Aclara Technologies 11583-2 TRANSMITTER FOR METER READING User Manual
Aclara Technologies LLC TRANSMITTER FOR METER READING Users Manual
Users Manual
MTU Instructions ALL MTU Instructions as of 10/1/2009 Instructions Included Document Page 471-2000 – General Installation & Wiring Guidelines ........................................................ 3 471-2001 – for Rockwell/Equimeter/Sensus Gas Meters (Direct Mount).......................... 15 471-2002 – for Most Popular Water Meters........................................................................ 19 471-2003 – for American Meter Company Gas Meters (Direct Mount) ............................. 25 471-2004 – for American Meter Company Gas Meters (Indirect Mount)........................... 29 471-2005 – for Carson Industries Pit Lids.......................................................................... 33 471-2006 – for Armor Access Pit Lids................................................................................ 37 471-2007 – for Invensys/Icon MTU/Electric Meter............................................................. 41 471-2008 – for Hexagram Submetering Pulse Adapters .................................................. 43 471-2009 – for AMCO/ABB Water Meters........................................................................... 51 471-2010 – for Neptune/Schlumberger Water Meters....................................................... 55 471-2011 – for Sensus/Invensys Water Meters ................................................................. 59 471-2012 – for Hersey Water Meters................................................................................... 61 471-2013 – for Badger Water Meters .................................................................................. 63 471-2014 – for M-Log Sensors ............................................................................................ 65 471-2015 – for Rockwell/Equimeter Intermediate/Large Capacity Gas Meters .............. 67 471-2016 – for American Commercial/Industrial Gas Meters .......................................... 73 471-2017 – for Sprague/Schlumberger 250 Gas Meters (Bracket-direct-mount) .............. 79 471-2018 – for Lancaster 250 Gas Meters (Bracket-direct-mount)..................................... 83 471-2019 – for Lancaster 175 Gas Meters (Bracket-direct-mount)..................................... 87 471-2020 – for Mini-Max ....................................................................................................... 91 471-2021 – for Sprague 175 Gas Meters (Indirect Mount) .................................................. 95 471-2022 – for Metron-Farnier Water Meters .................................................................... 101 471-2023 – for Nicor Composite Pit Lids .......................................................................... 103 471-2026 – for American Meter Commercial & Industrial Diaphragm Gas Meters (Hexagram Large Meter Pulser)............................................................................................ 107 471-2027 – for Rockwell/Equimeter Intermediate and Large Capacity Gas Meters (Hexagram Large Meter Pulser)............................................................................................ 109 471-2028 – for Actaris Commercial & Industrial Diaphragm Gas Meters (Hexagram Large Meter Pulser)............................................................................................ 119 471-2029 – for Dresser Roots-type Gas Meters................................................................ 125 471-2030 – for Romet Roots-type Gas Meters.................................................................. 131 October, 2009 Page 1 MTU Instructions ALL MTU Instructions as of 10/1/2009 Instructions Included (Continued) Document Page 471-2031 – for Actaris/Schlumberger/Sprague ‘Slant-face’ Gas Meters........................137 471-2032 – for Armorcast Composite Pit Lids..................................................................141 471-2033 - for Actaris/Schlumberger/Sprague Pit/Curbside Gas Meters ......................145 471-2034 – for American Meter Company 5B-225 Gas Meters........................................149 471-2035 - for Sensus/Equimeter/Rockwell 415 Gas Meters...........................................153 471-2036 - for Sensus/Equimeter/Rockwell 175S Gas Meters ........................................157 471-2037 - for Sensus/Equimeter/Rockwell 175-EMCO Gas Meters...............................161 471-2038 - for Sensus/Equimeter/Rockwell Residential Gas Meters (Indirect Mount) ...163 471-2040 – for Landis & Gyr Focus Family Electric Meters ............................................167 471-2041 – for Landis & Gyr S4 Family Electric Meters ..................................................169 471-2042 – for DFW Rectangular Composite Pit Lids......................................................171 471-2043 – for Carson Industries Polyplastic Pit Lids.....................................................175 471-2044 – for Sensus/Equimeter/Rockwell Gas Meters (Metric - direct mount) ............179 471-2045 – for Mid-States 12" Round Pit Lids ..................................................................183 471-2046 – for Alliance Rectangular Pit Lids....................................................................187 471-2047 - for Actaris/Schlumberger/Sprague ‘Flat-face’ Gas Meters ...........................189 471-2051 – for Actaris Dattus fm2 and fm3 Commercial & Industrial Diaphragm Gas Meters .......................................................................................................195 471-2052 – for Severn-Trent SmartMeter Water Meters...................................................197 471-2053 – for Endress & Hauser PROMAG Water Meters .............................................199 471-2054 – for Actaris Cyble Water Meters.......................................................................201 Page 2 MTU Instructions General Installation and Wiring Guidelines Intentionally Left Blank The FCC wants you to know….. This equipment has been tested and complies with Part 15 and Part 90 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, try to correct the interference by one or more of the following measures: • Reorient or relocate the equipment. • Increase the separation distance between the affected equipment and receiver. • Consult Hexagram, Inc. for help. Any changes or modifications to this equipment not expressly approved by the Hexagram, Inc. could void the authorization to operate the equipment. FCC RF Exposure Guidelines Hexagram’s low power RF devices and their antennas must be fixed-mounted on indoor or outdoor permanent structure(s) providing a separation distance of at least 20 cm from all persons during normal operation. This device is not designed (and it has no external connection) to operate in conjunction with any other antennas or transmitters. No other operating instructions for satisfying RF exposure compliance are needed. This unit has no user or installer serviceable parts, and requires no field adjustment or calibration. Units are sealed at the factory, and disruption of this seal could void the authorization to operate the equipment. Hexagram, Inc. 23905 Mercantile Road Cleveland, OH 44122 Page 14 MTU Instructions General Installation and Wiring Guidelines Purpose & Scope This instruction outlines general practices and procedures for the installation and wiring of standalone, electronic interface Hexagram STAR MTUs. When installing an MTU, always refer to these instructions in addition to any specific instructions for the meter/MTU combination you will be installing and programming. Note: STAR MTUs are shipped to the customer in sealed enclosures and have passed extensive testing and calibration procedures at the factory. No additional calibration or adjustment is required, or can be made, without breaking thefactory seal. As calibrated, these devices radiate a tiny fraction of the power allowable byFCC Radio Frequency Exposure Limits 47 CFA CH 1.1310. There are no radio-frequency safety issues relating to the use of this product based on this regulation. 471-2000 - 7/25/2007 Page 3 MTU Instructions General Installation and Wiring Guidelines Recommended Supplies We recommend the following supplies, for which quantities will depend upon the number of MTUs to be installed and the conditions encountered at each installation location. Item AMP Tel-Splice, 2-conductor Scotchlok, UR 2-3 wire gel-filled butt connector 3-conductor, 22 ga, solid wire, black UV jacket 3-conductor, 22 ga, solid wire, grey UV jacket AA alkaline battery, 1.5 volt (for Psion) Back-up battery for Psion MTU Programmer 3M DBR-6 Direct Burial Kit (for pit unit splices) Sealant — White RTV Black electrical tape Tie-wraps, black Staples, telephone type, 9/16” (Arrow T-25) Sharpie permanent marker, fine point Plastic masonry anchors #6 x 1”, ¼” diameter Hexagram Part Number 043-1910 043-1913 070-0506 070-0508 042-0036 042-0037 043-1912 084-0082 Quantity As needed As needed As needed As needed As needed As needed As needed As needed As needed As needed As needed As needed As needed for use with Original Flatpak MTUs Hexagram plastic spacers Phillips exterior screws 8 x 2 ½” (deck screw) Phillips exterior screws 8 x 3” (deck screw) Drywall screws, #6 x 1-5/8” Phillips, coarse (for indoor use) Drywall screws, #6 x 2” Phillips, coarse (for indoor use) MTU spacer for pipe or bar mount 18″ heavy-duty UV-resistant tie wrap (for bar mounting gas MTUs) 10-32 x 1½″ pan head machine screw (for bar mounting gas MTUs) 10-32 nut, stainless steel (for bar mounting gas MTUs) #10 7/16” flat washer, stainless steel (for bar mounting gas MTUs) 056-5155H1 As needed As needed As needed As needed 056-5155K 067-0030 As needed 069-103248CS As needed 069-3011 069-3004 As needed for use with NEW Compact Flatpak MTUs Long Spacers/Standoffs (for pit lid installations) 056-8150L Short Spacers/Standoffs (for pit lid installations) 056-8150S Phillips exterior screws 8 x 1 3/4” (deck screw) Drywall screws, #6 x 1-5/8” Phillips, coarse (for indoor use) Page 4 As needed As needed As needed As needed As needed As needed As needed MTU Instructions General Installation and Wiring Guidelines Recommended Tools MTU Wiring • General - Many MTUs connect to the meter by means of a 3-conductor, 22gauge solid conductor wire. The wire is housed in a PVC jacket with UV inhibitors. A black-jacketed wire is supplied on single-port MTUs and for port 1 of dual-port MTUs. A grey jacket is used for the port two input to dual port MTUs. • • • • • • • • • • • • • • • • • • • Cordless drill (⅜”, variable speed, 1800-2000 rpm, adjustable torque settings) Drill bit, ¼”, carbide tipped Drill bit, ¼” x 12”, carbide tipped #2 Phillips power screwdriver bits Stapler for ¼” wire and cable (Arrow T-25M) Diagonal side cutters/wire cutters Needle nose pliers – small Wire stripper Connector crimping tool 3M 9EY Safety goggles Screwdriver, #1 Phillips Screwdriver, #2 Phillips Screwdriver, 5/16” slotted Screwdriver, ¼” slotted Screwdriver, small slotted, ⅛” blade Hammer Clipboard Flashlight with batteries Extension cord with trouble light MTU Programmer with cable, programming coil and STAR Programming Software Wire Length – MTUs are provided with a standard wire length of 12 feet. Additional wire may be used if necessary. A maximum run of up to 500 feet can be used to position the MTU in a favorable location. Use like-colors for cable jackets and individual wires when extending MTU wiring. Some specific meters may impose other wire length limitations. Consult the meter manufacturer. Wire Routing - Wires should be attached to walls with 9/16” staples. If wire clearance holes are needed to route wire from the meter to the MTU, drill a ¼” hole using an appropriate drill bit. The installer is responsible for the selection of an appropriate location for any hole to be drilled. Note: Wiring must be in accordance with all national and local codes. Wire Protection - A drip loop below the MTU is not required. Inspect wire to ensure that routing and stapling have not caused wire damage. Pull the wire lightly at each staple to make sure that the staple is not set too tightly. Any splices made to wire must be suitable for the environment and made in accordance with national and local codes. Page 5 MTU Instructions General Installation and Wiring Guidelines They must be secure and made in accordance with the connection supplier’s instructions. Generally, gel-filled Insulation Displacement Connectors (IDCs) such as 3M ScotchLok or AMP Tel-Splice connectors should be used on all wire-to-wire connections. Since MTU transmissions are similar in nature to cellular phone signals, a cellular phone can be used to help to determine if a location is suitable for MTU mounting. If the cellular phone signal drops dramatically or indicates no signal at the desired location, it is possible that the MTU signal will also be blocked at this location. In this case, the MTU will have to be mounted in a different location, possibly on the outside of the structure. Keep the MTU away from all other electrical wires. Note: Do not mount the MTU under wiring such as Romex, AC power wires, cable TV wire, or telephone wire. Do not allow these wires to lay on top of, or in front of the MTU. Splices located outdoors or in meter pits should be further protected through the use of a direct burial kit. This consists of a gel-filled plastic tube that houses the individual wire-to-wire splices to provide additional protection from the elements. Note: Keep the MTU six inches away from metal items such as pipes, conduit, electric meters, electrical boxes, and downspouts. Make sure screws used to mount the MTU do not protrude and pierce or otherwise damage any wires, cables, or pipes. MTU Positioning and Mounting General - MTUs must be positioned and mounted properly to ensure optimum RF signal propagation. Each MTU contains an internal antenna near the top front surface of the sealed enclosure. As a result, the MTU should always be mounted vertically and the STAR logo should face the installer. Page 6 Use of Spacer – There are two primary styles of MTUs. The Original Flatpak STAR MTU requires the use of a spacer (Hexagram Part Number 056-5155H1) when the MTU is mounted on any surface other than wood. The NEW Flatpak STAR MTU is a modified design that can be directly mounted to a variety of surfaces without the use of a spacer. See the examples below for additional information. MTU Instructions General Installation and Wiring Guidelines NEW Flatpak STAR MTU – An example of the NEW Flatpak STAR MTU is shown below. These MTUs are approximately 6.5” x 4.25” x 1.5” thick, and can be mounted on most surfaces without the use of a spacer. Original Flatpak STAR MTU – An example of an Original Flatpak STAR MTU is shown below. These MTUs are 6.5” x 5.5” X 1” thick, and require a spacer if mounted on any material other than wood. Note: Do not use a spacer when mounting an Original Flatpak STAR MTU on wood. Page 7 MTU Instructions General Installation and Wiring Guidelines Outdoor Mounting MTUs mounted outdoors are typically mounted to the side of buildings, to a stationery post, to the piping surrounding the meter, or to a pit lid. Mounting to a Buiding or Post If the unit is being mounted to the outside of a building, the MTU will be connected to wires that lead from the inside to the outside of the building. If existing wire is used, it must be of the same quality as specified in MTU Wiring. It must also be in good condition, without breaks, damage, or corrosion. Step 1 – Select a mounting location for the MTU that will allow optimum signal transmission. Step 2 – Run wiring from the MTU to the meter. If a splice is required, it may be placed inside or outside. For special circumstances, contact your supervisor. If using existing wiring, remove any box that houses the outside wires. Step 3 – Mount the MTU on the side of the building. • The MTU must be mounted level, vertically with the STAR logo facing the installer. Allow a 1” space between the top of the MTU and the overhang of the siding above it. This is critical for proper radio signal transmission. • Use a Spacer (Hexagram Part Number 056-5155H1) if mounting an Original Flatpak STAR MTU on a non-wood surface. Page 8 CAUTION! Do not over tighten screws. Excessive torque will crack the MTU enclosure. Do not tighten screws beyond the point that the MTU touches the mounting surface. Step 4 – Make the appropriate connections to the meter. Refer to the specific MTU Instruction for the meter in use. Bar or Pipe Mounting Particularly in outdoor gas applications, it is sometimes convemient to mount the MTU to the connecting piping. With the Original Flatpak STAR MTU this is easily done using a bar-mount spacer and two 18” long tie-wraps, (See Recommended Supplies.) Step 1 - Thread the tie-wraps into the bar mount spacer as shown here. MTU Instructions General Installation and Wiring Guidelines Step 2 - Attach the spacer to the MTU using #10-32 stainless steel screws, nuts and washers. Tighten the screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Pit-Lid Mounting For water or gas meters located in meter pits, MTUs can be mounted to the lower surface of the pit lid if an approved, nonmetallic pit lid is used. In these applications, the MTU is mounted with it’s front surface facing the bottom surface of the lid, as shown below Original Flatpak STAR MTU Step 3 - Wrap the tie wraps around the bar as needed, pulling the ties around (through the spacer plate) as they are tightened. Step 4 - Adjust the MTU as needed and pull the tie wraps tight. When NEW Flatpak STAR MTUs are mounted in this manner, spacers are used between the MTU mounting tabs and the lower surface of the pit lid, as shown below. Revised Flatpak STAR MTU Step 5 - Trim off the excess tie wrap, leaving about a ½” tab. Step 6 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 9 MTU Instructions General Installation and Wiring Guidelines A long spacer is available, for use when the lower surface of the pit lid is a flat, solid surface. A short spacer is used when the lower surface of the pit lid in use has a ribbed construction. Do not mount the MTU if large metal objects, such as heating ducts, block both the front and rear of the MTU. If absolutely necessary, a single large metal object may be located several feet away from the MTU. Unfinished Basement Step 1 – Select a mounting location for the MTU that will allow optimum signal transmission. In unfinished basements, this is typically high on a ceiling joist, at least a few inches away from outside walls. Contact Hexagram for information on approved non-metallic pit-lids. Indoor Mounting For an inside mount, mount the MTU vertically on a ceiling joist. It is important to mount the MTU as high as possible. Note: The MTU must be mounted above grade. Because the outside wall of a building can have metal siding or foil insulation, keep the MTU a few inches away from the outside wall. Transmissions easily pass through wood and masonry. Do not install an MTU inside if the basement has a metal ceiling or foil-lined insulation in the ceiling or if it has foil on the sidewalls running from grade to ceiling. This will prevent the signal from transmitting effectively. Large metal objects such as heating ducts, steel cabinets or metal ceiling structures can block MTU transmissions. Select locations that are at least five to ten feet away from objects such as these. Page 10 Step 2 – Mount the MTU. • The MTU must be mounted level, vertically with the STAR logo facing the installer. Allow a 1” space between the top of the MTU and any overhang above it. This is critical for proper radio signal transmission. • Use a Spacer (Hexagram Part Number 056-5155H1) if mounting an Original Flatpak STAR MTU on a non-wood surface. CAUTION! Do not over tighten screws. Excessive torque will crack the MTU enclosure. Do not tighten screws beyond the point that the MTU touches the mounting surface. MTU Instructions General Installation and Wiring Guidelines Step 3 – Run wiring from the MTU to the meter. Carefully staple the wire to the wall every 18” and at every change in direction using 9/16” staples. All turns are to be at right angles. If wire must be run on masonry, secure it with wire clips. Run wires parallel to the joist. If a joist must be crossed, run at a 90 degree angle. If the MTU input cable must be extended, use an appropriate splice. Make sure inner conductors are not nicked during stripping. Step 4 – Make the appropriate connections to the meter. Refer to the specific MTU Instruction for the meter in use. Finished Basement Step 1 – Select a mounting location for the MTU that will allow optimum signal transmission. In Finished basements, this may be high on a ceiling joist in an unfinished section of the basement or high on an interior wall near a window or outside wall, but at least a few inches away from outside walls. CAUTION! Do not over tighten screws. Excessive torque will crack the MTU enclosure. Do not tighten screws beyond the point that the MTU touches the mounting surface. Step 3 - Run wiring from the MTU to the meter. Run all wiring behind the wall if possible. Carefully staple the wire to the wall every 18” and at every change in direction using 9/16” staples. All turns are to be at right angles. If wire must be run on masonry, secure it with wire clips. Run wires parallel to the joist. If a joist must be crossed, run at a 90 degree angle. If the MTU input cable must be extended, use an appropriate splice. Make sure inner conductors are not nicked during stripping. Step 4 – Make the appropriate connections to the meter. Refer to the specific MTU Instruction for the meter in use. Note: Ceilings may contain metal. Therefore, the MTU should be placed 2 to 3 inches down from a plaster or ‘dropped’ ceiling. Step 2 – Mount the MTU. • The MTU must be mounted level, vertically with the STAR logo facing the installer. Allow a 1” space between the top of the MTU and any overhang above it. This is critical for proper radio signal transmission. • Use a Spacer (Hexagram Part Number 056-5155H1) if mounting an Original Flatpak STAR MTU on a non-wood surface. Page 11 MTU Instructions General Installation and Wiring Guidelines Do 9 Do check your cell phone for presence of a strong signal before entering a building or basement. Do install the MTU if the signal remains strong at the installation location. (Note: This is a guideline only. It does not guarantee that the MTU will be received by the DCU. However, if cell phone service is affected by the location, it is possible that the MTU transmission will also be blocked.) 