AISOLUTION KDCUHF10 KDCSLED UHF 1.0W RFID Module User Manual

AISOLUTION CO., LTD. KDCSLED UHF 1.0W RFID Module

User manual

       KDCSLED-UHF 1.0W User Guide
1  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com Table of Contents Table of Contents .................................................................................................................................................. 1 1. KDCSLED-UHF1.0W ...................................................................................................................................... 2 2. KDCSLED-UHF1.0W Operation ..................................................................................................................... 3 2.1 Remove and insert battery .................................................................................................................... 3 2.2 Trigger .................................................................................................................................................. 4 2.3 How to use KDCSLED-UHF1.0W ........................................................................................................... 5 3. KDCSLED-UHF1.0W Configuration ................................................................................................................ 5 3.1 Read Mode (Barcode-reading mode vs. Tag-reading mode) .......................................................................... 5 3.2 Operation Mode (Single-reading mode vs. Multiple-reading mode) .............................................................. 6 3.3 Triggering Methods ...................................................................................................................................... 6 3.4 Timeout Value .............................................................................................................................................. 6 3.5 Data Types.................................................................................................................................................... 6 3.6 Data Format ................................................................................................................................................. 7 4. KDCSLED-UHF1.0W Special Barcodes ........................................................................................................... 7
2  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com 1. KDCSLED-UHF1.0W KDCSLED-UHF1.0W enables user to read UHF tag within mid/long range with pistol grip.  ➢ Product Specification KDCSLED-UHF1.0W is fully compliant with ISO18000-6C/EPC Global Gen II reader protocol Specification  KDCSLED-UHF1.0W UHF Standards Supported EPC Class1 Gen2, EPC Gen2 V2, ISO 18000-6c Antenna type/field  4dbi Compact Air Substrate Polarized Antenna Tx Output Power Range  +10 to +30 dBm  (+30dBm maximum in Japan) Spectrum Range  902Mhz – 927Mhz  Support Region  US, Europe, Korea, Japan Rx Sensitivity  < -85 dBm Fastest read rate  Up to 800 Tags per second Nominal read range  6 meters Batch mode memory  409,600 RFID tags (EPC Data) Physical Dimensions  80.9 x 116.95 x 114.95 (mm) W/ KDCSLED: 80.9 x 116.95 x 123.95 (mm) Weight  TBD TBD Reliability Drop spec  4 feet (1.2m) Temp spec  Operating: -4˚F (-20˚C) ~ 122˚F (50˚C) Storage: -4˚F (-20˚C) ~ 140˚F (59˚C) Humidity spec  5% ~ 94% (noncondensing) Sealing  IP65 Certification  Compliance  CE,FCC,KC
3  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com 2. KDCSLED-UHF1.0W Operation  2.1 Remove and insert battery ➢ Open battery cover as below picture.  ➢ Remove and insert battery into battery room as below picture.
4  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com ➢ Close battery cover as below picture.  2.2 Trigger  ➢ The trigger of UHF 1.0W pistol grip used to scan barcode or read RFID tag.
5  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com 2.3 How to use KDCSLED-UHF1.0W  ➢ It is recommended to use KDCSLED-UHF1.0W as below picture to read RFID tag.   ➢ For optimal UHF tag read performance and to be sure that human exposure to RF energy does not exceed the FCC, European Union guidelines, always follow below instructions and precautions: o Before using KDCSLED-UHF1.0W reader, user should carefully read this manual to understand how to use KDCSLED-UHF1.0W reader properly. o KDCSLED-UHF1.0W reader should be used by professional person who understand fully how to operate KDCSLED-UHF1.0W reader. o Maintain at least 20cm between KDCSLED-UHF1.0W reader and the body when reading UHF RFID tag. o Keep KDCSLED-UHF1.0W Antenna to face the UHF RFID tag, but not your body when reading UHF RFID tag. o Exit UHF tag read mode and keep Barcode read mode when finished reading UHF tag. o Don’t wear KDCSLED-UHF1.0W reader when not using KDCSLED-UHF1.0W reader.  3. KDCSLED-UHF1.0W Configuration  3.1 Read Mode (Barcode-reading mode vs. Tag-reading mode) ➢ There are two read modes. One is barcode-reading mode (Barcode can be read by SCAN button) and the other one is tag-reading mode (UHF Tag can be read by SCAN button). ➢ After reset, KDC470 is set to a barcode-reading mode. ➢ The mode can be changed when you press and hold UP button for 3 seconds.  ➢ Or, the application can also change the mode between a barcode-reading mode and a tag-reading mode using SDK. ➢ When the mode is changed, 3 short beeps means a tag-reading mode. 1 long and 1 short beeps means a barcode-reading mode.
