME SEARCH MISSED CALLS Flashes when there is one or more unchecked emergency calls. Press ZOOM WIDE In standby mode. A record of emergency calls is displayed. To call a room that sent the emergency call ZOOM Select the target record by pressing then press ), WIDE ZOOM or WIDE , and or lift handset. NOTE: The emergency alarm keeps flashing until the target record is deleted from the list. To delete it, select it on the list and then press ). The residential/tenant station keeps sounding the alarm until the emergency alarm switch is restored at the room. In such case, the record of emergency calls cannot be deleted with the guard station. Unless the alarm is restored at the room, no call can be made from the guard station to the room. Please make sure the alarm is restored at the room. NOTES: • If an emergency call is already active on this station and this station is in communication, another guard station cannot interrupt. (An in-use tone will be heard from handset or speaker of the guard station.) • The emergency alarm is given priority even when the system is in use. (Alarms can be activated at the same time for up to 5 units. This excludes GT-2C-L and GT-2C.) • Emergency calls can be made while the system is in use. • With the GT-2C-L and GT-2C, it is possible to transfer to a guard station even when there is a security alarm, depending on the settings. • Even when the call tone volume is set to mute on the guard station, an alarm goes off at the maximum volume. - 47 - GUARD STATION SETTING 8-1 Adjusting display brightness and volumes Adjusting brightness of the display Adjusting the call tone volume You can adjust the call tone volume at this station. In standby mode, press In standby mode, press The SETTINGS screen is displayed. ZOOM WIDE ADJUST ZOOM Select "TONE VOLUME" by pressing WIDE or ZOOM WIDE The SETTINGS screen is displayed. SETTINGS ZOOM Select "BRIGHTNESS" by pressing ZOOM or WIDE WIDE BRIGHTNESS TONE VOLUME ZOOM SETTINGS WIDE ADJUS RECEIVE VOLUME BRIGHTNESS ADVANCED SETTINGS TONE VOLUME ZOOM WIDE ADJUS RECEIVE VOLUME ADVANCED SETTINGS WIDE or WIDE WIDE ADJUS or WIDE BRIGHTNESS TONE VOLUME ZOOM SETTINGS ZOOM WIDE SETTINGS ZOOM ZOOM Adjust the brightness by pressing ZOOM ZOOM Adjust the volume by pressing WIDE ADJUS BRIGHTNESS RECEIVE VOLUME TONE VOLUME ADVANCED SETTINGS RECEIVE VOLUME ADVANCED SETTINGS Adjustment can be made in 4 levels. ("Mute" is available.) * If set to "mute”, the status LED will flash with long intervals. (→ 1-2 ) Adjustment can be made in 10 levels. To return to the previous screen Press To return to the previous screen ). Press To adjust brightness of the display while being called or in communication Press Adjust the brightness by pressing While being called or in communication, press ). ZOOM ZOOM WIDE or ). To adjust the call tone volume while being called or in communication While being called or in communication, press WIDE - 48 - Press Adjust the volume by pressing ZOOM ZOOM WIDE or WIDE GUARD STATION Adjusting the receive volume You can adjust the speaker volume of this station. In standby mode, press The SETTINGS screen is displayed. ZOOM Select "RECEIVE VOLUME" by pressing or WIDE ZOOM WIDE SETTINGS BRIGHTNESS TONE VOLUME ZOOM WIDE ADJUS RECEIVE VOLUME ADVANCED SETTINGS ZOOM ZOOM Adjust the volume by pressing WIDE or WIDE SETTINGS BRIGHTNESS TONE VOLUME ZOOM WIDE ADJUS RECEIVE VOLUME ADVANCED SETTINGS Adjustment