AVITA BPW-15XX Arm Type Bluetooth Blood Pressure Monitor User Manual 72 B63MN 151

AVITA Corporation Arm Type Bluetooth Blood Pressure Monitor 72 B63MN 151

Manual

Download: AVITA BPW-15XX Arm Type Bluetooth Blood Pressure Monitor User Manual 72 B63MN 151
Mirror Download [FCC.gov]AVITA BPW-15XX Arm Type Bluetooth Blood Pressure Monitor User Manual 72 B63MN 151
Document ID2687389
Application IDbpCR/QdvJYdPxWtRhHFJQQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize79.05kB (988127 bits)
Date Submitted2015-07-21 00:00:00
Date Available2015-07-22 00:00:00
Creation Date2015-07-01 11:27:29
Producing SoftwareCorel PDF Engine Version 14.0.0.701
Document Lastmod2015-07-01 11:27:29
Document Title72-B63MN-151 無鬧鈴
Document CreatorCorelDRAW
Document Author: AS70-賴琪珍

Arm Type Bluetooth Blood Pressure Monitor
Model No.: BPM63ZB
INSTRUCTION MANUAL
PLEASE READ THIS INSTRUCTION MANUAL COMPLETELY
BEFORE OPERATING THIS UNIT.
Index
Intended Use
Important Information Before Use
Product Identification
Description of LCD Display
Battery Installation
Setting the Date and Time
Placement of the Pressure Sleeve
Measurement of Pulse Rate and Blood Pressure
Irregular Heartbeat Detector
10
World Health Organization (WHO)
10
Memory Function
11
Operating the Bluetooth function
12
Troubleshooting
13
Error Codes
13
Care and Maintenance
14
Applied Standards
14
Technical Specification
14
FCC Statement
15
EMC Tables
16
Intended Use
BPM63ZB Series Blood Pressure Monitor applies the Oscillometric
method to measure human systolic / diastolic blood pressure and heart
rate.All values are shown on the LCD monitor.
This device is designed only for adults.
Important Information Before Use
1. Blood pressure measurements should only be interpreted by a
physician or a trained health care professional who is familiar with
your medical history. Through regular use of this device and
recording of your measurements, you can keep your physician
informed of the changes in your blood pressure.
2. Perform your measurement in a quiet place. You should be seated in
a relaxed position.
3. Avoid smoking, eating, taking medication, alcohol consumption or
physical activity 30 minutes prior to taking a reading. If you are
exhibiting signs of stress, avoid taking your measurement until the
feeling subsides.
4. Rest 15 minutes prior to taking a reading.
5. Remove any constrictive clothing or jewelry that may interfere with
the cuff placement.
6. Keep the monitor stable during measurement to achieve an accurate
reading. Remain still; do not talk during the measurement.
7. Record your daily blood pressure and pulse readings on a chart.
8. Take your readings at the same time, each day or as recommended
by your physician to get an accurate indication of change in your true
blood pressure.
9. Wait a minimum of 15 minutes between readings to allow for the
blood vessels to return to normal. The wait time may vary depending
on your individual physiological characteristics.
10. Although such cases are rare, for those with an extremely weak
pulse or irregular pulse, errors may result which prevent proper
measurement. If abnormal variations are noticed, consult with your
physician or trained healthcare professional.
11. This device is intended for adult use. While taking a measurement,
you can stop the inflation or deflation process of the cuff at any time
by pressing the POWER button.
Under any circumstances, the measurement taking result is ONLY
for reference.
Any further medical action should follow the advice of doctors.
Product Identification
LCD Display
Air Connector Plug
(connects to Air socket)
Air Socket
(insert Air
connector
plug here)
Arm Cuff
Date and Time
Set Button
MEMORY
Recall
Button
INDEX
START/POWER
Button (on/off)
Air tube
Description of LCD Display
Date
Time
Systolic
Pressure
Inflation/Deflation Symbol
Irregular Heart Beat Symbol
Diastolic
Pressure
Low Battery Symbol
Average Measurement Symbol
Memory Symbol
Pulse
Rate
Memory Sets
WHO Indicator
Heartbeat
Symbol
Battery Installation
Low battery warning:
It is necessary to replace the batteries when the Low
Battery symbol “
” appears on the display, or when
the display does not turn on after the POWER button is
pressed.
