ASOKA USA 3050 ENERGY GATEWAY User Manual 3050 User s Manual

ASOKA USA Corporation ENERGY GATEWAY 3050 User s Manual

USERS MANUAL

AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com               Asoka PlugLANTM          3050 Energy Gateway         User’s Manual                    Version: 1.01a           © Copyright 2005. Asoka USA Corporation. All rights reserved. Asoka USA Corporation reserves the right to modify product offerings or specifications without advance notice. No part of this publication may be produced in any format without the express written permission of Asoka USA Corporation.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com 1. Introduction ............................................................................................................................... 3 1.1 Features ............................................................................................................................... 4 1.2 Package ............................................................................................................................... 4 2.  Hardware Installation ................................................................................................................. 4 2.1 Connect Device and PC ...................................................................................................... 4 2.2 Set Device in AC Power Panel Box .................................................................................... 5 3.  3050 Configuration .................................................................................................................... 7 3.1 Login ................................................................................................................................... 7 3.2 System ................................................................................................................................. 7 3.2.1 System Details .......................................................................................................... 7 3.2.2 Date & Time ............................................................................................................. 8 3.2.3 System Password ...................................................................................................... 9 3.2.4 System Logs ........................................................................................................... 10 3.2.5 System Reboot ....................................................................................................... 11 3.2.6 System Backup ....................................................................................................... 12 3.2.7 Firmware ................................................................................................................ 13 3.3 LAN .................................................................................................................................. 14 3.3.1 IP Configuration ..................................................................................................... 14 3.3.2 PowerView ............................................................................................................. 15 3.3.3 NEK Setting ........................................................................................................... 16 3.4 Advanced ........................................................................................................................... 17 3.5.1 Working Mode ........................................................................................................ 17 3.5.2 SNMP Configuration .............................................................................................. 18 4. Specification of power meter .................................................................................................. 20 4.1 Specification...................................................................................................................... 20                  Technical Support
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com  You can download latest software from our website. If you have any question or difficulty during installation or using PlugLANTM  3050, please contact our technical support engineer. NOTE:  THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY     RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED          MODIFICATIONS TO THIS EQUIPMENT.                   SUCH MODIFICATIONS COULD VOID THE USER.¡¥S AUTHORITY                    TO OPERATE THE EQUIPMENT.                       About User’s Manual         User’s Manual of 3050 is released in August, 2008, the version is           1.01a. This manual illustrate how to installation and configure 3050.               Please spend some time to read this manual before using our 3050.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com 1. Introduction Thanks for your selection of Asoka USA PlugLANTM 3050. We are devoting to provide powerful, high-performance and applied power line network system. The product is designed for hotel, office, apartments. It provides a full commercial network solution with PLC technique. It should be set in user’s power panel box, it has 21 channels of meter which can record real time AC power values (KWH, V, A, KW and PF) from each channel, so user can monitor their household appliances through internet easily and observably. 