K5510  12/00®4XHVW610LFURZDYH3,53ROOLQJ/RRS0RWLRQ6HQVRU,167$//$7,21,16758&7,216GENERAL INFORMATIONThe Quest 2260SN is a Microwave/PIR polling loop motion detectorthat offers unmatched levels of operation with the advancedfeatures listed below.This detector is designed for use with control panels that supportserial number polling loop devices . It is not for use with panels thatsupport only DIP switch addressing.•Accu-Trak environmental test feature allows the installer tocheck for environmental disturbances on both the PIR andmicrowave channels at the same time.•Conditional Microwave Mode saves current in large installations.•Automatic adaptation to environmental disturbances.•Rejection of fluorescent light disturbance.•Continuous supervision of both PIR and microwave.•Advanced dual-slope temperature compensation assures optimaldetection.•Vertical and horizontal pattern adjustability.•Tampered front cover and back case.This detector is shipped with its standard wide-angle lens installedto provide coverage of 60 ft x 75 ft.Optional swivel-mounting bracket is available under part number998SB.SPECIFICATIONSDetection Method: Dual-technology Microwave/PIRCoverage: Standard Lens 60' x 75' (18.3m x 22.9m)Detection Zones: Standard Lens: 38 zones (11 long range, 11over 6 intermediate,5 over 5 short range, 1Look-Down Zone)Pulse Processing: Standard or Intermediate, selectable via aDIP SwitchDetectable Walk Rate: 0.5-10 ft/sec (0.15-3m/sec)Mounting Height: 7-8 ft (2.1-2.4m),Indicator: Red and Green LED (see LEDINDICATIONS); enabled/disabled viaa DIP switchInput Voltage: 9-13VDC at polling loop terminals withreverse polarity protectionCurrent: 3mA nom. (Conditional Microwave mode)6mA nom. (Normal mode), with LEDdisabled8mA nom. (alarm, with LED enabled)Up to 8mA nominal during warm-upStandby: Power source should be capable of at least4 hours of battery standbyOperating Temp: -14°F to +122°F (-10°C to +50°C)(0°C to +50°C for UL installations)Operating Humidity: Up to 95% RH (max.), non-condensingDimensions: 2.8"W x 5.2"H x 2.2"D(71mm x 132mm x 56mm)COVERAGE & LOCATION CONSIDERATIONSCombined protective patterns are shown in Figure 1 for a nominalmounting height of 7.5 ft (2.3m). The microwave detection patternshown in Figure 1 represents coverage in open space. In practicalapplication, when the detector is bounded by ceiling, floor, andwalls, reflections can occur.SELECTING A MOUNTING LOCATIONThe detector responds to changes in energy that occur when anintruder moves into the combined protection pattern. Best coveragewill be obtained if the mounting site is selected so that the likelydirection of intruder motion is generally across the pattern andangles slightly toward the detector.037.5'(11.5 m)37.5'(11.5 m) 05'(1.5m) 10'(3m) 15'(4.5m) 20'(6m) 25'(7.5m) 30'(9m) 35'(10.5) 40'(12m) 45'(13.5) 50'(15m) 55'(16.5) 60'(18m)5'(1.5m) 10'(3m) 15'(4.5m) 20'(6m) 25'(7.5m) 30'(9m) 35'(10.5) 40'(12m) 45'(13.5) 50'(15m) 55'(16.5) 60'(18m)MICROWAVE PATTERNMICROWAVEPATTERN7.5' (2.3m)1' (0.3m)2' (0.6m)3' (1.0m)4' (1.2m)5' (1.5m)6' (1.8m)7' (2.1m)02260SN-001-V0SIDE VIEWTOP VIEWINSTALLATION HINTSThe detector is remarkably resistant to false alarm hazards, but thefollowing recommendations should be observed.•Never install the detector in an environment that causes adisturbance in one technology. Good installations start with bothLEDs OFF when in the Accu-Trak environmental test mode and thereis no target motion.•Do not mount on an unstable surface. Locate the unit on a sturdyinside wall whenever possible. Avoid sources of vibration such as loosefitting doors and walls that shake when heavy traffic exists.•Do not install on or close to metal structures such as metal doorframes, shelves, etc.•Do not include space heaters in the protective pattern wheneverpossible, to avoid rapid temperature changes and vibrations fromfans.•ALL microwave transmission penetrates most building materials(except metal, which reflects transmission). Moving objects outside ofthe protected area may be detected unless the microwave sensitivitycontrol is kept at as low a setting as possible, to minimize penetration.•Make sure the detection area does not have obstructions (curtains,screens, large pieces of furniture, plants, etc.) that may block the PIRportion of the coverage pattern.
– 2 –MOUNTINGMount the unit to a firm vertical surface. The wall wiring holeshould be no more than 5/16" (8mm) diameter.1. Remove the front cover by twisting a screwdriver blade in thegroove between cover and base at the bottom edge of the caseand then lifting the cover off.2. Remove the circuit board: Loosen (do not remove) the verticaladjustment screw, slide the PC board down, then spread thePCB holding tabs (see Figure 3), and remove the PC board.3. Break out desired mounting and wire entry holes in the backcase. Refer to Figure 2. Knockout screw holes “A” in the backcase are for normal surface mounting on a wall. Knockout screwholes “B” are for corner mounting.Also break out the wire entry hole marked X in Figure 2. Ifsurface wiring is to be used, break out the section at the bottomof the back case, and run the wiring up the wiring channel atthe back of the case to hole “X”.If the back case tamper is to be used, use an additional screwthrough hole C to secure the back case to the mounting surface.4. Feed wiring (unpowered) coming from the wall through the wireaccess hole near the top of the detector case back. If surfacewiring is used, use bottom access hole and use the wiringchannel in the case back for routing the wires.5. Mount the base and reinstall the PC board.6. Vertically align the PC board in accordance with Table 1(Vertical Pattern Adjustment section below) beforetightening the vertical adjustment screw.7. Refer to WIRING CONNECTIONS section before replacing cover.BREAK - OUT HOLES"A" FOR NORMAL SURFACE      MOUNTING (4)"B" FOR CORNER      MOUNTING (4)"C" SCREW HOLE FOR BACK      CASE TAMPER"X" FOR WIRING ENTRY ACTS AS BACK CASETAMPERAFTER MOUNTING, USEADDITIONAL SCREW HERE FOR TAMPERBREAK - OUT SECTION (BEHIND) FOR SURFACEWIRINGWIRING CHANNELBAABCBAABXUSED TO SECURE PC BOARD (DO NOT REMOVE)2260SN-002-VOFigure 2. CASE BACKWIRING CONNECTIONSAll wires should have been fed through the wire access slot at thetop of the detector base near the terminal block. Connect pollingloop wiring to the screw terminals as shown in Figure 3. Seal anyopenings in the base with foam or RTV (not supplied) to preventdrafts and insects from entering the unit. Apply power only after allconnections have been made and are inspected.VERTICAL PATTERN ADJUSTMENTThe protection pattern can be moved up or down by verticaladjustment of the lens as follows.1. Remove the front cover as indicated in step 1 of theMOUNTING section.2. Loosen the PCB screw on the lower right of the board (see Fig.3), and slide the board into the appropriate position, using thescale to the right of the screw. Use Table 1 which shows theproper setting for the desired range.Table 1. Vertical Adjustment SettingsDesired Range PCB Position30 ft (9.1m) position 440 ft (12.2m) position 250 ft (15.2m) position 160 ft (18.3m) position 00+-4MIN MAXDIPSWITCHCIRCUIT BOARDHOLDING TABS(BEND OUTWARD TO RELEASE BOARD)PIRDETECTORREDLED GREENLED FRONT COVERTAMPER SWITCHMICROWAVEDETECTORMICROWAVE SENSITIVITY(TURN CLOCKWISE TOINCREASE SENSITIVITY)PCB SCREW(LOOSEN TO CHANGEVERTICAL PATTERNUSING SCALE AT RIGHT)1 2 3 4 5 6MARKER2260SN-003-V1POLLINGLOOP12Figure 3. INTERIOR OF DETECTORHORIZONTAL PATTERN ADJUSTMENTThe protection pattern can be moved to the left or right by horizontaladjustment of the lens, as follows.1. Remove the front cover as indicated in step 1 of the MOUNTINGsection.2. Remove the lens holder in the front cover by squeezing the two outersides of the holder together, releasing it from the side clips (seeFigure 4). Then pull the holder out, exposing the lens.3. Slide the lens slightly to the left or right to change the horizontalpattern as desired.4. Reinstall the lens holder. It should snap firmly in place beneath theholding tabs on each side.5. Replace the front cover.IMPORTANT: After any adjustment, conduct a walk test to ensureproper coverage of the area to be protected. See theTest Procedures section.LENS HOLDER ASSEMBLY(REMOVE FOR ACESS tO LENS)HOLDING TABS(2 EACH SIDE)BEND INWARD TORELEASE LENS HOLDERLENS(BEHIND LENSHOLDER ASSEMBLY)2260SN-004-V0Figure 4.  ACCESSING THE LENS04PCB SHOWN POSITIONEDFOR A SETTING OF "1"PCBSCREW SCALE0-4USE ASMARKER2260SN-005-V0
Download:
Mirror Download [FCC.gov]
Document ID140342
Application IDwMHl7+v/zN+U0yIGmBCV8g==
Document DescriptionExhibit D Users manual per 2 1033 b 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.6kB (132505 bits)
Date Submitted2001-03-14 00:00:00
Date Available2001-03-13 00:00:00
Creation Date1910-10-10 21:44:53
Producing SoftwareAcrobat Distiller 3.02
Document Lastmod0000-00-00 00:00:00
Document TitleMicrosoft Word - k5510_ii.doc
Document CreatorPSCRIPT.DRV Version 4.0
FCC ID Filing: CFSQ2260SN

Navigation menu