ASSALOY SCYMCA1 Aperio V3 iN100 RF Module User Manual FM404 IN100 Bored Instr
ASSA ABLOY Inc. Aperio V3 iN100 RF Module FM404 IN100 Bored Instr
ASSALOY >
Contents
User Manual - FM404 IN100 Bored Instr
Cylindrical Lockset IN100 WiFi Installation Instructions FM404 07/16 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security. For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473) Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock Table of Contents 1) Warning.................................................................................2 2) General Description..............................................................3 3) Specifications / Features.....................................................3 4) Product Illustration..............................................................4 5) Installation Instructions.......................................................6 6) Operational Check............................................................. 16 7) LED Indications..................................................................17 1) Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced technician for help The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components: • Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door. • Leave components (reader and controller) protected in their respective anti-static bags until ready for installation • Do not touch pins, leads or solder connections on the circuit boards Copyright © 2016 Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 2) General Description The Corbin Russwin® IN100 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The IN100 utilizes HID® 125 kHz prox or 13.56 MHz iCLASS® smart card technology, and all technology features are supported by the physical security of Corbin Russwin ANSI/BHMA Grade 1 hardware. This product is operated by six (6) “AA” alkaline batteries. Corbin Russwin locks are designed with quality components to provide high security, performance and durability. 3) Specifications / Features Hardware Specifications • Latch – Stainless steel, ½” (13mm) throw Optional: ¾” (19mm) throw deadlocking fire latch for pairs of doors • Deadlocking latch prevents manipulation when door closed • Door Thickness – Standard 1-3/4” (44mm) to 2” (50mm) Optional 2” (50mm) to 2-1/4” (57mm) • Outside lever controlled by reader or key retracts latch • Inside Lever produces REX (request to exit) signal • Complete monitoring of door - DPS (External Door Position Switch supplied) • May be used for both indoor and exterior applications. • UL fire listed A weather-protective gasket is required for exterior applications. Electronic Specifications • Input Power: DC 9V, 1.5A (6 AA alkaline batteries) • Optional hard-power 12VDC to 24VDC • HID® multiCLASS SE® technology offers support for the following credentials: • High Frequency (13.56 MHz): • HID iCLASS® • HID iCLASS SE® (SIO-enabled) • HID iCLASS® Seos™ • HID MIFARE® SE • HID DESfire® EV1 SE • MIFARE Classic • DESfire EV1 • Low Frequency (125 kHz): • HID Prox® • NFC-enabled Mobile Phones • Uses low-rate wireless personal area networks (IEEE 802.14.4) • Multiple time zone and holiday access scheduling • First-in unlock or automatic unlock configuration, based on specified time schedule • Uses AES 128-bit wireless encryption* • Privacy button *For specific security information, please contact your local ASSA ABLOY Door Security Solutions sales consultant or call 800-810-WIRE. To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 4) Product Illustration Reader Module ITEM PART NUMBER/ORDER STRING DESCRIPTION COLOR/TRIM QTY IN-100-EM01CL33134-IP-B ® HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones Black IN-100-EM01CL33134-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones White IN-100-EM01CL33134-IP-MB-[finish]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones Black with metal trim IN-100-EM01CL33134-IP-MW-[finish]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones White with metal trim IN-100-EM01CL33134-IPS-B All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black IN-100-EM01CL33134-IPS-W All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 White IN-100-EM01CL33134-IPS-MB-[finish]* All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black with metal trim IN-100-EM01CL33134-IPS-MW-[finish]* All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 White with metal trim ® ® ® 820F558 Inside Mounting Kit (mounting plate & hardware) 820F549 IN100 Controller N/A AA battery 820F489 Inside Escutcheon Black 820F499 Inside Escutcheon White 820F525 FIN* Inside Escutcheon Black with metal trim 820F535 FIN* Inside Escutcheon White with metal trim FM356 Field prep template (not shown) T31203 Door manufacturers template (not shown) -- FM404 Instructions (this manual) * Specify finish Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 4) Product Illustration (Continued) Tools Required: • Phillips Screw Driver #2, #3 • Flat Blade Screw Driver (Standard size) • 1/8” Security Allen Wrench (supplied) 1* 785F628 CL33134 Cylindrical lock with fixed core cylinder 785F638 CL33134 Cylindrical lock with removable core cylinder 785F488 Inside Spring Cassette - IN100 REX (1-3/4” - 2” Door) 785F498 Inside Spring Cassette - IN100 REX (2-1/4” Door) 783F208 Outside Spring Cassette 820F609 DPS (Door Position Switch) Kit *The IN100 CL33134 cylindrical lock supports Escape Return functionality. For parts not listed, refer to CL3300 Parts and Service Manual. Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 5) Installation Instructions 1. Verify Hand and Bevel of door Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Hinges Left. Open Inward. “LH” 2. Left Hand Reverse Bevel Hinges Left. Open Outward “LHRB” Right Hand Hinges Right. Open Inward. “RH” Fig. 1 Right Hand Reverse Bevel Hinges Right. Open Outward “RHRB” Door Preparation Prep door according to supplied door marker (FM356). For door manufacturer templates visit www.corbinrusswin.com and reference template # T31203. Wood Door shown Outside Face of Door Raceway for Optional Remote Power Inside Face of Door Raceway for Optional Remote Power Through-bolt Hole Through-bolt Hole External DPS Hole Raceway for Lockbody Harness Cylindrical Pocket and Pre-drilled Tap Holes Through-bolt Hole Raceway for Lockbody Harness Through-bolt Hole Lever Handle Hole Fig. 2 Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Cable Hole IN100 Cylindrical Lock 5) Installation Instructions (Continued) 3. Install Door Position Switch (DPS) a. Insert DPS into the raceway on the latch edge of the door. b. Push wires through raceway toward lock prep. c. Push DPS firmly into place by hand. Note: DO NOT TAP SWITCH WITH ANY TOOL. d. Install magnet into door frame. Push firmly into place by hand. See instruction A7983A. CAUTION: if DPS is not installed or is installed improperly, door status monitoring features will not function. Fig. 3 4. Install Latch Bolt Install latch bolt with beveled bolt facing the strike using two #8 x 3/4” combination screws (Fig. 4): Fig. 4 5. Install Strike Plate Install Strike Plate using two #12 x 1” combination screws (Fig. 5): Optional Strike Box Fig. 5 Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 5) Installation Instructions (Continued) 6. Install Lock Body a. Feed lock body and wire through 2-1/8” diameter hole from outside of door (Fig. 6a). Engage latch with lock body. Latch ears must slide into housing as shown (Fig. 6b). b. Connect 4-pin connector from lock body to 4-pin on cassette (Fig. 6c). Outside Face of Door Fig. 6b Fig. 6a c. Temporarily install top throughbolt to hold chassis in door (Fig. 6c). Important: Door must remain open during installation. Use door stop. Inside Face of Door d. Connect REX wire from I/S cassette to lockbody harness. Spring Cassette Fig. 6c Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. IN100 Cylindrical Lock 5) Installation Instructions (Continued) 7. Install Inside Spring Cassette Lock a. Feed harness wires and ground wire up through raceway (Fig. 7a). b. Remove screw from previous step. c. Slide on cassette and secure with (2) screws (Fig. 7b). Remove Screw Fig. 7a Fig. 7b Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Spring Cassette IN100 Cylindrical Lock 5) Installation Instructions (Continued) 8. Installation and Removal of Lever and Standard Cylinder Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 10 IN100 Cylindrical Lock 5) Installation Instructions (Continued) 9. Install Outside (Reader) Escutcheon and Inside Mounting Plate a. Orient the reader so the LED lens is at the top. b. Feed reader harness through door (from outside to inside). c. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader flush against door while ensuring proper alignment. Outside Face of Door LED Reader Assembly with Harness Fig. 9a Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 11 IN100 Cylindrical Lock 5) Installation Instructions (Continued) d. Feed the reader harness and DPS connectors through the inside mounting assembly (and gasket if required*). See Figure 9b. IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 9b, c) - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9c). e. Tuck excess cable into wire hole on inside of door. f. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the inside of the door while ensuring proper alignment as you secure the reader (Fig. 9b). Inside of Door NOTE: Cable lengths exaggerated for illustrative purposes. Gasket* Mounting Plate Through bolt DPS Reader Harness Ground Lug Lock body Harness Through bolt Fig. 9c Fig. 9b g. Secure ground lug with #6-32 machine screw (Fig. 9c). *Gasket is required for outdoor installations. If installing with gasket; separate gasket from mounting plate to feed cables/connectors through holes as indicated (Fig. 9b). Once cables/connectors are fed through, reattach gasket to mounting plate. Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 12 IN100 Cylindrical Lock 5) Installation Instructions (Continued) 10. Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. DPS (4-pin) 9-24VDC Power* Secure the following connectors to their respective terminals (Fig. 10D): A. Secure the 4-pin DPS connector. B. Secure the 10-pin lock body assembly connector. *NOTE: Optional 2-pin external 9-24VDC power connector. Ground Lug IMPORTANT: Do not run wires through bottom hole in plate - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 10B, D). Fig. 10D C. When all connections have been made, tuck excess cable into wire hole on inside of door. Lock Body (10-pin) Secure Mounting Plate D. Secure the mounting assembly while ensuring proper alignment of outside reader and tighten the (2) through-bolts on the inside of the door to secure the reader (Fig. 10E). Fully tighten E. Secure the 24-pin card reader connector (Fig. 10F). Reader (24-pin) Fig. 10E Board-to-Board Connector Fig. 10F Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 13 IN100 Cylindrical Lock 5) Installation Instructions (Continued) 11. Installation of Inside Component Assembly CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate. If there is resistance when securing, detach controller to determine cause before re-attaching controller. a. Insert top tabs of controller into slots on mounting plate (Fig. 11). b. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate. Inside Face of Door Fig. 11 Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 14 IN100 Cylindrical Lock 5) Installation Instructions (Continued) 12. Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly (Fig. 12). 