AIPHONE GTDMBN GT Apartment Intercom System User Manual ENG GT DMB MKB 17 05 29 indd

AIPHONE CO.,LTD. GT Apartment Intercom System ENG GT DMB MKB 17 05 29 indd

Users Manual

Download: AIPHONE GTDMBN GT Apartment Intercom System User Manual ENG GT DMB MKB 17 05 29 indd
Mirror Download [FCC.gov]AIPHONE GTDMBN GT Apartment Intercom System User Manual ENG GT DMB MKB 17 05 29 indd
Document ID3437347
Application IDiJgLRLACCq1cDy5VZV6oVw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize294.28kB (3678482 bits)
Date Submitted2017-06-23 00:00:00
Date Available2017-08-07 00:00:00
Creation Date2017-05-29 19:51:24
Producing SoftwareAcrobat Distiller 17.0 (Windows)
Document Lastmod2017-06-05 20:11:10
Document TitleENG_GT-DMB_MKB_17.05.29.indd
Document CreatorAdobe InDesign CC 2015 (Windows)
Document Author: UENO

GT SYSTEM
Entrance station (modular type)
Entrance station (all-in-one type)
Guard station
OPERATION MANUAL
Entrance station
(modular type)
Guard station
Entrance station
(all-in-one type)
ZOOM
WIDE
ADJUST
Q R
X Y
Thank you for selecting Aiphone for your communication needs. Please read this manual carefully before installation, and keep this in a safe
place for future reference.
Please note that images and illustrations depicted in this manual may differ from the actual product.
PRECAUTIONS
Prohibited
Do not dismantle unit
Keep unit away from water
Be sure to follow the instruction
Notice
WARNING
(Negligence could result in death or serious injury.)
• We will under no conditions be liable for any damages or losses resulting
from this product's contents or specifications.
• We will under no conditions be liable for damage occurring due to the
inability to communicate due to malfunctions, problems, or operational
errors in this product.
• The unit is inoperative during power failure.
• This system is not intended for life support or crime prevention. It is just a
supplementary means of conveying information. Aiphone will under no
conditions be liable for loss of life or property which occurs while the
system is being operated.
• In areas where broadcasting station antennas are close by, this system may
be affected by radio frequency interference.
• Please note the LCD panel, though manufactured with very high precision
techniques, inevitably will have a very small portion of its image elements
always lit or not lit at all. This is not considered a unit malfunction.
• The unit may get slightly warm, but this is not a malfunction.
• During communication, if you speak before the other person has finished
talking, your voice may not come through clearly. Conversation will
proceed smoothly if you speak when the other person has finished talking.
• The entrance station is intended to be mounted on a wall only. It cannot be
used on a desktop.
• Available functions and services are limited according to the specifications
of the installed system.
• If you speak in a fixed tone, the noise-cut function may judge it to be a
noise and cut the transmission, but this is not a malfunction.
• Using a mobile phone or professional-use radio equipment such as walkietalkie close to the system may cause a malfunction.
• Warm-color lighting shining on the camera may change the tint of the
image on the screen.
• The outline of video images displayed may differ from that of the actual
person(s) or background, but this is not a malfunction.
• When the unit’s screen is illuminated with strong light, the image looks
white or silhouetted. But this is not a unit trouble.
• When outside temperature lowers sharply after rainfall, etc., the inside of
the camera may fog up slightly, causing a blurry images, but this is not a
malfunction. Normal operation will be restored when moisture evaporates.
• When using a fluorescent light that shines around the camera, the screen
colors may variously change (color rolling), but it is not a malfunction.
• If the entrance station freezes during winter time, the picture may become
difficult to see or the buttons of the entrance station may not operate.
1. Do not dismantle or alter the unit. Fire or electric shock could result.
2. Do not put any metal and flammable material into the unit through the
openings. Fire, electric shock, or unit trouble could result.
3. Keep the unit away from water or any other liquid. Fire or electric
shock could result.
4. During an electrical storm, do not touch the unit. Electric shock could
result.
5. If there is any smoke, unusual odor, or abnormal sound, or if you drop
or damage the unit, turn off the system power breaker immediately.
Fire or electric shock could result.
6. Do not use power supply with a voltage other than specified. Fire or
electric shock could result
7. Do not use the unit in/under following locations/conditions. If not
observed, it may result in noises or malfunctions.
• Where use of the unit is prohibited, such as in a hospital
• Near an electric medical equipment (e.g. operating rooms, ICU, or
CCU)
• Near automatic control equipment such as auto doors or fire-alarm
boxes
• In the area within 15cm from a cardiac pacemaker
CAUTION
(Negligence could result in injury to people or damage to
property.)
1. Do not put anything on or cover the unit with cloth, etc. Fire or unit
trouble could result.
2. Do not apply high pressure on the screen. If fractured, injury could
result.
3. If the LCD is punctured, do not touch the liquid crystal inside.
Inflammation could result. If contact should occur, flush or rinse area
with water thoroughly and consult your doctor.
4. Be sure to perform a call test with the handset on the hook. If you
operate the hook switch with the handset on your ear, a sudden call etc.
may arrive causing damage to your ear.
5. Do not place your ear near the speaker during use. An unexpected loud
sound could cause hearing damage.
6. When cleaning the wall with a high-pressure water sprayer, be careful
not to spray on the entrance station. If not observed, it may result in fire
or electric shock.
General Precautions
1. Keep the unit more than 1 m (3.3') away from radio or TV set.
2. Keep more than 20 cm (7-7/8") away from other radio equipment, for
example floor heating controller, wireless router or cordless telephone,
etc. It may cause unwanted noise and video distortion.
3. Talk within 30 cm (12'') from this unit. If you are too far away, it may be
difficult to hear audio.
4. When installing and using this unit, protect subject's privacy, portrait
rights, etc. on your own responsibility.
5. As to other manufacturer's devices (such as sensor, detectors, door
releases) used with this system, comply with the Specifications and
Warranty conditions that the manufacturers or venders present.
6. Avoid using this unit in places under direct sunlight. If it is unavoidable,
block out light during use.
7. When putting a hearing aid into T-mode and approaching the unit, the
intercom system may be affected by radio frequency interference etc.,
depending on the installation environment.
8. Please receive and retain all configuration data from the supplier. If you
lose the configuration data, there are cases where maintenance and
after-sales service calls may incur additional setup fees.
10. The area to be monitored by the sensor should be free of obstacles such as
ornamental plants.
-2-
Table of Contents
7 OTHER OPERATIONS ................................................ 45
7-1 Checking for missed calls and calling back ............. 45
7-2 Receiving an emergency call ................................... 46
PRECAUTIONS........................................................... 2
READ THIS BEFORE USING THE STATIONS
8 SETTING........................................................................ 48
8-1 Adjusting display brightness and volumes ............... 48
8-2 Switching to reception mode ................................... 50
8-3 Switching to program mode ..................................... 51
1 SYSTEM CONFIGURATION ........................................ 4
2 NOTES ABOUT USING THIS MANUAL .................... 5
9 UPDATING RESIDENT INFORMATION .................. 52
ENTRANCE STATION
1 PART NAMES AND FUNCTIONS ............................... 6
1-1 Entrance station (modular type) ................................. 6
1-2 Entrance station (all-in-one type)............................... 7
1-3 Indicators.................................................................... 8
FOR PROPER USE OF THIS STATION
1 TECHNICAL PRECAUTIONS .................................... 53
2 SPECIFICATIONS ........................................................ 54
2 OPERATIONS ................................................................. 9
2-1 Calling a resident/tenant or guard station .................. 9
Calling with the call switch module....................... 9
Calling with the name scrolling module ................ 9
Calling with the 10 key module ........................... 10
Calling with the all-in-one type entrance station
(GT-DMB-LVN/GT-DMB-N).............................. 12
2-2 Door release ............................................................. 16
2-3 Other ........................................................................ 16
3 SOFTWARE LICENSE ................................................ 56
4 REGULATIONS ............................................................ 57
5 WARRANTY .................................................................. 58
GUARD STATION
1 PART NAMES AND FUNCTIONS ............................. 17
1-1 Operation panel ........................................................ 17
1-2 Indicators.................................................................. 18
1-3 LCD (display) .......................................................... 19
1-4 Button operations ..................................................... 20
2 RECEIVING A CALL ................................................... 22
2-1 Receiving a call ........................................................ 22
3 CALLING (from a tenant building) ......................... 23
3-1 How to search for a unit to call
(from a tenant building) ........................................... 23
3-2 Calling a unit (residential/tenant station)
or guard station ........................................................ 24
3-3 Calling an entrance station ....................................... 29
4 CALLING (from a main building) ............................ 31
4-1 How to select a unit to call
(from a main building) ............................................. 31
4-2 Calling a room (residential/tenant station)
or guard station ........................................................ 32
4-3 Calling an entrance station ....................................... 37
5 OPERATIONS DURING COMMUNICATION .......... 39
5-1 Transferring a call .................................................... 39
5-2 Door release ............................................................. 39
5-3 Operating an optional device ................................... 40
5-4 Viewing and adjusting video at an entrance
station ....................................................................... 41
6 MONITORING ............................................................... 43
-3-
READ THIS BEFORE USING THE STATIONS
SYSTEM CONFIGURATION
The GT system consists of up to 8 main buildings and 24 tenant buildings.
Main building:
A control section that functions as a main entrance, guard station, security center, administration office, etc. A main building includes no
residential/tenant stations. You can call up all of the residential/tenant stations and guard stations from an entrance station or guard station in the
same system (site).
* A station that is not programmed cannot be called.
* Modular type entrance stations cannot be installed in a main building. Only all-in-one type can be used.
Tenant building:
A section of collective housing. A tenant building includes residential/tenant stations, entrance stations and guard stations. You can call up all of
the residential/tenant stations and guard stations from an entrance station in the same tenant building. However, you cannot call stations in
another tenant building.
Example
: A system (site) consisting of 1 main and 3 tenant buildings
Residential/tenant stations
GT-2C-L/GT-2C
(GT-2H-L/GT-2H)
GT-1C7-L/
GT-1C7
GT-1M3-L/
GT-1M3
GT-1A
GT-1D
Tenant building
Tenant building
Tenant building
Entrance station
(modular type)
Entrance station
(all-in-one type)
GT-DMB-LVN/
GT-DMB-N
Main building
(administration office)
B C
H I
K L
U V
Q R
E F
NO
X Y
Entrance station
(all-in-one type only)
GT-DMB-LVN/
GT-DMB-N
Guard station
GT-MKB-N
-4-
Guard station
GT-MKB-N
READ THIS BEFORE USING THE STATIONS
Coverage of calling, communication and monitoring
The following table shows the coverage of calling, communication, and monitoring from a tenant building and a main building.
NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured.
Incoming call
Other tenant buildings
Same tenant building
Outgoing call
Entrance Guard
st.
st.
Tenant Entrance st. Calling/
communication
building
Guard st.
Calling/
communication
Monitoring
Entrance st. Calling/
Main
communication
building
Guard st.
Calling/
communication
Monitoring
✓ : Possible
Residential/ Entrance Guard
tenant st.
st.
st.
Same main
building
Other main
buildings
Residential/ Entrance Guard Entrance Guard
tenant st.
st.
st.
st.
st.
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
— : Impossible
About the term "building" and "section":
The term "section" is used on the setting screens of entrance
stations and guard stations instead of "building".
"Section" and "building" have the same meaning in this manual.
Setting screen of
guard station
e.g.
CALLING METHOD
Standby screen of
guard station
e.g.
BUILDING #
01
NAME / # SEARCH
SECT LIST+UNIT #
UNIT NUMBER
SECT # + UNIT #
UNIT #
NOTES ABOUT USING THIS MANUAL
This manual describes how to use the entrance stations and guard stations. The use of them differs depending on the building/section (main or
tenant) where they belong. This manual uses the following icons to separate descriptions for the main and tenant buildings.
Icon
Meaning
Main building/section
Tenant building/section
-5-
ENTRANCE STATION
PART NAMES AND FUNCTIONS
1-1
Entrance station (modular type)
Camera module
GT-VB
Name scrolling module
GT-NSB
Display
Back search button
(or move the cursor to the left)
Forward search button
(or move the cursor to the right)
Camera
Call button (or set and move forward)
Illuminator LED
Cancel button (or back)
Q R
10 key module
GT-10K
GT-DB-V
(VIGIK and NFC capable)
GT-DB-VN
10-key (0 to 9,
Audio module
X Y
, #)
(VIGIK capable)
GT-DB
Microphone
IN USE LED (orange)
Call indicator (orange)
Talk indicator (orange)
Door release indicator (green)
NFC reader
Speaker
Call switch module
GT-SW
Call button
Directory card
[Combination examples]
Audio only, Direct select type (8 stations)
Audio/video, Direct select type (8 stations)
GT-VB +
GT-VP
GT-DB(-V, -VN) +
GT-DBP
GT-SW +
GF-4P
GF-BP
Audio only, 10 key type
GT-DB
(-V, -VN) +
GT-DBP
X Y
Q R
Q R
GT-DB
(-V,-VN) +
GT-DBP
GT-VB +
GT-NSB +
GT-VP
GT-NSP-L
GT-10K +
GF-10KP
Audio/video, Direct select type
Audio/video, 10 key type
GT-VB +
GT-VP
GT-NSB +
GT-NSP-L
GT-SW +
GF-4P
GT-DB(-V, -VN) +
GT-DBP
X Y
-6-
GT-10K +
GF-10KP
GT-DB
(-V, -VN) +
GT-DBP
GT-NSB +
GT-NSP-L
GT-SW +
GF-4P
ENTRANCE STATION
1-2
Entrance station (all-in-one type)
All-in-one entrance station
GT-DMB-N
(NFC capable)
Microphone
Camera
Illuminator LED
Talk indicator (orange)
Display
Call indicator (orange)
IN USE LED (orange)
Door release indicator (green)
NFC reader
Speaker
Back search button (or move cursor to the left)
10-key (0 to 9,
, #)
Forward search button
(or move cursor to the right)
Cancel button (or back)
Call button (or set and move forward)
Sensor
(If the sensor detects an object, the display will be illuminated.)
All-in-one entrance station
GT-DMB-LVN
(VIGIK and NFC capable, Hearing aid compatible)
Each part and indicator are the same as GT-DMB-N
except as shown below (VIGIK).
VIGIK (available in France)
-7-
ENTRANCE STATION
1-3
Indicators
Entrance station (modular type)
Entrance station (all-in-one type)
2 3 4
1 2 3
Q R
X Y
Indication patterns
Indicator
1 IN USE LED 2 Call
Status
(orange)
3 Talk
indicator
4 Door
indicator
5 Display
release
indicator
Standby
Off
Off
Off
Off
WELCOME
System in use
Lit
Off
Off
Off
IN
Call
Off
Lit
Off
Off
(*1)
Communication
Off
Off
Lit
Off
(*2)
Releasing a door
Off
Off
Monitoring
Off
Off
Communication is on hold
Lit
Off
(*1)
Off
(*2)
USE
CALLING
SMITH
IN
COMMUNICATION
Lit
DOOR
Off
Off
WELCOME
Off
Off
ON
(*1): Lit when door release is activated during call.
(*2): Lit when door release is activated during communication.
(*3): The display differs depending on the settings.
-8-
(*3)
OPEN
HOLD
(*3)
ENTRANCE STATION
OPERATIONS
: Main building/section
Calling a resident/tenant or guard station
Calling with the call switch module
■ Searching for a unit by scrolling the list
In standby mode, press
and
target unit # and resident name.
to display the
The call indicator will light up and you will hear
a call tone.
* Audio guidance will be heard depending on
the settings.
Press the call button for the unit to be called.
101
SMITH
When the call is answered
Communication starts and the talk indicator
lights up.
* Audio guidance will be heard depending on the settings.
* Depending on the settings, only the resident name may be
displayed.
* The list is displayed in order of either unit # or resident name.
When the door is released
Press
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
Calling with the name scrolling module
2-1
: Tenant building/section
The call indicator will light up and you will hear
a call tone.
* Audio guidance will be heard depending on
the settings.
When the call is answered
Communication starts and the talk indicator
lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
-9-
ENTRANCE STATION
■ Searching for a unit by entering resident
name
Q R
10-key
Calling with the 10 key module
X Y
■ Searching for a unit by entering the unit #
In standby mode, enter the numbers using [0] to
[9] on the 10-key to display the target unit # and
resident name.
In standby mode, press
on the 10-key.
When "ENTER A LETTER" is displayed, enter a
letter using the 10-key to display the target unit #
and resident name.
The number and resident name for the unit whose initial
corresponds to the entered letter will be displayed.
(e.g.) Enter "S".
101
SMITH
Q R
X Y
* Pressing
or
searches for the next unit # and resident
name.
* Depending on the settings, only the resident name may be
displayed.
* When the unit # is set to not be displayed, a letter can be
entered without pressing
* If there is no relevant resident name, "NO ENTRY" is
displayed.
101
SMITH
When the target unit # and resident name is
displayed, press .
NO ENTRY:
The call indicator will light up and you will hear
a call tone.
* Audio guidance will be heard depending on
the settings.
NOTES:
Pressing
or
for approximately 2 seconds will display
resident names in succession.
• If both unit # 111 and 1111 exist, the resident name for unit
111 will be displayed when 1, 1, 1 is entered, and the
resident name for unit 1111 will be displayed if 1 is entered
one more time.
• Stations can be set to display in order by unit #. (The order
starts with the lowest digit from 0 to 9 and then the order
goes by letter.) In cases where unit # such as A101, A201,
A901, A1001, and B101 exist, the order starts with the
lowest digit and goes in the order A101, A201, A901, B101,
A1001.
•
* If there is no relevant unit #, "NO ENTRY" is displayed.
NO ENTRY
* When the residential/tenant station that has been called is in
use, the IN USE LED lights up to indicate that the residential/
tenant station cannot be called.
(In an expanded system, there may be a case that a residential/
tenant station cannot be called even if the IN USE LED is off.)
When the call is answered
Communication starts and the talk indicator
lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
- 10 -
ENTRANCE STATION
When the target unit # or resident name is
displayed, press .
Q R
X Y
The call indicator will light up and you will hear a
call tone.
* Audio guidance will be heard depending on the
settings.
When the call is answered
Communication starts and the talk indicator
lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
- 11 -
ENTRANCE STATION
Calling with the all-in-one type entrance station GT-DMB-LVN/GT-DMB-N
The following diagram shows the screen transitions starting from the standby screen. One of the standby screens shown below is preset to this
station. Find the standby screen of this station from A to E below and confirm the transition from it, and refer to the designated page for the
calling operation.
NOTE:
If "NO ENTRY" is displayed on the screen, press
Standby screen
Display OFF
(black)
* Depending on the setting,
the screen turns on
automatically when you
get closer to this station.
10-key/
/ Turned on automatically
Greeting message
A QUICK LIST
Picture
INFORMATION
101
102
103
201
WELCOME
SMITH
AIPHONE
DENTIST
LAINE
NUMBER
ALPHA
10-key/
10-key/
To the next page B or C
( C is available in a tenant building/section only.)
Call operation screen
B NAME / # SEARCH
D SECT LIST +
C UNIT NUMBER
E SECT# + UNIT#
UNIT#
HOW TO CALL
HOW TO CALL
1. ENTER UNIT #
2. CALL
2. CALL
NUMBER
HOW TO CALL
HOW TO CALL
1. SELECT UNIT
1. BUILDING LIST
2. SELECT
3. ENTER UNIT #
4. CALL
1. ENTER BLDG. #
2. SELECT
3. ENTER UNIT #
4. CALL
ALPHA
10-key
10-key
10-key
ENTER UNIT #
UNIT LIST
UNIT #
101
SMITH
BUILDING LIST
ENTER BUILDING #
01
CENTRAL TOWER
BUILDING #
SELECT
ENTER
ALPHA
CALL
CANCEL
To the next page B
CALL
ALPHA
CANCEL
To the next page C
CANCEL
To the next page D
- 12 -
CANCEL
To the next page E
ENTRANCE STATION
Confirming the target unit in the quick list
Entering unit #
NOTE: Entering unit # can only be performed on this screen.
Unit # and resident names frequently called are preset to be
displayed in the quick list.
Entering resident name is not possible.
HOW TO CALL
* Up to 4 units can be displayed.
1. ENTER UNIT #
INFORMATION
Unit #
101
102
103
201
2. CALL
SMITH
AIPHONE
DENTIST
LAINE
When the target unit number is numerals
only
ALPHA
NUMBER
Resident name
In standby mode, press
and
to display the
target unit, or 10-key to change the standby
screen.
In standby mode, enter numbers using [0] to [9]
on the 10-key to display the target unit #.
* The 10-key can be used even after pressing
or
ENTER UNIT #
UNIT #
ALPHA
CALL
or
CANCEL
* Depending on the system, only the resident name may be
displayed.
The "UNIT LIST" screen B or "ENTER UNIT #" screen C is
displayed.
* If you have entered a wrong number, press
to return to
standby mode.
Follow the operating procedure of either B or C
depending on the displayed screen.
When the target unit # is displayed, press
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of 2-1 for details.
* C is available in a tenant building/section only.
When the target unit number is alphanumeric
Searching for a unit in the unit list
In standby mode, press
on the 10-key.
* The 10-key can be used even after pressing
HOW TO CALL
1. SELECT UNIT
or
ENTER UNIT #
UNIT #
2. CALL
NUMBER
NUMBER
ALPHA
ALPHA
CALL
CANCEL
In standby mode, press
and
or 10-key to
display the target unit # and resident name.
UNIT LIST
101
SMITH
Enter letters using the 10-key to display the
target unit #.
* Refer to the next page for how to enter letters.
CALL
CANCEL
or
The 10-key can be used to enter unit #, or by pressing
the 10-key can be used to enter letters (resident name).
, then
When the target unit # is displayed, press
* Depending on the settings, only the resident name may be
displayed.
* The list is displayed in order of either unit # or resident name.
* If you have entered a wrong number, press
to return to
standby mode.
When the target unit is displayed, press
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of 2-1 for details.
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of 2-1 for details.
- 13 -
ENTRANCE STATION
How to enter letters
(e.g.) Entering "CATHY"
1. To enter "C", press
2. Press
Searching for a building in the building list
and entering unit #
HOW TO CALL
three times.
1.BUILDING LIST
2.SELECT
3.ENTER UNIT #
4.CALL
(*1)
once.
3. To enter "A", press
once.
4. To enter "T", press
once.
5. To enter "H", press
twice.
6. To enter "Y", press
three times.
In standby mode, press
and
to display the
target building number and name.
BUILDING LIST
(*1): This step is needed for entering different letters with the same
01
CENTRAL TOWER
key sequentially.
SELECT
CANCEL
To enter a special character
, : Press
once.
- : Press
twice.
. : Press
three times.
/ : Press
four times.
When the target building is displayed, press
Enter numbers or letters using the 10-key to
display the target unit #.
five times.
Space : Press
* For entering numbers or letters, follow steps 1 and 2 of
Æ : Press
six times.
Ø : Press
seven times.
C -
Å : Press
eight times.
or
"When the target unit number is numerals only"
"When the target unit number is alphanumeric".
ENTER UNIT #
* If you have entered a wrong letter, press
01
CENTRAL TOWER
UNIT #
101
to return to
standby mode.
CALL
ALPHA
When the target unit # is displayed, press
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of 2-1 for details.
- 14 -
ENTRANCE STATION
Entering a building # and unit #
When the target unit is successfully
called
HOW TO CALL
The call indicator will light up and you will hear
a call tone.
* Audio guidance will be heard depending on the settings.
1.ENTER BLDG#
2.SELECT
3.ENTER UNIT #
4.CALL
When the call is answered
In standby mode, enter numbers or letters using
the 10-key to display the target building.
Communication starts and the talk indicator
lights up.
* Audio guidance will be heard depending on the settings.
* For entering numbers or letters, follow steps 1 and 2 of
C or
"When the target unit number is numerals only"
"When the target unit number is alphanumeric".
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
ENTER BUILDING #
BUILDING #
01
ALPHA
ENTER
NOTES:
CANCEL
If "DENIED" is displayed or returns to standby mode,
the entered unit #/resident name is not registered.
• Enter the target unit # exactly. Otherwise, "DENIED" is
displayed or returns to standby mode.
• If both unit # 111 and 1111 exist, the resident name for
unit 111 will be displayed when 1, 1, 1 is entered, and
the resident name for unit 1111 will be displayed if 1 is
entered one more time.
• Stations can be set to be displayed in order by unit #.
(The order starts with the lowest digit from 0 to 9 and
then the order goes by letter.) In cases where unit # such
as A101, A201, A901, A1001, and B101 exist, the order
starts with the lowest digit and goes in the order A101,
A201, A901, B101, A1001.
•
When the target building number is displayed,
press
Enter numbers or letters using the 10-key to
display the target unit #.
* For entering numbers or letters, follow steps 1 and 2 of
C or
"When the target unit number is numerals only"
"When the target unit number is alphanumeric".
ENTER UNIT #
BUILDING #
01
UNIT #
101
CALL
ALPHA
When the target unit # is displayed, press
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of 2-1 for details.
- 15 -
ENTRANCE STATION
2-2
Door release
■ Door release by using the access code
■ Door release by an NFC-compliant IC card,
etc.
* The access code is preset by the system installer or
administrator.
A card incorporated with an NFC tag can be used to release a door.
To use, the ID of the NFC tag must be registered as a door release
code.
In standby mode, enter [#] and then the access
code (4 to 6 digits) using [0] to [9] on the 10-key.
[Modular type]
[All-in-one-type]
Pass an NFC-compliant IC card over the NFC
reader.
[Modular type]
Q R
NFC reader
[All-in-one-type]
X Y
(e.g.)
When the access code is "4567", enter "#", "4", "5", "6", "7".
* Put the card within 10 mm of the NFC reader. Otherwise, the
code may not be read correctly.
The door is released.
The door is released.
• The door release indicator lights up.
• Audio guidance will be heard depending
on the settings.
• The door release indicator lights up.
• Audio guidance will be heard depending
* If there is no relevant number, "DENIED" is displayed.
* Door release is enabled even while the IN USE LED is lit.
on the settings.
* Door release is enabled even while the IN USE LED is lit.
NOTE: Do not overlap IC cards when passing them over the
NFC reader. The code may not be read correctly.
2-3
Other
* Calling from an entrance station is disabled while the IN USE LED is lit.
Wait until the IN USE LED turns off.
NOTE: For a multi building system with lift control, if you unlock from a
room and terminate call at the same time, the entrance station may
not unlock properly.
- 16 -
GUARD STATION
PART NAMES AND FUNCTIONS
1-1
Operation panel
Color LCD monitor (Display)
Handset
Status LED (orange)
Speaker
Indicates the current status of this
station by lighting up or flashing on/off
in orange (while initializing the system,
being called, communicating, etc.).
Multi-function buttons
•
•
•
•
LIGHT
VIDEO CALL
LIST
SETTING
NFC reader
Reset button
10-key (0 to 9,
, #)
ZOOM
WIDE
Option button
ADJUST
Microphone
OFF button
ADJUST button
ZOOM/WIDE button
MONITOR button
(up)
(left)
(right)
(down)
TALK button
Door release (
- 17 -
) button
GUARD STATION
1-2
Indicators
ZOOM
WIDE
ADJUST
Indication patterns
Status
Indicator
6 Status LED (orange)
Standby
Off
Standby
(Call tone volume: off)
Long interval flashing
Standby
(Reception mode: on)
Slow flashing
This station is in use by another station
(this station is inoperable)
Off
Being called by an entrance station
Fast flashing
(0.5 sec.)
(0.5 sec.)
(0.5 sec.)
Being called by a door station
(2.5 sec.)
(0.5 sec.)
Normal flashing
(1 sec.)
Being called by a door bell
(5.5 sec.)
(1 sec.)
Fast flashing
(0.5 sec.)
Monitoring an entrance station
Lit
Communicating with an entrance station
Lit
Calling another guard station or residential/tenant station
(including in reception mode)
Fast flashing
Sounding an emergency alarm
Fast flashing
(0.5 sec.)
(0.5 sec.)
(1 sec.)
(0.5 sec.)
(0.5 sec.)
A new list of missed calls from residential/tenant stations
has arrived
Slow flashing
Error indication
Off
(An error message is displayed.)
Communication is on hold
Off
(0.5 sec.)
- 18 -
(2.5 sec.)
GUARD STATION
1-3
LCD (display)
The following are samples of typical screens and icons.
In standby mode
* When nothing is displayed (black) on the screen, the screen below can be displayed by pressing
any key other than
, 0-9,
or lifting the handset.
Status display icons
NAME SEARCH
ZOOM
WIDE
The following icons are displayed here depending on the status of this
station.
Icon
EMERGENCY
The status when the icon appears
Appears when this station is in reception mode.
NAME SEARCH
MISSED CALLS
Appears while searching for a unit.
Appears while the number or letter entry screen is
displayed.
Appears while receiving a call.
Appears when a record of missed calls is displayed.
Appears while in communication.
Appears while transferring.
Appears while this station is in communication with a
residential/tenant station after transferring a call from an
entrance station to the residential/tenant station.
NAME SEARCH screen
The screen for searching for a unit by its name.
Appears when a record of emergency calls is displayed.
Appears while monitoring.
List page number
When the list of units or setting items consists of two
or more pages, the current page number is shown
here.
Appears while a wide video at the entrance or a video at
the door station is displayed.
Appears while a zoom video at the entrance station is
displayed.
Appears when the setting screen is displayed.
Information display
Displays the unit # or resident name of selected station,
operation method, etc.
NAME SEARCH
101
102
103
201
202
1 /8
SMITH
AIPHONE
DENTIST
LAINE
MENIN
List of units
The list of units you searched for is shown here by
their unit # and resident names. Nothing appears in
the list when no corresponding unit is detected.
NOTE: The above display example may differ from the actual one.
- 19 -
GUARD STATION
1-4
Button operations
■ Multi-function buttons and icons
The functions to be performed by the multi-function buttons are displayed by icons just above the buttons.
Multi-function buttons
Functions shown by icons here can be performed by
pressing the buttons just below the icons. The icons vary
depending on the status of this station.
When the same icon as the icon above a button is
displayed, the button performs the function shown by the
button name.
Displays the setting screen.
Turns on the light at an entrance station.
(e.g.)
Pressing
adjusts receive volume (
).
Starts communication with the preset
entrance station, or displays video from a
surveillance camera.
Displays the search item list.
(e.g.)
restores the previous screen (
Pressing
).
Icons and their functions
Icons and their functions for each multi-function button are as follows.
Icon
Function
Icon
Determines the choice.
Function
Changes the 10-key to the letter entry mode.
Turns the entrance light on (when light is installed in
common area).
Adjusts brightness.
Changes the 10-key to the number entry mode.
Turns off the emergency alarm.
Adjusts receive volume.
Displays the search item list.
Calls the selected unit.
Transfers a call from entrance station to residential/tenant
station.
Adjusts call tone volume.
Restores the previous screen.
Displays the setting screen.
Cancels the choice.
Turns off overlay.
Calls the preset entrance station directly.
Deletes the selected item.
- 20 -
GUARD STATION
■ How to enter numbers and letters by using the 10-key (0 to 9, , #)
Use the 10-key in the number or letter entry mode.
The number and letter entry modes can be switched by pressing
).
Number entry mode
UNIT #
Entered numbers are displayed.
ZOOM
WIDE
ADJUST
Letter entry mode
UNIT #
How to enter letters
To enter a special character
(e.g.) Entering "CATHY"
1. To enter "C", press
ZOOM
2. Press
WIDE
once.
three times.
(*1)
, : Press
once.
- : Press
twice.
. : Press
three times.
four times.
3. To enter "A", press
once.
/ : Press
4. To enter "T", press
once.
Space : Press
5. To enter "H", press
twice.
6. To enter "Y", press
three times.
(*1): This step is needed for entering different letters with the same
five times.
Æ : Press
six times.
Ø : Press
seven times.
Å : Press
eight times.
key sequentially.
* If you have entered a wrong letter, press
to standby mode.
- 21 -
to return
GUARD STATION
RECEIVING A CALL
: Main building/section
: Tenant building/section
Receiving a call
2-1
When receiving a call, the call tone
sounds and the number and name of
the caller (station) are displayed in the
screen.
ZOOM
WIDE
ADJUST
Caller
The caller can be confirmed on the display.
A call from a residential/
tenant station or another
guard station
The unit # and station name
A call from an entrance
station with a camera
A call from an entrance
station without a camera
The number and
entrance name
The number and entrance
name
101
DR.DOUIEB,PATRI
1011
PARKING GATE
A call from a door station
10
ENTRANCE1
DOOR STATION
The video at the entrance
The video at the door station
NOTE: When receiving a call from a door bell, nothing is displayed on the screen and answering is not possible.
Answering a call
To answer a call
* While communicating with the caller, unlock the door or use
the other features by pressing the following buttons.
Press
Adjusting display brightness (→ 8-1 )
or lift handset.
Adjusting call tone
volume (→ 8-1 )
1011
PARKING GATE
ZOOM
WIDE
Adjusting receive
volume (→ 8-1 )
ADJUST
or
Operating an optional
device (→ 5-3 )
ZOOM
WIDE
Begin communication with the caller.
ADJUST
Adjusting screen view
(→ 5-4 )
Door release
(→ 5-2 )
* Lift handset at any time for privacy.
Pan/tilt (→ 5-4 )
Zoom/wide (→ 5-4 )
To end communication
Press
or hang up handset.
Communication ends automatically after 3 minutes.
* Communication with a residential/tenant station in hands-free
mode ends automatically after 1 minute in hands-free mode.
- 22 -
GUARD STATION
CALLING (from a tenant building)
How to search for a unit to call (from a tenant building)
3-1
The following methods are available in standby mode to search for a unit (residential/tenant station) or guard station to call.
Searching by number
Searching by name
Using the search item list
* When nothing is displayed (black) on the screen, press any key other than
mode.
, 0-9,
or lift handset to enter standby
* An entrance station can be searched for by using method C only.
Standby mode
NAME SEARCH
ZOOM
WIDE
EMERGENCY
NAME SEARCH
MISSED CALLS
ZOOM
WIDE
Searching by number
(→ 3-2 )
NUMBER SEARCH
Searching by name
(→ 3-2 )
ADJUST
Using the search item list
(→ 3-2 )
UNIT BY NUMBER
101
SMITH
101
102
103
104
105
1 / 4
SMITH
AIPHONE
DENTIST
YOKOI
YABE
101
102
103
201
202
1 / 1
SMITH
AIPHONE
DENTIST
LAINE
MENIN
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
• Searching by number (UNIT BY
NUMBER) (→ 3-2 )
• Searching by name (UNIT BY NAME)
(→ 3-2 )
• Searching a guard station from the
guard station list (GUARD STATION)
(→ 3-2 )
• Searching an entrance station from the
entrance station list (ENTRANCE)
(→ 3-3 )
- 23 -
GUARD STATION
Coverage of calling from a guard station in a tenant building
NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured.
Same tenant building
Outgoing call
Entrance st. Guard
st.
Tenant Guard st.
building
3-2
✓
Residential/
tenant st.
✓
✓
Calling a unit (residential/tenant station) or guard station
Searching for a unit by number
In standby mode, enter numbers using [0] to [9]
on the 10-key to display the target unit # and
resident name.
Unit # whose initial number matches the
entered number are displayed in the list.
* The list is displayed in order of unit #.
* This station is not displayed.
Select the target unit by pressing
ZOOM
WIDE
ZOOM
or
WIDE
ZOOM
WIDE
* Press
ADJUST
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
),
or lift handset.
When the call is answered
Communication starts and "
or hang
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to be displayed in order by unit #. (The order
starts with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
1 / 4
SMITH
AIPHONE
DENTIST
YOKOI
YABE
101
102
103
104
105
To end communication, press
up handset.
NOTES:
Press
Entrance st. Guard
st.
Guard
st.
— : Impossible
NUMBER SEARCH
Entrance
st.
✓
Entered number(s)
Main building
Calling/
communication
✓
✓ : Possible
Residential/
tenant st.
Incoming call
Other tenant buildings
" is displayed.
- 24 -
GUARD STATION
Searching for a unit by name
ZOOM
In standby mode, press
ZOOM
or
WIDE
WIDE
The search screen is displayed.
ZOOM
Select the target unit by pressing
WIDE
ZOOM
or
WIDE
Selected unit # and resident name
101
SMITH
ZOOM
ADJUS
WIDE
101
102
103
201
202
1 / 1
SMITH
AIPHONE
DENTIST
LAINE
MENIN
Unit # and resident names are displayed in
alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either unit # or name.
* This station is not displayed.
Press
),
or lift handset.
When the call is answered
Communication starts and "
" is displayed.
To end communication, press
up handset.
or hang
NOTES:
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• Stations can be set to be displayed in order by unit #. (The order
starts with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
- 25 -
GUARD STATION
Searching for a unit by using the search item list
Press
).
UNIT BY NUMBER
The search item list is displayed.
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
Searching for a unit by unit #
ZOOM
Select "UNIT BY NUMBER" by pressing
WIDE
or
ZOOM
WIDE
Press
),
or lift handset.
When the call is answered
Communication starts and "
" is displayed.
UNIT BY NUMBER
ADJUS
WIDE
Press
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
ZOOM
) or
ZOOM
WIDE
The "NUMBER SEARCH" screen is displayed.
Enter numbers using [0] to [9] on the 10-key to
display the target unit # and resident name.
Entered unit #
NUMBER SEARCH
101
102
103
104
105
1 / 4
SMITH
AIPHONE
DENTIST
YOKOI
YABE
Unit # whose initial number matches the
entered number are displayed in the list.
* The list is displayed in order of unit #.
* This station is not displayed.
Select the target unit by pressing
ZOOM
WIDE
ZOOM
or
* Press
WIDE
ZOOM
ZOOM
WIDE
or
WIDE
to turn the page of the list.
- 26 -
To end communication, press
up handset.
or hang
GUARD STATION
Searching for a unit by resident name
ZOOM
Select "UNIT BY NAME" by pressing
Press
),
or lift handset.
ZOOM
or
WIDE
WIDE
When the call is answered
UNIT BY NAME
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
ZOOM
ADJUS
WIDE
Press
Communication starts and "
) or
ZOOM
WIDE
The "NAME SEARCH" screen is displayed.
Enter an alphabetical character using [0] to [9] on
the 10-key to display the target resident name.
Entered character
NAME SEARCH
102
1 /1
AIPHONE
The unit # and resident names whose initial letter
matches the entered letter are displayed in the list.
(e.g.) When "A" is entered, 301A, 1003ABC,
ABC, etc. are displayed in the list.
* The arranging method differs depending on the
setting.
* The list is displayed in order of name.
* This station is not displayed.
ZOOM
Select the target unit by pressing
WIDE
ZOOM
or
WIDE
ZOOM
ADJUS
WIDE
* Press
ZOOM
ZOOM
WIDE
or
WIDE
to turn the page of the list.
- 27 -
" is displayed.
To end communication, press
up handset.
or hang
GUARD STATION
Searching for a guard station from the guard
station list
Searching for an entrance station
(→ 3-3 )
ZOOM
Select "GUARD STATION" by pressing
WIDE
or
ZOOM
WIDE
NOTES:
GUARD STATION
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
ZOOM
ADJUS
WIDE
Press
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to be displayed in order by unit #. (The order
starts with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
) or
ZOOM
WIDE
The guard station list is displayed.
ZOOM
Select the target guard station by pressing
WIDE
ZOOM
or
WIDE
001
GUARD1
ZOOM
ADJUS
WIDE
001
002
003
1 / 1
GUARD1
GUARD2
GUARD3
Guard station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either station number or name.
* This station is not displayed.
Press
),
or lift handset.
When the call is answered
Communication starts and "
" is displayed.
To end communication, press
up handset.
or hang
- 28 -
GUARD STATION
Calling an entrance station
3-3
Direct calling an entrance station
Press
).
(only when
The search item list is displayed.
is displayed in standby
mode)
When
is displayed, press
).
ZOOM
The preset entrance station is called, and then communication is
enabled.
ADJUST
WIDE
ZOOM
Select "ENTRANCE" by pressing
WIDE
WIDE
ENTRANCE
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
ZOOM
ADJUS
WIDE
Press
) or
ZOOM
WIDE
The entrance station list is displayed.
Select the target entrance station by pressing
ZOOM
WIDE
ZOOM
or
WIDE
Selected entrance station number and name
0001
ENTRANCE1
ZOOM
ADJUST
WIDE
0001
0002
0003
0004
0005
1 / 1
ENTRANCE1
ENTRANCE2
ENTRANCE3
ENTRANCE4
ENTRANCE5
Entrance station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either station number or name.
Press
),
Communication starts and "
or lift handset.
" is displayed.
To end communication, press
up handset.
Talk hands-free or lift the handset.
ZOOM
or
or hang
NOTE: Communication will end automatically after approximately
3 minutes.
- 29 -
To end communication, press
up handset.
or hang
GUARD STATION
Transferring video image taken by an
entrance station camera or surveillance
camera to a residential/tenant station
(only when
is displayed in standby
mode)
Press
).
Select a residential/tenant station by one of
the following methods A - C .
A Press
ZOOM
) and then
WIDE
ZOOM
or
WIDE
to
select the target residential/tenant station.
B 1 Enter a number by using the 10-key to
display the list of residential/tenant
stations that include the number.
2 Press
ZOOM
ZOOM
or
WIDE
WIDE
to select the target
residential/tenant station.
3 Press
C 1 Press
) or
ZOOM
WIDE
and enter a letter by using the
10-key to display the list of residential/
tenant stations that include the letter.
2 Press
ZOOM
WIDE
ZOOM
or
WIDE
to select the target
residential/tenant station.
3 Press
) or
ZOOM
WIDE
Press
When the resident/tenant station answers and
).
accepts the visitor, press
handset.
or hang up
* Step 2 differs depending on the settings.
- 30 -
GUARD STATION
CALLING (from a main building)
How to select a unit to call (from a main building)
4-1
The following methods are available in standby mode to select a room (residential/tenant station) or guard station to call.
Searching by number
Searching for a unit in the list
Entering unit #
Searching for a building in the list + entering unit #
Entering a building # + unit #
* Any of 1 to 4 are available by default.
Using the search item list
* When nothing is displayed (black) on the screen, press any key other than
mode.
, 0-9,
or lift handset to enter standby
* To return to the standby screen, press
* An entrance station can be searched for by using the method
C only.
