ADTRAN 1287562G1 TOTAL ACCESS 324RG User Manual

Adtran TOTAL ACCESS 324RG

HDC1287562G1_User Manual

jobAid 1DESCRIPTIONThe Total Access 324RG Indoor 2 POTS + 4GigE (P/N 1287562G1) Home Gateway Optical Network Termination (ONT) provides Triple-Play services to a customer premises. The following is an illustration of the Home Gateway ONT.FEATURESThe Indoor 2 POTS + 4GigE has the following features:Two POTS Interfaces Four Ethernet fiber interfaces with 1.244 Gigabits per second Upstream and 2.488 Gigabits per second downstreamOne Optical InterfaceAC Power AdapterUSB InterfaceVoice ProcessingPOTS uses in-band signaling tones and currents to determine call status (for example, call request). Because POTS allows for the transfer of audio signals below 3.3 kHz, POTS systems are also used for modems that allow data transmission (referred to as dial up connections). Ethernet InterfaceThe Home Gateway ONT supports data service through four 10/100/1000Base-T Ethernet interfaces via an RJ-45-style connector. Reset ButtonWPS DataEncryptionButtonUSB InterfaceOpticalInterfacePowerConnectionPower On/OEthernetInterfacesPOTSInterfacesWLAN ButtonTotal Access 324RGIndoor 2 POTS + 4GigEHome Gateway ONTPowerThe power feed is 12 VDC. INSTALLATIONBefore installing the Home Gateway ONT, inspect it for damage. If damage has occurred during shipping, file a claim with the carrier and then contact ADTRAN. For more information, refer to the warranty.Installation GuidelinesThe following are guidelines for this installation.WARNING!Read all warnings and cautions before installing or servicing theHome Gateway ONT.Resetting the ONTA reset button is available if the Home Gateway ONT needs to be rebooted. To reset the Home Gateway ONT, insert a small pin into the RESET opening and hole the button down for 5 seconds or longer. WARNING!All settings will return to Factory Defaults: Registrationprovisioning will be lost.Resetting the WLANThe Home Gateway ONT is equipped with a wireless local area network (WLAN) reset button. Refer to the illustration at the top of the first column for the button’s location. This is the WiFi link to other Internet devices. To reset the WLAN, press the WLAN button once.WPS SecurityThe Home Gateway ONT is equipped with a WiFi Protected Setup (WPS) security button. This button is used to secure a wireless home network. However, there are security issues with this type of connection and ADTRAN does not recommend using this feature.Product P/N: 1287562G1Issue Date: April 2014Document P/N: 61287562G1-22ADocumentation for ADTRAN Carrier Networks products is available for viewing and download directly from the ADTRAN Support Community website. Go to: https://supportforums.adtran.com/welcomeRegistration is required.ADTRAN offers training courses on our products, including customized training and courses taught at our facilities or at customer sites.For inquiries, go to: http://adtran.com/trainingThe following documents provide additional information for this product:Total Access 5000 GPON OLT User Interface GuideTotal Access 5000 Fiber to the Premises Deployment GuideTotal Access 5000/5006 Engineering and Ordering GuideDRAFT
261287562G1-22A1. Remove the POTS cable supplied with the Home Gateway ONT and connect one end to the Home Gateway ONT and the other end to a standard telephone base.2. If a POTS cable is not available, select a standard telephone twisted pair cable of appropriate length and trim the insulation back approximately 1/2 inch on each end.3. Refer to the illustration below and connect the twisted-pair Tip (green) and Ring (Red) to the RJ-11 connectors using an RJ-11 crimper.4. Connect one end of the POTS cable to the Home Gateway ONT and the other end to a standard telephone connection.Step 3: Connect Ethernet The Home Gateway ONT supports four Gigabit (10/100/1000Base-T) connections. To install Ethernet to the Home Gateway ONT, refer to the illustration on the first page and complete the following steps:1. Remove the Ethernet cable supplied with the Home Gate-way ONT and attach one end to the LAN1 connection on the rear of the Home Gateway ONT and the other end to the incoming Ethernet device.2. If an Ethernet cable is not available, obtain a CAT5 or 6 cable of appropriate length and trim the insulation back approximately 1/2 inch on both ends.3. Connect the wires per to an RJ-45 connector using the table below.4. Crimp the connector using an RJ-45 Crimper.5. Connect one end to the appropriate LAN1 connection on the rear of the Home Gateway ONT and the other end to the incoming Ethernet device.6. Repeat these steps as necessary for each additional Ethernet connection required.Ethernet RJ-45 Pin-outPin Name Description ColorCode1 TRD0+ Transmit/ReceivePositive White/Orange2TRD0‐Transmit/ReceiveNegative Orange3 TRD1+ Transmit/ReceivePositive White/Green4 TRD2+ Transmit/ReceivePositive Blue5TRD2‐Transmit/ReceiveNegative White/Blue6TRD1‐Transmit/ReceiveNegative Green7 TRD3+ Transmit/ReceivePositive White/Brown8TRD3‐Transmit/ReceiveNegative Brown1 2 3 41 = Not Connected2 = Tip3 = Ring4 = Not connectedPOTS Pin-OutsInstallation OverviewTo install the Home Gateway ONT, complete the following steps:Step 1: Install Home Gateway ONT Step 2: Connect POTSStep 3: Connect EthernetStep 4: Connect FiberStep 5: Connect PowerStep 6: Connect USBRequired toolsStandard technician tools and those listed below are required for installing the Home Gateway ONT:3/32 inch screw driver for connecting Home Gateway ONT powerRJ-45/RJ-11 crimperA telephony/data communication test setPON power meter with wavelength filteringFiberscope or videoscopeTwo #8 Pan Head screws (1 inch or greater in length)Assorted tie wraps for securing cabling and wiringFor fiber optic connections, the following are required:Fiber optical fusion splice toolsODC Fiber cleaning toolSC Fiber connectorInstallation StepsTo install the Home Gateway ONT, refer to the illustration on the first page and complete the following steps.Step 1: Install the Home Gateway ONTThere are two options when installing the Home Gateway ONT: Desk Top and Wall Mount. Both are described below.Desk Top InstallationThe Home Gateway ONT can sit on a desktop or be wall mounted. With a desk mount, ensure the Home Gateway ONT is not located in direct sunlight and is not located next to any thermal obstructions. Wall Mount InstallationTo wall mount the Home Gateway ONT, perform the following steps:1. Decide on a location for the Home Gateway ONT. Included with the Home Gateway ONT is a 12 V Power Adaptor with a 4-foot power cord. The installation location should be within 4 feet of a wall outlet.2. Remove the Mounting Bracket from the bottom of the Home Gateway ONT.3. Use the keyhole slots on the back of the Mounting Bracket as a template and attach it to drywall using the appropriate anchors.4. Reattach the Home Gateway ONT to the Mounting Bracket.Step 2: Connect POTSTo connect POTS, refer to the illustration on the first page and perform the following steps:DRAFT
61287562G1-22A 3Step 4: Connect FiberCAUTIONCLASER RADIATION1310 nm to 1600 nmDo not view directly with optical instruments.This product contains a Class 1M Laser module that complies with 21 CFR1040.10 and 1040.11 and IEC 60825-1 and -2.Fiber is installed using an SC connecter attached to the OPTICAL Interface on the rear of the Home Gateway ONT. Refer to the illustration on the first page and complete the following steps to connect fiber:1. Remove the protective cover from the OPTICAL Interface.NOTEThe protective cover should always be inserted in the opticalinterface when the Fiber connection is not in use. This will helpprotect the optical components.2. Clean the ends of the SC connector and the surface of the OPTICAL Interface using appropriate fiber cleaning methods.3. Connect the incoming fiber cable to the SC connection.4. Route the fiber cable so that it is protected from accidental harm.Step 5: Connect PowerTo connect power to the Home Gateway ONT, refer to the illus-tration on the first page and complete the following steps:1. Plug the supplied 12V AC/DC Power Converter into the PWR connection on the rear of the Home Gateway ONT.2. Connect the power plug to a standard 120V AC outlet. 3. Verify the power is on by checking the PWR LED on the Home Gateway ONT. The LED should be green indicating local power is on and voltage is good.ON/OFF ButtonAn On/Off button is located on the far-right side of the rear of the Home Gateway ONT. User functionality is limited to this button.NOTEIf a Battery Backup (BBU) is being used and is disconnected, theHome Gateway ONT is not protected from power outages, andwill send a “Battery Missing” alarm to the OLT.Step 6: Connect USBThe Home Gateway ONT is equipped with a USB port. Refer to the illustration on the first page for the location of this connection.LED STATUSThe LEDs are located beneath the plastic housing and are only visible after power has been applied. The following table provides the LED status during normal operations.*ONU. An Optical Network Unit (ONU) is a device that transforms incoming optical signals into electronic signals at a customer’s premises. Label Status IndicationPWR OffGreenONT power is OffONT power OnLINK 2OffGreenGreen Flashing ONT is not active (not Ranged)ONT is active (Ranged)ONT is activating (Ranging in progress)AUTH 2OffGreenGreen Flashing ONU* is NOT authorizedONU is authorizedONU is registeringLAN1 -4  2OffGreenGreen Flashing Link is downLAN Port is upLAN Port is actively transmit-ting and receivingTEL1 - 22OffGreenGreen Flashing ONT is not registeredONT is registered and on hookOff hook or call in progressINTER-NET2OffGreenGreen Flashing WAN not configuredInternet is connectedInternet is connectingWPS 22OffGreen Yellow FlashingRed FlashingWPS is disabledWPS status is “Successful”WPS status is “in Progress”WPS is experiencing errorsWLAN 2OffGreenGreen Flashing Error/WLAN is not connectedWLAN is connectedWLAN receiving/transmitting dataUSB 2OffGreenGreen Flashing No power or USP not con-nectedUSP connectedUSP receiving/transmitting dataDRAFT
TROUBLESHOOTINGThe following table can be used for troubleshooting purposes:SPECIFICATIONSRefer to the following for a list of all specifications for the Indoor Home Gateway ONT.ElectricaloVoltage: 12 Volts typicaloMinimum Voltage: 10 VoltsoMaximum Voltage: 13.9 VoltsoPower Consumption: Typical 13.9 wattsPhysicalo10.0 inches wide (19.5 centimeters)o5.9 inches deep ((18.8 centimeters)o 1.5 inches high (3.3 centimeters no bracket, 5.1 with bracket)oWeight: 2 pounds (0.9 kilograms)EnvironmentaloOperational Temperature: 32°F to +113°F (0°C to +50°C)oStorage Temperature: –40°F to 185°F (–20°C to +50°C)oRelative Humidity: 90%, noncondensingProblem Possible SolutionThe Power LED is Off Verify that the power adapter is plugged into a live AC outlet.Check that he ON/OFF button is pressed in.Check the power cable for shorts or breaks.Disconnect the power input con-nector at the ONT and use a volt-meter to verify that the proper voltage level is present on the 12 V pin (power and power return) from the power adapter.The LINK LED is Off Check that the optical fiber is connected correctly.Check the optical connector for dirt or damage.LINK LED is ON, but INTERNET LED is OffThe signal sent by the service provider is not being received. Contact the service provider for assistance.The LAN LED is Off Check that the Ethernet cable is connected correctly.Check that the network adaptor works normally. Refer to the doc-umentation that accompanied the network adapter as needed.OpticaloTX min power: 0.5 dBmoTX max power: 5.0 dBmoRSSI max sensitivity: -27 dBmoRX overload: -8 dBmoTX wavelength: 1310 nm typicaloRX wavelength: 1490 nm typicalMAINTENANCEThe Indoor 2 POTS + 4GigE does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the warranty for further information. Field support for software is provided through upgrade facilities.SAFETY AND REGULATORY COMPLIANCERefer to the Total Access 324RG Indoor 2 POTS + 4GigE Safety and Regulatory Compliance Notice (61287562G1-17) for detailed safety and regulatory information.DRAFT61287562G1-22A 4
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help.Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peutfonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que lapuissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.MPE RemindingTo satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moinde 20 cm. Installer les antennes de facon à ce que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l' antenne. La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d'au moins 20 cm des personnes pendant son functionnement.Region SelectionLimited by local law regulations, version for North America does not have region selection option.CAUTION!SUBJECT TO ELECTROSTATIC DAMAGEOR DECREASE IN RELIABILITYHANDLING PRECAUTIONS REQUIREDWarranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online at www.adtran.com/warranty.©2014 ADTRAN, Inc. All Rights Reserved. ADTRAN CUSTOMER CARE:From within the U.S.     1.800.726.8663From outside the U.S. +1 256.963.8716PRICING AND AVAILABILITY  1.800.827.0807*61287562G1-22A*