ALE USA Inc. OmniAccess Stellar AP1220 series

User manual

Download: ALE USA OAW-AP122X OmniAccess Stellar AP1220 series User Manual
Mirror Download [FCC.gov]ALE USA OAW-AP122X OmniAccess Stellar AP1220 series User Manual
Document ID3550058
Application IDgT/dDuTuUbwg1ekF58tCjg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize43.32kB (541546 bits)
Date Submitted2017-09-07 00:00:00
Date Available2018-03-07 00:00:00
Creation Date2017-07-06 10:42:23
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2017-07-06 10:43:18
Document TitleOmniAccess Stellar AP1220 Series Installation Guide (060455-10 Rev. B)
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: Alcatel-Lucent Enterprise

Alcatel-Lucent Enterprise
OmniAccess Stellar AP1220 Series
Installation Guide
Summary of installation Steps
060455-10 Rev. B
•
•
•
•
•
•
•
*060455-10 Rev. B*
•
•
WLAN Planning. Usually, a comprehensive site survey is required
before installation, such as installation location, brackets, cables,
power source, etc.
Unpack the AP box and check all contents
Install the AP bracket on ceiling or wall
Installing the AP
Connecting required cables
Power connection
Verifying post-installation connectivity
AP provisioning
Hidden LED Location
Package Contents
Item
Name
Access Point
Quick Start Guide
Installation Guide
Regulatory Compliance and Safety
Information
User Guide Info Card
Mounting Bracket (15/16”)
Mounting Bracket (9/16”)
Identifying Specific Installation Locations
You can mount the OmniAccess Stellar AP on a ceiling rail (using the
shipped bracket in the box) or on a wall (using the wall mount adapter,
sold separately). You should first determine the location of the
installation. The installation position is located at the center of the
required coverage area and should be free from obstructions or
obvious sources of interference.
•
•
AP is a radio transmission device and subject to governmental regulation.
Network administrators must comply with local regulations.
A terminal or a notebook
Minimize the number of obstructions (such as walls) between the AP
and user terminals.
Electronic equipment or devices (such as microwave ovens) which
may produce radio frequency noise should be away from the
installation position of the AP.
It is strictly prohibited to install around stagnant water, water seepage,
leakage or condensation. Avoid cable condensation or water seepage
along the cables connecting to the AP.
Qty
Unit
Pcs
Pcs
Pcs
Pcs
Temperature and Humidity requirement
Pcs
Pcs
Pcs
•
•
•
Figure 2: AP Front View
Operating temperature: 32ºF to 113ºF(0ºC to 45ºC )
Storage temperature: -40ºF to 158ºF(-40ºC to 70ºC)
Relative Humidity: 10% to 90% non-condensing
AP Installation
Using Ceiling Mounting Bracket
Make sure the AP fits securely on the ceiling tile rail when
hanging the device from the ceiling, poor installation could cause
it to fall onto people or equipment.
Security
Figure1: AP Packing
Inform your ALE sales representative of incorrect, missing, or
damaged parts. If possible, retain the carton, including the
original packing materials. Use these materials to repack and
return the unit to the supplier if needed. Additional mounting
kits for use with the OmniAccess Stellar AP1220 series access
points are sold separately. Contact your ALE sales representative
for details.
Unpack OAW-AP1221 or AP1222 box:
•
AP Dimensions: 180mm (W) x 180mm (D) x 36mm (H) -7.08”
(W) x 7.08” (D) x 1.41” (H)
•
Net Weight:
700g / 1.54lb(OAW-AP1221)
720g / 1.59lb(OAW-AP1222)
USB
enterprise.alcatel-lucent.com
Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view
other trademarks used by affiliated companies of ALE holding, visit:
enterprise.alcatel-lucent.com/trademarks. All other trademarks are the property of their
respective owners. The information presented is subject to ALE without notice. Neither ALE
Holding nor any of its affiliates assumes any responsibility for inaccuracies contained herein.
(2017)
Ethernet
Console
DC Power Socket
Figure 3: AP Back View
Interface
Ethernet
Console
USB
DC Power
Socket
Kensington
Lock Slot
Reset
OAW-AP1221 View
The OmniAccess Stellar AP1220 Series APs are mid-end 802.11ac wave2
APs for medium density and large business deployments. AP1220 Series
APs provide high throughput and seamless user experience.
Reset
Specifications
1× 10/100/1000BASE-T autosensing (RJ-45) port, Power
over Ethernet (PoE).
1× Management Console Port (RJ-45).
Note: Currently for use by Service & Support only.
1× USB 2.0 (Type A connector)
DC 48V power socket. Optional AC-DC adapter kit (sold
separately) could be used to power the AP.
The OmniAccess Stellar AP has been shipped with two mounting brackets
for 9/16” and 15/16” ceiling rails. Following is the general sequence to
install the AP with the mounting bracket.
•
Pull the cables through a prepared hole in the ceiling tile near
where the AP will be placed.
•
Place the bracket against the back of the AP, insert by aligning the
slot on the backside with the hanging feet on both sides of the
bracket (see Figure 4).
•
Push the bracket along the direction of the arrow until it locks in
the slot (see Figure 4).
•
Connect the cable to the port on the AP.
•
Hold the AP next to the ceiling tile rail with the ceiling tile rail
mounting slots at approximately a 20-degree angle to the ceiling
tile rail (see Figure 5). Make sure that any cable slack is above the
ceiling tile.
•
Pushing toward the ceiling tile, rotate the AP clockwise until the
device clicks into place on the ceiling tile rail (see Figure 5).
A Kensington security slot for additional security.
Factory reset. Press reset button for 5s, AP LEDs will
quickly flashing for 3s, then AP will restart and restore
factory configurations.
Table 1: External Interfaces
Pre-Installation
Pre-Installation Checklist
Before installing AP, be sure that you have the following items:
•
4- or 8-conductor, CAT5 or better UTP cable of required length.
•
One of the following power sources:

IEEE 802.3at compliant Power over Ethernet (PoE) source
(The PoE source can be any power source equipment (PSE)
controller or mid-span PSE device).

AC-DC adapter (sold separately),output voltage DC 48V,
output current > 0.4A
Figure 4: Attaching Ceiling Mounting Bracket
ON
Figure 5: Mounting AP
Pin
Signal
Name
GE
ON
System running
Flash
Flash
System running
Flash
Flash
Flash
System running
Network normal, single
band working,
either 2.4Ghz or 5Ghz
Network normal, dual
bands working, 2.4Ghz
and 5Ghz are both
working
Red and Blue LEDs
alternate flashing
in specific frequency;
OS upgrading
3 LEDs alternate flashing in specific
frequency; Used for
locating an AP
FE
PoE
RJ45_DA+
BI_DA+
RX+
PoE-
RJ45_DA–
BI_DA-
RX–
PoE-
RJ45_DB+
BI_DB+
TX+
PoE+
RJ45_DC+
BI_DC+
Spare
PoE+
RJ45_DC–
BI_DC-
Spare
PoE+
Console Port
The serial console port allows you to connect the AP to a serial terminal
or a laptop for direct local management. This port is an RJ-45 female
connector with the pinouts described in Table 4.
Note: Currently for use by Service & Support only.
Connector
BI_DA6
RJ45_DB–
BI_DB-
TX–
PoE+
RJ45_DD+
BI_DD+
Spare
PoE-
RJ45_DD–
BI_DD-
Spare
PoE-
Pin
Signal Name
Function
TXD
Transmit
GND
Ground
GND
Ground
RXD
Receive
Pins not listed are not connected.
Table 4: Console Port Pinout
Configuring the OmniAccess Stellar AP
Refer to the Quick Start Guide and Configuration Guide for complete
details.
OAW-AP1222 View
Connect Power Sources
Confirm that you have an IEEE 802.3at compliant Power over Ethernet
(PoE) source on the Ethernet cable, if not, connect by using the ALE 48V
AC-DC adapter kit (sold separately) to the DC Power Socket and AC power
jack.
If both PoE and DC power are available, the use of DC is preferred.
OmniAccess Stellar AP supports the power adapter provided by
ALE ONLY.
Verifying Post-Installation Connectivity
The LED on the AP can be used at this point to verify that the AP is
receiving power and initializing successfully (see Table 3).
Blue
Green
Time
Line
ON
Power on
ON
Bootloader-OS
loading
Flash
System running
Flash
System running
The external antenna is sold separately.
Hidden LED Location
Figure 6
It is installed in the same way as OAW-AP1221. After the installation is
complete, install the external antenna on OAW-AP1222 (see figure 7).
Install the antenna as the figure 8:
Status
System start up
Network abnormal
(Interface down)
Network normal,
without SSID created
Figure7
Contacting Alcatel-Lucent Enterprise
Website Support
Table 2: Ethernet Port Pinout
Red
Figure 8
Table 3: OmniAccess Stellar AP LED Meaning
Connect Ethernet
Use the Ethernet port to connect the AP with a twisted pair Ethernet LAN
segment. Use a 4- or 8-conductor, Category 5 UTP cable. The port is an
RJ-45 female connector with the pinouts shown in Table2.
Connector
System running
Main Site
http://enterprise.alcatel-lucent.com
Support Site
http://support.esd.alcatel-lucent.com
Telephone Support
North America
1-800-995-2696
Latin America
1-877-919-9526
Europe
+800 00200100 (Toll Free) or +1(650)385-2193
Asia Pacific
+65 6240 8484
Other Region
1-818-878-4507
[REMAINING SECTIONS INTENTIONALLY LEFT BLANK]

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Alcatel-Lucent Enterprise
Company                         : 微软中国
Create Date                     : 2017:07:06 10:42:23-07:00
KSO Product Build Ver           : 2052-10.1.0.5803
Modify Date                     : 2017:07:06 10:43:18-07:00
Source Modified                 : D:20170706174041
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2017:07:06 10:43:18-07:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:958629d9-b13c-406e-a65e-51b83d78c523
Instance ID                     : uuid:91223c05-3500-461d-a3fd-c40960260c3f
Subject                         : 6
Format                          : application/pdf
Creator                         : Alcatel-Lucent Enterprise
Title                           : OmniAccess Stellar AP1220 Series Installation Guide (060455-10 Rev. B)
Producer                        : Adobe PDF Library 11.0
Page Layout                     : OneColumn
Page Count                      : 2
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AI9TOAW-AP122X

Navigation menu