Accton Technology ML16035 MetroLin Outdoor 60GHz PTP + 5GHz + 2.4GHz User Manual MetroLinq Quick Start Guide

Accton Technology Corp MetroLin Outdoor 60GHz PTP + 5GHz + 2.4GHz MetroLinq Quick Start Guide

User Manual

–  1  –Quick Start GuideUnboxingAfter opening the box, you will find…◆MetroLinq™ (ML1-60-35, or ML1-60-19)◆PoE Power Supply◆Power CableTools/Items Required◆13 mm Socket Wrench◆Flat-Head Screwdriver◆Ethernet CablesOptions◆Standard Bracket ICC-BRACKET-STD◆Long Range Precision Bracket ICC-BRACKET-LR◆Alignment Scope ICC-SCOPE-9x50For helpful training and user-case information, please go to ignitenet.com/supportAssemblyThe MetroLinq™ Standard Bracket and Long Range Precision Bracket (both ordered separately) are designed for wall and pole mounting (25 mm - 80 mm pole diameter). Choose what is best for your location and select hardware accordingly.Welcome to MetroLinq™Interference-Free Gigabit WirelessEnsure all four position-locking bolts on the Standard Bracket are tight before installing.21431Install the Standard Bracket onto MetroLinq™ using four M8 bolts, lock washers, and flat washers.Ensure all four position-locking bolts on the Long-Range Precision Bracket are tight before installing.Install the Long-Range Precision Bracket onto the MetroLinq™ using four M8 15 mm bolts, spring-lock washers, and flat washers.2132434E052018-CS-R01150200001975XMetroLinq™ Outdoor 60GHz PTP + 5GHz + 2.4GHzML1-60-35 | ML1-60-19 www.ignitenet.com
Quick Start Guide–  2  –Grounding Power Up Standard Bracket AlignmentIgniteNet strongly recommends using the ICC-SCOPE-9x50 Alignment Scope for alignment. To install, place the scope on top of the MetroLinq™ housing and secure it with its thumb screw.Ensure the structure on which the unit is to be mounted is properly grounded and in compliance with local and national electrical codes.Verify that there is a good electrical connection to a grounding point (no paint or isolating surface treatment). Use the included (M4) screw to attach a grounding wire (not included) to the grounding point on the unit, and then to ground.Caution: The earth connection must not be removed unless all supply connections have been disconnected.Connect an Ethernet cable from the MetroLinq™ ETH PoE IN port to the PoE port on the power supply.121Connect Ethernet cable from the “LAN” port on the power supply to your LAN device.Connect the power cord to a nearby AC power source.Note: Do not adjust bolts A and B without first loosening 1 and 4 respectively.2314A23B
Quick Start Guide–  3  –SoftwareFor more configuration details and training, please go to ignitenet.com/supportLoosen coarse adjustment bolts 2 and 3 and set initial alignment. Don’t worry, you don’t have to be too accurate yet. After you have set the coarse alignment, tighten bolts 2 and 3.Loosen the horizontal fine-tune adjustment bolt 4. Use fine-tune bolt "B" to optimize the horizontal position. Re-tighten bolt 4.Loosen the vertical fine-tune adjustment bolt 1. Use fine-tune bolt "A" to optimize the vertical position. Re-tighten bolt 1.Initial alignment should be based on optical or visual alignment. After you achieve this, repeat steps 2 and 3 while watching the 60 GHz signal strength LED. Optimize position to the LED indicator.Ensure all bolts are fully tightened, remove the alignment scope (if installed), and enjoy Gigabit interference-free wireless.To configure your MetroLinq, connect your computer to the device through the LAN port of the power supply or directly to the ETH1 port on the device.The default IP mode is DHCP client, so if the device obtains an address from a DHCP server on the network, then use that IP (you can use the Discovery Tool from the IgniteNet support site to find the DHCP address). If the device does not obtain a DHCP address, it reverts to the fallback IP of 192.168.1.20 and you can access it on that IP. Direct your web browser to the correct IP and log in.username: rootpassword: admin123After you have logged in, follow the steps in the Setup Wizard to configure the device for your network.1234512After you have logged in, follow the steps in the Setup Wizard to configure the device for your network.2