6  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com 3.2 Operation Mode (Single-reading mode vs. Multiple-reading mode) ➢ KDC470 has two operation modes: Single-reading and Multiple-reading. ➢ Single-reading mode means it reads only one tag by triggering the SCAN button once. ➢ Multiple-reading mode means it reads multiple tags by triggering the SCAN button once. ➢ The mode can be changed by scanning the special barcodes below. (The default is a Multiple-reading mode). Single-reading Mode  Multiple-reading Mode   ➢ In the single-reading mode, it keeps trying to read any tag until timeout value is expired. Once it reads any tag, KDC470 sends the first read tag information to the host and stops reading. ➢ In the multiple-reading mode, KDC470 sends all the information of the tags which are read until timeout value is expired. ➢ The application can also change the mode between a single-reading mode and a multiple-reading mode using SDK.  3.3 Triggering Methods ➢ There are two ways to read a UHF tag: Hardware-triggering and software-triggering. ➢ The hardware-triggering is done by a SCAN button and the software-triggering is done by an API called from an application using SDK.  3.4 Timeout Value ➢ KDC470 has UHF tag reading timeout value with the same with Barcode reading timeout value. The default timeout is a 2 second.   3.5 Data Types ➢ KDC470 only sends EPC data to a host by default but sends along with PC data if the user configures PC+EPC by reading the special barcode below.  Data Type – EPC  Data Type - PC+EPC   ➢ The data types can also be changed using SDK.
7  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com  3.6 Data Format ➢ KDC470 sends tag data to a host with binary format by default and can be changed to HexaDecimal format by reading the special barcode below.  Data Format = Binary  Data Format = Hexa Decimal   ➢ The data format can also be changed using SDK. 4. KDCSLED-UHF1.0W Special Barcodes   Enable UHF Power   Disable UHF Power   Power Level = 18dBm  Power Level = 19dBm  Power Level = 20dBm  Power Level = 21dBm  Power Level = 22dBm  Power Level = 23dBm
8  KOAMTAC, Inc. | 116 Village Blvd. Suite 305 | Princeton, NJ 08540 | phone 609.256.4700 | fax 609.228.4373 www.koamtac.com Power Level = 24dBm  Power Level = 25dBm  Power Level = 26dBm  Power Level = 27dBm  Power Level = 28dBm  Power Level = 29dBm  Power Level = 30dBm   Data Format = Binary  Data Format = Hexa Decimal
FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE:   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  SAR Information Statement Your RFID Module is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radiofrequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for RFID Module employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 4.0 W/kg. * Tests for SAR are conducted with the RFID Module transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the RFID Module while operating can be well below the maximum value. This is because the RFID Module is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a RFID Module model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The maximum scaled SAR in extremity mode is 0.582W/Kg. While there may be differences between the SAR levels of various RFID Module and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model RFID Module with all reported SAR levels evaluated as in compliance with the FCC RFexposure guidelines. SAR information on this model RFID Module is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/ oet/fccid after searching on   FCC ID:VH9-KDCUHF10 Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Asso-ciation (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile RFID Module used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a sub-stantial margin of safety to give additional protection for the public and to account for any variations in measurements.  Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance  of 25mm  must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters,   and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved

Navigation menu