JOBAID

BR1/10 2X MINI ISDN CHANNEL BANK

BR1/10 2X
CLEI: D4MEXZB02_ _

COMMONS /OPTIONS

BCU MANUAL TESTING DIP SWITCHES

BR1/10 Common Unit required for each side of the 2X chassis
H-LIU – Combination PAU/LIU P/N 1150179L1
CLEI: D4IMEG02AA
This unit replaces the individual PAU and LIU cards (shown).

LB ON/OFF
REMOTE/LOC

PAU – Power/Alarm Unit
P/N 1150078L2
CLEI: D4CIJ8Y2AA
This common unit has no options switches to set, verify the 1 AMP fuse is properly seated..
LIU - Line Interface Unit
P/N 1150079L2
CLEI: D4CIPT02AA
The LIU has no option switches to set. The DB9 connector and rotary switches are used for
testing only.

DS0/DS1

BCU- Bank Controller Unit
P/N 1150080L1
CLEI: D4CIS7Z2AA
The BCU is the only common unit with option settings on the printed circuit board.
BCU Option Settings:
S1-1 through S1-3 DSX-1 Line Build Out: 0-133ft/133-266/266-399/399-533/533-655
S2-1 Line Code Format: B8ZS/AMI
S2-2 Framing Format: ESF/SF
S2-3 Remote Loopback Selection: PAYLOAD/LINE
S2-4 and S2-5 Timing Mode:EXTERNAL/LOCAL/LOOP/CAU
S2-6 Bank Mode: 8DSL/10DSL
S2-7 through S2-9 Terminal Mode: D4/ D1D/SLC Mode 1D1D/SLC Mode 3 D4/ D1D
Mini U-BR1TE Switch Options
SW1
SW2
SW3
SW4
SW5
SW6
SW7

ON
B1 SER. ON
B2 SER. ON
D SER. ON
SC ON
LULT
LULT
ZBS ON

61150081L2-22A
0201

OFF
B1 SER. OFF
B2 SER. OFF
D SER. OFF
S.C. OFF
LUNT
LUNT
ZBS OFF

Faceplate LED on mini U-BR1TE
Red- Indicates no sync to ISDN Switch/NT1
Green- Indicates sync to ISDN Switch/NT1

Mini U-BR1TE Compatible Access Cards
Mini BR1/10 ISDN U-BR1TE
CLEI: D4C1A2T2AA (Shown)
Mini BR1/10 TR ISDN UBR1TE
CLEI: D4CIA9T2AA
Mini BR1/10 TR DDS DP
CLEI: D4D3M14DAA
Mini BR1/10 DSO DP
CLEI: D4D3D3HDAA

1150077LX
1152182LX
1151061LX

B1/B2

Enables and disables DS1 loopbacks for REMOTE/LOC
direction depending on switch setting below
REMOTE in ESF will initiate a loopback to the far-end BR1/10
side when LB is switched to ON
REMOTE in SF will initiate a loopback at the local BR1/10 side
when LB is switched to ON
LOC provides internal loopback at the T1 data stream at the
local BR1/10 side when LB is switched to ON
When set towards DS1 controls the REMOTE/LOC loopback
directions and initiates loopback with LB ON/OFF switch
When set towards DS0 controls the B1/B2 channel selection.
The TEST recessed button initiates test selected on LIU rotary
switches. This option is normally in the DS0 position once the
BR1/10 side is in service
When the switch above is in the DS0 position, B1 and B2
selects the appropriate B-Channel to be tested

BR1/10 Slot to Channel Bank Slot Cross-Reference Compatibility
BR1/10

1

2

3

4

5

6

7

8

9

10

D4/DID, SLC Mode 3

1

4

7

10

13

16

19

22

N/A

N/A

SLC Mode 1 (Physical Slots)

1

2

4

5

7

8

10

11

N/A

N/A

Digroup-A

1/2

3/4

7/8

9/10

13/14

15/16

19/20

21/22

N/A

N/A

Digroup-B

25/26

27/28

31/32

33/34

37/38

39/40

43/44

45/46

N/A

N/A

Digroup-C

49/50

51/52

55/56

57/58

61/62

63/64

67/68

69/70

N/A

N/A

Digroup-D

73/74

75/76

79/80

81/82

85/86

87/88

91/92

93/94

N/A

N/A

1

4

7

10

13

16

19

22

N/A

N/A

Digroup A/B

25/26

31/32

37/38

43/44

1/2

7/8

13/14

19/20

N/A

N/A

Digroup C/D

73/74

79/80

85/86

91/92

49/50

55/56

61/62

67/68

N/A

N/A

SLC Mode 3 (Physical Slots)

1150103L1

C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

■ For a complete Installation and Maintenance Practice faxback: (877) 457-5007, Document # 662. Please have your fax number available. ■

