Ademco 8DL6152RF Keypad Transceiver User Manual

Honeywell International Inc. Keypad Transceiver 800 11537 A 6152RF ig 04 12 13

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

Users Manual

   ADEMCO 6152RF Keypad / Transceiver  –  Installation and Setup GuideFixed Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates normally-open relay output with the functions of a medium 16 zone RF Receiver and a 5800 Transmitter module. = READY to Arm= NOT READY to Arm= System ARMED= System NOT ARMEDProgrammable Function KeysArming Keys6152RF: Fixed Word Display2-Digit Zone IdentifierThe ‘21’ digits are used for specific trouble indications. Refer to the control panel instructions for details.  ALARMFIREAWAYBYPASSSTAYCHECK    INSTANT CANCELEDNO NIGHT ACNOT READYCHIME BATTESTPHONE6152RF-KEYPAD-LBLD-032613Sounder         WallSurface21SEE Detail AOptional Front Cover Securing Screw(Required in European Installations)Install Four (4)Mounting ScrewsControl Panel1. OPENKeypad Front Cover 2. WIRE 3. MOUNT•  Connect only one wire per terminal.  •  For Daisy-Chain Configurations, use    wire splicing so only one wire is     connected to each terminal.Mount on drywall, or in a single or double-gang electrical box.AUXRELAY OUTPUTCONNECTIONS[  ] GROUND[Y] DATA IN[+] +12VDC IN[G] DATA  O U TYellowBlackRedGreenCONTROL PANELTERMINAL STRIP16-24 AWG OnlyKEYPADNOCDATAINDATAOUTAUXDetail AGYTo activate Function keys, press and hold key for at least 2 seconds; key pairs are activated immediately.  Table 1 – Programmable                   Function Keys A or   and   B or   and   C or   and   D    Note:  See the control’s instructions for details on programming the Function keys for panic alarms or other special functions (i.e., macros). Programmable to support the following : - Bi-directional 5828/5828V wireless keypads and wireless keys (e.g., 5804BDV, 5834-4, etc.) -  Up to eight button-type wireless keys locally (programmed directly into the keypad), without occupying control panel zones -  Up to 16 5800 series wireless zones programmed into any supported control panel - Wireless keys with high security mode enabled Table 3 – Icon DescriptionsICON DESCRIPTIONTEST SYSTEMBYPASS ZONESASSIGN CODESCHIME MODEARM MAXIMUMARM INSTANTARM AWAYARM NIGHT STAYDISARMARM STAYSETTINGS Table 2 – Settings KeySettings KeyResultPress   for 2 Seconds  Enters Display Test Mode Press   for 2 Seconds and during the Display Test, press and hold   and  for 3 Seconds Reboots the Keypad (the keypad beeps and the ARM and READY LED’s flash for several seconds)  PLEASE GO TO PAGE 7  FOR THE AGENCY STATEMENTS
  - 2 -INSTALLATION AND APPLICATION GUIDELINES For installation, consider the following: •  Locate the 6152RF in an area and at a height convenient for user operation. • The 6152RF must be at least 10 feet from the control panel to ensure proper RF receiver operation. • Local wireless keys (wireless keys programmed directly into the 6152RF) may be used regardless of whether the RF receiver in the 6152RF is enabled or disabled. • If using bi-directional devices, be sure to enable the transmitter module in the 6152RF (program address 7).  •  If transmitters are programmed into the control panel, be sure to enable the receiver (program address 6). (Do not exceed the number of receivers supported by the control panel.) •  If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be entered into the 6152RF. This user code must also be programmed into the control panel. • You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID Source is the 6152RF (Local).Partition Installation Example  An example of an installation using two 6152RF Keypad / Transceivers with 2-Way Wireless Devices (e.g., 5828V) on two Partitions is shown below:   6152RFPartition #1System House ID = 16152RFPartition #2Local House ID = 25828 or 5804BDPartition #1House ID = 15828 or 5804BDPartition #2House ID = 2CONTROLPANELPartition #1 Partition #2      Table 4 – Partition Installation Settings 6152RF #1  6152RF #2 Keypad:  Must be assigned to Partition 1 in the control panel Must be assigned to Partition 2 in the control panel House ID:  Match Partition 1 House ID in the control panel and House ID in Wireless Device Match House ID in Wireless Device House ID Source: System  Local Receiver Enable: On  Off Transmitter Enable: On  On 4.  PROGRAM To program the keypad, first enter the Programming Mode, select a programming address and set the programming options.  Refer to the tables below and on the following pages for details on entering Programming mode, default values and programming choices for each option.   Table 5 – Programming Mode Action Result DisplayNotes 1. Enter Program Mode Within 30 seconds of power up or reboot, press and hold down the   and   keys at the same time for 3 seconds.    Note: Refer to Table 2 to reboot the keypad. Enters the Program mode at the Start screen and the keypad beeps three (3) times  oo, - - flash alternately [If any other numbers or letters appear press .) - The keypad will not enter programming mode if the panel is armed. - Press the   and   keys 60 seconds or more after power up to enter the User mode. This mode allows individual local wireless keys to be enabled and disabled (useful if, e.g., a user accidentally loses a wireless key).  Refer to the User Guide for instructions. -  To enter keypad Programming mode after power up period, reboot the keypad (see Table 2 on page 1) and try again after the keypad LED’s stop flashing.  -  The keypad automatically exits the Program mode if no keys are pressed for 90 seconds. 2. Enter a Programming Address  (See Program Address column in Table 6) Screen displays selected programming address See Display column in Table 6. -  (For example, enter [1] to go to Keypad Address; enter [2] to go to Receiver Address). 3. Set programming options Use the number and navigation keys to set the programming options. Refer to Choices column in Table 6.  - Press   to erase the current information and move back. - Press  to store the displayed information, the keypad beeps twice and the screen returns to Start
Download:
Mirror Download [FCC.gov]
Document ID1960842
Application IDpYeEmz5+UJKZe662fA6vNg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize278.32kB (3479047 bits)
Date Submitted2013-05-09 00:00:00
Date Available2013-11-05 00:00:00
Creation Date2013-04-12 13:25:00
Producing SoftwareAcrobat Distiller 9.5.2 (Windows)
Document Lastmod2013-04-29 11:36:05
Document TitleMicrosoft Word - 800-11537-A_6152RF-ig_04-12-13
Document CreatorPScript5.dll Version 5.2.2
Document Author: E727032
FCC ID Filing: CFS8DL6152RF

Navigation menu