Replacing the Battery:
1. Press down on latch and lift the cover on the bottom of the monitor.
2. Insert or replace 4 x 1.5 V AA batteries into the battery compartment,
ensuring to match the indicated polarity symbols. Always use new
batteries.
3. Replace the battery cover.
NOTE: Battery-operated
1. Please properly dispose of the batteries away from small children
and heat.
2. It is recommended to remove the batteries if the unit will not be used
for an extended period of time.
3. Batteries must be disposed of in accordance with local
environmental and institutional policies.
Setting the Date and Time
It is necessary to set the date and time for the unit every time
batteries are initially installed or replaced.
1. While in power off mode, press the “Date and Time Set” button to
enter Date and Time setting procedure and the Year value will begin
to flash.
2. Press the “MEMORY Recall” button to advance the display to the
desired year, press “POWER” button to confirm the year.
3. Next, the month will blink. Repeat step 2 to set the month and date,
then hours, then minutes.
4. After setting the minutes, the unit will automatically exit out of the
date/time setting mode and briefly show the word OFF before
shutting down.
Press the
“Date and Time Set”
button
Year
Press the
“POWER”
button
Press the
“POWER”
button
Date
Month
Press the
“POWER”
button
Press the
“POWER”
button
Hour
Minute
Press the
“POWER”
button
Placement of the Pressure Sleeve
It is important to avoid smoking, eating, taking medication, alcohol
consumption or physical activity 30 minutes prior to taking a reading. If
for any reason you are unable to or should not use your left arm, please
modify the instructions for cuff application to your right arm. Your
physician can help you identify which arm is best for you to take
measurements from.
1. Remove any constrictive clothing or jewelry that
may interfere with cuff placement.
2. Be seated at a table or desk with your feet flat on
the floor.
3. The cuff should not be plugged into the monitor until after the cuff is
applied to your arm.
Note:
Blood pressure naturally varies from one arm to the other;
therefore, measure your blood pressure on the same arm to
ensure comparability of the two readings.
4. Position the cuff on a solid surface with the tubing facing up and
away from you. The metal ring/bar on the cuff should be to the left of
the tubing.
5. Open the cuff by pulling or rolling the bottom of the
cuff to the right. This should open the cuff without
fully unrolling it, creating a cylinder. Do not fully
unwrap or unroll the cuff.
6. Insert your left arm into the created cuff
cylinder. Position the ( ) mark over the
main artery on the inside of your arm.
Main Artery
7. The bottom edge of the cuff should be
positioned approximately one inch above
the elbow joint.
Placement of the Pressure Sleeve
8. Reaching underneath your left arm with
your right hand, pull the end of the cuff
towards your body to tighten the cuff.
Wrap and secure the cuff, making sure
that the ( ) mark remains in place as
shown.
9. The cuff should fit comfortably, yet snugly around your arm. You
should be able to insert one finger easily between your arm and the
cuff.
10.The cuff size is suitable for use when the vertical ‘index’ mark is
within the horizontal OK range. A different size cuff is needed if the
‘index’ mark is outside the OK range.
Note:
If you are not comfortable with applying your cuff, please
seek the assistance of another member of your household or
work with your physician to practice the cuff application.
Incorrectly applied cuffs may result in inaccurate readings.
Measurement of Pulse Rate and Blood Pressure
Please read the preceding portions of this manual prior to taking your
first reading.
1. Position the monitor on a flat, stable surface with the
digital display in view.
2. Insert the cuff tubing connector into the port on the
left side of your monitor.
3. Rest your elbow on a solid surface with your
palm facing upward. Elevate your arm so that
the cuff is at the same level as your heart.
Relax your left hand.
4. Press the POWER button. This will turn the power on.
5. After the self-test, the values for the last reading will
appear on the display.
6. The blood pressure monitor start to measure.
7. The cuff will automatically begin to inflate, with the
display showing the increasing pressure in the cuff. As
the pressure increases, an arrow pointing up will appear
on the display.
8. When the inflation has reached optimum level, the
display will begin to show the decreasing pressure; the
screen will display an arrow pointing down while you feel
the pressure of the cuff decrease.
Measurement of Pulse Rate and Blood Pressure
9. To detect the heartbeat, the heartbeat symbol will appear
and continuous flashes on the LCD display.
10.Your blood pressure measurement and pulse will
display simultaneously on the screen.
11.The Hypertension Indicator will indicate your reading
range on the display separately.
12. Your reading will be automatically stored in "MEMORY Recall"
Button.
13. Select POWER to turn the unit off and conserve energy and battery
life. The unit will automatically shut-off approximately 2 minutes.
Irregular Heartbeat Detector
Your digital blood pressure monitor features an Irregular
Heartbeat Detector. This feature allows users to
accurately monitor blood pressure even if an irregular
heartbeat should occur. When an irregular heartbeat is
detected, the “
” icon will appear on the display.
Note:
Please consult with your physician or trained healthcare
professional for further information regarding an irregular
heartbeat and if this symbol appears frequently.
World Health Organization (WHO)
This unit features our unique Hypertension Indicator. The World Health
Organization has established globally accepted standards for the
assessment of high or low blood pressure readings. The below chart
should be considered only as a guideline, always consult with your
physician or health care professional to interpret your individual
results.
Diastolic Blood Pressure
Severe Hypertension (Grade 3)
110
Moderate Hypertension (Grade 2)
100
Mild Hypertension (Grade 1)
90
85
80
High-Normal
Normal
Optimal
120
130
140
160
180
Systolic Blood Pressure
Hypertension Indicator
10
Memory Function
Recalling Measurements in Memory:
You can recall up to 60 measurements per memory bank, plus an
average of last 3 currently stored measurements in memory to share
with your physician or trained healthcare professional.
1. Press and release the "MEMORY Recall" Button. The unit will first
display the average of last 3 currently stored measurements.
2. Continue to press the "MEMORY Recall" Button to successively view
the next previously stored measurements. Measurements will
appear on the display from most current to oldest; the memory
number will appear on the lower left corner.
Press the
“MEMORY Recall”
button
3. All results for a given measurement will display, including
measurement results, pulse rate, Hypertension Indicator, Irregular
Heartbeat alert, and date/time stamp.
4. The memory bank stores up to 60 readings; when the number of
readings exceeds 60, the oldest data will be replaced with the new
record.
5. Press the Power button to turn the monitor OFF at any time during
review of the stored measurements.
Clearing Measurements from Memory:
From power display off, press and hold down the "MEMORY
Recall" Button until the display shows CLr. This indicates that
all measurements have been erased.
11
Operating the Bluetooth function
BPM63ZB is through the Bluetooth technology (BLE4.0) to transfer the
related information of your blood pressure measurement. Please
determine your device (Mobile Phone or Computer) has BLE4.0
equipped to support BPM63ZB operation. Currently, BPM63ZB can
support the iOS and Android operating systems.
You can also send results in memory zone as following step.
1. Press “Memory recall button” of blood pressure
monitor to enter memory mode. The symbol “AVG” and
“M” will appear on the display and the number of memory
index is “00”.
2. Turn on the Bluetooth function of device to search the
blood pressure monitor. Then the blood pressure
monitor will be searched and connected the Bluetooth
device.
3. After the connection is completed, you can press
memory recall button to display the memory result on
LCD. Each result showed on LCD, the result will be
transmitted by Bluetooth immediately.
12
Troubleshooting
Problem
Probable Cause
Recommended Action
Nothing appears in
the display even
when the power is
turned on.
Low Battery Symbol
appears.
Batteries are drained.
Replace all batteries with new ones.
Battery are not correctly aligned with
terminals.
Reinsert batteries in the correct
position.
No reading after
measurement.
Suspicious blood
pressure results.
Batteries are drained.
Batteries are drained.
In colder temperatures batteries have
weaker electrical charges.
Device operation
Different battery brands have different
time is inconsistent. life spans.
Suspicious heart
rate results.
Perhaps the cuff was improperly
positioned.
Blood pressure naturally varies
throughout the day.
