ASSALOY KOREA Unilock LL94AR-7 Digital Locker Lock User Manual
ASSA ABLOY KOREA Co., Ltd Unilock Digital Locker Lock Users Manual
Users Manual
Model No. LL94AR- 7 2016. 02 1 . Spe cific Fe a t u r e s 3 levels key (RFID tag) management system Support Mifare Classic, DESFire EV1, Ultralight Comfortable grip feeling with round handle front Intuitive hidden LED Icons Shared use mode or assigned use mode Burglar alarming when opening by force (O Warning alarms for low battery or abnormal status External 9V battery connector for low battery Melody on-off setting In-use LED icon Auto locking or manual locking 1 year battery life with 3 AA type alkaline batteries Material: PC/ABS 2 . D im e n sion s Front: 98(H) * 66(W) * 29.2(T) mm Rear: 132(H) * 66(W) * 29(T) mm 3 . Su ppor t e d door t h ick n e ss Size A: 15~20mm (0.59~0.78 inches) - Size B: 20~25mm (0.79~0.98 inches) - Size C: 25~30mm (0.99~1.18 inches) Contact us for less than 15mm or larger than 30mm 4 . Pa r t N a m e s 5 . Su ppor t e d k e y le ve ls RF key levels Max no. of RF key Owner Key Master Key 20 User Key 20 Cleaner Key 20 6 . Ch a n ge M ode Opt ion s Need to use “Lock Manager” software and USB gender for changing the options. Functions Use of Key Locking type Options No. of Beep Shared Use Assigned Use Factory Setting Default Auto Locking Manual Locking Default High Default Mid Beep Levels Low Off In Use LED Cleaner Key On Off Default Enable Cleaner Key Default Disable Cleaner Key 7 . LED I con s Icon Function Color Status Green Open, registered Red Closed Locking Status 8 . Re gist e r in g a n d Usin g RFI D k e ys LL94AR using IRDA sensor for waking up the lock from power saving mode (sleep mode). Direct sunlight or strong three wave light bulb may interfere the IRDA sensing function. And the sensor starts auto-tuning function when the battery is changed. Auto tuning takes around 20 seconds. Please do not cover the RF sensing area during the auto-tuning. A. Register an Owner key First used RF card became an Owner key. ① Install LL94AR into the locker. ② Insert 3 AA alkaline batteries. ③ Wait for auto-tuning time, around 20 seconds. ④ Touch any RF card for registering it as an Owner key. Beeps 3 times and blinking green LED if the Owner key registering is done. 1 Owner key can be registered for a LL94AR. Owner key cannot access the lock. B. Register Master key(s) ① Touch the Owner key (No need to use Owner key at the first time) ② Touch an extra RFID card (LED blinks during registration mode for 8 seconds). Beep 3 times and green LED blinks if the registration is done. ③ Touch another RFID card for up to 20 in sequence or touch same card twice to end the registration. Exam ple: Touch A card ( 4 seconds) – t ouch B card – t ouch C card – t ouch C card again Result : Three ( A, B and C) Mast er cards has been regist ered. - Master key opens the lock. But cannot lock. C. Register & using User key(s) ① Touch any Master card ② Touch an extra RFID card (LED blinks during registration mode for 8 seconds). Beep 3 times and green LED blinks if the registration is done. ③ Touch another RFID card for up to 20 in sequence or touch same card twice to end the registration. Exam ple: Touch any Mast er card – t ouch A card – t ouch B card – t ouch C card – t ouch C card again Result : t hree ( A, B and C) User cards has been regist ered. The User key can lock or unlock LL94AR. D. Change or delete User key (while lost user key) i. Touch any Master key for deleting all registered User keys. ii. Register new User cards. 9 . I n st a lla t ion D r a w in gs ( For Righ t H in ge / Cove r e d D oor ) ( For Le ft H in ge / Em be dde d D oor ) 1 0 . Ou t of Ba t t e r y There will be battery warning alarms, 5 beeps, if the battery is almost runs out. Standard 9 V external battery can be used to operate the lock. (No polarity on the external 9V battery contactors) Use any registered Master card to open. 9V Battery 1 1 . Re se t M e m or y ( Cle a r M e m or y) Possible to delete all registered RF keys and return all of the lock functions back to factory default setting. 1. Coupling the “RESET” soldering points with a sharp tweezers or similar tool and touch the RF sensing area by hand to clear the memory. - Beep 1 time if the reset was done. - Register all keys again. 1 2 . Em e r ge n cy Ope n in g LL94AR can be unlocked without damage if the lock does not work at all. Try to open with 9V external battery before doing this emergency opening process. 1. Unscrew the side bottom set-screw with set-screw wrench. 2. Rotate the front bezel to clockwise and take out the front core. 3. Press down inside open pin with “─” driver. 4. Insert the emergency opening pin into the emergency opening hole. 5. Press the emergency opening pin to the right end and open the door. The lock does not work at all after this emergency opening. Return the lock to the authorized dealer for rework. [END] Marking Made in Korea Model Lot No Power Mfr. LL94AR-7 XXXXX (RPxxxxxxxx) 4.5V DC (AA 1.5 x 3) ASSA ABLOY KOREA Co., Ltd Unilock This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) This devie may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2AJUHLL94AR-7 www.assaabloyhospitality.com 2200
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Create Date : 2016:09:22 16:46:54+09:00 Modify Date : 2016:09:23 13:40:59+09:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2016:09:23 13:40:59+09:00 Format : application/pdf Document ID : uuid:8293c0c1-4b83-4f38-b55c-bb53d9822381 Instance ID : uuid:c2357fc5-d9d3-4d84-9c49-00a1bef1be35 Page Count : 12EXIF Metadata provided by EXIF.tools