Contents
- 1. User Manual
- 2. User Manual Module
- 3. User Manual Regulatory
User Manual
jobAid ADTRAN 424RG CLEI: BVMFG00A_ _ Product P/N: 1287781F2 2 POTS/4GigE with 2.4+5.0 Gig WiFi Optical Network Unit Issue Date: July 2016 Document P/N: 61287781F2-22A The following related online documents and resources provide additional information for this product: Documentation for ADTRAN® Carrier Networks products is available for viewing and download directly from the ADTRAN Support Community website. Go to: https://supportforums.adtran.com/welcome Registration is required. ADTRAN offers training courses on our products, including customized training and courses taught at our facilities or at customer sites. Total Access 5000 GPON OLT User Interface Guide Total Access 5000 Series CLI Dictionary Total Access 5000/5006 Engineering Guide Total Access 5000 Series Fiber to the Premises Deployment Guide ADTRAN 400 Series Residential Gateway ONT Basic Configuration Guide For inquiries, go to: http://adtran.com/training DESCRIPTION The 424RG ONU supports the following features: ■ Two POTS (PHONE) Ports GE 3 ■ Four Ethernet Ports GE 2 ■ 2.4 GHz and 5.0 GHz WiFi GE 1 ■ 12 VDC Power Adapter ■ USB Port 2.4 5.0 ■ Reset Button 12V UPS ■ UPS Connector PHONE 2 PHONE 1 FEATURES GE 4 WPSS RESET USB The ADTRAN 2 POTS/4GigE with 2.4+5.0 Gig WiFi is an Optical Network Unit (424RG ONU) that converts signals being transmitted on optical fiber into electrical signals at a customer location. The illustration at the left displays the front and rear of the 424RG ONU. Resetting the ONT WARNING All settings will return to Factory Defaults; registration provisioning will be lost. Front Rear A reset button is available if the 424RG ONU needs to be rebooted. The Reset button is located just below the USB port on the rear of the 424RG ONU. To reset the 424RG ONU, press the RESET button for 5 seconds or longer. Voice Processing POTS uses in-band signaling tones and currents to determine call status (for example, call request). Because POTS allows for the transfer of audio signals below 3.3 kHz, POTS systems are also used for modems that allow data transmission (referred to as dial up connections). Ethernet Interface The 424RG ONU supports data service through four 10/100/1000Base-T Ethernet interfaces via RJ-45 connectors. Power Power is provided by a 12 VDC Power Adapter that is included with the 424RG ONU. The Power Adapter operates from a main power source input of 100 to 240 VAC, 50/60 Hz, with a nominal output of 12 VDC. The total power consumption with WiFi enabled, 4 Ethernet Ports running and both POTS lines off-hook is approximately 22.0 Watts. A connection for an optional un-interruptible power supply (UPS) is also provided. UPS The 424RG ONU provides an optional connection for an UPS. An UPS is a battery backup system designed to continue providing power when the primary power source is lost. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises and keeps the battery charged. WiFi Installation Steps The WPS or “Wi-Fi Protected Setup” function allows you to connect wireless devices without entering the password in the device. This is enabled by simultaneously pressing the button on the left-side of the 424RG ONU and the WPS button on the device which it is going to link to for 5 seconds. The 424RG ONU must sit upright using the stand provided. DO NOT lay the ONT flat as it may overheat. The 424RG ONU WiFi 802.11b/g /n/ac supports both 2.4 GHz and 5 GHz. When the WPS button on the rear of the 424RG ONU is turned on (pressed in), the wireless network in your home is secure and encryption is activated. USB There is a USB data connection on the rear of the 424RG ONU that can be used for connection and communications with other computers and electronic devices. INSTALLATION After unpacking the 424RG ONU, inspect it for damage. If damage is noted, file a claim with the carrier and then contact ADTRAN. For more information, refer to the warranty. Installation consists of positioning the 424RG ONU on a desktop and connecting POTS (PHONE), Ethernet, Fiber, and power. Installation Guidelines NOTICE To install the 424RG ONU, refer to the figures on the first page and complete the following steps. Step 1: Install the Base and Connect Fiber Ensure the 424RG ONU is not located in direct sunlight and is not located next to any thermal obstructions. To attach the 424RG ONU to the base, refer to Figure 1 and complete the following steps: 1. Remove the two screws from the base of the 424RG ONU. 2. Position the 424RG ONU on the base. 3. Using the two screw provided, secure the base to the 424RG ONU. 4. Thread the fiber cable through the opening in the base. If there is excess fiber, carefully wrap it around the Fiber Tray. 5. Remove the plug from the SC/APC Connector and insert the fiber cable. Retain this plug and insert it in the fiber connection when the fiber cable is not connected. This will protect the optical portion of the connection. Figure 2 illustrates the 424RG ONU after the base has been attached. The following are guidelines for this installation. ■ Read all warnings and cautions before installing or servicing the 424RG ONU. ■ Do not locate the 424RG ONU in direct sunlight or next to any thermal obstructions. Screw Screw Fiber Tray SC/APC Connector Installation Overview Fiber Opening To install the 424RG ONU, you will need to complete the following steps: ■ “Step 1: Install the Base and Connect Fiber” ■ “Step 2: Connect POTS (PHONE)” ■ “Step 3: Connect Ethernet” ■ “Step 4: Connect Power” Figure 1. Attach 424RG ONU to Base and Connect Fiber ■ “Step 5: Connect USB (optional)” Required tools Standard technician tools and those listed below are required for installing the 424RG ONU: ■ Phillips-head screwdriver ■ Two, RJ-11 connectors ■ Four, RJ-45 connectors ■ Wire strippers ■ RJ-11 and RJ-45 crimpers ■ PON power meter with wavelength filtering 2.4 5.0 ■ Fiberscope or videoscope For fiber optic connections, the following is required: ■ ODC Fiber cleaning tool Figure 2. 424RG ONU with Base Attached 61287781F2-22A Step 2: Connect POTS (PHONE) If POTS cables are not available, use Figure 3 and the following procedure to create the POTS cables: 1. Trim the insulation for the subscriber POTS cables. 2. Refer to the illustration below and connect the twisted-pair Tip (green) and Ring (Red) to the RJ-11 connector using an RJ-11 crimper. 3. Insert the RJ-11 connector in the appropriate PHONE 1 or PHONE 2 jack. 1234 The 424RG ONU can typically use an un-interruptible power supply (UPS) if desired. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises. The UPS powers the 424RG ONU and functions as a battery backup unit (BBU) supplying continuous 12 VDC. Refer to the installation material that is provided with the UPS when installing the BBU. UPS Connector Connect the UPS to the 8-pin MOLEX connector labeled “UPS” located on the rear of the SFU ONT chassis. Figure 4 illustrates the MOLEX connector on the rear of the ONT. 1 = Not Connected 2 = Tip 3 = Ring 4 = Not connected Figure 3. POTS (PHONE) Connection Figure 4. 8-Pin Molex Connector Step 3: Connect Ethernet The 424RG ONU supports four 1 Gigabit (10/100/1000Base-T) connections (GE 1 to GE 4). If Ethernet cables are not available, use the following procedure and table to create the Ethernet cables: The UPS Power/Alarm Connections Table below defines each pin on the connector. NOTE ADTRAN offers a UPS Cable assembly (P/N 1287402G1) for this connector. 1. Trim the insulation for the subscriber Ethernet cable. 2. Connect the wires per the following table using an RJ-45 Crimper. Ethernet RJ-45 Pin-out Pin Name Description Color Code TRD0+ Transmit/Receive Positive White/ Orange TRD0- Transmit/Receive Negative UPS Power/Alarm Table The following table indicates which pin is associated with each alarm provided through a UPS connection. Pin-Out Description Alarm Power Input (+12 VDC) Orange UPS Status - On Battery UPS Status - Battery Missing TRD1+ Transmit/Receive Positive White/Green TRD2+ Transmit/Receive Positive Blue Signal Return Power 12 V Return TRD2- Transmit/Receive Negative White/Blue TRD1- Transmit/Receive Negative Green UPS Status - Replace Battery UPS Status - Low Battery No Connection TRD3+ Transmit/Receive Positive White/Brown TRD3- Transmit/Receive Negative Brown 3. Insert the CAT 6 rated cable in the appropriate GE 1 through GE 4 ports on the rear of the 424RG ONU. Step 4: Connect Power NOTE If an UPS is being used and is disconnected, the 424RG ONU is not protected from power outages, and will send a “Battery Missing” alarm to the OLT. Plug the supplied 12 VDC Power Adapter into the 12V connection on the rear of the chassis. Connect the AC plug to a standard 120 VAC outlet. Step 5: Connect USB (optional) NOTICE DO NOT connect the Power Adapter and an UPS at the same time as this will cause damage to the 424RG ONU. The ONT can be powered by either power source, but not both simultaneously. 61287781F2-22A LED STATUS REGISTRATION ID The LEDs are located beneath the plastic housing and are only visible after power has been applied. The following table provides the LED status during normal operations. Registration ID is performed by Serial Number Activation. This occurs when the 424RG ONU is “Discovered” by the OLT. Label If AOE Auto Upgrade is active, a new 424RG ONU installation will be detected and a fast blinking FIBER LED will indicate a new software download has commenced. This may take 5 - 10 minutes to complete. POWER FIBER INTERNET GE 1-4 USB 2.4GHZ 5GHZ PHONE 1-2 WPS Status Indication Off AC or battery off Green No Failure Off No connection to the OLT, open fiber, failure at the ONT, or power is Off Green Signal present and is within operating range ✷ Green Flashing Fast Ranging in Progress Off No IP address configured on WAN Interface, or Power is Off NOTE SPECIFICATIONS ■ Electrical ♦ Voltage: 12 Volts typical ♦ Minimum Voltage: 10 Volts ♦ Maximum Voltage: 13.9 Volts ♦ Power Consumption: Typical 25.0 watts ■ Physical ♦ 10.8 inches high (27.4 centimeters) ♦ 7.4 inches deep (18.8 centimeters) Green WAN Interface is configured with IP address Off Link is down or not equipped Green Link is up ✷ Green Flashing Fast Data is being sent or received Off Power Off or no device connected Green Device connected ♦ TX min power: +0.5 dBm ✷ Green Flashing Fast Data is being sent or received ♦ TX max power: +5.0 dBm Off Power is Off, or Wireless 2.4GHz is Disabled Green Wireless 2.4GHz is Enabled ✷ Green Flashing Fast Data is being sent or received on 2.4GHz Off Power is Off, or Wireless 5GHz is Disabled Green Wireless 5GHz is Enabled ✷ Green Flashing Fast Data is being sent or received on 5GHz Off Unequipped or on-hook and not ringing Green Line is off-hook ✷ Green Flashing Slow Line in ringing state SAFETY AND REGULATORY COMPLIANCE Off Power Off or WPS is Disabled Green WPS is Enabled Refer to the Safety and Regulatory Compliance Notice for this product (P/N 61287781F2-17) for detailed safety and regulatory information. ✷ Green Flashing Fast WPS push button pressed and device is ready to accept connection Consultez l'avis sur la sécurité et la conformité à la réglementation pour ce produit (61287781F2-17) pour obtenir des renseignements détaillés sur la sécurité et la réglementation. ♦ 3.2 inches wide (8.1 centimeters) ♦ Weight: 1 pounds (0.45 kilograms) ■ Environmental ♦ Operational Temperature: 32°F to +104°F (0°C to +40°C) ♦ Storage Temperature: –4°F to 122°F (–20°C to +50°C) ♦ Relative Humidity: 90%, noncondensing ■ Optical ♦ RSSI max sensitivity: –27.0 dBm ♦ R.0X overload: –8.0 dBm ♦ TX wavelength: 1310 nm typical ♦ RX wavelength: 1490 nm typical MAINTENANCE The 424RG ONU does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the warranty for further information. Field support for software is provided through upgrade facilities. Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online at www.adtran.com/warranty. Trademarks: Brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. ©2016 ADTRAN, Inc. All Rights Reserved. ADTRAN CUSTOMER CARE: From within the U.S. 1.800.726.8663 From outside the U.S. +1 256.963.8716 C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. PRICING AND AVAILABILITY 1.800.827.0807 *61287781F2-22A*
Source Exif Data:
EXIF Metadata provided by EXIF.tools