Ademco 8DL5800RL Remote Security Tranceiver User Manual II with FCC label info
Honeywell International Inc. Remote Security Tranceiver II with FCC label info
Ademco >
Contents
- 1. II with FCC label info
- 2. II with FCC lable info
II with FCC label info
KDEMCD (Draft 7/13/00) K37eo 7/13/00 5800RL Wireless Relay Module INSTALLA TIOItI AND SETUP GUIDE INTRODUCTION The 5800RL Wireless Relay Module provides 2 form-C relays and operates in coniunction with either the LYNX' Selt- Contained Control/Communicator or with other control panels that support the 5383 Transceiver Module and 5800 series devices, The 5800RL emulates the functions of a SSOOTM with the SBOORL's relays activated via wireless signals from the LYNX/control. The 5800FtL includes an internal case tamper switch, and is powered from a 12VDC or 9VAC external power source. The SBOORL sends tamper and supervision transmissions using its built-in serial number. The 5800RL‘s serial number must be enrolled by the Lynx or the control and assigned to a zone. Refer to the Lynx‘ or the controls installation instmctions for details. arm newts 5mm ' COMPATIBILITV The 5500HL is compatible wrttl LYNX controls having software version 9.0 or higher. minus 5 1 Runs ARE wllvAlEb n xvaEu mNnmoNs "win AND sinew-aloft steam sENv ro eornaot Figure 1. Block Dlagram POWERING THE 5800RL The SBOORL can be powered from either an AC or DC external power source connected to terminals 7 and 8 (see Figure 2). Power source ratings are as follows: Power Sources TYPO Elli"! Ac svac. 15VA(e.g.,ADEMCO taaz) oc 12VDC, tOOmA First cut the connector all the unit's cable. then strip the wire ends and connect to lenninals 7 and 5. NOTE: Use of power sources with higher or lower voltages may result in damage or a failure to operate properly. RELAY and LED OPERATION The 5800RL provides two, dry contact, form-C relays (SPDT. rated 2A, 28VACNDC). When used with LYNX, each relay activates upon certain system conditions. The red and yellow LEDs, located above the DIP switch, monitor the relay activity as shown below: The RF interference LED monitors local radio frequency interference. If this LED is continuously lit, the SBOORL should be relocated. Relay and LED Functions Relayl LED Acnvmsupen... A Yellow Alarm conditions as follows: steady ON = burglary alarm (no contact connects to court temporal on = lire alarm (N0 connects temporal to com) on = no alarms active (No contact camera to COM) a Red Smem armed/disarrned as tollows' on = system armed away, stay. or instant (N0 contact connects to COM) OFF = system disarmed (NC Contact connects to COM) N/A Green Normally on when power IS applied Flickering indicates microcomputer activity. MOUNTING LOCATION GUIDELINES Use the following guidelines when selecting a mounting location for the 5BDORL Relay Module: c Mount the SBOORL in a high location for best wireless reception. 0 Do not mount the 5800RL on or near metal objects. This decreases range and/or blocks wireless transmissions. 0 The SBOORL must be located at least 10 feet from any remote keypads to avoid interlerence lrom the microprocessors in those units. WIRING AND MOUNTING IMPORTANT: Before permanently mounting the SBOORL, you must perform the setup procedure described in the Setting Up the SBDOHL section. 1. Remove the 5800RL's cover (insert the blade of a small screwdriver in the slot at the cover‘s top end and twist). 2. Disconnect any wiring already connected to the module. ANTENNA 2 ©$fi® l~NO lRELAV woman. ZWACNDCI 2-No lam“ a-cou tenc e-com 7-‘00RDCMIN auconoct—lm as INTERFERENCE LED (RED) nurse swirclt mi vi Figure 2. Connection Diagram 3. Hold the module in the desired mounting position and mam the mounting hole locations through the two mounting holes in the base oi the module. Screws and plastic anchors are suitable for a typical installation, but any two suitable Iasteners may be used that secure the base Iirmlyto the mounting sunace. Note: The external power supply unit should be mounted in close proximity to the 5800RL. This avoids voltage losses that occur on long power lines. 4. Connect relay and power wiring to the 5800RL‘s terminals. Refer Figure 2. 5. Place the front cover over the module, position the wiring in the exit slot. and snap the cover in place. The SBOORL module should now be tested with the rest of the system,
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2000:11:14 11:34:07 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2000:11:14 11:34:12-05:00 Page Count : 1EXIF Metadata provided by EXIF.tools