Adams Rite 80 0180 309_K 7400 Series Electric Strikes Installation Instructions ES7400 309 K
User Manual: Adams Rite 7400 Series Electric Strikes Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS (SEE FIG. 1) 7400 ALUMINUM DOOR JAMBS 1. PREPARE DOOR JAMB/STILE PER DRAWING. 7410 ALUMINUM JAMBS 7430 ALUMINUM DOOR JAMBS D 2. INSTALL MOUNTING CLIPS TO JAMB/STILE USING 8-32 X 3/8 SCREWS & PRESSED METAL NUTS. LEAVE SCREWS SLIGHTLY LOOSE TO PERMIT EASY ALIGNMENT OF CASE ASSEMBLY & CLIPS. 3. SPACERS ARE PROVIDED TO ASSURE FLUSH FINAL ASSEMBLY OF FACE PLATE & JAMB/STILE. ADD ONE OR MORE SPACERS BETWEEN JAMB/STILE & MOUNTING CLIP WHEN FACE PLATE EXTENDS BEYOND THE JAMB/STILE. WHEN THE FACE PLATE SETS INSIDE THE JAMB/STILE, SPACERS MUST BE ADDED BETWEEN THE MOUNTING CLIP & THE ELECTRIC STRIKE FACE PLATE. SEE DETAIL "A" TO ATTACH SPACER TO MOUNTING CLIP. REMOVE PROTECTIVE COATING FROM SPACER & PRESS TO DESIRED MOUNTING CLIP SURFACE. MAKE SURE CLEARANCE HOLE IN SPACER ALIGNS WITH HOLE IN MOUNTING CLIP. 4. ATTACH SUBCOVER AND FACE PLATE TO THE CASE ASSEMBLY USING TWO 8-32 X 1/4 SCREWS. MOUNTING CLIP F 1.38 B C B G 7401 ALUMINUM STILE H D 7431 ALUMINUM A 74R1 STRIKE F H 7440 METAL JAMB G C G B CL D G C CL C H E B I A 74R1 & 74R2 A 74R2 METAL JAMB 7440 WOOD DOOR* A F INSIDE FACE OF CLOSED DOOR PRODUCT MUST BE INSTALLED ACCORDING TO ALL APPLICABLE BUILDING AND LIFE SAFETY CODES Rev. K CL A J D .375 F B E CL B G CL 7400 ELECTRIC STRIKE 80-0180-309 B H CL E Fax: 866-582-4641 800-232-7329 .375 F J C Phone: 800-626-7590 800-872-3267 J A J D E SHIM KIT 91-0096 OR 91-0097 www.adamsrite.com CL K E STILE H CL G FIG. 1 CL CL C G 70 FT-LB FORCE 500,000 CYCLES WIRE NUTS E F ENDURANCE PRESSURE SENSITIVE SPACER L D JAMBS CL 7. SECURE 8-32 MOUNTING CLIP SCREWS HOLDING MOUNTING TO JAMB. 1500 LBS. 7411 WOOD I 6. INSERT ELECTRIC STRIKE INTO JAMB AND ATTACH TO THE CLIPS USING TWO #12 COMBINATION SCREWS. DYNAMIC STRENGTH JAMBS E 5. USING WIRE NUTS PROVIDED, CONNECT WIRES COMING FROM THE STRIKE TO THE WIRES COMING FROM THE LOW VOLTAGE SIDE OF THE TRANSFORMER. STATIC STRENGTH 7410 WOOD J 1.38 C H D * REQUIRES WDC7400 A CL INSTALLATION INSTRUCTIONS ECN: 11970 Date: 07-25-12 Page 1 of 2 Appvd: BC Date: 07-26-12 FAIL-SAFE OPERATION (FIELD SELECTABLE) LOCKS WHEN ENERGIZED. USED IN APPLICATIONS REQUIRING AUTOMATIC UNLOCKING IN CASE OF POWER FAILURE. Control Switch (N.O.) (ex. Pushbutton, keypad,Card Reader) Control Switch (N.O.) (ex. Pushbutton, keypad, Card Reader) DRY CONTACTS! WIRE CODING (MONITORED VERSION) DRY CONTACTS! COLOR CODE: Red : NC White : NO Black : Common LATCH MONITOR AVAILABLE VOLTAGES 12V AC INTERMITTENT DUTY, 12V DC CONTINUOUS DUTY, 16V AC INTERMITTENT DUTY, *16V DC CONTINUOUS DUTY, 24V AC INTERMITTENT DUTY, 24V DC CONTINUOUS DUTY. TYPICAL ELECTRIC STRIKE WIRING DIAGRAM INTERMITTENT DUTY FAIL-SECURE 24 VAC ( * REQUIRES 16 VOLT ADAPTOR ) WARNING! AC INTERMITTENT DUTY SOLENOIDS ARE DESIGNED TO BE ENERGIZED 30 SECONDS AT A TIME MAXIMUM. ENERGIZING FOR LONGER PERIODS WILL DAMAGE THESOLENOID SOLENOID STATUS SWITCH TYPICAL ELECTRIC STRIKE WIRING DIAGRAM INTERMITTENT/CONTINUOUS DUTY 24 VDC SOLENOID CONNECTOR FIELD REVERSIBLE (FAIL SECURE) TO FAIL SAFE FAIL SECURE CONFIGURATION WIRING FAIL SAFE THE NUMBER OF WIRES WILL VARY DEPENDING ON FEATURES OF THE STRIKE. THE VOLTAGE AND AMPERAGE RATINGS ARE MARKED ON ALL STRIKE LABELS. THE SOLENOID WIRES ARE NOT POLARIZED. VOLTAGE ADAPTOR CABLE WIRE COLOR SEE TABLE BELOW MONITORING (OPTIONAL) FAIL SECURE TO FAIL SAFE ALL UNUSED LEADS FROM MONITOR SWITCHES SHOULD BE INSULATED. BLACK WHITE RED 5 AMPS @ 250 VAC TWO ADDITIONAL TRIGGER SHIMS ARE INCLUDED TO ACCOMODATE VARIABLE DOOR GAPS AND BOLTS. BROWN BROWN YELLOW YELLOW BLUE ORANGE BLUE BROWN 8Ω ORANGE 16V DC YELLOW BLUE ORANGE 24V AC/DC FOR WOOD DOOR APPLICATIONS FAIL-SAFE TO FAIL-SECURE SCREW (A) SCREW (B) STEP 1 LOOSEN SCREW (B) APPROXIMATELY 2 ROTATIONS, AND MOVE THE SLIDE TO THE LEFT AND TIGHTEN (DO NOT REMOVE SCREWS). STEP 2 LOOSEN SCREW (A) APPROXIMATELY 2 ROTATIONS AND SLIDE SCREW TO RIGHT AND TIGHTEN. 7400 ELECTRIC STRIKE 80-0180-309 SOLENOID WIRING DIAGRAM 12V AC/DC & 16V AC PRODUCT MUST BE INSTALLED ACCORDING TO ALL APPLICABLE BUILDING AND LIFE SAFETY CODES Fax: 866-582-4641 800-232-7329 FAIL SECURE MONITORED VERSION ONLY SHIM KIT P/N 91-0933 Phone: 800-626-7590 800-872-3267 LOOSEN SCREW (B) APPROXIMATELY 2 ROTATIONS, MOVE THE SLIDE TO THE RIGHT AND TIGHTEN. (DO NOT REMOVE SCREWS) FAIL SAFE CONFIGURATION 91-0098 www.adamsrite.com STEP 2 FIELD REVERSIBLE (FAIL SAFE) TO FAIL SECURE WARNING! INTERMITTENT DUTY SOLENOIDS SHOULD NOT BE CONVERTED TO FAIL-SAFE CONFIGURATION. FAIL SAFE UNITS SHOULD ONLY BE OPERATED WITH DC POWER SHIM PLATES ARE PRE-INSTALLED AT THE FACTORY. A THINNER SET OF SHIMS IS ALSO INLCUDED. IF NECESSARY, THE SHIMS CAN BE REMOVED ALTOGETHER TO CORRECT MISALIGNMENTS BETWEEN STRIKE AND LATCH. LOOSEN SCREW (A) APPROXIMATELY 2 ROTATIONS, SLIDE SCREW TO THE LEFT AND TIGHTEN. STRIKE COMMON CONTACT NORMALLY OPEN CONTACT (NO) NORMALLY CLOSED CONTACT (NC) MAXIMUM SWITCHING CURRENT - SCREW (B) SCREW (A) STEP 1 STRIKE MONITORED STRIKES CONTAIN TWO, INTERNALLY MOUNTED, SWITCHES: ONE IS ACTIVATED BY THE LATCH BOLT'S PENETRATION OF THE STRIKE AND THE OTHER INDICATES THE ENERGIZED LOCK/UNLOCKED STATUS OF THE SOLENOID. STRIKE FAIL-SECURE OPERATION ( AS SHIPPED) UNLOCKS WHEN ENERGIZED. IF POWER FAILS THE, STRIKE REMAIN IN LOCKED POSITION. CURRENT DRAW VOLTS AMPS 12 VDC .440 12 AC .163 24 DC .230 24 AC .084 16 DC .458 16 AC .228 STRIKE NOTES: Rev. K THE SPACER IS DESIGNED TO SIMPLIFY MORTISING ON WOOD DOOR APPLICATIONS SPACER ASSY OPTIONAL KIT P/N WDC7400 INSTALLATION INSTRUCTIONS ECN: 11970 Date: 07-25-12 Page 2 of 2 Appvd: BC Date: 07-26-12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : dolid\dolid (DOLID) Create Date : 2012:07:26 13:10:28-07:00 Modify Date : 2015:05:27 11:23:40-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:05:27 11:23:40-07:00 Creator Tool : SolidWorks 2011 SP5.0 (2011272) Document ID : uuid:a4659103-ed9c-4b0f-b2df-3c8b465a12ac Instance ID : uuid:7c37ada6-7427-48c2-89f1-ebb14ffc243f Format : application/pdf Title : 80-0180-309_K Creator : dolid\dolid (DOLID) Producer : SolidWorks PDF Publisher Page Mode : UseOutlines Page Count : 2EXIF Metadata provided by EXIF.tools