Ademco CTU-K07 Access Control Terminal User Manual Tema1 0 TSTAxx IM 1 1 US 2

Honeywell International Inc Access Control Terminal Tema1 0 TSTAxx IM 1 1 US 2

manual

Download: Ademco CTU-K07 Access Control Terminal User Manual Tema1 0 TSTAxx IM 1 1 US 2
Mirror Download [FCC.gov]Ademco CTU-K07 Access Control Terminal User Manual Tema1 0 TSTAxx IM 1 1 US 2
Document ID287359
Application IDbHWyzS3lNFcYZa1XT7laZA==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize46.05kB (575572 bits)
Date Submitted2002-12-04 00:00:00
Date Available2002-12-04 00:00:00
Creation Date2002-12-04 10:11:08
Producing SoftwareAcrobat PDFWriter 4.05 for Windows NT
Document Lastmod0000-00-00 00:00:00
Document TitleTema1.0_TSTAxx_IM_1.1_US_2.doc
Document CreatorTema1.0_TSTAxx_IM_1.1_US_2.doc - Microsoft Word
Document Author: jevans

TS TAxx
Integrated Interactive Terminals
Installation Manual
TS TAxx
TABLE OF CONTENTS
FCC NOTICE...................................................................................................4
Canadian Compliance Statement...........................................................4
PRELIMINARY OPERATIONS............................................ 5
Mounting Instructions......................................................................................5
Electrical Connections ....................................................................................6
Cabling Arrangements ....................................................................................7
INSTALLATION ............................................................... 8
Attaching the Terminal Support Plate ............................................................8
Hooking Up the Terminal ................................................................................9
Connecting the Cables..................................................................................10
Jumpers.........................................................................................................13
Auxiliary Connections ...................................................................................14
Closing the Terminal .....................................................................................15
Applying the Entry/Exit Labels......................................................................16
TECHNICAL SPECIFICATIONS ....................................... 17
TemaServer TS TAx3 (CTU-K03 code 1500064FA)................................17
Spare Parts............................................................................................18
TemaServer TS TAx4 (CTU-K04 code 1500087DA) ......................................19
Spare Parts............................................................................................20
TemaServer TS Tax5 (CTU-K05 code 15000...) ............................................21
Spare Parts............................................................................................22
TemaServer TS Tax7 (CTU-K07 code 15000....) ...........................................23
Spare Parts............................................................................................24
Optional Parts................................................................................................25
Versione: 1.0 US
TABLE OF CONTENTS
Page 3
FCC NOTICE
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, these is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by tuning the equipment off and on, the
user is encouraged to try to correct the interference by one or more the
following measures:
-----
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: any modification or change not expressely approved by the party
reponsible for compliance could void the user’s authority to operate the
equipment.
Canadian Compliance Statement
This Class B Digital apparatus meets all the requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe B respecte les exigences du Reglement
sur le material broilleur du Canada.
Page 4
FCC NOTICE
PRELIMINARY OPERATIONS
Mounting Instructions
It is recommended that you attach the cables to wall box. The position
selected for mounting the box must satisfy the requirements laid down for the
mounting area and allow the necessary space for opening the box (see
Figure 1). In addition, there must be sufficient space to the right and rear of
the unit to allow access to the box with a screwdriver.
tube
14cm
12cm
mounting area
32cm
encased
box
work area
floor
cables
Figure 1: Space requirements for mounting
Mounting Instructions
Page 5
Electrical Connections
The TemaServer is powered at low voltage (12VAC) by means of a
transformer connected to the 115/230V 50/60Hz network switch. This switch
must be positioned prior to the TemaServer. The cables connecting the
transformer and the TemaServer must be at least AWG20 and no more than
10m long (see Figure 2).
I N
yellow-green
230V 50Hz or
115V 60Hz
yellow-green
125mA
black
brown
transformer
module
115/230V
12V
oragne
gray
10m max.
GROUND
Figure 2: Electrical connections
Page 6
Electrical Connections
Cabling Arrangements
It is recommended that you attach the cables to wall box. The box must be
placed 120cm from the ground (see Figure 3).
It is strongly recommended that you run the LAN cable into a separate tube
from the one used for the 12V∼ power cable. If you wish to keep the LAN
cable and the 12V∼ power cable together, make sure that the 12V∼ cable is
shielded. You must not on any account attempt to route the LAN cable and
the primary power cable (230V∼) together.
encased box
tube
120 cm
cables
floor
Figure 3: Cabling arrangements
Cabling Arrangements
Page 7
INSTALLATION
Attaching the Terminal Support Plate
To attach the terminal support plate, drill two holes in the wall in which to
place the plastic anchors that hold up the support plate (see Figure 4). Make
sure that the box attached to the wall is aligned with the niche on the
lower part of the support plate (use a ∅ 6mm parallel tip flat head
screwdriver).
anchor
anchor
Figure 4: Terminal support plate
Page 8
Attaching the Terminal Support Plate
Hooking Up the Terminal
To hook up the terminal, follow the steps described below (see Figure 5):
1. Attach the upper part of the terminal to the upper hooks on the support
plate.
2. Insert the cables into the terminal through the specified openings.
3. Tighten the two screws that secure the terminal to the support plate (use a
∅ 6mm parallel tip flat head screwdriver).
1) Attach terminal to hooks
2) Insert
cables
3) fasten the screws
Figure 5: Hooking up the terminal
Hooking Up the Terminal
Page 9
Connecting the Cables
To connect the cables, follow these steps:
1. Before connecting the cables, insert the power supply jumpers.
WARNING
Do not press the anti-opening tamper during installation and/or
maintenance of the unit.
2. Line up the cables with the grooves at the back of the terminal (see Figure
6) and screw in the small plate which serves as a cable clamp (use a ∅
5mm Philips screwdriver).
Lock cables
Fasten cable clamp
board (8 screws)
Figure 6: Connecting the cables
3. Attach the wire pin connectors to the terminals located on the lower part of
the terminal unit. (use a ∅ 3mm flat head screwdriver).
4. Insert the cable in the corresponding connector (see Figure 7) to complete
the connection to the LAN Ethernet 10BaseT (twisted pair).
Figure 9 illustrates the connections and settings of jumpers JP2 and JP3 on
the display control board. Make sure that both jumpers are in the position
shown in Figure 9 (MAG-TEK interface).
Page 10
Connecting the Cables
When 12V of electric current is supplied (see Figure 8), the terminal
commences operation and the green “RUN” LED lights up (see Figure 7)
Battery
JTAG
Battery fuse (F1)
Battery cable
P10 wall-tamper
(jumper)
tamper
P12 connector
for production
jumper LEAVE OPEN!
Status LED
TX (red)
RX (green)
Collision (red)
RUN (green)
RESET button
JP4,JP3 jumpers
Ethernet (test)
Power supply
fuses
Plug-in Ethernet
I/O terminal box
power supply (12V)
Ethernet 10BaseT
Figure 7: Main circuit components
orange
grey
green-yellow
Figure 8: Close-up view of the 12V supply
Connecting the Cables
Page 11
lamp cable for rear lighting of LCD
jumper JP2
pin 1 -2 = MAG-TEK
pin 2 -3 = bidirectional
jumper JP3
pin 1 -2 = MAG-TEK
pin 2 -3 = Proxy
serial interface
TemaServer mother
board connection
keyboard cable
(4 rightmost keys)
keyboard cable
(4 leftmost keys)
connection with
LCD controller
keyboard cable
(6 central keys)
4x4 keyboard
(optional)
Figure 9: Display board details
Page 12
Connecting the Cables
Jumpers
For normal operation, configure the jumpers on the main board as specified
in Table 2.
Jumper
P10
P12
JP3
JP4
Function
auxiliary tamper
Default state
Inserted
auto -update
of Open
firmware
Ethernet full duplex
Open
Ethernet loopback
Inserted
Table 1: Configuration of jumpers on main board
Configure the jumpers on the display board as specified in Table 2.
Jumper
JP2
JP3
Jumpers
Function
data transmission
Default state
inserted between pins 1
and 2
data receipt
inserted between pins 1
and 2
Table 2: Configuration of jumpers on display board
Page 13
Auxiliary Connections
The I/O plug-in board features a connector that includes two opto-coupled
inputs and two relay outputs, as illustrated in Figure 10.
jumper
relay 1
jumper
relay 2
jumpers
input 1
jumpers
input 2
relay output 1
relay output 1
relay output 2
relay output 2
connector to
mother
board
input 1 input 1 +
input 2 input 2 +
Connection to LCD control board
Figure 10: Auxiliary connections
Note:
When the cables go externally, shielded cables must be used. The
cable’s shield must be connected to ground connector
You can define the operational mode of each relay by positioning the
appropriate jumpers as follows:
• Jumper «OUT1» between 12 (NO) for relay 1 normally open
• Jumper «OUT1» between 23 (NC) for relay 1 normally closed
• Jumper «OUT2» between 12 (NO) for relay 2 normally open
• Jumper «OUT2» between 23 (NC) for relay 2 normally closed
You can define the operational mode of each input by positioning the
appropriate jumpers as follows:
• Jumpers «IN1» between 12 for input 1 on dry contact
• Jumpers «IN1» between 23 for input 1 opto-coupled
• Jumpers «IN2» between 12 for input 2 on dry contact
• Jumpers «IN2» between 23 for input 2 opto-coupled
Page 14
Auxiliary Connections
Closing the Terminal
To close the terminal, follow these steps:
1. Connect both contacts of the battery cable to the battery
2. Make sure that the rubber gasket is correctly positioned.
3. Close the terminal cover by rotating it.
4. Fasten the cover with the two special screws (see Figure 11) located on
the side of the terminal (use a TORX anti-tamper TX10 screwdriver).
