Actiontec Electronics SG200 Gateway Device with 802.11n and Z-Wave Home Control User Manual SG200 SG200B QSG

Actiontec Electronics Inc Gateway Device with 802.11n and Z-Wave Home Control SG200 SG200B QSG

Quick Start Guide

1ActiontecElectronics,Inc.760NorthMaryAve.,Sunnyvale,CA94085USAGatewayDevicewith802.11nandZ‐WaveHomeControlModel#:SG200andSG200Rev.BQuickStartGuideVersion:0.0(Drafttobereview)
2ConnecttheSG200/SG200Rev.BGatewaytoPowerandRouter1. PlugoneendoftheEthernetcabletotheEthernetportontheSG200/SG200Rev.Bgateway.2. PlugtheotherendoftheEthernetcableintotheLANportonthebackofyourrouter.3. PlugtheACpoweradapterconnectortotheSG200/SG200Rev.Bgateway’spowerport. (Power:External,10VDC,1.6AmadebyAdapterTechnologyCo.,Ltd.;Model:STD‐10016U)4.Nowplugthepoweradapterintoaproperlygroundedpoweroutlet.5.MakesurethepowerLEDlightontheGatewaydeviceisgreen.6.YourEthernetLEDlightisgreeniftheEthernetcableisconnected.ConnecttheSG200/SG200Rev.BtoRouterWirelessly(Optional)1. FindouttheIPaddressoftheSG200/SG200Rev.BGateway.UsuallyyoucandothisbylookinguptheDHCPclientlistfromtherouter’swebpage.Let’sassumeitis192.168.1.2.2. UsingacomputerwithaSSHclient,connecttotheSG200/SG200Rev.BGateway.a. ForWindowscomputers,PuttyisagoodSSHclientprogram.ConfigurePuttyusingitsGUIandentertheIPaddressas192.168.1.2andport22,thenhittheconnectbutton.b. ForLinuxcomputers,openaterminalandenter“sshroot@192.168.1.2”.3. Ifpromptedforusername,enter“root”.Thereisnopassword.4. Createaconfigurationfile.Typethiscommandvi/config/wpa_supplicant.confEnterthefollowinginformationinsidethevitexteditor.Enter“i”tostarttheeditingmode.network={ssid="Your_Access_Point's_SSID"psk="Your_WPA_or_WPA2_Passphrase"}Press“ESC”toexittheeditingmode.Savethefilebytyping“:wq!”.5. Nowconnecttotherouter.Typethecommandwpa_supplicant–Dwext–iwlan0–c/config/wpa_supplicant.conf–B6. GetanIPfromtherouter.Typethecommanddhclientwlan0Ifyouseeamessagesimilarto“boundto192.168.1.3‐‐renewalin35739seconds.”thatmeansyouaresuccessfullyconnected.NotethisinstructionworkswithWPAorWPA2encryptedwirelessnetworksonly.Congratulationsyouarenowconnected!
3Specifications1. Features• CompliantwithIEEE802.3Ethernetstandard.• Supports100BaseTand1000BaseT.• 2.4GHzIEEE802.11nDraft‐compliant• 2‐streamspatialmultiplexingupto135Mbps• Supports20MHzchannels• FullIEEE802.11b/g/nlegacycompatibilitywithenhancedperformance• ComprehensivewirelessnetworksecuritysupportthatincludesWPA,WPA2,andAESencryption/decryptioncoupledwithTKIPandIEEE802.1Xsupport• 802.11bDataRates:11Mbit/s,5.5Mbit/s,2Mbit/s,1Mbit/s(And22Mbit/swithPBCC);• 802.11gDataRates:6Mbit/s,9Mbit/s,12Mbit/s,18Mbit/s,24Mbit/s,36Mbit/s,48Mbit/s,54Mbit/s.2. Powerrequirements• Operatingvoltage: +10VDC@1.6Amax3. EnvironmentalOperatingRange• Operatingtemperature: 0ºCto40ºC(32ºFto104ºF)• Humidity:  5‐95%,non‐condensing4. DimensionandWeight• 7”(L)x5.5”(W)x1.5”(H)0.65lb.5. Certifications• FCCPart15ClassBandClassC;UL
General Regulatory and Compliance NoticesImportant Safety InstructionsIf applicable,when using telephone equipment,basic safety precautions should always be followed to reduce the risk of fire,electricalshock,and personal injury,including the following:•Do not use this product near water – for example,near a bathtub,kitchen sink,laundry tub,or swimming pool,or in a wet basement;•Avoid using a telephone (other than a cordless type) during an electrical storm,as there may be a remote risk of electrical shockdue to lightning;•Do not use the telephone to report a gas leak in the vicinity of the leak;•Use only the power cord and batteries indicated in this manual;•Do not dispose of batteries in fire,as they may explode – check with local codes for possible special disposal instructions.Telephone Line Cord CautionTo reduce the risk of fire, use only No. 26 AWG or larger (e.g.,24 AWG) UL Listed or CSA CertifiedTelecommunication Line Cord.Coaxial CableIf applicable, the coaxial cable screen shield needs to be connected to the Earth at the building entrance per ANSI/NFPA 70,the National ElectricalCode (NEC),in particular Section 82093,“Grounding of Outer Conductive Shield of a Coaxial Cable,”or in accordance with local regulation.FCC Class B EquipmentThis equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmfulinterference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off andon,the user is encouraged to try and correct the interference by implementing one or more of the following measures:•Reorient or relocate the receiving antenna;•Increase the separation between the equipment and receiver;•Connect the equipment to an outlet on a circuit different from that to which the receiver is connected;•Consult the dealer or an experience radio or television technician for help.ModificationsThe FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved byActiontec Electronics,Inc, may void the user’s authority to operate the equipment.Declaration of conformity for products marked with the FCC logo – United States only.This devices complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:1.This device may not cause harmful interference;2.This device must accept any interference received,including interference that may cause unwanted operation.Important NoteIf applicable,this equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipmentshould be installed and operated with minimum distance 20 cm between the radiator and your body.The transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.For questions regarding your product or the FCC declaration,contact:Actiontec Electronics,Inc760 North Mary Avenue, Sunnyvale,CA 94086,United StatesTel:(408) 752-7700 Fax:(408) 541-9005PN 0530-0601-100 PI1022/0210

Navigation menu