Standby mode
UNIT #
ZOOM
WIDE
EMERGENCY
UNIT #
MISSED CALLS
NAME SEARCH
ZOOM
WIDE
EMERGENCY
NAME SEARCH
MISSED CALLS
BUILDING
ZOOM
WIDE
EMERGENCY
BUILDING
MISSED CALLS
ZOOM
ADJUST
WIDE
Searching by number
(→ 4-2 )
NUMBER SEARCH
B-1
B-2
101
102
103
104
105
1 / 4
SMITH
AIPHONE
DENTIST
YOKOI
YABE
B-3
B-4
Searching for a unit in
the list (→ 4-2 )
Entering unit #
(→ 4-2 )
Searching for a
building in the list +
unit # (→ 4-2 )
Entering a building # +
unit # (→ 4-2 )
Using the search item list
(→ 4-2 )
BUILDING
BUILDING
GUARD STATION
ENTRANCE
• Searching for a building in the list +
entering unit # or Entering a building #
+ unit # (→ 4-2 )
• Searching a guard station from the
guard station list (GUARD STATION)
(→ 4-2 )
• Searching an entrance station from the
- 31 -
entrance station list (ENTRANCE)
(→ 4-3 )
GUARD STATION
Coverage of calling from a guard station in a main building
NOTE: Performance depends on the settings. If you cannot call even when ✓ is indicated, its setting is not configured.
Tenant building
Outgoing call
Entrance
st.
Main
Guard st.
building
Guard
st.
Residential/
tenant st.
Incoming call
Same main building
Other main buildings
Entrance st. Guard st.
Entrance st. Guard st.
Calling/
communication
✓
✓
✓
✓
✓
✓
✓
✓ : Possible
4-2
Calling a room (residential/tenant station) or guard station
A Searching for a unit by number
In standby mode, enter numbers using [0] to [9]
on the 10-key to display the target unit # and
name.
Press
),
or lift handset.
When the call is answered
Communication starts and "
" is displayed.
Entered number(s)
NUMBER SEARCH
101
102
103
104
105
1 / 4
SMITH
AIPHONE
DENTIST
YOKOI
YABE
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to display in order by unit #. (The order starts
with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
* The list is displayed in order of unit #.
* This station is not displayed.
ZOOM
Select the target unit by pressing
WIDE
ZOOM
or
WIDE
ZOOM
WIDE
* Press
WIDE
ADJUST
ZOOM
ZOOM
or
WIDE
or hang
NOTES:
Unit # whose initial number matches the
entered number are displayed in the list.
To end communication, press
up handset.
to turn the page of the list.
- 32 -
GUARD STATION
B-1 Searching for a unit in the list
ZOOM
In standby mode, press
B-2 Entering unit #
ZOOM
or
WIDE
WIDE
The unit list is displayed.
ZOOM
In standby mode, press
ZOOM
or
WIDE
WIDE
"UNIT #" screen is displayed.
ZOOM
Select the target unit, by pressing
WIDE
ZOOM
or
WIDE
[When the target unit number is numerals only]
Enter the unit # using [0] to [9] on the 10-key.
Selected unit # and name
[When the target unit number is alphanumeric]
101
SMITH
ZOOM
ADJUS
WIDE
101
102
103
201
202
1 Press
( ).
2 Enter the resident name using [0] to [9] on
1 / 1
SMITH
AIPHONE
DENTIST
LAINE
MENIN
the 10-key.
* How to enter letters (→P. 21).
Entered number is displayed.
UNIT #
Unit # and names are displayed in alphabetical
or numerical order.
* The arranging method differs depending on
the setting.
* Press
10
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either unit # or name.
* This station is not displayed.
Press
),
or lift handset.
Press
),
When the call is answered
When the call is answered
Communication starts and "
" is displayed.
* Audio guidance will be heard depending on the settings.
Communication starts and "
To end communication, press
up handset.
or hang
or lift handset.
" is displayed.
To end communication, press
up handset.
or hang
NOTES:
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to display in order by unit #. (The order starts
with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
NOTE: Communication will end automatically after approximately
3 minutes. Communication with a residential/tenant station
in hands-free mode ends automatically after 1 minute in
hands-free mode.
- 33 -
GUARD STATION
B-3 Searching for a building in the list +
entering unit #
ZOOM
In standby mode, press
B-4 Entering a building # + unit #
or
WIDE
WIDE
ZOOM
Select the target building by pressing
WIDE
or
ZOOM
WIDE
01
CENTRAL TOWER
WIDE
01
02
03
04
05
[When the target building number is numerals
only]
Enter the building number using [0] to [9] on the
10-key.
1 Press
).
2 Enter the building name using [0] to [9] on
1 / 1
CENTRAL TOWER
EAST TOWER
WEST TOWER
NORTH TOWER
SOUTH TOWER
ADJUS
WIDE
[When the target building number is
alphanumeric]
Selected building number and name
ZOOM
ZOOM
or
WIDE
"BUILDING #" screen is displayed.
The building list is displayed.
ZOOM
In standby mode, press
ZOOM
the 10-key.
* How to enter letters (→P. 21).
Entered number is displayed.
BUILDING #
Building numbers and names are displayed in
alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either building number or
name.
Press
) or
ZOOM
WIDE
) or
ZOOM
WIDE
"UNIT #" is displayed.
"UNIT #" is displayed.
Press
[When the target unit number is numerals only]
Enter the unit # using [0] to [9] on the 10-key.
[When the target unit number is numerals only]
Enter the unit # using [0] to [9] on the 10-key.
[When the target unit number is alphanumeric]
[When the target unit number is alphanumeric]
1 Press
).
2 Enter the resident name using [0] to [9] on
1 Press
).
2 Enter the resident name using [0] to [9] on
the 10-key.
the 10-key.
* How to enter letters (→P. 21).
* How to enter letters (→P. 21).
Selected building is displayed.
BUILDING #
01
CENTRAL TOWER
01
UNIT #
UNIT #
Entered number is displayed.
Entered number is displayed.
Press
),
or lift handset.
),
or lift handset.
When the call is answered
When the call is answered
Communication starts and "
Press
Communication starts and "
" is displayed.
To end communication, press
up handset.
or hang
- 34 -
" is displayed.
To end communication, press
up handset.
or hang
GUARD STATION
Entering a building # + unit #
C Searching for a unit by using the search item
list
Searching for a building in the list + entering
unit #
Press
Press
).
The search item list is displayed.
ZOOM
Select "BUILDING" by pressing
).
WIDE
ZOOM
or
WIDE
BUILDING
The search item list is displayed.
BUILDING
GUARD STATION
ENTRANCE
ZOOM
ZOOM
Select "BUILDING" by pressing
WIDE
ZOOM
or
WIDE
WIDE
ADJUS
BUILDING
BUILDING
GUARD STATION
ENTRANCE
ZOOM
WIDE
ADJUS
Press
) or
ZOOM
WIDE
"BUILDING #" screen is displayed.
Press
) or
ZOOM
WIDE
NOTES:
The building list is displayed.
Follow steps 2 to 6 of B-4 .
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to display in order by unit #. (The order starts
with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
Follow steps 2 to 6 of B-3 .
- 35 -
GUARD STATION
Searching for a guard station from the guard
station list
ZOOM
Select the target guard station by pressing
WIDE
ZOOM
or
Press
WIDE
).
The search item list is displayed.
01
CENTRAL TOWER
001
GUARD1
1 / 1
001
GUARD1
002
GUARD2
003
GUARD3
ZOOM
Select "GUARD STATION" by pressing
WIDE
or
ZOOM
ADJUS
WIDE
ZOOM
WIDE
GUARD STATION
BUILDING
GUARD STATION
ENTRANCE
ZOOM
ADJUS
WIDE
Guard station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
Press
ZOOM
) or
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either station number or name.
* This station is not displayed.
WIDE
ZOOM
ZOOM
The building list is displayed.
ZOOM
Select the target building by pressing
WIDE
or
),
or lift handset.
When the call is answered
ZOOM
WIDE
Press
Communication starts and "
" is displayed.
Selected building number and name
01
CENTRAL TOWER
ZOOM
1 / 1
CENTRAL TOWER
EAST TOWER
WEST TOWER
NORTH TOWER
SOUTH TOWER
ADJUS
WIDE
01
02
03
04
05
• Communication will end automatically after approximately 3
minutes. Communication with a residential/tenant station in
hands-free mode ends automatically after 1 minute in hands-free
mode.
• If both unit # 111 and 1111 exist, the resident name for unit 111
will be displayed when 1, 1, 1 is entered, and the resident name
for unit 1111 will be displayed if 1 is entered one more time.
• Stations can be set to display in order by unit #. (The order starts
with the lowest digit from 0 to 9 and then the order goes by
letter.) In cases where unit # such as A101, A201, A901, A1001,
and B101 exist, the order starts with the lowest digit and goes in
the order A101, A201, A901, B101, A1001.
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either building number or
name.
Press
) or
ZOOM
WIDE
or hang
NOTES:
Building numbers and names are displayed in
alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
To end communication, press
up handset.
The guard station list is displayed.
- 36 -
GUARD STATION
Calling an entrance station
4-3
Press
).
Select the target entrance station.
Selected entrance station number and name
The search item list is displayed.
0001
ENTRANCE1
ZOOM
WIDE
ADJUS
WIDE
ZOOM
0001
0002
0003
0004
0005
ADJUST
ZOOM
Select "ENTRANCE" by pressing
WIDE
ZOOM
or
WIDE
Entrance station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
ENTRANCE
BUILDING
GUARD STATION
ENTRANCE
ZOOM
ADJUS
WIDE
1 / 1
ENTRANCE1
ENTRANCE2
ENTRANCE3
ENTRANCE4
ENTRANCE5
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either station number or name.
Press
ZOOM
) or
WIDE
),
or lift handset.
Communication starts and "
" is displayed.
* Audio guidance will be heard depending on the settings.
ZOOM
Select the target building by pressing
WIDE
or
ZOOM
WIDE
When the call is answered
The building list is displayed.
Press
To end communication, press
up handset.
or hang
Selected building number and name
01
CENTRAL TOWER
NOTE: Communication will end automatically after approximately
3 minutes.
ZOOM
1 / 1
CENTRAL TOWER
EAST TOWER
WEST TOWER
NORTH TOWER
SOUTH TOWER
ADJUS
WIDE
01
02
03
04
05
Building numbers and names are displayed in
alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either building number or
name.
Press
) or
ZOOM
WIDE
The entrance station list is displayed.
- 37 -
GUARD STATION
Direct calling an entrance station
(only when
Transferring video image taken by an
entrance station camera or surveillance
camera to a residential/tenant station
is displayed in standby
mode)
When
(only when
is displayed, press
mode)
).
The preset entrance station is called, and then communication is
enabled.
Talk hands-free or lift the handset.
To end communication, press
up handset.
is displayed in standby
Press
).
Select a residential/tenant station by one of
the following methods A - C .
or hang
A Press
ZOOM
) and then
WIDE
ZOOM
or
WIDE
to
select the target residential/tenant station.
B 1 Enter a number by using the 10-key to
display the list of residential/tenant
stations that include the number.
2 Press
ZOOM
ZOOM
or
WIDE
WIDE
to select the target
residential/tenant station.
3 Press
C 1 Press
) or
ZOOM
WIDE
and enter a letter by using the
10-key to display the list of residential/
tenant stations that include the letter.
2 Press
ZOOM
WIDE
ZOOM
or
WIDE
to select the target
residential/tenant station.
3 Press
) or
ZOOM
WIDE
Press
When the resident/tenant station answers and
).
accepts the visitor, press
handset.
* Step 2 differs depending on the settings.
- 38 -
or hang up
GUARD STATION
OPERATIONS DURING COMMUNICATION
5-1
Transferring a call
5-2
A call from an entrance station can be transferred to a residential/
tenant station via a guard station
Door release
While receiving a call or communicating with an
entrance station, press
After the guard station is called from an entrance
ZOOM
WIDE
station, press
the call.
ADJUST
or lift handset to answer
The number and name of
calling entrance station
Door release is activated at the entrance station.
1011
PARKING GATE
ZOOM
WIDE
* Audio guidance will be heard depending on the settings.
Press
( ) or enter the unit # by using [0] to
[9] on the 10-key.
NOTES:
• For an all-in-one type entrance station:
The door lock is released for the preset time. If the preset release
time is “0”, it can be released while the button is pressed and
held.
For a modular type entrance station:
If the VR1 dial (inside the cover) is set to “M (Momentary)”, it
can be released while the button is pressed and held.
• Depending on the electric door release system that you use, door
release may be active only while the door release button is pressed.
The list of residential/tenant stations is displayed.
Select the target residential/tenant station, then
press
).
The call is transferred to the residential/tenant station.
* "ON HOLD" is displayed on the entrance station and no
sound is heard at the entrance station.
CAUTION:
Be sure to confirm the visitor securely before releasing the door if the
entrance station has no camera.
When the residential/tenant station answers and
accepts the visitor, press
or hang up
handset to establish communication between the
entrance station and the residential/tenant
station.
* When there is no answer from the residential/tenant station,
hang up handset and pick it up again, or press
then
and
to communicate with the entrance station.
* Step 2 differs depending on the settings.
Reference:
Reception mode (→ 8-2 )
When there is a call from an entrance station to a residential/tenant
station, it is first transferred to the guard station, so a call tone sounds
and the video at the entrance station is displayed on the guard station.
- 39 -
GUARD STATION
5-3
Operating an optional
device
You can operate an optional device such as a light on this station.
Press
ZOOM
WIDE
ADJUST
The optional device turns on.
NOTES:
• A signal is sent to the device installed in the site. Please refer to
the specifications of the device.
• If no optional device is installed, nothing happens when the
button is pressed.
- 40 -
GUARD STATION
Viewing and adjusting video at an entrance station
5-4
You can view video at the target station when receiving a call from or
communicating with an entrance station with a camera, or monitoring
it. The video can be adjusted as desired by using the following
functions.
Pan & Tilt
ZOOM
ZOOM
When a zoom image is displayed, pressing
* These functions are not available for a door station.
WIDE
WIDE
ZOOM
WIDE
ZOOM
WIDE
, moves the image as shown below.
Switching Zoom/Wide
The display mode can be switched between zoom and wide by each
ZOOM
ZOOM
press of
WIDE
WIDE
ADJUST
ZOOM
WIDE
ADJUST
Wide
NOTES:
• At night, the object image may be blurred and less-visible when
moving the image from right to left or up and down because
illumination to the object is reduced. The same applies to a
moving object.
• The pan & tilt function is not available for a video door station
(JO-DV) .
Zoom
NOTES:
• The preset position of zoom image depends on the setting.
• When the display mode switches from wide to zoom, the zoom
image is displayed at the preset position.
• Depending on the properties of the camera, the wide image may
appear more distorted than the zoom image but this is not a
malfunction.
• The image range of the zoom mode and wide mode differs. The
edge of wide image will not be displayed with the zoom mode.
- 41 -
GUARD STATION
Adjusting screen view
If the video on the screen is difficult to see, you can adjust the screen
view.
Press
ADJUST
when the video is difficult to see.
ZOOM
WIDE
ADJUST
The backlight or night sensitivity is automatically adjusted.
* The discrimination between day and night is performed
automatically by this station.
* The adjustment result may vary depending on the setting.


[Before adjustment]
[Before adjustment]
[After adjustment]
[After adjustment]
To restore the screen view before adjustment
Press
ADJUST
again.
The icon is cleared and the screen view before adjustment is restored.
NOTES:
• Pressing
at night may make visitors' faces easier to see, but
may also make moving objects more difficult to see.
• The screen view adjusting function is not available for a video
door station (JO-DV).
ADJUST
- 42 -
GUARD STATION
MONITORING
You can monitor an entrance station or door station.
* When monitoring an entrance station or door station with a
camera, you can view the video at the station and hear the sound.
* The monitoring function is not available for an entrance station or
door station without a camera.
Press
The sound at the station is heard, and the video is displayed on the screen.
Selected station number and name
1011
PARKING GATE
Monitoring from a tenant building
* For monitoring a door station, start from step 5.
In standby mode, press
).
* While monitoring, you can switch zoom/wide, pan & tilt, and
adjust the screen view. (→ 5-4 )
ZOOM
ADJUST
WIDE
[To communicate with the station]
The search item list is displayed.
ZOOM
Select "ENTRANCE" by pressing
WIDE
WIDE
or lift handset.
Press
ZOOM
or
ENTRANCE
ZOOM
WIDE
ZOOM
ADJUS
WIDE
ADJUST
UNIT BY NUMBER
UNIT BY NAME
GUARD STATION
ENTRANCE
or
Communication with the station starts and "
Press
) or
ZOOM
WIDE
" is displayed.
* Until this step, the monitored stations cannot hear any sound
from the guard station.
The entrance station list is displayed.
Select the target entrance station by pressing
ZOOM
WIDE
To end monitoring or communication,
ZOOM
or
WIDE
Press
or hang up handset.
Selected entrance station number and name
0001
ENTRANCE1
NOTES:
• Monitoring ends automatically after about 30 seconds.
• Only entrance stations that can be selected by the guard station
can be monitored.
• When no door station is installed, pressing
has no
effect on the display.
ZOOM
ADJUST
WIDE
0001
0002
0003
0004
0005
1 / 1
ENTRANCE1
ENTRANCE2
ENTRANCE3
ENTRANCE4
ENTRANCE5
Entrance station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
ZOOM
ZOOM
WIDE
or
WIDE
to turn the page of the list.
* The list is displayed in order of either station number or name.
- 43 -
GUARD STATION
Monitoring from a main building
Select the target entrance station.
Selected entrance station number and name
* For monitoring a door station, start from step 7.
0001
ENTRANCE1
In standby mode, press
).
ZOOM
0001
0002
0003
0004
0005
Entrance station numbers and names are
displayed in alphabetical or numerical order.
* The arranging method differs depending on
the setting.
ZOOM
WIDE
ADJUST
ZOOM
Select "ENTRANCE" by pressing
WIDE
ZOOM
or
WIDE
* Press
BUILDING
GUARD STATION
ENTRANCE
ADJUS
WIDE
ZOOM
ZOOM
WIDE
or
to turn the page of the list.
WIDE
* The list is displayed in order of either station number or name.
ENTRANCE
ZOOM
1 / 1
ENTRANCE1
ENTRANCE2
ENTRANCE3
ENTRANCE4
ENTRANCE5
ADJUS
WIDE
The search item list is displayed.
Press
The sound at the station is heard, and the video is displayed on the screen.
Selected station number and name
1011
PARKING GATE
Press
ZOOM
) or
WIDE
The building list is displayed.
Select the target building.
Selected building number and name
* While monitoring, you can switch zoom/wide, pan & tilt, and
adjust the screen view. (→ 5-4 )
01
CENTRAL TOWER
ZOOM
1 / 1
CENTRAL TOWER
EAST TOWER
WEST TOWER
NORTH TOWER
SOUTH TOWER
ADJUS
WIDE
01
02
03
04
05
[To communicate with the station]
Press
or lift handset.
ZOOM
WIDE
ADJUST
or
Building numbers and names are displayed in
alphabetical or numerical order.
* The arranging method differs depending on
the setting.
* Press
Communication with the entrance station side starts and "
is displayed.
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* The list is displayed in order of either building number or
* Until this step, the monitored stations cannot hear any sound
name.
Press
from the guard station.
) or
ZOOM
WIDE
To end monitoring or communication,
The entrance station list is displayed.
Press
or hang up handset.
NOTES:
• Monitoring ends automatically after about 30 seconds.
• Only entrance stations that can be selected by the guard station
can be monitored.
• When no door station is installed, pressing
has no
effect on the display.
- 44 -
GUARD STATION
7-1
OTHER OPERATIONS
Checking for missed calls and calling back
If this station fails to respond to a call from a residential/tenant
station, "MISSED CALLS" flashes continuously on the display in
standby mode, and the status LED on the unit flashes. Check the
missed calls and call back if necessary.
To call back, select the target unit by pressing
ZOOM
WIDE
ZOOM
or
WIDE
Selected unit # and name
* On a guard station in a main section, the
building #, building name, and unit # of
the selected unit are displayed.
Flashes.
MISSED CALLS
102
AIPHONE
ZOOM
ZOOM
ADJUST
WIDE
101
102
103
201
202
NAME SEARCH
ZOOM
WIDE
EMERGENCY
1 / 1
SMITH
AIPHONE
DENTIST
LAINE
MENIN
NAME SEARCH
MISSED CALLS
* Press
Flashes.
ZOOM
ZOOM
or
WIDE
WIDE
to turn the page of the list.
* Depending on the settings, only the unit # may be displayed.
ZOOM
To check for missed calls, press
mode.
WIDE
in standby
A record of missed calls is displayed.
101
102
103
201
202
),
or lift handset.
Communication starts and "
ZOOM
ADJUST
When the call is answered
MISSED CALLS
101
SMITH
WIDE
Press
1 / 1
SMITH
AIPHONE
DENTIST
LAINE
MENIN
" is displayed.
To end communication,
press
or hang up handset.
NOTES:
• The guard station can hold up to 20 missed calls.
• A record of answered calls is not kept.
• While a record of missed calls are displayed, this station cannot
enter program mode.
When there are two or more missed calls, they
are listed in reverse chronological order.
* On a guard station in a main section, building
#, building names, and unit # are displayed.
- 45 -
GUARD STATION
7-2
Receiving an emergency call
When an emergency alarm switch is locked (or when a wire
disconnection occurs), an alarm sounds and an "EMERGENCY"
screen is displayed on this station. Check for the unit that sent the
emergency call, and take the necessary action.
EMERGENCY
101
SMITH
The unit # and name of
the unit that sent the
emergency call
* On a guard station in
a main section, the
building #, building
name, and unit # are
displayed.
To end communication, press
up handset.
or hang
To delete an emergency call from the list.
ZOOM
Select the target call by pressing
then press
ZOOM
or
WIDE
WIDE
).
EMERGENCY
101
SMITH
ZOOM
WIDE
To stop the alarm sound, press
ADJUST
101
201
).
1 / 1
SMITH
LAINE
EMERGENCY
101
SMITH
ZOOM
1 / 1
SMITH
101
ADJU
WIDE
NOTE: While a record of emergency calls are displayed, this
station cannot enter program mode.
The alarm stops and a record of emergency calls is displayed.
* On a guard station in a main section, building #, building
names, and unit # are displayed.
* When linked with multiple guard stations, stopping the alarm
on any guard station will stop the alarm of all the guard
stations.
To communicate with the unit, press
),
or lift handset.
EMERGENCY
101
SMITH
ZOOM
101
ADJU
WIDE
1 / 1
SMITH
* When there are two or more emergency calls, select one by
ZOOM
pressing
ZOOM
or
WIDE
WIDE
, then press
),
or lift handset.
* Press
ZOOM
ZOOM
WIDE
or
WIDE
to turn the page of the list.
* The list is displayed in chronological order.
When the call is answered
Communication starts and "
" is displayed.
- 46 -
GUARD STATION
To display a record of emergency calls
NAME SEARCH
EMERGENCY
ZOOM
WIDE
NAME SEARCH
MISSED CALLS
Flashes when there is one or more
unchecked emergency calls.
Press
ZOOM
WIDE
In standby mode.
A record of emergency calls is displayed.
To call a room that sent the emergency call
ZOOM
Select the target record by pressing
then press
),
WIDE
ZOOM
or
WIDE
, and
or lift handset.
NOTE: The emergency alarm keeps flashing until the target record
is deleted from the list. To delete it, select it on the list and
then press
).
The residential/tenant station keeps sounding the alarm until the
emergency alarm switch is restored at the room. In such case, the
record of emergency calls cannot be deleted with the guard
station. Unless the alarm is restored at the room, no call can be
made from the guard station to the room.
Please make sure the alarm is restored at the room.
NOTES:
• If an emergency call is already active on this station and this
station is in communication, another guard station cannot
interrupt. (An in-use tone will be heard from handset or speaker
of the guard station.)
• The emergency alarm is given priority even when the system is
in use. (Alarms can be activated at the same time for up to 5
units. This excludes GT-2C-L and GT-2C.)
• Emergency calls can be made while the system is in use.
• With the GT-2C-L and GT-2C, it is possible to transfer to a guard
station even when there is a security alarm, depending on the
settings.
• Even when the call tone volume is set to mute on the guard
station, an alarm goes off at the maximum volume.
- 47 -
GUARD STATION
SETTING
8-1
Adjusting display brightness and volumes
Adjusting brightness of the display
Adjusting the call tone volume
You can adjust the call tone volume at this station.
In standby mode, press
In standby mode, press
The SETTINGS screen is displayed.
ZOOM
WIDE
ADJUST
ZOOM
Select "TONE VOLUME" by pressing
WIDE
or
ZOOM
WIDE
The SETTINGS screen is displayed.
SETTINGS
ZOOM
Select "BRIGHTNESS" by pressing
ZOOM
or
WIDE
WIDE
BRIGHTNESS
TONE VOLUME
ZOOM
SETTINGS
WIDE
ADJUS
RECEIVE VOLUME
BRIGHTNESS
ADVANCED SETTINGS
TONE VOLUME
ZOOM
WIDE
ADJUS
RECEIVE VOLUME
ADVANCED SETTINGS
WIDE
or
WIDE
WIDE
ADJUS
or
WIDE
BRIGHTNESS
TONE VOLUME
ZOOM
SETTINGS
ZOOM
WIDE
SETTINGS
ZOOM
ZOOM
Adjust the brightness by pressing
ZOOM
ZOOM
Adjust the volume by pressing
WIDE
ADJUS
BRIGHTNESS
RECEIVE VOLUME
TONE VOLUME
ADVANCED SETTINGS
RECEIVE VOLUME
ADVANCED SETTINGS
Adjustment can be made in 4 levels.
("Mute" is available.)
* If set to "mute”, the status LED will flash with
long intervals. (→ 1-2 )
Adjustment can be made in 10 levels.
To return to the previous screen
Press
To return to the previous screen
).
Press
To adjust brightness of the display while
being called or in communication
Press
Adjust the brightness by pressing
While being called or in communication,
press
).
ZOOM
ZOOM
WIDE
or
).
To adjust the call tone volume while being
called or in communication
While being called or in communication,
press
WIDE
- 48 -
Press
Adjust the volume by pressing
ZOOM
ZOOM
WIDE
or
WIDE
GUARD STATION
Adjusting the receive volume
You can adjust the speaker volume of this station.
In standby mode, press
The SETTINGS screen is displayed.
ZOOM
Select "RECEIVE VOLUME" by pressing
or
WIDE
ZOOM
WIDE
SETTINGS
BRIGHTNESS
TONE VOLUME
ZOOM
WIDE
ADJUS
RECEIVE VOLUME
ADVANCED SETTINGS
ZOOM
ZOOM
Adjust the volume by pressing
WIDE
or
WIDE
SETTINGS
BRIGHTNESS
TONE VOLUME
ZOOM
WIDE
ADJUS
RECEIVE VOLUME
ADVANCED SETTINGS
Adjustment can be made in 3 levels.
To return to the previous screen
Press
).
To adjust the receive volume while being
called or in communication
While being called or in communication,
press
Press
Adjust the volume by pressing
).
ZOOM
ZOOM
WIDE
or
WIDE
- 49 -
GUARD STATION
8-2
Switching to reception mode
* This section describes the reception mode and how to configure it.
Refer to steps 2 to 3 of " 5-1 Transferring a call" for the
Switching this station between normal mode
and reception mode
operating procedure.
What is reception mode?
In standby mode, press
The SETTINGS screen is displayed.
In reception mode, all of the calls from entrance stations to
residential/tenant stations are first transferred to guard stations.
You can transfer the calls to residential/tenant stations after
confirming they are not unwanted calls to the target residents.
Select "ADVANCED SETTINGS"
ZOOM
by pressing
WIDE
ZOOM
or
[Normal mode]
WIDE
SETTINGS
BRIGHTNESS
Call
TONE VOLUME
ZOOM
WIDE
ADJUS
RECEIVE VOLUME
ADVANCED SETTINGS
Residential/tenant
station
Entrance station
Guard station (this station)
Select "RECEPTION MODE"
ZOOM
by pressing
WIDE
ZOOM
or
WIDE
ADVANCED SETTINGS
[Reception mode]
RECEPTION MODE
OFF
ZOOM
WIDE
Call
Entrance station
ADJUS
PROGRAM MODE
Transfer
Residential/tenant
station
Guard station (this station)
Press
ZOOM
) or
WIDE
Change reception mode to "ON" or "OFF" by
ZOOM
ZOOM
pressing
WIDE
or
WIDE
ADVANCED SETTINGS
NOTES:
• In a main building:
Calls from an entrance station are transferred to all guard stations
in the building. The call tone sounds on all guard stations at the
same time.
In a tenant building:
Calls from an entrance station are transferred to all guard stations
in the tenant building that are linked to the corresponding
residential/tenant station. The call tone sounds on all guard
stations at the same time.
• A call to a residential/tenant station that is not linked to a guard
station will result in a call to the residential/tenant station
directly.
RECEPTION MODE
OFF
ZOOM
WIDE
ADJUS
PROGRAM MODE
ON: Reception mode is active.
OFF: Normal mode is active.
Press
) or
ZOOM
WIDE
* When this station is in reception mode, the status LED will
flash slowly. (→ 1-2 )
To return to the previous screen
Press
- 50 -
).
GUARD STATION
Switching to program mode
8-3
* This operation is for Administrators and Managers only
Entering a passcord is needed to switch this station into program
mode. Ask the system installer for the passcord.
* A registered NFC-compliant IC card can be used instead of a
passcord.
In standby mode, press
(or pass an
registered NFC-compliant IC card over the NFC
reader).
The SETTINGS screen is displayed.
Select "ADVANCED SETTINGS"
ZOOM
by pressing
WIDE
ZOOM
or
WIDE
SETTINGS
BRIGHTNESS
TONE VOLUME
ZOOM
WIDE
ADJUS
RECEIVE VOLUME
ADVANCED SETTINGS
Select "PROGRAM MODE"
ZOOM
by pressing
WIDE
ZOOM
or
WIDE
ADVANCED SETTINGS
RECEPTION MODE
OFF
ZOOM
WIDE
Press
ADJUS
PROGRAM MODE
) or
ZOOM
WIDE
The passcord entry screen is displayed.
Enter the passcord.
* Refer to the GT SYSTEM SETTING MANUAL/Standard &
Expanded System for details about the settings.
NOTE: An NFC card can be used with either "Admin" or
"Manager" authority. (→ GT SYSTEM SETTING
MANUAL/Standard & Expanded System)
- 51 -
GUARD STATION
UPDATING RESIDENT INFORMATION
Refer to the GT SYSTEM/SETTING MANUAL.
• For single building system (→ GT SYSTEM SETTING
MANUAL/Standard & Expanded System)
• For multi building system (→ GT SYSTEM SETTING
MANUAL/Multi Building System)
When using an Android device
(→ GT SYSTEM SETTING MANUAL/Aiphone GT Setup Tool
for Android)
Android is a trademark of Google Inc. in the United States and/or
other countries.
- 52 -
FOR PROPER USE OF THIS STATION
TECHNICAL PRECAUTIONS
• Cleaning:
Clean the units with a soft cloth dampened with a neutral
household cleanser. Do not use any abrasive cleaner or cloth.
CAUTION: Do not use chemicals such as thinner or benzine. In
addition, do not use a scrub brush, sandpaper, etc. Otherwise the
unit surface could be damaged or discolored.
[For guard station only]
• The video image may distort when door release is activated. This
is not a station malfunction.
• If a zoom/wide, pan/tilt, door release operation or brightness
adjustment is performed during communication with the entrance
station, noise will be produced at the entrance station. This is not a
malfunction.
[General]
• If there is a system malfunction, contact a qualified technician for
service.
- 53 -
FOR PROPER USE OF THIS STATION
SPECIFICATIONS
1-call button panel (GF-1P)/2-call button panel (GF-2P)/
3-call button panel (GF-3P)/4-call button panel (GF-4P)
Entrance station (modular type)
Camera module (GT-VB)
Power source
Ambient temperature
Material
Dimensions
Mass
Material
Supplied from GT-VBC
- 10°C - +60°C (+14°F - +140°F)
Self-extinguishing PC+ABS resin
108 (W) x 93 (H) x 55 (D) mm
4-1/4" (W) x 3-11/16" (H) x 2-3/16" (D)
Approx. 130g (0.29 lbs.)
Color
Dimensions
Mass
Camera module panel (GT-VP)
Material
Color
Dimensions
Mass
Zinc die cast
Metallic beige
110 (W) x 95 (H) x 8 (D) mm
4-5/16" (W) x 3-3/4" (H) x 5/16" (D)
Approx. 150g (0.34 lbs.)
10-key module panel (GF-10KP)
Material
Color
Audio module (GT-DB/GT-DB-V/GT-DB-VN)
Dimensions
Power source
Ambient temperature
Material
Mass
Dimensions
Mass
Supplied from GT-BC
- 10°C - +60°C (+14°F - +140°F)
Self-extinguishing ABS resin
108 (W) x 93 (H) x 53.4 (D) mm
4-1/4" (W) x 3-11/16" (H) x 2-1/8" (D)
GT-DB, GT-DB-V: Approx. 210g (0.47 lbs)
GT-DB-VN: Approx. 220g (0.49 lbs)
Dimensions
Mass
Power source
Ambient temperature
Material
Dimensions
Mass
Zinc die cast
Metallic beige
109.7 (W) x 94.9 (H) x 7.9 (D) mm
4-5/16" (W) x 3-3/4" (H) x 5/16" (D)
Approx. 95g (0.21 lbs)
Ambient temperature
Material
Dimensions
Mass
Material
Color
Dimensions
DC 24V supplied from a power supply unit
(PS-2420 etc.)
- 10°C - +60°C (+14°F - +140°F)
Self-extinguishing ABS resin
104.6 (W) x 88.3 (H) x 49.1 (D) mm
4-1/8" (W) x 3-1/2" (H) x 1-15/16" (D)
Approx. 140g (0.31 lbs)
Mass
Color
Dimensions
Mass
Material
Color
Dimensions
Mass
Panel: Zinc die cast
Window: Polycarbonate
Bottom: Chrome plated zinc die cast
Metallic beige
110 (W) x 96 (H) x 31.2 (D) mm
4-5/16" (W) x 3-3/4" (H) x 1-3/4" (D)
Approx. 200g (0.49 lbs.)
Dimensions
Mass
Zinc die cast
Metallic beige
110 (W) x 95.2 (H) x 14.3 (D) mm
4-5/16" (W) x 3-3/4" (H) x 9/16" (D)
Approx. 190g (0.42 lbs.)
4-module front frame (GF-4F)/3-module front frame
(GF-3F)/2-module front frame (GF-2F)
Material
Color
Call switch module (GT-SW)
Power source
Ambient temperature
Material
Panel: Zinc die cast
Window: Polycarbonate
Metallic beige
110 (W) x 95.2 (H) x 14.3 (D) mm
4-5/16" (W) x 3-3/4" (H) x 9/16" (D)
Approx. 150g (0.34 lbs.)
Blank panel (GF-BP)
Name scrolling module panel (GT-NSP-L)
Material
Supplied from GT-DB/GT-DB-V/GT-DB-VN
- 10°C - +60°C (+14°F - +140°F)
Self-extinguishing ABS plastic
105.6 (W) x 88.3 (H) x 42.5 (D) mm
4-3/16" (W) x 3-1/2" (H) x1-11/16" (D)
Approx. 90g (0.199 lbs.)
Address module panel (GF-AP)
Name scrolling module (GT-NSB)
Power source
Panel: Zinc die cast
Box: Chrome plated steel
Metallic beige
110 (W) x 96.1 (H) x 38.2 (D) mm
4-5/16" (W) x 3-13/16" (H) x 15/16" (D)
Approx. 310g (0.69 lbs.)
Address module (GF-AD)
Audio panel (GT-DBP)
Material
Color
Panel: Zinc die cast
Window: Polycarbonate
Bottom: Chrome plated zinc die cast
Metallic beige
110 (W) x 95.2 (H) x 15.8 (D) mm
4-5/16" (W) x 3-3/4" (H) x 5/8" (D)
GF-1P: Approx. 180g (0.40 lbs.)
GF-2P: Approx. 190g (0.42 lbs.)
GF-3P: Approx. 190g (0.42 lbs.)
GF-4P: Approx. 200g (0.45 lbs.)
Supplied from GT-DB/GT-DB-V/GT-DB-VN
- 10°C - +60°C (+14°F - +140°F)
Self-extinguishing ABS plastic
90.5 (W) x 106 (H) x 42.5 (D) mm
3-9/16" (W) x 4-3/16" (H) x 1-11/16" (D)
Approx. 90g (0.199 lbs.)
Dimensions
Mass
- 54 -
Front frame: Zinc die cast
Mounting bracket: Stainless steel
Metallic beige
GF-2F: 135 (W) x 225 (H) x 16 (D) mm
5-5/16" (W) x 8-7/8" (H) x 5/8" (D)
GF-3F: 135 (W) x 320 (H) x 16 (D) mm
5-5/16" (W) x 12-5/8" (H) x 5/8" (D)
GF-4F: 135 (W) x 425 (H) x 16 (D) mm
5-5/16" (W) x 16-3/4" (H) x 5/8" (D)
GF-2F:
Front frame: Approx. 400g (0.89 lbs.)
Mounting bracket: Approx. 200g (0.45 lbs.)
GF-3F:
Front frame: Approx. 490g (1.09 lbs.)
Mounting bracket: Approx. 250g (0.56 lbs.)
GF-4F:
Front frame: Approx. 660g (1.46 lbs.)
Mounting bracket: Approx. 290g (0.64 lbs.)
FOR PROPER USE OF THIS STATION
Entrance station (all-in-one type)
All-in-one entrance station (GT-DMB-N/GT-DMB-LVN)
DC 24V supplied from a power supply unit (PS-2420
etc.)
Ambient temperature - 10°C - +60°C (+14°F - +140°F)
Panel: Stainless steel
Material
Case: Self-extinguishing ABS resin
Panel: Stainless steel with hairline finishing
Color
Case: Black
GT-DMB-N: 150 (W) x 320 (H) x 38.5 (D) mm
5-7/8" (W) x 12-5/8" (H) x 1-1/2" (D)
Dimensions
GT-DMB-LVN: 150 (W) x 425 (H) x 38.5 (D) mm
5-7/8" (W) x 16-3/4" (H) x 1-1/2" (D)
GT-DMB-N: Approx. 1,200g (2.70 lbs)
Mass
GT-DMB-LVN: Approx. 1,500g (3.3 lbs)
Power source
Guard station
Guard station (GT-MKB-N)
Power source
Communication
Ambient temperature
Monitor
Mounting
Material
Color
Dimensions
Mass
DC 24V supplied from a power supply unit
(PS-2420 etc.)
Open voice: Voice-actuated
Handset: Voice-actuated/Full-duplex (only when
the other side is talking using the handset of
GT-MKB-N or GT-1D)
0 - 40°C (+32°F - +104°F)
3.5 inch TFT color LCD
Desktop use (with desktop stand) or surface
wall-mount
Self-extinguishing ABS resin
Black
250 (W) x 189 (H) x 59 (D) mm
9-13/16" (W) x 7-7/16" (H) x 2-5/16" (D)
Approx. 820g (1.81 lbs)
When used with desk stand:
Approx. 1,200g (2.70 lbs)
Door station
Vandal-resistant video door station (surface-mount)
(JO-DV)
Power source
Communication
Ambient temperature
Material
Color
Dimensions
Mass
Remarks
Supplied from guard station
Open voice hands-free communication
- 20°C - +60°C (- 4°F - +140°F)
Front panel: Zinc die cast
Main unit: Self-extinguishing
Front panel: Silver
98 (W) x 173 (H) x 27 (D) mm
3-7/8" (W) x 6-13/16" (H) x 1-1/16" (D)
Approx. 650g (1.44 lbs.)
IP54, IK08
- 55 -
FOR PROPER USE OF THIS STATION
SOFTWARE LICENSE
Notice regarding software
Use of the software installed on this product has received direct or indirect authorization from third parties.
(1) GPL/LGPL
This product includes software components subject to the GPL/LGPL.
Customers can obtain, modify, and re-distribute the source code of the software components according to the GPL/LGPL.
Hereafter referred to as the link
Open source code
This product includes software components subject to the GPL/LGPL, and customers can obtain, modify, and re-distribute the
source code of the software components according to the GPL/LGPL. In addition, you can find details on the GPL/LGPL through the
following links.
http://www.gnu.org/licenses/gpl.html
http://www.gnu.org/licenses/lgpl.html
Please confirm the following contents when downloading.
<>
■ According to GPL/LGPL, the source code of the software components is not guaranteed, including warranty on
“merchantability” or “suitability for a particular purpose.”
■ The source code of the software components are according to the “status quo,” and are provided based on the GPL/LGPL.
■ Please understand that we cannot answer questions regarding the content of the source code of the software components.
BSD License
Copyright (c) 2017, AIPHONE CO.,LTD
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER
IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF
THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
The views and conclusions contained in the software and documentation are those of the authors and should not be interpreted as
representing official policies, either expressed or implied, of the FreeBSD Project.
- 56 -
FOR PROPER USE OF THIS STATION
REGULATIONS
FCC
RED
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
Hereby, Aiphone Co., Ltd. declares that the radio equipment type
[GT-DB-VN, GT-DMB-N, GT-DMB-LVN, GT-MKB-N, GTBCXB-N] is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address:
http://www.aiphone.net/
GT-MKB-N: 13.56MHz / Max. 20.0 dBm
GT-DMB-N: 13.56MHz / Max. 20.0 dBm
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
GT-DMB-LVN: 13.56MHz / Max. 20.0 dBm
GT-DB-VN: 13.56MHz / Max. 20.0 dBm
GT-BCXB-N: 13.56MHz / Max. 20.0 dBm
NCC
電信法第48條
低功率電波輻射性電機管理辦法
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或
使用者均不得擅自變更頻率、加大功率或變更原設計之特性及
功能。
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經
INDUSTRY CANADA
發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續
CAN ICES-3 (B)/NMB-3(B)
使用。
This device complies with Industry Canada's licence-exempt
RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and (2) This
device must accept any interference, including interference
that may cause undesired operation of the device.
前項合法通信,指依電信法規定作業之無線電通信。
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻
射性電機設備之干擾。
WEEE
The object area of
- 57 -
is the EU.
FOR PROPER USE OF THIS STATION
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of 2
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon
which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final
decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This
warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in
violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty
does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only,
and any repairs must be made at the shop or place designated in writing by Aiphone. This warranty is limited to the standard
specifications listed in the operation manual. This warranty does not cover any supplementary function of a third party product that
is added by users or suppliers. Please note that any damage or other issues caused by failure of function or interconnection with
Aiphone products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site
service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its
products during use, or for any consequent inconvenience or losses that may result.
http://www.aiphone.net/
Issue Date: Jun. 2017
B P0617 SZ 59038
- 58 -
AIPHONE CO., LTD., NAGOYA, JAPAN

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : UENO
Create Date                     : 2017:05:29 19:51:24+09:00
Modify Date                     : 2017:06:05 20:11:10+09:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 17.0 (Windows)
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Metadata Date                   : 2017:06:05 20:11:10+09:00
Format                          : application/pdf
Title                           : ENG_GT-DMB_MKB_17.05.29.indd
Creator                         : UENO
Document ID                     : uuid:bdb8040d-2735-4242-9237-ab714577079e
Instance ID                     : uuid:8e186615-f2d2-46b1-955f-a26ad3208e50
Page Layout                     : SinglePage
Page Count                      : 58
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALNEGTDMBN

Navigation menu