Contents
- 1. User Manual
- 2. User Manual (Statement)
- 3. User Manual (Statements)
User Manual
Alcatel-Lucent Enterprise OmniAccess Stellar AP1230 Series Installation Guide 060494-10 Rev. B *060494-10 Rev. B* 4- or 8-conductor, CAT5 or better UTP cable of required length. Power sources: a) For full-function running mode (Tri-Radio,2.4GHz 4x4:4 + 5GHz 4x4:4), the following two kinds of power sources are acceptable 1) IEEE 802.3at compliant PoE source with LLDP protocol supported, 60W, output voltage DC 48V(nominal), or 2) AC/DC adapter (sold separately) ,output voltage DC 48V, output current > 0.75A When both power sources are available, DC power takes priority over PoE b) For Power safe mode (Tri-Radio,2.4GHz 2x2:2 + 5GHz 2x2:2, USB disabled), an IEEE 802.3at compliant PoE source is acceptable A PC terminal or a notebook Summary of installation Steps Unpack the AP box and check all contents Install the AP bracket on ceiling or wall Installing the AP Connecting required cables Power connection Verifying post-installation connectivity AP provisioning AP is a radio transmission device and subject to governmental regulation. Network administrators must comply with local regulations. Package Contents Item Name Access Point Quick Start Guide Installation Guide Regulatory Compliance and Safety Information User Guide Info Card Mounting Bracket (15/16”) Mounting Bracket (9/16”) Qty Unit Pcs Pcs Pcs Pcs Pcs Pcs Pcs Figure 2: AP Front View Identifying Specific Installation Locations You can mount the OmniAccess Stellar AP on a ceiling rail (using the shipped bracket in the box) or on a wall (using the wall mount adapter, sold separately). You should first determine the location of the installation. The installation position is located at the center of the required coverage area and should be free from obstructions or obvious sources of interference. Minimize the number of obstructions (such as walls) between the AP and user terminals. Electronic equipment or devices (such as microwave ovens) which may produce radio frequency noise should be away from the installation position of the AP. It is strictly prohibited to install around stagnant water, water seepage, leakage or condensation. Avoid cable condensation or water seepage along the cables connecting to the AP. Temperature and Humidity requirement Operating temperature: 32ºF to 113ºF (0ºC to 45ºC) Storage temperature: -40ºF to 158ºF (-40ºC to 70ºC) Relative Humidity: 10% to 90% non-condensing AP Installation Figure 1: Product Packing Inform your ALE sales representative of incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed. Additional mounting kits for use with the OmniAccess Stellar AP1230 series access points are sold separately. Contact your ALE sales representative for details. Unboxed OAW-AP1231: Net Weight: 3.34lbs / 1.516kg Dimensions (H×W×D): 9.1 inches × 9.1 inches × 1.81 inches (23 cm × 23cm × 4.6cm) enterprise.alcatel-lucent.com Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view other trademarks used by affiliated companies of ALE holding, visit: enterprise.alcatellucent.com/trademarks. All other trademarks are the property of their respective owners. The information presented is subject to ALE without notice. Neither ALE Holding nor any of its affiliates assumes any responsibility for inaccuracies contained herein. (2017) Device view The OmniAccess Stellar AP is equipped with one hidden LED light that indicates different status with distinct color or flashing. Figure 3: AP Back View Item Name RESET USB 1Gigabit Ethernet 2.5Gigabit Ethernet CONSOLE 48VDC Kensington Lock Slot Specifications Factory reset. Press reset button for 5s, AP LEDs will quickly flash for 3s, then AP will restart and restore factory configurations. USB 2.0 host interface (Type A connector) 1x 10/100/1000BASE-T autosensing (RJ-45) port, Power over Ethernet (PoE) 1x 100/1000/2.5GBASE-T autosensing (RJ-45) port, Power over Ethernet (PoE) The console port is an RJ-45 female connector and can be used to connect to a terminal for direct local management. Note: Currently for use by Service & Support only. The AP has a single 48V DC power jack socket to support powering through an AC-to-DC power adapter. If PoE is not available, an optional AC-DC adapter kit (sold separately) can be used to power the AP. The AP is equipped with a Kensington lock slot for additional security. Table 1: External Interfaces Pre-Installation Checklist Before installing your OmniAccess Stellar AP, be sure that you have the following items: Using Ceiling Mounting Bracket Make sure the AP fits securely on the ceiling tile rail when hanging the device from the ceiling, poor installation could cause it to fall onto people or equipment. The OmniAccess Stellar AP has been shipped with two mounting brackets for 9/16” and 15/16” ceiling rails. Following is the general sequence to install the AP with the mounting bracket. Pull the cables through a prepared hole in the ceiling tile near where the AP will be placed. Place the bracket against the back of the AP, insert by aligning the slot on the backside with the hanging feet on both sides of the bracket (see Figure 4). Push the bracket along the direction of the arrow until it locks in the slot (see Figure 4). Connect the cable to the port on the AP. Hold the AP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 20-degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile. Pushing toward the ceiling tile, rotate the AP clockwise until the device clicks into place on the ceiling tile rail (see Figure 5). Flash System running ON System running ON System running Flash Flash System running Flash Flash Figure 4: Attaching the Ceiling Mounting Bracket Flash System running Network normal, without SSID created Network normal, single band working, either 2.4GHz or 5Ghz Network normal, dual bands working, 2.4Ghz and 5Ghz are both working Red and Blue LEDs alternate flashing in specific frequency; OS upgrading 3 LEDs alternate flashing in specific frequency; Used for locating an AP Table 3 OmniAccess Stellar AP LED Meaning Console Port The serial console port allows you to connect the AP to a serial terminal or a laptop for direct local management. This port is an RJ-45 female connector with the pinouts described in Table 4. Figure 7 Note: Currently for use by Service & Support only. Connector Signal Name TXD GND GND RXD Function Pins not listed are not connected Figure 5: Mounting the AP Connect Ethernet Use the Ethernet port to connect the AP with a twisted pair Ethernet LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable. The port is an RJ-45 female connector with the pinouts shown in Table2. Ethernet Port Signal Pin Function /RJ45 Female Name BI_DA+ Bi-directional pair +A, PoE Negative BI_DABi-directional pair -A, PoE Negative BI_DB+ Bi-directional pair +B, PoE Positive BI_DC+ Bi-directional pair +C, PoE Positive BI_DCBi-directional pair -C, PoE Positive BI_DBBi-directional pair -B, PoE Positive BI_DD+ Bi-directional pair +D, PoE Negative BI_DD- Bi-directional pair -D, PoE Negative Pin Table 4: Console Port Pinout Configuring the OmniAccess Stellar AP Refer to the Quick Start Guide and Configuration Guide for complete details. If both PoE and DC power are available, the use of DC is preferred. OmniAccess Stellar AP supports the power adapter provided by ALE ONLY. Verifying Post-Installation Connectivity The LED on the AP can be used at this point to verify that the AP is receiving power and initializing successfully (see Table 3). Red ON ON Flash Blue Green Time Line Power on Bootloader-OS loading System running Status System start up Network abnormal (Interface down) The external antennas are sold separately. Unboxed OAW-AP1232 (external antenna) Net Weight: 3.48lbs / 1.58kg Dimensions (H×W×D): 9.1 inches × 9.1 inches × 1.81 inches (23 cm x 23cm × 4.6cm) Device view Contacting Alcatel-Lucent Enterprise Website Support Table 2: Ethernet Port Pinout Connect Power Sources Confirm that the Ethernet cable is loaded either with 48V DC (nominal) 60W/802.3at compliant PoE source (with LLDP protocol) for full-function running mode, or just with 802.3at compliant PoE source for power safe mode. If not, connect by using the ALE 48V AC-DC adapter kit (sold separately) to the DC Power Socket and AC power jack. Figure 8: With external antennas Main Site Support Site http://enterprise.alcatel-lucent.com http://support.esd.alcatel-lucent.com North America Latin America 1-800-995-2696 1-877-919-9526 Europe +800 00200100 (Toll Free) or +1(650)385-2193 Asia Pacific Other Region +65 6240 8484 1-818-878-4507 Telephone Support Figure 6 It is installed in the same way as OAW-AP1231 for the AP installation. In Figure 7, it is shown the way to install the external antennas. [REMAINING SECTIONS INTENTIONALLY LEFT BLANK]
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2018:01:19 11:29:46+08:00 Creator Tool : Microsoft® Office Word 2007 Modify Date : 2018:01:22 17:40:33+08:00 Metadata Date : 2018:01:22 17:40:33+08:00 Format : application/pdf Creator : 深圳2 Producer : Microsoft® Office Word 2007 Document ID : uuid:def126be-a196-4c6a-a6fc-8e6551037086 Instance ID : uuid:ce4115d7-c803-44f0-8138-225eb3f594b9 Page Count : 2 Language : zh-TW Author : 深圳2EXIF Metadata provided by EXIF.tools