Aclara Technologies 2017021 Itron/Sprague Gas MTU User Manual

Aclara Technologies LLC Itron/Sprague Gas MTU

User Manual

1Sprague/Actaris Gas MTU Installation InstructionsItron (Sprague/Actaris) Gas MeterMTU Installation Instructions (Y20972-TUM Rev A)FCC/ISED ComplianceThis product/device has been tested and certified to be in compliance with all appropriate requirements of both the FCC and ISED.Any changes or modification to this product/device, or the use of any antenna other than the one provided by or authorized with expressed written approval by Aclara Technologies LLC may void the user’s authority to operate this product/device. This product/device and/or its antenna must be fixed-mounted on indoor or outdoor permanent structure(s) providing a separation distance of at least 20 cm from all persons during normal operation.  This device is not designed (and it has no external connection) to operate in conjunction with any other antennas or transmitters.  No other operating instructions for satisfying RF exposure compliance are needed.This product/device has been tested and calibrated at the factory. It has no user adjustable controls and can only be adjusted by authorized, trained personnel. French translation:Conformité FCC/ISDECet équipement a été testé et il est conforme à toutes les exigences appropriées de la FCC et de l’ISDE.Tout changement ou toute modification à cet appareil, ou l’emploi de n’importe quelle antenne autre que celle fournie par ou autorisée sous l'accord exprès donné par écrit d'Aclara Technologies LLC peut annuler l'autorisation d'utiliser de cet appareil.Cet appareil ainsi que son antenne doivent être montés de manière fixe sur des structures intérieures ou extérieures permanentes en conférant une distance d’au moins 20 cm des personnes pendant le fonctionnement normal. Cet appareil n'est pas conçu (et il n'a aucun branchement externe) pour être utilisé en association avec toute autre antenne ou tout émetteur. Aucune autre instruction d'utilisation n'est requise pour assurer la conformité aux règles d'exposition aux RF.Cet appareil a été soumis à des tests et calibré en usine. Il n’a pas de contrôle d’ajustement et ne peut être ajusté que par un personnel autorisé et qualifié.The information contained in this document is private to Aclara Technolgies LLC an Ohio liability company (Aclara). This information may not be published, reproduced, or otherwise disseminated without the express written autorization of Aclara. Any software or firmware described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. The information in this document is subject to change without notice and should not be construed as a commitment by Aclara. Aclara assumes no responsibility for any errors that may appear in this document. No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Aclara. STAR is a registered trademark of Aclara Technologies LLC.
2 Sprague/Actaris Gas MTU Installation InstructionsPurpose & ScopeThese instructions provide a procedure for installing a STAR direct-mount MTU on the Sprague 175, 240, 250, 400, Metris 250, and 400A Itron Gas Meters. This installation instruction covers the Aclara Catalog number 3551-031-RBS2W/3551-031-RBS2. (The images in this document are for reference only.)Parts RequiredNOTEThe mounting kit contains the exact quantity of hardware required for a single installation. Keep extra hardware on hand.NOTENo repair or maintenance of MTU is required. Defective MTU will be replaced.NOTEMTU may be wiped with damp cloth to prevent electrostatic charge hazard.Item # Item Description Qty1 Series 3500 Direct Mount MTU 12 #10-24 X 1.5" Stainless steel screw 33 #10-24 X 5/8” Stainless steel set screw 24 #10 X 1/2” Stainless steel screw 45 #10-16 X 1/2” Stainless steel screw 26 Security seal 4
3Sprague/Actaris Gas MTU Installation InstructionsTools RequiredTo mount the MTU to these meters, you will need the following tools and equipment:• Phillips screwdriver• Slotted screwdriver• Torque-limiting screwdriver• 3/32” hex key wrench• Safety glassesRemove Index1.  Remove all anti-tamper, safety, and security hardware from the clear index cover.2. Remove the existing clear index cover by removing the three screws securing it to the meter. Discard the screws and the cover.NOTE: If more than one screw is broken, DO NOT install the MTU.
4 Sprague/Actaris Gas MTU Installation Instructions3. Remove the index by removing the two screws securing it to the meter.Discard the screws.NOTE: If either of the screws break during removal, DO NOT install the MTU.4. Remove the gasket and any adhesive residue on the meter.Mount Index to MTU1.  Ensure that the coupler is properly engaged with the gear shaft and that the magnet is present.
5Sprague/Actaris Gas MTU Installation Instructions2. Verify that the pre-applied gasket is properly adhered to the back of the MTU.3. Mount the index onto the MTU by starting two #10-16 x 1/2” stainless steel screws into the two holes on the front of the MTU.4. Slide the index beneath the heads of both screws and align the MTU coupler pin to the index dial gear.Metris Meter
6 Sprague/Actaris Gas MTU Installation Instructions5. Tighten both screws to 10-12 inch-pounds.6. Rotate the gear on the back of the MTU in both directions, and verify that the index dials turn smoothly.Sprague Meter
7Sprague/Actaris Gas MTU Installation InstructionsMount MTU Assembly to Meter1.  Thread the two #10-24 x 5/8” alignment screws two turns into the holes in the meter.2. Position the pilot holes on the back of the MTU over the alignment screws.3. Secure the MTU/index assembly to the meter using the three #10-24 x 1.5" screws. Tighten to 10-12 inch-pounds.
8 Sprague/Actaris Gas MTU Installation Instructions4. Align the magnet in the new index cover to the recess in the MTU.5. Secure the cover to the MTU using the four remaining #10 x 1/2” screws. Tighten each screw to 10-12 inch pounds.6. Install the four anti-tamper plugs in the index cover screw towers.Putting the Device into ServiceProgram the MTU using the STAR ProgrammerTo take the device out of service, follow the steps in the STAR Programmer in reverse order.MTU ID Label Examples
9Sprague/Actaris Gas MTU Installation InstructionsNOTESpecific Conditions of use in hazardous locations indicated on label.List of Standards1.  ANSI/ISA 12.12.012. CSA 22.2NOTE Training can be provided by Aclara or Aclara can train and certify third party installers. Installers may be anyone certified by Aclara.
10 Sprague/Actaris Gas MTU Installation Instructions