Quick Start Guide–  4  –Safety and Regulatory InformationFCC Class BThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the followingmeasures:◆ Reorient or relocate the receiving antenna◆ Increase the separation between the equipment and receiver◆ Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected◆ Consult the dealer or an experienced radio/TV technician for helpFCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.For product available in the USA/Canada market, only channel 1–11 can be operated. Selection of other channels is not possible.IMPORTANT NOTE:FCC Radiation Exposure Statement:For Model Name : ML1-60-35This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 65 cm between the radiator & your body.Industry CanadaThis device complies with Industry Canada license-exempt RSSstandard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptibled'en compromettre le fonctionnement.For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 peuvent être exploités. Sélection d'autres canaux n'est pas possible.Europe - EU Declaration of ConformityHereby, IgniteNet Inc. declares that the radio equipment type:MetroLinq™ Outdoor 60GHz PTP + 5GHz + 2.4GHz, ML1-60-35 and ML1-60-19, is in compliance with Directive 2014/53/EU and Directive 2014/ 35/EU.The full text of the EU declaration of conformity is available at the following Internet address: www.ignitenet.com -> support. 60GHz Function:IMPORTANT NOTE:IC Radiation Exposure Statement:This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 66 cm  between the radiator & your body.Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 66 cm  de distance entre la source de rayonnement et votre corps.This radio transmitter [3857A-ML16035] has been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device.Le présent émetteur radio (3857A-ML16035) a été approuvé par Innovation, Sciences et Développement économique Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal d'antenne. Les types d'antennes non inclus dans cette liste qui ont un gain supérieur au gain maximal indiqué pour tout type listé sont strictement interdits pour une utilisation avec cet appareil. WLAN Function:
Quick Start Guide–  5  –Warnings and Cautionary Messages Hardware SpecificationsWarning: This product does not contain any serviceable user parts.Warning: Installation and removal of the unit must be carried out by qualified personnel only.Warning: When connecting this device to a power outlet, connect the field ground lead on the tri-pole power plug to a valid earth ground line to prevent electrical hazards.Caution: Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment.Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this device. Caution: Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards. ChassisSize (L x W x H:) ML1-60-35: 350 x 350  x 200 mm (13.78 x 13.78 x 7.87 in.)ML1-60-19: 190 x 190  x 120 mm (7.48 x 7.48 x 4.72 in.)Weight ML1-60-35: 3.5 kg (7.72 lb)ML1-60-19: 2 kg (4.41 lb)Temperature Operating: -30 °C to 55 °C (-22 °F to 131 °F)Storage: -40 °C to 70 °C (-40 °F to 158 °F)Humidity Operating: 10% to 90% (non-condensing)Network InterfacesPorts ETH RJ-45 Port: 1000BASE-T, passive PoESFP Port: 1000BASE-X60 GHz Radio Proprietary5 GHz Radio IEEE 802.11acRadio Frequencies 5150 – 5250 MHz (FCC)5725 – 5850 MHz (FCC)5745 – 5825 MHz (China)5180 – 5320 MHz (ETSI)5500 – 5700 MHz (ETSI)58.32 – 65.88 GHz Power SupplyPoE 24–48 VDC passive PoEPower Consumption 24 W maximumRegulatory CompliancesRadio EN 300 328 V1.8.1:2012EN 301 893 V1.7.1:2012EN 301 489-1 V1.9.2 (2011-09)EN 301 489-17 V2.2.1:2012FCC Part 15C 15.247/15.207 (2.4-2.4835GHz)FCC Part 15E 15.407 (5.150GHz-5.250GHz, 5.725-5.850GHz)Emissions EN 55022 2010+AC:2011EN 61000-3-2 2006+A1:2009+A2:2009FCC Class B Part 15Immunity EN 55024 : 2010EN 61000-4-2 : 2009

Navigation menu