Fasten the
special screws
IN
Figure 11: Closing the terminal
Closing the Terminal
Page 15
Applying the Entry/Exit Labels
Apply the two entry/exit labels to the magnetic reader according to the preconfigured transit direction. Make sure that you place the labels in the
appropriate hollows (TS-Tax3/TS-Tax4: see details in Figure 12 and Figure
13).
O U T
ß EXIT
IN
ENTRY à
Figure 12: Entry/exit labels
IN
ß ENTRY
EXIT à
Figure 13: Entry/exit labels
Page 16
Applying the Entry/Exit Labels
TECHNICAL SPECIFICATIONS
TemaServer TS TAx3
(CTU-K03 code 1500064FA)
Parameter
DC power supply
Value
12VDC±15% 500mA nominal (6W)
600mA max (for fast battery recharge)
AC power supply
12VAC±15% 50Hz
500mA (nominal)
600mA max (for fast battery recharge)
Power supply via TRN01 230VAC ±15% 50Hz
Transformer
30mA nominal (7VA)
40mA max. (for fast battery recharge)
Weight (including frame)
3.5kg (+ transformer TRN01 = 500g)
Size
220x305x80 mm
IP Protection Rating
IP55
0…50 °C
Environmental
temperature for correct
operation
10BaseT standard cable on RJ45
LAN Ethernet
connection
Proxy antennae
Double antenna 125KHz for HID cards
Read distance 0…50mm
Expansions
2 slots for 1-unit plug -in cards
(or une 2 -units plug-in card)
Relay outputs
Number of outputs: 2
Max. load allowed:
50VDC 1A
TemaServer TS TAx3
(CTU-K03 code 1500064FA)
Page 17
Inputs
Number of inputs: 2
• opto-coupled mode
resistance: 2.2 Kohm
logic level high:
>4 VDC (max. positive +18 VDC)
logic level low:
<1 VDC (max. negative –0.5 V DC)
• self powered mode (dry contacts)
open contact: > 2Kohm
closed contact: < 100 ohm (10mA)
Regulations compliance
Directive EMC 89/336/EEC, 92/31/EEC,
Directive Low Voltage 72/23/EEC, 93/68/EEC:
EN60950, EN55024, EN55022, EN61000-3-2/3,
EN 300 330
Includes a part with FCC-ID: HS9-CTU-K03
Spare Parts
Fuses
F1 : 2A 250V delayed
F2 : 1A 250V delayed
F3 : 1A 250V delayed
Battery
6V 1.2 Ah code 1801026
Figure 14: TemaServer TS TAx3
Page 18
TemaServer TS TAx3
(CTU-K03 code 1500064FA)
TemaServer TS TAx4
(CTU-K04 code 1500087DA)
Parameter
Value
DC power supply
12VDC±15% 500mA nominal (6W)
600mA max (for fast battery recharge)
AC power supply
12VAC±15% 50Hz
500mA (nominal)
600mA max (for fast battery recharge)
Power supply via TRN01 230VAC ±15% 50Hz
Transformer
30mA nominal (7VA)
40mA max. (for fast battery recharge)
Weight (including frame)
3.5kg (+ transformer TRN01 = 500g)
Size
220x305x80 mm
IP Protection Rating
IP55
0…50 °C
Environmental
temperature for correct
operation
10BaseT standard cab le on RJ45
LAN Ethernet
connection
Proxy antenna
Antenna 139KHz for WSE cards
Read distance 0…30mm
Expansions
2 slots for 1-unit plug -in cards
(or une 2 -units plug-in card)
Relay outputs
Number of outputs: 2
Max. load allowed:
50VDC 1A
TemaServer TS TAx4
(CTU-K04 code 1500087DA)
Page 19
Inputs
Number of inputs: 2
• opto-coupled mode
resistance: 2.2 Kohm
logic level high:
>4 VDC (max. positive +18 VDC)
logic level low:
<1 VDC (max. negative –0.5 V DC)
• self powered mode (dry contacts)
open contact: > 2Kohm
closed contact: < 100 ohm (10mA)
Regulations compliance
Directive EMC 89/336/EEC, 92/31/EEC,
Directive Low Voltage 72/23/EEC, 93/68/EEC:
EN60950, EN55024, EN55022, EN61000-3-2/3,
EN 300 330
Includes a part with FCC-ID: C4P DR4201
Spare Parts
Fuses
Battery
F1 : 2A 250V delayed
F2 : 1A 250V delayed
F3 : 1A 250V delayed
6V 1.2 Ah code 1801026
Figure 15: TemaServer TS TAx4
Page 20
TemaServer TS TAx4
(CTU-K04 code 1500087DA)
TemaServer TS Tax5
(CTU -K05 code 1500114DA)
Parameter
DC power supply
Value
12VDC±15% 500mA nominal (6W)
600mA max (for fast battery recharge)
AC power supply
12VAC±15% 50Hz
500mA (nominal)
600mA max (for fast battery recharge)
Power supply via TRN01 230VAC ±15% 50Hz
Transformer
30mA nominal (7VA)
40mA max. (for fast battery recharge)
Weight (including frame)
3.5kg (+ transformer TRN01 = 500g)
Size
220x305x80 mm
IP Protection Rating
IP55
0…50 °C
Environmental
temperature for correct
operation
10BaseT standard cable on RJ45
LAN Ethernet
connection
Proxy antenna
Antenna:
Exciter Field
125KHz
Receive
62.5Khz
For FlexPass Prox cards
Read distance 0…50mm
Expansions
2 slots for 1-unit plug -in cards
(or une 2 -units plug-in card)
Relay outputs
TemaServer TS Tax5
Number of outputs: 2
Max. load allowed:
50VDC 1A
(CTU-K05 code 1500114DA)
Page 21
Inputs
Number of inputs: 2
• opto-coupled mode
resistance: 2.2 Kohm
logic level high:
>4 VDC (max. positive +18 VDC)
logic level low:
<1 VDC (max. negative –0.5 V DC)
• self powered mode (dry contacts)
open contact: > 2Kohm
closed contact: < 100 ohm (10mA)
Regulations compliance
Directive EMC 89/336/EEC, 92/31/EEC,
Directive Low Voltage 72/23/EEC, 93/68/EEC:
EN60950, EN55024, EN55022, EN61000-3-2/3,
EN 300 330
Includes a part with FCC-ID: HS9-CTU-K05
Spare Parts
Fuses
Battery
F1 : 2A 250V delayed
F2 : 1A 250V delayed
F3 : 1A 250V delayed
6V 1.2 Ah code 1801026
Figure 16: TemaServer TS Tax5
Page 22
TemaServer TS Tax5
(CTU-K05 code 1500114DA)
TemaServer TS Tax7
(CTU -K07 code 1500118AA)
Parameter
DC power supply
Value
12VDC±15% 500mA nominal (6W)
600mA max (for fast battery recharge)
AC power supply
12VAC±15% 50Hz
500mA (nominal)
600mA max (for fast battery recharge)
Power supply via TRN01 230VAC ±15% 50Hz
Transformer
30mA nominal (7VA)
40mA max. (for fast battery recharge)
Weight (including frame)
3.5kg (+ transformer TRN01 = 500g)
Size
220x305x80 mm
IP Protection Rating
IP55
0…50 °C
Environmental
temperature for correct
operation
10BaseT standard cable on RJ45
LAN Ethernet
connection
Proxy antenna
Antenna 13.56MHz for Mifare cards
Read distance 0…30mm
Expansions
2 slots for 1-unit plug -in cards
(or une 2 -units plug-in card)
Relay outputs
Number of outputs: 2
Max. load allowed:
50VDC 1A
TemaServer TS Tax7
(CTU-K07 code 1500118AA)
Page 23
Inputs
Number of inputs: 2
• opto-coupled mode
resistance: 2.2 Kohm
logic level high:
>4 VDC (max. positive +18 VDC)
logic level low:
<1 VDC (max. negative –0.5 V DC)
• self powered mode (dry contacts)
open contact: > 2Kohm
closed contact: < 100 ohm (10mA)
Regulations compliance
Directive EMC 89/336/EEC, 92/31/EEC,
Directive Low Voltage 72/23/EEC, 93/68/EEC:
EN60950, EN55024, EN55022, EN61000-3-2/3,
EN 300 330
Includes a part with FCC-ID: HS9-CTU-K07
Spare Parts
Fuses
Battery
F1 : 2A 250V delayed
F2 : 1A 250V delayed
F3 : 1A 250V delayed
6V 1.2 Ah code 1801026
Figure 17: TemaServer TS Tax7
Page 24
TemaServer TS Tax7
(CTU-K07 code 1500118AA)
Optional Parts
TORX TX10 screwdriver
Optional Parts
Code 1500108AA
Page 25
Internet:
http://www.temaline.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 27
Creator                         : Tema1.0_TSTAxx_IM_1.1_US_2.doc - Microsoft Word
Create Date                     : 2002:12:04 10:11:08
Title                           : Tema1.0_TSTAxx_IM_1.1_US_2.doc
Author                          : jevans
Producer                        : Acrobat PDFWriter 4.05 for Windows NT
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HS9-CTU-K07

Navigation menu