5800C2W / 5800C2WCN Convert to Wireless Module – Installation Instructions
GENERAL INFORMATION
The Honeywell 5800C2W Convert to Wireless Module (referred to as the
5800C2W, module, or 5800C2WCN in Canada) enables retrofitting
existing security systems by; converting their wired sensors to
Honeywell’s 5800 series wireless technology, and replacing the existing
control panel with a LYNX Touch or LYNX Plus series control.
The 5800C2W also works with residential VISTA control panels
equipped with a wireless RF receiver and keypad.
IMPORTANT: This product is NOT for use with fire / heat sensors.
SPECIFICATIONS
Dimensions Length 7.0 in (178mm)
Width 4.5 in. (114mm)
Depth 1.5 in. (38mm)
Mounting Hardware Double stick tape and screws included.
Operating
Temperature
+14 to +140°F (– 10 to +60°C)
Humidity 95% RH Max.
Transmission Range Up to 300ft. (91 meters)
Operating Voltage Supplied by plug-in transformer
15.5VDC (± 5%) @ 1A
P/N: 300-07052, or 300-07102 Canada
Battery Backup Use 12V, 4Ah battery such as Honeywell
467, Yuasa NP4-12, Casil CA1240 or
equivalent. Provides 4 hours of backup.
Battery is to be located in the existing
control panel.
DO NOT use batteries of larger capacity.
Tamper Detection Activated when the cover is removed.
5800C2W Supervision low battery
backup battery power
each enrolled zone transmits a supervi-
sory message every 72 minutes
AC loss is reported as low battery
(See LED descriptions on back page.)
LED Status Indicators input power
backup power
wireless trans-
mission
(The input power indicator is viewable
through the enclosure cover.)
Input Zones
(9 hardwired)
All zones that are used must have an EOL
resistor. (Refer to the back page for de-
tailed information.)
Auxiliary Output
(12VAUX)
Provides 14.2VDC ±15% @ 100mA to
supply PIR motion, or glassbreak sensors.
1 Mount and wire the module
Guidelines:
Since the existing control panel is being replaced, its security func-
tions will be performed by the new LYNX or VISTA control panel.
The existing control panel can remain for the purpose of housing the
backup battery. The existing control panel can be powered down
and the transformer unplugged.
The 5800C2W module will charge the battery. This is also a good
time to replace the existing battery if needed.
At the existing control panel, tag and remove the sensor wires as
they will now go to the 5800C2W. Up to nine [9] hardwired zones
can be handled by each 5800C2W module.
DO NOT mount inside the control panel or other metal enclosure.
The integral battery cable fuse MUST be positioned inside the control
panel enclosure. The fuse is not replaceable.
Before mounting permanently, conduct Go/No Go tests (see control’s
instructions) to verify adequate signal strength, relocate if necessary.
Mounting and Wiring:
Note: This product must be installed in accordance with
ANSI/NFPA 70, National Electrical Code.
1. Refer to the wiring diagram on the back.
2. Select a mounting position for the module. In most installations
locating the module close to the existing control panel is ideal.
Note: If needed, the 5800C2W can be located remotely by extend-
ing the existing sensor wires.
If needed, you may cut and splice (observing good workmanship)
the battery wires and extend their length up to 0.9 meters (3ft)
using 22 AWG wire, minimum. Ensure the integral battery cable
fuse is positioned inside the control panel enclosure.
3. Mount “Tamper Magnet” to enclosure cover.
4. Attach using the supplied double stick tape (and screws if desired).
5. Ensure the wiring is complete. Use cable ties as necessary to secure
wiring. Plug the power transformer into an un-switched outlet and
secure with screw. Then attach the backup battery wires.
2 Calibrate the module zones
Calibration: The calibration process enables the 5800C2W to learn
what zones will be active and what value EOL resistors are used.
Unused zones that are open WILL NOT be recognized and reported.
1. Ensure all zones are connected and not tripped.
2. On the 5800C2W, click the top left button (SW2). Indicator LED #1
will flash Red for 1/2 second, then turn steady Green.
3. DONE. The 5800C2W is calibrated and ready to enroll in the control
panel.
Note: If the 5800C2W loses both AC and battery backup power, the
zone calibration data is retained.
3 Enroll the module in the control panel
Enrollment: As a wireless device, each 5800C2W has a unique 7-digit
serial number to enable the control panel to recognize it. Further, since
the 5800C2W has nine zones each zone is automatically assigned the
next sequential serial number.
Remember, unused zones are not reported or transmitted to the control
panel. For example, below all zones except #6 are used:
Item Serial # Item Serial #
zone 1 xxx-xxx1 zone 6 (if not used) none
zone 2 xxx-xxx2 zone 7 xxx-xxx7
zone 3 xxx-xxx3 zone 8 xxx-xxx8
zone 4 xxx-xxx4 zone 9 xxx-xxx9
zone 5 xxx-xxx5
All zones are Loop 1.
The 5800C2W tamper switch is assigned as Loop 4 for the lowest
numbered zone used.
Enrolling the 5800C2W into the control panel is similar to any 5800
series wireless device. There are two methods that can be used.
Method 1:
1. Refer to the control panel’s guide and set it to “Zone Programming”
mode.
2. Enroll the first zone as an "RF" type (supervised RF) device in the
control panel.
3. Trip the zone (LED #1 flashes Green to indicate the information has
been sent) and wait for the keypad to beep (about 2 seconds), then
trip zone again. Confirm the correct serial number has been enrolled.
Repeat for each zone used.
Method 2:
1. Locate the unique 7-digit serial number for the 5800C2W module.
This is located on the carton and on the module’s circuit board.
2. For each zone used, increment (in order) the 7-digit serial number to
determine the serial number for each zone. Refer to the example
table to the left.
Note: The next step can also be done using Honeywell’s Compass
software.
3. Refer to the control panel’s guide and manually program the
5800C2W module, followed by each of its zones.
All zones are Loop 1.
The 5800C2W tamper switch is assigned Loop 4 for the lowest
numbered zone used.
PLEASE GO TO BOTTOM OF
THE NEXT PAGE FOR FCC / IC
AGENCY STATEMENTS.
LED Function Note: LEDs are shown as they appear on the circuit board.
#1 Red (blinking) – Module needs calibrating.
Green – Module is calibrated.
#2 Green – DC power (15.5VDC, ± 5%) from the plug-in transformer is present.
Red – DC power is NOT present.
(Viewable through the enclosure cover.)
#3 Yellow – Low battery or No battery.
When the battery voltage drops to 11.2VDC, a low battery message is sent to
the control panel and LED 3 turns yellow.
When the battery voltage drops to 10.0VDC, the battery is disconnected. The
battery will not connect again until AC is restored.
#4 Green (blinking) – RF signal transmission.
4
3
2
1
12
11
10
9
8
7
6
5
4
3
2
114
13
Z8
GND
Z7
Z6
GND
Z5
Z4
GND
Z3
Z2
GND
Z1
GND
Z9
GND GND
15.5V IN
5800C2W-001-V0
12VAUX
+
EOLR
RED
BLACK
SW1
SW2
-
+
Integral
Fuse
(+)
NOTES:
All zones that are used MUST have an EOL
resistor.
For a NC loop without an EOL resistor, you must add one in series with the loop.
If the existing installation zones have EOL
resistors (from 1k to 10k ohms) they may
remain.
For a NO loop without an EOL resistor, you must add one in parallel (across) the
loop. Preferably it should be located at the end of the loop furthest away from the
control panel.
EOL resistor values must be from 1k to 10k
ohms.
IMPORTANT: The first battery test occurs 1 hour after power up. To quickly verify a good backup battery, unplug and then plug back in the power
supply; the system will perform a battery test within 1 minute.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or
modifications could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions,
may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance
with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet
appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception
indésirable.
WARRANTY Go to: http://www.security.honeywell.com/hsc/resources/wa/
DOCUMENTATION AND ONLINE SUPPORT Go to: http://www.security.honeywell.com/hsc/resources/MyWebTech/
Ê800-15422}Š
800-15422 9/13 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright 2013 Honeywell International Inc.
www.honeywell.com/security
To backup battery
located in existing
control panel.
OBSERVE
POLARITY.
Not Used.
Zone Calibration button.
Provides 11.2VDC ±15% @ 100mA
to supply PIR motion, or glassbreak
sensors.
Zone 1 of 9
shown wired.
PLEASE GO TO THE BOTTOM
OF THIS PAGE FOR FCC / IC
AGENCY STATEMENTS.