ADTRAN 424RG50X Wireless Mini PCI User Manual

Adtran Wireless Mini PCI

User Manual

jobAid 1DESCRIPTIONThe ADTRAN 2 POTS/4GigE with 2.4+5.0 Gig WiFi is an Optical Network Unit (424RG ONU) that converts signals being transmitted on optical fiber into electrical signals at a customer location. The illustration at the left displays the front and rear of the 424RG ONU. FEATURESThe 424RG ONU supports the following features:■Two POTS (PHONE) Ports■Four Ethernet Ports■2.4 GHz and 5.0 GHz WiFi■12 VDC Power Adapter■USB Port■UPS Connector■Reset ButtonResetting the ONTWARNING!All settings will return to Factory Defaults; registration provisioning will be lost.A reset button is available if the 424RG ONU needs to be rebooted. The Reset button is located just below the USB port on the rear of the 424RG ONU. To reset the 424RG ONU, press the RESET button for 5 seconds or longer. Voice ProcessingPOTS uses in-band signaling tones and currents to determine call status (for example, call request). Because POTS allows for the transfer of audio signals below 3.3 kHz, POTS systems are also used for modems that allow data transmission (referred to as dial up connections). Ethernet InterfaceThe 424RG ONU supports data service through four 10/100/1000Base-T Ethernet interfaces via RJ-45 connectors. PowerPower is provided by a 12 VDC Power Adapter that is included with the 424RG ONU. The Power Adapter operates from a main power source input of 100 to 240 VAC, 50/60 Hz, with a nominal output of 12 VDC. The total power consumption with WiFi enabled, 4 Ethernet Ports running and both POTS lines off-hook is approximately 22.0 Watts. A connection for an optional un-interruptible power supply (UPS) is also provided.UPSThe 424RG ONU provides an optional connection for an UPS. An UPS is a battery backup system designed to continue providing power when the primary power source is lost. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises and keeps the battery charged.CLEI: BVMFG00A_ _Product P/N: 1287781F2Issue Date: July 2016Document P/N: 61287781F2-22ADocumentation for ADTRAN® Carrier Networks products is available for viewing and download directly from the ADTRAN Support Community website. Go to: https://supportforums.adtran.com/welcomeRegistration is required.ADTRAN offers training courses on our products, including customized training and courses taught at our facilities or at customer sites.For inquiries, go to: http://adtran.com/trainingThe following related online documents and resources provide additional information for this product:Total Access 5000 GPON OLT User Interface GuideTotal Access 5000 Series CLI DictionaryTotal Access 5000/5006 Engineering GuideTotal Access 5000 Series Fiber to the Premises Deployment GuideADTRAN 400 Series Residential Gateway ONT Basic Configuration GuideADTRAN 424RG2 POTS/4GigE with 2.4+5.0 Gig WiFiOptical Network UnitWPSSRESETUSBGE 4GE 3GE 2GE 1PHONE 1PHONE 2UPS12V12342.45.012Front Rear
261287781F2-22AInstallation StepsNOTICEThe 424RG ONU must sit upright using the stand provided. DO NOTlay the ONT flat as it may overheat.To install the 424RG ONU, refer to the figures on the first page and complete the following steps.Step 1: Install the Base and Connect FiberEnsure the 424RG ONU is not located in direct sunlight and is not located next to any thermal obstructions. To attach the 424RG ONU to the base, refer to Figure 1 and complete the following steps:1. Remove the two screws from the base of the 424RG ONU.2. Position the 424RG ONU on the base.3. Using the two screw provided, secure the base to the 424RG ONU.4. Thread the fiber cable through the opening in the base. If there is excess fiber, carefully wrap it around the Fiber Tray.5. Remove the plug from the SC/APC Connector and insert the fiber cable. Retain this plug and insert it in the fiber connection when the fiber cable is not connected. This will protect the optical portion of the connection.Figure 2 illustrates the 424RG ONU after the base has been attached.Figure 1. Attach 424RG ONU to Base and Connect FiberFigure 2. 