Ademco 8DLCOMR6 Wireless Smoke and CO Detector User Manual

Honeywell International Inc. Wireless Smoke and CO Detector Users Manual

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

Users Manual

   SiXCOMBO  Combination Smoke/Carbon Monoxide (CO) Detector / Combinación de detector de Humo/Monóxido de carbono (CO) Quick Installation Guide Guía Rápida de Instalación  This device is intended for use with Honeywell controls that support SiX series devices including the SiXCOMBO. Check the control for compatibility with this device. This device occupies 3 control panel zones, one zone for each service (smoke detection, heat detection, carbon monoxide detection).  FEATURES •  Multi-Criteria Sensing: uses four sensing elements to react faster while minimizing false alarms:   - Photoelectric smoke sensor detects airborne smoke particles   - Carbon Monoxide (CO) sensor detects smoldering fires   - Infrared (IR) sensor measures ambient light and flame signatures, such as flame flicker   - Thermal detection monitors for dangerous rise in temperature •  CO Detector End-of-Life reporting (detector needs replacing) •  Smoke detector maintenance reporting (detector needs cleaning or replacing) •  Low Battery Detection •  One Go / All Go: all smoke/CO detectors in the system programmed as one-go-all-go will sound on alarm. •  Voice announcements (English only)  See Installation Instructions (800-22142 – https://mywebtech.honeywell.com/) and the Limitations of Fire Alarm Systems Insert (800-15144 12/15) and System Smoke Detectors Application Guide (SPAG9101 7/12).  LED INDICATORS The SiXCOMBO Smoke/CO detector has a multi-color top LED:   Green =  Supervisory indication; blinks during power on, reset, and during normal operation Amber =  Signal maintenance and trouble events Red =   Alarm condition (either Smoke or CO) Side LED windows indicate alarms:  Red = smoke alarm Blue = CO alarm           Este producto está diseñado para ser usado en controladores Honeywell que soportan dispositivos de la serie SiX including the SiXCOMBO. Check the control for compatibility with this device. This device occupies 3 control panel zones, one zone for each service (smoke detection, heat detection, carbon monoxide detection).   CARACTERISTICAS  •  Detección multi-criterio: Utiliza cuatro elementos de detección para una más rápida reacción mientras se minimizan falsas alarmas:   - Sensores fotoeléctricos de humo que detectan partículas de humo en el aire   - Sensores de detección de Monóxido de Carbono (CO) para detección de incendios sin llama   - Sensores infrarrojos (IR) que detectan luces de ambiente y señales de flamas tales como movimiento de las llamas   - Detección termal que monitorea aumento peligroso de temperaturas • Fin de vida útil del detector de CO (el detector necesita ser remplazado) • Reporte de mantenimiento del sensor de humo (Cuando el sensor requiere limpieza or replacing) •  Detección de batería baja. •  Uno se activa / Todos se activan: todos los detectores de humo/CO en el sistema programados como “uno se activa/todos se activan”, sonarán su propia alarma •  Voice announcements (English only)  Vea la guía de instalación de Honeywell (800-22142- https://mywebtech.honeywell.com/) y el inserto de las limitaciones de sistemas de alarma de fuego. (800-15144SP 12/15). Consulte la Guía de aplicación de detectores de humo del sistema (SPAG9101 7/12).  INDICADORES DE LED El detector de humo/Monóxido de carbono SiXCOMBO contiene un LED multicolor:  Verde = Indicador de supervisión; parpadea durante iniciación, reinicio y durante operación normal. Ámbar = Señal de eventos de mantenimiento o problemas Rojo = Condición de alarma (de humo o monóxido de carbono) Ventanas de LED laterales: Rojo = Humo, Azul = Monóxido de carbon  ENROLLMENT REGISTRO  IMPORTANT NOTES:  • The Smoke, Heat, and Carbon Monoxide (CO) sensors each have unique MAC ID numbers (serial numbers) that are enrolled in separate zones. • Once enrolled, the device cannot be used with another system until it is removed from the current controller. See the 24-hour Enrollment Deletion section below or the controller’s instructions.  Enroll the Device Services (Smoke, Heat, CO) 1. Remove the detector from the base plate (tamper switch must be faulted when enrolling). 2. Put the control panel in Zone Programming mode.  For Lyric Controller: Security > installer code > Program > (scroll down) > SiX Programming 3. Pull the battery tab to activate enrollment process (be sure batteries are seated properly to avoid a false low battery condition). If the battery tab has already been removed and the unit is powered up, press either Test switch for less than 3 seconds to activate the enrollment process. 4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the green LED lights steady for 3 seconds and the device announces successful enrollment.   If the LED does not light steady, enrollment failed. Retry by pressing either Test switch for less than 3 seconds.   All services (Smoke, Heat, and CO) are automatically enrolled in sequential (or next available) zone numbers with the following default attributes: Zone Device Type Zone Response Type Smoke Det. Smoke Detector Fire No Verification Heat Det. Heat Sensor Fire No Verification CO Det. Carbon Mono. Det. Carbon Monoxide   NOTE: Maintenance and CO End-of-Life are automatically enrolled for the respective smoke and CO zones. Upon either of these conditions, Contact ID code E386 “Low Maintenance Smoke” is sent for the respective zone.  Supervision: Detector supervision is factory set for 1 minute and is not programmable.  5. To assign zone descriptors for each of the zones and/or change device type or zone response type, select the zone then select Edit and make the desired changes. Press Save when done.  24-Hour Enrollment Deletion Use this procedure within 24 hours of initial enrollment to delete this device from the controller. This allows reenrollment in a specific controller in case enrollment in that controller failed (i.e., the device inadvertently enrolled in a different controller). This resets the device to factory default settings and removes the communication link data in the controller in which it is enrolled, allowing the device to be reenrolled in the desired controller. 1.  Press and hold both the Smoke and CO test switches simultaneously for 5 seconds, then release. The green light flashes rapidly.  2. Press and hold both buttons again for one second and release.     OPEN / ABIERTO  Operation Modes / Modos de operación MODE /  MODO Status LED (Top) / Estado del LED LED Windows (Side) / Ventana del LED (Lateral) Sounder / Sonador Speaker / Bocina Power Up / Encendido Blink Green, every  2 secs/ Parpadea verde cada  2 segundos Dark / Apagado Silent / Silencio Voice welcome, instructions after first time power-up or after default / Bienvenida de voz, seguido por las instrucciones POR para la selección de lenguaje, enrolamiento, pruebas Normal (Standby) / Estado normal Single Blink Green  every 10 sec / parpadeo verde cada 10 segundos Dark / Apagado Silent / Silencio Silent / Silencio Smoke Alarm / Alarma de humo Blink Red every 10 secs / parpadeo rojo cada 10 segundos Blink Red / Parpadeo rojo Temp-3  “Warning, smoke, evacuate”/ “Advertencia, humo, evacuar”  Thermal Alarm / Alarma termal Blink Red every 10    secs / parpadeo rojo cada 10 segundos Blink Red / Parpadeo rojo Temp-3 “Warning, smoke, evacuate”/ “Advertencia, humo, evacuar” CO Alarm / Alarma de monóxido de carbono Blink Red every 10    secs / parpadeo rojo cada 10 segundos Blink Blue / Parpadeo azul Temp-4 “Warning, carbón monoxide, move to fresh air” / Advertencia, monóxido de carbón, pasar al aire fresco Powered Down / Apagado Dark / Apagado Dark / Apagado Silent / Silencio Silent / Silencio  TO SILENCE THE DETECTOR Press the test switch. The detector sounds again after 5 minutes if the alarm condition continues.  PARA SILENCIAR EL DETECTOR Presione el interruptor de prueba. El detector volverá a sonar después de 5 minutos si continúa la condición que originó la alarma.  NOTA IMPORTANTE:  • The Smoke, Heat, and Carbon Monoxide (CO) sensors each have unique MAC ID numbers (serial numbers) that are enrolled in separate zones. • Una vez registrado, el dispositivo no se puede usar con otro sistema hasta que sea removido del controlador actual. See the 24-hour Enrollment Deletion section below or the controller’s instructions.  Enroll the Device Services (Smoke, Heat, CO) 1. Remove the detector from the base plate (tamper switch must be faulted when enrolling). 2. Put the control panel in Zone Programming mode.  For Lyric Controller: Security > installer code > Program > (scroll down) > SiX Programming 3. Pull the battery tab to activate enrollment process (be sure batteries are seated properly to avoid a false low battery condition). If the battery tab has already been removed and the unit is powered up, press either Test switch for less than 3 seconds to activate the enrollment process. 4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the green LED lights steady for 3 seconds and the device announces successful enrollment.   If the LED does not light steady, enrollment failed. Retry by pressing either Test switch for less than 3 seconds.   All services (Smoke, Heat, and CO) are automatically enrolled in sequential (or next available) zone numbers with the following default attributes: Zone Device Type Zone Response Type Smoke Det. Smoke Detector Fire No Verification Heat Det. Heat Sensor Fire No Verification CO Det. Carbon Mono. Det. Carbon Monoxide   NOTE: Maintenance and CO End-of-Life are automatically enrolled for the respective smoke and CO zones. Upon either of these conditions, Contact ID code E386 “Low Maintenance Smoke” is sent for the respective zone.  Supervision: Detector supervision is factory set for 1 minute and is not programmable.  5. To assign zone descriptors for each of the zones and/or change device type or zone response type, select the zone then select Edit and make the desired changes. Press Save when done.  24-Hour Enrollment Deletion Use this procedure within 24 hours of initial enrollment to delete this device from the controller. This allows reenrollment in a specific controller in case enrollment in that controller failed (i.e., the device inadvertently enrolled in a different controller). This resets the device to factory default settings and removes the communication link data in the controller in which it is enrolled, allowing the device to be reenrolled in the desired controller. 1.  Press and hold both the Smoke and CO test switches simultaneously for 5 seconds, then release. The green light flashes rapidly.  2. Press and hold both buttons again for one second and release.  MOUNTING If the device is not in its final mounting location when enrolled, conduct Go/No Go tests (see controller’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary.    MONTAJE Si el dispositivo no está en su ubicación final de montaje cuando se registre, realice pruebas de Va/No Va (vea las instrucciones del controlador) para verificar que la intensidad de la señal sea adecuada. Ajuste la ubicación y orientación del dispositivo según ea necesario.
Download:
Mirror Download [FCC.gov]
Document ID3533559
Application IDwUw8dPA3VJlvtU1XEgbQRQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize106.23kB (1327840 bits)
Date Submitted2017-08-29 00:00:00
Date Available2017-08-30 00:00:00
Creation Date2017-08-19 13:59:04
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2017-08-19 13:59:17
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: E727032
FCC ID Filing: CFS8DLCOMR6

Navigation menu