9 Do select the best possible location for MTU installation that will allow optimum signal transmission. 9 Do select a location for MTU installation that is above grade. 9 Make sure that the MTU is located near an outside wall, but not on an outside wall. 9 Make sure the MTU in installed within 500 feet of the meter. 9 Do make sure that no staples have pierced the installation wire. 9 Do mount the MTU vertically and level with the STAR Logo facing the installer. 9 Do keep the MTU a few inches away from the outside wall in case of metal siding or foil insulation. 9 Do use a spacer when mounting an Original Flatpak STAR MTU on any surface other than plaster or wood. 9 Do use a spacer if you need to make a splice near the MTU and if the MTU is mounted outside. 9 Do keep the MTU at least 6” (the width of the MTU) from all pipes, conduit, electric meters, electrical boxes, downspouts, dumpsters, garbage cans, water, electric and gas meters, etc. 9 Do keep at least 4” between MTUs side to side and 3” top to bottom, when installing multiple MTUs. Page 12 9 Do mount an MTU 2” to 3” below a plaster ceiling or the metal grid of a drop ceiling. 9 Do use amp splices and 3M DBR Gel kits when making splices in pits. 9 Do make sure the correct meter type and size is selected. 9 Do make sure the MTU is programmed on. 9 Do program the MTU as the last step. Make sure it is mounted, wired, all splices are completed and tucked into place and wires are stapled in place. 9 Do follow all national and local codes when installing MTUs. 9 Do inspect all splices, connections and wiring for damage. 9 Do route all wires away from the MTU case. MTU Instructions General Installation and Wiring Guidelines Don’t 9 Don’t install the MTU if the cell phone signal was strong outside the building or basement and then goes into “no service” or a very weak signal at the MTU installation site. 9 Don’t select a location for MTU installation that is easy to install, but will not allow for good signal transmission. 9 Don’t select a location for MTU installation that is below grade. 9 Don’t place the MTU under Romex, AC power wires, cable or TV wire, telephone wire, etc. Don’t allow these wires to lay on top of or in front of the MTU. 9 Don’t mount the MTU right next to conduit or metal pipes. 9 Don’t over tighten the screws when mounting the MTU. 9 Don’t route the MTU wire along the top or front of the MTU. 9 Don’t mount the MTU near 2 or more metal objects such as heating ducts. 9 Don’t mount the MTU behind metal objects such as washers, dryers, furnaces, hot water tanks, metal sinks, metal shelves, dumpsters, garbage cans, water, electric or gas meters, or any other large metal objects. 9 Don’t mount the MTU in a basement that has metal ceilings unless there is an opening in the ceiling that is above grade where the MTU can be installed. 9 Don’t mount the MTU near electrical wires. 9 Don’t stack MTUs on top of each other (back to front). 9 Don’t install an MTU if the case is cracked or broken. 9 Don’t mount the MTU in the center of a basement. 9 Don’t make a connection or splice if any of the wires are nicked or cut. Restrip the wire and start over. 9 Don’t damage insulation with staples, or by rough handling. 9 Don’t stretch wire when installing. 9 Don’t exceed 500 feet total wire length between the MTU and the meter. Page 13 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315, RT210. Parts Required Ref. # 10 11 12 13 14 Item Gasket (pre-applied to MTU) Blue Coupler, MTU Retaining Shaft, MTU MTU, Direct Mount Magnet Gear, Blue, Standard #6 Round Spacer, Nylon 10-24 x 1 1/8” Slotted, Fillister Head Machine Screw #10 Flat Washer, Acetal #6 x 1 1/4” Combo Panhead Sheet Metal Screw Register Cover, MTU #10 x 3/4” Tri-lobular Screw Gear, Red, Extended Gear, Yellow, Odometer 471-2001 - 7/14/2008 Part Number 066-5155C 056-5155E 056-5155D per project 036-0002 056-5155G4 068-60812-EX 069-102436H 069-3019 069-060040C3 109-7712A 069-101424A2 056-5155G3 056-5155G2 Quantity Page 15 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Step 4 – Turn the MTU over and insure that there is a pre-applied gasket on the back of the MTU as shown below. Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips bit Safety goggles Phillips screwdriver Slotted screwdriver Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws. Discard the screws and cover. Step 2 - Remove the register by removing the two screws. Set the register aside. Discard the screws. Step 3 - Insert the four 10-24 x 1⅛” screws through the holes on the MTU as shown. Note: Couplers are pre-assembled to the MTU. Insure that the couplers are firmly attached to the shaft and that the coupler on the front side of the MTU contains the magnet. Also, verify that the plastic washer is in place between the rear coupler and the MTU. Step 5 - Position the MTU on the meter. Rotate the coupler so that the gear tooth on the coupler engages with the gear teeth on the gas meter. Orientation is not critical, but you should be able to feel the teeth “bite” when you turn the coupler from the front of the MTU. Step 6 - Tighten the four 10-24 x 1-⅛” screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Tighten corner to corner. Step 7 - Check the coupler. It should have slight play — it should not bind or turn too freely. Page 16 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 8 – Select gear to fit between the register and the MTU without binding. Typically, the correct gear can be selected based upon the type of index in use, as shown in the following table. Type of Index Step 9 - On the register, insert the screws and spacers. Coupler Drive Gear Plastic, dialtype Blue Gear (Part # 056-5155G4) Brass, dialtype Red Gear (Part # 056-5155G3) Note: Spacers may not be required with odometer-style registers. Plastic, odometertype Yellow Gear (Part # 056-5155G2) Step 10 - Mount the register to the MTU, fastening it to the mounting holes shown below. Hand tighten to a torque not to exceed 3-5 inch-pounds. Make sure the index register gear and the MTU coupler gear are engaged. Place the selected gear into the coupling. The head of the pin on the gear needs to be facing out. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on steps 9-12. Page 17 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 11 - After you feel engagement between the index register gear and the MTU coupler gear, tighten the register screws until they are snug. Step 12 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Page 18 Step 13 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 14 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for Most Popular Water Meters Purpose & Scope This instruction provides wiring information for connecting STAR MTUs to any of the following popular water meters: • AMCO and/or ABB water meters (all sizes) equipped with Invision, Scancoder, RS Pulser, or Type A Industrial Pulser registers and with the AMCO/ABB V100 (PSMT) meter and the S130/5UM hot and cold water meters. • Neptune and/or Schlumberger water meters (all sizes) equipped with ARB-V, Auto/ProRead or E-Coder PLUS registers. • Sensus and/or Invensys water meters (all sizes) equipped with ECR or ICE registers. • Hersey water meters equipped with Translator or ER2 registers. • Badger water meters (all sizes) equipped with Read-O-Matic, RTR or ADE registers. • Metron water meters (all sizes) equipped with OER registers. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. 471-2002 - 7/24/2006 a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw hand tight. Over tightening the screw can stress and possibly damage the wire. b. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Page 19 MTU Instruction for Most Popular Water Meters Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. AMCO/ABB Scancoder Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Cable Scancoder Register Red G (Green) Black B (Black) White R (Red) Wiring Diagrams AMCO/ABB RS Pulser AMCO Invision MTU Cable Invision Register MTU Cable RS Pulser Register Red G (Green) Red R (Red) Black B (Black) Black B (Black) White R (Red) White B (Black) No Connection G (Green) Page 20 MTU Instruction for Most Popular Water Meters AMCO/ABB Type A Industrial Pulser MTU Cable Type A Industrial Pulser Register Red + Positive AMCO/ABB V100 (PSMT) MTU Cable V100 (PSMT) Cable Red Red Black Blue White Blue Black - Negative No Connection Black White - Negative No Connection Yellow AMCO S130/5UM Hot Water AMCO Digital Register MTU Cable S130/5UM Cable MTU Cable AMCO Digital Register Red Brown Red R (Red) Black White Black B (Black) White White White B (Black) No Connection G (Green) Page 21 MTU Instruction for Most Popular Water Meters AMCO S130/5UM Cold Water Neptune/Schlumberger E-Coder PLUS MTU Cable E-Coder PLUS Register MTU Cable S130/5UM Cable Red Brown Red B (Black) Black White Black G (Green) White White White R (Red) Neptune/Schlumberger ARB-V or Auto/ProRead MTU Cable ProRead Register Red B (Black) Black G (Green) White R (Red) Note: Auto/ProRead registers must be programmed for 3-wire mode. Page 22 Sensus/Invensys ECR or ICE MTU Cable Sensus/Invensys Register Red R (Red) Black B (Black) White G (Green) Note: The 8-digit Sensus ICE Register must be programmed to deliver 6 consecutive digits of reading information for proper operation with STAR MTUs. MTU Instruction for Most Popular Water Meters Hersey Translator Badger RTR MTU Cable RTR Cable MTU Cable Hersey Register Red R (Red) Red R (Red) Black B (Black) Black B (Black) White G (Green) White G (Green) Note: The Hersey Translator Register must be programmed for 6-digit readings for proper operation with STAR MTUs. Hersey ER2 MTU Cable ER2 Cable Red R (Red) Black B (Black) White G (Green) Note: Some RTR registers may be provided with only a black wire and a white wire with a shield. For this variation, Trim the shield off and connect as listed below. MTU Cable RTR Cable Black B (Black) White B (Black) Red W (White) No Connection White-Shield Page 23 MTU Instruction for Most Popular Water Meters Badger ADE Metron OER Register MTU Cable ADE Cable Red R (Red) Black B (Black) White G (Green) Note: The Badger ADE register must be programmed for 6-digit readings for proper operation with a STAR MTU. Badger Read-O-Matic MTU Cable Read-O-Matic Terminals Red + Positive Black - Negative White - Negative Page 24 MTU Cable OER Cable Red R (Red) Black B (Black) White G (Green) Note: The 5-digit Metron OER register must be configured for an additional trailing zero for proper operation with STAR MTUs. MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following American Meter Company meters: AC-175, AL-175, AT-175, AC-250, AL-250, AM-250, AR-250, AT-210/250, AT-350, AL-425, AC-630. Parts Required Ref. # 10 Item Gasket Coupler, MTU Retaining Shaft, MTU MTU, Direct Mount Magnet #8 x 3/8” Combo Panhead Sheet Metal Screw ¼-20 x 1 1/4” Slotted Fillister Head Machine Screw Register Cover #10 x 1” Combo Panhead Sheet Metal Screw 471-2003 - 7/18/2007 Part Number 066-5155E 056-5155E1 056-5155D per project 036-0002 069-080012C4A 069-142040GA 109-7712A 069-100032C3A Quantity Page 25 MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • Phillips screwdriver • Slotted screwdriver Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws that hold it. Discard both the screws and the cover. Step 2 - Remove the register by removing the two screws that hold it. Set the register aside. Discard the screws. Step 3 - Mount the register onto the MTU, fastening the register to the mounting holes shown here with the #8 x 3/8” screws provided. Start one of the two screws into the mounting hole, and then slide the register beneath the screw aligning the wiggler on the register with the MTU coupler. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Use of Power tools is not recommended. Page 26 Then insert the second screw and tighten both screws to a torque not to exceed 3-5 inch-pounds. Note: On some odometer-style registers like the one shown below, slight protrusions on the back of the register assembly can interfere with proper alignment of the register. Should this occur, use a diagonal cutting plier to trim the two wire guides on the MTU to the right of the coupler. Trim these guides as close to flush with the MTU enclosure as possible. (See MTU photo below.) MTU Instruction for American Meter Company Gas Meters Step 4 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 5 – Next, Insert the two ¼-20 x 1 1/4” machine screws through the holes on the MTU as shown here. Half-foot Drive Quarter-foot Drive Step 8 – Now, firmly hand tighten the two screws to 12 to 15 in-lb. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure. Because of this, power tools are not recommended for this procedure. Step 6– Turn the MTU over and place the gasket on the back of the MTU so that it aligns over the two screws. Step 9 - Check the coupling one more time. It should have slight play — it should not bind or turn too freely. Step 7 – Next, position the MTU on the meter. Tighten the two ¼-20 x 1 1/4” mounting screws most of the way, and then rotate the register dials slightly to engage the wiggler on the gas meter. The wiggler must engage with the rear coupler on the MTU as shown in these illustrations. (Coupler shown detached from the MTU for illustration purposes only.) Step 10 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Page 27 MTU Instruction for American Meter Company Gas Meters Step 11 – Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Page 28 Step 12 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR indirect-mount MTU on the following American Meter Company meters: 5B-225, 225. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Ref. # Not Shown Item Gasket Drive Foot Magnet Spyder American Meter 225 Sensor Magnet #8 x 3/8” Combo Panhead Sheet Metal Screw ¼-20 x 2” Slotted Fillister Head Machine Screw MTU, Indirect Mount MTU spacer for pipe or bar mount Not Shown 18″ heavy-duty UV-resistant tie wrap Not Shown 10-32 x 1½″ pan head machine screw 10-32 nut, stainless steel #10 7/16” flat washer, stainless steel Not Shown Not Shown Not Shown 471-2004 - 7/18/2007 Part Number Part of Item 4 Part of Item 4 Part of Item 4 109-7393B 036-0002 069-080012C4A 069-142064HA per project 056-5155K 067-0030 Quantity 069-103248CS 069-3011 069-3004 Page 29 MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • • Cordless drill ⅜”, variable speed, adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver 7/16″ nutdriver or boxwrench Diagonal side cutter Installation Procedure Step 4 - If the meter has a stamped metal right angle drive foot, orient the drive foot of the index to the position of the magnet coupler of the sensor as shown. The index foot should be over the open or flat area of the coupler. It should not engage the elongated slot/hole in the magnet coupler. When properly installed, the magnet coupler will simply push on the outside of the index foot to rotate it. Installing the Sensor Assembly Before installing the Sensor Assembly, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws. Set the clear register cover aside. Discard the screws. Step 2 - Remove the register by removing the two screws. Set the register aside. Discard the screws. Step 3 - If the meter has a stamped metal right angle drive foot (not a round plastic pin), verify that the nylon spacer washers are in place, as shown here. Page 30 Page 2 MTU Instruction for American Meter Company Gas Meters Step 5 - If the meter has a round plastic pin, align the register to the American 225 Meter Adapter. The pin on the register must be in the hole in the coupler, as shown. Make sure the index foot rotates freely. Step 9 - Mount register with adapter and the original plastic cover to the meter. Step 10 - Attach the register and adapter assembly to the meter with the four ¼-20 x 2 fillister head screws. Tighten the screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Step 11 - Replace any anti-tamper, safety, or security hardware onto the cover as required. Step 6 - Place the wire into the channel to the right. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on step 7. Step 7 - Fasten the register to the adapter with the two #8 x 3/8” screws provided. Hand tighten to a torque not to exceed 3-5 inch-pounds. Step 12 - Mount the MTU, following the wiring and mounting guidelines outlined in Publication 471-2000, General Installation and Wiring Guidelines. If necessary, the MTU cable can be extended up to 500 feet. Note: If desired, you can mount the MTU on the supply line using the bar-mounting procedure below. Step 13 – Once installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Bar-Mounting the MTU Step 1 - Thread the tie-wraps into the MTU spacer as shown here. Step 8 - Rotate the adapter arm 180 degrees from the position of the meter indexer. An example is shown. Page 31 MTU Instruction for American Meter Company Gas Meters Step 2 - Attach the spacer to the MTU using the provided screws and washers. Tighten the screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Step 4 - Adjust the MTU as needed and pull the tie wraps tight. Step 5 - Trim off the excess tie wrap, leaving about a ½” tab. Step 3 - Wrap the tie wraps around the bar as needed, pulling the ties around (through the spacer plate) as they are tightened. Page 32 Step 6 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Carson Industries Model 1419-3 or 1419-5 pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item MTU ¼” x 3 ½” Phillips flat-head stainless steel machine screw ¼’ Stainless Keps nut ¼” Stainless flat washer Tools Required To mount the MTU to these Carson pit lids, you will need the following tools and equipment: • • • • • • • Drilling fixture for Model 1419 lids. Safety goggles #3 Phillips driver bit 7/16” Nut driver 17/64” standard drill bit MTU Programmer Cordless Drill 3/8”, variable speed, with adjustable torque settings. 471-2005 - 2/28/2006 Part Number As required for installed meter Source locally Source locally Source locally Quantity Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Page 33 MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Installation Procedure Step 1 - Mount the drilling fixture onto either model of the Carson Pit Lid. The fixture is keyed so that it will align in only one direction. Step 2 - Hold the fixture secure in position on the lid and drill two holes into the lid using the supplied 17/64” drill bit, through the guide holes in the fixture. Step 5 - Insert 2 stainless screws through the holes drilled in the top side of the lid. Step 6 - Turn the lid over and attach the FlatPak as shown below. Note the FlatPak orientation. The front side (with the STAR logo) must be placed against the bottom of the lid. Apply a ¼” stainless steel flat washer to each screw, then apply the ¼-20 stainless steel keps nut to each screw. Step 3 - Remove the fixture from the lid. Step 4 - Countersink the 2 holes using the supplied ¾” 82 degree countersink, only deep enough for the screw heads to be flush or slightly below the surface of the lid. Step 7 - Tighten the hardware with the torque driver. Use the nutdriver or combination wrench to hold the nut if necessary. Tighten hardware just past snug. CAUTION! Use no more than 12-15 in-lbs of torque. Do not over tighten hardware. Page 34 MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Step 8 - Turn the lid over and verify that the heads of the screws are flush or below the lid surface. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 9 – Wire the MTU to the meter, folding and forming wires into valve box as necessary so that they do not interfere with lid locking mechanism and cannot become pinched. Step 10 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. Page 35 MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Intentionally Left Blank Page 36 MTU Instruction for Armor Access Rubber Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to an Armor Access brand rubber composite pit lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item MTU Long Spacers (for pit lid mounting of New Style Flatpak MTUs) #10 x 2 1/2” Phillips Pan Head Type AB Stainless Steel Sheet Metal Screw #10 x 2” Phillips Truss Head Type AB Stainless Steel Sheet Metal Screw Tools Required To mount the MTU to these Armor Access pit lids, you will need the following tools and equipment: • • • Safety goggles #3 Phillips driver bit Cordless Drill 3/8”, variable speed, with adjustable torque settings. 