USER MANUAL
RDR 417
RDR 417 USB contactless reader
user manual
ASK R&D
ASK
2260 Route des Crêtes
06560 VALBONNE SOPHIA ANTIPOLIS
Tel : 04 97 21 40 00
Fax : 04 92 38 93 21
Réf. : RD-MU-05179-10
1 / 13
R&D001-Form1
TABLE OF CONTENTS
SCOPE OF MANUAL
READER DESCRIPTION
2.1
Characteristics
2.1.1
Features
2.1.2
Main applications
2.1.3
Cards & tags supported
2.2
Architecture
Mechanical aspects
2.3.1
Attached USB cable definition
2.3.2
Adhesive cover film
READER SETUP
2.3
3.1
Unpacking and inspection
3.2
Installing the SAM in the reader
3.3
Reader connection to USB
3.3.1
Driver installation
3.3.2
Software
HOW TO USE THE READER
10
4.1
Contactless operation
10
4.2
Cleaning
10
STANDARD COMPLIANCE
11
5.1
FCC compliance statements
11
5.2
CE compliance statement
11
5.3
Annexe
5.3.1
Coupler board
5.3.2
Antenna board
5.3.3
Assembly
ASK R&D
ASK
2260 Route des Crêtes
06560 VALBONNE SOPHIA ANTIPOLIS
Tel : 04 97 21 40 00
Fax : 04 92 38 93 21
12
12
13
13
Réf. : RD-MU-05179-10
2 / 13
R&D001-Form1
USER MANUEL
RDR 417
USB contactless reader
SCOPE OF MANUAL
This manual describes ASK RDR 417 contactless reader main features and setup information.
This manual is intended for use by end users.
Sam installation requires a “Philips” screwdriver for case opening.
READER DESCRIPTION
The RDR417 is a high speed, low cost, multi-standard, multi-application USB contactless
reader. It supports all current ISO dual interface / contactless cards and contactless paper
tickets.
2.1 Characteristics
The RDR417 reader is based on CPL407 coupler platform.
2.1.1 Features
• ISO 14443 A/B - ISO 15693
ISO/IEC 14443-2:2001/FPDAM 2 2004-03-17
• Contactless paper tickets
• High power class 1 RF interface
• Compatible with Windows 98 SE, Me,
2000, XP
• PC/SC driver, ASK (dll) proprietary driver, or virtual COM driver
available
• High-speed communication: 106 Kb/s up to
847 Kb/s
• Cryptographic security management with
embedded SAM slot + Mifare® asic
• USB 2.0 connection for PC-based applications
• Powered via USB port (500 mA port)
• CE Mark: EN300330, EN301 489-3, EN60950-1
• FCC class B part 15
• 3 control LEDs
• 178 mm x 125 mm x 26 mm
• Weight: 160 g
• Operating temperature: 0°C to 50°C
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
3 / 13
USER MANUEL
RDR 417
USB contactless reader
2.1.2 Main applications
• Identity
• Banking
• Logical / physical access control
• PC/ workstation add-on
2.1.3 Cards & tags supported
Mifare® standard, Mifare®4K, Mifare® Pro,
Mifare Ultra Light, Mifare DESFIRE, Smart MX,
SLE 55Rxx, SLE 66CL1605, SLE 66CLX320P, SR176,
SRIX4K, Sharp B, all ASK cards and tickets.
ICODE SLI.
2.2
Architecture
This diagram describes the general architecture of the RDR417 reader.
The reader is an assembly of the ASK CPL407 USB coupler, and its dedicated
local antenna ANT400.
27.120 MHz
osc
3.3V
regulator
mini B
mini B
USB A
CPU
FPGA
USB interface
13.56 MHz
RC632
13.56 MHz
5V DC
converter
RF
emitter
RF
receiver
ANT 400
4.52 MHz
1m USB cable
6 MHz
3.6864 MHz
SAM
interface
CPL407
Leds
RDR417
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
4 / 13
USER MANUEL
RDR 417
USB contactless reader
Mechanical aspects
FERRITE
2.3
Case: ABS
light grey (RAL 7035)
Soft side "grip" plastic:
grey (RAL 7012)
117
diam2.8
7.5
7.5
24
9.5
79
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
5 / 13
USER MANUEL
RDR 417
USB contactless reader
2.3.1 Attached USB cable definition
Mini-B-to-USB Type A
Length: 1m
Current: 1.0A
Contact resistance: 50mΩ max.
Over-Mold: Gray Polyvinyl Chloride, UL 94V-0
Ferrite: Wurth 7427114
2.3.2 Adhesive cover film
An adhesive cover film is added to the top case.
It supports ASK logo.
For volume order, it may be modified in order to support customer’s logo.
Material is polycarbonate 250 µm, and adhesive 3M 468.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
6 / 13
USER MANUEL
RDR 417
USB contactless reader
3.1
READER SETUP
Unpacking and inspection
For end user unity packaging, the RDR 417 is delivered with an installation CD.
It includes user manuals in *;pdf format, USB drivers, and a few demonstration software.
3.2
Installing the SAM in the reader
In most applications, one SAM (Security Application Module) is required. This
component is provided separately, so to set a SAM, the plastic case should be
opened.
Caution: For SAM installation, it is mandatory to disconnect reader from USB port.
For opening, unscrew the cover screw using a “Philips” head screwdriver.
Open the case, and remove the lower case from the assembly.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
7 / 13
USER MANUEL
RDR 417
USB contactless reader
Caution: In a first time, µSIM shape SAM must be gently inserted in the opened
cover, then in a second time the cover should be closed and locked.
Close and screw again the reader before use.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
8 / 13
USER MANUEL
RDR 417
USB contactless reader
3.3
Reader connection to USB
Caution: The RDR417 is an USB powered reader.
Because of its high RF power, it has to be imperatively connected to a native USB port of a
computer, or a self powered USB hub able to deliver up to 500mA according to USB standard.
To avoid improper operation:
Prefer connection to a rear USB port directly handled by the motherboard.
Avoid use of USB extension cable.
Avoid replacement of the existing 1 meter USB A to miniB cable by a longer one.
Note:
Some PCMCIA USB2.0 extension boards for handheld computers are not able to deliver 500
mA.
3.3.1 Driver installation
Connect the reader to the proper USB port.
Windows will detect it as a new device.
Insert the installation CD, and follow the instructions on screen.
You will be asked to choose between:
Standard virtual COM driver,
Card reader ASK (dll) proprietary driver,
or PC/SC driver.
Chosen driver will depend on the customer application software requirements.
3.3.2 Software
The RDR is delivered by default with an embedded application firmware called CSC which
supports the ASK cards and C.ticket families.
This firmware is upgradeable by download.
The external LEDs of the reader can be controlled by customer applicative software using
CSC software commands. On power on, red led is active.
Complete driver installation, furnished demonstration software, and tools for customer
application software development are described in a specific “software user manual”
document.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
9 / 13
USER MANUEL
RDR 417
USB contactless reader
4.1
HOW TO USE THE READER
Contactless operation
All the top surface of RDR 417 reader is active.
Card must be laid on the top of the reader.
4.2
Cleaning
To clean, simply wipe with a wet cloth.
Abrasive or solving products are prohibited, except usual cleaning product for panes.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
10 / 13
USER MANUEL
RDR 417
USB contactless reader
5.1
STANDARD COMPLIANCE
FCC compliance statements
This equipment has been tested and found to comply with the radiated limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a
reasonable protection against harmful interferences in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
the correct interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions. (1) This device may not cause harmful interferences. And (2) this device must
accept any interference received, including interference that may cause undesired operation.
The ASK RDR 417 reader was submitted and a grand of authorization received from the FCC
as device under the intentional radiator requirements of Part 15, Subpart C.
Compliance accessory: The accessory associated with this equipment is a shielded USB
cable including clipped ferrite core. This accessory is required to be used in order to ensure
compliance with the FFC rules.
Caution : Any changes or modification not approved by ASK could void user’s authority to
operate the equipment. Switching power mode adaptors are prohibited.
It is strictly prohibited to remove the ferrites from the device.
5.2
CE compliance statement
The ASK RDR 417 reader is in conformity with European requirements, this product has been
assessed to the following standard:
EN 300330
EN 301 489-3
EN 60950-1
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
11 / 13
USER MANUEL
RDR 417
USB contactless reader
5.3
Annexe
RDR 417 is an assembly of a control board called ”coupler board”, and an antenna board.
5.3.1 Coupler board
The coupler board contains a microprocessor, non-volatile memory and a radio frequency
transmitting circuitry. This board communicates with smart cards via RF link (provided by the
antenna board), and to the terminal via “USB to serial” interface. The coupler platform is a
CPL 4xx, which can be purchased separately as OEM product.
This coupler board is compliant with ISO/IEC14443-2 directives (Radio frequency power and
signal interface). Communications can be executed according to the type A or type B of the
directive.
It also complies with ISO/IEC15693.
(NB: remote antenna connector is only available on OEM coupler version)
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
12 / 13
USER MANUEL
RDR 417
USB contactless reader
5.3.2 Antenna board
The antenna ANT 400 is a coil antenna directly designed on a printed circuit board.
No adjustment is required.
It can be purchased separately as OEM product.
5.3.3 Assembly
Inside the plastic case, these boards are stacked together, using M3 x 10 spacers.
Internal SMD Leds are replicated to front panel using light guides.
ASK R&D
Réf. : RD-MU-050179-10
Copyright ASK SA - 2006
13 / 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Subject                         : 
Title                           : 
Creator                         : Visage eXPert PDF
Author                          : 
Create Date                     : 2006:01:28 23:29:44
Producer                        : VSPDF.DLL http://www.visagesoft.com
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QYERDR41X

Navigation menu