Ademco 8DL6162RF Keypad Transceiver User Manual 800 11508 A 6162RF ig 04 03 13
Honeywell International Inc. Keypad Transceiver 800 11508 A 6162RF ig 04 03 13
Ademco >
Users Manual
GO TO PAGE 4 FOR FCC / IC INFORMATION ADEMCO 6162RF Keypad / Transceiver – Installation and Setup Guide Alphanumeric Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates functions of a High RF Receiver and a 5800 Transmitter module. 6162: 4-Line Alpha Display Custom Zone Designators • Supports wireless key transmitters (e.g., 5834-4) and bi-directional transmitters (e.g.; 5804BD, 5828/5828V). • Supports wireless keys with highsecurity (encryption) capability (e.g.; 5834-4). • Provides a nominal range of 200 feet for RF transmitters (some transmitters have a shorter range). • Supports RF jam detection. = System ARMED = System NOT ARMED = READY to Arm = NOT READY to Arm Arming Keys Sounder Table 3 – Icon Descriptions To activate Function keys, press and hold key for at least 2 seconds; key pairs are activated immediately. 6162rf-KEYPAD-LBLD-V0-032713 Table 1 – Programmable Function Keys A or and B or and C or and Programmable Function Keys Table 2 – Settings Key Settings Key Press Result Displays Settings Menu*: 1 Set Time/Date 2 View Event Log 3 Reboot Keypad 4 Set User Code** Note: See the control's instructions for details on programming the Function keys for panic alarms or other special functions (i.e., macros). 1. OPEN Follow instructions in the User Guide for these options; selecting option 3 reboots the 6162 keypad. ** Set User Code option available only with the following Control Panels: VISTA-10P Rev 4.16, VISTA-15P Rev 9.16, VISTA20P Rev 9.16 and VISTA-21iP Rev 3.16. Control Panel Control Panel Terminal Strip AUX AUX DATA DATA IN OUT Black (Gnd) Red (+12vdc) Green (Data To Control) Yellow (Data From Control) 2. WIRE • Connect only one wire per terminal. • For Daisy-Chain Configurations, use wire splicing so only one wire is connected to each terminal. ICON DESCRIPTION SETTINGS ARM AWAY ARM STAY ARM NIGHT STAY DISARM ARM MAXIMUM TEST SYSTEM BYPASS ZONES ARM INSTANT ASSIGN CODES CHIME MODE Wall Surface To Control Panel Terminal Strip 3. MOUNT Install Four (4) Mounting Screws • Mount on drywall, or in a single or double-gang electrical box. Optional Front Cover Securing Screw (Required in European Installations) 6162RF-installation-3-21-13 Keypad Front Cover APPLICATION GUIDELINES FOR THE 6162RF Table 4 – Application Guidelines If… This is the only transceiver on the system, And… You want to use both the receiver and transmitter function on a single-partition system, Then… • Set the keypad to a device address assigned to the desired partition.* • Enable the receiver. • Program a system House ID in the control panel (this will enable the transmitter function).** • Set the wireless devices that will communicate with this 6162RF to the same system House ID. There is another receiver or transceiver on the system, You want to use only the transmitter function on a second partition, • Set the keypad to a device address assigned to the desired partition.* • Disable the receiver. • Program a DIFFERENT House ID in the 6162RF than is programmed in the control panel.*/ ** • Set the wireless devices that will communicate with this 6162RF to the same House ID as the 6162RF. You want to use only the transmitter function on a singlepartition system, • Set the keypad to a device address assigned to the Partition 1. • Disable the receiver. • Program a House ID in the 6162RF that matches the system House ID programmed in the control panel.* • Set the wireless devices that will communicate with this 6162RF to the same House ID. Notes: * On VISTA-40 panels and above, wireless keypads (e.g., 5828) can only be used on a single partition. This partition is programmed in field 1*48, and must match the partition assigned to the 6162RF. Wireless keys can be used on more than one partition, using a House ID programmed in the 6162RF and the devices. In this case, the wireless keys must be assigned to the same partition as the 6162RF. ** On VISTA-20P panels, the 6162RF will use the House ID programmed in the panel for the partition to which it is assigned. Wireless keypads can only be used on Partition 1. 4. PROGRAM Refer to the following procedure to program the 6162RF: Table 5 – 6162RF Programming STEP 1. 2. DESCRIPTION Enter Programming Mode: Within 60 seconds of power up, press and hold down the same time for 3 seconds. Keypad Address. The keypad address appears (Default = 16). Enter a two-digit keypad address. Press the key to continue. 4. and CHOICES keys at the CON ADDR = 16 00-31 Receiver Enable. Enter [1] to enable, or [0] to disable the receiver. Press to continue. RECEIVER 1 = ON ON [0= OFF] 0 = OFF Receiver Address. If the receiver is enabled, enter the two-digit receiver address. (00-30). REC ADDR = 00 00-30 USER CODE : **** 0000-9999 Notes: – 3. DISPLAY Refer to the control panel’s installation instructions for the acceptable keypad addresses. Note: Refer to the control panel’s installation instructions for the acceptable receiver addresses. Press 5. to continue. User Code. Enter a valid four-digit user code to enable single button arming keys. The user code must be programmed in the control. Press to continue. -2- Table 5 – 6162RF Programming (continued) STEP DESCRIPTION 6. DISPLAY House ID. This prompt will only appear if the receiver is disabled. If the receiver is enabled the 6162RF will use the House ID programmed in the panel. Refer to Application Guidelines section when selecting a House ID. To program a House ID: Enter 01-31 To disable the transmitter: Enter 00 HOUSE ID = XX CHOICES 01-31 00 = Disable Transmitter Note: Each device that will receive status from the 6162RF must be set to the same House ID as the 6162RF (refer to Application Guidelines section). Press 7. to continue. Enable High Security Mode. Enter [1] to select High Security Mode. Note: If the High Security mode is enabled, the 6162RF will only recognize encrypted devices. If the High Security mode is disabled, the 6162RF will process commands from both encrypted and non-encrypted devices. Press 8. HIGH SECURITY OFF [1 = ON] 1 = ON (Enable) 0 = OFF (Disable) to continue. Disable High Security Devices. Press the prompt and exit Program Mode. key to skip this DISABLE HS DEV? NO [1 = YES] 1 = YES 0 = NO ACTIVATING HIGH SECURITY DEVICES The procedure below should be followed when using High-Security (encrypted) devices. Table 6 – Activating High Security Devices STEP DESCRIPTION 1. Follow the normal procedure for programming the device into the control panel (refer to the Installation Instructions for the device that you are programming). Exit out of Programming Mode. 2. Put the control panel in Go / No Go Test mode. (See the Installation Guide for the panel being installed.) 3. Follow the instructions supplied with each wireless device to enroll the device in High-security mode. After each device is enrolled, the 6162RF will momentarily display “SECURITY DEVICE” along with the device number and its serial number. Note: The 6162RF will support a maximum of 8 devices. If you attempt to enroll additional devices the keypad will display “EXCEEDED NUMBER” “ALLOWED DEVICES”. CHANGING USER CODE AND DISABLING HIGH SECURITY DEVICES This mode gives you the ability to change the user code used to enable the single button arming keys and disable high security on all wireless keys that have been enrolled in the 6162RF. The disable high security devices option is particularly useful if a user loses a wireless key. Once high-security (encrypted) devices have been disabled, they will only operate if the 6162RF is set to listen to both encrypted and non-encrypted devices (programming step 6 in Table 5). To completely disable the devices, they must be deleted from the control panel. Table 7 – Disabling High Security Devices STEP DESCRIPTION 1. After the keypad has been powered for at least 60 seconds, press and hold down the and keys at the same time for 3 seconds. The current keypad address will be displayed. (You cannot change the keypad’s address at this point.) Press to continue. DISPLAY CON ADDRESS=XX CHOICES Programmed Keypad address appears 2. User Code. At the User Code prompt, enter the valid 4-digit user code that will be used to enable the single button arming keys.. Press to continue. USER CODE : **** 0000-9999 2. Delete High Security Devices. Enter [1] to remove all high-security to continue. (encrypted) devices. Press DELETE DEVICES? NO [1 = YES] 1 = YES If YES was selected in Step 2 the unit will display a confirm request to delete the stored high security device. Enter [1] to accept and press to exit the programming mode. ARE YOU SURE? NO [1 = YES] 1 = YES 3. -3- 0 = NO 0 = NO TROUBLESHOOTING The error messages listed in the following table cause the 6162RF to produce a single ding tone. The table describes the error messages and the corrective actions. Table 8 – Troubleshooting Display Probable Cause Open Ckt Check 100 RF Receiver Check 8xx* No data is being received from the control panel. 1. The control panel does not see the 6162RF Receiver, or the Receiver is not functioning. 2. Another device on the keypad terminals is conflicting with this receiver address. Corrective Action Verify that the Yellow keypad wire is connected properly. 1a.Verify that the Yellow and Green keypad wires are connected properly. 1b.Verify that the receiver address is set for 00. 2. Verify the address of all devices on the keypad bus. *xx= the device address of the receiver. SPECIFICATIONS Physical: Displays: Sounder: Voltage: Current: NFPA-72: 4.88"H x 6.934"W x 1.02"D 4 x 16 alpha-numeric supertwist LCD, backlit. Speaker [fire alarm is loud, pulsing single tone; (all Keypads) burglary alarm is loud, continuous, dual tone]. 12VDC (power-limited) 210mA (ARMED LED lit, LCD backlight and sounder on), reduces to 120mA when panel is operating in standby mode (backlight off). Compliant. FEDERAL COMMUNICATIONS COMMISSION STATEMENT: The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT: This device complies with Part 15 of the FCC Rules, and RSS 210 of Industry Canada (IC). Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une reception indésirable. REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. WARRANTY INFORMATION: For the latest warranty information, please go to www.honeywell.com/security/hsc/resources/wa DOCUMENTATION AND ONLINE SUPPORT: For the latest documentation and online support information, please go to: http://www.security.honeywell.com/hsc/resources/MyWebTech 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2013 Honeywell International Inc. www.honeywell.com/security Ê800-11508+Š 800-11508 4/13 Rev. A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : E727032 Create Date : 2013:04:04 00:07:07-07:00 Modify Date : 2013:04:25 10:14:50-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.5.2 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:04:25 10:14:50-04:00 Format : application/pdf Title : Microsoft Word - 800-11508-A_6162RF-ig_04-03-13 Creator : E727032 Document ID : uuid:c5dd0ab4-7341-42ed-9104-88f4d124a191 Instance ID : uuid:59ce4be9-227b-4307-afa3-f8643e7af7a2 Page Count : 4EXIF Metadata provided by EXIF.tools