Ademco 8DLLGB500 Lyric Smart Sensor - Glass Break User Manual Quick Install Guide

Honeywell International Inc. Lyric Smart Sensor - Glass Break Quick Install Guide

Quick Install Guide

   This wireless glassbreak detector is intended for use with Honeywell controls that support SiX™ series devices. FC: This wireless glassbreak detector is intended for use with Honeywell controls that support SiX™ series devices. SP: This wireless glassbreak detector is intended for use with Honeywell controls that support SiX™ series devices. PA: This wireless glassbreak detector is intended for use with Honeywell controls that support SiX™ series devices.     RF6GB Note: Once enrolled in a system, the RF6GB cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions device removal instructions.  FC: Note: Once enrolled in a system, the RF6GB cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions for device removal instructions. SP: Note: Once enrolled in a system, the RF6GB cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions for device removal instructions. PA: Note: Once enrolled in a system, the RF6GB cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions for device removal instructions.   Enroll / Enroll / Enroll / Enroll LEDS / LEDS / LEDS / LEDS    Mounting Locations / Mounting Locations /  Mounting Locations / Mounting Locations          Mounting Options / Mounting Options /  Mounting Options / Mounting Options  G1 Red G2 Status     Test Mode1     Event detected during Test Mode    Alarm detected during Test Mode  2  2 Low Battery detected during Test Mode      Power Up / Tamper switch pressed / FG-701 Activated before enrollment      Tamper Detected 1 Test Mode is 10 minutes. / Test Mode is 10 minutes / Test Mode is 10 minutes / Test Mode is 10 minutes 2 The LEDs are not visible during Normal Mode / The LEDs are not visible during Normal Mode / The LEDs are not visible during Normal Mode / The LEDs are not visible during Normal Mode BETA QUICK INSTALL GUIDE – 01/12/15 PLEASE GO TO THE BOTTOM OF THE NEXT PAGE FOR FCC/IC AGENCY STATEMENTS
  2014 Honeywell International Inc.  Honeywell and is a registered  trademark of Honeywell International Inc.   All other trademarks are  the properties  of their respective owners.  All rights reserved   2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747  www.honeywell.com/security  Ê800-15959)Š P/N 800-15962  01/15  Rev BETA  Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. FC: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. SP: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary. PA: Note: After enrolling and before mounting permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength. Adjust the device location and orientation as necessary.  Mount / Mount / Mount / Mount Consult the Control’s instructions to program the RF6GB Services: Tamper Switches, Sensitivity Setting and Temperature Sensing FC: Consult the Control’s instructions to program the RF6GB Services: Tamper Switches, Sensitivity Setting and Temperature Sensing. SP: Consult the Control’s instructions to program the RF6GB Services: Tamper Switches, Sensitivity Setting and Temperature Sensing. PA: Consult the Control’s instructions to program the RF6GB Services: Tamper Switches, Sensitivity Setting and Temperature Sensing.  Sensitivity Setting Approximate Range High * 4.6-7.6m / 15-25 ft.  Medium  3-4.6m / 10-15 ft.  Low 1.5-3m / 5-10 ft.  Lowest  0-1.5m / 0-5 ft.  * Factory default / Valeurs par défaut du fabricant / Defecto de fábrica / Padrão de fábrica  Program / Program /  Program / Program Approval Listings: FCC / IC UL639 ULC S306-03 RoHS  Specifications: Range: 0’- 25’/ 0 – 7.6m; Selectable   RF Frequency: 2.4GHz Battery: 1 x 3V, Lithium; Panasonic CR123A, Duracell DL 123, Duracell DL 123A, Honeywell 466 Tamper: Cover and Wall Operating Temperature:  32° – 122° F / 0° – 50° C Relative Humidity:  5 – 95%, non-condensing  Dimensions: 3.78” Diameter x 1.14” Thick / 96 mm Diameter x 29mm Thick Product must be tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année / El producto debe ser probado al menos una vez al año / O produto deve ser testado pelo menos uma vez por ano  Replace Battery / Replace Battery /  Replace Battery / Replace Battery BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. FC:BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. SP: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. PA: BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children. Support / Support / Support / Support http://www.security.honeywell.com/hsc/resources/MyWebTech/ U.S. warranty / U.S. warranty / U.S. garantie / U.S. garantia www.honeywell.com/security/hsc/resources/wa FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception indésirable. RF Exposure Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.   MyWebTech  Warranty

Navigation menu