1.1 Features   Complies IEEE 802.3, IEEE 802.3u, IEEE802.3x, IEEE 802.3z/ab standards  Complies with IEEE802.1Q VLAN tag  Complies with HomePlug 1.0    Supports QAM 256/64/16,DQPSK,DBPSK and ROBO modulation schemes  Supports OFDM with patented signal processing techniques  Supports up to 85M bps with PLC  Supports SNMP  Supports RIPV1/2 including static routing and dynamic routing  Supports Web-based GUI (CGI , SSL)  Supports TFTP for firmware upgrade  Provide 3 main meters and 18 sub meters which can record real time AC power values (KWH, V, A, KW and PF)    Two 4G USB flash disks inside which can backup the real time AC power values 1.2 Package Please make sure the package with contents as below: z 1 3050 z 1 CAT-5 UTP Cable z User’s Manual z 1 CD with Product Document z 3 200A main CTs (current transformer) z 6 30A sub CTs (current transformer) If you find any item as upper lost or damaged, please contact the local sales.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com 2. Hardware Installation 2.1 Connect Device and PC a. Connect 3050 to AC power with wires P1 (Phase1) and N (Neutral), please see Figure 1. b. Connect 3050 to a PC or Laptop with CAT5 cable through RJ45 port. c. Set network configuration of PC to communicate with 3050. The default IP address of 3050 is as below: z Default LAN IP address:    192.168.1.250 d. Power on 3050, Use command “ping” in PC side to test the connection between the Gateway and PC. For example, you connect PC to LAN port, the IP address of PC should be set to “192.168.1.x” (1<x<255 and x!=253), the network mask is “255.255.255.0”.   2.2 Set Device in AC Power Panel Box a. Set the CTs: make the AC wires which we need monitor through CTs. b. Set 3050 in the AC power panel box and Connect wires of CTs to 3050 as Figure 2. c. Connect 3050 and AC power with wires P1 (Phase1), P2 (Phase2), P3 (Phase3) and N (Neutral) as Figure 2.   d. The device is powered on when LED power light, see Figure 1. e. The PLC signal have been received when LED plc flash, see Figure 1.   Figure1. 3050 silkscreen
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com  Figure2. 3050 Setting Drawing
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com 3. Device Configuration 3050 provides Web-based GUI for user to configure the device. It means user can use any web explorer (Internet Explorer, Netscape Communicator etc.) to implement configuration of 3050.   3.1 Login Connect monitor PC to RJ45 port, Start web explorer program, input corresponding IP address of 3050, then will display login page as Figure 3, input correct User ID & Password, then can enter management interfaces.              Figure3. System Login  The default User ID is “admin” and the default Password is “welcome”. Please remember to modify User ID and Password after you login successfully first time.   3.2 System System configuration provides interface to view the general configuration and status and set general configuration of the device including Date & Time, Password & User ID etc. It also provides interface to backup configuration, reset system, update firmware etc. 3.2.1 System Details When you login the web-based GUI of 3050, the pages as below will be shown as Figure 4 of the system details including status and basic configuration.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure4.  System Details  z From the page, we can find that there is one main menu in the upper part for configuration. z The submenu in the left part of the page show all items for each menu selected. 3.2.2 Date & Time To set Date & Time of the gateway, and set the Time Interval for Power Meter, click submenu “SYSTEM-> time”, the page as Figure 5 will display.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure5.  System Time  The screen contains the following details: 1. NTP Server:       To enter the IP address of NTP Server 2. Time Interval:      To set the Time Interval of reading data   from Power Meter Click button “Apply” to save the configuration. 3.2.3 System Password To change User ID or Password of the gateway, click submenu “SYSTEM-> password”, the page as Figure 6 will display.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com                     Figure6.  System Password  z Input old user id in the first text box z Input new user id in the second text box (input old user id means keep user id without change ) z Input current password in the third text box z Input new password in the fourth text box z Re-input new password in the fifth text box z Click button ‘Apply’ begin set new user id or password, then a new page will show the result of the setting 3.2.4 System Logs To view the system logs and set some parameters of logs, click submenu “SYSTEM->System Logs”, a page as Figure 7 will display.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure7. System Logs  z The upper list box shows the current system logs z Click button “Download”, a dialog will display to begin log file downloading z Click button “Clear” to delete all current logs   z Click button “Refresh” to refresh this page to show latest logs 3.2.5 System Reset To reset 3050 or set the configuration to factory default, click submenu “SYSTEM->Reset”, a page as Figure 8 will be shown.