471-2006 - 11/6/2006 Part Number As required for installed meter 056-8150L Quantity 2 per New Style MTU installation 2 per New Style MTU installation 2 per Original Style MTU installation Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Page 37 MTU Instruction for Armor Access Rubber Pit Lids Installation Procedure through the recessed mounting holes as shown. Torque screws to approximately 8 in-lbs. MTU should be snug and flush to the surface of the pit lid. Pit Lid with No Recess Mounting an Original Flatpak STAR MTU to an Armor Access pit lid. Step 1 – If there is a recess on the bottom surface of the pit lid, place the MTU into the recess. If no recess, center the MTU as shown onto the inside surface of the lid. Pit Lid with Recess Pit Lid with No Recess Step 3 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Pit Lid with Recess Step 4 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 2 - Attach the MTU to the pit lid with the 2” stainless sheet metal screws Page 38 MTU Instruction for Armor Access Rubber Pit Lids Mounting a New Flatpak STAR MTU to an Armor Access pit lid. Step 1 – Center the MTU as shown onto the bottom surface of the pit lid. Place plastic spacers under the mounting lugs on the MTU as shown below. Be sure to use the long spacers (Hexagram Part Number 056-8150L). Step 3 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 4 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. Step 2 - Attach the MTU to the pit lid with the 2 ½” stainless sheet metal screws through the 2 mounting holes and the spacers as shown. Torque screws to approximately 8 in-lbs. The MTU should be snug and suspended by the spacers above the bottom surface of the pit lid by approximately ½”. PagePage 39 3 MTU Instruction for Armor Access Rubber Pit Lids Intentionally Left Blank Page 40 MTU Instruction for Invensys Icon MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing FORM 2s and FORM 12S Invensys Icon MTU/Electric Meter Assemblies. Supplies and Tools Required Physical Installation of the ICON Form 2S and Form 12S MTU/Electric Meter Assemblies into compatible meter sockets can be accomplished without the use of tools. Installation Procedure Step 1 – Complete all test procedures required by the local electric utility and verify that the meter socket has been correctly installed and wired. Testing of the meter socket, however, may require specialized equipment. Check with the local electric utility for required testing procedures. WARNING! Be sure to follow all local safety procedures and do not touch the exposed electrical terminals in the meter socket. These terminals carry the full incoming service voltage. Touching these terminals may result in death or serious injury. 471-2007 - 2/28/2006 Page 41 MTU Instruction for Invensys Icon MTU/Electric Meter Assembly Step 2 – (For Form 12S meters only – Skip this step for Form 2S meters) The neutral-blade of the Form 12S meter can be moved. The figure below shows the rear of the meter base with the neutralblade in the factory default, 9 o’clock position (referenced by looking into the meter socket.) e. Replace screws – Place the two screws in the new neutral-blade location. Step 3 – Place the meter/MTU assembly into the meter socket, carefully aligning the contact blades with the corresponding jaws in the meter base. Step 4 – Install a T-bar and /or any seals necessary to meet local requirements. Step 5 – Make a final visual inspection to ensure that the meter/MTU assembly is seated and sealed properly. Step 6 – Installation is now complete, program the MTU using the STAR Programmer Software and your MTU Programmer. The neutral-blade can be moved to the 6 o’clock or 3 o’clock position to fit varying Form 12S meter sockets using a #1 Phillips screwdriver, as follows: a. Locate the configurable neutralblade – On the rear of the meter base, locate the configurable neutral-blade. b. Remove screws – Remove the two screws on either side of the neutral-blade. c. Remove neutral-blade – Remove the neutral-blade from its molded socket. d. Seat neutral-blade – Seat the neutral-blade into the desired location. Note: When replacing the screws, ensure that they are snug, and that the heads are flush with the neutral-blade. Page 42 When programming the integral MTU mounted in this meter, hold the programming coil above the top center of the meter, as shown here. MTU Instruction for STAR Submetering MTUs with Pulse Adapters Purpose & Scope This instruction provides procedures for installing and programmin STAR MTUs equipped with voltage or temperature sensing pulse adapters including the following: 501-7786P, 501-7786T, 501-7786-PP, 501-7786PR, 501-7786PT, 501-7786PT2. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item Submetering MTU with temperature sensing pulse adapter. Part Number 501-7786T Quantity (As required) Submetering MTU with voltage sensing pulse adapter. 501-7786P (As required) Dual-port Submetering MTU with voltage sensing pulse adapters. 501-7786PP Dual-port Submetering MTU with a voltage sensing pulse adapter and a reed switch input. Dual-port Submetering MTU with voltage and temperature sensing pulse adapters. Thermocouple, Type E, 20 gauge 501-7786-PR 071-0850 1 per temperature sensing port. Wire Splice, 3M Scotchlok 314 043-1914 2 per temperature sensing port. Cable Tie, 5.6”, Black, UV 067-0007 3 per temperature sensing port. Pressure Sensitive Hold-downs 067-0051 2 per temperature sensing port. Drywall screws, #6 x 2” Phillips, coarse (for indoor use) Plastic masonry anchors #6 – 12 x 1”, ¼” diameter Source locally Source locally 2 per MTU 471-2008 - 2/22/2008 (As required) (As required) 501-7786-PT (As required) 2 per MTU Page 43 MTU Instruction for STAR Submetering MTUs with Pulse Adapters Tools Required • • • • Crimping Pliers for Insulation Displacement Connectors (IDCs) Wire cutters/stripper Cleaner (non-residue type) and rag/paper towel Stapler for ¼” wire and cable (Arrow T-25M) Introduction STAR Submetering MTUs with Pulse Adapters provide accurate, highresolution data for point-of-use allocation billing for a wide variety of HVAC appliances. Note: Only on-off devices are suitable for application of these pulse adapter MTUs. • Voltage Sensing Pulse Adapters can be applied to gas appliances that are controlled by a standard 24VAC gas valve. • Temperature Sensing Pulse Adapters can be applied to gas water heaters, fireplaces and other HVAC appliances that do not have 24 VAC controls These units produce an extremely accurate pulse at a rate of 10 seconds per pulse (0.1 Hz or 6 pulses per minute) when the specified input conditions (voltage or temperature) are met. These pulses are counted by the MTU which periodically transmits the accumulated count to nearby Data Collector Units. Note: The submetering MTUs discussed in this instruction are for indoor use (dry locations) only. Page 44 Connecting Voltage Sensing (Type P) Inputs Voltage Sensing (Type P) inputs are provided with a 2-wire connection that can be wired across (in parallel with) the 24 VAC gas valve solenoid of the furnace or other HVAC appliance. Simply connect the RED and BLACK wires across the gas valve solenoid. Once connected in this way, a voltage of between 18 and 30 VAC applied across the valve solenoid will cause the MTU to begin pulsing and recording usage. CAUTION Do not connect the white wire of the MTU when connecting voltage sensing inputs. Cut the white wire back to the cable jacket. Connecting the white wire may damage the MTU. Typical Furnace Application This procedure covers a typical installation of a voltage/current sensing pulse adapter on a gas furnace. Step 1 - Turn the furnace setting to "Pilot" so that it will not operate during the installation process. Step 2 - Mount the MTU on a wall, joist or other convenient location near the furnace to be monitored. Run the cable from the MTU to the gas valve solenoid of the device. Trim or extend the MTU cable, as needed. Care must be taken to protect the cable from damage by hot surfaces or sharp sheet metal. Use insulated staples or cable ties as needed. Note: Be sure to follow all General Mounting & Wiring Guidelines outlined in Publication 471-2000. MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 3 – Connect the RED and BLACK leads from the MTU across (in parallel with) the 24 VAC control input to the gas valve. On most gas valves, these connections can be made at the terminals on the gas valve solenoid. Step 4 – Program the MTU using the MTU Programmer as outlined in the Programming section of this document. Step 5 - Return the furnace setting to "Run". Connecting Temperature Sensing (Type T) Inputs Temperature Sensing (Type T) inputs are provided with a two wire connection designed to be directly connected to a Type E thermocouple that is supplied with the temperature sensing MTU. When the thermocouple reaches a temperature of 110◦ - 130◦ C (230◦ - 265◦ F), the MTU will begin pulsing and recording usage. ● The VIOLET lead is the positive side and must be connected to the RED wire of the MTU Input Cable. ● The RED lead of the thermocouple is the negative side and must be connected to the BLACK wire of the MTU input cable. Typical Hot Water Heater Application This procedure covers a typical installation of a temperature sensing pulse adapter on a gas hot water heater. Step 1 - Turn the hot water heater setting to "Pilot" so that the heater will not operate during the installation process. Step 2 - Insert the copper thermocouple sleeve into the space under the draftinducer cone at the top of the water heater. Position the tip of the thermocouple INTO the center of the flue as shown below. ( ½ to ¾ of an inch) By convention, Type E thermocouples are supplied with two color-coded leads. Page 45 MTU Instruction for STAR Submetering MTUs with Pulse Adapters Gently shape the copper sleeve on the thermocouple so that it does not contact the metal surface of the draft hood or the top of the hot water tank as shown in the side view illustration. Step 3 - Clean the surface area of the hot water heater under the thermocouple. Dry thoroughly. Locate and mount the two pressure sensitive hold-downs in the cleaned area. Locate one hold-down at the approximate center of the copper sleeve and the other at the very end so that they firmly anchor the thermocouple. Thread a cable tie through the slot in the hold-downs to fasten the thermocouple. If necessary, gently form the copper sleeve to facilitate mounting while insuring that the tip of the thermocouple is in the center of the flue and the copper sleeve is not in contact with metal surfaces. Step 4 - After the thermocouple sleeve is secure, route the thermocouple wire near the inlet or outlet water pipe. Use the third cable tie to secure the thermocouple wire to the pipe as a strain relief. Step 5 - Mount the MTU on a wall, joist or other convenient mounting location using two screws. Run the cable from the MTU to the end of the thermocouple wire. Trim excess MTU cable, as needed. Care must be taken to protect the cable from damage by hot surfaces or sharp sheet metal. Use insulated staples or cable ties as needed. Note: Be sure to follow all General Mounting & Wiring Guidelines outlined in Publication 471-2000. Step 6 - Splice the MTU wire to the thermocouple wire using the two IDCs provided. Page 46 ● Connect the VIOLET thermocouple wire to the RED MTU wire. ● Connect the RED thermocouple wire to the BLACK MTU wire. Do not remove the insulation from either the MTU wires or the thermocouple wires; the IDC is designed to pierce the insulation. Step 7 – Program the MTU using the MTU Programmer as outlined in the Programming section of this document. Step 8 - Return the hot water heater setting to "Run". Typical Burner/Fireplace Application This procedure covers a typical installation of a temperature sensing pulse adapter on a burner or fireplace. Step 1 - Set burner or fireplace control so that the appliance does not come on during installation. Step 2 - Fasten thermocouple so that the tip is near, but not in, the flame when the gas is burning. Use metal clamps or wire fasteners to secure the thermocouple. (NOTE: Clamps or wire fasteners are not provided by Hexagram. Individual installation conditions will determine the type of fastener to be used.) A location must be selected that allows the thermocouple tip to reach at least 130° C (400° F). However, the tip temperature must not exceed 350° C (660° F). If a pilot light is present, keep the thermocouple at least 6" away from the pilot flame. Step 3 - Route thermocouple wire away from the appliance. MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 4 - Mount the MTU on a wall, joist or other convenient mounting location well away from the heat source using two screws. CAUTION The MTU must be located away from the appliance and ONLY in a location that remains at room temperature. Run the cable from the MTU to the end of the thermocouple wire. Trim excess MTU cable, as needed. Care must be taken to protect the cable from damage by hot surfaces or sharp sheet metal. Use insulated staples or cable ties as needed. Note: Be sure to follow all General Mounting & Wiring Guidelines outlined in Publication 471-2000. Step 5 - Splice the MTU wire to the thermocouple wire using the IDCs provided. Use a cable tie(s) to provide strain relief for the wiring. ● Connect the VIOLET thermocouple wire to the RED MTU wire. ● Connect the RED thermocouple wire to the BLACK MTU wire. Do not remove the insulation from either the MTU wires or the thermocouple wires; the IDC is designed to pierce the insulation. Step 6 - Secure the MTU wire. Verify that the MTU cable does not run near the burner and does not enter any region where the temperature will exceed 70° C (160° F). Step 8 - Reset the burner or fireplace control so that the appliance can run. Programming Note: The 501-7786PT2 MTU requires Star Programmer Software version 6.0.0 and meter table version 3.85 or higher. Step 1 - Turn on the Psion MTU Programmer by pushing On/Esc. Note: A “Communication Error” message may occur: ● If an attempt is made to read and/or program the MTU and the MTU is receiving input from the gas appliance to which it is wired. OR ● If an attempt is made to read and/or program the MTU and there is a wiring error in the wiring between the MTU and the thermocouple. Verify that the gas appliance is off and that the thermocouple is correctly connected. Step 2 - Highlight the STAR icon (in the Psion desktop screen) using the left/right arrow keys. Press Enter. At this point, the STAR software loads along with the Meter table, Database table, and Appointment table. If these are loading for the first time, it may take several minutes. When complete, the serial number verification screen will appear. Step 7 – Program the MTU using the MTU Programmer as outlined in the Programming section of this document. Page 47 MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 3 - A screen asking if the operator wishes to change the Psion’s serial number is displayed. NOTE: - At midnight, the software automatically resets to require re-entry of the log-on information. This is a security measure in case the Psion is lost or stolen. Step 5 - The “Set Time & Date” screen is displayed. This number should match the last four digits of the serial number etched on the back of the Psion. Typically, select N to accept the serial number as is. Pressing Y will take the operator to a screen where the serial number can be changed, if necessary. Step 4 – You are now at the logon screen. Log on by entering the following information: a - Operator: The Psion operator file will accommodate up to 99 separate operator user codes. This user code is “Install” followed by an assigned operator code. Enter your assigned code number immediately after “Install” without any spaces. Press Enter when finished. Example: Install6 b - Enter the password. This password will typically be assigned by a project manager. Press Enter when finished. Example: Acme Note: Use the DEL key to backspace and make corrections. Page 48 Make any corrections to the time and date as required. Press Enter when finished. It is not necessary to reset the time if it is less than 5 minutes off. Step 6 - The main menu of the STAR software is now displayed. At the top of the screen the installer identification is displayed. The bottom of the screen has instructions for navigation. Most of the screens in the STAR software have this instruction feature at the bottom of the screen. The menu consists of options you can select, as described in the following table. The actual options you see will depend on the configuration of your system. Some choices may not be available on your system. MTU Instruction for STAR Submetering MTUs with Pulse Adapters STAR Programming Software – Main Menu Choices Menu Item Add MTU Add MTU And Replace Meter Function Select this item when a new MTU is being connected to an existing meter. Select this item when a new MTU is being added and the current meter is being replaced. Add MTU And Meter Select this item when a new MTU and meter are being installed where no previous equipment existed. Select this when an existing MTU is being replaced and no meter changes are occurring. Select this when an existing meter is being replaced and no MTU changes are occurring. Select this when an existing MTU and meter are being replaced. Replace MTU Replace Meter Replace MTU And Meter Reprogram MTU Read MTU Turn MTU Off Operator log-off About STAR Programmer Use this selection when reprogramming an MTU with no equipment changes. Select this to read the current configuration information from an MTU. Select this to turn an MTU off, causing its transmissions to stop. To log off the STAR Programmer software, select this option and press Enter. Choose this menu option if you need to contact a customer service representative at Hexagram. To select the desired programming mode, use the up/down arrow keys to scroll to the mode on the STAR program Main Menu screen and press Enter. Follow the instructions on the screen and enter the requested data. At any time before installation data is actually written to the MTU, the operator can cancel out of the programming operation by pressing On/Esc. The operator will be required to enter a reason as to why programming was cancelled. Once programming has been successfully completed, the MTU will be turned on and will Start transmitting its wake up data to the DCU every five minutes. It will transmit for less than a second of every five minutes for forty-five minutes. Page 49 MTU Instruction for STAR Submetering MTUs with Pulse Adapters Intentionally Left Blank Page 50 MTU Instruction for AMCO and ABB Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to AMCO and/or ABB water meters (all sizes) equipped with Invision, Scancoder, RS Pulser, Type A Industrial Pulser, or AMCO Digital registers and with the AMCO/ABB V100/PSMT meter, and the S130/5UM hot and cold water meters. Invision Scancoder MTU Cable Invision Register Red G (Green) Black B (Black) MTU Cable Scancoder Register White R (Red) Red G (Green) Black B (Black) White R (Red) Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. 471-2009 - 2/28/2006 Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. Page 51 MTU Instruction for AMCO and ABB Water Meters b. Water Meter with Integral Cable - If the water meter is supplied with an integral cable and a cable-to-cable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Type A Industrial Pulser Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. RS Pulser MTU Cable Type A Industrial Pulser Register Red + Positive Black - Negative White - Negative AMCO Digital Register MTU Cable RS Pulser Register Red R (Red) Black B (Black) White B (Black) No Connection G (Green) Page 52 MTU Cable AMCO Digital Register Red R (Red) Black B (Black) White B (Black) No Connection G (Green) MTU Instruction for AMCO and ABB Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. S130/5UM Hot Water Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. V100/PSMT MTU Cable S130/5UM Cable Red Brown Black White White White S130/5UM Cold Water MTU Cable V100/PSMT Cable Red Red Black Blue White Blue No Connection Black No Connection Yellow MTU Cable S130/5UM Cable Red Brown Black White White White Page 53 MTU Instruction for AMCO and ABB Water Meters Intentionally Left Blank Page 54 MTU Instruction for Neptune and Schlumberger Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Neptune and/or Schlumberger water meters (all sizes) equipped with ARB-V, Auto/ProRead, or E-Coder PLUS registers. ARB-V or Auto/ProRead E-Coder PLUS MTU Cable ARB-V or Auto/ProRead Register Red B (Black) Black G (Green) White R (Red) Notes: • Auto/ProRead registers must be programmed by the manufacturer for 3-wire mode. 471-2010 - 8/6/2006 MTU Cable E-Coder PLUS Register Red B (Black) Black G (Green) White R (Red) Notes: • E-Coder Plus registers require a special purpose NTG MTU (Hexagram Part Number 501-11586D) to make use of the E-Coder’s advanced leak, tamper and reverse flow detection capabilities. Page 55 MTU Instruction for Neptune and Schlumberger Water Meters Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. NTG MTU Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Over-tightening the screw can stress and possibly fracture the wire. b. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. Page 56 The NTG MTU is a special purpose MTU designed specifically to support the advanced capabilities of Neptune’s ECoder solid-state register. This MTU provides the following special functions when coupled to an E-Coder Plus register and properly programmed. • 8-Digit Readings – The NTG MTU reads and transmits the full 8-digit reading from the E-Coder at the programmed read interval, typically every 12 hours. A full range of read intervals are supported, including temporary read intervals for temporary monitoring purposes. MTU Instruction for Neptune and Schlumberger Water Meters • Alarm Polling – The NTG MTU also automatically polls (reads) the E-Coder alarm indicators every 15 minutes. This happens automatically, independently of the standard read interval mentioned above. If the NTG MTU detects any change in the alarm status of the E-Coder Plus register, an alarm transmission is generated immediately, reporting the change in alarm status to the DCUs. Compatibility with Neptune E-Coder Registers Hexagram’s NTG MTU is compatible with Neptune E-Coder Plus solid state registers revision 05.98 or higher. Checking E-Coder Revision Level To check the revision level of an E-Coder register, use your hand to block all light from striking the E-Coder’s solar cell for approximately 20 seconds. Then, remove your hand allowing light to strike the solar cell. The E-Coder’s display will briefly flash all 8s, and then reveal a display like that shown below. The four digit number at the right of the display is the revision level. In the illustration above, the revision level shown is 05.98. Compatibility with Neptune ARB-V and ProRead Registers Upon initial installation, an NTG MTU can also be used with meters equipped with Neptune’s ARB-V or ProRead registers. These are standard absolute encoder registers without the advanced capabilities of the E-Coder register. When used with ARB-V or ProRead registers, the NTG MTU operates in standard mode, providing 6-digit readings and no specialized alarm polling. Note: Auto/ProRead registers must be programmed by the manufacturer for 3wire mode. It is important to note that once an NTG MTU is programmed to function in the advanced mode with an E-Coder register, it can no longer be returned to standard operation. To caution the user, the display shown below will appear when first programming an NTG MTU for use with an E-Coder: CAUTION! Once an NTG MTU is programmed for use with an E-Coder it can no longer be used with other (non-E-Coder) registers. Page 57 MTU Instruction for Neptune and Schlumberger Water Meters Once the user selects Yes on the above screen and successfully completes programming the NTG MTU for use with an E-Coder Plus register, the NTG MTU can no longer be used with an ARB-V or ProRead register. From this point forward, only E-Coder meter types will be available for selection when programming this NTG MTU. Error Codes When an E-Coder meter type is selected while programming an NTG MTU with the MTU Programmer, the MTU attempts to communicate with the register using a special protocol that reads the status of the E-Coders leak, tamper and reverse flow detection indicators. If the MTU cannot successfully communicate with the register, an error code will be displayed on the MTU Programmer, as shown below. Pressing Enter in response to this display will display the current settings for the MTU, including the error code, as shown below. Page 58 This error indicates one of the following problems: • Attempting to use an E-Coder meter type with a register that is not an E-Coder. • A defective E-Coder register. • Improper wiring between the NTG MTU and the E-Coder. (Refer to Publication 471-2110 for E-Coder wiring information.) MTU Instruction for Sensus and Invensys Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Sensus and/or Invensys water meters (all sizes) equipped with ECR or ICE registers. ECR or ICE Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. MTU Cable Sensus/Invensys Register Red R (Red) Black B (Black) White G (Green) Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Application Notes • The 8-digit Sensus ICE Register must be programmed to deliver 6 consecutive digits of reading information for proper operation with STAR MTUs. 471-2011 - 2/28/2006 a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. b. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. Page 59 MTU Instruction for Sensus and Invensys Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Page 60 Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for Hersey Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Hersey water meters (all sizes) equipped with Translator or ER2 registers. Translator ER2 MTU Cable Hersey Register Red R (Red) Black B (Black) White G (Green) MTU Cable ER2 Cable Red R (Red) Black B (Black) White G (Green) Supplies and Tools Required Installation Procedure See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Application Notes • The Hersey Translator Register must be programmed for 6-digit readings for proper operation with STAR MTUs. 471-2012 - 2/28/2006 Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. Page 61 MTU Instruction for Hersey Water Meters a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. b. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 62 MTU Instruction for Badger Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Badger water meters (all sizes) equipped with Read-O-Matic, RTR, or ADE registers. RTR ADE MTU Cable RTR Cable MTU Cable ADE Cable Red R (Red) Red R (Red) Black B (Black) Black B (Black) White G (Green) White G (Green) Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Application Notes • Some Badger RTR registers may be provided with only a black wire and a white wire with a shield. For this variation, Trim the shield off and connect as shown below. MTU Cable RTR Cable Black B (Black) White B (Black) Red W (White) No Connection White-Shield 471-2013 - 2/28/2006 • The Badger ADE register must be programmed for 6-digit readings for proper operation with a STAR MTU. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. a. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for Page 63 MTU Instruction for Badger Water Meters outdoor (moisture applications) to seal the individual connections. Read-O-Matic Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. b. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 64 MTU Cable Read-O-Matic Terminals Red + Positive Black - Negative White - Negative MTU Instruction for MLOG Sensors Purpose & Scope This instruction provides wiring information for use in connecting a STAR encoder-type MTU to a Flow Metrix MLOG Sensor. Use gel-filled wire splices designed for outdoor applications to seal the individual connections. For pit installations, seal and enclose the three individual connections using a direct burial splice kit to complete the waterproof splice. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 – Mount the MLOG Sensor in accordance with the manufacturer’s instructions. Step 2 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Note: If the MLOG sensor is connected to a dual port MTU along with a meter, the meter should be connected to port 1 and the MLOG Sensor should be connected to port 2. For a dual port MTU, port 1 is the black jacketed cable and the port 2 cable has a grey jacket. Step 4 – Make a final visual check of the wiring from the MTU to the MLOG Sensor. Verify that the cable routing is neat, secure and professional. Step 5 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. During programming, select “MLOG LEAK DETECTOR” as the meter type and set the read interval to 6 hours. Note: The read interval for the MTU connected to the MLOG Sensor MUST be set for 6 hours. Step 3 – Connect the three wires from the MTU cable to the three wires of the MLOG cable as shown in the following table. MTU Cable MLOG Sensor Red R (Red) Black B (Black) White G (Green) Page 65 MTU Instruction for MLOG Sensors Intentionally Left Blank Page 66 MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Purpose & Scope This instruction provides a procedure for use in connecting a STAR MTU to an IMAC Pulsimatic Transmitter and installing the Pulsimatic Transmitter on a Rockwell/Equimeter Model 750-10000 Intermediate or Large Capacity Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item IMAC Pulsimatic Transmitter for Rockwell/Equimeter Model 750-10000 Intermediate and Large Capacity Diaphragm Gas Meters. One pulse per revolution. IMAC Mounting Hardware - Rockwell Index Cover without security cap bosses NOTE: This item is needed only if the existing Index Cover has the security cap bosses. If the existing Index Cover does not have the security cap bosses, it can be reused. MTU, Reed/Weigand Pulse Part Number 035-8150A Quantity 069-8150F 056-5155D 501-6327R1 Any STAR MTU with an available Type R Port may be used for this installation. 471-2015 - 2/28/2006 Page 67 MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Tools Required • • • • • Slotted (Flat-blade) screwdrivers in the following blade tip width sizes: 5/32” narrow-blade, 9/32”, and ½”. If desired, use torque driver, 10 foot-lb. range. ½” combination (hand) wrench or socket/ratchet wrench. A torque wrench is recommended (30 inchlb. range). 8” adjustable wrench. 5/16-18 blind-hole (bottoming) tap and mating size T-handle. Canned compressed air. Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 2 - When wiring to the IPT, support the IPT off of the work surface on the outside (topside) of its base so that pressure is not applied to the center drive shaft. Remove the cable clamp (screw) from inside the base. Step 3 – Trim the stripped ends of the MTU cable to ¼” or slightly shorter. When inserted into the terminal block, only a small amount of bare wire should be visible. Bare wire should not extend beyond the walls of the terminal block. This will present a shorting potential. Step 4 – Feed the MTU input cable through the sealtight strain relief in the base of the IPT. Loop the cable so that stripped ends of the wires can be easily inserted into the terminal block screws. The screws should already be open enough. Place cable clamp over the wire as shown. There are two parts to this procedure. First, the MTU must be wired to the IMAC Pulsimatic Transmitter (IPT). Once this is complete, you can then install the Pulsimatic Transmitter onto the Rockwell gas meter. Wiring the MTU to the Pulsimatic Step 1 – Unpack all of the components required to install the IPT. This should include the IPT itself, gasket and a hardware kit that includes (2 each) brass threaded rods, stainless flat-washers and hex nuts. Step 5 – Insert the BLACK and WHITE wires into the COM terminal screw. Tighten the screw. Step 6 – Insert the RED wires into the NC BLU terminal screw. Tighten the screw. Page 68 MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 7 – Pull most of the slack out of the cable (leave a slight amount of slack) and reattach cable clamp as shown below. DO NOT pull the cable taut. Installing the Pulsimatic Transmitter Step 1 – If necessary, remove tamper seals that cover the index cover screws. Loosen and remove screws securing the index cover. You may discard these screws as they will not be re-used. Remove the cover. If the cover has the tamper seal bosses, this cover will be need to be replaced. Step 8 – Tighten the nut on the sealtight strain relief. You will need to tighten the nut almost fully down (as shown) before it will bite on the MTU cable. Step 9 – Check that all wired terminal block screws are tight. Step 10 – Depending on the installation location, you may be able to mount the MTU at this time. During installation, the IPT body should be supported so as not to hang (apply tension) on the MTU cable. During the installation, do not allow the heavier body of the IPT to suddenly jerk the MTU cable as this could potentially damage the cable internally. Step 2 – Loosen and remove the screws securing the index to the index plate. Save these screws as they will be reused. Remove the index and set aside. Step 11 – Install the MTU into its intended location per the recommended procedure found in the standard Hexagram MTU installation manual. Page 69 MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 3 – If the index cover screws were difficult to remove, the threads in the index plate may need to be cleaned out before installing the hardware that retains the IPT. Use the blind-hole tap to carefully clean out/ clean up the threads of the (2) cover holes. Blow out the holes with compressed (canned) air. NOTE: It is not necessary to clean the index mounting-hole threads as these holes are not reused. Step 6 – Place the IPT (middle set of holes) over the mounting studs. Make sure that the IPT drive pin engages the fork of the meter drive foot. Step 7 – Mount the register onto the base of the IPT using the same screws that originally secured the register to the index plate (meter head). The drive foot of the index must engage the fork of the IPT drive shaft. Tighten/torque the screws to approximately 4-5 ft-lb. Step 4 – Thread the (full thread) ends of the securing studs (2) into the index cover screw holes of the index plate. Lightly snug the studs by grasping them by the flat that is machined into the top of the stud. Apply the gasket over the studs as shown. NOTE: If the index cover that was removed has the security cap boss extensions, this cover will need to be replaced with an index cover without the security cap bosses. Step 5 – Before setting the IPT over the mounting studs, you must align the shaft drive pin of the IPT so that it will engage inside the fork portion of the meter drive foot. Page 70 Step 8 – Although not necessary, it may be desired to keep water or dirt from collecting in the unused corner mounting holes. If closing them is desired, use a permanent outdoor rated non-shrinking putty or caulk such as an RTV. MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 9 – Place the index cover onto the studs. It will fit over the index one way only. Apply a flat washer and nut onto each stud. Snug, and then tighten these nuts an additional ½ to ¾ turn maximum. The finished torque value is 25 – 30 inchlb. Step 10 – Install Wire/Lead security seals if desired. Installation is complete. Page 71 MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Intentionally Left Blank Page 72 MTU Instruction for American Model AL800-AL5000 Gas Meters Purpose & Scope This instruction provides a procedure for use in connecting a STAR MTU to an IMAC Pulsimatic Transmitter and installing the Pulsimatic Transmitter on an American Model AL800-AL5000 Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item IMAC Pulsimatic Transmitter for American Models AL800AL5000 Commercial and Industrial Diaphragm Gas Meters. One pulse per revolution. Long shaft. IMAC Mounting Hardware - American MTU Part Number 035-8150B Quantity 069-8150G 501-6327R1 Any STAR MTU with an available Type R Port may be used for this installation. 471-2016 - 2/28/2006 Page 73 MTU Instruction for American Model AL800-AL5000 Gas Meters Tools Required • Slotted (Flat-blade) screwdrivers in the following blade tip width sizes: 5/32” narrow-blade, 9/32”, and ½”. • ½” combination (hand) wrench or socket/ratchet wrench. A torque wrench is recommended (60 inch-lb. range). • 8” adjustable wrench. • 18-18 blind-hole (bottoming) tap and mating size T-handle. • Canned compressed air. Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure There are two parts to this procedure. First, the MTU must be wired to the IMAC Pulsimatic Transmitter (IPT). Once this is complete, you can then install the Pulsimatic Transmitter onto the American gas meter. Step 2 - When wiring to the IPT, support the IPT off of the work surface on the outside (topside) of its base so that pressure is not applied to the center drive shaft. Remove the cable clamp (screw) from inside the base. Step 3 – Trim the stripped ends of the MTU cable to ¼” or slightly shorter. When inserted into the terminal block, only a small amount of bare wire should be visible. Bare wire should not extend beyond the walls of the terminal block. This will present a shorting potential. Step 4 – Feed the MTU input cable through the sealtight strain relief in the base of the IPT. Loop the cable so that stripped ends of the wires can be easily inserted into the terminal block screws. The screws should already be open enough. Place cable clamp over the wire as shown. Wiring the MTU to the Pulsimatic Step 1 – Unpack all of the components required to install the IPT. This will generally include the IPT itself, gasket and a hardware kit that includes (2 each) brass threaded rods, stainless flatwashers and hex nuts. Step 5 – Insert the BLACK and WHITE wires into the COM terminal screw. Tighten the screw. Step 6 – Insert the RED wires into the NC BLU terminal screw. Tighten the screw. Page 74 MTU Instruction for American Model AL800-AL5000 Gas Meters Step 7 – Pull most of the slack out of the cable (leave a slight amount of slack) and reattach cable clamp as shown below. DO NOT pull the cable taut. Step 8 – Tighten the nut on the sealtight strain relief. You will need to tighten the nut almost fully down (as shown) before it will bite on the MTU cable. Step 9 – Check that all wired terminal block screws are tight. Step 10 – Depending on the installation location, you may be able to mount the MTU at this time. During installation, the IPT body should be supported so as not to hang (apply tension) on the MTU cable. During the installation, do not allow the heavier body of the IPT to suddenly jerk the MTU cable as this could potentially damage the cable internally. plate assembly. You may discard these screws as they will not be re-used. Remove the index plate assembly from the top of the meter. Do not disassemble the index cover from the index plate. Step 2 – If the index plate mounting screws were difficult to remove, the threads in the meter head (handhole plate) may need to be cleaned out before installing the hardware that will retain the IPT and index plate stack. Use the blindhole tap to carefully clean out/ clean up the threads of the (2) cover holes. NOTE THAT THESE THREADS ARE #18-18. MAKE SURE TO USE THE PROPER TAP. Blow out the holes with compressed (canned) air. Step 11 – Install the MTU into its intended location per the recommended procedure found in the standard Hexagram MTU installation manual. Installing the Pulsimatic Transmitter Step 1 – If necessary, remove tamper seals from any of the 4 screws that secure the index plate. Loosen and remove the screws securing the index Page 75 MTU Instruction for American Model AL800-AL5000 Gas Meters Step 3 – Place the adapter plate contained in the installation parts onto the head of the meter with the ear holes aligned over the index plate mounting holes of the meter head. The embossed “AL800-AL5000” on the adapter plate is oriented to the front of the meter. Step 4 – AFTER PLACING THE APAPTOR PLATE, Thread the (18-18 thread) ends of the securing studs (4) into the index cover screw holes of the index plate. Lightly snug the studs by grasping them by the flat that is machined into the top of the stud. Page 76 Step 5 - Apply the seal plate over the studs. Step 6 – Before setting the IPT over the mounting studs, you must align the shaft drive pin of the IPT so that it will engage inside the fork portion of the meter drive foot. MTU Instruction for American Model AL800-AL5000 Gas Meters Step 7 – Place the IPT (4 corner holes) over the mounting studs. Make sure that the IPT drive pin engages the fork of the meter drive foot. Step 10 – Install Wire/Lead security seals if desired. Installation is complete. Step 8 – Before mounting the index plate assembly, the drive foot of the index must engage the fork of the IPT drive shaft. Mount the index plate assembly onto the base of the IPT over the same (4) corner studs. Step 9 – Complete the assembly by securing the index plate onto the studs, with the supplied (4) flat washers and nuts. Tighten these nuts a finished torque of 60 inch-lb. (5 ft-lb.). Page 77 MTU Instruction for American Model AL800-AL5000 Gas Meters Intentionally Left Blank Page 78 MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Sprague/Schlumberger/Actaris Model 175, 250 or 400 and 400A (slant-face) Gas Meter. Parts Required Item MTU, Bracket Direct Mount, for Sprague 175, 250 and 400 #10-24 x 3/8” Slotted Fillister Head Machine Screw Wheel/Magnet Assembly Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • Safety goggles #1 and #2 Phillips screwdrivers #1 and #2 Slotted screwdrivers 5/32” diameter medium grit tapered round file Metal nibbler tool, 1/8” cut Small, diagonal plastic cutting pliers 471-2017 - 2/28/2006 Part Number 501-8150H-A or 501-8150HD5-A 069-102412HA 109-7126A Quantity See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear index cover. Note: Early slant-face Sprague gas meters were equipped with a cast aluminum framed index cover held in place by two screws. Later models are equipped with a plastic index cover held in place by three screws. This procedure can be used with either style. Page 79 MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Step 1 – Remove the clear index cover from the meter by removing the screws that hold it. The clear index cover and index cover screws will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. hooking the two tabs on the bracket behind the heads of the index mounting screws. Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the Index aside until later. The screws that held the index to the meter can be discarded. Step 3 – Remove the drive foot from the meter drive shaft by unthreading it counterclockwise. The drive foot will not be reused and can be discarded. Then, thread the magnet wheel clockwise onto the shaft. Tighten the magnet wheel until snug to the end of the threads on the drive shaft. CAUTION! Be careful not to cross-thread the magnet wheel when installing it on the meter drive shaft. Cross-threading can cause misalignment of the magnet wheel which in turn can cause binding or erratic performance. Step 4 – Thread the two #10-24 x 3/8” machine screws provided about one full turn into the index mounting holes. Step 5 – Place the MTU bracket assembly into position on the meter, Page 80 Step 6 – Replace the index by hooking the two tabs on the index behind the heads of the index mounting screws. Insure that the drive foot on the index will be driven by the pin on the magnet wheel as it rotates. Several styles of indexes and index drive mechanisms may be encountered. Use the photos below as a guide. Note that on indexes with a slotted drive foot, it is intended that the pin on the magnet wheel engages the slot on the drive foot. Brass Index with Slotted Drive Foot MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Brass Index with Offset Drive Foot Step 8 – Notch the index cover to allow the sensor wire to exit through the bottom left edge. On the clear plastic index cover, you can remove (cut away) the inner tab from the molded drain opening at on the bottom left edge of the cover. Plastic Index with Metal Drive Foot Position clear index cover on meter head and route sensor cable though notch. Step 7 – Route the sensor wire so that it does not interfere with the magnet wheel or the index gears. Hand tighten index mounting screws. Gently move the 2-foot hand to check for some free play to insure that the register is not binding up. NOTE: If the meter is equipped with a cast aluminum framed index cover, enlarge the drain hole at the bottom left edge of the cover to approximately 5/32” using a metal nibbler and/or tapered file. Clean up any sharp edges with the tapered file before mounting the index cover. Page 81 MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Step 9 – Secure MTU bracket assembly and the clear index cover to the meter head using the three screws that originally held the clear index cover. Tighten index cover screws. Step 10 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Step 11 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 82 MTU Instruction for Lancaster Model 250 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Lancaster Model 250 (slant-face) Gas Meter. Parts Required Item MTU, Bracket Direct Mount, for Lancaster 250 #10-24 x 3/8” Slotted Fillister Head Machine Screw Wheel/Magnet Assembly Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • Safety goggles #1 and #2 Phillips screwdrivers #1 and #2 Slotted screwdrivers 5/32” diameter medium grit tapered round file Metal nibbler tool, 1/8” cut Small, diagonal plastic cutting pliers Part Number 501-8150H-B or 501-8150HD5-B 069-102412HA 109-7126A Quantity complete list of recommended tools and supplies for MTU Installation. Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear index cover. Step 1 – Remove the clear index cover from the meter by removing the two screws that hold it. The clear index cover and index cover screws will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. See Publication 471-2000, General Installation and Wiring Guidelines for a 471-2018 - 2/28/2006 Page 83 MTU Instruction for Lancaster Model 250 Gas Meters Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the Index aside until later. The screws that held the index to the meter can be discarded. Step 3 – Remove the drive foot from the meter drive shaft by unthreading it counterclockwise. The drive foot will not be reused and can be discarded. Then, thread the magnet wheel clockwise onto the shaft. Tighten the magnet wheel until snug to the end of the threads on the drive shaft. CAUTION! Be careful not to cross-thread the magnet wheel when installing it on the meter drive shaft. Cross-threading can cause misalignment of the magnet wheel which in turn can cause binding or erratic performance. Step 4 – Thread the two #10-24 x 3/8” machine screws provided about one full turn into the index mounting holes. Step 5 – Place the MTU bracket assembly into position on the meter, hooking the two tabs on the bracket behind the heads of the index mounting screws. Page 84 Step 6 – Replace the index by hooking the two tabs on the index behind the heads of the index mounting screws. Insure that the drive foot on the index will be driven by the pin on the magnet wheel as it rotates. Several styles of indexes and index drive mechanisms may be encountered. Use the photos below as a guide. Note that on indexes with a slotted drive foot, it is intended that the pin on the magnet wheel engages the slot on the drive foot. Brass Index with Slotted Drive Foot MTU Instruction for Lancaster Model 250 Gas Meters Brass Index with Offset Drive Foot Step 9 – Secure MTU bracket assembly and the clear index cover to the meter head using the two screws that originally held the clear index cover. Tighten index cover screws. Step 10 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Step 11 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Plastic Index with Metal Drive Foot Step 7 – Route the sensor wire so that it does not interfere with the magnet wheel or the index gears. Hand tighten index mounting screws. Gently move the 2-foot hand to check for some free play to insure that the register is not binding up. Step 8 – Next, create an exit notch for the sensor wire by using a nibbler or plastic cutting plier to add a notch approximately 5/32” in diameter to the bottom left edge of the clear index cover. Do not interfere with the drain hole already molded into the clear index cover. Clean up the edges of the notch using a round tapered file. Then position clear index cover on meter head and route sensor cable though notch. Page 85 MTU Instruction for Lancaster Model 250 Gas Meters Intentionally Left Blank Page 86 MTU Instruction for Lancaster Model 175 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Lancaster Model 175 (slant-face) Gas Meter. Parts Required Item MTU, Bracket Direct Mount, for Lancaster 175 #6-32 x ¼” Phillips Panhead Machine Screw #6 Flat Washer (precision thickness) Wheel/Magnet Assembly Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • Safety goggles #1 and #2 Phillips screwdrivers #1 and #2 Slotted screwdrivers 5/32” diameter medium grit tapered round file Metal nibbler tool, 1/8” cut Small, diagonal plastic cutting pliers 471-2019 - 2/28/2006 Part Number 501-8150H-C or 501-8150HD5-C 069-063208AA 069-2648 109-7126A Quantity See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear index cover. Page 87 MTU Instruction for Lancaster Model 175 Gas Meters Step 1 – Remove the clear index cover from the meter by removing the two screws that hold it. The clear index cover and index cover screws will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. Step 4 – Place the MTU bracket assembly into position on the meter. Use an index cover screw to temporarily hold the MTU bracket assembly in position. Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the index aside until later. The screws that held the index to the meter can be discarded. Route the sensor wire around the righthand index-mounting post then back and under the finger hook so that it does not interfere with the magnet wheel or the index gears. Step 5 – Reattach the index to the meter using the screws and washers provided. Step 3 – Remove the drive foot from the meter drive shaft by unthreading it counterclockwise. The drive foot will not be reused and can be discarded. Then, thread the magnet wheel clockwise onto the shaft. Tighten the magnet wheel until snug to the end of the threads on the drive shaft. CAUTION! Be careful not to cross-thread the magnet wheel when installing it on the meter drive shaft. Cross-threading can cause misalignment of the magnet wheel which in turn can cause binding or erratic performance. Page 88 Note: The washers provided are a precision thickness designed to properly position the index. Use no substitutes. The washers are to be placed between the back of the index and the mounting posts. The screws provided with the MTU replace the original index mounting screws. Insure that the drive foot on the index will be driven by the pin on the magnet wheel as it rotates, then hand tighten the index mounting screws. Gently move the 2-foot hand to check for some free play to insure that the register is not binding up. Step 6 – Next, create an exit notch for the sensor wire by using a nibbler or plastic cutting plier to add a notch approximately 5/32” in diameter to the bottom left edge of the clear index cover. Do not interfere with the drain hole already molded into MTU Instruction for Lancaster Model 175 Gas Meters the clear index cover. Clean up the edges of the notch using a round tapered file. Then position clear index cover on meter head and route sensor cable though notch. Step 7 – Secure MTU bracket assembly and the clear index cover to the meter using the screws that originally held the clear index cover. Tighten index cover screws. Step 8 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Step 9 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 89 MTU Instruction for Lancaster Model 175 Gas Meters Intentionally Left Blank Page 90 MTU Instruction for Mini-Max Electronic Gas Volume Corrector Purpose & Scope This instruction provides a procedure for use in wiring and mounting a STAR MTU to a Mercury Mini-Max Electronic Gas Volume Corrector that has been programmed to be compatible with the STAR MTU. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item Gas Bracket Direct Mount MTU for use with the Mini-Max. Tools Required • 5/32” narrow-blade, slotted (flat-blade) screwdriver • Phillips screwdriver • 8” adjustable wrench. • Wire cutter/stripper 471-2020 - 2/28/2006 Part Number 501-8150R or 5018150RR Quantity Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Page 91 MTU Instruction for Mini-Max Electronic Gas Volume Corrector Installation Procedure Step 1 – Attach the MTU Bracket Assembly onto the top of the Mini-Max gasket and to the gas meter by removing the appropriate hardware from the gas meter and then reinstalling the hardware. connector cap back onto the stain relief and hand tighten. Step 4 – Remove the terminal block TB1 from the circuit board. This will unplug by pulling it straight out. The top terminal (Terminal 1) is common. Step 2 – If both the corrected and uncorrected readings from the Mini-Max will be monitored, there will be two wires coming out of the back of the 5018150RR MTU thru a notch in the bracket. One wire is black and connects to port 1 of the MTU. This will be used for the Corrected Reading. The gray wire connects to port 2 of the MTU and will be used for the Uncorrected reading. If only the corrected reading will be monitored, the 501-8150R MTU will have only a single black wire which is used for the corrected reading. Step 3 – Remove the smaller strain relief connector nut completely and place it over the wire(s). Push the wire(s) into the connector leaving approximately 4 to 5 inches of wire inside the unit. Place the Page 92 Terminal Signal Common Corrected Pulse Output Uncorrected Pulse Output Alarm (-) Alarm (+) Step 5 – Strip ¼ inch of insulation off of each MTU wire. Insert the black and white wires into Terminal 1 (Common). Tighten the screw on the side. Make sure the wires are captured securely. Insert MTU Instruction for Mini-Max Electronic Gas Volume Corrector the red wire from the black cable into Terminal 2. Tighten the screw on the side. Insert the red wire from the gray cable (if used) into Terminal 3. Tighten the screw on the side. Step 6 – Press the terminal block back onto the connector on the circuit board. Make sure that it seats fully. This completes the wiring of the MTU. • Item No. 090 and 092 need to be programmed to match the scaling in the MTU. Ex. Code 1 = CU FT x 10; Code 2 = CU FT x 100. Other settings may be needed for the Mini-max to operate correctly. See the Mini-Max Operators Guide for further instructions. Mini-Max Configuration Notes The Mini-Max must be properly programmed to have the corrected and uncorrected outputs available on TB1. Per the Mini-Max Operator’s Guide: • • • • Item No. 093 should be set to Code 0. This will select the Corrected output to be on for TB1 slot 2. Item No. 094 needs to be programmed to Code 2 in order to select the Uncorrected output to be on TB1 slot 3. Item 096 and 097 should be set to Code 2, which will set the display to 6 digits and match the reading length stored in the MTU. Item No. 115 should be left at the default of 0 which will give a pulse width of 0.0625 Sec. Page 93 MTU Instruction for Mini-Max Electronic Gas Volume Corrector Intentionally Left Blank Page 94 MTU Instruction for Sprague Model 175 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR indirect-mount MTU on a Sprague Model 175 (flat-face) Gas Meter. Parts Required Item MTU, Indirect Mount, for Sprague 175 10-24 x 3/8” Slotted, Fillister Head Machine Screw Wheel/Magnet Assembly MTU spacer for pipe or bar mount 18″ heavy-duty UV-resistant tie wrap 10-32 x 1½″ pan head machine screw 10-32 nut, stainless steel #10 7/16” flat washer, stainless steel 471-2021 - 2/28/2006 Part Number 501-6327H, 501-6327HH or 501-6327HD5 069-102412HA 109-7126A 056-5155K 067-0030 Quantity 069-103248CS 069-3011 069-3004 Page 95 MTU Instruction for Sprague Model 175 Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the index aside until later. The screws that held the index to the meter can be discarded. Small, diagonal plastic cutting pliers 7/16″ boxwrench Safety goggles #1 and #2 Phillips screwdrivers #1 and #2 Slotted screwdrivers See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Installing the Sensor Assembly Before installing the Sensor Assembly, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 – Remove the clear index cover from the meter by removing the screw that holds it. The clear index cover and the index cover screw will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. Page 96 Step 3 – Remove the drive foot from the meter drive shaft by unthreading it counterclockwise. The drive foot will not be reused and can be discarded. Then, thread the magnet wheel clockwise onto the shaft. Tighten the magnet wheel until snug to the end of the threads on the drive shaft. MTU Instruction for Sprague Model 175 Gas Meters CAUTION! Be careful not to cross-thread the magnet wheel when installing it on the meter drive shaft. Cross-threading can cause misalignment of the magnet wheel which in turn can cause binding or erratic performance. Step 4 – Start the two 10-24 x 3/8” machine screws into the index mounting holes. Thread each screw in approximately one full turn. Step 5 – Attach the sensor to the meter by positioning the keyhole-shaped slots of the sensor bracket over the index mounting screws as shown here. Route the sensor wire through the slot at the bottom right-hand corner of the sensor bracket and back to the left under the magnet wheel so that it does not interfere with the magnet wheel or the index gears. Step 6 – Replace the index by hooking the two tabs on the index behind the heads of the index mounting screws. Insure that the drive foot on the index will be driven by the pin on the magnet wheel as it rotates. Several styles of indexes and index drive mechanisms may be encountered. Use the photos below as a guide. Note that on indexes with a slotted drive foot, it is intended that the pin on the magnet wheel engages the slot on the drive foot. Brass Index with Slotted Drive Foot Brass Index with Offset Drive Foot Page 97 MTU Instruction for Sprague Model 175 Gas Meters Plastic Index with Metal Drive Foot Step 7 – Route the sensor wire so that it does not interfere with the magnet wheel or the index gears. Hand tighten index mounting screws. Gently move the 2-foot hand to check for some free play to insure that the register is not binding up. Step 8 – Next, create an exit notch for the sensor wire by cutting away a small piece of the corner where the left hand edge of the clear index cover meets the ridge at the bottom of the meter head. Step 9 – Secure the clear index cover to the meter using the screw that originally held it. Tighten the index cover screw. Step 10 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Bar Mounting the MTU Step 1 - Thread the tie-wraps into the MTU spacer as shown here. Step 2 - Attach the spacer to the MTU using the provided screws and washers. Tighten the screws to 12 to 15 in-lb. On a Page 98 MTU Instruction for Sprague Model 175 Gas Meters standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Step 3 - Wrap the tie wraps around the bar as needed, pulling the ties around (through the spacer plate) as they are tightened. Step 4 - Adjust the MTU as needed and pull the tie wraps tight. Step 5 - Trim off the excess tie wrap, leaving about a ½” tab. Step 6 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 99 MTU Instruction for Sprague Model 175 Gas Meters Intentionally Left Blank Page 100 MTU Instruction for Metron-Farnier Water Meters Purpose & Scope This instruction provides wiring information for connecting a STAR MTU to a MetronFarnier Water Meter equipped with an OER register. Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections. Metron OER Register MTU Cable OER Cable Red R (Red) Black B (Black) White G (Green) Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Application Notes • The 5-digit Metron OER register must be configured for an additional trailing zero for proper operation with STAR MTUs. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. 471-2022 - 2/28/2006 a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. b. Water Meter with Integral Cable If the water meter is supplied with an integral cable and a cable-tocable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 101 MTU Instruction for Metron-Farnier Water Meters Intentionally Left Blank Page 102 MTU Instruction for Nicor Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR MTU to a Nicor Type A, Type C or Type X composite pit lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter inside of the pit. Please refer to Publication 4712000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item Part Number As required for installed meter MTU #8 x 1-1/4” Truss Head Phillips Sheet Metal Screw, 18-8 stainless steel (McMaster # 93406A201) 056-8150S #8 x 2” Phillips Pan Head Sheet Metal Screw, 18-8 stainless steel (McMaster #92470A205) To mount the MTU to these pit lids, you will need the following tools and equipment: • • • Safety goggles #3 Phillips driver bit Cordless Drill 3/8”, variable speed, with adjustable torque settings. 471-2023 - 4/3/2006 2 per Original Style MTU installation Spacers (for pit lid mounting of New Style Flatpak MTUs) Tools Required Quantity 2 per New Style MTU installation 2 per New Style MTU installation Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Page 103 MTU Instruction for Nicor Composite Pit Lids Installation Procedure NOTE: The Nicor Type A, Type C and Type X lids differ only slightly in their rim and latching mechanism. STAR MTUs can be mounted to either a Type A, Type C or a Type X lid using this procedure. Step 3 – Position the MTU face-down on the bottom surface of the pit lid. Place 2 stainless sheet metal screws through the 2 recessed mounting holes as shown, and guide the screws into the holes on the designated mounting posts. Mounting an Original Flatpak STAR MTU to a Nicor pit lid. Step 1 – Place the pit lid top down on a solid surface, positioning the metal latch mechanism nearest to you as shown in the photo below. Step 2 – Note the mounting posts on the bottom of the pit lid. Several posts are provided for mounting a variety of equipment. The posts used for mounting an Original Flatpak STAR MTU are highlighted in the photo below. Step 4 - Torque screws to approximately 8 in-lbs. MTU should be snug and flush to the surface of the pit lid. Step 5 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 6 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Page 104 MTU Instruction for Nicor Composite Pit Lids Mounting a New Flatpak STAR MTU to a Nicor pit lid. Step 1 – Place the pit lid top down on a solid surface, positioning the metal latch mechanism nearest to you as shown in the photo below. Step 2 – Note the mounting posts on the bottom of the pit lid. Several posts are provided for mounting a variety of equipment. The posts used for mounting a New Flatpak STAR MTU are highlighted in the photo below. Step 4 - Place 2 stainless sheet metal screws through the 2 mounting holes and the spacers, and guide the screws into the holes on the designated mounting posts. Step 5 – Torque screws to approximately 8 in-lbs. MTU should be snug and flush to the surface of the pit lid. Step 6 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 7 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. Step 3 – Position the MTU face-down on the bottom surface of the pit lid. Place plastic spacers under the mounting lugs on the MTU as shown below. Page 105 MTU Instruction for Nicor Composite Pit Lids Intentionally Left Blank Page 106 MTU Instruction for American Model AL800-AL5000 Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on an American Model AL800-AL5000 Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item #18-18 x 2.6” slotted round head bolt, stainless #12-24 x 2-¼” slotted fillister head screw, stainless American index cover gasket Security cups Security caps 2-pin drive disk Tall, 2-slot coupler with magnet Shaft, standard Adapter, 5155 style MTU enclosure to pulser body ¼-20 x 1-½” Phillips pan head machine screw, stainless ¼-20 nylock nut, stainless #8-18 x ½” Phillips pan head thread forming screw, stainless MTU/Pulser Assembly (or separate MTU and pulser) 471-2026 - 7/18/2007 Part Number 069-181880DS 069-122472HS 066-0033 066-0336 066-0337 056-11585C 056-11585B 056-5155D 056-11585D 069-142048AS 069-3222 069-080016A4S per project Quantity Page 107 MTU Instruction for American Model AL800-AL5000 Gas Meters Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 18-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 2- Loosen and remove the four screws securing the index base plate assembly to the meter. You may discard these screws as they will not be re-used. Remove the index box and base plate assembly from the top of the meter. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Once this is complete, you can mount the MTU remotely or directly on the pulser using the adapter provided. If you are mounting the MTU on the pulser, it can be mounted at either the front or back of the meter. Step 1 – If necessary, remove tamper seals from any of the 4 screws that secure the index base plate and the two screws that secure the index box to the base plate. Note: If the index base plate has integral security towers like the one on the left below, it must be replaced with the flat style index base plate like the one shown on the right. Page 108 Step 3 – Disassemble the index box from the base plate by removing the two screws that secure the index box to the base plate. You may discard these screws as they will not be re-used. Step 4 – If the index box and/or base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the new hardware that will retain the index base plate, the pulser and the index box. Use the blind-hole taps to carefully clean the threads of the index box and base plate mounting holes. CAUTION! The index base plate mounting holes use a #18-18 thread. The index box mounting holes use a #12-24 thread. Be sure to use the proper tap for each hole. Using the wrong tap will result in damage to the meter head. MTU Instruction for American Model AL800-AL5000 Gas Meters After using the tap, blow out the holes with compressed (canned) air. Step 5 – Place the index base plate onto the head of the meter. Align the index base plate with the index plate mounting holes on the meter head and the large opening in the base plate is centered over the drive mechanism. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.) Step 7 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Tall Coupler, and that the retaining shaft is securely snapped into both the Tall Coupler and the 2-Pin Drive Disk. Step 8 – Place the pulser on the index base plate, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Page 109 MTU Instruction for American Model AL800-AL5000 Gas Meters Step 9 – Fasten the pulser to the meter body using the four #18-18 x 2.6” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below. Step 10 – If the index box assembly has a silicone gasket applied around its bottom edge and that gasket is in good shape, you can discard the index cover gasket supplied with the pulser and skip to Step 11. Otherwise, place the index cover gasket on the pulser, aligning the gasket as shown below. Step 11 – Place the index box assembly on the pulser, aligning the the drive foot with the two-pin drive disk. Fasten the index box to the meter with the two #1224 x 2-¼” slotted, stainless steel fillister head screws provided. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Continue to Step 12 if you will be mounting the MTU to the pulser body. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies. If provided as separate components, connect the three wires in the pulser cable (red, black, and white) to the corresponding wires in the MTU cable. NOTE: When using the cork gasket supplied with the pulser, be sure that the bottom edge of the index box is clean and free of any silicone and/or dirt particles. Page 110 MTU Instruction for American Model AL800-AL5000 Gas Meters Step 12 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided, as shown below. Step 13 – Bundle the excess wire into the compartment on the adaptor. Step 14 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Page 111 MTU Instruction for American Model AL800-AL5000 Gas Meters Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 112 MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on a Rockwell/Equimeter Model 750-10000 Intermediate or Large Capacity Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item 5/16 -18 x 2 1/4” slotted fillister head bolt, stainless 5/16 -18 x 3” slotted fillister head bolt, stainless Gasket, large pulser, upper, Rockwell Index Cover Gasket, large pulser, lower, standard Standard coupler – with magnet Tall, 2-slot coupler Shaft, standard Adapter, 5155 style MTU enclosure to pulser body ¼-20 x 1-½” Phillips pan head machine screw, stainless ¼-20 nylock nut, stainless #8-18 x ½” Phillips pan head thread forming screw, stainless MTU/Pulser Assembly (or separate MTU and pulser) 471-2027 - 7/18/2007 Part Number 069-561872HS 069-561896HS 066-11585B 066-11585A 056-11703B 056-11585B 056-5155D 056-11585D 069-142048AS 069-3222 069-080016A4S per project Quantity Page 113 MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Tools Required • • • • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) 7/16” box wrench 5/16-18 blind-hole (bottoming) tap and mating size T-handle Canned compressed air Step 2 – Loosen and remove the screws securing the index to the index plate. You may discard these screws as they will not be re-used. Next, remove the index and set it aside. Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Once this is complete, you can mount the MTU remotely or directly on the pulser using the adapter provided. If you are mounting the MTU on the pulser, it can be mounted at either the front or back of the meter. Step 1 – If necessary, remove tamper seals that cover the index cover screws. Loosen and remove the screws securing the index cover. You may discard these screws as they will not be re-used. Remove the index cover and set it aside. Page 114 Step 3 – If the index cover screws and index mounting screws were difficult to remove, the threads in the index plate may need to be cleaned out before installing the pulser assembly. Use the blind-hole tap to carefully clean the threads of the four 5/16” holes. Blow out the holes with compressed (canned) air. CAUTION! The index base plate mounting holes use a 5/16-18 thread. Be sure to use the proper tap. Using a tap other than a 5/16-18 tap will result in damage to the meter head. MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 4 – Position the lower gasket on the meter as shown in the illustration below. Step 6 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Standard Coupler, and that the retaining shaft is securely snapped into both couplers. Step 5 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.) Page 115 MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 7 – Place the pulser on the meter, aligning the lower coupler so that it will engage the fork portion of the meter drive foot as shown below. Step 8 – Next, place the upper gasket on top of the pulser as shown in the illustration below. Ensure that the pulser body sits properly on the gasket and that the wire is routed through the wire exit notch. Step 9 – Mount the index onto the pulser using the 5/16 -18 x 2 1/4” slotted fillister head bolts provided, as shown in the illustration below. Ensure that the drive foot on the index engages with the slot in the top of the tall coupler. Page 116 MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 10 – Next, mount the index cover onto the pulser using the 5/16 -18 x 3” slotted fillister head bolts provided, as shown in the illustration below. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Continue to Step 11 if you will be mounting the MTU to the pulser body. Step 11 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided, as shown below. Step 12 – Bundle the excess wire into the compartment on the adaptor. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies. If provided as separate components, connect the three wires in the pulser cable (red, black, and white) to the corresponding wires in the MTU cable. Page 117 MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 13 – Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 14 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 118 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on an Sprague/Actaris Model 675A, 800A or 1000A Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item ¼-20 x 2-1/4” slotted fillister head bolt, stainless Sprague index cover gasket Gasket, large pulser, lower, standard Standard coupler - with magnet Tall, 2-slot coupler Shaft, standard Adapter, 5155 style MTU enclosure to pulser body ¼-20 x 1-½” Phillips pan head machine screw, stainless ¼-20 nylock nut, stainless #8-18 x ½” Phillips pan head thread forming screw, stainless MTU/Pulser Assembly (or separate MTU and pulser) Shaft, extended ½” OD x ¼” L round nylon spacer 471-2028P - 7/18/2007 Part Number 069-142072HS 066-0034 066-11585A 056-11703B 056-11585B 056-5155D 056-11585D 069-142048AS 069-3222 069-080016A4S per project 056-12466B 068-141608EX Quantity Page 119 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 1/4-20 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 3 – Remove the two screws securing the index to the top of the meter. You may discard these screws as they will not be re-used. Remove the index and set it aside. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Once this is complete, you can mount the MTU remotely or directly on the pulser using the adapter provided. If you are mounting the MTU on the pulser, it can be mounted at either the front or back of the meter. Step 1 – If necessary, remove tamper seals from any of the four screws that secure the index cover to the meter body. Step 2- Loosen and remove the four screws securing the index cover to the meter. You may discard these screws as they will not be re-used. Remove the index cover from the top of the meter. Step 4 – If the index base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the hardware that will retain the index base plate, the pulser and the index box. Use the blindhole tap to carefully clean the threads of the index base plate mounting holes. CAUTION! The index base plate mounting holes use a 1/4-20 thread. Be sure to use the proper tap. Using a tap other than a ¼-20 tap will result in damage to the meter head. After using the tap, blow out the holes with compressed (canned) air. Page 120 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Step 5 – Place the lower gasket onto the meter, aligning it as shown to insure that the openings for the index bolts and index cover bolts match up with the threaded holes on the top of the meter. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.) Step 8 – Place the pulser on the lower gasket, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Step 9 – Position the index on top of the pulser, aligning the drive pin on the index with the slot on the tall coupler. Ensure that there is no binding. Step 7 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Standard Coupler, and that the retaining shaft is securely snapped into both couplers. Note: On some models, a ‘shorter’ index may not allow sufficient clearance between the tall coupler and the index. In this case, replace the standard shaft with the extended shaft and insert the nylon spacers provided between the index and the pulser body. Page 121 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Fasten the index to the meter with two of the ¼-20 x 2-1/4” slotted, stainless steel fillister head bolts provided. Step 10 – Place the index cover gasket in position on top of the pulser and then place the index cover on the top of the gasket. Fasten the index cover to the meter using the four remaining ¼-20 x 21/4” slotted, stainless steel fillister head bolts. Step 11 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided. Step 12 – Bundle the excess wire into the compartment on the adaptor. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Continue to Step 11 if you will be mounting the MTU to the pulser body. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies. If provided as separate components, connect the three wires in the pulser cable (red, black, and white) to the corresponding wires in the MTU cable. Page 122 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Step 13 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 14 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 123 MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Intentionally Left Blank Page 124 MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on Dresser Roots-Type Gas Meters with Vertical Mechanical Index. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item 5/16-18 x 3” slotted round head bolt, stainless #12-24 x 2-¼” slotted fillister head screw, stainless American index cover gasket Security cups Security caps 2-pin drive disk Tall, 2-slot coupler with magnet Shaft, standard Adapter, 5155 style MTU enclosure to pulser body ¼-20 x 1-½” Phillips pan head machine screw, stainless ¼-20 nylock nut, stainless #8-18 x ½” Phillips pan head thread forming screw, stainless MTU/Pulser Assembly (or separate MTU and pulser) 471-2029 - 7/18/2007 Part Number 069-561896DS 069-122472HS 066-0033 066-0336 066-0337 056-11585C 056-11585B 056-5155D 056-11585D 069-142048AS 069-3222 069-080016A4S per project Quantity Page 125 MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 5/16-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 2- Loosen and remove the four screws securing the index base plate assembly to the instrument drive. You may discard these screws as they will not be re-used. Remove the index box and base plate assembly from the top of the meter. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Once this is complete, you can mount the MTU remotely or directly on the pulser using the adapter provided. If you are mounting the MTU on the pulser, it can be mounted at either the front or back of the register. Step 1 – If necessary, remove tamper seals from any of the 4 screws that secure the index base plate and the two screws that secure the index box to the base plate. Note: If the index base plate has integral security towers like the one on the left below, it must be replaced with the flat style index base plate like the one shown on the right. Page 126 Step 3 – Disassemble the index box from the base plate by removing the two screws that secure the index box to the base plate. You may discard these screws as they will not be re-used. MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 4 – If the index box and/or base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the new hardware that will retain the index base plate, the pulser and the index box. Use the blind-hole taps to carefully clean the threads of the index box and base plate mounting holes. CAUTION! The index base plate mounting holes use a 5/16-18 thread. The index box mounting holes use a #12-24 thread. Be sure to use the proper tap for each hole. Using the wrong tap will result in damage to the meter head. After using the tap, blow out the holes with compressed (canned) air. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.) Step 7 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Tall Coupler, and that the retaining shaft is securely snapped into both the Tall Coupler and the 2-Pin Drive Disk. Step 5 – Place the index base plate onto the instrument drive of the meter. Align the index base plate with the index plate mounting holes on the instrument drive so that the large opening in the base plate is centered over the drive mechanism. Page 127 MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 8 – Place the pulser on the index base plate, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Step 9 – Fasten the pulser to the instrument drive using the four 5/16-18 x 3” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below. Step 10 – If the index box assembly has a silicone gasket applied around its bottom edge and that gasket is in good shape, you can discard the index cover gasket supplied with the pulser and skip to Step 11. Otherwise, place the index cover gasket on the pulser, aligning the gasket as shown below. NOTE: When using the cork gasket supplied with the pulser, be sure that the bottom edge of the index box is clean and free of any silicone and/or dirt particles. Page 128 MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 11 – Place the index box assembly on the pulser, aligning the the drive foot with the two-pin drive disk. Fasten the index box to the meter with the two #1224 x 2-¼” slotted, stainless steel fillister head screws provided. Step 12 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided. Step 13 – Bundle the excess wire into the compartment on the adaptor. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Continue to Step 12 if you will be mounting the MTU to the pulser body. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies. If provided as separate components, connect the three wires in the pulser cable (red, black, and white) to the corresponding wires in the MTU cable. Page 129 MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 14 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 130 MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on Romet Roots-Type Gas Meters with Vertical Mechanical Index. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item 5/16-18 x 3” slotted round head bolt, stainless #12-24 x 2-¼” slotted fillister head screw, stainless American index cover gasket Security cups Security caps 2-pin drive disk Tall, 2-slot coupler with magnet Shaft, standard Adapter, 5155 style MTU enclosure to pulser body ¼-20 x 1-½” Phillips pan head machine screw, stainless ¼-20 nylock nut, stainless #8-18 x ½” Phillips pan head thread forming screw, stainless MTU/Pulser Assembly (or separate MTU and pulser) 471-2030 - 7/18/2007 Part Number 069-561896DS 069-122472HS 066-0033 066-0336 066-0337 056-11585C 056-11585B 056-5155D 056-11585D 069-142048AS 069-3222 069-080016A4S per project Quantity Page 131 MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 5/16-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 2- Loosen and remove the four screws securing the index base plate assembly to the instrument drive. You may discard these screws as they will not be re-used. Remove the index box and base plate assembly from the top of the meter. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Once this is complete, you can mount the MTU remotely or directly on the pulser using the adapter provided. If you are mounting the MTU on the pulser, it can be mounted at either the front or back of the meter. Step 1 – If necessary, remove tamper seals from any of the 4 screws that secure the index base plate and the two screws that secure the index box to the base plate. Note: If the index base plate has integral security towers like the one on the left below, it must be replaced with the flat style index base plate like the one shown on the right. Page 132 Step 3 – Disassemble the index box from the base plate by removing the two screws that secure the index box to the base plate. You may discard these screws as they will not be re-used. MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 4 – If the index box and/or base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the new hardware that will retain the index base plate, the pulser and the index box. Use the blind-hole taps to carefully clean the threads of the index box and base plate mounting holes. CAUTION! The index base plate mounting holes use a 5/16-18 thread. The index box mounting holes use a #12-24 thread. Be sure to use the proper tap for each hole. Using the wrong tap will result in damage to the meter head. After using the tap, blow out the holes with compressed (canned) air. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.) Step 7 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Tall Coupler, and that the retaining shaft is securely snapped into both the Tall Coupler and the 2-Pin Drive Disk. Step 5 – Place the index base plate onto the instrument drive of the meter. Align the index base plate with the index plate mounting holes on the meter head so that the large opening in the base plate is centered over the drive mechanism. Page 133 MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 8 – Place the pulser on the index base plate, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Step 9 – Fasten the pulser to the instrument drive using the four 5/16-18 x 3” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below. Step 10 – If the index box assembly has a silicone gasket applied around its bottom edge and that gasket is in good shape, you can discard the index cover gasket supplied with the pulser and skip to Step 11. Otherwise, place the index cover gasket on the pulser, aligning the gasket as shown below. NOTE: When using the cork gasket supplied with the pulser, be sure that the bottom edge of the index box is clean and free of any silicone and/or dirt particles. Page 134 MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 11 – Place the index box assembly on the pulser, aligning the the drive foot with the two-pin drive disk. Fasten the index box to the meter with the two #1224 x 2-¼” slotted, stainless steel fillister head screws provided. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies. If provided as separate components, connect the three wires in the pulser cable (red, black, and white) to the corresponding wires in the MTU cable. Step 12 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided. Step 13 – Bundle the excess wire into the compartment on the adaptor. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Continue to Step 12 if you will be mounting the MTU to the pulser body. Page 135 MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 14 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 136 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Actaris/Sprague/Schlumberger residential gas meters: 175, 250 and 400 (Slantface). Parts Required Ref. # 2a 2b 2c Item Gasket MTU, Sprague Direct Mount Magnet Coupler Coupler Shaft Register Coupler #10 x 3/8” combo head thread form screw, Type A, zinc 10-24 x 2” slotted fillister head machine screw, zinc 471-2031 - 7/18/2007 Part Number 066-11583 per project 056-11703B 056-5155D 056-11583D 069-100012C3A 069-102464HA Quantity Page 137 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • #2 Phillips screwdriver • ¼” Slotted screwdriver • 2 alignment studs – Hexagram part number xxx-yyyy Step 4 – Next, turn the MTU over and mount the register onto the MTU (see illustration below) fastening the register to the MTU with the #10 x 3/8” screws provided. Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the three screws that hold it. Set the cover aside and discard the screws. Step 2 - Remove the register by removing the two screws that hold it. Set the register aside and discard the screws. Step 3– Remove the paper backing from the gasket provided to expose the pressure sensitive adhesive. Place the gasket on the back of the MTU with the adhesive surface facing the MTU so that it aligns over the three mounting screws and the raised gasket surface of the MTU. Start the two screws into the mounting holes, and then slide the register beneath the screws, making sure that the wiggler on the register is aligned with the MTU coupler. Tighten both screws to a torque not to exceed 3-5 inch-pounds. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Use of power tools is not recommended. Page 138 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 5 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 6 – Next, thread alignment studs into the threaded mounting holes on the left and right side of the index box, as shown below. Step 8 – Now, slide the clear register cover over the alignment studs while you hold the MTU in position with your free hand. Step 9 - Next, insert one of the #10-24 x 2” screws through the top-center hole on the clear register cover. Tighten this screw just sufficiently to hold the MTU and register cover to the meter. Step 7 – Next, slide the MTU over the alignment studs, positioning the coupler on the MTU to ensure that it engages correctly with the wiggler on the gas meter. Page 139 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 10 – Next, remove one of the alignment studs and replace it with another one of the #10-24 x 2” screws provided. Continue in a similar manner, replacing the other alignment stud with a #10-24 x 2” screw. Tighten all three screws to a torque not to exceed 12 -15 inch-pounds. The gasket should be compressed slightly. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure. Because of this, power tools are not recommended for this procedure. Page 140 Step 11 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 12 – Once Installation is complete, program the MTU using your field programmer and the STAR Programmer Software. MTU Instruction for Armorcast Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR MTU to an Armorcast Composite Pit Lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item MTU Part Number As required for installed meter Hillman #370342 (10-12x1”) Anchors Quantity 2 per installation #8 x 2” Galvanized Sheet Metal Screws 2 per Original Style MTU installation Long Spacers (for pit lid mounting of New Style Flatpak MTUs) 056-8150L #8 x 2 1/2” Galvanized Sheet Metal Screws 2 per New Style MTU installation 2 per New Style MTU installation Tools Required • Hammer To mount the MTU to these pit lids, you will need the following tools and equipment: • #2 Phillips Screwdriver • Cordless Drill 3/8”, variable speed, with adjustable torque settings. • • Safety goggles #2 Phillips driver bit 471-2032 - 9/22/2006 Page 141 MTU Instruction for Armorcast Composite Pit Lids Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Step 3 – Use a hammer to gently tap anchors into the holes indicated in the previous photo. Step 4 – Position the MTU face-up on the bottom surface of the pit lid. Place 2 #8 x 2” galvanized sheet metal screws through the mounting holes as shown below, and guide the screws into the anchors. Installation Procedure Mounting an Original Flatpak STAR MTU to an Armorcast pit lid. Step 1 – Place the pit lid top down on a solid surface. Step 2 – Note the pre drilled mounting holes on the bottom of the pit lid. The holes used for mounting an Original Flatpak STAR MTU are highlighted in the photo below. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Do not tighten screws beyond the point that the MTU touches the mounting surface. Power tools are not recommended for use when mounting an Original Flatpak STAR MTU to Armorcast lids. Step 5 – Hand tighten the screws to approximately 8 in-lbs. MTU should be snug to the surface of the pit lid. Step 6 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Page 142 MTU Instruction for Armorcast Composite Pit Lids Step 7 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 3 – Use a hammer to gently tap anchors into the holes indicated in the previous photo. Step 4 – Position the MTU face-down on the bottom surface of the pit lid as shown below. Insure that cable exit from the MTU faces the rim of the lid. Step 5 - Place plastic spacers under the mounting lugs on the MTU as shown below. Position the spacers so that the notched ends mate up with the mounting tabs on the MTU. Note that the spacers should provide a gap of approximately 3/8” between the bottom surface of the lid and the top surface of the MTU. Mounting a New Flatpak STAR MTU to an Armorcast pit lid. Step 1 – Place the pit lid top down on a solid surface. Step 2 – Note the pre drilled mounting holes on the bottom of the pit lid. The holes used for mounting an New Flatpak STAR MTU are highlighted in the photo below. Step 6 - Place 2 #8 x 2 ½” galvanized sheet metal screws through the mounting holes and the spacers, and guide the screws into the anchors. Step 7 – Torque screws to approximately 8 in-lbs. MTU should be snug to the surface of the pit lid. Step 8 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 9 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. Page 143 MTU Instruction for Armorcast Composite Pit Lids Intentionally Left Blank Page 144 MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Pulser on a Sprague/Actaris ‘Curb-type’ Gas Meter with top mounted index. Parts Required Ref Item #10-32 x 2” slotted fillister head machine screw, brass Register (Index) Cover Cover Gasket, notched #6-19 x ½” Phillips pan head, hi-low thread forming screw, stainless Single-pin Index Drive, with Magnet Shaft, standard MTU/Pulser Assembly Coupler Neoprene rubber gasket Part Number Qty 069103264HC 056-0561 066-0037 069060016A4S 056-11583D 056-5155D 506-11703 056-11703B 066-0035 Tools Required • • • Wire Brush Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • Two (2) Alignment Studs Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure There are two parts to this procedure. First, the pulser must be mounted to the meter. Then, the MTU must be mounted in a nearby location that will allow RF transmissions to propagate. 471-2033 - 4/28/2008 Page 145 MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 1 – If necessary, remove tamper seals from any of the four screws that secure the index cover to the meter body. Step 2- Loosen and remove the four screws securing the index cover to the meter. You may discard these screws as they will not be re-used. Remove the index cover and the index cover gasket from the top of the meter and discard. You will replace both the cover and the gasket during reassembly. Step 3 – Remove the two screws securing the index to the top of the meter. You may discard these screws as they will not be re-used. Remove the index register and set it aside. Page 146 Step 4 – Verify that the couplers and shaft are attached to the pulser body as shown below. Ensure that these components are securely snapped together and that the magnet is in place on the Single-pin Index Drive. Step 5 – Mount the index to the pulser using the #6-19 Phillips screws provided. You can start the screws in the posts on the pulser body first. Then engage the tabs on the index with the mounting screws. Ensure that the pin on the index drive engages the wiggler on the index. MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Step 6 – Place the gasket provided onto the meter, aligning it as shown to insure that the openings for the index cover bolts match up with the threaded holes on the top of the meter. Use the two (2) alignment studs to aid in alignment and assembly of parts. NOTE: PG&E Code 23-2097 for cover gasket and Code 23-4931 for plastic cover. Step 7 – Position the pulser and index on the meter, aligning the four holes with the threaded holes on top of the meter. Ensure that the coupler on the pulser engages the drive dog on the meter. You can orient the index in any direction. Step 8 – Place the supplied index cover and notched index cover gasket on the pulser, again aligning the notches in the gasket with the index mounting posts. Then fasten the assembly to the meter using the four #10-32 x 2” brass machine screws provided. Alternately tighten opposite screws to evenly compress the gaskets. NOTE: Use “red” security caps and “putty” to seal screw wells. Page 147 MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Step 9 – Mount the MTU. Please refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 10 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 148 MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on American Meter Company 5B-225 meters. Parts Required Ref. # 10 11 Item Cork Gasket Adaptor Plate Rubber Gasket MTU, Direct Mount Coupler, MTU Extended Shaft Coupler, MTU with Magnet (Magnet 036-0002) #8 x 3/8” Combo Head Sheet Metal Screw, Zinc ¼-20 x 1 5/8” Slotted Fillister Head Machine Screw Register Cover #10 x 1” Combo Head Sheet Metal Screw, Zinc 471-2034 - 7/18/2007 Part Number 066-12466B 056-12466A 066-12466A per project 056-5155E2 056-12466B 056-5155E2 069-080012C4A 069-142040GA 109-7712A 069-100032C3A Quantity Page 149 MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • Phillips screwdriver • Slotted screwdriver Step 4 - Mount the register onto the MTU, fastening the register to the mounting holes shown here with the #8 x 3/8” screws provided. Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws that hold it. Discard both the screws and the cover. Step 2 - Remove the register by removing the two screws that hold it. Set the register aside. Discard the screws. Step 3 – Assemble the couplers and extended shaft to the MTU. Ensure that the coupler with the magnet is on the front (register side) of the MTU and that the extended shaft protrudes from the back of the MTU with the other coupler. The notch of the front side coupler (with magnet) should be at the 12 o’clock position when the notch on the backside coupler faces 3 o’clock (90°). Page 150 Start one of the two screws into the mounting hole, and then slide the register beneath the screw aligning the wiggler on the register with the MTU coupler. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Use of Power tools is not recommended. Then insert the second screw and tighten both screws to a torque not to exceed 3-5 inch-pounds. Note: On some odometer-style registers like the one shown below, slight protrusions on the back of the register assembly can interfere with proper alignment of the register. Should this occur, use a diagonal cutting plier to trim the two wire guides on the MTU to the right of the coupler. Trim these guides as close to flush with the MTU enclosure as possible. (See MTU photo below.) MTU Instruction for American Meter Company Gas Meters Step 7– Turn the MTU over and place the rubber gasket on the back of the MTU so that it aligns over the two screws. Step 8 – Next, place the adaptor plate on the back of the MTU so that it aligns over the two screws. Step 5 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 6 – Next, Insert the two ¼-20 x 1 5/8” machine screws through the holes on the MTU as shown here. Step 9 – The cork gasket is normally preapplied to the adaptor plate. Ensure that it is in position on the back of the adaptor plate. Step 10 – Next, position the MTU on the meter. Tighten the two ¼-20 x 1 5/8” mounting screws most of the way, and then rotate the register dials slightly to engage the wiggler on the gas meter. The wiggler must engage with the rear coupler on the MTU as shown in these illustrations. (Coupler shown detached from the MTU for illustration purposes only.) Half-foot Drive Quarter-foot Drive Page 151 MTU Instruction for American Meter Company Gas Meters Step 11 – Now, firmly hand tighten the two screws to 12 to 15 in-lb. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure. Because of this, power tools are not recommended for this procedure. Step 12 - Check the coupling one more time. It should have slight play — it should not bind or turn too freely. Step 13 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and Page 152 insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Step 14 – Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 15 – Once Installation is complete, program the MTU using your Field Programmer and the STAR Programmer Software. MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the Rockwell/Equimeter/Sensus R415 Meters. Parts Required Ref. # Item Gasket, Adaptor Plate to Meter Part Number 066-0032 Adapter Plate, R415 10-24 x 3/4” Slotted, Fillister Head Machine Screw, Zinc Coupler, Female, 18 Tooth Gear (orange) 056-12331C 069-102424HA 056-12331B Coupler Shaft, MTU 056-5155D Gasket, Adaptor Plate to MTU 066-12331A 10 11 12 13 14 MTU, Direct Mount 18 Tooth Gear, Male, R415 (orange) Magnet ¼-20 x 1 1/4” Slotted, Fillister Head Machine Screw, Zinc #6 Round Spacer, Nylon #6 x 1 1/4” Combo Panhead Sheet Metal Screw, Zinc Register Cover, MTU #10 x 1” Combo Head Sheet Metal Screw, Zinc 506-7712RO 056-12331A 036-0002 069-142040HA 068-0051 069-060040C3A 109-7712A 069-100032C3A 471-2035 - 1/14/2008 Quantity Page 153 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Putty knife Step 3 - Remove the existing gasket and use the putty knife to clean any remnants of the old gasket from the mating surfaces. Step 4 – Insure that the new cork gasket is properly applied to the meter (ribbed) side of the adaptor plate and fasten the adaptor plate and gasket to the meter using the four 10-24 x ¾” machine screws provided. Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws. Discard the screws and cover. Step 2 - Remove the register by removing the two screws. Set the register aside. Discard the screws. Page 154 Step 5 – Remove and discard the existing couplers and shaft from the MTU and assemble the new couplers and shaft to the MTU, positioning the female coupler at the back of the MTU and the 18-tooth gear with magnet at the front as shown below. Ensure that both couplers are securely snapped on to the coupler shaft. MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 6– Insert the two ¼-20 x 1-1/4” machine screws into the holes on the MTU as shown. Step 8 - Position the MTU on the meter, sliding the female coupler over the drive gear on the meter. Tighten the MTU mounting screws to 12 to 15 in-lb. Step 7 – Turn the MTU over and position the rubber gasket over the screws and female coupler as shown. Check the coupler. It should have slight play — it should not bind or turn too freely. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on steps 8-12. Page 155 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 9 - On the register, insert the two #6 x 1-1/4” sheet metal screws and spacers as shown. Step 11 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Step 12 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 10 - Mount the register to the MTU, fastening it to the mounting holes shown below. Hand tighten to a torque not to exceed 3-5 inch-pounds. Make sure the index register gear and the MTU coupler gear are engaged. Step 13 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 156 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Rockwell/Equimeter/Sensus 175S meters. Parts Required Ref. # Item Gasket, Adaptor Plate to Meter Part Number 066-0032 Adaptor Plate, 175S 10-24 x 1/2” Slotted, Fillister Head Machine Screw, Zinc Coupler, Female, 12 Tooth 175S Coupler Shaft, MTU 056-12330CC 069-102416HA 056-12330B 056-5155D 10 11 12 13 14 Gasket, Adaptor Plate to MTU MTU, Direct Mount 12 Tooth Gear, Male, 175S Magnet 10-24 x 1-1/8” Slotted, Fillister Head Machine Screw, Zinc #6 Round Spacer, Nylon #6 x 1 1/4” Combo Head Sheet Metal Screw, Zinc Register Cover, MTU #10 x 1” Combo Head Sheet Metal Screw, Zinc 066-12330C per project 056-12330A 036-0002 069-102436HA 068-0051 069-060040C3A 109-7712A 069-100032C3A 471-2036 - 1/14/2008 Quantity Page 157 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws. Discard the screws and cover. Step 2 - Remove the register by removing the two screws. Set the register aside. Discard the screws. Page 158 Step 3 – Insure that the cork gasket is properly applied to the meter (ribbed) side of the adaptor plate and fasten the adaptor plate and gasket to the meter using the four 10-24 x 1/2” machine screws provided. MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 4 – Remove and discard the existing couplers and shaft from the MTU and assemble the new couplers and shaft to the MTU, positioning the female coupler at the back of the MTU and the 12-tooth gear with magnet at the front as shown below. Ensure that both couplers are securely snapped on to the coupler shaft. Step 7 - Position the MTU on the meter, sliding the female coupler over the drive gear on the meter. Tighten the MTU mounting screws to 12 to 15 in-lb. Step 5 – Insert the four #10-24 x 1-1/8” machine screws into the holes at the corners of the index box as shown. Check the coupler. It should have slight play — it should not bind or turn too freely. Step 6 – Turn the MTU over and position the rubber gasket over the screws and female coupler as shown. The cork side of the gasket should face out as shown below. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on steps 8-12. Page 159 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 8 - On the register, insert the two #6 x 1-1/4” sheet metal screws and spacers as shown. Step 10 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Step 11 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 9 - Mount the register to the MTU, fastening it to the mounting holes shown below. Hand tighten to a torque not to exceed 3-5 inch-pounds. Make sure the index register gear and the MTU coupler gear are engaged. Step 12 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 160 MTU Instruction for Rockwell 175-EMCO Gas Meters Purpose & Scope Installation Procedure This instruction provides a procedure for use in installing a Hexagram STAR MTU on a Rockwell 175-EMCO Gas Meter. Please also refer to Publication 4712000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 1 – If necessary, remove any antitamper seals or security hardware from the index cover. Step 2- Loosen and remove the two screws securing the index cover to the meter. Set the screws and the index cover aside. These items will be reused during reassembly. Step 3 – Remove the index by removing the two screws securing the index to the meter. Set the screws aside. Parts Required Item Part Number Qty Magnet Clip with Magnet 056-12469A Sensor Clip MTU/Sensor Assembly 056-12469B 506-7712BRO1 Tools Required • • Step 4 – Turn the index over and slide the magnet clip onto the index drive dog as shown. Slide the clip onto the drive dog until it snaps into place. Screwdriver, #2 Phillips Screwdriver, 1/4” slotted (flatblade) • Round file Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. 471-2037 - 4/28/2008 Page 161 MTU Instruction for Rockwell 175-EMCO Gas Meters Step 5 – Snap the sensor clip onto the back of the index as shown. Step 9 – Route the sensor cable to the left of the index and position the MTU and index cover on the meter aligning the sensor cable with the notch in the meter body at the bottom left of the index cover. Fasten the MTU and index cover to the meter using the original screws removed in Step 2. Step 6 – Position the index on the meter and attach the index using the index mounting screws removed in Step 3. Ensure that the meter drive engages the index drive dog as shown below. Step 7 – Snap the sensor of the MTU into the sensor clip as shown. Step 8 – Using a round file, file a 1/8” notch .on the lower left corner of the rim of the index cover. This notch will provide an exit for the sensor wire. Step 10 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer. Page 162 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR remote-mount MTU on the following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315, RT210. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item MTU, Rockwell Remote Mount, with sensor #6 x 3/4” Philips Panhead Sheet Metal Screw #10-24 x 1-1/2” Slotted, Fillister Head Machine Screw Part Number per project 069-06000242A 069-102448HA Quantity Tools Required Installation Procedure To mount the MTU to these meters, you will need the following tools and equipment: Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover. • • • Safety goggles Phillips screwdriver Slotted screwdriver Step 1 - Remove the existing clear register cover by removing the four screws that hold it. Set the cover aside. Discard the screws. Step 2 - Remove the register by removing the two screws. Discard the screws. 471-2038 - 7/18/2007 Page 163 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 3 – Position the register on the front of the sensor assembly, aligning the drive gear with the index drive. Mount the index to the sensor assembly using the two #6 x 3/4” screws provided. Step 4 – Carefully remove the protective cap from the drive coupler on the rear of the sensor assembly. Note the tooth on the inner surface of the coupler. Step 5 - Position the sensor on the meter. so that the tooth on the coupler engages with the teeth on meter’s index drive gear. If engaged correctly, the cork gasket on the sensor will fit flush against the surface of the index box. Page 164 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 6 – Position the clear register cover on the front of the sensor and fasten the assembly to the meter using the four 1024 x 1-1/2” screws provided. Hand tighten these screws to a torque not to exceed 12-15 inch pounds. Step 7 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 8 – Mount the MTU, following the wiring and mounting guidelines outlined in Publication 471-2000, General Installation and Wiring Guidelines. If necessary, the MTU cable can be extended up to 500 feet. Step 9 – Once Installation is complete, program the MTU using your Field Programmer and the STAR Programmer Software. Page 165 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Intentionally Left Blank Page 166 MTU Instruction for Landis & Gyr Focus MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing Landis & Gyr Focus MTU/Electric Meter Assemblies. WARNING! Be sure to follow all applicable electrical codes, standards and safety procedures during all phases of operation, service and repair of this device. Any work on energized meters and meter sockets presents a danger of electrical shock. Meter socket terminals carry the full incoming service voltage. Touching these terminals may result in death or serious injury. The information contained in this document is intended to be an aid to qualified metering personnel. It is not intended to replace the extensive training necessary to handle metering equipment in a safe manner. Supplies and Tools Required Physical Installation of the Landis & Gyr Focus MTU/Electric Meter Assemblies into compatible meter sockets can be accomplished without the use of tools. 471-2040 – 2/13/2007 Testing of the meter socket, however, may require specialized equipment. Check with the local electric utility for required testing procedures. Page 167 MTU Instruction for Landis & Gyr Focus MTU/Electric Meter Assembly Installation Procedure Step 1 – Complete all test procedures required by the local electric utility and verify that the meter socket has been correctly installed and wired. Step 3 – Place the meter/MTU assembly into the meter socket, carefully aligning the contact blades with the corresponding jaws in the meter base. Step 4 – Make a final visual inspection to ensure that the meter/MTU assembly is seated, sealed properly, and receiving power. Step 5 – Installation is now complete, program the MTU using the STAR Programmer Software and your Field Programmer. When programming the integral MTU mounted in this meter, hold the programming coil at the 9 o’clock position as shown here. Step 2 – If applicable, remove the existing meter assembly from the meter socket. Page 168 MTU Instruction for Landis & Gyr S4 MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing Landis & Gyr S4 MTU/Electric Meter Assemblies. WARNING! Be sure to follow all applicable electrical codes, standards and safety procedures during all phases of operation, service and repair of this device. Any work on energized meters and meter sockets presents a danger of electrical shock. Meter socket terminals carry the full incoming service voltage. Touching these terminals may result in death or serious injury. The information contained in this document is intended to be an aid to qualified metering personnel. It is not intended to replace the extensive training necessary to handle metering equipment in a safe manner. Supplies and Tools Required Physical Installation of the Landis & Gyr S4 MTU/Electric Meter Assemblies into compatible meter sockets can be accomplished without the use of tools. 471-2041 – 2/13/2007 Testing of the meter socket, however, may require specialized equipment. Check with the local electric utility for required testing procedures. Page 169 MTU Instruction for Landis & Gyr S4 MTU/Electric Meter Assembly Installation Procedure Step 1 – Complete all test procedures required by the local electric utility and verify that the meter socket has been correctly installed and wired. Step 3 – Place the meter/MTU assembly into the meter socket, carefully aligning the contact blades with the corresponding jaws in the meter base. Step 4 – Make a final visual inspection to ensure that the meter/MTU assembly is seated, sealed properly, and receiving power. Step 5 – Installation is now complete, program the MTU using the STAR Programmer Software and your Field Programmer. When programming the integral MTU mounted in this meter, hold the programming probe at the 3 o’clock position as shown here. Step 2 – If applicable, remove the existing meter assembly from the meter socket. Page 170 MTU Instruction for DFW Rectangular Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a New Flatpak STAR MTU to a rectangular DFW composite pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 4712000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item MTU Long Spacers (for pit lid mounting of New Style Flatpak MTUs) #10 x 2 1/2” Phillips Pan Head Type AB Stainless Steel Sheet Metal Screw Tools Required To mount the MTU to these DFW pit lids, you will need the following tools and equipment: • • • • Safety goggles #3 Phillips driver bit 3/32” drill bit Cordless Drill 3/8”, variable speed, with adjustable torque settings. 471-2042 - 11/9/2006 Part Number As required for installed meter 056-8150L Quantity 2 per MTU installation 2 per MTU installation Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Page 171 MTU Instruction for DFW Rectangular Composite Pit Lids Installation Procedure Step 2 - Place plastic spacers under the mounting tabs on the MTU as shown below, and attach the MTU to the pit lid with the 2 ½” stainless sheet metal screws. Insert the screws through the mounting holes and spacers and into the pre-drilled pilot holes. Mounting a New Flatpak STAR MTU to a rectangular DFW composite pit lid. Step 1 – Place the lid top down and use a template to mark and drill two pilot holes in the bottom surface of the pit lid as shown below. Note: A paper template is included in this document. The spacing between the two holes must be 6.81” (6 13/16”). The pilot holes should be along the solid ridge running across the pit lid as shown, positioned away from the finger hole. Page 172 Be sure to use the long spacers (Hexagram Part Number 056-8150L). You will note that one end of the spacers has a semi-circular ridge that mates with the mounting tabs on the MTU. MTU Instruction for DFW Rectangular Composite Pit Lids Be sure to position the MTU as shown, with the top (antenna) section of the MTU positioned in the approximate center of the lid. Template Torque screws to approximately 8 in-lbs. The MTU should be snug and suspended by the spacers above the bottom surface of the pit lid by approximately ½”. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 3 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 4 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. Page 173 MTU Instruction for DFW Rectangular Composite Pit Lids Intentionally Left Blank Page 174 MTU Instruction for Carson Industries 1015-5 Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Carson Industries Polyplastic Model 1015-5 pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item Quantity Long Plastic Zip Ties Electric Drill Part Number As required for installed meter Source locally Source locally ¼” Drill Bit Source locally MTU Flatpack - Model 8150 471-2043 - 3/27/2009 Page 175 MTU Instruction for Carson Industries 1015-5 Pit Lids Tools Required To mount the MTU to the Carson pit lids, you will need the following tools and equipment: • • • • Safety goggles Long plastic zip ties 1/4” standard drill bit Cordless Drill with variable speed and adjustable torque settings Note on setting the torque range: On a drill that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill. This should amount to approximately 8 in-lbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Installation Procedure Step 1 – Drill a hole through the left and right center ribs of the pit lid. The hole should be approximately one inch from the center of the lid and about ½ inch from the top of the rib. Page 176 Step 2 – Position the MTU with the label side face down against the underside of the pit lid. The mounting tabs of the MTU should be aligned with the center ribs with the newly drilled holes. Ensure that the metal hinge of the pit lid view door is below the bottom of the MTU. MTU Instruction for Carson Industries 1015-5 Pit Lids Step 3 – Thread plastic zip ties through each of the drilled rib holes and through the holes of the MTU mounting tabs. Step 4 – Gently pull through the zip ties so that the MTU is secured to the pit lid. Do not over tighten the zip ties. Excessive torque may bend the mounting tabs and break the seal of the MTU. There should be a little movement with the MTU once the zip ties have been sufficiently tightened. Step 5 – Once secured, remove the unnecessary length from the zip tie ends. Page 177 MTU Instruction for Carson Industries 1015-5 Pit Lids Step 6 – The MTU STAR logo should be visible through the pit lid view door after proper placement and mounting. CAUTION! Do not over tighten the zip ties when mounting the MTU. Excessive torque can bend the MTU mounting tabs. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 7 – Wire the MTU to the meter, folding and forming wires into valve box as necessary so that they do not interfere with lid locking mechanism and cannot become pinched. Step 8 – Installation is now complete. You can now proceed to program the MTU using the STAR Field Programmer Software and your Field Programmer. Page 178 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on Rockwell/Equimeter/Sensus MR-8 residential gas meters. Parts Required Ref. # 10 11 Item Gasket Coupler, MTU Retaining Shaft, MTU MTU, Direct Mount Magnet Gear/magnet holder 10-24 x 1 1/8” Slotted, Fillister Head Machine Screw #6 Round Spacer, Nylon #6 x 1 1/4” Combo Panhead Sheet Metal Screw Register Cover, MTU #10 x 1” Combo Panhead Sheet Metal Screw 471-2044 - 4/8/2007 Part Number 066-5155C 056-13183A 056-5155D 501-6327/7712 036-0002 056-13183B 069-102436HA 068-60812-EX 069-060040C3A 109-7712A 069-100032C3A Quantity Page 179 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws. Discard the screws and cover. Step 2 - Remove the register by removing the two screws. Set the register aside. Discard the screws. Step 3 - Insert the four 10-24 x 1⅛” screws through the holes on the MTU as shown. Page 180 Step 4 – Turn the MTU over and place the gasket on the back of the MTU so that it aligns over the four screws, as shown. Step 5 - Position the MTU on the meter. Rotate the coupler so that the gear tooth on the coupler engages with the gear teeth on the gas meter. Orientation is not critical, but you should be able to feel the teeth “bite” when you turn the coupler from the front of the MTU. Step 6 - Tighten the four 10-24 x 1-⅛” screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Tighten corner to corner. Step 7 - Check the coupler. It should have slight play — it should not bind or turn too freely. MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on steps 9-12. Step 10 - After you feel engagement between the index register gear and the MTU coupler gear, tighten the register screws until they are snug. Step 8 - On the register, insert the screws and spacers. Step 9 - Mount the register to the MTU, fastening it to the mounting holes shown below. Hand tighten to a torque not to exceed 3-5 inch-pounds. Make sure the index register gear and the MTU coupler gear are engaged. Step 11 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly. Step 12 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Step 13 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Page 181 MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Intentionally Left Blank Page 182 MTU Instruction for Mid-States 12" Round Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Mid-States 12” Round Pit Lid (Model Number MS-IL1-SN). This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item MTU Flatpack - Model 8150 Adjustable lid bracket #10-32 x 1-3/4” Phillips pan-head machine screw, stainless #10-32 x ½” Phillips pan-head machine screw, stainless Short Spacers Tools Required To mount the MTU to 12” round MidStates pit lids, you will need the following tools and equipment: • • • Safety goggles Cordless Drill with variable speed and adjustable torque settings #2 Phillips power screwdriver bit 471-2045 - 4/10/2007 Part Number As required for installed meter 056-8150H 069-103256AS 069-103216AS 056-8150S Quantity Note on setting the torque range: On a drill that has about 20 settings (positions) set the adjustment to #6. Use the lower speed range of the drill. This should amount to approximately 8 in-lbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs. Page 183 MTU Instruction for Mid-States 12" Round Pit Lids Installation Procedure Step 1 – Place the pit lid top-side down on a solid surface, positioning the metal latch nearest to you as shown in the photo below. Step 2 – Pre-assemble the MTU, spacers and bracket as shown below, using the two #10-32 x 1-3/4” machine screws through the back of the MTU mounting tabs and spacers. Thread the bracket onto the screw at the left side of the MTU Page 184 Step 3 – Turn the MTU face down onto the bottom surface of the pit lid positioning it as shown below. Align the slot in the bracket with the mounting post at the top right and insert the #10-32 x ½” machine screw. Then tighten all hardware to approximately 8 in-lbs. Step 4 – Here’s another view of the finished assembly. Note the position of the bracket. MTU Instruction for Mid-States 12" Round Pit Lids Step 5 – Wire the MTU to the meter, bundling the excess wire as necessary so that it does not interfere with lid locking mechanism and cannot become pinched when the lid is placed on the pit. Step 6 – Installation is now complete. You can now proceed to program the MTU using the STAR Field Programmer Software and your Field Programmer. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Page 185 MTU Instruction for Mid-States 12" Round Pit Lids Intentionally Left Blank Page 186 MTU Instruction for Alliance Rectangular Pit Lids Purpose & Scope This instruction provides a procedure for temporarily mounting a STAR Flatpak MTU to a Alliance Rectangular Pit Lid (illustrated below). This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions. Parts Required Item Quantity Long Plastic Zip Ties Electric Drill Part Number As required for installed meter Source locally Source locally ¼” Drill Bit Source locally MTU Flatpack - Model 8150 Tools Required To mount the MTU to the Alliance rectangular pit lids, you will need the following tools and equipment: • • • • Safety goggles Long plastic zip ties 1/4” standard drill bit Cordless Drill with variable speed and adjustable torque settings Installation Procedure Step 1 – Drill two holes through ribs on the bottom of the pit lid as shown below. Each hole should be approximately ½ inch from the top of the rib 471-2046 - 5/21/2007 Page 187 MTU Instruction for Alliance Rectangular Pit Lids Step 2 – Position the MTU with the label side face down against the underside of the pit lid and thread plastic zip ties through each of the drilled holes and through the holes of the MTU mounting tabs. Step 3 – Gently pull through the zip ties so that the MTU is secured to the pit lid. Do not over tighten the zip ties. Excessive torque may bend the mounting tabs and break the seal of the MTU. Tighten only until the MTU contacts the lower surface of the pit lid. Trim the excess length from the zip tie ends. CAUTION! Do not over tighten the zip ties when mounting the MTU. Excessive torque can bend the MTU mounting tabs. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 4 – Wire the MTU to the meter, forming wires as necessary so that they do not interfere with lid locking mechanism and cannot become pinched. Step 5 – Installation is now complete. You can now proceed to program the MTU using the STAR Field Programmer Software and your Field Programmer. Page 188 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Actaris/Sprague/Schlumberger residential gas meters: 1A, 175, and 240 (Flatface). Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Ref. # 10 Item Adaptor 10-24 x .75” Phillips pan head machine screw, zinc Gasket MTU, Sprague Direct Mount Tall Magnet Coupler Coupler Shaft Register Coupler #10 x 3/8” combo head thread form screw, Type A, zinc Clear Register Cover 10-24 x 2” slotted fillister head machine screw, zinc 471-2047 - 7/18/2007 Part Number 056-12705A 069-102424A 066-11583 per project 056-12705B 056-5155D 056-11583D 069-100012C3A 056-12705C 069-102464HA Quantity Page 189 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • #2 Phillips screwdriver • ¼” Slotted screwdriver • 2 alignment studs – Hexagram part number xxx-yyyy Step 3 – Mount the adaptor to the meter head using the two #10-24 x .75” provided. Tighten these screws to a torque not to exceed 15 -18 inch-pounds. Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the screws that hold it. Discard the screws and the cover. Step 2 - Remove the register by removing the two screws that hold it. Set the register aside and discard the screws. Page 190 Step 4– Remove the paper backing from the gasket provided to expose the pressure sensitive adhesive. Place the gasket on the back of the MTU with the adhesive surface facing the MTU so that it aligns over the three mounting screws and the raised gasket surface of the MTU. MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 5 – Next, assemble the couplers and shaft to the MTU. Place the flat, disc-shaped coupler on the shaft and insert the shaft through the front (register) side of the MTU. Tighten both screws to a torque not to exceed 3-5 inch-pounds. Then snap the magnet holder on the shaft from the back of the MTU. Ensure that both couplers are firmly attached to the shaft. Step 6 – Now, mount the register onto the MTU (see illustration below) fastening the register to the MTU with the #10 x 3/8” screws provided. CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Use of power tools is not recommended. Step 7 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Start the two screws into the mounting holes, and then slide the register beneath the screws, making sure that the wiggler on the register is aligned with the MTU coupler. Page 191 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 8 – Next, thread alignment studs into the threaded mounting holes on the left and right side of the adaptor, as shown below. Step 10 – Now, slide the clear register cover over the alignment studs while you hold the MTU in position with your free hand. Step 11 - Next, insert one of the #10-24 x 2” screws through the top-center hole on the clear register cover. Tighten this screw just sufficiently to hold the MTU and register cover to the meter. Step 9 – Next, slide the MTU over the alignment studs, positioning the coupler on the MTU to ensure that it engages correctly with the wiggler on the gas meter. Page 192 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 12 – Next, remove one of the alignment studs and replace it with another one of the #10-24 x 2” screws provided. Continue in a similar manner, replacing the other alignment stud with a #10-24 x 2” screw. Tighten all three screws to a torque not to exceed 12 -15 inch-pounds. The gasket should be compressed slightly. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure. Because of this, power tools are not recommended for this procedure. Step 14 – Once Installation is complete, program the MTU using your field programmer and the STAR Programmer Software. Step 13 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Page 193 MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Intentionally Left Blank Page 194 MTU Instruction for Actaris Dattus Gas Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Actaris Dattus fm2 & fm3 Commercial and Industrial Gas Meters. Notes: • The pulse output of the Dattus meter can be customer configured. For successful operation with a STAR MTU, the pulse rate must be configured so as not to exceed 3 pulses per second at the maximum flow rate supported by the meter. 471-2051 - 6/9/2008 Page 195 MTU Instruction for Actaris Dattus Gas Meters Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Connect the MTU cable to the Dattus Pulse Ouput cable according to the table below. MTU Cable Dattus Pulse Output Cable Red Red (Channel 1 +) Black Green (Channel 1 -) White Green (Channel 1 -) Page 196 Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for Severn Trent Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Severn Trent Water Meters. Step 2 – Connect the MTU cable to the meter cable according to the table below. MTU Cable Meter Cable Red Red Black Black White Green Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. 471-2052 - 6/9/2008 Page 197 MTU Instruction for Severn Trent Water Meters Intentionally Left Blank Page 198 MTU Instruction for Endress & Hauser PROMAG Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Endress & Hauser PROMAG Water Meters. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. 471-2053 - 3/17/2009 Notes: • The pulse output of the PROMAG is configurable. For successful operation with a STAR MTU, the pulse rate must be configured so as not to exceed 3 pulses per second at the maximum flow rate supported by the meter. Page 199 MTU Instruction for Endress & Hauser PROMAG Water Meters Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Connect the MTU cable to the terminal strip located .under a cover plate around to the right of the meter display. (See the photo and wiring table below.) MTU Cable PROMAG Terminal Strip Red Terminal #24 (+) Black Terminal #25 (-) White Terminal #25 (-) Page 200 Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. MTU Instruction for Actaris Cyble Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Actaris Cyble Water Meters. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Connect the MTU cable to the Cyble or Cyble Coder cable as shown in the tables below. 471-2054 - 6/22/2008 Cyble Sensor (Pulser) MTU Cable Cyble Sensor Cable (Grey Jacket) Red Brown Black White White White Connect to an “R” type STAR MTU Port. Page 201 MTU Instruction for Actaris Cyble Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Cyble Coder MTU Cable Cyble Coder Cable (Black Jacket) Red Red Black Black White Green Connect to a “D” type STAR MTU Port. Note: The Cyble Coder must be configured for a 6-digit reading Page 202
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : afertal Create Date : 2009:09:28 14:45:58-04:00 Modify Date : 2010:08:18 08:42:18-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2010:08:18 08:42:18-04:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Microsoft Word - All MTU Instructions 10-1-2009 TOC.doc Creator : afertal Document ID : uuid:ef557ec4-f0a5-433c-bb4a-76142d982f59 Instance ID : uuid:b1d6e47d-a821-4f7f-9e6f-0ca34ceace14 Producer : Acrobat Distiller 7.0.5 (Windows) Page Mode : UseOutlines Page Count : 202EXIF Metadata provided by EXIF.tools