ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual FM404 IN100 Bored Instr

ASSA ABLOY Inc. Aperio V3 iN100 RF Module FM404 IN100 Bored Instr

User Manual - FM404 IN100 Bored Instr

Download: ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   FM404 IN100 Bored Instr
Mirror Download [FCC.gov]ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual   FM404 IN100 Bored Instr
Document ID3061070
Application ID3kTdzJZP4aOomCvkTocRcw==
Document DescriptionUser Manual - FM404 IN100 Bored Instr
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize247.95kB (3099433 bits)
Date Submitted2016-07-13 00:00:00
Date Available2016-07-13 00:00:00
Creation Date2016-06-28 15:08:43
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-06-28 15:08:50
Document TitleUser Manual - FM404 IN100 Bored Instr
Document CreatorAdobe InDesign CC 2015 (Windows)

Cylindrical Lockset
IN100 WiFi
Installation Instructions
FM404 07/16
Attention Installer
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
Table of Contents
1) Warning.................................................................................2
2) General Description..............................................................3
3) Specifications / Features.....................................................3
4) Product Illustration..............................................................4
5) Installation Instructions.......................................................6
6) Operational Check............................................................. 16
7) LED Indications..................................................................17
1) Warning
Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class
B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce
dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling
electronic components:
• Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,
latches, and mounting plates especially when mounting electronic components such as readers and controllers onto
the door.
• Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
• Do not touch pins, leads or solder connections on the circuit boards
Copyright © 2016 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
2) General Description
The Corbin Russwin® IN100 lock with Aperio™ Technology makes it easy and cost-effective to bring access
control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect
to an access control system, eliminating the greatest cost and inconvenience of traditional access control –
the wiring at the door.
The IN100 utilizes HID® 125 kHz prox or 13.56 MHz iCLASS® smart card technology, and all technology
features are supported by the physical security of Corbin Russwin ANSI/BHMA Grade 1 hardware.
This product is operated by six (6) “AA” alkaline batteries. Corbin Russwin locks are designed with quality
components to provide high security, performance and durability.
3) Specifications / Features
Hardware Specifications
• Latch – Stainless steel, ½” (13mm) throw
Optional: ¾” (19mm) throw deadlocking fire
latch for pairs of doors
• Deadlocking latch prevents manipulation when
door closed
• Door Thickness – Standard 1-3/4” (44mm) to
2” (50mm)
Optional 2” (50mm) to 2-1/4” (57mm)
• Outside lever controlled by reader or key
retracts latch
• Inside Lever produces REX (request to
exit) signal
• Complete monitoring of door - DPS
(External Door Position Switch supplied)
• May be used for both indoor and
exterior applications.
• UL fire listed
A weather-protective gasket is required for exterior applications.
Electronic Specifications
•
Input Power: DC 9V, 1.5A (6 AA alkaline batteries)
•
Optional hard-power 12VDC to 24VDC
•
HID® multiCLASS SE® technology offers support
for the following credentials:
• High Frequency (13.56 MHz):
• HID iCLASS®
• HID iCLASS SE® (SIO-enabled)
• HID iCLASS® Seos™
• HID MIFARE® SE
• HID DESfire® EV1 SE
• MIFARE Classic
• DESfire EV1
• Low Frequency (125 kHz):
• HID Prox®
• NFC-enabled Mobile Phones
•
Uses low-rate wireless personal area networks
(IEEE 802.14.4)
•
Multiple time zone and holiday access scheduling
•
First-in unlock or automatic unlock configuration,
based on specified time schedule
•
Uses AES 128-bit wireless encryption*
•
Privacy button
*For specific security information, please contact
your local ASSA ABLOY Door Security Solutions
sales consultant or call 800-810-WIRE.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
4) Product Illustration
Reader Module
ITEM
PART NUMBER/ORDER STRING
DESCRIPTION
COLOR/TRIM
QTY
IN-100-EM01CL33134-IP-B
®
HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
Black
IN-100-EM01CL33134-IP-W
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
White
IN-100-EM01CL33134-IP-MB-[finish]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
Black with metal trim
IN-100-EM01CL33134-IP-MW-[finish]*
HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
White with metal trim
IN-100-EM01CL33134-IPS-B
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
Black
IN-100-EM01CL33134-IPS-W
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
White
IN-100-EM01CL33134-IPS-MB-[finish]*
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
Black with metal trim
IN-100-EM01CL33134-IPS-MW-[finish]*
All credentials supported by the IP option plus MIFARE Classic and DESfire EV1
White with metal trim
®
®
®
820F558
Inside Mounting Kit (mounting plate & hardware)
820F549
IN100 Controller
N/A
AA battery
820F489
Inside Escutcheon
Black
820F499
Inside Escutcheon
White
820F525 FIN*
Inside Escutcheon
Black with metal trim
820F535 FIN*
Inside Escutcheon
White with metal trim
FM356
Field prep template (not shown)
T31203
Door manufacturers template (not shown)
--
FM404
Instructions (this manual)
* Specify finish
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
4) Product Illustration (Continued)
Tools Required:
• Phillips Screw Driver #2, #3
• Flat Blade Screw Driver (Standard size)
• 1/8” Security Allen Wrench (supplied)
1*
785F628
CL33134 Cylindrical lock with fixed core cylinder
785F638
CL33134 Cylindrical lock with removable core cylinder
785F488
Inside Spring Cassette - IN100 REX (1-3/4” - 2” Door)
785F498
Inside Spring Cassette - IN100 REX (2-1/4” Door)
783F208
Outside Spring Cassette
820F609
DPS (Door Position Switch) Kit
*The IN100 CL33134 cylindrical lock supports Escape Return functionality.
For parts not listed, refer to CL3300 Parts and Service Manual.
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
5) Installation Instructions
1.
Verify Hand and Bevel of door
Illustrations shown are as viewed from the outside or secure side of opening.
Left Hand
Hinges Left.
Open Inward.
“LH”
2.
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
Right Hand
Hinges Right.
Open Inward.
“RH”
Fig. 1
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
Door Preparation
Prep door according to supplied door marker (FM356). For door manufacturer templates
visit www.corbinrusswin.com and reference template # T31203.
Wood Door
shown
Outside Face
of Door
Raceway for Optional
Remote Power
Inside Face
of Door
Raceway for Optional
Remote Power
Through-bolt
Hole
Through-bolt Hole
External DPS
Hole
Raceway for
Lockbody
Harness
Cylindrical
Pocket and
Pre-drilled
Tap Holes
Through-bolt Hole
Raceway for
Lockbody
Harness
Through-bolt
Hole
Lever Handle
Hole
Fig. 2
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Cable Hole
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
3.
Install Door Position Switch (DPS)
a. Insert DPS into the raceway on the latch edge of the door.
b. Push wires through raceway toward lock prep.
c. Push DPS firmly into place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
d. Install magnet into door frame. Push firmly into place by hand.
See instruction A7983A.
CAUTION: if DPS is not installed or is installed
improperly, door status monitoring features will
not function.
Fig. 3
4.
Install Latch Bolt
Install latch bolt with beveled bolt facing the strike
using two #8 x 3/4” combination screws (Fig. 4):
Fig. 4
5.
Install Strike Plate
Install Strike Plate using two #12 x 1” combination
screws (Fig. 5):
Optional Strike Box
Fig. 5
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
6.
Install Lock Body
a. Feed lock body and wire through 2-1/8” diameter hole from outside of door (Fig. 6a).
Engage latch with lock body. Latch ears must slide into housing as shown (Fig. 6b).
b. Connect 4-pin connector from lock body to 4-pin on
cassette (Fig. 6c).
Outside Face of Door
Fig. 6b
Fig. 6a
c. Temporarily install top throughbolt to hold chassis in door (Fig. 6c).
Important: Door must remain open during installation.
Use door stop.
Inside Face of Door
d. Connect REX wire from I/S cassette to
lockbody harness.
Spring Cassette
Fig. 6c
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
7.
Install Inside Spring Cassette Lock
a. Feed harness wires and ground wire up through raceway (Fig. 7a).
b. Remove screw from previous step.
c. Slide on cassette and secure with (2) screws (Fig. 7b).
Remove Screw
Fig. 7a
Fig. 7b
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Spring Cassette
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
8.
Installation and Removal of Lever and Standard Cylinder
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
10
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
9.
Install Outside (Reader) Escutcheon and Inside Mounting Plate
a. Orient the reader so the LED lens is at the top.
b. Feed reader harness through door (from outside to inside).
c. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Hold the reader flush against door while ensuring proper alignment.
Outside Face of Door
LED
Reader Assembly
with Harness
Fig. 9a
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
11
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
d. Feed the reader harness and DPS connectors through the inside mounting assembly
(and gasket if required*). See Figure 9b.
IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 9b, c) - it will damage wires and
the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9c).
e. Tuck excess cable into wire hole on inside of door.
f. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
inside of the door while ensuring proper alignment as you secure the reader (Fig. 9b).
Inside of Door
NOTE: Cable lengths exaggerated for illustrative purposes.
Gasket*
Mounting Plate
Through bolt
DPS
Reader
Harness
Ground
Lug
Lock body
Harness
Through bolt
Fig. 9c
Fig. 9b
g. Secure ground lug with #6-32 machine screw (Fig. 9c).
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors through holes
as indicated (Fig. 9b).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
12
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
10.
Installation of Connectors
CAUTION - Do not touch or allow debris to enter connector contacts.
DPS (4-pin)
9-24VDC
Power*
Secure the following connectors to their respective terminals (Fig. 10D):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
*NOTE: Optional 2-pin external 9-24VDC power connector.
Ground
Lug
IMPORTANT: Do not run wires through bottom hole in plate - it will
damage wires and the controller connector.
Route wires around flange, do not route wires through
the flange hole (Fig. 10B, D).
Fig. 10D
C. When all connections have been made, tuck excess cable
into wire hole on inside of door.
Lock
Body
(10-pin)
Secure Mounting Plate
D. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 10E).
Fully
tighten
E. Secure the 24-pin card reader connector (Fig. 10F).
Reader
(24-pin)
Fig. 10E
Board-to-Board
Connector
Fig. 10F
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
13
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
11.
Installation of Inside Component Assembly
CAUTION: To avoid possible damage to board-to-board connectors,
care should be taken when securing controller to mounting
plate. If there is resistance when securing, detach controller
to determine cause before re-attaching controller.
a. Insert top tabs of controller into slots on mounting plate (Fig. 11).
b. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller
toward door until tab on bottom snaps securely into place on mounting plate.
Inside Face of
Door
Fig. 11
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
14
IN100 Cylindrical Lock
5) Installation Instructions (Continued)
12.
Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly (Fig. 12).
2. After batteries are installed, there is a slight delay; then red and
green flash, audible “beep” and lock motor will cycle.
Fig. 12
13.
Inside Cover Installation
Inside
Cover
a. Assemble cover by hooking top edge on inside
mounting plate.
b. Carefully press bottom of cover toward door without
pinching or damaging wires.
c. Secure cover utilizing security allen wrench (provided).
Security Allen
Screw
Fig. 13
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
15
IN100 Cylindrical Lock
6) Operational Check
When lock is fully installed, perform the following steps:
a. Insert key into cylinder and rotate (Fig. 14a).
b. There should be no friction against lock case, wire harness or
any other obstructions.
c. Check that the key retracts the latch.
d. The key should rotate freely.
e. Try the inside lever; ensure it retracts latch.
f. Present a valid credential* (Fig. 14b) to unlock outside lever; turn
lever handle to ensure latch retracts.
Fig. 14a
Note: The credential should approach the inscription
on the reader as indicated (Fig. 13b) to ensure
that the credential is read properly.
Do not wave credential.
Fig. 14b
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
16
IN100 Cylindrical Lock
7) LED Indications
The communication hub has a single LED. It supports an optical scheme of red, green and yellow.
The indication scheme is described by the figures below:
Communication Hub LED indications
Figure 1.
Communication hub normal
operation LED indication
2 sec.
Online
Green
Aperio® lock
offline
Green + one
red flash
Green + two red flashes
EAC offline
Aperio® lock and
EAC offline
Green + three
red flashes
UHF
communication
Yellow + off,
fast flash
Some special LED indication schemes* are
used during lock maintenance actions:
2 sec.
Figure 2.
Communication hub maintenance
LED indication
Pairing active
Yellow + green
Ethernet LED indication
The LED on the AH40 communication hub* indicates both the status of
the Ethernet link level and ethernet communication:
2 sec.
Figure 3.
AH40 Communication hub
Ethernet LED indication
Ethernet
link connected
Green
Ethernet
communication
Green +
off fast flash
*For more information, refer to Aperio Online Quick Installation Guide
(Document No: ST-001322-PF Date: 2015-12-23)
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
17
IN100 Cylindrical Lock
Lock LED indications
The lock has three LEDs. They support an optical scheme of red, yellow and green.
The indication scheme is described by the figures below:
Figure 4. Lock normal operation LED
indication
Card + PIN access
(configurable)
EAC response
time
Card access
(configurable)
Enter PIN
One yellow flash after card, two
flashes before PIN (.125 second)
One yellow flash (.25 second)
One green flash
(1 sec.)
Access granted,
EAC offline or online
One red flash
(1 sec.)
Access denied,
EAC online
Force closed in remote
open/office mode
Five yellow flashes and
one red flash (.25 second)
Busy blink, com hub
busy with other locks
Continuous yellow flashes
(.25 seconds every second)
Three red flashes
(.5 second each)
Access denied,
EAC offline
Lock mechanism is
blocked when closing 1)
Continuous red flashes
(.125 seconds every 1 sec.)
Error in lock,
maintenance required
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Ten red flashes (.125 sec. each)
repeated every 10 sec.
Tamper
Time to replace
the battery
Continuous yellow flashes
(.25 seconds every 5 sec.)
Battery reached end
of life, lock disabled
Continuous red flashes (.25
seconds every 5 sec.)
Five yellow flashes
(.25 second each)
V3 USB cable detection
action occurred
1) When the lock mechanism is blocked (lock jammed) the lever must be turned to
release the lock mechanism.
Some special LED indication schemes are used during lock maintenance actions:
Figure 5. Lock hub normal
operation LED indication
Enter configuration
mode
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
18
Five yellow flashes
(.125 second each)
IN100 Cylindrical Lock
Lock Self-Test LED indication
After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using
a series of red and green LED flashes as described by the figures below.
LED indication after power up/replacement of the battery
8.3.1
Battery not fully charged
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
right voltage or a backward battery has been installed; battery not fully charged; energy counter
not reset or no Power on self-test done.
Error in lock,
maintenance required
8.3.2
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can’t close)
Test pass
1 red (1s) + 1 green (1s), Power on self-test passed, see table below.
Figure 6. Lock POST LED
indication
8.3.3
One red, one green flash
(1 second)
POST Successful
Test fail
1 red (1s) + 3 blinks (.5 sec, green or red), at least one test failed (red), see table below.
If a fatal error is detected the lock will enter an Error state and continuously indicating fatal error and will
not read cards nor unlock.
1 sec
0.5 sec
0.5 sec
0.5 sec
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
FATAL ERROR
Tests core functionality - MCUs, memory and internal
communication, etc.
CABLE ERROR
Tests communication between the different
parts in the system, i.e. different boards
connected with a wire.
MECHANICAL ERROR Test related to moving parts of the lock.
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
19
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:06:28 15:08:43-04:00
Metadata Date                   : 2016:06:28 15:08:50-04:00
Modify Date                     : 2016:06:28 15:08:50-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:05473d82-b765-455d-930e-cf888c007399
Original Document ID            : adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985
Document ID                     : xmp.id:ff80a5bb-650d-7c4e-bd81-c43b6f75dbec
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:ff877adf-ea64-794b-97dd-bb99971f8cc6
Derived From Document ID        : xmp.did:ff877adf-ea64-794b-97dd-bb99971f8cc6
Derived From Original Document ID: adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:06:28 15:08:43-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 20
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools