Accurate Technology GPDS Transmitter User Manual PROSCALE Manual Rev E

Accurate Technology, Inc. Transmitter PROSCALE Manual Rev E

Users Manual Part 5

Download: Accurate Technology GPDS Transmitter User Manual PROSCALE Manual Rev E
Mirror Download [FCC.gov]Accurate Technology GPDS Transmitter User Manual PROSCALE Manual Rev E
Document ID488122
Application IDK9iBHlcGXZFj7hZ5XBxogQ==
Document DescriptionUsers Manual Part 5
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize135.35kB (1691879 bits)
Date Submitted2004-11-12 00:00:00
Date Available2004-11-12 00:00:00
Creation Date2004-10-21 11:40:32
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2004-10-21 13:59:54
Document TitleMicrosoft Word - PROSCALE Manual Rev E.doc
Document CreatorADOBEPS4.DRV Version 4.24
Document Author: 1

ON/OFF
Momentarily pressing the ON/OFF key will cause the display to turn on or off. The
Firmware Version is displayed on power-up or when ON/OFF key is pressed. While on, if
no key presses or positional changes occur within 15 minutes, the Digital Display will
automatically turn itself off to conserve battery life. While off, if a position change is
detected (.05mm or .002in) or the ON/OFF button is pressed, the display will
automatically turn itself on with no loss of measurement information.
(Programming Parameter Pr8. Factory default set to 15 minutes.)
Battery voltage is displayed by pressing and holding the ON/OFF key for 5 seconds while
display is turned on.
CAUTION: Pressing and holding the ON/OFF and MODE key for 10
seconds while the display is turned off will perform a full segment LCD
test AND re-set all programming parameters to factory defaults
MODE
The digital display can show measurement information in Imperial or Metric. To change
the current display mode, momentarily press the MODE key. With each key press the
display will cycle through decimal inches, fractional inches (1/16), (1/32), (1/64) (If
enabled by Programming Parameter Pr6) and metric (mm or cm based on setting of
Programming Parameter Pr5).
When the display is in a decimal mode (mm, cm or in) it will auto-range to the next
resolution if the value is displayable in the next range. This allows the display to be used
with Mitutoyo Digimatic® products in inch mode or different resolutions other than 2
decimal places.
When the display is in 1/16 or 1/32 inch fraction mode, a series of “bars” in the upper
right corner of the LCD each represent an additional 1/64th of an inch measurement. ie.
When in 1/16 inch mode and three bars are showing, the measurement displayed is
rounded down to closest 1/16 inch and each illuminated bar indicates an additional 1/64
of an inch (“heavy”) measurement. For better resolution switch to 1/32 or 1/64 fraction
mode. For the best resolution switch to a decimal mode.
When the measurement is greater than + 99 63/64 inches, a +100 or +200 will show in
the upper right portion of the LCD to indicate this amount must be added to the displayed
reading. ie: if the measurement is 154 5/8 inches, 54 5/8 and +100 will be displayed on
the LCD. If the measurement is -307 23/64 inches - 7 23/64 , +100 and +200 will be
displayed on the LCD.
The Resolution of the display can be set for Normal; (.01mm or .001in), Reduced; (.1mm
or .01in) or Increased; (.01mm or .0005in) (Programming Parameter Pr4.)
ProScale M150, M250 and all products with General Purpose LCD Digital Displays
26 of 26
+, 0, and – Keys
The + (plus), 0 (zero) and – (minus) keys are used to change the currently displayed
position to a different value. The 0 key forces the unit to display 0. Momentarily
depressing the + key increments the current position by one unit of measurement.
Momentarily depressing the – key decrements the current position by one unit. Pressing
and holding the + or – keys will cause the displayed position to change continuously.
Holding down the key will cause the amount of change to speed up. This allows for quick
adjustments over a range of large values. These keys can be “locked out” to prevent
accidental offset or zero entries. (See Programming Parameter Pr3)
Digital Display Functions
Lock Mode
The user can “lock-out” the position offset adjustment functions (+, -, 0 keys) to prevent
accidental changes of the current displayed position. To activate the lock mode, press
and hold the ON/OFF key and then momentarily press the MODE key. The word LOCK
on the LCD display will turn on or off with each lock/unlock operation. When the LOCK
symbol is displayed, the +, - and 0 keys will not change the displayed position. On
Displays with an auxiliary keypad: ABS and INC modes have independent lock
operations. (See Programming Parameter Pr3. Factory default is Enabled.)
Segment Offset Adjustment
For scales that are longer than 430mm (17 inches), multiple scale pattern segments are
installed end-to-end on the aluminum extrusion. This provides a quasi-absolute
measurement capability in which the readhead can calculate its position on any individual
scale segment but cannot determine which particular segment it is on. To solve this
problem, the Digital Display tracks which scale segment the readhead is on by detecting
the “splice” between one segment and adjacent segments.
In certain situations, the crossing from one segment to another may not be detected by
the display. This may occur if the readhead is disconnected from the digital display and
then moved along the scale to another segment. It may also occur if the readhead is
moved too quickly between two segments. (Maximum slew rate is 400mm/sec, 15in/sec)
If the segment tracking count is incorrect because of one of the above situations, the user
can re-adjust the display to correct the error. This adjustment is referred to as the
Segment Offset Adjustment.
To add one segment value (430.08mm) to the displayed value, hold the MODE key and
then momentarily press the + key. The displayed position will increase by 430.08mm
(16.933 inches). To subtract one encoder segment from the displayed value, press and
hold the MODE key and then momentarily press the - key. The displayed position will
decrease by 430.08mm.
(See Programming Parameter Pr1 and SCALES in Section 1 of this manual for
additional information. Factory Default is set to Enable this function.)
ProScale M150, M250 and all products with General Purpose LCD Digital Displays
27 of 27
Offset Addition
Offset addition allows the user to preset up to 3 different distances that are then added to
the Digital Displays position when selected. This allows the user to quickly switch
measurement modes from one reference point to another such as in the case of inside
and outside measurements on ProPanel or multiple stations on a vertical panel saw.
To utilize the offset addition feature, programming parameter Pr10 must be set to 1. The
display will then flash one of “offset” numerals 1, 2, 3 or 4 located in the upper left corner
of the LCD. Offset 1 is the ABS position with no offset addition. Offset 2 is the ABS
position with parameter Pr11 (Offset Addition 1) added to it. Offsets 3 and 4 have similar
functions with parameters Pr12 and Pr13 added to the ABS position respectively.
To move from “Offset” 1 to 2, momentarily press the F1 key. Each depression of the F1
key advances to the next offset. After offset 4, the display will move back to offset 1.
(See Programming Parameters 9, 10, 11, 12 and 13. Factory default is Disabled.)
Limit Mode
The digital display will show either “ LL “ for Low Limit or ” UL” for Upper Limit if a preprogrammed upper or lower reading is encountered. Upper and Lower limits are set with
programming parameters Pr16 and Pr17 but are only active if Pr14 is set to 1. Display
toggles between current position display and "LL" or "UL". The position is shown for 2
seconds and the "LL" or "UL" is shown for 2 seconds. This continues as long as a limit
has been exceeded. Limit monitoring is always active, even in programming mode.
Numerous Programming parameters, including Offset Addition and Limit mode indicate a
‘factory default set in inches’. The equivalent offset/limit value in mm or cm is applied if
you switch the MODE of display to mm or cm. ie These parameter values take on the
unit of measurement MODE (mm, cm or inches ) active when programming is entered.
Scaling
All General Purpose Digital Displays have the ability to “scale” the actual measurement.
This function is useful when the actual measurement must be multiplied or divided before
being displayed. Care should be taken when using this function since invoking it will
cause the unit to display a reading different than the actual measured or traversed value.
This function is set using Programming Parameter Pr7. The Factory Default is set to
1.000 - No Scaling
Changing the Batteries
A low battery indicator will appear in the lower left corner of the LCD display when new
batteries are needed.
Surface Mount Displays: remove the screws in the upper right and lower left corners.
Pull the cover off. Remove the old batteries. Reinstall new AA Alkaline batteries, noting
the proper orientation. Replace the cover and tighten the screws.
CAUTION:
DO NOT BEND BATTERY CLIPS!
THESE CLIPS ARE DESIGNED TO BE LOOSE WHEN THE CASE IS OPEN AND WILL COMPRESS AND SECURE THE
BATTERIES IN PLACE WHEN THE CASES ARE SCREWED TOGETHER.
Panel Mount Displays: Remove and replace 2D batteries noting proper orientation.
ProScale M150, M250 and all products with General Purpose LCD Digital Displays
28 of 28
24VDC Operation
The 24VDC Digital Displays have some additional functions that are not available on
battery powered displays.
The 24VDC displays are designed to run on DC voltage ONLY.
DO NOT ATTEMPT TO OPERATE THESE DISPLAYS USING AC VOLTAGE
COMMON
SPC output
SIGNAL
SPC
12-24VDC
Readhead
12-24VDC
Surface Mount Above,
Panel Mount Right
COMMON
SIGNAL OUTPUT
Readhead Input
Limit/Monitor Signal Output
This function is available on 24VDC powered Digital Displays ONLY.
A connector provides a solid-state output (.1A / 30 VDC) that can be configured to
activate on either a position drift (MONitor) condition or a measurement limit (LIMIT)
error. The output can be configured for normally open (N/O, not conducting to ground) or
normally closed (N/C, conducting to ground). Although the Digital Display LCD flashes
when either a position drift (MONitor) condition or a measurement limit (LIMIT)error is
encountered, the output signal only changes state once for out of limit condition and then
toggles back when an in limit condition is restored.
For additional programming information see Limit Mode above and MONitor Mode below.
Caution: These functions are active during Display Programming. If their parameters are
changed during programming the output signal could become active.
(See Programming Parameters 9, 14 and 15. Factory default is MONitor, N/O.)
Backlighting
This function is available on 24VDC powered Digital Displays ONLY.
LCD backlighting can be configured to always remain OFF, to always remain ON or to
come on when any key is pressed and remain on for 3, 7 or 15 seconds.
(See Programming Parameter 22. Factory default is on for 3 seconds.)
ProScale M150, M250 and all products with General Purpose LCD Digital Displays
29 of 29
Auxiliary Keypad
As seen on the Panel Mount Display
As seen on the Surface Mount Display
The Auxiliary Keypad is found only on Digital Displays that are Fully Programmable
(See Programming Parameter 9. Factory default is all keys enabled.)
ABS - INC
The Digital Display has two measurement “indexes”. One is referred to as ABS and the
other is INC. The ABS measurement setting is designed to allow the user to set a
current position on the display referenced from a fixed or known position such as a saw
blade, or stop. The INC measurement setting is designed to take relative distance
measurements from one arbitrary point to another. The systems operate independently
allowing separate position offsets to be programmed. The ABS position of the measuring
system is not lost when using the INC settings.
ABS Mode – The ProScale automatically enters ABS mode when power is first applied.
This is indicated by the ABS symbol in the upper left corner of the display. While in the
ABS mode, all position measurements are related to the current system reference point
(i.e. sawblade, stop, origin etc.) To enter the INC mode, momentarily press the ABS/INC
button.
INC Mode – While in the INC mode, the INC symbol is shown in the upper left corner of
the display. When the INC mode is initially entered, the displayed position will change to
reflect a new reference point at the current position of the readhead. This is typically a
position of zero (0) but may be changed by using the + or - keys to provide an offset.
Moving the readhead in either direction will display the distance moved from the initial
INC starting point (plus any offset). To complete another incremental measurement from
the new position, momentarily press the ABS/INC key. The display will again change to
0 (or the previously programmed offset). To return to the ABS mode, press and hold the
ABS/INC key for approximately 3-4 seconds.
HOLD
The Digital Display provides a feature that allows the displayed position to be “frozen” in
time while the readhead is moved from its measuring position.
This allows
measurements to be captured on the display and held for later viewing regardless of the
current readhead position. To activate the HOLD mode, momentarily press the HOLD
key. The HOLD symbol will be shown in the upper left corner of the display. The
currently displayed position and selected key presses will be frozen at this point. To
release the HOLD feature, momentarily press the HOLD key again.
ProScale M150, M250 and all products with General Purpose LCD Digital Displays
30 of 30

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2004:10:21 11:40:32
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : 1
Creator                         : ADOBEPS4.DRV Version 4.24
Title                           : Microsoft Word - PROSCALE Manual Rev E.doc
Modify Date                     : 2004:10:21 13:59:54-07:00
Page Count                      : 5
Page Mode                       : UseThumbs
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SMIGPDS

Navigation menu