2. After batteries are installed, there is a slight delay; then red and green flash, audible “beep” and lock motor will cycle. Fig. 12 13. Inside Cover Installation Inside Cover a. Assemble cover by hooking top edge on inside mounting plate. b. Carefully press bottom of cover toward door without pinching or damaging wires. c. Secure cover utilizing security allen wrench (provided). Security Allen Screw Fig. 13 Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 15 IN100 Cylindrical Lock 6) Operational Check When lock is fully installed, perform the following steps: a. Insert key into cylinder and rotate (Fig. 14a). b. There should be no friction against lock case, wire harness or any other obstructions. c. Check that the key retracts the latch. d. The key should rotate freely. e. Try the inside lever; ensure it retracts latch. f. Present a valid credential* (Fig. 14b) to unlock outside lever; turn lever handle to ensure latch retracts. Fig. 14a Note: The credential should approach the inscription on the reader as indicated (Fig. 13b) to ensure that the credential is read properly. Do not wave credential. Fig. 14b Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 16 IN100 Cylindrical Lock 7) LED Indications The communication hub has a single LED. It supports an optical scheme of red, green and yellow. The indication scheme is described by the figures below: Communication Hub LED indications Figure 1. Communication hub normal operation LED indication 2 sec. Online Green Aperio® lock offline Green + one red flash Green + two red flashes EAC offline Aperio® lock and EAC offline Green + three red flashes UHF communication Yellow + off, fast flash Some special LED indication schemes* are used during lock maintenance actions: 2 sec. Figure 2. Communication hub maintenance LED indication Pairing active Yellow + green Ethernet LED indication The LED on the AH40 communication hub* indicates both the status of the Ethernet link level and ethernet communication: 2 sec. Figure 3. AH40 Communication hub Ethernet LED indication Ethernet link connected Green Ethernet communication Green + off fast flash *For more information, refer to Aperio Online Quick Installation Guide (Document No: ST-001322-PF Date: 2015-12-23) Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 17 IN100 Cylindrical Lock Lock LED indications The lock has three LEDs. They support an optical scheme of red, yellow and green. The indication scheme is described by the figures below: Figure 4. Lock normal operation LED indication Card + PIN access (configurable) EAC response time Card access (configurable) Enter PIN One yellow flash after card, two flashes before PIN (.125 second) One yellow flash (.25 second) One green flash (1 sec.) Access granted, EAC offline or online One red flash (1 sec.) Access denied, EAC online Force closed in remote open/office mode Five yellow flashes and one red flash (.25 second) Busy blink, com hub busy with other locks Continuous yellow flashes (.25 seconds every second) Three red flashes (.5 second each) Access denied, EAC offline Lock mechanism is blocked when closing 1) Continuous red flashes (.125 seconds every 1 sec.) Error in lock, maintenance required Ten red flashes (.125 sec. each) (Repeated every 10 sec. if lock can’t close) Ten red flashes (.125 sec. each) repeated every 10 sec. Tamper Time to replace the battery Continuous yellow flashes (.25 seconds every 5 sec.) Battery reached end of life, lock disabled Continuous red flashes (.25 seconds every 5 sec.) Five yellow flashes (.25 second each) V3 USB cable detection action occurred 1) When the lock mechanism is blocked (lock jammed) the lever must be turned to release the lock mechanism. Some special LED indication schemes are used during lock maintenance actions: Figure 5. Lock hub normal operation LED indication Enter configuration mode Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 18 Five yellow flashes (.125 second each) IN100 Cylindrical Lock Lock Self-Test LED indication After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as described by the figures below. LED indication after power up/replacement of the battery 8.3.1 Battery not fully charged Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the right voltage or a backward battery has been installed; battery not fully charged; energy counter not reset or no Power on self-test done. Error in lock, maintenance required 8.3.2 Ten red flashes (.125 sec. each) (Repeated every 10 sec. if lock can’t close) Test pass 1 red (1s) + 1 green (1s), Power on self-test passed, see table below. Figure 6. Lock POST LED indication 8.3.3 One red, one green flash (1 second) POST Successful Test fail 1 red (1s) + 3 blinks (.5 sec, green or red), at least one test failed (red), see table below. If a fatal error is detected the lock will enter an Error state and continuously indicating fatal error and will not read cards nor unlock. 1 sec 0.5 sec 0.5 sec 0.5 sec FATAL ERROR CABLE ERROR MECHANICAL ERROR FATAL ERROR Tests core functionality - MCUs, memory and internal communication, etc. CABLE ERROR Tests communication between the different parts in the system, i.e. different boards connected with a wire. MECHANICAL ERROR Test related to moving parts of the lock. Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 19 Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00 Create Date : 2016:06:28 15:08:43-04:00 Metadata Date : 2016:06:28 15:08:50-04:00 Modify Date : 2016:06:28 15:08:50-04:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:05473d82-b765-455d-930e-cf888c007399 Original Document ID : adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Document ID : xmp.id:ff80a5bb-650d-7c4e-bd81-c43b6f75dbec Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:ff877adf-ea64-794b-97dd-bb99971f8cc6 Derived From Document ID : xmp.did:ff877adf-ea64-794b-97dd-bb99971f8cc6 Derived From Original Document ID: adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2016:06:28 15:08:43-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 20 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools