ASM Assembly Systems and KG 03146441 RFID Read Module User Manual
ASM Assembly Systems GmbH & Co. KG RFID Read Module
User Manual
SIPLACE RFID Read Module
User Manual
03/2017
Edition
All names identified by ® are registered trademarks of the ASM Assembly Systems GmbH & Co. KG. The
remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes
could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information given in this publication is reviewed regularly and any necessary corrections are included in
subsequent editions.
Copyright © ASM Assembly Systems Technical data subject to change
ASM Assembly Systems GmbH & Co. KG Item-no.: 00198325-01
Rupert-Mayer-Strasse 44
81379 München
Germany
www.asm-smt.com
SIPLACE RFID Read Module / User Manual 03/2017 Edition
4
1Introduction
This manual provides technical information on the SIPLACE RFID Read Module.
1.1 History of Changes
Changes to the original manual are listed below:
Version Date Author / Dept Description
1.0 20-Mar-2017 Jason / R&D
1.2 FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment. This device complies with Part 15 of the
FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
SIPLACE RFID Read Module / User Manual 03/2017 Edition
5
2RFID Read Module
2.1 Description
The RFID Read Module is used in SIPLACE products for specific purpose. It has built-in regulator
circuit and communicates to host controller via UART interface and Flexible Flat Cable.
2.2 Specification
Model No. 03146441-01
Input Voltage 5Vdc ± 10%
Dimension 60mm x 22mm
Operating frequency 13.56MHz
Oscillator frequency 27.12MHz
Communication interface UART
Used protocol ISO/IEC 15693
Modulation ASK 100% According to ISO 15693
Rated Input Power 5Vdc, 75mA
RFID Transceiver CR95HF (ST Microelectronics)
Operating Temperature 0 – 50 °C