Bodily movement during device use.
Measurement shortly after exercise or
exposure to the outdoors.
Power switches off
automatically.
During measuring,
air re-inflates.
System design.
It could be a normal action if the user's
blood pressure is higher than the initial
pressure value, the device
automatically pumps to a higher
pressure by 40mmHg each time.
The arm cuff is not fastened properly.
Replace all batteries with new ones.
Warm up the batteries, or use the
device in a warmer setting.
Use Alkaline batteries and replace
all batteries at the same time with
same brand batteries.
Replace all batteries with new ones.
Adjust patient and arm cuff to
measure.
Rest a while, relax and measure
again.
Refrain from moving during
measurement.
Do not take measurements after
exercise or coming back from the
outdoors.
Push the power button again, and
then begin measure again.
Relax, and try to take a measure
again.
Check that the arm cuff is fastened
properly and retake the
measurement.
Error Codes
Meaning
Err Code
Err 0
Corrective Action
No pulse or detect pulses not enough.
Take off heavy clothes and retry again.
Err 1
Leakage in Cuff Pressure/Inflation too low.
The arm cuff is not fastened properly. Reapply the cuff, and take a measurement again.
Err 2
Pressure fault.
Rest a while, relax and retry again.
Err 3
Deflation fault.
The arm cuff is not fastened properly. Reapply the cuff, and take a measurement again.
Err
Memory error.
Take off batteries to reboot the device, then
take another measurement.
Low batteries.
Replace all batteries with new ones.
13
Care and Maintenance
1. Clean the device and arm cuff carefully only with a slightly moistened cloth.
2. Do not immerse the device in water. It may cause damage if water enters.
3. Do not use any gas, strong detergent, or solvents to clean the device, including the arm
cuff.
4. Disconnect the cuff and tubing from the monitor prior to storing.
5. Do not use any liquids on the monitor or cuff.
6. Use a soft, dry cloth to clean your monitor.
7. Do not store in direct sunlight, dust or excessive humidity.
8. Avoid extreme temperatures.
9. Do not disassemble the monitor or cuff.
10.Remove batteries if the monitor will not be used for an extensive period of time.
Applied Standards
This product conforms to the provisions of the EC directive MDD (93/42/EEC). The following
standards apply to design and/or manufacture of the products:
‧EN 1060-1
Non-invasive sphygmomanometers-Part1 : General requirements
‧EN 1060-3
Non-invasive sphygmomanometers-Part 3 : Supplementary requirements for electroMechanical blood pressure measuring system
‧EN 1060-4
Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system
accuracy of automated non-invasive sphygmomanometers
‧ANSI/AAMI Sp10
Electronic or automated sphygmomanometers
.ISO 14971
Medical devices-Application of risk management to medical devices. The Classification
according to IEC/EN 60601-1 sub-claues 5:
.Internally powered equipment
.IPX0
.Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air
or with oxygen or nitrous oxide
.Continuous operation
Technical Specification
• Measuring range :
Blood Pressure : 30~280 mmHg
Pulse Rate : 40~199 beats/min
• Calibration Accuracy: Blood Pressure : ± 3 mmHg
Pulse rate : ± 4% of reading
• Operating environment :
40℃
10℃
10 oC~40 oC (50 oF~104 oF)
with relative humidity up to 85% (non condensing)
• Storage/ Transportation environment
50℃
-20 oC~+50 oC (-4 oF~+122 oF) -20℃
with relative humidity up to 85% (non condensing)
• Power Source : 4 x 1.5 V AA batteries
approx. 275g (exclude batteries)
• Weight :
• Dimensions : approx. 113mm x 140mm x 57mm (W x H x D)
• Cuff circumference (M Size) : approx. 22 ~ 33 cm (9” ~ 13”)
14
FCC Statement
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
4. Consult the dealer or an experienced adio/TV technician for help.
5. FCC Caution: To assure continued compliance, (example – use only
shielded interface cables when connecting to computer or peripheral
devices). Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority
to operate this equipment.
6. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
7. This device complies with FCC radiation exposure limits set forth for
an uncontrolled environment. End users must follow the specific
operating instructions for satisfying RF exposure compliance. This
transmitter must not be colocated or operating in conjunction with
any other antenna or transmitter.
15
EMC Tables
Guidance and manufacturer's declaration-electromagnetic emissions
The BPM63ZB Arm Type Blood Pressure Monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of the BPM63ZB Arm Type Blood Pressure
Monitor should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment guidance
RF emissions
CISPR 11
Group 1
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Class B
Not
applicable
Not
applicable
The BPM63ZB Arm Type Blood Pressure Monitor uses RF
energy only for its internal function. Therefore, its RF
emissions are very low and are not likely to cause any
interference in nearby electronic equipment.
The BPM63ZB Arm Type Blood Pressure Monitor is
suitable for use in all establishments, including domestic
establishments and those directly connected to the public
low-voltage power supply network that supplies buildings
used for domestic purposes.
Guidance and manufacturer's declaration-electromagnetic immunity
The BPM63ZB Arm Type Blood Pressure Monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of the BPM63ZB Arm Type Blood Pressure
Monitor should assure that it is used in such an environment.
Immunity test
Electrostatic
discharge
(ESD)
IEC 61000-4-2
IEC 60601
test level
± 6 kV
contact
± 8 kV air
Power
3 A/m
frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
Compliance
Electromagnetic
environment-guidance
level
± 6 kV
Floors should be wood, concrete or ceramic tile. If floors
are covered with synthetic material, the relative
contact
humidity should be at least 30 %.
± 8 kV air
3 A/m
Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical
commercial or hospital environment.
16
EMC Tables
Guidance and manufacturer's declaration-electromagnetic immunity
The BPM63ZB Arm Type Blood Pressure Monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of the BPM63ZB Arm Type Blood Pressure
Monitor should assure that it is used in such an environment.
Immunity test
IEC 60601 Compliance
test level
level
Radiated RF 3 V/m
IEC 61000-4-3 80 MHz to
2,5 GHz
3 V/m
Electromagnetic
environment-guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the BPM63ZB
Arm Type Blood Pressure Monitor, including
cables, than the recommended separation distance
calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
d=1.2 √P
d=1.2 √P
d=2.3 √P
80 MHz to 800 MHZ
800 MHz to 2,5 GHz
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site surveyª,
should be less than the compliance level in each
frequency range.b
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
If the measured
field strength in the location in which the BPM63ZB Arm Type Blood Pressure Monitor is used
exceeds the applicable RF compliance level above, the BPM63ZB Arm Type Blood Pressure
Monitor should be observed to verify normal operation. If abnormal performance is observed,
additional measures may be necessary, such as reorienting or relocating the BPM63ZB Arm
Type Blood Pressure Monitor.
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
17
EMC Tables
Recommended separation distances between portable and mobile RF
communications equipment and the BPM63ZB Arm Type Blood Pressure Monitor
The BPM63ZB Arm Type Blood Pressure Monitor is intended fo use in an electromagnetic
environment in which radiated RF disturbances are controlled. The customer or the user of the
BPM63ZB Arm Type Blood Pressure Monitor can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the BPM63ZB Arm Type Blood Pressure Monitor as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum Separation distance according to frequency of transmitter
output power
of transmitter
150 kHz to 80 MHz
80 MHz to 800 MHz
800 MHz to 2.5 GHz
d=1.2 P
d=1.2 P
d=2.3 P
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in metres (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according
to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
18
Manufacturer:
AViTA Corporation
9F, No.78, Sec.1, Kwang-Fu Rd.,
San-Chung District,
24158 New Taipei City, Taiwan
No.858, Jiao Tong Road,
Wujiang Economic Development Zone
Jiangsu Province, P.R.C.
Postcode: 215200
Made in P.R.C.
72-B63MN-151

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Create Date                     : 2015:07:01 11:27:29+08:00
Modify Date                     : 2015:07:01 11:27:29+08:00
Producer                        : Corel PDF Engine Version 14.0.0.701
Author                          : AS70-賴琪珍
Creator                         : CorelDRAW
Title                           : 72-B63MN-151 無鬧鈴
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UV3BPW-15XX

Navigation menu