can be made in 3 levels. To return to the previous screen Press ). To adjust the receive volume while being called or in communication While being called or in communication, press Press Adjust the volume by pressing ). ZOOM ZOOM WIDE or WIDE - 49 - GUARD STATION 8-2 Switching to reception mode * This section describes the reception mode and how to configure it. Refer to steps 2 to 3 of " 5-1 Transferring a call" for the Switching this station between normal mode and reception mode operating procedure. What is reception mode? In standby mode, press The SETTINGS screen is displayed. In reception mode, all of the calls from entrance stations to residential/tenant stations are first transferred to guard stations. You can transfer the calls to residential/tenant stations after confirming they are not unwanted calls to the target residents. Select "ADVANCED SETTINGS" ZOOM by pressing WIDE ZOOM or [Normal mode] WIDE SETTINGS BRIGHTNESS Call TONE VOLUME ZOOM WIDE ADJUS RECEIVE VOLUME ADVANCED SETTINGS Residential/tenant station Entrance station Guard station (this station) Select "RECEPTION MODE" ZOOM by pressing WIDE ZOOM or WIDE ADVANCED SETTINGS [Reception mode] RECEPTION MODE OFF ZOOM WIDE Call Entrance station ADJUS PROGRAM MODE Transfer Residential/tenant station Guard station (this station) Press ZOOM ) or WIDE Change reception mode to "ON" or "OFF" by ZOOM ZOOM pressing WIDE or WIDE ADVANCED SETTINGS NOTES: • In a main building: Calls from an entrance station are transferred to all guard stations in the building. The call tone sounds on all guard stations at the same time. In a tenant building: Calls from an entrance station are transferred to all guard stations in the tenant building that are linked to the corresponding residential/tenant station. The call tone sounds on all guard stations at the same time. • A call to a residential/tenant station that is not linked to a guard station will result in a call to the residential/tenant station directly. RECEPTION MODE OFF ZOOM WIDE ADJUS PROGRAM MODE ON: Reception mode is active. OFF: Normal mode is active. Press ) or ZOOM WIDE * When this station is in reception mode, the status LED will flash slowly. (→ 1-2 ) To return to the previous screen Press - 50 - ). GUARD STATION Switching to program mode 8-3 * This operation is for Administrators and Managers only Entering a passcord is needed to switch this station into program mode. Ask the system installer for the passcord. * A registered NFC-compliant IC card can be used instead of a passcord. In standby mode, press (or pass an registered NFC-compliant IC card over the NFC reader). The SETTINGS screen is displayed. Select "ADVANCED SETTINGS" ZOOM by pressing WIDE ZOOM or WIDE SETTINGS BRIGHTNESS TONE VOLUME ZOOM WIDE ADJUS RECEIVE VOLUME ADVANCED SETTINGS Select "PROGRAM MODE" ZOOM by pressing WIDE ZOOM or WIDE ADVANCED SETTINGS RECEPTION MODE OFF ZOOM WIDE Press ADJUS PROGRAM MODE ) or ZOOM WIDE The passcord entry screen is displayed. Enter the passcord. * Refer to the GT SYSTEM SETTING MANUAL/Standard & Expanded System for details about the settings. NOTE: An NFC card can be used with either "Admin" or "Manager" authority. (→ GT SYSTEM SETTING MANUAL/Standard & Expanded System) - 51 - GUARD STATION UPDATING RESIDENT INFORMATION Refer to the GT SYSTEM/SETTING MANUAL. • For single building system (→ GT SYSTEM SETTING MANUAL/Standard & Expanded System) • For multi building system (→ GT SYSTEM SETTING MANUAL/Multi Building System) When using an Android device (→ GT SYSTEM SETTING MANUAL/Aiphone GT Setup Tool for Android) Android is a trademark of Google Inc. in the United States and/or other countries. - 52 - FOR PROPER USE OF THIS STATION TECHNICAL PRECAUTIONS • Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use any abrasive cleaner or cloth. CAUTION: Do not use chemicals such as thinner or benzine. In addition, do not use a scrub brush, sandpaper, etc. Otherwise the unit surface could be damaged or discolored. [For guard station only] • The video image may distort when door release is activated. This is not a station malfunction. • If a zoom/wide, pan/tilt, door release operation or brightness adjustment is performed during communication with the entrance station, noise will be produced at the entrance station. This is not a malfunction. [General] • If there is a system malfunction, contact a qualified technician for service. - 53 - FOR PROPER USE OF THIS STATION SPECIFICATIONS 1-call button panel (GF-1P)/2-call button panel (GF-2P)/ 3-call button panel (GF-3P)/4-call button panel (GF-4P) Entrance station (modular type) Camera module (GT-VB) Power source Ambient temperature Material Dimensions Mass Material Supplied from GT-VBC - 10°C - +60°C (+14°F - +140°F) Self-extinguishing PC+ABS resin 108 (W) x 93 (H) x 55 (D) mm 4-1/4" (W) x 3-11/16" (H) x 2-3/16" (D) Approx. 130g (0.29 lbs.) Color Dimensions Mass Camera module panel (GT-VP) Material Color Dimensions Mass Zinc die cast Metallic beige 110 (W) x 95 (H) x 8 (D) mm 4-5/16" (W) x 3-3/4" (H) x 5/16" (D) Approx. 150g (0.34 lbs.) 10-key module panel (GF-10KP) Material Color Audio module (GT-DB/GT-DB-V/GT-DB-VN) Dimensions Power source Ambient temperature Material Mass Dimensions Mass Supplied from GT-BC - 10°C - +60°C (+14°F - +140°F) Self-extinguishing ABS resin 108 (W) x 93 (H) x 53.4 (D) mm 4-1/4" (W) x 3-11/16" (H) x 2-1/8" (D) GT-DB, GT-DB-V: Approx. 210g (0.47 lbs) GT-DB-VN: Approx. 220g (0.49 lbs) Dimensions Mass Power source Ambient temperature Material Dimensions Mass Zinc die cast Metallic beige 109.7 (W) x 94.9 (H) x 7.9 (D) mm 4-5/16" (W) x 3-3/4" (H) x 5/16" (D) Approx. 95g (0.21 lbs) Ambient temperature Material Dimensions Mass Material Color Dimensions DC 24V supplied from a power supply unit (PS-2420 etc.) - 10°C - +60°C (+14°F - +140°F) Self-extinguishing ABS resin 104.6 (W) x 88.3 (H) x 49.1 (D) mm 4-1/8" (W) x 3-1/2" (H) x 1-15/16" (D) Approx. 140g (0.31 lbs) Mass Color Dimensions Mass Material Color Dimensions Mass Panel: Zinc die cast Window: Polycarbonate Bottom: Chrome plated zinc die cast Metallic beige 110 (W) x 96 (H) x 31.2 (D) mm 4-5/16" (W) x 3-3/4" (H) x 1-3/4" (D) Approx. 200g (0.49 lbs.) Dimensions Mass Zinc die cast Metallic beige 110 (W) x 95.2 (H) x 14.3 (D) mm 4-5/16" (W) x 3-3/4" (H) x 9/16" (D) Approx. 190g (0.42 lbs.) 4-module front frame (GF-4F)/3-module front frame (GF-3F)/2-module front frame (GF-2F) Material Color Call switch module (GT-SW) Power source Ambient temperature Material Panel: Zinc die cast Window: Polycarbonate Metallic beige 110 (W) x 95.2 (H) x 14.3 (D) mm 4-5/16" (W) x 3-3/4" (H) x 9/16" (D) Approx. 150g (0.34 lbs.) Blank panel (GF-BP) Name scrolling module panel (GT-NSP-L) Material Supplied from GT-DB/GT-DB-V/GT-DB-VN - 10°C - +60°C (+14°F - +140°F) Self-extinguishing ABS plastic 105.6 (W) x 88.3 (H) x 42.5 (D) mm 4-3/16" (W) x 3-1/2" (H) x1-11/16" (D) Approx. 90g (0.199 lbs.) Address module panel (GF-AP) Name scrolling module (GT-NSB) Power source Panel: Zinc die cast Box: Chrome plated steel Metallic beige 110 (W) x 96.1 (H) x 38.2 (D) mm 4-5/16" (W) x 3-13/16" (H) x 15/16" (D) Approx. 310g (0.69 lbs.) Address module (GF-AD) Audio panel (GT-DBP) Material Color Panel: Zinc die cast Window: Polycarbonate Bottom: Chrome plated zinc die cast Metallic beige 110 (W) x 95.2 (H) x 15.8 (D) mm 4-5/16" (W) x 3-3/4" (H) x 5/8" (D) GF-1P: Approx. 180g (0.40 lbs.) GF-2P: Approx. 190g (0.42 lbs.) GF-3P: Approx. 190g (0.42 lbs.) GF-4P: Approx. 200g (0.45 lbs.) Supplied from GT-DB/GT-DB-V/GT-DB-VN - 10°C - +60°C (+14°F - +140°F) Self-extinguishing ABS plastic 90.5 (W) x 106 (H) x 42.5 (D) mm 3-9/16" (W) x 4-3/16" (H) x 1-11/16" (D) Approx. 90g (0.199 lbs.) Dimensions Mass - 54 - Front frame: Zinc die cast Mounting bracket: Stainless steel Metallic beige GF-2F: 135 (W) x 225 (H) x 16 (D) mm 5-5/16" (W) x 8-7/8" (H) x 5/8" (D) GF-3F: 135 (W) x 320 (H) x 16 (D) mm 5-5/16" (W) x 12-5/8" (H) x 5/8" (D) GF-4F: 135 (W) x 425 (H) x 16 (D) mm 5-5/16" (W) x 16-3/4" (H) x 5/8" (D) GF-2F: Front frame: Approx. 400g (0.89 lbs.) Mounting bracket: Approx. 200g (0.45 lbs.) GF-3F: Front frame: Approx. 490g (1.09 lbs.) Mounting bracket: Approx. 250g (0.56 lbs.) GF-4F: Front frame: Approx. 660g (1.46 lbs.) Mounting bracket: Approx. 290g (0.64 lbs.) FOR PROPER USE OF THIS STATION Entrance station (all-in-one type) All-in-one entrance station (GT-DMB-N/GT-DMB-LVN) DC 24V supplied from a power supply unit (PS-2420 etc.) Ambient temperature - 10°C - +60°C (+14°F - +140°F) Panel: Stainless steel Material Case: Self-extinguishing ABS resin Panel: Stainless steel with hairline finishing Color Case: Black GT-DMB-N: 150 (W) x 320 (H) x 38.5 (D) mm 5-7/8" (W) x 12-5/8" (H) x 1-1/2" (D) Dimensions GT-DMB-LVN: 150 (W) x 425 (H) x 38.5 (D) mm 5-7/8" (W) x 16-3/4" (H) x 1-1/2" (D) GT-DMB-N: Approx. 1,200g (2.70 lbs) Mass GT-DMB-LVN: Approx. 1,500g (3.3 lbs) Power source Guard station Guard station (GT-MKB-N) Power source Communication Ambient temperature Monitor Mounting Material Color Dimensions Mass DC 24V supplied from a power supply unit (PS-2420 etc.) Open voice: Voice-actuated Handset: Voice-actuated/Full-duplex (only when the other side is talking using the handset of GT-MKB-N or GT-1D) 0 - 40°C (+32°F - +104°F) 3.5 inch TFT color LCD Desktop use (with desktop stand) or surface wall-mount Self-extinguishing ABS resin Black 250 (W) x 189 (H) x 59 (D) mm 9-13/16" (W) x 7-7/16" (H) x 2-5/16" (D) Approx. 820g (1.81 lbs) When used with desk stand: Approx. 1,200g (2.70 lbs) Door station Vandal-resistant video door station (surface-mount) (JO-DV) Power source Communication Ambient temperature Material Color Dimensions Mass Remarks Supplied from guard station Open voice hands-free communication - 20°C - +60°C (- 4°F - +140°F) Front panel: Zinc die cast Main unit: Self-extinguishing Front panel: Silver 98 (W) x 173 (H) x 27 (D) mm 3-7/8" (W) x 6-13/16" (H) x 1-1/16" (D) Approx. 650g (1.44 lbs.) IP54, IK08 - 55 - FOR PROPER USE OF THIS STATION SOFTWARE LICENSE Notice regarding software Use of the software installed on this product has received direct or indirect authorization from third parties. (1) GPL/LGPL This product includes software components subject to the GPL/LGPL. Customers can obtain, modify, and re-distribute the source code of the software components according to the GPL/LGPL. Hereafter referred to as the link Open source code This product includes software components subject to the GPL/LGPL, and customers can obtain, modify, and re-distribute the source code of the software components according to the GPL/LGPL. In addition, you can find details on the GPL/LGPL through the following links. http://www.gnu.org/licenses/gpl.html http://www.gnu.org/licenses/lgpl.html Please confirm the following contents when downloading. < > ■ According to GPL/LGPL, the source code of the software components is not guaranteed, including warranty on “merchantability” or “suitability for a particular purpose.” ■ The source code of the software components are according to the “status quo,” and are provided based on the GPL/LGPL. ■ Please understand that we cannot answer questions regarding the content of the source code of the software components. BSD License Copyright (c) 2017, AIPHONE CO.,LTD All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The views and conclusions contained in the software and documentation are those of the authors and should not be interpreted as representing official policies, either expressed or implied, of the FreeBSD Project. - 56 - FOR PROPER USE OF THIS STATION REGULATIONS FCC RED This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Hereby, Aiphone Co., Ltd. declares that the radio equipment type [GT-DB-VN, GT-DMB-N, GT-DMB-LVN, GT-MKB-N, GTBCXB-N] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.aiphone.net/ GT-MKB-N: 13.56MHz / Max. 20.0 dBm GT-DMB-N: 13.56MHz / Max. 20.0 dBm NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: GT-DMB-LVN: 13.56MHz / Max. 20.0 dBm GT-DB-VN: 13.56MHz / Max. 20.0 dBm GT-BCXB-N: 13.56MHz / Max. 20.0 dBm NCC 電信法第48條 低功率電波輻射性電機管理辦法 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或 使用者均不得擅自變更頻率、加大功率或變更原設計之特性及 功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經 INDUSTRY CANADA 發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續 CAN ICES-3 (B)/NMB-3(B) 使用。 This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. 前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻 射性電機設備之干擾。 WEEE The object area of - 57 - is the EU. FOR PROPER USE OF THIS STATION WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of 2 years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. This warranty is limited to the standard specifications listed in the operation manual. This warranty does not cover any supplementary function of a third party product that is added by users or suppliers. Please note that any damage or other issues caused by failure of function or interconnection with Aiphone products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. http://www.aiphone.net/ Issue Date: Jun. 2017 B P0617 SZ 59038 - 58 - AIPHONE CO., LTD., NAGOYA, JAPAN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : UENO Create Date : 2017:05:29 19:51:24+09:00 Modify Date : 2017:06:05 20:09:14+09:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 17.0 (Windows) Creator Tool : Adobe InDesign CC 2015 (Windows) Metadata Date : 2017:06:05 20:09:14+09:00 Format : application/pdf Title : ENG_GT-DMB_MKB_17.05.29.indd Creator : UENO Document ID : uuid:bdb8040d-2735-4242-9237-ab714577079e Instance ID : uuid:187d3f2d-e349-4ebc-9eb3-1f5dc598725c Page Layout : SinglePage Page Count : 58EXIF Metadata provided by EXIF.tools