BR1/10 2X MINI ISDN CHANNEL BANK
BCU LEDs

BCU DIP Test Switch

Channel Selection

LIU

1150079L2
10

1

2

9

3
4

8
7

LPTX
NT1

ADR3

AD
R1
ADR2

IN

DS0
B2

OFF AY
LOC
DS1

4

LB ON
REMOTE

3

AD
R6
AD
R5
ADR4

CRTX

5

2

LPBX

6

1

T
E
S
T

B1

TEST

TP
ESF
B8ZS

10DSL
EXT
LOOP

M
O
N

DS1-LOC

OUT

LP-SYNC
CR-SYNC
DSO-LB

DB-9 Connector
Bantam Jacks

PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61150081L2-22A

BCU 1150080L1

AR
RCV
SF
ON

AMI
BDSL

1

2

3

4

5

6

7

8

9

10

LOC
CAU
RMT
CRC
CRC

Recessed Test Push Button

ACT

Loopback Address

LOOPBACK TEST (ADR6, NT1)
Loopbacks in the network to customer direction can be initiated from either the ISDN switch (eoc) or
the BR1/10 LIU and BCU. The down-stream direction is automatically selected based on the channel
unit position in the circuit. To initiate a loopback, perform the following steps:
1. Insert TX and RX bantam plugs of the DS0 digital test set (i.e. TPI 108/109) to the TEST jacks of the
LIU
2. Connect test set clock interface to DB9 connector of the LIU and configure the test set for Near
Logic and 64kb/s
3. Select the desired U-BRITE using the DSL rotary switch on the LIU( the selected U-BRITE LED
flashes red and green for 3 seconds
4. Select the desired loopback address using the address rotary switch on the LIU (note: ADR1 is
always the U-BRITE your test set is connected to
5. Select DS0 option and select the desired Bearer channel B1/B2 dip switches on the BCU
6. Press the recessed TEST push-button on the BCU to initiate the loopback test
7. The DS0 LB status LED on the BCU will illuminate if the loopback is successful and will not
illuminate if the loopback failed
8. Send and Receive 2047 to the established loopback and observe the DS0 digital test set for bit
errors
9. It is not necessary to exit the test mode to select additional addresses (ADR2, NT1) or to change to
B1/B2 channels
10. To terminate the loopback, press the TEST push-button and the amber DS0-LB LED will go out

Indicator
AY
AR
TP
RCV
ESF
SF
B8ZS
AMI
10DSL
8DSL
EXT
LOC

Color
Amber
Red
Amber
Red
Green
Green
Green
Green
Green
Green
Green
Green

Description
ON indicates a Yellow Alarm is being received from the T1 carrier facility
ON indicates the BR1/10 side is in a Red Alarm condition
ON indicates Trunk Processing is active on all U-BRITEs (10)
ON indicates a loss of framing of T1 signal from the T1 carrier facility
ON indicates the T1 Extended SuperFrame format is selected
ON indicates the T1 SuperFrame format is selected
ON indicates T1 B8ZS line coding is selected
ON indicates T1 AMI line coding is selected
ON indicates D Channel 4:1 TDM mode is selected to transport 10 BRIs
ON indicates TR-397 3-DS0 framing across the T1 facility to transport 8 BRIs
ON indicates External timing input is selected (BITS)
ON indicates BR1/10 side is using a locally generated clock source to time the
T1 network
LOOP
Green
ON indicates BR1/10 clock is recovered clock from the T1 network
CAU
Green
ON indicates clock is recovered from the DSL position #1 to time the T1 network
DS1-LOC Green
ON indicates the BR1/10 side is in a Local DS1 Loopback
RMT
Green
ON indicates the unit has initiated remote DS1 loopback when set in ESF mode
FLASHING indicates it responded to remotely commanded loopback, or has
provided a loopback path for the T1 data-stream in SF mode
LP-SYNC* Red
ON indicates the U-interface is out of sync for the selected channel unit
LP-CRC*
Red
In normal operation flashes upon receiving NEBEs from the loop. In Local PM
mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected from the
loop
CR-SYNC* Red
ON indicates no TR-397 framing across the T1 carrier for the selected channel
CR-CRC* Red
In normal operation flashes upon receiving NEBEs from the T1 carrier. In Local
PM mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected
from the T1
DS0-LB*
Amber
ON indicates the selected U-BRITE is in a 2B+D commanded eoc loopback.
Flashing once per second=B1 is looped, flashing twice per second=B2 is looped
ACT*
Green
ON indicates the customer’s NT1 has successfully exchanged ACT bits with the
network for the selected channel
* Status is for the channel unit selected on the DSL 10-position rotary switch on the LIU of the the
BR1/10 side

WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s
order for use in the U.S. is ten (10) years. For a complete faxback copy of ADTRAN’s U.S. and
Canada Carrier Networks Equipment Warranty, call (877) 457-5007, Document #414.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2002:01:09 17:58:23
Producer                        : Acrobat Distiller 4.0 for Macintosh
Author                          : Scott Alford
Title                           : 61150081L2-22A
Creator                         : QuarkXPress(tm) 4.1
Modify Date                     : 2002:01:09 17:58:41-06:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu