Ademco 8DL5817CB-1 Security Remote Transmitter User Manual Full page fax print
Honeywell International Inc. Security Remote Transmitter Full page fax print
Ademco >
II with part 15 statment and fcc id
ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of meay Corporation, and us divisions, subsidiaries and affillales ("Seller“), 165 Eileen Way, Sycssel, New York 1179]. warrants its products io be in conformance wilh its own plans and specifications and to be free from defects in malol'inls and workmanship under normal use and service for 18 months from lhe dale smp control on the product or, for products not having an Adcmco date stamp, for 12 months from dale of original purchase unless Ihe installation inslruclions m' catalog sols forth a shoner per-rod. in which case the shorter period shall apply Sellers obligzuoil shill] be hmiled to repairing or replacing, at its option, free ofcharge for materials or labor, any product which is proved not in compliance with Seller's specifications or proves defective in materials or workmanshlp under numlltl use and service. Seller shall have no obligalion undcr this limited Warranty or otherwise if the product is altered or improperly repaired or San/iced by anyone oincr than Adcmco factory service. For warranty service, ietum product tiansponarion prepaid, to Ademco Factory Service, 165 Eileen way, Syosser, New York l 1791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the producls it sells my not be compromised or eiicnmvented; lhal the products will prevent any personal injury or property loss by burglary. robbery, fire or mhcrwlsc; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the fish of a burglary, robbery. fire or other events occuning without providing an alarm, bill it is not insurance or a guamnlee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY. SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY 1035 OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE. REGARDLESS OF CAUSE OR ORIGIN, SELLER‘S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only wammy made by Seller on this product. No increase or alteration. wnllen or verbal. of the obligations of this Limited Warranty is aurhoriued. FCC NOTICE FCC ID: ('l-‘hhl)l.§Xl7('I-H This device eornplias with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This devioe may not cause harmful iuterferenoa, (2) This device must accept any interference received, including interference that may cause undesired operation. I(':573I'15x|7('BI ADEMGD Honeywell luternational Inc. 155 Eileen way, Syossel, New York 11791 I|||IIII|II|IIlI|II||II|I K5623 8/00 aADEMCO Ksszs woo 5817CB WIRELESS COMMERCIAL TRANSMITTER INSTALLATION INSTRUCTIONS GENERAL INFORMATION The 581708 Wireless Commercial Transmitter is a dour- or window»mounted burglary transmitter. Upon activation, it emits an RF signal lo a control panel that, in turn, sends a burglary or fire alarm to the oentral station. The 551708 has three unique input loops (zones). The first loop (primary loop) is supervised and typically used for high~priority alarm reporting such as fire. It requires to 470K ohm end-of-line resistor to be placed across the sensor. The second loop is the built—In normally closed reed switch (used in conjunction with a magnet, as described below). The third loop is another normally closed burg loop. All three loops may be used. A fourth (automatically enrolled) loop wntains two tamper switches to protect the 6817CB transmitter. A built— in cover tamper switch is activated when the cover is removed. A unit tamper switch is activated if the unit is separated from its mounting plate. The 581705 has its own unique serial number permanently assigned during manufacture. A control panel is required to "enroll" this transmitter serial number at some point prior in its usage in the alarm system. Refer to the control panel's installation instructions for further details. For UL installations. a sensor and its wiring may not be more than 3 feet from the transmitter. Note: During prograrruning or the control panel, 5817CB transmitters are treated as “RF" (i.e., supervised RF) Type (mandatory for UL installations). Mounilng For proper orientation of the unit in relation to its wall mounting plate and the loop wiring, rend oil of this section befom installing tho unit. Befom mounting the tmnsmiltzr permanently, conduct Go/No Go tests (see contml's instructions) to verify adequate signal strength and reorient or relocate the transmitter if necessary. When o satisfactory location is found, remove the battery and proceed with installation The following mounting instructions assume that the unit will be mounted as shown in the diagrams. The unit may, however, be installed in any direction, as long as the relationship ofthe unit baits mounting plate is maintained. The mounting plate, installed as described below, enables easy removal of the unit for servicing, should it become necessary. 1. 2. Remove the transmitter’n cover by inserting the flat blade of a small screwdriver into the pry—off slot at the bottom end of the unit on the right side closest to the cover's decorative ribs and twisting. Dlsengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the mounting plate release hole (see Diagram 2) and pushing the locking tab out (see Diagram 1). Slide the mounting plate downward along the case back. Note: For this application, the alignment guide strip along one edge of the mounting plate serves no function and may be broken away, if desired. if concealed wiring is to be used, feed the wires through the concealed wiring entry hole at one oorner of the plate (surface wiring is mentioned in Step 5 below), Install the mounting plate, with its case-holding posts pointing up, in the location selected, as described in the control unit's installation instructions. Use the two flat-head screws supplied. If surface wiring is to be used, remove the knockout slot in the case hack (located across from loop 3 terminal block), Surfiwe wiring should enter through this lmuclrcd out space provided. Do not connect the wiring to the terminal hlockls) yet.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 1 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e914769f-77b1-4e9a-8824-b27a230208e0 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2005:10:06 16:48:46-04:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2005:10:06 16:49:32-04:00 Metadata Date : 2005:10:06 16:49:32-04:00 Document ID : uuid:de4f3db0-6f19-4aab-a9b7-c05a59c928d8 Format : application/pdf Title : Full page fax print Creator : E650365 Author : E650365EXIF Metadata provided by EXIF.tools