424RG ONU with Base AttachedScrewFiberTraySC/APCConnectorFiberOpeningScrew12342.45.012WiFiThe WPS or “Wi-Fi Protected Setup” function allows you to connect wireless devices without entering the password in the device. This is enabled by simultaneously pressing the button on the left-side of the 424RG ONU and the WPS button on the device which it is going to link to for 5 seconds.The 424RG ONU WiFi 802.11b/g /n/ac supports both 2.4 GHz and 5 GHz. When the WPS button on the rear of the 424RG ONU is turned on (pressed in), the wireless network in your home is secure and encryption is activated.USBThere is a USB data connection on the rear of the 424RG ONU that can be used for connection and communications with other computers and electronic devices.INSTALLATIONAfter unpacking the 424RG ONU, inspect it for damage. If damage is noted, file a claim with the carrier and then contact ADTRAN. For more information, refer to the warranty.Installation consists of positioning the 424RG ONU on a desktop and connecting POTS (PHONE), Ethernet, Fiber, and power.Installation GuidelinesThe following are guidelines for this installation.■Read all warnings and cautions before installing or servicing the 424RG ONU.■Do not locate the 424RG ONU in direct sunlight or next to any thermal obstructions.Installation OverviewTo install the 424RG ONU, you will need to complete the following steps:■“Step 1: Install the Base and Connect Fiber”■“Step 2: Connect POTS (PHONE)”■“Step 3: Connect Ethernet”■“Step 4: Connect Power”■“Step 5: Connect USB (optional)”Required toolsStandard technician tools and those listed below are required for installing the 424RG ONU:■Phillips-head screwdriver■Two, RJ-11 connectors■Four, RJ-45 connectors■Wire strippers■RJ-11 and RJ-45 crimpers■PON power meter with wavelength filtering■Fiberscope or videoscopeFor fiber optic connections, the following is required:■ODC Fiber cleaning tool
61287781F2-22A 3Step 2: Connect POTS (PHONE)If POTS cables are not available, use Figure 3 and the following procedure to create the POTS cables:1. Trim the insulation for the subscriber POTS cables.2. Refer to the illustration below and connect the twisted-pair Tip (green) and Ring (Red) to the RJ-11 connector using an RJ-11 crimper.3. Insert the RJ-11 connector in the appropriate PHONE 1 or PHONE 2 jack.Figure 3. POTS (PHONE) ConnectionStep 3: Connect Ethernet The 424RG ONU supports four 1 Gigabit (10/100/1000Base-T) connections (GE 1 to GE 4). If Ethernet cables are not available, use the following procedure and table to create the Ethernet cables:1. Trim the insulation for the subscriber Ethernet cable.2. Connect the wires per the following table using an RJ-45 Crimper.3. Insert the CAT 6 rated cable in the appropriate GE 1 through GE 4 ports on the rear of the 424RG ONU.Step 4: Connect PowerPlug the supplied 12 VDC Power Adapter into the 12V connection on the rear of the chassis. Connect the AC plug to a standard 120 VAC outlet.Step 5: Connect USB (optional)NOTICEDO NOT connect the Power Adapter and an UPS at the same time asthis will cause damage to the 424RG ONU. The ONT can be poweredby either power source, but not both simultaneously.Ethernet RJ-45 Pin-outPin Name Description Color Code1 TRD0+ Transmit/Receive Positive White/Orange2 TRD0- Transmit/Receive Negative Orange3 TRD1+ Transmit/Receive Positive White/Green4 TRD2+ Transmit/Receive Positive Blue5 TRD2- Transmit/Receive Negative White/Blue6 TRD1- Transmit/Receive Negative Green7 TRD3+ Transmit/Receive Positive White/Brown8 TRD3- Transmit/Receive Negative Brown1 2 3 41 = Not Connected2 = Tip3 = Ring4 = Not connectedThe 424RG ONU can typically use an un-interruptible power supply (UPS) if desired. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises. The UPS powers the 424RG ONU and functions as a battery backup unit (BBU) supplying continuous 12 VDC. Refer to the installation material that is provided with the UPS when installing the BBU.UPS ConnectorConnect the UPS to the 8-pin MOLEX connector labeled “UPS” located on the rear of the SFU ONT chassis. Figure 4 illustrates the MOLEX connector on the rear of the ONT.Figure 4. 8-Pin Molex ConnectorThe UPS Power/Alarm Connections Table below defines each pin on the connector. NOTEADTRAN offers a UPS Cable assembly (P/N 1287402G1) for thisconnector.UPS Power/Alarm TableThe following table indicates which pin is associated with each alarm provided through a UPS connection.NOTEIf an UPS is being used and is disconnected, the 424RG ONU is notprotected from power outages, and will send a “Battery Missing”alarm to the OLT.Pin-Out Description Alarm1 Power Input (+12 VDC) -2UPS Status - On Battery 13 UPS Status - Battery Missing 24 Signal Return - 5Power 12 V Return -6 UPS Status - Replace Battery 37 UPS Status - Low Battery 48 No Connection  -
C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGEOR DECREASE IN RELIABILITY.HANDLING PRECAUTIONS REQUIRED.Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online at www.adtran.com/warranty.Trademarks: Brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders.©2016 ADTRAN, Inc. All Rights Reserved.ADTRAN CUSTOMER CARE:From within the U.S.     1.800.726.8663From outside the U.S. +1 256.963.8716PRICING AND AVAILABILITY  1.800.827.0807*61287781F2-22A*LED STATUSThe LEDs are located beneath the plastic housing and are only visible after power has been applied. The following table provides the LED status during normal operations.Label Status IndicationPOWER OffGreenAC or battery offNo FailureFIBER ✷OffGreenGreen Flashing FastNo connection to the OLT, open fiber, failure at the ONT, or power is OffSignal present and is within operating rangeRanging in ProgressINTERNET OffGreenNo IP address configured on WAN Interface, or Power is OffWAN Interface is configured with IP addressGE 1-4 ✷OffGreenGreen Flashing FastLink is down or not equippedLink is upData is being sent or receivedUSB ✷OffGreenGreen Flashing FastPower Off or no device con-nectedDevice connectedData is being sent or received2.4GHZ ✷OffGreenGreen Flashing FastPower is Off, or Wireless 2.4GHz is DisabledWireless 2.4GHz is EnabledData is being sent or received on 2.4GHz5GHZ ✷OffGreenGreen Flashing FastPower is Off, or Wireless 5GHz is DisabledWireless 5GHz is EnabledData is being sent or received on 5GHzPHONE 1-2 ✷OffGreenGreen Flashing SlowUnequipped or on-hook and not ringingLine is off-hookLine in ringing stateWPS ✷OffGreenGreen Flashing FastPower Off or WPS is DisabledWPS is EnabledWPS push button pressed and device is ready to accept con-nectionREGISTRATION IDRegistration ID is performed by Serial Number Activation. This occurs when the 424RG ONU is “Discovered” by the OLT.NOTEIf AOE Auto Upgrade is active, a new 424RG ONU installation will bedetected and a fast blinking FIBER LED will indicate a new softwaredownload has commenced. This may take 5 - 10 minutes to complete.SPECIFICATIONS■Electrical♦Voltage: 12 Volts typical♦Minimum Voltage: 10 Volts♦Maximum Voltage: 13.9 Volts♦Power Consumption: Typical 25.0 watts■Physical♦10.8 inches high (27.4 centimeters)♦7.4 inches deep (18.8 centimeters)♦ 3.2 inches wide (8.1 centimeters)♦Weight: 1 pounds (0.45 kilograms)■Environmental♦Operational Temperature: 32°F to +104°F (0°C to +40°C)♦Storage Temperature: –4°F to 122°F (–20°C to +50°C)♦Relative Humidity: 90%, noncondensing■Optical♦TX min power: +0.5 dBm♦TX max power: +5.0 dBm♦RSSI max sensitivity: –27.0 dBm♦R.0X overload: –8.0 dBm♦TX wavelength: 1310 nm typical♦RX wavelength: 1490 nm typicalMAINTENANCEThe 424RG ONU does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the warranty for further information. Field support for software is provided through upgrade facilities.SAFETY AND REGULATORY COMPLIANCERefer to the Safety and Regulatory Compliance Notice for this product (P/N 61287781F2-17) for detailed safety and regulatory information.Consultez l'avis sur la sécurité et la conformité à la réglementation pour ce produit (61287781F2-17) pour obtenir des renseignements détaillés sur la sécurité et la réglementation.

Navigation menu