Aclara Technologies Y84000 Synergize RF network utility I210+ meter transponder User Manual SRFN GE I 210

Aclara Technologies LLC Synergize RF network utility I210+ meter transponder SRFN GE I 210

Users Manual

www.Aclara.comIntegration ManualY20454-INT Rev. A®PROPRIETARY NOTICEThe information contained in this document is private to Aclara Technologies LLC, an Ohio limited liability company  (Aclara).  This information may not be published, reproduced, or otherwise disseminated without the express written authorization of Aclara.  Any software or firmware described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.DISCLAIMERThe information in this document is subject to change without notice and should not be construed as a commitment by Aclara.  Aclara assumes no responsibility for any errors that may appear in this document.  No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Aclara.  TWACS,  STAR, and Metrum Cellular are registered trademarks of Aclara Technologies LLC.Synergize™  RF NetworkGE I-210   DRAFT 8-27-2015
 DRAFT 8-27-2015
Synergize™ RF Network GE I-210 Integration Manual 1FCC ComplianceThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference consult Aclara Support for help.Safety InformationThe following safety precautions must be observed during all phases of operation, service, and repair of this device. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and the intended use of the metering instrument. Aclara assumes no liability for the customer’s failure to comply with these requirements. WARNINGAny work on, or near, energized meters, meter sockets, or other metering equipment can present a danger of electrical shock. All work on this product should be performed only by qualified electricians and metering specialists in accordance with local utility safety practices, utility requirements and procedures outlined in Chapter 14 of The Handbook for Electricity Metering (10th edition). The information contained within this manual is intended to be an aid to qualified metering personnel. It is not intended to replace the extensive training necessary to handle metering equipment in a safe manner. • Use care when servicing with the power on.• Do not assume neutral (white lead) is always at earth ground potential. Some services have this connection at line voltage.• Be aware that dangerous voltages exist at several points within the meter when this product is installed on a meter base. • Disconnect power before meter disassembly, soldering, or replacing components. The meter is connected directly to line potential. Due to the possibility of the potential lines being reversed, points accessible with the cover off may be at line voltage. Consult the meter instruction/technical manual for meter specific information.DRAFT 8-27-2015
2Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter IntegrationSynergize™ RF Network GE I-210 Meter IntegrationThis document provides an overview of the material and steps required to integrate an Aclara Synergize™ RF Network endpoint module with a new or existing GE I-210 meter. Components NeededI-210 Integration1.   Put on an ESD strap.2.   Remove the meter cover.• Antenna•Meter• Bridge• Bridge Screws• RF board• Antenna holder• Bushings/Stand-offs• Bushing/stand-off screwsDRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  33.   Remove the top of the meter by squeezing the pair of clips on each side of the meter.4.   Disconnect the remote disconnect wire from the top of the meter, if the meter has the remote disconnect option, DRAFT 8-27-2015
4Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter Integration5.   Remove the red remote disconnect wire from the metal clip on the meter base.6.   Remove the black remote disconnect wire from the metal clip on the meter base.DRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  57.   Attach the longer red and black remote disconnect wires as shown in the following image.8.   Verify the GE-supplied bridge is properly positioned on the meter base.DRAFT 8-27-2015
6Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter Integration9.   Secure the bridge to the meter base using the two screws.NOTEIf the meter has the remote disconnect option, carefully pull the remote disconnect wire underneath the bridge so it can be properly routed in Step 12.10.  Remove the backing from the antenna.DRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  711.  Affix the antenna to the antenna holder.NOTEWhen applying the antenna, maximum bond strength can be obtained by thoroughly cleaning and drying the surface of the antenna holder with isopropyl alcohol. For applications such as this, it is important to use reagent grade solvents. Common household materials, such as rubbing alcohol, frequently contain oils to minimize the drying affect on skin, and can interfere with the performance of a pressure-sensitive adhesive.DRAFT 8-27-2015
8Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter Integration12.  Place the antenna holder over the posts on the bridge.NOTEIf the meter has the Remote Disconnect option, make sure the Remote Disconnect wire is routed between the bridge and the antenna holder.DRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  913.  Install the RF board over the bridge posts.14.  Place the bushings/standoffs over the bridge posts.DRAFT 8-27-2015
10 Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter Integration15.  Secure the bushings using the two screws.16.  Connect the antenna wire to the connector on the RF board.NOTEIt is not required, but a Plug Insertion Tool (HRS U.FL-LP-IN) is available for mating U.FL series plugs and receptacles.DRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  1117.  Align the 12 pin connector on the under-side of the meter top to the connector on the RF board.NOTEIf the meter has the remote disconnect option, align the connector on the remote disconnect wire to the connector on the underside of the meter top.DRAFT 8-27-2015
12 Synergize™ RF Network GE I-210 Integration ManualSynergize™ RF Network GE I-210 Meter Integration18.  Press the top of the meter into place. Ensure the retaining tabs lock in place.19.  Place the MAC ID label above the LCD and place the FCC label below the LCD as shown in the following image.20.  Reinstall the meter cover.MAC ID LabelFCC LabelDRAFT 8-27-2015
Synergize™RF Network GE I-210 Integration Manual  13SupportThere are several ways to get help when you have a question, an issue, or would like to speak with Aclara’s Support personnel. • Aclara ConnectAclara's exciting customer portal (https://connect.aclara.com) enables you to access our frequently-updated knowledge database, easily access product documentation, submit and track your Support cases and RMAs, access Aclara University's Online Learning Center (OLC) and learning library, track your orders, join communities and groups, join in discussions with other Aclara customers and Aclara personnel, and much more. If you do not have access to Aclara Connect, email support@aclara.com and request access.• Aclara UniversityAclara’s on-demand training makes content available to you in a convenient, cost-effective online environment. The OLC has recordings of several webinars, streaming educational videos, software simulations, and short videos which walk you through a specific task. Access the OLC by going the Training tab of Aclara Connect and clicking the Online Learning Center link.• Technical SupportEmail support@aclara.com or call 1-800-892-9008 to speak with an Aclara representative.DRAFT 8-27-2015
14 Synergize™ RF Network GE I-210 Integration ManualSupportDRAFT 8-27-2015
GE I210+ and I210+ with Remote Disconnect Integration Manual 15CHAPTER 0APPENDIX A: FORM & MODULE P/NSOnly the GE I-210 (JV103X677) meter forms listed below are qualified to be integrated with the Aclara Synergize™ RF Network module. Meter FormClass and VoltageAclara GE I-210+ ModulesAclara GE I-210+ RD Modules Kh Value1S CL100, 120V Y84024-1 Y84024-301 1.0CL100, 240V Y84024-1 Y84024-301 1.01SRD CL100, 120V Y84024-1 Y84024-301 1.02S CL200, 240V Y84024-1 Y84024-301 1.0CL320, 240V Y84024-1 Y84024-301 1.02SRD CL200, 240V Y84024-1 Y84024-301 1.03S CL20, 240V Y84024-1 Y84024-301 1.04S CL20, 240V Y84024-1 Y84024-301 1.012S CL200, 120V Y84024-1 Y84024-301 1.0CL320, 120V Y84024-1 Y84024-301 1.012SRD CL200, 120V Y84024-1 Y84024-301 1.025S CL200, 240V Y84024-1 Y84024-301 1.0DRAFT 8-27-2015
16 GE I210+ and I210+ with Remote Disconnect Integration ManualDRAFT 8-27-2015
Synergize™ RF Network GE I-210 Integration Manual 17CHAPTER 0APPENDIX B: WIRING DIAGRAMS6 63636636363DRAFT 8-27-2015
18 Synergize™ RF Network GE I-210 Integration ManualDRAFT 8-27-2015
NOTICE: This device is certified by the Federal Communications Commission for use pursuant to a station authorization. TWACS®, STAR®, and Metrum Cellular® are registered trademarks of Aclara Technologies LLC an Ohio limited liability company (Aclara). All software is property of Aclara. Patents issued and pending. Aclara reserves the right to change the specifications on this product without prior notification. Copyright Aclara Technologies LLC 2015.Synergize™ RF Network Endpoint ModuleElectrical SpecificationsEnvironmental SpecificationsPhysical SpecificationsCompliance SpecificationsParameter RatingInput Voltage 4.0 VDC or optional 28VDCQuiescent Current 70 mA @ 4 VDCCurrent while transmitting RF <800 mA @ 4 VDC Power Supply DC energy is provided by the hostParameter RatingEffect of Operating Temperature Aclara specific test-40° C to 70° C with and without solar loadEffect of Relative Humidity Aclara specific test60° C for thee 24 hour cycles or 85° C for one 24 hour cycle at 95± 4% relative humidity, non-condensingTest  Ti tle SpecificationApproximate weight < 3 oz.Dimensions IrregularTest  Ti tle SpecificationEMI/RFI Emission - Conducted/RadiatedFCC 15.107 Conducted Emissions IEC CISPR 22FCC 15.109 Unintentional Radiator IEC CISPR 22EMI/RFI Susceptibility RF Susceptibility ANSI C12.1 Test #26 200 kHz to 10 GHz 20 V/mFCC Part 90 Subpart I, emission mask DOccupied Bandwidth 11.25 kHzRF Output Power <+30 dBmTransmit duty cycle < 2% Carrier Frequency Stability ± 2.5 ppm Note: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This product complies with FCC OET Bulletin 65 & Industry Canada's RSS-102 radiation exposure limits set forth for an uncontrolled environment.Aclara Technologies LLC low power RF devices and their antennas must be fixed-mounted on indoor or outdoor permanent structure(s) providing a separation distance of at least 20 cm from all persons during normal operation. This device is not designed (and it has no external connection) to operate in conjunction with any other antennas or transmitters. No other operating instructions for satisfying RF exposure compliance are needed.

Navigation menu