Model No. LL94AR- 7
2016. 02
1 . Spe cific Fe a t u r e s
3 levels key (RFID tag) management system
Support Mifare Classic, DESFire EV1, Ultralight
Comfortable grip feeling with round handle front
Intuitive hidden LED Icons
Shared use mode or assigned use mode
Burglar alarming when opening by force (O
Warning alarms for low battery or abnormal status
External 9V battery connector for low battery
Melody on-off setting
In-use LED icon
Auto locking or manual locking
1 year battery life with 3 AA type alkaline batteries
Material: PC/ABS
2 . D im e n sion s
Front: 98(H) * 66(W) * 29.2(T) mm
Rear: 132(H) * 66(W) * 29(T) mm
3 . Su ppor t e d door t h ick n e ss
Size A: 15~20mm (0.59~0.78 inches)
- Size B: 20~25mm (0.79~0.98 inches)
- Size C: 25~30mm (0.99~1.18 inches)
 Contact us for less than 15mm or larger than 30mm
4 . Pa r t N a m e s
5 . Su ppor t e d k e y le ve ls
RF key levels
Max no. of RF key
Owner Key
Master Key
20
User Key
20
Cleaner Key
20
6 . Ch a n ge M ode Opt ion s
Need to use “Lock Manager” software and USB gender for changing the
options.
Functions
Use of Key
Locking type
Options
No. of Beep
Shared Use
Assigned Use
Factory Setting
Default
Auto Locking
Manual Locking
Default
High
Default
Mid
Beep Levels
Low
Off
In Use LED
Cleaner Key
On
Off
Default
Enable Cleaner Key
Default
Disable Cleaner Key
7 . LED I con s
Icon
Function
Color
Status
Green
Open,
registered
Red
Closed
Locking Status
8 . Re gist e r in g a n d Usin g RFI D k e ys

LL94AR using IRDA sensor for waking up the lock from power saving
mode (sleep mode). Direct sunlight or strong three wave light bulb may
interfere the IRDA sensing function. And the sensor starts auto-tuning
function when the battery is changed. Auto tuning takes around 20
seconds. Please do not cover the RF sensing area during the auto-tuning.
A. Register an Owner key
First used RF card became an Owner key.
① Install LL94AR into the locker.
② Insert 3 AA alkaline batteries.
③ Wait for auto-tuning time, around 20 seconds.
④ Touch any RF card for registering it as an Owner key.
Beeps 3 times and blinking green LED if the Owner key registering is
done.
1 Owner key can be registered for a LL94AR. Owner key cannot access
the lock.
B. Register Master key(s)
① Touch the Owner key (No need to use Owner key at the first time)
② Touch an extra RFID card (LED blinks during registration mode for 8
seconds). Beep 3 times and green LED blinks if the registration is done.
③ Touch another RFID card for up to 20 in sequence or touch same card
twice to end the registration.
 Exam ple: Touch A card ( 4 seconds) – t ouch B card – t ouch C card –
t ouch C card again
 Result : Three ( A, B and C) Mast er cards has been regist ered.
- Master key opens the lock. But cannot lock.
C. Register & using User key(s)
① Touch any Master card
② Touch an extra RFID card (LED blinks during registration mode for 8
seconds). Beep 3 times and green LED blinks if the registration is done.
③ Touch another RFID card for up to 20 in sequence or touch same card
twice to end the registration.
 Exam ple: Touch any Mast er card – t ouch A card – t ouch B card –
t ouch C card – t ouch C card again
 Result : t hree ( A, B and C) User cards has been regist ered.
The User key can lock or unlock LL94AR.
D. Change or delete User key (while lost user key)
i. Touch any Master key for deleting all registered User keys.
ii. Register new User cards.
9 . I n st a lla t ion D r a w in gs
( For Righ t H in ge / Cove r e d D oor )
( For Le ft H in ge / Em be dde d D oor )
1 0 . Ou t of Ba t t e r y
 There will be battery warning alarms, 5
beeps, if the battery is almost runs out.
Standard 9 V external battery can be used
to operate the lock. (No polarity on the
external 9V battery contactors)
 Use any registered Master card to open.
9V Battery
1 1 . Re se t M e m or y ( Cle a r M e m or y)
 Possible to delete all registered RF keys and return all of the lock
functions back to factory default setting.
1. Coupling the “RESET” soldering points with a sharp tweezers or similar
tool and touch the RF sensing area by hand to clear the memory.
- Beep 1 time if the reset was done.
- Register all keys again.
1 2 . Em e r ge n cy Ope n in g
 LL94AR can be unlocked without damage if the lock does not work at all.
Try to open with 9V external battery before doing this emergency opening
process.
1. Unscrew the side bottom set-screw with set-screw wrench.
2. Rotate the front bezel to clockwise and take out the front core.
3. Press down inside open pin with “─” driver.
4. Insert the emergency opening pin into the emergency opening hole.
5. Press the emergency opening pin to the right end and open the door.
 The lock does not work at all after this emergency opening. Return the
lock to the authorized dealer for rework.
[END]
Marking
Made in Korea
Model
Lot No
Power
Mfr.
LL94AR-7
XXXXX
(RPxxxxxxxx)
4.5V DC (AA 1.5 x 3)
ASSA ABLOY KOREA Co., Ltd Unilock
This device complies with part 15 of FCC Rules.
Operation is subject to the following two conditions:
(1) This devie may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC ID: 2AJUHLL94AR-7
www.assaabloyhospitality.com
2200

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Create Date                     : 2016:09:22 16:46:54+09:00
Modify Date                     : 2016:09:23 13:40:59+09:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2016:09:23 13:40:59+09:00
Format                          : application/pdf
Document ID                     : uuid:8293c0c1-4b83-4f38-b55c-bb53d9822381
Instance ID                     : uuid:c2357fc5-d9d3-4d84-9c49-00a1bef1be35
Page Count                      : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AJUHLL94AR-7

Navigation menu