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure8. System Reset  z To reset system, click button “System Reset”. If you confirm your decision, please wait a minute for the system reboot. z To restore the factory setting to the gateway, click button “Factory Default”. If you confirm your decision, please wait a minute because the system should be rebooted. 3.2.6 System Backup To save the system configuration or restore the system configuration with saved file, click submenu “SYSTEM-> Backup”, a page as Figure 9 will be shown.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure9. System Reset  z To save the system configuration in local disk, click button “Back Settings”, then a windows dialog will be pop to guide you how to save the file to local disk. z To restore settings of 3050, click button “Browser” to select the configuration file which saved in local host. Then click button “Restore Settings” begin to restore. 3.2.7 Firmware upgrade To upgrade firmware, click submenu “System->Upgrade”, then a page as Figure 10 will be displayed.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com      Figure10. Firmware Upgrade  z Click button “Browse” to select firmware file, then one windows dialog will be popped up for user to select local file z Click button “Update” to begin update, if you confirm your decision, it will update the firmware and reboot the gateway, the process will cost about 2 minutes.   3.3 LAN   LAN menu provides interface to set IP address of 3050, view and scan devices, view temperature or control relay and set NEK of 3050. 3.3.1 IP Configuration To configure the IP Address of 3050, click on the link IP Configuration in the left submenu, a screen is displayed as shown in Figure 11.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure11. IP Address Configuration  The screen contains the following details: 3. IP Address:    To enter the IP address of 3050 4. Subnet mask:      The fix subnet mask is “255.255.255.0” Click button “Apply” to save the configuration and renew system IP address. 3.3.2 Power View To view and scan devices in the same power line network with 3050, also view its temperature or control its relay, click on the link Power View of the left submenu, a screen is displayed as shown in Figure 12.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com      Figure12. Power View  The screen contains the following details. 1. Scanned Devices:    The No. of the device have been scanned 2. MAC Address:      The MAC address of the device 3. Temperature:           where the device located Click button “Scan Now” to refresh the device list. Select either device, can control its relays as the following details. z #1 Switch on/off To switch on/off relay1 in the thermostat 202 z #2 Switch on/off To switch on/off relay2 in the thermostat 202 3.3.3 NEK Setting To set NEK of 3050, click on the link NEK Setting of the left submenu, a screen is displayed as shown in Figure 13.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com   Figure13. NEK setting  z Input new NEK configuration of the power line network z Click button “Apply” to save and set the configuration  3.4 Advanced Advanced Menu provides the interface for advanced administer to set working mode and 3050 including SNMP. 3.4.1 Working Mode To enable Gateway Mode, click on the link Working Mode in the left submenu, a screen is displayed as shown in Figure 14.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com      Figure14. Working Mode  Click button “Working Mode” to enable Gateway Mode.  3.4.2 SNMP Configuration To view or set SNMP configuration, click on the link SNMP Configuration of the left submenu, a screen is displayed as shown in Figure 15.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com      Figure15. SNMP Configuration  The screen contains the following details. z Enable/Disable SNMP:  To enable or disable SNMP agent. Select the check box to enable SNMP agent   z Server IP:    To enter the IP address of the SNMP Server Click button “Apply” to save the information had entered.
AsokaUSA PlugLANTM 3050 User’s Manual    V1.01a Asoka USA Corporation    Tel: +1 650 286 1700    2344-A Walsh Avenue Santa Clara, CA 95051 USA   Fax: +1 650 286 1790                                                                                     URL: www.asokausa.com 4. Specification of Power Meter   3050 provides 3 main meters and 18 sub meters for users. 4.1 Specification Voltage         90V-265VCurrent   Main: 10(200A)  Sub: 5(30A) Frequency         50/60 Hz Environment temperature  -20~65℃ Min. load current     20mA AC @ 5(30A) 40mA AC @ 10(200A) Precision for KWH  0.01kWh Scale for KWH  XXXXXX.XX Precision for V  0.01V Scale for V  XXXX.XX Precision for A  0.01A Scale for A  XXXX.XX Precision for KW  0.001kW Scale for KW  XXX.XXX Precision for PF  0.01 Scale for PF  XXXX.XX Meter level  Class 1 Max. supply current     100mA DC
AsokaUSA PlugLANTM 3050 User’s Manual                                                 V1.01a  FCC Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of FCC Rules.   Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu