Ademco 8DLLKP500 Lyric Smart Peripheral - Wireless Keypad User Manual
Honeywell International Inc. Lyric Smart Peripheral - Wireless Keypad Users Manual
Ademco >
Users Manual
Installation and Setup Guide Ref: LKP500-EN FEATURES & NOTES LED Status indicators • Wireless alpha keypad serves as a secondary keypad for controlling the Lyric Smart Controller’s security functions. • Uses SiX™ technology protocol for secure, bidirectional communication. • Use up to eight (8) keypads with the Lyric Smart Controller. • Easy enrollment in the Controller. • Mounts to a wall or desk stand. • Supervised; supervision time is 60 minutes (cannot be changed). • Locate the keypad within 300 feet of the Lyric Smart Controller. • Powered by an external 110VAC input/9VDC output power pack (supplied). • Battery pack (7.2VDC) provides 24-hour backup power (supplied). Indicator Security Shield Panic Color OFF BLINKING ON Green System not ready AC Loss System ready to arm Red System disarmed AC Loss Entry Delay with AC Loss Exit Delay System armed Red Not active N/A Active, waiting for selection of panic alarm type INSTALL THE BATTERY AND CONNECT THE POWER SUPPLY IMPORTANT: DO NOT connect the power supply to an AC outlet yet. See “Enroll the Keypad.” MOUNT THE KEYPAD ENROLL THE KEYPAD The keypad must be enrolled in the Lyric Smart Controller before it can be used. 1. At the Smart Controller, enter Programming mode and follow the control’s instructions to enter keypad enrollment mode (Program > RF Keypad > Add New > Serial Number). • RF keypads are assigned zone numbers, starting with zone 850. Selecting “Add New” automatically assigns the next available RF keypad zone number. 2. While the Controller is in enrollment mode, plug the keypad’s power pack into a 24hr, non-switchable outlet. 3. After successful pairing, keypad • The keypad automatically attempts to pair with the Controller. • If enrollment is not successful, press any key on the keypad to restart the pairing process or disconnect and reconnect power. displays Disarmed, Ready. • When enrolled, the keypad’s ID number appears on the Controller’s Programming screen. 4. After enrollment, program and save the keypad’s zone options (zone descriptor, etc.) at the Smart Controller. IMPORTANT: Once enrolled, the keypad cannot be used with another control panel until it is un-enrolled from the current controller. See the Smart Controller’s Programming Guide for details on removing devices. BATTERY REPLACEMENT IMPORTANT: Unplug the keypad power supply BEFORE starting. Reconnect power after the keypad is re-mounted. SPECIFICATIONS Physical: 6.7” W x 5.4” H x 0.9” D (170mm x 136mm x 22mm) Frequency: 2.4 GHz Battery Pack: Part number 300-06868: 7.2V, 6xAAA, 6x600mAH, NiMH Transformer: Part number 300-07332US: 110VAC input/9VDC, output 1A, 2-prong LCD Display: 2x16 Sounder: Speaker/Codec Notes on Keypad Supervision • When a trouble condition is detected, the keypad displays a trouble message and begins to beep. • Press any key to stop the beeping. • Keypad supervision time is set at 60 minutes (cannot be changed). USING THE KEYPAD The Lyric Smart Keypad is used to control the security functions of the Lyric Smart Controller. The keypad also features two menus for setting various options (see Keypad Settings Menu section below). Refer to the Lyric Smart Controller’s User Guide for more information about Security functions. Keypad System Functions NOTE: Before entering any command, the keys must be lit (key lighting automatically turns off after a period of inactivity, if the Auto Off option is enabled). If the keys are unlit, press any key before continuing. FUNCTION PRESS NOTES Arm Away Away then enter user code. Exit delay begins. System arms in Away mode. (see User Guide for Auto-Stay option, if enabled) Arm Stay Stay then enter user code. Exit delay begins. System arms in Stay mode. Quick Arm Hold Security Shield for 3 seconds, then select Away or Stay arming mode. Quick Arm allows arming the system without entering a user code. Exit delay begins. System arms in selected mode. With system not ready: Away or Stay then enter user code. Press Select when prompted. System automatically bypasses all faulted zones and arms in the selected mode. NOTE: Force Bypass must be enabled at the controller for this feature to operate. Hold Panic key for 3 seconds, then select: • Fire • Police (default = silent) • Medical The 3 Panic keys light red until one is selected, then: • An alarm signal is sent to the central station • Alarm sounding starts (if programmed to do so) • If the selected Panic function is programmed to be silent, the keypad returns to normal state. (if programmed) Bypass Zones (if zones are faulted) Panic (if programmed) Disarm Security Shield, then enter user code. System disarms. Cancel Silent Panic Alarm Security Shield, then enter user code. Panic alarm is canceled. Status Display security status Cancel The Security shield is a single key; the and icons are not separate buttons. Security status is indicated by color: Displays the system’s current security status. (Armed/Disarmed, Away/Stay/Custom arming mode, exit countdown, Ready/Not Ready, Fault, Trouble and Bypass conditions.) Cancel Shield State Green unlit Red Cancels the entry and returns to Status display. steady Meaning not ready to arm (press and hold Status key to show faults) ready to arm steady system armed blinking system arming, exit delay in progress unlit zone fault or zone trouble Keypad Settings Menu There are two Settings menus, one for users and one for the installer. Use the Select, Scroll and Cancel keys to navigate the menus. Key Function Select ( 1 ) Press and hold to start the Settings menu. Also used to select menu options. Scroll ( 0 ) Press to scroll through the available menus and the settings in menus. Cancel (Away) Cancels the current entry and returns to Status display. To Access User Settings 1. Press and hold the Select ( 1) key until the menu begins. 2. Use the Scroll (0) key to scroll the settings. 3. Use the Select key to choose the desired menu item. 4. Use the Scroll key to toggle the menu options. 5. Press the Select key to choose an option. 6. Press the Select key again to save your settings. User Settings Menu (brackets [ ] indicate default values) Setting Options Chime Notes On: keypad beeps when a zone is faulted if Chime mode is turned on at the control [On]/Off Off: keypad does not beep upon faulted zones Exit Tone (beeps) [On]/Off On: keypad beeps during exit delay period Entry Tone (beeps) [On]/Off On: keypad beeps during entry delay period To Access Installer Settings 1. Press and hold the Select ( 1) key until the menu begins. 2. Enter Installer Code. The panel displays “Advanced Menu Use Scroll Key”. 3. Use the Scroll (0) key to scroll the menus. 4. Use the Select key to choose the desired menu item. 5. Use the Scroll key to toggle the menu options. 6. Press the Select key to choose an option. 7. Press the Select key again to make settings or choose options. Installer Settings Menu Setting Options Default Keypad Cancel/Delete Firmware Use Scroll to choose firmware components App (version level) Touch (touch screen) Boot (boot loader) RF6 (comm. protocol) Displays the various keypad component firmware versions. See Firmware Upgrades section for details on upgrading the keypad firmware. Off: keypad does not beep during exit delay Off: keypad does not beep during entry delay Adjusts the desired volume for keypad announcements. Voice Volume [Med]/High/Off Key Level [Med]/High/Low Adjusts the brightness of key lighting. Display Level [Med]/High/Low Adjusts the brightness of the display. Backlight (for keys) Always On/[Auto Off] Auto-Off: Off: mutes arm/disarm announcements; alarms are always announced Always On: display remains always on display turns off after a period of inactivity. Firmware Upgrades Software upgrades may be available for this product. Upgrades can be installed manually using the Lyric Smart Controller, or can be done via AlarmNet 360. To upgrade the keypad firmware using the Lyric Smart Controller, go to the following Controller menu and follow the prompts: Security > Tools > enter Code > Advanced > Upgrade Sensor Firmware RF Exposure Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. SUPPORT & WARRANTY For the latest documentation and online support information, please go to: https://mywebtech.honeywell.com/ For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa. Ê800-19484pŠ 800-19484 4/15 Rev. A BETA Notes Delete = resets the keypad to its factory default settings and unenrolls the keypad from the Lyric system. However, the keypad will remain in the Lyric Controller’s list of connected devices. If Delete is used, make sure to un-enroll the keypad at the controller. Cancel = exits from Default Keypad screen without making a change. FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception indésirable. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright 2015 Honeywell International Inc. www.honeywell.com/security
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Modify Date : 2015:04:25 10:42:35-04:00 Create Date : 2015:04:25 10:42:33-04:00 Metadata Date : 2015:04:25 10:42:35-04:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:e82643bc-c64d-4d59-ba2e-80aa6d4a6760 Instance ID : uuid:e8f0f31c-7d3e-423a-bce7-432a44b271f0 Format : application/pdf Title : Creator : Producer : Adobe PDF Library 11.0 Page Layout : OneColumn Page Count : 2 Author :EXIF Metadata provided by EXIF.tools