Ademco 8DL5800RL Remote Security Tranceiver User Manual II with FCC label info

Honeywell International Inc. Remote Security Tranceiver II with FCC label info

Contents

II with FCC label info

Download: Ademco 8DL5800RL Remote Security Tranceiver User Manual II with FCC label info
Mirror Download [FCC.gov]Ademco 8DL5800RL Remote Security Tranceiver User Manual II with FCC label info
Document ID127303
Application IDD+3GGIgWcLUFtRnhwfWWGg==
Document DescriptionII with FCC label info
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.19kB (202381 bits)
Date Submitted2000-12-01 00:00:00
Date Available2001-01-25 00:00:00
Creation Date2000-11-14 11:34:07
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2000-11-14 11:34:12
Document TitleII with FCC label info

KDEMCD
(Draft 7/13/00)
K37eo 7/13/00
5800RL
Wireless Relay Module
INSTALLA TIOItI AND SETUP GUIDE
INTRODUCTION
The 5800RL Wireless Relay Module provides 2 form-C relays
and operates in coniunction with either the LYNX' Selt-
Contained Control/Communicator or with other control panels
that support the 5383 Transceiver Module and 5800 series
devices, The 5800RL emulates the functions of a SSOOTM with
the SBOORL's relays activated via wireless signals from the
LYNX/control. The 5800FtL includes an internal case tamper
switch, and is powered from a 12VDC or 9VAC external power
source. The SBOORL sends tamper and supervision
transmissions using its built-in serial number. The 5800RL‘s
serial number must be enrolled by the Lynx or the control and
assigned to a zone. Refer to the Lynx‘ or the controls installation
instmctions for details.
arm
newts
5mm
' COMPATIBILITV
The 5500HL is
compatible wrttl LYNX
controls having software
version 9.0 or higher.
minus 5 1
Runs ARE
wllvAlEb n
xvaEu
mNnmoNs
"win AND
sinew-aloft
steam sENv
ro eornaot
Figure 1. Block Dlagram
POWERING THE 5800RL
The SBOORL can be powered from either an AC or DC external
power source connected to terminals 7 and 8 (see Figure 2).
Power source ratings are as follows:
Power Sources
TYPO Elli"!
Ac svac. 15VA(e.g.,ADEMCO taaz)
oc 12VDC, tOOmA
First cut the connector all the unit's cable. then strip the wire ends and
connect to lenninals 7 and 5.
NOTE: Use of power sources with higher or lower voltages may result in
damage or a failure to operate properly.
RELAY and LED OPERATION
The 5800RL provides two, dry contact, form-C relays (SPDT.
rated 2A, 28VACNDC). When used with LYNX, each relay
activates upon certain system conditions. The red and yellow
LEDs, located above the DIP switch, monitor the relay activity as
shown below: The RF interference LED monitors local radio
frequency interference. If this LED is continuously lit, the SBOORL
should be relocated.
Relay and LED Functions
Relayl LED Acnvmsupen...
A Yellow Alarm conditions as follows:
steady ON = burglary alarm
(no contact connects to court
temporal on = lire alarm (N0 connects temporal to com)
on = no alarms active
(No contact camera to COM)
a Red Smem armed/disarrned as tollows'
on = system armed away, stay. or instant
(N0 contact connects to COM)
OFF = system disarmed
(NC Contact connects to COM)
N/A Green Normally on when power IS applied Flickering indicates
microcomputer activity.
MOUNTING LOCATION GUIDELINES
Use the following guidelines when selecting a mounting location
for the 5BDORL Relay Module:
c Mount the SBOORL in a high location for best wireless
reception.
0 Do not mount the 5800RL on or near metal objects. This
decreases range and/or blocks wireless transmissions.
0 The SBOORL must be located at least 10 feet from any remote
keypads to avoid interlerence lrom the microprocessors in
those units.
WIRING AND MOUNTING
IMPORTANT: Before permanently mounting the SBOORL,
you must perform the setup procedure described in the
Setting Up the SBDOHL section.
1. Remove the 5800RL's cover (insert the blade of a small
screwdriver in the slot at the cover‘s top end and twist).
2. Disconnect any wiring already connected to the module.
ANTENNA 2
©$fi®
l~NO lRELAV woman. ZWACNDCI
2-No lam“
a-cou
tenc
e-com
7-‘00RDCMIN
auconoct—lm
as INTERFERENCE
LED (RED)
nurse
swirclt
mi vi
Figure 2. Connection Diagram
3. Hold the module in the desired mounting position and mam
the mounting hole locations through the two mounting holes
in the base oi the module.
Screws and plastic anchors are suitable for a typical
installation, but any two suitable Iasteners may be used that
secure the base Iirmlyto the mounting sunace.
Note: The external power supply unit should be mounted in
close proximity to the 5800RL. This avoids voltage losses that
occur on long power lines.
4. Connect relay and power wiring to the 5800RL‘s terminals.
Refer Figure 2.
5. Place the front cover over the module, position the wiring in
the exit slot. and snap the cover in place.
The SBOORL module should now be tested with the rest of the
system,

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2000:11:14 11:34:07
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2000:11:14 11:34:12-05:00
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CFS8DL5800RL

Navigation menu