Adj Elation Sixbar 1000 Ip User Manual 033117 SIX BAR

Elation Sixbar 1000 Ip User Manual 033117 elation_sixbar_1000_IP_user_manual_033117 elation_sixbar_1000_IP_user_manual_033117 9778 ItemRelatedFiles

2017-11-09

User Manual: Adj Elation Sixbar 1000 Ip User Manual 033117 elation_sixbar_1000_IP_user_manual_033117 binaries

Open the PDF directly: View PDF PDF.
Page Count: 34

DownloadAdj Elation Sixbar 1000 Ip User Manual 033117 SIX BAR
Open PDF In BrowserView PDF
user manual	
  

	
  

E L A TI ON | SIXBAR 1000 IP™ | user manual

SIXBAR 1000 IP™

www.elationlighting.com
©2016 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without notice.
ELATION PROFESSIONAL logo and identifying product names and numbers herein
are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes
all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this
document may be trademarks or registered trademarks of their respective
companies and are hereby acknowledged. All non-ELATION brands and product
names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any
persons, and direct or indirect economic loss associated with the use or reliance of
any information contained within this document, and/or as a result of the improper,
unsafe, insufficient and negligent assembly, installation, rigging, and operation of
this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com

Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu

DOCUMENT

VERSION

Please check www.elationlighting.com for the latest revision/update of this manual.

DMX
Channel Modes

Date

Document
Version

Software
Version

6/26/16

1

≥V1.03

6 / 7 / 11 / 13 / 36 / 72 / 75 / 79

Initial release.

7/13/16

2

≥V1.03

6 / 7 / 11 / 13 / 36 / 72 / 75 / 79

Added updated photometric data.

3/31/17

2.1

N/C

N/C

Updated part # for Omega Bracket.

2

Notes

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

CONTENTS

General Information

4

Warranty

7

Safety Instructions

8

General Guidelines

9

Fixture Overview

10

Fixture Installation

11

Fixture Menu

13

DMX Channel Functions And Values

19

Cleaning and Maintenance

29

Technical Specifications

30

Optional Accessories

33

3

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! This fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
environments and has been designed with an enclosure that effectively protects
the ingress (entry) of external foreign objects such as dust and water. The
International Protection (IP) rating system is commonly expressed as "IP" (Ingress
Protection) followed by two numbers (i.e. IP65) where the numbers define the
degree of protection. The first digit (Foreign Bodies Protection) indicates the
extent of protection against particles entering the fixture and the second digit
(Water Protection) indicates the extent of protection against water entering the
fixture. An IP65 rated lighting fixture is one, which has been designed and tested
to protect against the ingress of dust (6) and high-pressure water jets from any
direction (5).

MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for marine
and/or coastal environment installations. Installing this fixture in a marine and/or
coastal environment may cause corrosion and/or excessive wear to the interior
and/or exterior components of the fixture. Damages and/or performance
issues resulting from installation in a marine and/or coastal environment will void
the manufactures warranty and will NOT be subject to any warranty claims
and/or repairs.
Ensure

ALL

connections

and

end

caps

are

properly

sealed

with

a

non-conductive dielectric grease (available at most electrical suppliers) to
prevent water ingress/condensation and/or corrosion.

OPTIONAL CORROSION-RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please consult your Elation Professional sales representative for details.

4

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS


powerCON TRUE1 Power Cable 6 ft. (1.8m)



Glare Shield



(3) Glare Shield Holding Screws



(2) Lens Filters



Manual & Warranty Card

CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322

Fax: 323-832-9142

E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30

Fax: +31 45 546 85 96

E-mail: support@elationlighting.eu

5

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx

to

validate

your

purchase.

All

returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.

IMPORTANT

NOTICE!

There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.

6

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

LIMITED WARRANTY
A.

Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to

be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B.

For warranty service, send the product only to the Elation Professional® factory. All shipping

charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C.

This warranty is void if the product serial number and/or labels are altered or removed; if the

product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D.

This is not a service contract, and this warranty does not include any maintenance, cleaning or

periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship.

The sole responsibility of Elation Professional® under

this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and PAR 200e identifying marks to that effect.
E.

Elation Professional® reserves the right to make changes in design and/or performance

improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F.

No warranty, whether expressed or implied, is given or made with respect to any accessory

supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G.

This warranty is the only written warranty applicable to Elation Professional® products and

supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

7

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

SAFETY INSTRUCTIONS
This fixture is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
manual. The manufacturer of this device will not accept responsibility for
damages resulting from the misuse of this fixture due to the disregard of the
information printed in this manual.
This device falls under PROTECTION CLASS 1. It’s essential this device be
grounded properly. Only qualified personnel should perform all electrical
connections.

UNPLUG POWER BEFORE SERVICING FIXTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!


For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.



Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from E P I L E P S Y should avoid looking directly into the light
source of this unit at all times.



The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.



Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.



Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.

8

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

GENERAL GUIDELINES


N E V E R

O P E N

T H I S

F I X T U R E

W H I L E

I N

U S E !



Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or
electrical short circuit.



During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.



Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.



The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.



DO NOT attempt installation and/or operation without knowledge how to do so.



DO NOT permit operation by persons who are not qualified to operate this type
of fixture. Most damages are the result of operations by nonprofessionals.



Consistent operational breaks may ensure the fixture will function properly for
many years to come.



DO NOT shake fixture, avoid brute force when installing and/or operating fixture.



Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.



Use the original packaging and materials to transport the fixture in for service.



DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.

9

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

FIXTURE OVERVIEW

SAFETY CABLE
RIGGING POINT
1.

Glare Shield Holding Screws (x3)

2.

IP Rated Power and DMX INPUTS

3.

IP Rated Power and DMX OUTPUTS

4.

LCD Menu Control Display, and MENU, UP, DOWN, ENTER Buttons

5.

Frost Filter Lens Release Button

10

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.

ELECTRICAL

CONNECTIONS

A qualified electrician should be used for all
electrical connections and/or installations.

CAUTIONS


For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.



Ambient operating temperature range for this fixture is 5° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.



Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.



Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.



Never stand directly below the device when mounting, removing or servicing.



Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or
electrical short circuit.

POWER LINKING
Max number of units that can be power linked is 6 units @110V and 14 units @240V.
CLAMP MOUNTING
The fixture provides an integrated mounting dual bracket / yoke. Make sure to
secure an appropriately rated clamp to the mounting bracket using M10 screws
when mounting this fixture to truss.
11

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these qualifications,
do not attempt the installation yourself. Improper installation can result in bodily
injury. Fixture is fully operational in the specific mounting positions as illustrated
below.

SAFETY CABLES
ALWAYS USE A SAFETY CABLE (NOT INCLUDED) WHENEVER INSTALLING THIS FIXTURE IN A
SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.

12

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will detail
the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on back of the fixture allows you to
access the main menu and make all necessary adjustments to the fixture. During
normal operation, pressing MODE button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE button.

INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:

Update
Wait...

ELATION
Six Bar

1000IP
V1.03
Fixture Software Version
(Greater than or equal to)

13

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
LCD CONTROL PANEL LOCKOUT
When AutoLock menu is set to ON, the LCD display backlight will turn OFF after 30
seconds and the Control Panel will lock and the display will show LOCKED*****.
Press and hold the MODE button for 5 seconds to unlock.
When AutoLock menu is set to ON1, the LCD display backlight will turn OFF after 30
seconds and the Control Panel will lock and the display will show LOCKED*****.
To unlock the Control Panel follow these steps:
1. When locked, the display will show: LOCKED*****
2. Press UP, then the display will change to: LOCKED**** (one * disappears)
3. Press DOWN, then the display will change to: LOCKED*** (two * disappear)
4. Press UP, then the display will change to: LOCKED** (three * disappear)
5. Press DOWN, then the display will change to: LOCKED* (4 * disappear)
6. Press ENTER, then the display will change to LOCKED and then become unlocked.
ELATION© SIXBAR 1000 IP™
SYSTEM MENU
MENU

DMX MODE
ADDR:xxx
CH:xx
SLAVE
MODE

Specifications are subject to change without any prior written notice.
OPTIONS / VALUES (Default Settings BOLD)
DESCRIPTION
ADDR:001 - 512
CH:06, 07, 11, 13, 36, 72, 75, 79

Set DMX Address.
Set DMX Channel Mode.
Set unit to Slave Mode.

AUTO RUN
FQN:xx

FQN:01-99

Set the number of times each internal macro will
repeat before moving to the next macro.

01.STATIC
15.FLOW1

01-15

Select Internal Program Macro.
See PROGRAM MACRO MENU for more details.

DimCurve

Standard, Stage, TV, Architec, Theatre

Set desired Dimming Curve.

ON, OFF

Set starting LED.
See FLIP Section for more details.

NO DMX

Hold, Blackout, Program

Define how fixture reacts when NO DMX signal present.

Manual

R000-255
W000-255
STR:00-99

Macros

00-63

Select Internal Color Macro.
See COLOR MACRO MENU for more details.

OFF (default), ON, ON1

Set LCD Control Panel Lockout Function.

000

Fixture Internal Temperature (Celsius).

Flip

AutoLock
Temp.

G000-255
A000-255

B000-255
U000-255

Set RGBWAU and Strobe Values manually.

14

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
PRGRAM MACRO MENU
MACRO

Features are subject to change without any prior written notice.
OPTIONS / VALUES
DESCRIPTION

01.STATIC

CL:RGB

02.DREAM

Speed01-99 Flash00-99

03.METOR

Speed01-99 Flash00-99

04.FADE

Speed01-99 Flash00-99

05.CHANG

Speed01-99 Flash00-99

06.FLOW1

Speed01-99 Flash00-99

07.FLOW2

Speed01-99 Flash00-99

08.FLOW3

Speed01-99 Flash00-99

09.FLOW4

Speed01-99 Flash00-99

10.FLOW5

Speed01-99 Flash00-99

11.FLOW6

Speed01-99 Flash00-99

12.FLOW7

Speed01-99 Flash00-99

13.FLOW8

Speed01-99 Flash00-99
C1:RGB
C2:RGB

14.FLOW 9

Speed01-99 Flash00-99
C1:RGB
C2:RGB

15.FLOW 10

Speed01-99 Flash00-99

F00-99

15

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
DimCurve
Select desired DIMMER MODE (Standard, Stage, TV, Architec, Theatre).

Flip
Select the desired starting LED and chase direction from one of the following modes below
via UP/DOWN buttons and then press ENTER to confirm. (Default = STANDARD)

FLIP = OFF

FLIP = ON

16

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
COLOR MACRO
MACRO #
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

MENU

Actual colors may vary and subject to change without notice.
COLOR MACRO
DMX VALUES
0-3
OFF
4-7
RED

GREEN
BLUE
WHITE
AMBER
UV
RED + GREEN
RED + BLUE
RED + WHITE
RED + AMBER
RED + UV
GREEN + BLUE
GREEN + WHITE
GREEN + AMBER
GREEN + UV
BLUE + WHITE
BLUE + AMBER
BLUE + UV
WHITE + AMBER
WHITE + UV
AMBER + UV
RED + GREEN + BLUE
RED + GREEN + WHITE
RED + GREEN + AMBER
RED + GREEN + UV
RED + BLUE + WHITE
RED + BLUE + AMBER
RED + BLUE + UV
RED + WHITE + AMBER
RED + WHITE + UV
RED + AMBER + UV
GREEN + BLUE + WHITE

8-11
12-15
16-19
20-23
24-27
28-31
32-35
36-39
40-43
44-47
48-51
52-55
56-59
60-63
64-67
68-71
72-75
76-79
80-83
84-87
88-91
92-95
96-99
100-103
104-107
108-111
112-115
116-119
120-123
124-127
128-131

17

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
COLOR MACRO
MACRO #
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

MENU

Actual colors may vary and subject to change without notice.
COLOR MACRO

GREEN + BLUE + AMBER
GREEN + BLUE + UV
GREEN + WHITE + AMBER
GREEN + WHITE + UV
GREEN + AMBER + UV
BLUE + WHITE + AMBER
BLUE + WHITE + UV
BLUE + AMBER + UV
WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE
RED + GREEN + BLUE + WHITE
RED + GREEN + BLUE + UV
RED + GREEN + WHITE + AMBER
RED + GREEN + WHITE + UV
RED + GREEN + AMBER + UV
RED + BLUE + WHITE + AMBER
RED + BLUE + WHITE + UV
RED + BLUE + AMBER + UV
RED + WHITE + AMBER + UV
GREEN + BLUE + WHITE + AMBER
GREEN + BLUE + WHITE + UV
GREEN + BLUE + AMBER + UV
GREEN + WHITE + AMBER + UV
BLUE + WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE + AMBER
RED + GREEN + BLUE + WHITE + UV
RED + GREEN + BLUE +AMBER + UV
RED + GREEN + WHITE + AMBER + UV
RED + BLUE + WHITE + AMBER + UV
GREEN + BLUE + WHITE + AMBER + UV
RED + GREEN + BLUE + WHITE + AMBER+ UV

18

DMX VALUES
132-135
136-139
140-143
144-147
148-151
152-155
156-159
160-163
164-167
168-171
172-175
176-179
180-183
184-187
188-191
192-195
196-199
200-203
204-207
208-211
212-215
216-219
220-223
224-227
228-231
232-235
236-239
240-243
244-247
248-251
252-255

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

DMX CHANNEL FUNCTIONS AND VALUES
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

36CH

72CH

75CH

79CH

VALUE

FUNCTION
RED LED - All LEDS [1-12]

1
2
3
4
5
6
7
8

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [1-12]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [1-12]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [1-12]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [1-12]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [1-12]

0-255

UV (0-Black - 255-100%)
RED LED - All LEDS [1-2]

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [1-2]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [1-2]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [1-2]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [1-2]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [1-2]

0-255

UV (0-Black - 255-100%)
RED LED - All LEDS [3-4]

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [3-4]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [3-4]

9

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [3-4]

10
11
12

19

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [3-4]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [3-4]

0-255

UV (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

VALUE

FUNCTION
RED LED - All LEDS [5-6]

13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

20

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [5-6]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [5-6]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [5-6]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [5-6]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [5-6]

0-255

UV (0-Black - 255-100%)
RED LED - All LEDS [7-8]

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [7-8]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [7-8]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [7-8]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [7-8]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [7-8]

0-255

UV (0-Black - 255-100%)
RED LED - All LEDS [9-10]

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [9-10]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [9-10]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [9-10]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [9-10]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [9-10]

0-255

UV (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

VALUE

FUNCTION
RED LED - All LEDS [11-12]

31
32
33
34
35
36
1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

9

9

9

10

10

10

11

11

11

21

0-255

Red (0-Black - 255-100%)
GREEN LED - All LEDs [11-12]

0-255

Green (0-Black - 255-100%)
BLUE LED - All LEDs [11-12]

0-255

Blue (0-Black - 255-100%)
WHITE LED - All LEDs [11-12]

0-255

White (0-Black - 255-100%)
AMBER LED - All LEDs [11-12]

0-255

Amber (0-Black - 255-100%)
UV LED - All LEDs [11-12]

0-255

UV (0-Black - 255-100%)
RED LED - LED [1]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [1]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [1]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [1]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [1]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [1]

0-255

UV (0-Black - 255-100%)
RED LED - LED [2]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [2]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [2]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [2]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [2]

0-255

Amber (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

12

12

12

13

13

13

14

14

14

15

15

15

16

16

16

17

17

17

18

18

18

19

19

19

20

20

20

21

21

21

22

22

22

23

23

23

24

24

24

25

25

25

26

26

26

27

27

27

28

28

28

29

29

29

30

30

30

22

VALUE

FUNCTION
UV LED - LED [2]

0-255

UV (0-Black - 255-100%)
RED LED - LED [3]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [3]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [3]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [3]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [3]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [3]

0-255

UV (0-Black - 255-100%)
RED LED - LED [4]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [4]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [4]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [4]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [4]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [4]

0-255

UV (0-Black - 255-100%)
RED LED - LED [5]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [5]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [5]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [5]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [5]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [5]

0-255

UV (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

31

31

31

32

32

32

33

33

33

34

34

34

35

35

35

36

36

36

37

37

37

38

38

38

39

39

39

40

40

40

41

41

41

42

42

42

43

43

43

44

44

44

45

45

45

46

46

46

47

47

47

48

48

48

23

VALUE

FUNCTION
RED LED - LED [6]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [6]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [6]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [6]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [6]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [6]

0-255

UV (0-Black - 255-100%)
RED LED - LED [7]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [7]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [7]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [7]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [7]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [7]

0-255

UV (0-Black - 255-100%)
RED LED - LED [8]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [8]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [8]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [8]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [8]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [8]

0-255

UV (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

49

49

49

50

50

50

51

51

51

52

52

52

53

53

53

54

54

54

55

55

55

56

56

56

57

57

57

58

58

58

59

59

59

60

60

60

61

61

61

62

62

62

63

63

63

64

64

64

65

65

65

66

66

66

24

VALUE

FUNCTION
RED LED - LED [9]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [9]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [9]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [9]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [9]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [9]

0-255

UV (0-Black - 255-100%)
RED LED - LED [10]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [10]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [10]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [10]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [10]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [10]

0-255

UV (0-Black - 255-100%)
RED LED - LED [11]

0-255

Red (0-Black - 255-100%)
GREEN LED - LED [11]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [11]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [11]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [11]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [11]

0-255

UV (0-Black - 255-100%)

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

7

11CH

7

13CH

7

36CH

72CH

75CH

79CH

67

67

67

68

68

68

69

69

69

70

70

70

71

71

71

72

72

72

73

73

FUNCTION

VALUE

RED LED - LED [12]
0-255

Red (0-Black - 255-100%)
GREEN LED - LED [12]

0-255

Green (0-Black - 255-100%)
BLUE LED - LED [12]

0-255

Blue (0-Black - 255-100%)
WHITE LED - LED [12]

0-255

White (0-Black - 255-100%)
AMBER LED - LED [12]

0-255

Amber (0-Black - 255-100%)
UV LED - LED [12]

0-255

UV (0-Black - 255-100%)
MASTER DIMMER

0-255

0 to 100%
STROBE

8

8

74

74

25

0-31

NO Function

32-63

LEDs ON

64-95

Strobe Effect SLOW to FAST

96-127

LEDs ON

128-159

Pulse Effect In Sequence SLOW to FAST

160-191

LEDs ON

192-223

Random Strobe Effect SLOW to FAST

224-255

LEDs ON

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Features are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

VALUE

FUNCTION
COLOR MACROS

9

75

26

0-3

NO Function

4-7

Color Macro 01

8-11

Color Macro 02

12-15

Color Macro 03

16-19

Color Macro 04

20-23

Color Macro 05

24-27

Color Macro 06

28-31

Color Macro 07

32-35

Color Macro 08

36-39

Color Macro 09

40-43

Color Macro 10

44-47

Color Macro 11

48-51

Color Macro 12

52-55

Color Macro 13

56-59

Color Macro 14

60-63

Color Macro 15

64-67

Color Macro 16

68-71

Color Macro 17

72-75

Color Macro 18

76-79

Color Macro 19

80-83

Color Macro 20

84-87

Color Macro 21

88-91

Color Macro 22

92-95

Color Macro 23

96-99

Color Macro 24

100-103

Color Macro 25

104-107

Color Macro 26

108-111

Color Macro 27

112-115

Color Macro 28

116-119

Color Macro 29

120-123

Color Macro 30

124-127

Color Macro 31

128-131

Color Macro 32

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

9

75CH

79CH

75

27

VALUE

FUNCTION

132-135

Color Macro 33

136-139

Color Macro 34

140-143

Color Macro 35

144-1147

Color Macro 36

148-151

Color Macro 37

152-155

Color Macro 38

156-159

Color Macro 39

160-163

Color Macro 40

164-167

Color Macro 41

168-171

Color Macro 42

172-175

Color Macro 43

176-179

Color Macro 44

180-183

Color Macro 45

184-187

Color Macro 46

188-191

Color Macro 47

192-195

Color Macro 48

196-199

Color Macro 49

200-203

Color Macro 50

204-207

Color Macro 51

208-211

Color Macro 52

212-215

Color Macro 53

216-219

Color Macro 54

220-223

Color Macro 55

224-227

Color Macro 56

228-231

Color Macro 57

232-235

Color Macro 58

236-239

Color Macro 59

240-243

Color Macro 60

244-247

Color Macro 61

248-251

Color Macro 62

252-255

Color Macro 63

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
ELATION© SIXBAR 1000 IP™
DMX Channel Values / Functions Version 1 (79 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LEDs depends on the Pixel Flip setting.
DMX CHANNEL MODE
6CH

7CH

11CH

13CH

36CH

72CH

75CH

79CH

FUNCTION

VALUE

PROGRAM MACROS

9

10

76

0-10

NO Function

11-26

Program 01 - DREAM

27-43

Program 02 - METEOR

44-60

Program 03 - FADE

61-76

Program 04 - CHANGE

77-93

Program 05 - FLOW 1

94-110

Program 06 - FLOW 2

111-126

Program 07 - FLOW 3

127-143

Program 08 - FLOW 4

144-160

Program 09 - FLOW 5

161-176

Program 10 - FLOW 6

177-193

Program 11 - FLOW 7

194-210

Program 12 - FLOW 8

211-226

Program 13 - FLOW 9

227-255
10

11

77

11

12

78

NO Function
PROGRAM SPEED

0-255

Program Speed SLOW to FAST

0-255

Program Fade FAST to SLOW

PROGRAM FADE
DIMMING CURVE MODES

13

75

79

28

0-20

STANDARD

21-40

STAGE

41-60

TV

61-80

ARCHITECTURAL

81-100

THEATRE

101-255

Default to Unit Setting

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

CLEANING AND MAINTENANCE
C

A

U

T

I

O

N

Disconnect power before cleaning or maintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output,
and an extended life. The frequency of cleaning depends on the environment in
which the fixture operates: damp, smoky or particularly dirty environments can
cause greater accumulation of dirt on the fixture’s optics.


Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation.



Never use alcohol, solvents, or ammonia based cleaners.

MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service
issues to an authorized Elation service technician. Should you need any spare parts,
please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:


A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.



Be sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury as larger parts
could fall.



Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust to enter into the fixture. Damaged rigging points or unsecured
rigging could cause the fixture to fall and seriously injure a person(s).



Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
29

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

TECHNICAL SPECIFICATIONS
SOURCE
(12) 12W 6-in-1 RGBAW+UV LEDs
100,000 Hour Average LED Life*
*May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

EFFECTS
Pixel Control
Strobe and Chase Effects
Selectable Dimming Curves
COLOR
RGBAW+UV
CONTROL / CONNECTIONS
(8) DMX Channel Modes (6 / 7 / 11 / 13 / 36 / 72 / 75 / 79)
RDM (Remote Device Management)
4 Touch Button Control Panel and LCD Menu Display
5pin IP DMX In/Out
powerCON TRUE1 In/Out
SIZE / WEIGHT
Length: 33.9” (860mm)
Width: 5.6” (142mm)
Vertical Height: 4.9” (125mm)
Weight: 19.0 lbs. (8.6 kg)
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz
145W Max Power Consumption
5F to 113°F (-15°C to 45°C)
UV Wavelength: 395nm
APPROVALS / RATINGS
CE | RoHs | IP65**
**Optional Corrosion-Resistant Coating may be available for this fixture. Please consult an Elation sales representative for details.
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

30

SIXBAR 1000 IP™ User Manual

www.elationlighting.com
PHOTOMETRIC DATA
1m
3.3 ft
25° Beam
Diameter
RED LEDs
GREEN
LEDs
BLUE LEDs
WHITE LEDs
AMBER
LEDs
UV LEDs
FULL ON

2m

6.6 ft

3m

9.8 ft

4m

13.1 ft

5m

16.4 ft

0.45

1.5

0.88

2.9

1.33

4.4

1.77

5.8

2.21

7.3

lux
1,253
3,267
469
2,813
1,286
50
7,149

fc
116
304
44
261
119
5
664

lux
542
1,416
211
1,216
532
24
2,910

fc
50
132
20
113
49
2
270

lux
283
726
108
621
271
13
1,481

fc
26
67
10
58
25
1
138

lux
172
429
65
372
153
10
880

fc
16
40
6
35
14
1
82

lux
119
275
45
242
101
7
603

fc
11
26
4
22
9
1
56

	
   9.8 ft

	
   	
   4 m

PHOTOMETRIC DATA (with DIFFUSION FILTER)
DIFFUSSION	
  FILTER	
  
35° Beam
Diameter
RED LEDs
GREEN
LEDs
BLUE LEDs
WHITE LEDs
AMBER
LEDs
UV LEDs
FULL ON

1m

	
   3.3 ft

	
   	
   2 m

	
   6.6 ft

	
   	
   3 m

	
  13.1 ft

	
   	
   5 m

	
  16.4 ft

0.63

2.1

1.27

4.2

1.9

6.2

2.52

8.3

3.16

10.4

lux
1,157
2,492
477
2,701
1,199
75
6,413

fc
107
232
44
251
111
7
596

lux
503
1,041
202
1,135
510
36
2,608

fc
47
97
19
105
47
3
242

lux
260
528
103
576
259
22
1,287

fc
24
49
10
54
24
2
120

lux
161
316
65
346
155
16
767

fc
15
29
6
32
14
1
71

lux
109
211
45
231
104
13
508

fc
10
20
4
21
10
1
47

	
   9.8 ft

	
   	
   4 m

PHOTOMETRIC DATA (with FROST FILTER)
FROST	
  FILTER	
  
45° Beam
Diameter
RED LEDs
GREEN
LEDs
BLUE LEDs
WHITE LEDs
AMBER
LEDs
UV LEDs
FULL ON

1m

	
   3.3 ft

	
   	
   2 m

	
   6.6 ft

	
   	
   3 m

	
  13.1 ft

	
   	
   5 m

0.83

2.7

1.66

5.4

2.49

8.2

3.31

10.9

4.14

13.6

lux
689
2,015
358
1,809
858
47
4,377

fc
64
187
33
168
80
4
407

lux
258
722
126
631
314
21
1,563

fc
24
67
12
59
29
2
145

lux
127
358
66
313
150
12
760

fc
12
33
6
29
14
1
71

lux
79
222
41
196
98
8
465

fc
7
21
4
18
9
1
43

lux
52
147
28
129
65
7
307

fc
5
14
3
12
6
1
29

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

31

SIXBAR 1000 IP™ User Manual

	
  16.4 ft

www.elationlighting.com
DIMENSIONAL DRAWINGS

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

32

SIXBAR 1000 IP™ User Manual

www.elationlighting.com

OPTIONAL ACCESSORIES
ORDER CODE

ITEM

TRIGGER CLAMP

Heavy Duty Wrap Around Hook Style Clamp

EWD001

EWDMX IP Wireless IP65 DMX Transceiver

8050000053

Omega Bracket (single)

NEU088

3' (1m) powerCON TRUE1 Power Link Cable
Additional Cable Lengths Available

33

SIXBAR 1000 IP™ User Manual



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Create Date                     : 2017:03:31 22:11:49Z
Creator Tool                    : Word
Modify Date                     : 2017:03:31 15:12:42-07:00
Metadata Date                   : 2017:03:31 15:12:42-07:00
Producer                        : Adobe Mac PDF Plug-in
Format                          : application/pdf
Title                           : ELATION SIX BAR 1000 IP - USER MANUAL 033117
Creator                         : CMG
Document ID                     : uuid:24708757-c895-6745-9949-5bd825bc6f0e
Instance ID                     : uuid:49d15355-2a36-c840-8e6d-ccb497bb32fd
Page Count                      : 34
Author                          : CMG
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools