Ademco 8DL5816OD Door/Gate Security Transmitter User Manual manual

Honeywell International Inc. Door/Gate Security Transmitter manual

manual

 5816OD Wireless Outdoor Sensor – Quick Installation Guide For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/    General Information and Component Identification The Honeywell 5816OD Wireless Outdoor Sensor (referred to as the sensor) brings the convenience of wireless technology to the outdoors.  The major features are:  Weatherized security protection for an outdoor environment.  Great for sheds, barns, garages, pool gates, fences, and rural mailbox (notifications).  Versatile mounting options on flat and round materials.  Cover and rear tamper detection.  Can be painted to coordinate with mounting surface.  Operating temp: – 40 to + 50° C (– 40 to +122° F) at  RH of 100% (rain, snow).  Magnet Gap (Wood): 2 inches  Magnet Gap (Metal): 1.75 inches /no Magnet Spacer  Magnet Gap (Metal): 2 inches /with Magnet Spacer COMPONENT IDENTIFICATION 5816OD-001-V0SENSORMOUNTINGPLATE MAGNETMAGNETSPACERSENSORBATTERYCHAMBERCOVER   Installing / Replacing the Batteries IMPORTANT:  Change both batteries at the same time.  Do not mix weak batteries with new batteries.  Use two (2) lithium 1.5VDC AA cells.  (For best life, use Eveready's Energizer Ultimate LITHIUM  AA batteries, Honeywell part number 462)  OBSERVE BATTERY POLARITY. Battery Replacement: 1.  Remove cover screw and swing Sensor to remove from Sensor Mounting Plate. 2.  Use screwdriver in any pivot point and pry Battery Chamber Cover off.  Replace batteries. 3.  Orient Battery Chamber Cover so the screw hole lines up with the screw hole in the sensor cover, and press to close. 4.  Engage Sensor tabs into mating holes in Sensor Mounting Plate and swing closed.  Secure with cover screw.  5816OD-002-V0++PRYPOINTSTERMINAL BLOCKFOR EXTERNALCONTACT SWITCH  Mounting Guidelines  Mount the Magnet on the magnet sensing side of the Sensor as indicated by the ribs on the Sensor.  Mount Sensor on stationary surface, and Magnet on moveable surface.   When used on wooden sheds and barns, mount the sensor and magnet on the inside of the structure.  Use the Magnet Spacer when mounting on metal surfaces; or if needed to achieve proper alignment with Sensor. Flat Surfaces:  Use screws suitable for the material being fastened to.  FLAT SURFACES COVERSCREW MOUNTINGSCREW (4) 5816OD-003-V0MAGNET MAGNETSPACERMOUNTINGSCREW (2) SENSOR SENSORMOUNTINGPLATEFENCEPOSTFENCE GATE AGENCY STATEMENTS ARE AT THE BOTTOM OF PAGE 2
Curved Surfaces:  Mount using self locking stainless steel strap ties.    5816OD-005-V0 Self Locking Stainless Steel Strap Tie  Alternately you can use extra heavy duty Nylon 6/6 UV and Temperature Rated cable ties  (0.5 inch wide).  If desired you may use screws in addition to the ties. CURVED SURFACES 5816OD-004-V0MAGNETSENSOR GATEPOSTGATEMAGNETSENSINGSLIDECOVERSCREW FENCEMAGNETSPACERSENSORMOUNTINGPLATE ROUTING EXTERNAL WIRING (Optional for use with external closed contact switches): Note: Use minimum of 22AWG jacketed cable.  The contact switch must be a normally closed type. UL – The wired contact must be less than 3 feet from the transmitter. 1. Strip cable jacket back 4-inches to allow enough slack to remove Battery Chamber Cover when changing batteries. 2. Pass cable through the access hole in Sensor Mounting Plate.  Use cable notch on mounting plate to pass jacketed portion of cable through.  Then attach the Sensor Mounting Plate.  3. Route cable to the external contact switch and fasten at intervals to secure cable. 4. Remove the Battery Chamber Cover and thread wires through the rubber wire seal. 5. Connect wires to terminal block in battery chamber, and replace Battery Chamber Cover.  (Note, orient the  cover so the screw hole lines up with the screw hole in the sensor cover, and press to close.) 6. Engage Sensor tabs into Sensor Mounting Plate mating holes and swing closed.  Secure with cover screw.  SENSOR SENSORMOUNTINGPLATEBATTERYCHAMBERCOVER5816OD-006-V0TO EXTERNALCONTACT SWITCHCONNECT WIRESTO TERMINAL BLOCKIN BATTERY CHAMBER PAINTING THE SENSOR: The sensor and magnet may be painted to coordinate its color with the mounting surface.  Use only paints that are made for plastic and follow the manufacturers directions for preparing the plastic and applying the paint.  Note, the required drying and curing times. DO NOT USE METALLIC PAINT COLORS. Recommended Paints:  Krylon®  "Fusion for Plastic"  Rust-Oleum® "Plastic"  Dupli-Color® "Vinyl & Fabric Coating"  Programming the Control Panel You must program the transmitter's serial number, input type (RF Supervised), response type, and loop # in the control panel.  (Either or both loops may be used.  Loop # 2 is for the magnet sensing, and Loop # 1 is for the external contact switch.)  Refer to the control panel’s instructions for further details.  Note: The transmitter's serial number may be found on the carton, and in the Battery Chamber.  FCC/IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference  that may cause undesired operation. FCC STATEMENT The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.     WARRANTY For the latest warranty information go to: http://www.security.honeywell.com/hsc/resources/wa/ Ê800-04494UŠ 800-04494  11/09  Rev. A  2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY  11747  Copyright  2009 Honeywell International Inc. www.honeywell.com/security

Navigation menu