ADTRAN TRC6420 Tracer 6420 User Manual 612806420L1 1A

Adtran Tracer 6420 612806420L1 1A

Users Manual Revised

612806420L1-1AJanuary 2005TRACER 6420System Manual12806420L1A TRACER 6420 5.8 GHz System (Plan A)12806420L1B TRACER 6420 5.8 GHz System (Plan B)
 Trademarks TRACER 6420 System Manual 2 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ATrademarksAny brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders.To the Holder of the ManualThe contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.About this ManualThis manual provides a complete description of the TRACER 6420 system and system software. The purpose of this manual is to provide the technician, system administrator, and manager with general and specific information related to the planning, installation, operation, and maintenance of the TRACER 6420. This manual is arranged so that needed information can be quickly and easily found. 901 Explorer BoulevardP.O. Box 140000Huntsville, AL 35814-4000Phone: (256) 963-8000Copyright © 2005 ADTRAN, Inc.All Rights Reserved.Printed in U.S.A.
TRACER 6420 System Manual  Revision History612806420L1-1A Copyright © 2005 ADTRAN, Inc. 3Revision HistoryDocument RevisionDate Description of ChangesADecember 2004 Initial release of manual to include the TRACER 6420 (5.8 GHz integrated system) and the Quad T1 and Ethernet Switch modules.Notes provide additional useful information.Cautions signify information that could prevent service interruption.Warnings provide information that could prevent damage to the equipment or endangerment to human life.
 Safety Instructions TRACER 6420 System Manual 4 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ASafety InstructionsWhen using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury:1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning.3. Do not use the telephone to report a gas leak in the vicinity of the leak.4. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for special disposal instructions.Save These Important Safety Instructions
TRACER 6420 System Manual  FCC-Required Information612806420L1-1A Copyright © 2005 ADTRAN, Inc. 5FCC-Required InformationFederal Communications Commission Radio Frequency Interference StatementThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.Radio Frequency Interface StatementThis equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, Subpart C of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause interference to radio communications.The limits are designed to provide reasonable protection against such interference in a residential situation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna of the affected radio or television.• Increase the separation between the equipment and the affected receiver.• Connect the equipment and the affected receiver to power outlets on separate circuits.• Consult the dealer or an experienced radio/TV technician for help.Shielded cables must be used with this unit to ensure compliance with Class A FCC limits.Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate the equipment.
 FCC-Required Information TRACER 6420 System Manual 6 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AFCC Output Power RestrictionsThe FCC does not require licensing to implement this device. License-free operation in the industrial, scientific, and medical band is documented in FCC Rules Part 15.247. It is the responsibility of the individuals designing and implementing the radio system to ensure compliance with any pertinent FCC Rules and Regulations. This device must be professionally installed.Exposure to Radio Frequency FieldsThe TRACER 6420 is designed to operate at 5.8 GHz with 100 mW maximum transmit power.This level of RF energy is below the Maximum Permissible Exposure (MPE) levels specified in FCC OET 65:97-01. The installation of high gain antenna equipment in the system configuration may create the opportunity for exposure to levels higher than recommended for the general population at a distance less than 15 feet (4.6 meters) from the center of the antenna. The following precautions must be taken during installation of this equipment:• The installed antenna must not be located in a manner that allows exposure of the general population to the direct beam path of the antenna at a distance less than 15 feet (4.6 meters). Installation on towers, masts, or rooftops not accessible to the general population is recommended; or• Mount the antenna in a manner that prevents any personnel from entering the area within 15 feet (4.6 meters) from the front of the antenna.• It is recommended that the installer place radio frequency hazard warnings signs on the barrier that prevents access to the antenna.• Prior to installing the antenna to the TRACER output, make sure the power is adjusted to the settings specified in section 2 of this manual.• During antenna installation, be sure that power to the TRACER equipment is turned off in order to prevent any energy presence on the coaxial connector.• During installation and alignment of the antenna, do not stand in front of the antenna assembly.• During installation and alignment of the antenna, do not handle or touch the front of the antenna.These simple precautions must be taken to prevent general population and installation personnel from exposure to RF energy in excess of specified MPE levels.Verify the antenna installation meets all regulations specified in the National Electric Code (NEC) Article 810.
TRACER 6420 System Manual  Warranty and Customer Service612806420L1-1A Copyright © 2005 ADTRAN, Inc. 7Warranty and Customer ServiceADTRAN will repair and return this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty.Customer Service, Product Support Information, and TrainingADTRAN will repair and return this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. A return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, training, or more information, use the contact information given below.Repair and ReturnIf you determine that a repair is needed, please contact our Customer and Product Service (CaPS) department to have an RMA number issued. CaPS should also be contacted to obtain information regarding equipment currently in house or possible fees associated with repair.Identify the RMA number clearly on the package (below address), and return to the following address:Pre-Sales Inquiries and Applications SupportYour reseller should serve as the first point of contact for support. If additional pre-sales support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, latest product documentation, application briefs, case studies, and a link to submit a question to an Applications Engineer. All of this, and more, is available at:When needed, further pre-sales assistance is available by calling our Applications Engineering Department.CaPS Department (256) 963-8722 ADTRAN Customer and Product Service901 Explorer Blvd. (East Tower)Huntsville, Alabama 35806RMA # _____________http://support.adtran.comApplications Engineering (800) 615-1176
 Customer Service, Product Support Information, and Training TRACER 6420 System Manual 8 Copyright © 2005 ADTRAN, Inc. 612806420L1-1APost-Sale SupportYour reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble-shooting tools. All of this, and more, is available at:When needed, further post-sales assistance is available by calling our Technical Support Center. Please have your unit serial number available when you call.Maintenance SupportThe ADTRAN Custom Extended Services (ACES) program offers multiple types and levels of maintenance services which allow you to choose the kind of assistance you need. This support is available at:For questions, call the ACES Help Desk. TrainingThe Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and functions while covering applications of ADTRAN's product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at your site. For more information about training, please contact your Territory Manager or the Enterprise Training Coordinator.http://support.adtran.comTechnical Support (888) 4ADTRANhttp://www.adtran.com/acesACES Help Desk (888) 874-ACES (2237) Training Phone (800) 615-1176, ext. 7500 Training Fax (256) 963-6700Training Email training@adtran.com
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  9Table of ContentsSection 1 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11This section of ADTRAN’s TRACER 6420 System Manual is designed for use by network engineers, planners, and designers for overview information about the TRACER 6420 systems.Section 2 Microwave Path Engineering Basics . . . . . . . . . . . . . . . . . . . . . . . . . . 13Explains the basics of analyzing a wireless microwave link or path. Defines significant param-eters and makes several installation recommendations.Section 3 Engineering Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Provides information to assist network designers with incorporating the TRACER 6420 system into their networks.Section 4 Network Turnup Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Provides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit.Section 5 User Interface Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Provides detailed descriptions of all menu options and configuration parameters available for the TRACER 6420.Section 6 Detail Level Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port . . . . . . . . . . . . . . . . . . . . . . 73DLP-2 Logging in to the TRACER 6420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75DLP-3 Setting IP Parameters for the TRACER 6420. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77DLP-4 Verifying Communications Over an IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81DLP-5 Updating the Firmware Using TFTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85DLP-6 Updating the Firmware Using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Section 7 MIBs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Provides a listing of SNMP Management Information Bases (MIBs) supported by the| TRACER 6420. Traps supported for each MIB are also listed.Section 8 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103Provides helpful information for troubleshooting common configuration problems for the TRACER 6420.
 Table of Contents TRACER 6420 System Manual 10 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  11SYSTEM DESCRIPTIONThis section of ADTRAN’s TRACER 6420 System Manual is designed for use by network engineers, planners, and designers for overview information about the TRACER 6420 systems.It contains general information and describes physical and operational concepts, network relationships, provisioning, testing, alarm status, and system monitoring. This section should be used in conjunction with Section 3, Engineering Guidelines, of this manual.CONTENTSSystem Overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Features and Benefits   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Configuration and Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   12Operational . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   12Available Interface Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   12
Section 1  System Description TRACER 6420 System Manual 12 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. SYSTEM OVERVIEWThe TRACER 6420 provides license-free scalable connectivity for service providers and corporate networks. These radios feature two modular network interface ports that can accommodate various combinations of T1 and Ethernet option cards up to 8xT1 (16.384 Mbps). This flexibility provides customized TDM and packet solutions for voice and data applications in a single platform. The TRACER 6420 radios provide carrier class point-to-point connectivity up to thirty miles in the 5.8 GHz license-free Industrial, Science, and Medical (ISM) band. Complete network management is supported via SNMP, Telnet access, and a VT100 craft port. SNMP traps are implemented for all RF link and T1/Ethernet alarm conditions, enabling remote installations to report outages without requiring a truck roll to diagnose problems. Version 2 standard MIBs are supported for all interface cards, while an enterprise-specific MIB is provided for radio functionality. Triple-DES security provides additional protection from unauthorized access without requiring any additional external security appliances. Encryption can also be disabled altogether. Future upgrades and enhancements can be added through FLASH firmware downloads via TFTP (on the Ethernet interface) or XMODEM on the craft port.Receive sensitivity is optimized through the use of extensive forward error correction and high-performance receiver design techniques. Dynamic receive sensitivity allows the user to increase receiver performance by decreasing the delivered bandwidth. This feature maximizes link performance by customizing the delivered bandwidth to the specific needs of the installation. Three software selectable channel plans are supported to simplify frequency coordination at co-located sites. Channel plans are easily changed via any of the software management interfaces without the added expense of hardware upgrades or spare filter assemblies.TRACER wireless solutions maximize equipment density through the combination of compact size (only 1U rack space required), low power consumption, and high thermal transfer. TRACER systems can be deployed at twice the density of other available wireless products.2. FEATURES AND BENEFITSThe following is a brief list of the TRACER 6420 features and benefits:Configuration and Management• Easy to use VT100 control port (RS-232 interface) for configuration and monitoring• Remote configuration of both ends of the wireless link, from each end of the linkOperational• No license required per FCC Rules Part 15.247• Frequency: 5.725 to 5.850 GHz• Point-to-point, up to 30 miles• 1-U high unit for easy rack-mountingAvailable Interface Modules• Quad T1 Module (P/N 1280040L1)• Quad Ethernet Switch Module (P/N 1280050L1)
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  13 MICROWAVE PATH ENGINEERING BASICSExplains the basics of analyzing a wireless microwave link or path. Defines significant parameters and makes several installation recommendations.CONTENTSLine-of-Sight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Terminology  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   14Decibels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Calculating the Fade Margin  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Receiver Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Antenna Gain  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   16Transmitted Power (PT)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   16Carrier Wavelength (l) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17Path Distance (d)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17System Losses (L)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17Path Loss (LP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   18Receiver Sensitivity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Antenna Information   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Antenna Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   20TRACER RSSI Test Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20Antenna Beam Patterns  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   20Fresnel Zones, Earth Curvature, and Antenna Heights  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   21Other Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Path Availability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   23FIGURESFigure 1. Example Microwave Path with Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   16Figure 2. Typical Antenna Beam Pattern  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   21TABLESTable 1. Antenna Gain for Given Dish Diameters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Table 2. Typical Coaxial Loss for Common Cable Types  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 3. Path Loss for Given Path Lengths   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 4. Receiver Sensitivity for the TRACER 6420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 5. Minimum Antenna Height for Given Path Lengths   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 14 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. LINE-OF-SIGHTThe TRACER 6420 system is designed for operation in the license-free 5.725 GHz to 5.850 GHz industrial, scientific, and medical (ISM) band. Radio wave propagation in this band exhibits microwave characteristics which are ideally suited for point-to-point, line-of-sight communications. Line-of-sight requires that the transmitting antenna and receiving antenna are able to “see” each other, and that the straight-line path between the two antennas is free of obstructions such as buildings, trees, mountains, and in longer paths, even the curvature of the earth. For maximum signal strength, the area around the visual line-of-sight where microwave signals reflect (Fresnel zone) must also be free of obstructions. Fresnel zones are discussed in more detail on page 21.Terminology2. DECIBELSUnderstanding the decibel (dB) format is key when discussing microwave path engineering because the received signal power is often expressed in decibel format. In general, any quantity can be expressed in decibels. If the quantity x is a power level (in Watts), the decibel equivalent is defined asIf the quantity x is referenced to a milliwatt (mW), then the decibel-milliwatt (dBm) is used instead of a generic decibel.Using the decibel format simplifies power calculations by reducing multiplication and division operations into addition and subtraction operations.3. CALCULATING THE FADE MARGINThe fade margin (F ) is a value in decibels (dB) that represents the amount of signal reduction that can be tolerated before the link exceeds the specified bit error rate (BER). Fade margin is simply the difference between the available signal power at the receiver (PR ) and the receiver sensitivity (Psens ). Point-to-Point Wireless communication from a single site to another individual site. Contrast with point-to-multipoint.Line-of-Sight An unobstructed, direct path exists between the transmitting and the receiving antennas.It is imperative to determine whether the proposed microwave path is suitable (at a minimum) for ideal, nondistorted signals before attempting installation.xdB 10 log10 x()⋅=(dB)xdBm 10 log10x1mW-------------⎝⎠⎛⎞⋅=(dBm)FPRPsens–=(dB)= PT + GT + GR - L - LP - Psens
TRACER 6420 System Manual Section 2  Microwave Path Engineering Basics612806420L1-1A Copyright © 2005 ADTRAN, Inc. 15where the variables in the equations are defined asPRreceived power (dBm) PTtransmitted power (adjustable up to 20 dBm maximum) GTtransmit antenna gain (decibels referenced to an isotropic source – dBi) GRreceive antenna gain (dBi) Lother losses (RF coaxial cable, etc. – dB) LPpath loss (dB)Higher levels of fade margin indicate stronger protection against signal fading and a more reliable link. For most applications, 20 to 30 dB of fade margin should ensure a reliable link. The following sections further discuss the necessary power calculations and their components.4. RECEIVER POWERThe viability of a particular microwave path is determined by the power of the transmitted microwave signal, the transmit and receive antenna gain, distance, and accumulated system losses (such as RF coaxial cable losses and path loss).The equation relating received signal power to the other microwave parameters isor (in decibel notation)where the variables in the equations are defined asPRreceived power (dBm) PTtransmitted power (adjustable up to 20 dBm maximum) GTtransmit antenna gain (decibels referenced to an isotropic source – dBi) GRreceive antenna gain (dBi) λcarrier wavelength (meters) dpath distance (meters) Lother losses (RF coaxial cable, etc. – dB) LPpath loss (dB)When using decibel notation, all quantities must be individually converted to decibels prior to performing addition and subtraction.PRPTGTGRλ24π()2d2L------------------------------=(Watts, W)(decibels referenced to a milliwatt, dBm)PR = PT + GT + GR - L - LP
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 16 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AFigure 1 illustrates a wireless link configuration containing all the parameters necessary for the power budget analysis.Figure 1.  Example Microwave Path with ParametersThe following sections further discuss the power budget analysis and its components.Antenna GainActual transmit and receive antenna gain values depend strictly upon the physical characteristics of the antennas installed for each link. In other words, the size of the dish determines the antenna gain. Using a parabolic dish antenna results in the best performance. Antenna gains are specified in terms of decibels of gain referenced to an isotropic source (dBi). An isotropic source is a hypothetical antenna having equal radiation in all directions. Typical antenna gains are listed in Table 1; however, dish manufacturers can provide gains for specific types of antennas.Transmitted Power (PT)The FCC specifies the maximum transmitter power used for antennae of a given gain. FCC Rules (Part 15, Subpart 247) allow for a maximum transmit power of 1 Watt (30 dBm). Since the TRACER 6420 maximum transmit power is 100 milliwatts, there is no reduction in transmitter output power required.Table 1.   Antenna Gain for Given Dish DiametersDish Diameter(in feet)Gain at 5.8 GHz(in dBi)228.5434.2637.5840.710 42.512 44.2 GTGRd, LPPTPRλLL
TRACER 6420 System Manual Section 2  Microwave Path Engineering Basics612806420L1-1A Copyright © 2005 ADTRAN, Inc. 17Carrier Wavelength (λ)The carrier wavelength is the physical wavelength of the main RF carrier being used for communication, and is usually approximated at the center frequency of the band (which is 5787.5 MHz for the  TRACER 6420). The carrier wavelength calculations follow:λ = c / f (meters)where c = speed of light (in meters) f = frequency (in Hz)resulting in the following carrier wavelength:λ = 3.00 x 108 / 5787.5 x 10 5  = 0.0518 m or 5.18 cmPath Distance (d)The path distance is simply the physical distance between the transmit and receive antennas. For the TRACER 6420, these distances can range up to 30 miles. System Losses (L)System losses are defined by RF coaxial cable loss, connector losses, and losses added from any additional lightning protection devices for the power budget analysis. Coaxial cable is required to attach the TRACER 6420 to the antenna. The length of the cable varies from a few feet to hundreds of feet, depending upon your application and the proximity of the TRACER 6420 to the antenna. Various grades of coaxial cable will work sufficiently well for connecting the TRACER 6420 unit to the antenna. A low-loss coaxial cable will minimize cable losses.One end of the coaxial cable requires an N-type male connector (plug) to mate with the TRACER 6420 unit. The other end of the coaxial cable requires a connector compatible with the antenna chosen for the installation (usually an N-type male connector). Additionally, ADTRAN recommends that the outdoor connector on the coaxial cable be weatherproofed to prevent corrosion and electrical shorting.In areas where lightning strikes are frequent, a lightning arrestor should be installed directly on the antenna coaxial cable. Installing lightning arrestors helps protect the RF electronics (including the TRACER 6420 unit) in the downstream path from damaging voltages and currents.
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 18 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ATable 2 gives typical loss figures for some of the more common coaxial cable types (per 100 feet).Path Loss (LP)Path loss is the estimated attenuation between the transmit and receive antennas caused by signal separation and scattering. The path loss is considered basic transmission loss over the microwave link. The following expression calculates path loss:where fcarrier frequency (Hz) λcarrier wavelength (c / f) (meters) dpath distance (meters) cspeed of light, free-space (meters)orwhere d is expressed in miles and f in GHzPath loss, as shown here, increases rapidly as either the path length increases or the carrier wavelength decreases (which happens as the carrier frequency increases). Therefore, longer microwave paths naturally experience more path loss than shorter paths. Likewise, higher frequency microwave communication experiences more path loss than lower frequency microwave communication.Table 2.   Typical Coaxial Loss for Common Cable TypesCable Type 5.8 GHz Loss/100 ft (in dB)RG58 N/ARG8 (air) N/ARG8 (foam) N/A1/4” Coax 11.363/8” Coax 9.651/2” Coax 6.495/8” Coax 4.907/8” Coax N/A1 1/4” Coax N/A1 5/8” Coax N/A5.8 GHz Elliptical Waveguide 1.23LP4πdλ----------⎝⎠⎛⎞24πdfc------------⎝⎠⎛⎞2== (dB)LP96.6 20 log10 d() 20·log+10 f()⋅+= (dB)
TRACER 6420 System Manual Section 2  Microwave Path Engineering Basics612806420L1-1A Copyright © 2005 ADTRAN, Inc. 19Table 3 lists path loss values for various path lengths for the TRACER 6420 5.8 GHz system. Values not listed in the table can be interpolated from those listed.5. RECEIVER SENSITIVITYReceiver sensitivity is a value expressed in decibels referenced to one milliwatt (dBm) that corresponds to the minimum amount of signal power needed at the receiver to achieve a given bit error rate (BER). Receiver sensitivity is usually a negative number of decibels, and smaller receiver sensitivity (higher quantity negative number) is better for a given BER. Several factors affect receiver sensitivity, including the data bandwidth of the wireless link and the amount of additional signal degradation introduced in the receiver electronics.Receiver sensitivity of the TRACER 6420 is dynamic as a function of the desired bandwidth; receiver sensitivity improves as delivered bandwidth decreases. TRACER bandwidth is provided in the form of 8 channels available for mapping to the support modules. For T1 Modules, each channel mapped represents a single T1 interface. For Quad Ethernet Switch Modules, each channel mapped represents 2 Mb of switch data delivered to the module. In situations where 8-channel connectivity is not required, the delivered bandwidth can be decreased to 4 or 2 channels, and the receiver sensitivity will be improved as follows:Table 3.   Path Loss for Given Path LengthsPath Length(miles)Path Loss(dB)1112211831214124512610 13215 13520 13825 14030 14135 143Table 4.   Receiver Sensitivity for the TRACER 6420Delivered BandwidthReceiver Sensitivity8 Channels -87 dBm4 Channels -90 dBm2 Channels -93 dBmShould an interferer be present nearby, three software selectable band plans are provided for frequency agility. Changing the TRACER 6420 band plan does not require additional components, or opening of the radio. See > RF Link Configuration > RF Band Plan on page 53 for additional details.
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 20 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A6. ANTENNA INFORMATIONThe overall wireless system is directly affected by the antenna selection and installation, discussed in the following sections.Antenna AlignmentWith line-of-sight microwave communications, optimum system performance requires that the transmitting and receiving antennas are properly aligned. This ensures maximum received signal power at each receiver. Antenna alignment must be achieved in both azimuth (along a horizontal plane) and elevation (along a vertical plane). By ensuring maximum received signal strength, a received signal strength indicator (RSSI) helps the equipment installer to determine when alignment is maximized. TRACER RSSI Test PointsRSSI for the TRACER 6420 system is provided through the VT100 terminal menus accessed through the RS-232 interface, and it is presented as a series of bars indicating signal strength. More bars means more RSSI, which ensures greater received signal strength and better link performance.If both the local and remote end of the system are operational, the remote TRACER 6420 receive power can be viewed from the local TRACER 6420 VT100 terminal menu interface.An RSSI test point, located on the front panel, provides a DC voltage level (relative to the GND test point) that corresponds to the amount of signal being received from the far end's transmitter. The voltage at this test point can vary from approximately 0 to 5 VDC. An RSSI calibration sheet is shipped with the system to provide the installer a cross-reference between actual received signal level (in dBm) and RSSI voltage. This sheet is useful for verifying link budget calculations and ensuring proper equipment installation.Antenna Beam PatternsDirectly related to the subject of antenna alignment is the topic of antenna beam patterns. Antennas used with the TRACER 6420 system have a particular beam shape, determined in part by the physical construction and geometry of the antenna. The antenna beam patterns are characterized by a dominant main lobe, which is the preferred lobe to use for point-to-point communications, and several side lobes, as shown in Figure 2. When setting up a microwave link, antenna alignment is nothing more than steering the main lobes of both antennas until the main lobe of one transmitter is centered on the receiving element of the receiving antenna.Verify the antenna installation meets all regulations specified in the National Electric Code (NEC) Article 810.
TRACER 6420 System Manual Section 2  Microwave Path Engineering Basics612806420L1-1A Copyright © 2005 ADTRAN, Inc. 21Figure 2.  Typical Antenna Beam PatternAntennas are also designed to radiate RF energy efficiently for a specific range of frequencies. Please consult the data sheet for your particular antenna make and model to ensure that it is specified to operate in the 5725 MHz to 5850 MHz frequency band for the TRACER 6420 system.Fresnel Zones, Earth Curvature, and Antenna HeightsFresnel zones correspond to regions in the microwave path where reflections of the intended signal occur and combine in both constructive and destructive manners with the main signal, thereby either enhancing or reducing the net power at the receiver.In general, the odd numbered Fresnel zones (1, 3, 5, ...) add constructively at the receiver, while the even numbered Fresnel zones (2, 4, 6, ...) add destructively at the receiver.The first Fresnel zone corresponds to the main lobe, 60% of which must be free of physical obstructions for the path calculations to be valid. Since the main lobe contains the vast majority of the microwave energy, this zone is typically used to determine proper antenna heights when placing antennas on towers or buildings.The curvature of the Earth becomes a legitimate obstruction for path lengths of 7 miles or greater, and must also be accounted for when determining minimum antenna heights.The aggregate expression for minimum antenna height that incorporates both the 60% first Fresnel zone and the Earth’s curvature is given bywhere f is in GHz and d is in miles.main lobeside lobesh72.1d4f-----0.125d2+= (feet)
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 22 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ATable 5 tabulates minimum antenna heights for given path lengths.Table 5.   Minimum Antenna Height for Given Path Lengths Path Length(miles)Min. Antenna Height(ft)22243264185010 6014 8116 9218 10420 11722 13124 14526 16128 17730 19432 21334 23236 252
TRACER 6420 System Manual Section 2  Microwave Path Engineering Basics612806420L1-1A Copyright © 2005 ADTRAN, Inc. 237. OTHER CONSIDERATIONSPath AvailabilityThe path availability of a wireless link is a metric that expresses the fractional amount of time a link is available over some fixed amount of time, and depends on several factors. Path availability is expressed aswhere the parameters areaterrain factor bclimate factor fcarrier frequency (GHz) dpath length (miles) Ffade margin (dB)Terrain Factor (a)The terrain factor is a quantity that compensates the link availability for different types of terrain. Generally speaking, the smoother an area's terrain is, the less availability a wireless link running over that terrain will have, primarily due to multipath reflections. In contrast, secondary microwave signals will be randomly dispersed over rough terrain and will not interfere with the main signal lobe as badly as in the smooth terrain case. The terrain factor values normally used are listed below:Climate Factor (b)The climate factor is a quantity that compensates the link availability for different types of climates (weather). In general, microwave links operating in areas with high humidity will have less availability than those in arid areas, primarily because water is a dispersive mechanism to microwave energy and causes the main signal lobe to refract and disperse away from the receiver location. The climate factor values normally used are listed below:Terrain Terrain Factor DescriptionSmooth 4water, flat desertAverage 1moderate roughnessMountainous 1/4 very rough, mountainousClimate Climate Factor DescriptionVery Dry 1/8 desert regionsTemperate 1/4 mainland, interior regionHumid 1/2 humid and coastal regionsA12.5106–×()abfd310 F10⁄–()–[]100%×=(%)
Section 2  Microwave Path Engineering Basics TRACER 6420 System Manual 24 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  25ENGINEERING GUIDELINESProvides information to assist network designers with incorporating the TRACER 6420 system into their networks.CONTENTSEquipment Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Power Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Reviewing the Front Panel Design  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RSSI Monitoring Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   26Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   27AUX RS232 Interface (RJ-45). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27CRAFT Port (DB-9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   28Reviewing the TRACER 6420 Rear Panel Design   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28MGMT 10/100BaseT/TX Connection (RJ-48C)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   29DC Power Connection (Plug-In Terminal Block) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30Fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30Alarm Contacts (Plug-In Terminal Block)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30Antenna Interface (N-Type connector) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30Network Module Interfaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314xT1 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   31Quad Ethernet Switch Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31At-A-Glance Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32LIST OF FIGURESFigure 1. TRACER 6420 Front Panel Layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   26Figure 2. TRACER 6420 Rear Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   29LIST OF TABLESTable 1. TRACER 6420 Front Panel Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Table 2. TRACER 6420 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Table 3. AUX RS232 Pinout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 4. CRAFT Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 5. Null-Modem Pinout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 6. Rear Panel Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 7. MGMT 10/100BaseT/TX Interface Pinout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 8. DC Power Connector Pinout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Table 9. Alarm Contact Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Table 10. 4xT1 Module RJ-45 Connector Pinout   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 11. Quad Ethernet Switch RJ-48C Connector Pinout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 12. At-A-Glance Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Section 3  Engineering Guidelines TRACER 6420 System Manual 26 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. EQUIPMENT DIMENSIONSThe TRACER 6420 integrated radio is 17.2” W, 11.4” D, and 1.7” H, weighs 7 lbs, and can be used in rackmount configurations. 2. POWER REQUIREMENTSThe TRACER 6420 radio has a maximum power consumption of 25 W and a maximum current draw of 1.2 A (at 21 VDC).3. REVIEWING THE FRONT PANEL DESIGNThe front panel contains an RSSI monitoring interface, a GND interface for reference with RSSI, a TEST interface for viewing the QPSK constellation, a DB-9 CRAFT port for management and configuration, an AUX RS232 interface (RJ-45) that provides an end-to-end serial port interface (at 9600 bps), and status LEDs to provide visual information about the TRACER 6420 system. Figure 1 identifies the various interfaces and the LEDs, and Table 1 provides a brief description of each interface.Figure 1.  TRACER 6420 Front Panel LayoutRSSI Monitoring InterfaceThe RSSI voltage is a function of the signal strength at the receiver and is used to measure the received signal strength. RSSI varies from approximately 0 to 5 VDC. An RSSI calibration sheet is shipped with the system to provide the installer a cross-reference between actual received signal level (in dBm) and RSSI voltage. This sheet is useful for verifying link budget calculations and ensuring proper equipment installation.Table 1.  TRACER 6420 Front Panel Description1 1 Detailed discussions (including pinouts) of front panel components (where applicable) follow the table.Name Connector DescriptionARSSI bantam DC voltage indicating strength of the received signal at the antennaBStatus LEDs N/A Visual status information about the systemCGND bantam Ground reference for the RSSI interfaceDTEST 3 conductor stereo jack QPSK constellation (when connected to oscilloscope)EAUX RS232 RJ-45 Serial interface for a 9600 bps connection between the local and remote systems over the RF linkFCRAFT PORT DB-9 RS-232 interface for connection to a VT100 terminal or PC with terminal emulation softwareTRACER 6200BCADE  F
TRACER 6420 System Manual Section 3  Engineering Guidelines612806420L1-1A Copyright © 2005 ADTRAN, Inc. 27Front Panel LEDsWith the TRACER powered-on, the front panel LEDs provide visual information about the status of the system. Table 2 provides detailed information about the LEDs.AUX RS232 Interface (RJ-45)The AUX RS232 interface provides a female RJ-45 terminal connection (wired as a DCE interface), which is used for a 9600 bps point-to-point connection between the local and remote systems (over the RF link). Table 3 shows the pinout.Table 2.  TRACER 6420 LEDs For these LEDs... This color light... Indicates that...PWRGreen (solid) the TRACER is connected to a power source.Off the TRACER is not currently powered up.TST Amber (flashes once)power-up self-test is in progress. If the LED continuously flashesor remains on (solid) after 10 seconds, the unit has failedself-test.STATUS MOD1 and MOD2Green  the module is installed and functioning properly.Red (solid) a port on the installed module is currently in alarm.Off no module occupies the slot.PLAN AGreen (solid) the TRACER is transmitting on Frequency Plan A.Off the TRACER is not transmitting on Frequency Plan A.PLAN BGreen (solid) the TRACER is transmitting on Frequency Plan B.Off the TRACER is not transmitting on Frequency Plan B.RF LO Red (solid) the RSSI level is below suggested minimum threshold (approximately 10 dBm above the minimum receive sensitivity).RF DWN Red (solid) there is a communication problem between the local and remote TRACERs.Table 3.  AUX RS232 Pinout Pin Name Source Description1 GND Common Signal ground2 RTS Attached Equipment Request to send (unused)3 TXDATA Attached Equipment Transmit data (from attached equipment)4 DSR TRACER Data set ready5 RXDATA TRACER Received data (to attached equipment)6 CTS TRACER Clear to send7 DTR Attached Equipment Data terminal ready (unused)8 CD TRACER Carrier detect
Section 3  Engineering Guidelines TRACER 6420 System Manual 28 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ACRAFT Port (DB-9) The CRAFT connector provides a female DB-9 terminal connection (wired as a DCE interface), which is used for terminal access to the TRACER system. Table 4 shows the pinout. A null modem cable is necessary for connecting the CRAFT port to a modem for remote dial-up access. Table 5 shows the pinout for a null modem cable.4. REVIEWING THE TRACER 6420 REAR PANEL DESIGNFigure 2 on page 29 identifies the features of the TRACER rear panel, and Table 6 on page 29 provides a brief description of each interface. Table 4.  CRAFT Pinout Pin Name Source Description1CD TRACER Carrier detect2RXDATATRACER Received data (to attached equipment)3 TXDATA Attached Equipment Transmit data (from attached equipment)4 DTR Attached Equipment Data terminal ready (unused)5 GND Common Signal ground6DSR TRACER Data set ready7 RTS Attached Equipment Request to send (unused)8CTS TRACER Clear to send9RI TRACER Ring indicator (unused)Table 5.  Null-Modem Pinout ModemPinTRACER 6420Pin1 (CD) unconnected2 (RXD) 3 (TXD)3 (TXD) 2 (RXD)4 (DTR) 6 (DSR)5 (GND) 5 (GND)6 (DSR) 4 (DTR)7 (RTS) 8 (CTS)8 (CTS) 7 (RTS)9 (RI) unconnected
TRACER 6420 System Manual Section 3  Engineering Guidelines612806420L1-1A Copyright © 2005 ADTRAN, Inc. 29Figure 2.  TRACER 6420 Rear PanelMGMT 10/100BaseT/TX Connection (RJ-48C)The physical Ethernet interface is provided by a single RJ-48C jack (labeled MGMT) that delivers 10/100BaseT/TX for LAN connectivity. The MGMT port is used for Telnet, SNMP, and TFTP access and is not a router interface. The MGMT port has a green LINK LED to indicate a valid link and an amber ACT LED that flashes with data activity on the interface. Table 7 shows the pinout.Table 6.  Rear Panel Description11 Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.Name Connector DescriptionANetwork Module SlotsN/A Dual network module slots for system flexibility (shown with a single 4xT1 Module and a Quad Ethernet Switch Module installed)BMGMT RJ-48C 10/100BaseT/TX Ethernet interface for Telnet accessCDC Power Terminal Block 21-60 VDC power source connection (either polarity referenced to ground)DFuse N/A 2A, 250 V, 2” slo-blo fuseEAlarm Terminal block External alarm monitoring system connectionFAntenna N-Type (female) Antenna feedline cable connectionGGround Lug N/A Earth ground connectionTable 7.  MGMT 10/100BaseT/TX Interface Pinout Pin Name Description1TX1 Transmit positive2TX2 Transmit negative3RX1 Receive positive4,5 —Unused6RX2 Receive negative7, 8 —UnusedAntennaDC PowerConnection ConnectorGroundLugFuse AlarmContactsCFBEDGEthernetInterfaceNetworkModule SlotsA
Section 3  Engineering Guidelines TRACER 6420 System Manual 30 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ADC Power Connection (Plug-In Terminal Block)The TRACER 6420 can operate from a supply between 21 and 60 VDC, with either polarity referenced to ground, and consumes less than 25 W. Power supplies should be able to provide up to 25 W at the selected voltage. Current required (in Amps) is determined by dividing the power consumed (in Watts) by the applied voltage (in Volts). For example, at 48 V, TRACER 6420 would draw approximately 0.52A  (25 W/48 V).FuseThe fuse holder, accessible from the rear panel of the TRACER 6420, accepts a generic 2 A, 250 V, 2-inch slow-blo fuse.Alarm Contacts (Plug-In Terminal Block)An RF link down condition is indicated with both normally open (NO) and normally closed (NC) alarm contacts on the rear panel of the TRACER 6420 system. In normal operation, the NC contact is electrically connected to the common contact (COM) and the NO contact is isolated. When the RF link drops, the NC contact becomes isolated and the NO is electrically connected to COM. This allows RF down conditions to be reported to external alarm monitoring systems. Table 9 provides the Alarm Contact pinout.Antenna Interface (N-Type connector)The ANTENNA interface (N-Type connector) connects to the customer-supplied antenna using standard antenna feedline cable. When determining the cable specifications for your application, refer to Section 2, Microwave Path Engineering Basics (System Losses (L) on page 17) for a discussion on cable length and loss factors.Table 8.  DC Power Connector Pinout Pin Name Description1+/– Voltage2GND GroundTable 9.  Alarm Contact Connector Pinout Pin Name Description1 COM Common Contact2 NO Normally-Open Contact3 NC Normally-Closed Contact
TRACER 6420 System Manual Section 3  Engineering Guidelines612806420L1-1A Copyright © 2005 ADTRAN, Inc. 315. NETWORK MODULE INTERFACES4xT1 ModuleThe 4xT1 Network Module has four T1 interfaces (through four RJ-45 ports) that provide the following functions:• ANSI T1.403 and AT&T® 54016 and 62411 compliant• AMI or B8ZS coding• Extended Super Frame (ESF) and Super Frame (SF) framing support• Manual line build out• Network performance monitoring and reporting• Test loopbacks (both Line and Link)Table 10 provides the RJ-45 interface pinout for the 4xT1 Network Module. Quad Ethernet Switch ModuleThe Quad Ethernet Switch Module has four 10/100BaseTX interfaces (through four RJ-48C ports) that provide the following functions:• IEEE 802.3 and 802.3u compliant• Auto MDI/MDIX crossover• Backpressure flow control on all full-duplex interfaces• Link and Activity LEDs for each portTable 10 provides the RJ-48C interface pinout for the Quad Ethernet Switch Module.Table 10.  4xT1 Module RJ-45 Connector Pinout Pin Name Description1 R Transmit data (ring) towards the network2 T Transmit data (tip) towards the network3, 6-8 UNUSED —4 R1 Receive data (ring) toward the network5 T1 Receive data (tip) from the networkTable 11.  Quad Ethernet Switch RJ-48C Connector Pinout Pin Name Source Description1 RX1 Attached Equipment Receive Positive2 RX2 Attached Equipment Receive Negative3 TX1 Module Transmit Positive4, 5 UNUSED N/A —6 TX2 Module Transmit Negative7, 8 UNUSED N/A —
Section 3  Engineering Guidelines TRACER 6420 System Manual 32 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A6. AT-A-GLANCE SPECIFICATIONSTable 12 contains a list of specifications for the TRACER 6420 system.Table 12.  At-A-Glance Specifications  Hardware Description SpecificationTransmitterOutput Power +20 dBm, maxFrequency Range 5725 to 5850 MHz ReceiverReceive Level, Minimum-88 dBm @ 8xT1 -91 dBm @ 4xT1 -94 dBm @ 2xT1Receive Level, Maximum -30 dBm Receive Level, Nominal -55 dBm Frequency PlanPlan AChannel Plan1 Tx 5.744 GHz, Rx 5.824 GHz 2 Tx 5.747 GHz, Rx 5.827 GHz 3 Tx 5.751 GHz, Rx 5.831 GHz Plan BChannel Plan1 Tx 5.824 GHz, Rx 5.744 GHz 2 Tx 5.827 GHz, Rx 5.747 GHz 3 Tx 5.831 GHz, Rx 5.751 GHz Data EncryptionEncryption Type Symmetric Triple-DES (3DES)User InterfacePanel Alarm LEDsDiagnostics RF link diagnostics and error history, transmit and receive packets historyTest Points RSSI, Ground (GND), and Test (QPSK Constellation)Alarms Normally Open (NO) and Normally Closed (NC)VT100 Terminal Menu Driven User Interface, Control of the Remote End, Event HistoryTelnet Access Menu Driven User Interface, Control of the Remote End, Event HistorySNMP  Standard MIB support (T1 and Ether-like MIBs); Enterprise MIB support (ADTRAN TRACER)
TRACER 6420 System Manual Section 3  Engineering Guidelines612806420L1-1A Copyright © 2005 ADTRAN, Inc. 33VT100 Terminal InterfaceData Rate 9600, 19200, 38400, 57600, 115200 bpsData Bits 8Parity NoneStop Bits 1Terminal Emulation VT100Mechanical and EnvironmentalOperating Temperature -25° C to 65° CSize 1.7” H x 17.2” W x 11.4” DHumidity 95%, Non-condensingWeight 7 lbsPowerInput Voltage 21 to 60 VDC, either polarity referenced to groundPower Consumption < 25 WConnector 2 pin terminal block (DC)Fuse 2 A, 250 V slow-blo fuse (2-inch)Network ModulesQuad T1 Module Connection four RJ-45 interfacesCapacity 4xT1 (ANSI T1.403, AT&T® 54016 and 62411)Line Code B8ZS (default), AMIAlarms AIS, Red, Yellow, BPVs, LOSQuad Ethernet Switch ModuleConnection four RJ-48C interfacesInterface Type four 10BaseT/100BaseTX interfaces with auto MDI/MIDX crossoverFlow Control Back-pressure flow control on half-duplex interfacesPause-frame flow control on full-duplex interfacesTable 12.  At-A-Glance Specifications  (Continued)Hardware Description Specification
Section 3  Engineering Guidelines TRACER 6420 System Manual 34 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  35NETWORK TURNUP PROCEDUREProvides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit.CONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Tools Required  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Unpack and Inspect the System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Contents of Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   36Customer Provides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   37Channel Selection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Grounding Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Supplying Power to the Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Installing Modules   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Instructions for Installing Network Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   41Connecting the Module Interfaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424xT1 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   42Quad Ethernet Switch Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42FIGURESFigure 1. 5.8 GHz Bandwidth Division. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   37Figure 2. 19-inch Rackmount Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   40Figure 3. 23-inch Rackmount Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   40Figure 4. TRACER 6420 Network Module Slot Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   41
Section 4  Network Turnup Procedure TRACER 6420 System Manual 36 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. INTRODUCTIONThis section discusses TRACER 6420 system installation.2. TOOLS REQUIREDThe tools required for TRACER 6420 installation are:• VT100 terminal or PC with terminal emulation software• RS-232 (DB-9 male for TRACER 6420) cable for connecting to terminal3. UNPACK AND INSPECT THE SYSTEMEach TRACER 6420 is shipped in its own cardboard shipping carton. Open each carton carefully and avoid deep penetration into the carton with sharp objects. After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier; then contact ADTRAN Customer Service (see Customer Service, Product Support Information, and Training information in the front of this manual).Contents of ShipmentYour shipment of the base unit includes the following items:• TRACER 6420 unit• RJ-45 to DB-9 connector (ADTRAN P/N 3196ADPT001) for connection to the AUX RS232 port• 6’ silver satin cable for • Rackmount brackets• Power and Alarm connectors• TRACER 6420 Documentation CDYour shipment of the Quad Ethernet Switch Module includes the following items:• Quad Ethernet Switch Module• Quad Ethernet Switch Module Quick Start GuideChanges or modifications not expressly approved by ADTRAN could void the user’s authority to operate the equipment.To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.This system MUST be installed by qualified service personnel in a Restricted Access Location.
TRACER 6420 System Manual Section 4  Network Turnup Procedure612806420L1-1A Copyright © 2005 ADTRAN, Inc. 37Your shipment of the 4xT1 Network Module includes the following items:• 4xT1 Network Module• 4xT1 Network Module Quick Start GuideCustomer ProvidesThe following items are necessary for the installation of the TRACER 6420 system and are not provided:• 21 to 60 VDC power source either polarity referenced to ground• DB-9 cable for VT100 access• T1 cables for connecting external equipment to the T1 interfaces (4xT1 Module only)• Ethernet cables for connected external equipment for the switch interfaces (Quad Ethernet Switch Module only)• Ethernet cable (for Telnet access)4. CHANNEL SELECTIONThe FCC has allocated 125 MHz of spectrum in the 5.8 GHz band where the TRACER 6420 operates. Figure 1 illustrates the bandwidth division. Figure 1.  5.8 GHz Bandwidth DivisionTo designate the utilization of the ISM bandwidth, there are two different channel plans, labeled A and B. The letter of each channel plan setting is preset by the factory and refers to the physical configuration of the diplexer filter inside the chassis. Each channel is then divided into three band plans (1, 2 or 3). The band plans must be the same for the local and remote TRACER 6420. For example, the transmitter at one end of the link will transmit in band plan 1 of channel A (the lower portion of the spectrum) and receive in band plan 1 of channel B (the upper portion). Consequently, the receiver at the other end should receive in band plan 1 of channel A (the lower portion) and transmit in band plan 1 of channel B (the upper portion).The letter of the channel plan (A or B) must be different on both ends and the number of the band plan (1, 2, or 3) must be the same on both ends. The default band plan configuration for the TRACER 6420 is band plan 1.The channel plan (A or B) of the unit may be changed in the field, if necessary, by rewiring the internal diplexer. Contact Technical Support for more information on this procedure.Channel A57445725 5787 58505747 5751MHz MHzBand plan 3Band plan 2Band plan 1Channel B5824 5827 5831Band plan 3Band plan 2Band plan 1
Section 4  Network Turnup Procedure TRACER 6420 System Manual 38 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A5. GROUNDING INSTRUCTIONSThe following paragraphs provide grounding instruction information from the Underwriters’ Laboratory UL60950 Standard for Safety of Information Technology Equipment Including Electrical Business Equipment, with revisions dated March 15, 2002.An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductors is to be installed as part of the circuit that supplies the product or system. Bare, covered, or insulated grounding conductors are acceptable. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes. The equipment grounding conductor is to be connected to ground at the service equipment.The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, and the equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.A supplementary equipment grounding conductor shall be installed between the product or system and ground that is in addition to the equipment grounding conductor in the power supply cord.The supplementary equipment grounding conductor shall not be smaller in size than the ungrounded branch-circuit supply conductors. The supplementary equipment grounding conductor shall be connected to the product at the terminal provided, and shall be connected to ground in a manner that will retain the ground connection when the product is unplugged from the receptacle. The connection to ground of the supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70. Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground.The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal and should be fastened to the grounding lug provided on the rear panel of the equipment. The ring terminal should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).The supplemental equipment grounding terminal is located on the rear panel of the TRACER 6420.
TRACER 6420 System Manual Section 4  Network Turnup Procedure612806420L1-1A Copyright © 2005 ADTRAN, Inc. 396. SUPPLYING POWER TO THE UNITThe TRACER 6420 can operate from a supply between 21 and 60 VDC, with either polarity referenced to ground. Power supplies should be able to provide up to 25 Watts at the selected voltage. A dual pin terminal plug accepts power at the rear panel of the unit, providing a voltage (+/–) and ground (GND) reference point.7. MOUNTING OPTIONSInstall the TRACER 6420 in a location that requires minimal antenna feedline length (the loss in this cable directly affects overall system performance). The TRACER 6420 is designed to be mounted in a rack. If multiple units are installed in one location, one half inch of spacing is recommended above and below the unit.The TRACER 6420 systems are 1U high, rack-mountable units which can be installed into 19- (see Figure 2) or 23-inch (see Figure 3 on page 40) equipment racks using the supplied rackmount brackets (3265498@B). Follow these steps to mount the TRACER 6420 into a rack:• This unit shall be installed in accordance with Article 400 and 364.8 of the NEC NFPA 70 when installed outside of a Restricted Access Location (i.e., central office, behind a locked door, service personnel only area).• Power to the TRACER 6420 DC system must be from a reliably grounded  21-60 VDC UL Listed or CSA Certified ITE Power Supply with outputs meeting LPS requirements.• A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the field wiring.Instructions for Rackmounting the TRACER 64201 Position the TRACER 6420 in a stationary equipment rack. This unit takes up 1U of space. To allow proper grounding, scrape the paint from the rack around the mounting holes where the TRACER 6420 will be positioned.2 Have someone else hold the unit in position as you install two mounting bolts through the unit’s brackets and into the equipment rack using a #2 Phillips screwdriver.Be careful not to compromise the stability of the equipment mounting rack when installing this product.
Section 4  Network Turnup Procedure TRACER 6420 System Manual 40 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AFigure 2.  19-inch Rackmount IllustrationFigure 3.  23-inch Rackmount IllustrationTRACER 6420TRACER 6420
TRACER 6420 System Manual Section 4  Network Turnup Procedure612806420L1-1A Copyright © 2005 ADTRAN, Inc. 418. INSTALLING MODULESFigure 4 shows the slot numbering designation as viewed from the rear of the TRACER 6420. The functionally identical option slots only accept TRACER network modules. Figure 4.  TRACER 6420 Network Module Slot DesignationInstructions for Installing Network ModulesIndividual access modules insert in the back of the chassis. Two Phillips-head screws hold the modules in place for added security. To install network modules, follow the steps outlined below.Access modules are intended to be serviced by qualified service personnel onlyElectronic modules can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded. Step Action1. Remove power from the unit.2. Slide the network module into the network slot until the module is firmly seated against the front of the chassis. 3. Secure the screws at both edges of the module.4. Connect the cables to the associated device(s).5. Restore power to the unit.MODULE 1 MODULE 2
Section 4  Network Turnup Procedure TRACER 6420 System Manual 42 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A9. CONNECTING THE MODULE INTERFACES4xT1 ModuleThe physical T1 interfaces are provided using four RJ-45 ports located on the module. Straight-through T1 interface cables can be used to interface to any standard T1 DTE device (not supplied).Quad Ethernet Switch ModuleThe physical Ethernet interfaces are provided using four RJ-48C jacks. Ethernet cables are not supplied with your shipment. Connect any standard Ethernet device to one of the switch ports located on the rear of the unit.T1 crossover cables are needed when connecting two TRACER 6420 T1 ports in back-to-back operation.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  43USER INTERFACE GUIDEProvides detailed descriptions of all menu options and configuration parameters available for the TRACER 6420.This section of the TRACER 6420 System Manual is designed for use by network administrators and others who will configure and provision the system. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions.CONTENTSNavigating the Terminal Menu   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Terminal Menu Window  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   45Navigating using the Keyboard Keys  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   46Menu and System Control  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Password Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   46Menu Descriptions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47> System Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   47> Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   49> System Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   50> RF Link Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   52> RF Link Performance History (Main Screen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   54> RF Link Performance History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54> RF Link Max/Min Received Power History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   55> RF Link Min/Max Received Signal Quality History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   56> Datapath Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   57> Ethernet Switch Module Configuration/Status/History (Main Screen) . . . . . . . . . . . . . . . . . . .   58> Ethernet Switch Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  58> Ethernet Switch Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   59> T1 Module Configuration/Status/History (Main Screen). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   60> T1x Status/Configuration/Loopback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   61> Management/Utilities (Main Screen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   65> Ping Utility  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   67> Firmware Upgrade Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   68FIGURESFigure 1. Main Menu Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   45Figure 2. TRACER 6420 System Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   47Figure 3. TRACER 6420 Main Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   49Figure 4. TRACER 6420 System Configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   50Figure 5. RF Link Configuration (With Optional Triple-DES Encryption). . . . . . . . . . . . . . . . . . . .   52Figure 6. 5.8 GHz Bandwidth Division. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   53Figure 7. RF Link Performance History (Main Screen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   54Figure 8. RF Link Performance History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   54Figure 9. RF Link Max/Min Received Power History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   55Figure 10. RF Link Min/Max Received Signal Quality History. . . . . . . . . . . . . . . . . . . . . . . . . . . . .   56Figure 11. Datapath Provisioning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   57Figure 12. Ethernet Switch Module Configuration/Status/History (Main Screen) . . . . . . . . . . . . . .   58Figure 13. Ethernet Switch Module Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   58
Section 5  User Interface Guide TRACER 6420 System Manual 44 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AFigure 14. Ethernet Switch Module Status  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   59Figure 15. T1 Module Configuration/Status/History (Main Screen). . . . . . . . . . . . . . . . . . . . . . . . .   60Figure 16. T1x Status/Configuration/Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   61Figure 17. T1 Local Link Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   62Figure 18. T1 Remote Link Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   63Figure 19. T1 Local Line Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   63Figure 20. T1 Remote Line Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   63Figure 21. T1x Link Performance History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   64Figure 22. Management/Utilities (Main Screen)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   65Figure 23. Management/SNMP Port Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   65Figure 24. Ping Utility  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   67Figure 25. Firmware Upgrade Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   68
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 451. NAVIGATING THE TERMINAL MENUThe TRACER 6420 menu system can be accessed with a VT100 compatible terminal that is connected to the CRAFT PORT (located on the front of the unit) and set to 9600 bits per second (default), 8 data bits, 1 stop bit, and no parity. Flow control on the serial interface should be configured to NONE for proper operation. Once a terminal is connected, press <Enter> to activate the login screen. The default password for the TRACER 6420 is password.Terminal Menu WindowThe TRACER 6420 uses a series of menu pages and a single Main menu page to access its many features. The Main menu page (see Figure 1) provides a link to all available configuration/status pages.Figure 1.  Main Menu ScreenAll TRACER 6420 passwords are case-sensitive.After connecting a VT100 terminal to the TRACER 6420, press <Ctrl + l> or <Ctrl + r> to redraw the current screen.
Section 5  User Interface Guide TRACER 6420 System Manual 46 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ANavigating using the Keyboard KeysYou can use various keystrokes to move through the terminal menu, to manage a terminal menu session, and to configure the system.Moving Through the Menus2. MENU AND SYSTEM CONTROLPassword ProtectionThe TRACER 6420 provides password protection of the menu interface (via Terminal or Telnet access). To do this... Press this key...Activate the Login screen (upon initial connection) Enter (twice)Refresh the screen <Ctrl + L><Ctrl + R>Exit the menu system and return to the login screen <Ctrl + Z>Close the Telnet session (or toggle the modem signalling to hang up an attached modem)<Ctrl + Z> (twice)Move up to select items Up Arrowp (Previous)Move down to select items Down Arrown (Next)Edit a selected menu item EnterSpacebarScroll through configuration parameters for a menu item SpacebarLeft/Right Arrowsp or n (Prev/Next)Cancel an edit EscapeReturn to Main menu page mBack out to previous menu page bLeft ArrowGo to System Status menu page sAll TRACER 6420 systems are shipped with a default password of password. (Passwords are case-sensitive.)
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 473. MENU DESCRIPTIONSThe remainder of this section describes the TRACER 6420 menus and submenus. > SYSTEM STATUSFigure 2 shows the TRACER 6420 System Status menu page. The status of major system components for both sides of the RF link are displayed, but no configuration can be performed from this view.Figure 2.  TRACER 6420 System StatusA. Elapsed TimeThe top of the TRACER 6420 System Status menu page displays the elapsed time the TRACER 6420 system has been operational since the last power reset.B. Module StatusA visual status of the current installed modules. The modules are listed in the order they are installed (Slot 1 on top and Slot 2 on the bottom).The menu structure of the TRACER 6420 system is depicted below as follows: > MENU PAGE > MENU PAGE > MENU SELECTION > MENU PAGE > MENU SELECTION > SUB-MENU4XT1 MODULE A visual status of current errors/alarms on the T1 interfaces (for both the local and remote systems) is provided on the TRACER 6420 System Status menu page. The four available T1 interfaces on the module (A through D) are only displayed if the interface is mapped in the DATAPATH PROVISIONING; a – is displayed for inactive, unmapped interfaces. The interface displayed in reverse highlight indicates an active error or alarm condition on the specified interface (A through D). Individual T1 status pages (accessible from the main menu) provide detailed T1 information.AElapsedTimeEFCRF StatusDRemoteFHRx PowerITx PowerITx Power JNavigation ReminderTRACERPlan FrequencyPlanStatusGGModule StatusBLocalFrequencyHRx PowerModule StatusStatus TRACERRx QualityRx QualityB
Section 5  User Interface Guide TRACER 6420 System Manual 48 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AC. RF StatusA graphical indicator of the RF links is located beneath the Elapsed Time display. The status of the received radio link is indicated as RF UP or RF DOWN for each direction. This RF status display corresponds to the RF DWN LED on the front of the unit.D. Remote System StatusThe right portion of the TRACER 6420 System Status menu page reports the status of the remote TRACER 6420 (the system across the wireless link from the active terminal). If the RF link is down in either direction, DATA NOT AVAILABLE is displayed in place of the remote system status information.E. Local System StatusThe left portion of the TRACER 6420 System Status menu page reports the status of the local TRACER 6420 (the system where the active terminal is attached). F. Frequency PlanDisplays the frequency plan (A or B) for the TRACER 6420 unit. For an operational TRACER 6420 system, you should have one A and one B frequency plan.G. Rx QualityDisplays an indicator of receive signal quality that is not necessarily related to receive signal level (for both the local and remote units) using a series of symbols (#). The more symbols displayed, the better the signal quality. This indicator is related to signal-to-noise ratio and features a colon (:) marker to indicate 10-6 bit error rate. This indicator is useful as a diagnostic tool to help identify interference, as the system may have high receive signal level and poor signal quality in situations where interference is an issue.H. Rx PowerDisplays the approximate receiver levels (for both the local and remote units) using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down in either direction and remote end data is unavailable, DATA NOT AVAILABLE is displayed in place of the symbols (#).I. Tx PowerDisplays the approximate transmitter levels (for both the local and remote units) using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down in either direction and remote end data is unavailable, DATA NOT AVAILABLE is displayed in place of the symbols (#).J. Navigation RemindersDisplays system navigation reminders. For more details on system navigation, refer to Navigating the Terminal Menu on page 45. QUAD ETHERNET SWITCH MODULE A visual status of current errors/alarms on the Ethernet interfaces (for both the local and remote systems) is provided on the TRACER 6420 System Status menu page. The configured data rate (on the Datapath Provisioning page) is displayed. Individual status notations for the available Ethernet interfaces are available through the Quad Ethernet Switch Module Status page.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 49> MAIN MENUThe TRACER 6420 Main menu page provides access to all other configuration/status pages.  Figure 3 shows the TRACER 6420 Main menu page.Figure 3.  TRACER 6420 Main MenuFrom the keyboard, use the up and down arrow keys to scroll through the available pages, or enter the number or letter of the selected page (to highlight the menu page) and press <Enter>.Installed Network Modules are displayed as menu options 5 (slot 1) and 6 (slot 2). Menu options for empty slots are not displayed.Press <m> from any menu in the TRACER 6420 menu structure to access the TRACER 6420 Main menu page.
Section 5  User Interface Guide TRACER 6420 System Manual 50 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> SYSTEM CONFIGURATIONFigure 4 shows the TRACER 6420 System Configuration menu page. System configuration parameters for both the local and remote TRACER 6420 units are available through this menu page.Figure 4.  TRACER 6420 System Configuration> SYSTEM CONFIGURATION > SITE NAMEProvides a user-defined alphanumeric description (up to 25 characters) for the TRACER 6420 system.> SYSTEM CONFIGURATION > SERIAL NUMBERDisplays the serial number for the unit. The serial number of the TRACER 6420 will automatically display in this field.> SYSTEM CONFIGURATION > SYSTEM TIMEDisplays the current time, including seconds. To edit this field, place the cursor on the field and press <Enter>. Then, enter the time in a 24-hour format (such as 23:00:00 for 11:00 pm). Press <Enter> when you are finished to accept the change. Press <1> from any menu in the TRACER 6420 menu structure to access the System Configuration menu page.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 51> SYSTEM CONFIGURATION > SYSTEM DATEDisplays the current date. To edit this field, place the cursor on the field and press <Enter>. Then, enter the date in mm-dd-yyyy format (for example, 10-30-1998). Press <Enter> when you are finished to accept the change.> SYSTEM CONFIGURATION > ELAPSED TIMEDisplays the length of time the TRACER 6420 system has been running. Each time you reset the system, this value resets to 0 days, 0 hours, 0 min, and 0 secs.> SYSTEM CONFIGURATION > CRAFT PORT BAUDSpecifies the baud rate of the port. Select either 9600 (default), 19200, 38400, 57600, or 115200 bps. If you are using the CRAFT port for modem access, ensure that the CRAFT port rate matches the modem baud rate.> SYSTEM CONFIGURATION > INACTIVITY LOGOUTThis option defines the amount of time in minutes the user may stay connected without any activity on the CRAFT port before the user is automatically logged out of the system. Select one of the following: 5 MIN, 10 MIN (default), 15 MIN, 30 MIN, 45 MIN, 60 MIN, or OFF.> SYSTEM CONFIGURATION > PASSWORDSets the password for password protection of the TRACER 6420 terminal interface. Enter up to 8 alphanumeric characters. The system password is case sensitive.> SYSTEM CONFIGURATION > PERFORMANCE STATS (CLEAR)Resets all system error counters for the TRACER 6420.> SYSTEM CONFIGURATION > FACTORY DEFAULTResets the system to the factory default settings. The configured IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY are not defaulted during a factory default. Changes to the INACTIVITY LOGOUT setting do not apply to the current session. All changes take affect at the next login to the system menus.The default password for the TRACER 6420 is password.The TOTAL ACTIVE CHANNELS parameter (on the Datapath Provisioning page) is reset to the factory default value (8). Performing a factory default on any system with less than 8 active channels will result in an RF link loss.
Section 5  User Interface Guide TRACER 6420 System Manual 52 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> RF LINK CONFIGURATIONFigure 5 shows the TRACER 6420 RF Link Configuration screen, which contains the transmit and receive power settings and band plan configuration for both the local and remote units.Figure 5.  RF Link Configuration> RF LINK CONFIGURATION > RX POWERDisplays the approximate receiver levels (for both the local and remote units) using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down in either direction and remote end data is unavailable, DATA NOT AVAILABLE displays in place of the symbols (#). This parameter is display only. > RF LINK CONFIGURATION > TX POWERAllows the transmitter levels (for both the local and remote units) to be adjusted. The current transmitter level is displayed using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down and remote end data is unavailable, DATA NOT AVAILABLE displays in place of the symbols (#). Pressing (+) on this field sets the TX POWER to full strength; pressing (-) reduces the TX POWER to the minimum. Reducing the transmitter power of the remote TRACER 6420 could cause the RF link to drop, requiring a technician to increase the transmit power by using the menu system at the remote site.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 53> RF LINK CONFIGURATION > RF BAND PLANSets the band plan for the TRACER 6420. Each channel is divided into three band plans (1, 2, or 3). Both local and remote TRACER 6420 must be configured with the same band plan (1, 2, or 3) but different channel plans (Plan A or Plan B). For example, the transmitter at one end of the link will transmit in band plan 1 of channel A (the lower portion of the spectrum) and receive in band plan 1 of channel B (the upper portion). Consequently, the receiver at the other end should receive in band plan 1 of channel A (the lower portion) and transmit in band plan 1 of channel B (the upper portion). (Refer to Figure 6 for the division.) The TRACER 6420 comes factory programmed with RF band plan set to Band 1.Figure 6.  5.8 GHz Bandwidth Division> RF LINK CONFIGURATION > LINK ENCRYPTIONThe TRACER 6420 provides Triple-DES (3DES) encryption of the data passed over the RF Link. When LINK ENCRYPTION is set to ENABLED, the TRACER 6420 sequentially applies the three keys entered in the SUBKEY 0, 1, and 2 fields to each 64-bit block of data transmitted over the RF link. The remote TRACER 6420 uses the same keys to decrypt each block. (The keys entered in the local and remote systems must be identical.)> RF LINK CONFIGURATION > SUBKEY (0-2)The TRACER 6420 provides 3DES encryption of the data passed over the RF Link. When LINK ENCRYPTION is set to ENABLED, the TRACER 6420 sequentially applies the three keys entered in the SUBKEY 0, 1, and 2 fields to each 64-bit block of data transmitted over the RF link. The remote TRACER 6420 uses the same keys to decrypt each block. (The keys entered in the local and remote systems must be identical.) Valid entries are numbers 0 through 9 and letters a through f. When changing RF band plans on installed links, change the remote end first. If the local end is changed first, remote configuration capability is lost. In the event the local end is changed first and the link is dropped, reset the local end to the previous setting to restore the link.Channel A57445725 5787 58505747 5751MHz MHzBand plan 3Band plan 2Band plan 1Channel B5824 5827 5831Band plan 3Band plan 2Band plan 1
Section 5  User Interface Guide TRACER 6420 System Manual 54 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> RF LINK PERFORMANCE HISTORY (MAIN SCREEN)Figure 7 shows the TRACER 6420 RF Link Performance History main screen, which contains the transmit and receive power settings and band plan configuration for both the local and remote units.Figure 7.  RF Link Performance History (Main Screen)> RF LINK PERFORMANCE HISTORYFigure 8 shows the TRACER 6420 main RF Link Performance History menu page, which displays detailed error statistics for the RF link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments. Figure 8.  RF Link Performance HistoryLink errors (LNK ERR) represent errored seconds across the wireless link, and are generally an indication of path or interference problems.7Days 24Hours(8 Hrs Displayedat a Time)
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 55The link error count and minimum received signal level for the most recent 24 hours are recorded in 15-minute increments and displayed on the right side of the page. The left side of the page displays the 24 hour totals for the most recent 7 days. > RF LINK MAX/MIN RECEIVED POWER HISTORYFigure 9 shows the TRACER 6420 RF Link Max/Min Received Power History page, which displays the available received power statistics from the system. Minimum and maximum received signal levels for the RF link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments are found on this screen.Figure 9.  RF Link Max/Min Received Power HistoryThe received power level (MIN and MAX) represents the minimum and maximum values of received signal level in a 24-hour or 15-minute increment and is displayed as a numerical value from 0 to 100, with 0 corresponding to 0 V of RSSI and 100 corresponding to 5 V RSSI.Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous 8 hours.The minimum receive power level is recorded to aid in troubleshooting problem RF links. Radio links with high MIN numbers and intermittent performance are probably experiencing interference, while links with low MIN numbers have improperly engineered paths or excess system losses. A system with MIN numbers varying widely could indicate fading, reflections, or an intermittent installation problem such as loose connectors, damaged coax or lightning arrestors, or water contaminated feedlines.Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous 8 hours.7Days 24Hours(8 Hrs Displayedat a Time)
Section 5  User Interface Guide TRACER 6420 System Manual 56 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> RF LINK MIN/MAX RECEIVED SIGNAL QUALITY HISTORYFigure 9 shows the TRACER 6420 RF Link Min/Max Received Signal Quality History menu page, which displays the available received signal quality statistics from the system. Minimum and maximum received signal quality levels for the RF link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments are found on this screen. Figure 10.  RF Link Min/Max Received Signal Quality HistoryThe received power quality level (MIN and MAX) represents the minimum and maximum values of received signal quality levels in a 24-hour or 15-minute increment and is displayed as a numerical value from 0 to 100, with 0 corresponding to poor signal quality and 100 corresponding to exceptional signal quality.Radio links with consistently high MIN and MAX numbers should not experience interference. Radio links with a large difference between MIN and MAX numbers could be experiencing fading, reflections, or intermittent interference or installation problems such as loose connectors, damaged coax cable, water contaminated feedlines, or damaged lightning arrestors. Radio links with consistently low MIN and MAX numbers may be experiencing interference, low receive levels, or installation problems. If this is the case, examine the RF link MIN/MAX received power history. High received power numbers with low received signal quality numbers indicate interference, while low received power numbers with low received signal quality numbers indicate low receive levels or installation problems.Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous 8 hours.7Days 24Hours(8 Hrs Displayed at a Time)
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 57> DATAPATH PROVISIONINGFigure 11 shows the Datapath Provisioning menu page, which displays the active network interfaces for the installed modules (from both the local and remote TRACER 6420 units). Figure 11.  Datapath Provisioning> DATAPATH PROVISIONING > TOTAL ACTIVE CHANNELSDefines the total number of channels active on the installed modules. Specify 2, 4, or 8 total active channels. After defining the total number of active channels, specify the actual active channels using the CHANNEL SELECTION menu.> DATAPATH PROVISIONING > MODULE 1/MODULE 2 CHANNELS(Read Only) Displays the total number of active channels on the installed module.> DATAPATH PROVISIONING > CHANNEL SELECTIONDefines the active channels (A, B, C, D) on each installed T1 module or the bandwidth dedicated to the Quad Ethernet Switch Module (in 2 Mbps steps). To activate a channel, press <Enter> and use the spacebar or arrow keys to cycle through the available channel combinations until the desired combination displays. Press <Enter> again to make the channel combination change. If the specified channel selection is not valid, the TRACER 6420 automatically corrects the configuration and populates the field with a valid selection.The number of active channels and the channel configuration on both the local and remote systems must match for the RF link to function properly. A discrepancy between the systems can result in unpredictable operation.The number of active channels and the channel configuration on both the local and remote systems must match for the RF link to function properly. A discrepancy between the systems can result in unpredictable operation.
Section 5  User Interface Guide TRACER 6420 System Manual 58 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> ETHERNET SWITCH MODULE CONFIGURATION/STATUS/HISTORY (MAIN SCREEN)Figure 12 shows the Ethernet Switch Module Configuration/Status/History main screen, which contains access to the status, configuration, testing, and performance history parameters for the selected Ethernet Switch module.Figure 12.  Ethernet Switch Module Configuration/Status/History (Main Screen)> ETHERNET SWITCH CONFIGURATIONFigure 13 shows the Ethernet Switch Module Configuration screen, which contains access to the port configuration options for the available Ethernet interfaces on the selected module.Figure 13.  Ethernet Switch Module ConfigurationThe following menus for the ETHERNET SWITCH CONFIGURATION apply to all four available Ethernet interfaces (1 through 4).
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 59>ETHERNET SWITCH CONFIGURATION > PORT XThe Quad Ethernet Switch Module provides the capability to individually disable interfaces on the module. Selecting DISABLE from the PORT X menu disables the port, stopping all data passing through the interface.>ETHERNET SWITCH CONFIGURATION > SPEED/DUPLEXDefines the speed and duplex for the selected Ethernet interface. Available options are: 100/FDX (100 Mbps with full duplex operation), 100/HDX (100 Mbps with half duplex operation), 10/FDX (10 Mbps with full duplex operation), and 10/HDX (10 Mbps with half duplex operation), and AUTO (automatically detects speed and duplex of the connection). The speed and duplex settings of the TRACER Ethernet port and the attached Ethernet equipment should be identical; if the TRACER is set to auto-negotiation the attached equipment should also be set for auto-negotiation.When the SPEED/DUPLEX is manually set, 802.3u auto-negotiation is disabled; the Ethernet equipment connected to the manual port must be manually set to the same speed/duplex settings. When set to AUTO, the actual negotiated speed and duplex of the system can be displayed on the Ethernet Switch Status page.> ETHERNET SWITCH STATUSFigure 14 shows the Ethernet Switch Module Status screen, which displays the current speed and duplex operation for each switch interface (on both the local and remote systems) as well as transmit and receive data statistics for the Ethernet interface (from both the local and remote TRACER 6420 systems) and RF link.Figure 14.  Ethernet Switch Module Status>ETHERNET SWITCH STATUS > TX PACKETSDisplays a counter of all data packets transmitted out the local and remote TRACER Ethernet interfaces. Use this data as an indicator for how many packets are being transmitted between the four Ethernet interfaces versus over the wireless link (WAN stats). The WAN statistics (Ethernet packets transmitted over the RF link) provide a quick way to determine Ethernet packet loss over the wireless link; the RX PACKETS on the local system should match the TX PACKETS on the remote side (and vice versa).
Section 5  User Interface Guide TRACER 6420 System Manual 60 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A>ETHERNET SWITCH STATUS > TX PACKETS DROPPEDDisplays a counter of all transmit data packets that were unable to be transmitted out the individual Ethernet interfaces (for both the local and remote TRACER units). Use this data as an indicator of congestion on the Ethernet network segments. Dropped packets on the WAN interface can indicate that the provisioned bandwidth for the switch module is insufficient.>ETHERNET SWITCH STATUS > RX PACKETSDisplays a counter of all data packets received on the local and remote TRACER Ethernet interfaces and WAN (RF link). Use this data as an indicator for how many packets are being received on the four Ethernet interfaces versus being received over the wireless link.>ETHERNET SWITCH STATUS > RX PACKETS DROPPEDDisplays a counter of all received data packets that were unable to be processed due to congestion inside the TRACER 6420 switch (for both the local and remote TRACER 6420 units). Use this data as an indicator of congestion inside the TRACER 6420 switch. >ETHERNET SWITCH STATUS > RX PACKET ERRORSDisplays a counter of all received data packets that are greater than or equal to 64 bytes in length and have either an FCS error or an alignment error (for both the local and remote TRACER units). RX PACKET ERRORS on the WAN interface (RF link) could indicate link degradation (due to interference, fading, etc.). > T1 MODULE CONFIGURATION/STATUS/HISTORY (MAIN SCREEN)Figure 15 shows the TRACER 6420 4xT1 Module Configuration main screen, which contains access to the status, configuration, testing, and performance history parameters for the selected T1 module.Figure 15.  T1 Module Configuration/Status/History (Main Screen)If the RF link goes down, some packet errors may display. Once the TRACER 6420 system recognizes the link is down (an active RF Low alarm), packet errors will NOT increment.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 61> T1X STATUS/CONFIGURATION/LOOPBACKFigure 16 on page 61 shows the T1x Status/Configuration/Loopback menu page, which displays a real-time graphical representation for the T1x link using data from both the local and remote TRACER 6420 units. T1x operational configuration parameters and testing functions are configured from this menu.Figure 16.  T1x Status/Configuration/Loopback>T1X STATUS/CONFIGURATION/LOOPBACK > T1X INTERFACE ALARMSDisplays any active alarms on the T1 link (reported from both the local and remote TRACER 6420 units). These alarms include Red, Blue/AIS, Yellow, LOS, and bipolar violations (BPV). Table 1 briefly describes these alarms. See Section 8, Troubleshooting Guide, for more information on these alarms.The following menus for the T1x Status/Configuration/Loopback apply to all four available T1 interfaces (A through D).Table 1.  T1 Interface Alarms RED Activates when no T1 signal is present from the connected T1 equipment. LOS is activated after receiving 192 consecutive zeros.BLUE/AIS Activates when an incoming remote alarm is received from a connected T1 device. An AIS signal is an unframed All One signal that replaces the normal traffic signal.YEL Activates when an incoming remote alarm is received from the T1 device indicating that a failure has occurred in the received direction.LOS Loss of sync occurs when the TRACER system cannot synchronize to the incoming T1 data stream.BPV Activates when the incoming T1 stream presents BPVs.
Section 5  User Interface Guide TRACER 6420 System Manual 62 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> T1X STATUS/CONFIGURATION/LOOPBACK > ALARM REPORTINGDetermines whether the TRACER 6420 unit will report active alarms. If set to DISABLED, no alarms will be displayed on this menu page. The ALARM REPORTING parameter is independently configured for the local and remote TRACER 6420 units. When set to DISABLED, the TRACER 6420 does not report active alarms via SNMP or the CRAFT port and the status LEDs are off. By default, alarm reporting is set to ENABLED.>T1X STATUS/CONFIGURATION/LOOPBACK > T1X LINE BUILD OUTConfigures the T1 for the appropriate line buildout, based on the distance to the T1 equipment. By default, the line buildout for the TRACER 6420 is 0 dB/133 FT.> T1X STATUS/CONFIGURATION/LOOPBACK > SIGNALINGConfigures the framing format for the T1 link for both the local and remote TRACER 6420 units. The TRACER 6420 transports T1 data across the link (as long as the T1 signal is properly timed). Configure the framing format (using the SIGNALING menu) to enable the TRACER 6420 to monitor incoming framing error events and indicate problems with the attached metallic service. The TRACER 6420 supports both extended superframe (ESF) and superframe (D4) framing formats. By default, the signaling method is set to ESF.> T1X STATUS/CONFIGURATION/LOOPBACK > LINE CODESets the line coding for the T1 link. The TRACER 6420 supports bipolar eight-zero substitution (B8ZS) and alternate mark inversion (AMI) line coding. By default, the line code is set to B8ZS.> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATEControls the loop status of the T1 link. Activates/deactivates loopback conditions for testing purposes.> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > NORMALDefines the T1 link as normal data transport mode; there are no active loopbacks.> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINK [LOCAL]Activates a loopback at the local TRACER 6420 T1 framer towards the remote end of the wireless link (see Figure 17). Use the local LINK loopback to loop the data transmitted from the remote end of the link back across the radio link to the remote end of the link. This loopback tests the integrity of the radio link and all the associated digital and RF hardware.Figure 17.  T1 Local Link Loopback
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 63> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINK [REMOTE]Activates a loopback at the remote TRACER 6420 T1 framer towards the local end of the wireless link (see Figure 18). Use the remote LINK loopback to loop the data transmitted from the local end of the link across the radio link to the local end of the link. This loopback tests the integrity of the radio link and all the associated digital and RF hardware.Figure 18.  T1 Remote Link Loopback> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINE [LOCAL]Activates a loopback at the local TRACER 6420 T1 framer towards the connected T1 equipment (see Figure 19). Use the local LINE loopback to test data path integrity from the local TRACER 6420 unit to the connected T1 equipment.Figure 19.  T1 Local Line Loopback> T1X STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINE [REMOTE]Activates a loopback at the remote TRACER 6420 T1 framer towards the connected T1 equipment at the remote end of the link (see Figure 20). Use the remote LINE loopback to test data path integrity from the remote TRACER 6420 unit to the T1 equipment connected at the remote end of the link.Figure 20.  T1 Remote Line Loopback
Section 5  User Interface Guide TRACER 6420 System Manual 64 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> T1X PERFORMANCE HISTORYFigure 21 on page 64 shows the T1x Performance History menu page, which displays detailed error statistics for the T1 link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour increments.Figure 21.  T1x Link Performance HistoryT1 performance data is presented as Errored Seconds (ES) and Severely Errored Seconds (SES) on the T1 interface. The following events qualify as an ES–AIS, LOS or LOF Alarm Second, a single BPV, excessive zero event, or a single parity bit. An SES is caused by an AIS, LOS or LOF Alarm Second, excessive BPVs, or framed parity bit errors causing a line bit error rate (BER) of 10-6.The error counts for the most recent 24 hours are recorded in 15-minute increments and displayed on the right side of the page. The left side of the page displays the 24-hour totals for the most recent 7 days.The following menus for the T1x Performance History apply to all four available T1 interfaces (A through D).Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous 8 hours.24 Hours7 Days(8 Hrs Displayed at a Time)
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 65> MANAGEMENT/UTILITIES (MAIN SCREEN)Figure 22 shows the TRACER 6420 Management/Utilities main screen, which contains access to the SNMP configuration, firmware upgrade options, and a ping utility for Ethernet testing.Figure 22.  Management/Utilities (Main Screen)> MANAGEMENT/SNMP PORT CONFIGURATIONFigure 23 shows the Management/SNMP Port Configuration menu page, which contains the configuration parameters for the 10/100BaseT MGMT Ethernet interface and SNMP configuration parameters (from both the local and remote TRACER 6420 units). Figure 23.  Management/SNMP Port Configuration
Section 5  User Interface Guide TRACER 6420 System Manual 66 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> MANAGEMENT/SNMP PORT CONFIGURATION > IP ADDRESSLists the address assigned to the 10/100BaseT MGMT Ethernet port. This address is in dotted decimal notation (four decimal numbers, each in the range of 0 to 255, separated by periods). This value is set to 192.168.0.1 by default. Obtain the correct IP address from your LAN administrator.> MANAGEMENT/SNMP PORT CONFIGURATION > NET MASKDefines which part of a destination IP address contains the network number. This address is in dotted decimal notation (four decimal numbers, each in the range of 0 to 255, separated by periods). This value is set to 255.255.255.0 by default. This part of the destination IP address is used along with the TRACER 6420 IP address to determine which nodes must be reached through the default IP gateway.> MANAGEMENT/SNMP PORT CONFIGURATION > DEFAULT GATEWAYDefines or changes the default gateway. You will need a default gateway if the LAN contains multiple segments. This address is in dotted decimal notation (four decimal numbers, each in the range of 0 to 255, separated by periods). This value is set to 192.168.0.254 by default. Contact your LAN administrator for the appropriate address.> MANAGEMENT/SNMP PORT CONFIGURATION > MAC ADDRESS(Read Only) Displays the system Ethernet Media Access Control (MAC) address.> MANAGEMENT/SNMP PORT CONFIGURATION > SNMP GET COMMUNITYDefines the community name for Get access (to poll the TRACER 6420 for status information). This value must match the Get name defined on the network management stations (NMS). Get access is read only access. The default name is public.> MANAGEMENT/SNMP PORT CONFIGURATION > SNMP PUT COMMUNITYDefines the community name for Set access (to change TRACER 6420 configuration parameters through SNMP). This value must match the Get or Set name defined on the NMS. The default name is private.> MANAGEMENT/SNMP PORT CONFIGURATION > SNMP TRAP COMMUNITYDefines the community name for trap destinations. This name must match the community name defined on the NMS. The default name is SNMP_trap.> MANAGEMENT/SNMP PORT CONFIGURATION > SNMP TRAP HOST #0 - #4Identifies the IP address in dotted decimal notation of the NMS for the TRACER 6420 to send SNMP traps to. Up to five trap destinations can be entered.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 67> PING UTILITYFigure 24 shows the Ping Utility menu page, which contains the parameters for performing a ping test out of the 10/100BaseT MGMT Ethernet interface. Figure 24.  Ping Utility> PING UTILITY > PING ADDRESSSpecifies the IP address to ping (in dotted decimal notation).> PING UTILITY > NUMBER OF PACKETSSpecifies the number of ping packets to send to the IP address specified in the PING ADDRESS field. The default value is 4, and the maximum value is 99.> PING UTILITY > PACKET SIZE (BYTES)Specifies the size (in bytes) of the data portion of the ping request. The default value is 64 bytes, and the maximum size is 1024 bytes.> PING UTILITY > TIMEOUT (MS)Specifies the time (in milliseconds) to wait for a ping reply before timing out. The default timeout is 3 seconds (3000 milliseconds), and the maximum value is 10 seconds (10000 milliseconds).> PING UTILITY > PING COMMANDUse this field to manually start (START) or stop (ABORT) a ping request, reset the ping statistics (RESET STATS), or return the ping configuration parameters to their default values (DEFAULT VALUES).
Section 5  User Interface Guide TRACER 6420 System Manual 68 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> PING UTILITY > DELAY(Read Only) Displays the round trip time (in milliseconds) of the ping request/reply of the current set of pings and provides the following information:>PING UTILITY > PACKETS(Read Only) Displays the packet statistics for the ping request/reply of the current set of pings and provides the following information:> FIRMWARE UPGRADE UTILITYFigure 25 shows the Firmware Upgrade Utility menu page, which contains the parameters for performing a firmware upgrade for the local and remote systems. Figure 25.  Firmware Upgrade UtilityMINIMUM The minimum round trip time of the ping request/reply for the current set of pings.MAXIMUM The maximum round trip time of the ping request/reply for the current set of pings.AVERAGE The average round trip time of the ping request/reply for the current set of pings.TXThe number of ping requests transmitted.RXThe number of ping replies received.LOST The number of ping requests that did not receive replies.
TRACER 6420 System Manual Section 5  User Interface Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 69> FIRMWARE UPGRADE UTILITY > FILE XFER METHODLists the available transfer methods for updating the TRACER 6420 system. The following selections are available:> FIRMWARE UPGRADE UTILITY > TFTP SERVER(Available for TFTP transfers only.) Configures the IP address of the TFTP server on which the update file resides. The TRACER 6420 uses this field to locate the network TFTP server and request the file transfer.> FIRMWARE UPGRADE UTILITY > TFTP FILENAME(Available for TFTP transfers only.) Specifies the name of the update file to retrieve from the TFTP server. Enter the full filename for the file. Some TFTP servers require the full path name for any file not located in the default directory. Refer to the TFTP software documentation for more details.> FIRMWARE UPGRADE UTILITY > UPGRADE DESTINATIONSpecify the unit to upgrade. The following options are available:> FIRMWARE UPGRADE UTILITY > COMMANDUse this command to start (START) or stop (ABORT) a firmware upgrade. For XMODEM updates, cancel the process via the terminal emulation software (consult your documentation for the information on how to do this). For TFTP updates, you can cancel the process by selecting ABORT from this field.> FIRMWARE UPGRADE UTILITY > LOCAL CURRENT STATUS(Available for TFTP updates only.) Indicates progress or problems encountered during the current upgrade of the local unit. The field displays IDLE if no update is in progress or when the update is successfully completed. At the end of a successful update, the contents of this field are copied into the Local Previous Status. For a detailed listing of these messages, please refer to DLP-5, Updating the Firmware Using TFTP.TFTP LOCAL MGMT PORT Upgrade the firmware using a trivial file transfer protocol (TFTP) server that is located on the same Ethernet network as the local system. TFTP transfers files by specifying an appropriate server address and filename.TFTP REMOTE MGMT PORT Upgrade the firmware using a TFTP server that is located on the same Ethernet network as the remote system. TFTP transfers files by specifying an appropriate server address and filename.XMODEM Upgrade the firmware using XMODEM software on a terminal or PC that is connected to the CRAFT interface of the local system. LOCAL IDU Upgrade the local system.REMOTE IDU Upgrade the remote system. When upgrading the remote system, the upgrade file is first loaded into the local system and then transferred over the wireless link to the remote system. The actual upgrade process is not started on the remote system until the entire upgrade file has been received.
Section 5  User Interface Guide TRACER 6420 System Manual 70 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A> FIRMWARE UPGRADE UTILITY > LOCAL PREVIOUS STATUS(Available for TFTP updates only.) Displays the status of the previous update of the local unit. Following a successful update, this field reads UPGRADE FINISHED SUCCESSFULLY. If an update was unsuccessful, the appropriate error message displays. Refer to DLP-5, Updating the Firmware Using TFTP, for more details on available error messages.> FIRMWARE UPGRADE UTILITY > REMOTE CURRENT STATUS(Available for TFTP updates only.) Indicates progress or problems encountered during the current upgrade of the remote unit. The field displays IDLE if no update is in progress or when the update is successfully completed. At the end of a successful update, the contents of this field are copied into the Local Previous Status. For a detailed listing of these messages, please refer to DLP-5, Updating the Firmware Using TFTP.> FIRMWARE UPGRADE UTILITY > REMOTE PREVIOUS STATUS(Available for TFTP updates only.) Displays the status of the previous update of the remote unit. Following a successful update, this field reads UPGRADE FINISHED SUCCESSFULLY. If an update was unsuccessful, the appropriate error message displays. Refer to DLP-5, Updating the Firmware Using TFTP, for more details on available error messages.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  71DETAIL LEVEL PROCEDURESDLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . 73DLP-2 Logging in to the TRACER 6420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  75DLP-3 Setting IP Parameters for the TRACER 6420  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77DLP-4 Verifying Communications Over an IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81DLP-5 Updating the Firmware Using TFTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  85DLP-6 Updating the Firmware Using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Section 6  Detail Level Procedures TRACER 6420 System Manual 72 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  73DLP-1 Connecting a VT100 Terminal or PC to the CRAFT PortIntroductionTRACER 6420 management and provisioning are facilitated by a series of intuitive menus that are accessible on a computer screen. Connecting either a VT100 terminal or a PC with terminal emulation software to the CRAFT interface (DB-9) on the front of the unit allows access to the menus and management features of the TRACER 6420. This section specifies how to connect the VT100 terminal or PC to the TRACER 6420.Prerequisite ProceduresThe TRACER 6420 must be powered up for terminal communication to function.Tools and Materials Required• A VT100 compatible terminal or PC with terminal emulation software• An appropriate cable to connect the TRACER 6420 to a terminalTo prevent electrical shock, do not install equipment in a wet location or during a lightning storm.Electronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.
Section 6 DLP-1  TRACER 6420 System Manual 74 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. Connecting a VT100 terminal to the TRACER 6420:2. Connecting a PC emulating a VT100 terminal to the TRACER 6420:Most PCs or laptops can run communications software that emulates a VT100 terminal. Examples include Windows programs such as Terminal® or Hyperterminal®. However, there are many other adequate, commercially available software packages which will allow your PC or laptop to emulate a VT100 terminal.You are now ready to log in to the TRACER 6420, as described in DLP-2, Logging in to the TRACER 6420.Perform one of the following steps:• Set the parameters of the VT100 terminal or PC to:– 9600 baud rate– 8 data bits– No parity– 1 stop bit– No flow control• If the terminal has a parallel setting, disable this setting and use the serial port. Using the CRAFT Port• Plug the DB-9 male end of the data cable into the TRACER 6420 CRAFT port on the front of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.• Set the parameters of the communications software to:– 9600 baud rate– 8 data bits– No parity– 1 stop bit– No flow control• Set the PC for direct connect on the appropriate com port (instead of dial up connection).Using the CRAFT Port• Plug the DB-9 male end of the data cable into the TRACER 6420 CRAFT port on the front of the unit. Make connection to the PC or laptop as appropriate for your equipment.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  75DLP-2 Logging in to the TRACER 6420IntroductionOnce you are connected to the TRACER 6420, you must log in to the system to gain access to the management and provisioning functions. This DLP assumes you are connected to the TRACER 6420 and provides specific steps for logging into the system.Prerequisite ProceduresComplete DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port.see To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.Electronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.After the IP parameters have been provisioned (see DLP-3, Setting IP Parameters for the TRACER 6420), you can also log in via Telnet.
Section 6 DLP-2  TRACER 6420 System Manual 76 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. After connecting to the system, press any key to display the LOGIN screen shown here. The flashing cursor at the LOGIN field indicates that a password must be entered.2. Enter the password for the TRACER 6420 at the LOGIN field. The manufacturer’s default password for the TRACER 6420 system is “password” in lowercase letters.3. Upon entering the correct password, the TRACER 6420 SYSTEM STATUS page is displayed as shown below.4. You are now logged in to the TRACER 6420 menu system.Perform the steps below in the order listed.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  77DLP-3 Setting IP Parameters for the TRACER 6420IntroductionIf the TRACER 6420 is connected to an IP network for Telnet, TFTP, or SNMP management, several IP parameters must be set for the unit to communicate with the network. These parameters are described in this DLP along with the procedures for setting them.Prerequisite ProceduresThis procedure assumes that the TRACER 6420 unit is connected to an IP network and is powered up.Please see your Network Administrator for the proper assignment of the following parameters: IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY.To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.Electronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.
Section 6 DLP-3  TRACER 6420 System Manual 78 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. Log in to the system with maximum rights (details are in DLP-2).2. Press M to activate the Main menu page. From the Main menu page, press 7 to select MANAGEMENT/UTILITIES.3. From the MANAGEMENT/UTILITIES page, select the MANAGEMENT/SNMP PORT CONFIGURATION option and press <Enter>. Perform the steps below in the order listed.
TRACER 6420 System Manual Section 6 DLP-3 612806420L1-1A Copyright © 2005 ADTRAN, Inc. 794. From the Management/SNMP Configuration menu page, select the IP ADDRESS field and press <Enter>. Type the IP address provided by your network manager and press <Enter> to accept the change. Repeat the process for the SUBNET MASK and DEFAULT GATEWAY options. The TRACER 6420 is now available for Telnet access. Complete the steps outlined in DLP-4, Verifying Communications Over an IP LAN.
Section 6 DLP-3  TRACER 6420 System Manual 80 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A
612806420L1-1A  81DLP-4 Verifying Communications Over an IP LANIntroductionWhen the 10/100BaseT MGMT port is connected to a local area network (LAN), test steps must be performed on the TRACER 6420 to ensure that the unit is communicating properly over the network. This procedure outlines those steps.Prerequisite ProceduresBefore beginning this procedure, the unit should be physically connected to the LAN and the provisioning tasks detailed in  DLP-3, Setting IP Parameters for the TRACER 6420, should be complete.Tools and Materials Required• Access to a PC or other computer connected to the LANTo prevent electrical shock, do not install equipment in a wet location or during a lightning storm.Electronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.
Section 6 DLP-4  TRACER 6420 System Manual 82 612806420L1-1A1. Verify the TRACER 6420 IP address.If you do not already have the IP Address for the TRACER 6420, obtain it from the network administrator or manually check for the address on the MANAGEMENT/SNMP CONFIGURATION page. (Access the MANAGEMENT/SNMP CONFIGURATION page by pressing 7 and then 1 from the Main menu page.)2. Ping the TRACER 6420 unit from a remote computer on the network.Using a remote computer system connected to the LAN, perform an ICMP Ping on the IP Address of the TRACER 6420. Verify that the unit responds properly. If the TRACER 6420 fails to respond, try the following:• Verify that the proper IP Address, Subnet Mask, and Default Gateway are provisioned in the unit (see  DLP-3, Setting IP Parameters for the TRACER 6420, for details).• Verify that the TRACER 6420 is properly cabled into the LAN and that the Ethernet cable is properly seated in the RJ-45 jack on the rear of the unit. • If the TRACER 6420 is connected to a hub or other network device that provides a carrier sense light for each port, verify that the carrier sense light for the port to which the TRACER 6420 is connected is lit. If this light is not lit, check the cabling between the hub and the shelf. The connection may also be verified using the activity LED located on the rear of the unit (part of the 10/100BaseT MGMT RJ-45 connector).• Verify the IP Address, Subnet Mask, and Default Gateway on the remote computer system.• If none of these steps are successful, contact the LAN Administrator for assistance.Perform the following steps in the order listed.Refer to the computer system’s documentation if you are unsure how to perform a Ping command. Most computers running a networked version of Microsoft Windows™ or UNIX allow a Ping to be performed by typing ping <IP Address> at a command line prompt. Typically, the Ping program will respond by indicating that the remote IP Address has responded in a certain amount of time or that no response was received.Some versions of Ping will continue running until you explicitly tell them to stop. If the program does not terminate on its own, type <CTRL+C> to stop the program.
TRACER 6420 System Manual Section 6 DLP-4 612806420L1-1A 833. Telnet to the TRACER 6420.From the same computer used in the previous step, Telnet to the TRACER 6420 and verify that the Telnet session is properly opened. Once the Telnet session is established, press <CTRL+Z> to logout of the session and return to the Login screen. Pressing <CTRL + Z> again closes the Telnet session.Refer to the documentation of the computer system if you are unsure how to initiate a Telnet session. Most computers running a networked version of Microsoft Windows™ or UNIX initiate a Telnet session by typing telnet <IP Address> at a command line prompt. The Windows XP HyperTerminal program also provides a Telnet client. Telnet is a utility common on many local area networks that allows remote access to another computer or piece of equipment.
Section 6 DLP-4  TRACER 6420 System Manual 84 612806420L1-1A
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  85DLP-5 Updating the Firmware Using TFTPIntroductionThe TRACER 6420 supports firmware updates using TFTP or XMODEM. Use the 10/100BaseT MGMT Ethernet port and TFTP from a network server or XMODEM (if your Telnet client supports file transfers), or use XMODEM and the CRAFT interface. This DLP provides the steps for a successful firmware upgrade using the 10/100 BaseT MGMT Ethernet port and a TFTP server. (See DLP-6, Updating the Firmware Using XMODEM, for instructions on using XMODEM.)Tools and Materials Required• A PC with Telnet client software• A TFTP server accessible on the network To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.Electronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.
Section 6 DLP-5  TRACER 6420 System Manual 86 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. Connect to the TRACER 6420 using the 10/100BaseT MGMT interface.If you are not already connected to the unit’s 10/100BaseT MGMT port using Telnet client software, use the procedure in DLP-3, Setting IP Parameters for the TRACER 6420, to connect to the unit. 2. Press M to go to the Main menu page. 3. Select the MANAGEMENT/UTILITIES menu and press <Enter>.4. Select the FIRMWARE UPGRADE UTILITY menu and press <Enter>.5. Go to the FILE XFER METHOD menu and select TFTP. The TRACER 6420 can use a TFTP server connected to the same Ethernet network as the local unit or a TFTP server connected to the same Ethernet network as the remote unit. Make the appropriate selection for your setup (choices are TFTP-LOCAL MGMT PORT or TFTP-REMOTE MGMT PORT).6. Go to the TFTP SERVER field and enter the IP address of the network TFTP server.7. Go to the TFTP FILENAME field and enter the filename of the firmware. TRACER 6420 firmware files have a .bin extension. When specifying the filename, include the full path if the firmware file is not located in the TFTP default location. For example, to use a firmware file in the c:\firmware folder on your local machine, enter c:\firmware\myfirmware.bin into the TFTP FILENAME field.8. Select the UPGRADE DESTINATION. Using TFTP provides the capability to upgrade both sections of the local and remote units. Valid choices are LOCAL IDU and REMOTE IDU.View CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any errors encountered during the download.During the TFTP upload, the following status messages display in CURRENT UPDATE STATUS to indicate the progress of the upload:Perform the following steps in the order listed.IDLE No active firmware upgrade.IDU RESET Indicates the firmware file transfer to the IDU is complete and the system is rebooting to load the new firmware.UPGRADE ABORTED Indicates the firmware upgrade was manually aborted by selecting ABORT from the COMMAND field.CONTACTING TFTP SERVER Indicates communication with the TFTP network server is trying to be established with the specified server address in the TFTP SERVER IP ADDRESS field.REQUESTING TFTP OF FILENAMEIndicates the TRACER 6420 is requesting TFTP access to the given update filename and path. Please verify appropriate user rights are selected for the specified path.TFTP TRANSFER IN PROGRESSIndicates communication with the TFTP network server has been established and the update file is being transferred between the TRACER 6420 and the TFTP network server.UPGRADE IMAGE IS VALID Indicates that the system image was verified as a valid image for the specified update. Before the firmware upgrade begins, the TRACER 6420 verifies that the image is valid. If it is not valid for the system, UPGRADE IMAGE IS INVALID displays.
TRACER 6420 System Manual Section 6 DLP-5 612806420L1-1A Copyright © 2005 ADTRAN, Inc. 87UPGRADE IMAGE IS INVALID Indicates that the system image was not verified as a valid image for the specified update. Before the firmware upgrade begins, the TRACER 6420 verifies that the image is valid. If it is not valid for the system, UPGRADE IMAGE IS INVALID displays. WAITING FOR SC TRANSFER TO BEGINIndicates that the local system is waiting to transfer the firmware upgrade information to the remote system over the service channel. Service channel communications over the RF link allow a user connected to a local system to upgrade the firmware of a remote system. Before the remote system begins the firmware upgrade process, a complete copy of the new firmware image must be received and stored in the remote system. This is done automatically when the remote system is chosen from the UPGRADE DESTINATION field.RECEIVING SC TRANSFER Indicates that the system is receiving the firmware upgrade information from the remote system over the service channel. Service channel communications over the RF link allow a user connected to a local system to upgrade the firmware of a remote system. Before the remote system begins the firmware upgrade process, a complete copy of the new firmware image must be received and stored in the remote system. This is done automatically when the remote system is chosen from the UPGRADE DESTINATION field.READY TO BEGIN SENDING SC TRANSFERIndicates that the local system is ready to transfer the firmware upgrade information to the remote system over the service channel. Service channel communications over the RF link allow a user connected to a local system to upgrade the firmware of a remote system. Before the remote system begins the firmware upgrade process, a complete copy of the new firmware image must be received and stored in the remote system. This is done automatically when the remote system is chosen from the UPGRADE DESTINATION field.SENDING SC TRANSFER Indicates that the local system is sending the firmware upgrade information to the remote system over the service channel. Service channel communications over the RF link allow a user connected to a local system to upgrade the firmware of a remote system. Before the remote system begins the firmware upgrade process, a complete copy of the new firmware image must be received and stored in the remote system. This is done automatically when the remote system is chosen from the UPGRADE DESTINATION field.VERIFYING FLASH IMAGE Indicates that the system flash image is being verified as a valid image for the specified update. Before the new firmware is loaded into the local flash, the TRACER 6420 verifies that the flash image is valid for the new firmware. If it is not valid for the system, the firmware upgrade fails.ERASING FLASH Indicates that the system flash is being erased so the new firmware image can be loaded into the local flash. Before the new firmware is loaded into the local flash, the TRACER 6420 verifies that the flash image is valid for the new firmware. If it is not valid for the system, the firmware upgrade fails.PROGRAMMING FLASH Indicates that the new firmware image is being loaded into the local flash. Before the new firmware is loaded into the local flash, the TRACER 6420 verifies that the flash image is valid for the new firmware. If it is not valid for the system, the firmware upgrade fails.
Section 6 DLP-5  TRACER 6420 System Manual 88 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A9. When the update has successfully completed, IDLE displays in the CURRENT UPDATE STATUS field and UPGRADE FINISHED SUCCESSFULLY displays in the PREVIOUS UPDATE STATUS field.The TRACER 6420 will restart immediately and resume operation. During reset and initialization, the RF link between the units will not be operational.REQUIRED COMMUNICATIONS LINK IS DOWNIndicates that a remote system firmware upgrade cannot be completed due to a problem with either the RF link or the service channel. Before a firmware upgrade begins, the system verifies that communication between all required parts is operational. If this check fails, the firmware upgrade fails.UPGRADE FAILED Indicates that the firmware upgrade was unsuccessful.UPGRADE FINISHED SUCCESSFULLYIndicates that the firmware upgrade completed successfully and the new firmware should be loaded and running.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  89DLP-6 Updating the Firmware Using XMODEMIntroductionThe TRACER 6420 supports firmware updates of the local and remote systems using TFTP or XMODEM. Use the 10/100BaseT MGMT port and TFTP from a network server or XMODEM (if your Telnet client supports file transfers), or use XMODEM and the CRAFT interface. This procedure outlines the steps for a successful firmware upgrade using the CRAFT interface and XMODEM software. The same XMODEM steps apply for file transfers through your Telnet client (refer to your Telnet client documentation for more details on file transfer specifics). (See DLP-5, Updating the Firmware Using TFTP, for instructions on using TFTP.)Tools and Materials Required• VT100 terminal or PC with VT100 terminal emulation software• XMODEM softwareTo prevent electrical shock, do not install equipment in a wet location or during a lightning stormElectronic equipment can be damaged by static electrical discharge. Before handling it, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.
Section 6 DLP-6  TRACER 6420 System Manual 90 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. Connect to the TRACER 6420 using the front panel DB-9 CRAFT interface.If you are not already connected to the unit’s CRAFT interface (either with a VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port. Connecting to the CRAFT interface limits the upgrade procedure to XMODEM only.2. Log in to the unit (see DLP-2, Logging in to the TRACER 6420 for details).3. Press M to go to the Main menu page. 4. Select the MANAGEMENT/UTILITIES menu and press <Enter>.5. Select the FIRMWARE UPGRADE UTILITY menu and press <Enter>.6. Go to the FILE XFER METHOD menu and select XMODEM.7. Select the UPGRADE DESTINATION. (Valid selections for XMODEM are LOCAL IDU and LOCAL ODU).8. View CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any errors encountered during the download.9. Select START from the COMMAND menu to start the update. When the TRACER 6420 is ready to receive the XMODEM upload, the menu screen will clear and display XMODEM waiting for start....<Ctrl-X> twice to Cancel. If this does not appear, please review the steps above for possible configuration errors.10. From the terminal emulation software, begin the XMODEM upload by using the appropriate command sequence. This may take several minutes.If necessary, refer to the terminal emulation software documentation for help. Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN. Otherwise, the update will not complete successfully. Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of the TRACER 6420 will be inoperable from the CRAFT interface. You can cancel the update at any time within the terminal emulation software. (Please consult the documentation provided by the terminal emulation software to determine how to do this).11. When the update has successfully completed, IDLE displays in the CURRENT UPDATE STATUS field and UPGRADE FINISHED SUCCESSFULLY displays in the PREVIOUS UPDATE STATUS field.The TRACER 6420 will restart immediately and resume operation. During reset and initialization, the RF link between the units will not be operational.Alternatively, if the unit is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. By using the 10/100BaseT MGMT port, the TRACER 6420 may be quickly upgraded using TFTP, provided there is a TFTP server on the local network. (See DLP-5, Updating the Firmware Using TFTP for more details.)Perform the following steps in the order listed.
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  91MIBSProvides a listing of SNMP Management Information Bases (MIBs) supported by the TRACER 6420. Traps supported for each MIB are also listed.CONTENTSMIBs Supported by the TRACER 6420  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92MIB Compilation Order   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Traps Supported by the TRACER 6420   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93MIB Variables Supported by the TRACER 6420   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95TABLESTable 1. MIBs Supported by the TRACER 6420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Table 2. MIB Compilation Order  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Table 3. Traps Supported by the TRACER 6420  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Table 4. MIB Variables for ad.mi2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Table 5. MIB Variables for ads1.mib  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96Table 6. MIB Variables for TRACER.mib   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Section 7  MIBs TRACER 6420 System Manual 92 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. MIBS SUPPORTED BY THE TRACER 6420Table 1 lists the MIBs supported by the TRACER 6420.2. MIB COMPILATION ORDERMIBs are compiled in the order shown in Table 2.Table 1.  MIBs Supported by the TRACER 6420rfc2495.mib Standard – DS1 and E1 Interface Typesrfc2863.mib IF MIB – updated MIB IIrfc3418.mib SNMPv2 MIBrfc3595.mib PerfHist-TC-MIB needed for RFC 2495rfc3635.mib EtherLike MIBadtran.mib ADTRAN product MIB needed to locate the ADTRAN specific MIBs on the MIB node treeianaif.mib IF MIB needed for RFC 2495ads1.mib ADTRAN DS1 MIBtracer.mib TRACER Modular MIBSNMPv2-SMI, SNMPv2-TC, and SNMPv2-CONF are not compiled, but the paths to these files are required by your MIB compiler during setup. Table 2.  MIB Compilation Orderrfc3418.mibianaif.mibrfc2863.mibrfc3593.mibrfc3635.mibrfc2495.mibadtran.mibads1.mibtracer.mib
TRACER 6420 System Manual Section 7  MIBs612806420L1-1A Copyright © 2005 ADTRAN, Inc. 933. TRAPS SUPPORTED BY THE TRACER 6420The TRACER 6420 supports the traps described in Table 3.Table 3.  Traps Supported by the TRACER 6420 MIB Trap This trap indicates that....TRACER.mib adTRACERColdStart the unit has powered up.adTRACERYellow a change in the YELLOW alarm state has occurred and the YELLOW alarm is now active.adTRACERAIS a change in the Alarm Indication Signal (AIS) has occurred and the AIS alarm is active.adTRACERRedAlarm a change in the RED alarm state has occurred and the RED alarm is now active.adTRACERLOS a change in the Loss of Signal (LOS) state has occurred and the LOS alarm is active.adTRACERBPV a change in the BiPolar Violation (BPV) state has occurred and the BPV alarm is active.adTRACERRA a change in the Frame RA (Remote Alarm) state has occurred and the RA alarm is active.adTRACEROOF a change in the Out Of Frame (OOF) state has occurred and the OOF alarm is active.adTRACERCV a change in the Code Violation (CV) state has occurred and the CV alarm is active.adTRACERCRC a change in the Cyclic Redundancy Check (CRC) state has occurred and the CRC alarm is active.adTRACERmfLOF a change in the Loss of Multiframe (LOMF) state has occurred and the LOMF alarm is active.adTRACERmfLOS a change in the Multiframe Loss of Signal (LOS) state has occurred and the Multiframe LOS alarm is active.adTRACERmfAIS a change in the Multiframe Alarm Indication Signal (AIS) state has occurred and the Multiframe AIS alarm is active.adTRACERmfRA a change in the Multiframe Remote Alarm (RA) has occurred and the Multiframe RA alarm is active.adTRACERlineLoopback a change in the line loopback state has occurred and the line loopback is active.adTRACERlinkLoopback a change in the link loopback state has occurred and the link loopback is active.adTRACERYellowOff a change in the YELLOW alarm state has occurred and the YELLOW alarm is now inactive.adTRACERAISoff a change in the Alarm Indication Signal (AIS) has occurred and the AIS alarm is inactive.adTRACERRedAlarmOff a change in the RED alarm state has occurred and the RED alarm is now inactive.adTRACERLOSoff a change in the Loss of Signal (LOS) state has occurred and the LOS alarm is inactive.
Section 7  MIBs TRACER 6420 System Manual 94 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ATRACER.mib adTRACERBPVoff a change in the BiPolar Violation (BPV) state has occurred and the BPV alarm is inactive.adTRACERRAoff a change in the Frame RA (Remote Alarm) state has occurred and the RA alarm is inactive.adTRACEROOFoff a change in the Out Of Frame (OOF) state has occurred and the OOF alarm is inactive.adTRACERCVoff a change in the Code Violation (CV) state has occurred and the CV alarm is inactive.adTRACERCRCoff a change in the Cyclic Redundancy Check (CRC) state has occurred and the CRC alarm is inactive.adTRACERmfLOFoff a change in the Loss of Multiframe (LOMF) state has occurred and the LOMF alarm is inactive.adTRACERmfLOSoff a change in the Multiframe Loss of Signal (LOS) state has occurred and the Multiframe LOS alarm is inactive.adTRACERmfAISoff a change in the Multiframe Alarm Indication Signal (AIS) state has occurred and the Multiframe AIS alarm is inactive.adTRACERmfRAoff a change in the Multiframe Remote Alarm (RA) has occurred and the Multiframe RA alarm is inactive.adTRACERlineLoopbackOff a change in the line loopback state has occurred and the line loopback is inactive.adTRACERlinkLoopbackOff a change in the link loopback state has occurred and the link loopback is inactive.adTRACERLinkDown the RF link is down.adTRACERLinkUp the RF link is up.adTRACERRFCLinkDown the RFC link is down between the Indoor Unit (IDU) and Outdoor Unit (ODU).adTRACERRFCLinkUp the RFC link is up between the IDU and ODU.adTRACERRxLow the receive level is within 10 dB of sensitivity and the RF Low alarm is active.adTRACERRxLevel a change in receive level has occurred and the receive level is within normal range.adTRACERcurrThrsESon the threshold for current Errored Seconds (ES) has been exceeded.adTRACERcurrThrsESoff the threshold for current ES has not been exceeded.adTRACERcurrThrsSESon the threshold for current Severely Errored Seconds (SES) has been exceeded.adTRACERcurrThrsSESoff the threshold for current SES has not been exceeded.Table 3.  Traps Supported by the TRACER 6420 (Continued)MIB Trap This trap indicates that....
TRACER 6420 System Manual Section 7  MIBs612806420L1-1A Copyright © 2005 ADTRAN, Inc. 954. MIB VARIABLES SUPPORTED BY THE TRACER 6420Table 4.  MIB Variables for ad.mi2  adadProductsadProductInfoadProdName DisplayString ROadProdPartNumber DisplayString ROadProdCLEIcode DisplayString ROadProdSerialNumber DisplayString ROadProdRevision DisplayString ROadProdSwVersion DisplayString ROadProdPhysAddress PhysAddress ROadProdProductIDadProdTransType DisplayString ROadMgmtadAdminadPerformadSharedadIdentityadIdentitySharedadAgentCapModuleadAgentCapProductadAgentCapSharedadConformanceadCompliances
Section 7  MIBs TRACER 6420 System Manual 96 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ATable 5.  MIB Variables for ads1.mib  adDS1AlarmTableadDS1AlarmEntryadDS1AlarmIndex Integer ROadDS1AlarmEnable Integer RWadDS1LineEvent  Integer ROadDS1LineArm Integer RWadDS1AlertTableadDS1AlertEntryadDS1AlertIndex Integer ROadDS1AlertEnable Integer RWadDS1CurrentAlert Integer ROadDS1TotalAlert Integer ROadDS1FarCurrentAlert Integer ROadDS1FarTotalAlert Integer ROadDS1CurrentArm Integer RWadDS1TotalArm Integer RWadDS1FarCurrentArm Integer RWadDS1FarTotalArm Integer RWadDS1CurrentThresholdadDS1CurrentThrsES Integer RWadDS1CurrentThrsSES Integer RWadDS1CurrentThrsSEFS Integer RWadDS1CurrentThrsUAS Integer RWadDS1CurrentThrsCSS Integer RWadDS1CurrentThrsPCVsf Integer RWadDS1CurrentThrsPCVesf Integer RWadDS1CurrentThrsLES Integer RWadDS1CurrentThrsLCV Integer RWadDS1TotalThresholdadDS1TotalThrsES Integer RWadDS1TotalThrsSES Integer RWadDS1TotalThrsSEFS Integer RWadDS1TotalThrsUAS Integer RWadDS1TotalThrsCSS Integer RWadDS1TotalThrsPCVsf Integer RWadDS1TotalThrsPCVesf Integer RWadDS1TotalThrsLES Integer RWadDS1TotalThrsLCV Integer RW
TRACER 6420 System Manual Section 7  MIBs612806420L1-1A Copyright © 2005 ADTRAN, Inc. 97Table 6.  MIB Variables for TRACER.mib  adTRACER6420mgadTRACER6420statusadTRACERRFlinkState DisplayString ROadTRACERRFClinkState DisplayString ROadTRACERrfLow DisplayString ROadTRACERRXquality DisplayString ROadTRACERRXLevel DisplayString ROadTRACERFrequencyPlan DisplayString ROadTRACERLEDStatus DisplayString ROadTRACERSlot1 DisplayString ROadTRACERSlot2 DisplayString ROadTRACER6420cfgadTRACERBaudRate Integer RWadTRACERBandPlan Integer RWadTRACERactiveChannels Integer RWadTRACERchannelSelectadTRACERdsx1ChannelSelectTableadTRACERdsx1ChannelSelectEntryAdTRACERdsx1ChannelSelectEntryadTRACERdsx1ChannelSelectIdx Integer ROadTRACERdsx1ChannelSelection Integer RWadTRACERswitchChannelSelectTableadTRACERswitchChannelSelectEntryAdTRACERswitchChannelSelectEntryadTRACERswitchChannelSelectIdx Integer ROadTRACERswitchChannelSelection Integer RWadTRACERTxPower DisplayString RWadTRACERalarmTableAdTRACERAlarmEntryadTRACERalarmEntryadTRACERalarmNumber Integer ROadTRACERAlarmReporting Integer RWadTRACERClearHistory Integer RWadTRACERrfTrapEnable Integer RWadTRACERswitchModuleCfgadTRACERswitchPortCfgTableadTRACERswitchPortCfgEntryAdTRACERswitchPortCfgEntryadTRACERswitchPortIdx Integer ROadTRACERswitchPortEnable Integer ROadTRACERswitchPortSpeedDuplex Integer RW
Section 7  MIBs TRACER 6420 System Manual 98 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AadTRACERswitchModuleStatusadTRACERswitchPortStatusTableadTRACERswitchPortStatusEntryAdTRACERswitchPortStatusEntryadTRACERswitchPortStatusIdx Integer ROadTRACERswitchPortTxPackets Integer ROadTRACERswitchPortTxPacketsDrop Integer ROadTRACERswitchPortRxPackets Integer ROadTRACERswitchPortRxPacketsDrop Integer ROadTRACERswitchPortRxPacketError Integer ROadTRACERswitchWanStatusTableadTRACERswitchWanStatusEntryAdTRACERswitchWanStatusEntryadTRACERswitchWanStatusIdx Integer ROadTRACERswitchWanTxPackets Integer ROadTRACERswitchWanTxPacketsDrop Integer ROadTRACERswitchWanRxPackets Integer ROadTRACERswitchWanRxPacketsDrop Integer ROadTRACERswitchWanRxPacketError Integer ROadTRACER6420ipadTRACERIpAddress IpAddress ROadTRACERSubnetMask IpAddress ROadTRACERGatewayIp IpAddress ROadTRACER6420trapIPadTRACERTrapIpHost1 IpAddress RWadTRACERTrapIpHost2 IpAddress RWadTRACERTrapIpHost3 IpAddress RWadTRACERTrapIpHost4 IpAddress RWadTRACERTrapIpHost5 IpAddress RWadTRACER6420currentadTRACERCurrentRFs Integer ROadTRACERCurrent24hRFs Integer ROadTRACERCurrentRFCs Integer ROadTRACERCurrent24hRFCs Integer ROadTRACERCurrentRxLs Integer ROadTRACERCurrentMaxRxLs Integer ROadTRACERCurrent24hMaxRxLs Integer ROadTRACERCurrentMinRxLs Integer ROadTRACERCurrent24hMinRxLs Integer ROadTRACERCurrentRxQs Integer ROadTRACERCurrentMaxRxQs Integer ROTable 6.  MIB Variables for TRACER.mib  (Continued)
TRACER 6420 System Manual Section 7  MIBs612806420L1-1A Copyright © 2005 ADTRAN, Inc. 99adTRACERCurrent24hMaxRxQs Integer ROadTRACERCurrentMinRxQs Integer ROadTRACERCurrent24hMinRxQs Integer ROadTRACERIntervalTableAdTRACERInteralEntryadTRACERIntervalEntryadTRACERIntervalNumber Integer ROadTRACERIntevalRFs Integer ROadTRACERIntervalRFCs Integer ROadTRACERIntervalMaxRxLs Integer ROadTRACERIntervalMinRxLs Integer ROadTRACERIntervalMaxRxQs Integer ROadTRACERIntervalMinRxQs Integer ROadTRACERIntervalValidData TruthValue ROadTRACERtotalTableAdTRACERtotalEntryadTRACERtotalEntryadTRACERtotalNumber Integer ROadTRACERtotalRFs Integer ROadTRACERtotalRFCs Integer ROadTRACERtotalMaxRxLs Integer ROadTRACERtotalMinRxLs Integer ROadTRACERtotalMaxRxQs Integer ROadTRACERtotalMinRxQs Integer ROadTRACERtotalValidData TruthValue ROadTRACER6420remoteStatusadTRACERremoteRFlinkState DisplayString ROadTRACERremoteRFClinkState DisplayString ROadTRACERremoteRFLow DisplayString ROadTRACERremoteRXquality DisplayString ROadTRACERremoteRXLevel DisplayString ROadTRACERremoteFrequencyPlan DisplayString ROadTRACERremoteLEDStatus DisplayString ROadTRACERremoteSlot1 DisplayString ROadTRACERremoteSlot2 DisplayString ROadTRACER6420remoteCfgadTRACERremoteBaudRate Integer RWadTRACERremoteBandPlan Integer RWadTRACERremoteActiveChannels Integer RWadTRACERremoteChannelSelectTable 6.  MIB Variables for TRACER.mib  (Continued)
Section 7  MIBs TRACER 6420 System Manual 100 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AadTRACERremoteDSX1ChannelSelectTableAdTRACERremoteDSX1ChannelSelectEntryadTRACERremoteDSX1ChannelSelectEntryadTRACERremoteDSX1ChannelSelectIdx Integer ROadTRACERremoteDSX1ChannelSelection Integer RWadTRACERremoteSwitchChannelSelectTableAdTRACERremoteSwitchChannelSelectEntryadTRACERremoteSwitchChannelSelectEntryadTRACERremoteSwitchChannelSelectIdx Integer ROadTRACERremoteSwitchChannelSelection Integer RWadTRACERremoteTxPower DisplayString RWadTRACERremoteAlarmTableAdTRACERremoteAlarmEntryadTRACERremoteAlarmEntryadTRACERremoteAlarmNumber Integer ROadTRACERremoteAlarmReporting Integer RWadTRACERremoteSetPassword DisplayString ROadTRACERremoteClearHistory Integer RWadTRACERremoterfTrapEnable Integer RWadTRACERremoteswitchModuleCfgadTRACERremoteswitchPortCfgTableadTRACERremoteswitchPortCfgEntryAdTRACERremoteswitchPortCfgEntryadTRACERremoteswitchPortIdx Integer ROadTRACERremoteswitchPortEnable Integer ROadTRACERremoteswitchPortSpeedDuplex Integer RWadTRACERremoteswitchModuleStatusadTRACERremoteswitchPortStatusTableadTRACERremoteswitchPortStatusEntryAdTRACERremoteswitchPortStatusEntryadTRACERremoteswitchPortStatusIdx Integer ROadTRACERremoteswitchPortTxPackets Integer ROadTRACERremoteswitchPortTxPacketsDrop Integer ROadTRACERremoteswitchPortRxPackets Integer ROadTRACERremoteswitchPortRxPacketsDrop Integer ROadTRACERremoteswitchPortRxPacketError Integer ROadTRACERremoteswitchWanStatusTableadTRACERremoteswitchWanStatusEntryAdTRACERremoteswitchWanStatusEntryadTRACERremoteswitchWanStatusIdx Integer ROadTRACERremoteswitchWanTxPackets Integer ROTable 6.  MIB Variables for TRACER.mib  (Continued)
TRACER 6420 System Manual Section 7  MIBs612806420L1-1A Copyright © 2005 ADTRAN, Inc. 101adTRACERremoteswitchWanTxPacketsDrop Integer ROadTRACERremoteswitchWanRxPackets Integer ROadTRACERremoteswitchWanRxPacketsDrop Integer ROadTRACERremoteswitchWanRxPacketError Integer ROadTRACER6420remoteTrapIPadTRACERremoteTrapIpHost1 IpAddress RWadTRACERremoteTrapIpHost2 IpAddress RWadTRACERremoteTrapIpHost3 IpAddress RWadTRACERremoteTrapIpHost4 IpAddress RWadTRACERremoteTrapIpHost5 IpAddress RWadTRACERremotecurrentadTRACERremoteCurrentRFs Integer ROadTRACERremoteCurrent24hRFs Integer ROadTRACERremoteCurrentRFCs Integer ROadTRACERremoteCurrent24hRFCs Integer ROadTRACERremoteCurrentRxLs Integer ROadTRACERremoteCurrentMaxRxLs Integer ROadTRACERremoteCurrent24hMaxRxLs Integer ROadTRACERremoteCurrentMinRxLs Integer ROadTRACERremoteCurrent24hMinRxLs Integer ROadTRACERremoteCurrentRxQs Integer ROadTRACERremoteCurrentMaxRxQs Integer ROadTRACERremoteCurrent24hMaxRxQs Integer ROadTRACERremoteCurrentMinRxQs Integer ROadTRACERremoteCurrent24hMinRxQs Integer ROadTRACERremoteIntervalTableAdTRACERremoteInteralEntryadTRACERremoteIntervalEntryadTRACERremoteIntervalNumber Integer ROadTRACERremoteIntevalRFs Integer ROadTRACERremoteIntervalRFCs Integer ROadTRACERremoteIntervalMaxRxLs Integer ROadTRACERremoteIntervalMinRxLs Integer ROadTRACERremoteIntervalMaxRxQs Integer ROadTRACERremoteIntervalMinRxQs Integer ROadTRACERremoteIntervalValidData TruthValue ROadTRACERremoteTotalTableAdTRACERremoteTotalEntryadTRACERremoteTotalEntryadTRACERremoteTotalNumber Integer ROTable 6.  MIB Variables for TRACER.mib  (Continued)
Section 7  MIBs TRACER 6420 System Manual 102 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AadTRACERremoteTotalRFs Integer ROadTRACERremoteTotalRFCs Integer ROadTRACERremoteTotalMaxRxLs Integer ROadTRACERremoteTotalMinRxLs Integer ROadTRACERremoteTotalMaxRxQs Integer ROadTRACERremoteTotalMinRxQs Integer ROadTRACERremoteTotalValidData TruthValue ROTable 6.  MIB Variables for TRACER.mib  (Continued)
612806420L1-1A Copyright © 2005 ADTRAN, Inc.  103TROUBLESHOOTING GUIDEProvides helpful information for troubleshooting common configuration problems for the TRACER 6420.CONTENTSOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104PWR LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104TST LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104RF DWN LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104RF LOW LED  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105T1 Interface Alarm LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106RF Errors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Step-by-Step Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Installing/Troubleshooting the TRACER Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Installing/Configuring T1 Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Installing/Configuring Ethernet Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Section 8  Troubleshooting Guide TRACER 6420 System Manual 104 Copyright © 2005 ADTRAN, Inc. 612806420L1-1A1. OVERVIEWThis troubleshooting guide provides recommended actions for various conditions of the TRACER 6420 system. The status LEDs (located on the front panel of the unit) provide information to help determine the necessary troubleshooting action. This guide contains recommended actions for resolving possible problems indicated by the status LEDs.2. LED INDICATORSPWR LEDIf the PWR LED is not ON and solid green, the TRACER 6420 is not receiving adequate DC power. Recommended Actions:1. Verify that the power source is delivering between 21 and 60 VDC.2. Check the polarity of the power connection (referenced to ground) of both the TRACER 6420 unit and the power source.3. Check the internal fuse. The fuse is accessed from the rear panel of the unit. If this fuse is open, replace with a 2 A, 250 V (2-inch) slow-blo fuse.TST LEDThe TST LED will flash once (amber) during power-up to indicate a self-test is in progress. If the TST LED is flashing or remains ON after 10 seconds, the TRACER 6420 unit has failed the self-test. This is an internal failure, and technical support should be contacted.RF DWN LEDIf the RF DWN LED is ON (solid red), there is a problem with the RF receive path from the remote TRACER 6420.Recommended Actions:1. Verify that one end of the link is configured as Plan A and the other end as Plan B.2. Measure the RSSI voltage and consult the RSSI calibration sheet included with the unit. If the voltage level corresponds to a received signal power level that agrees with the calculated receive signal level, proceed with Step 7.3. Check the RF coaxial cable connection.4. Verify that the antenna polarization is the same at both ends of the RF signal transmit and receive path.5. Verify the RF signal path is clear.6. Check the integrity of the lightning arrestors.7. Check for possible interference at both ends of the link. If necessary, change polarization and/or band plans at both ends.
TRACER 6420 System Manual Section 8  Troubleshooting Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 105RF LOW LEDIf the RF LOW LED is ON (solid red), the received signal is approaching 0 V of RSSI. This condition is typically indicative of a path or installation problem.Recommended Actions:1. Verify the far-end transmitter power setting is the value that the link planning budget allows.2. Check all coaxial cable connectors for solid connections. Check for water and corrosion around any of the connectors. If water is apparent in the coaxial connectors, replace the coaxial cable and the connectors, making sure to properly weatherproof the replacements.3. Verify the RF signal path by verifying the antenna alignment.4. Check the integrity of lightning arrestors.T1 Interface Alarm LEDsIf the ALARM LED is ON (solid red), it is an indication that the TRACER 6420 is detecting an active T1 alarm. To identify the T1 interface in alarm and the specific alarm present, display the T1(X) STATUS screens and check the T1(X) INTERFACE ALARMS field.Recommended Actions:1. Display the T1(X) STATUS screen and check the T1(X) INTERFACE ALARM field to identify the active alarm. 2. Follow the steps below for the appropriate alarm.LOS Alarm (Red Alarm)LOS ALARM is an indication that the TRACER 6420 may be unable to detect a viable T1 received signal from the connected T1 equipment. This error may be due to a degraded signal or no signal, or may be caused by improper framing.Recommended Actions:1. Verify that the T1 cable is connected to the T1 interface on the TRACER 6420.2. Verify the connections at the opposite end of the T1 cable.3. Verify that the framing mode (D4 or ESF) is the same for both the TRACER 6420 and the T1 equipment.Yellow AlarmA Yellow Alarm is generated by the attached equipment. When the attached equipment’s T1 interface is in Red Alarm, the TRACER 6420 generates a Yellow Alarm.Recommended Actions:1. Follow the troubleshooting steps for Red Alarm, but do so at the attached equipment.Blue Alarm A remote alarm (alarm indication signal or AIS) is generated by the attached equipment. The root cause must be determined at the attached equipment. A typical cause of a blue alarm is a lack of input to a CSU.Recommended Actions:1. Verify the input to any attached data equipment.
Section 8  Troubleshooting Guide TRACER 6420 System Manual 106 Copyright © 2005 ADTRAN, Inc. 612806420L1-1ABPVBipolar violations (BPVs) indicate an improper configuration or faulty wiring.Recommended Actions:1. Verify the TRACER 6420 unit and the attached equipment are configured for the same line coding (B8ZS or AMI).2. Verify the cable connections for the T1 interface are solid.LAN LEDsIf the LAN LED is OFF, the TRACER 6420 is not able to detect an active Ethernet link on the particular 10/100BaseT/TX interface. Recommended Actions:1. Check all Ethernet cable connections to verify they are properly plugged in (making sure the tab on the connector snaps into place). 2. Connect the 10/100BaseT/TX interface to a “known good” Ethernet port to verify the TRACER port is functioning properly.3. Try another Ethernet cable.3. RF ERRORSRF errors can range from a nonviable microwave path to loose RF connectors.Nonviable path conditions could be caused by physical obstructions such as buildings, mountainous terrain, trees, etc., as well as other physical limitations such as excessive path distances and in-band RF interference. These types of errors are remedied by performing a detailed line-of-site microwave path study to determine whether a microwave link is feasible for the terrain and environment under consideration.If after performing a microwave path study the system is still not operational, ensure that the antennas are properly aligned. Note that alignment must be achieved in both elevation and azimuth for optimal link performance. The TRACER 6420 can be used to aid in antenna alignment by looking at the RX POWER “fuel gauge” on the System Status or System Option menu pages or by measuring the DC voltage (relative to ground) at the RSSI front panel test jack. Optimal antenna alignment is achieved by peaking the front panel RSSI voltage or the RX POWER “fuel gauge” on the TRACER 6420 terminal display. Consult the ADTRAN TRACER Data Sheet included with the unit to verify that the actual receive signal level agrees with the calculated receive signal.An RSSI test point, located on the front panel, provides a DC voltage level (relative to the GND test point) that corresponds to the amount of signal being received from the far end's transmitter. The voltage at this test point can vary from approximately 0 to 5 VDC. An RSSI calibration sheet is shipped with the system to provide the installer a cross-reference between actual received signal level (in dBm) and RSSI voltage. This sheet is useful for verifying link budget calculations and ensuring proper equipment installation.4. STEP-BY-STEP TROUBLESHOOTINGThe logical troubleshooting flow presented in this section can be used to set up your TRACER 6420 system, and also to diagnose a previously installed system. Please contact Technical Support at any stage during installation and/or troubleshooting if you require assistance.
TRACER 6420 System Manual Section 8  Troubleshooting Guide612806420L1-1A Copyright © 2005 ADTRAN, Inc. 1075. INSTALLING/TROUBLESHOOTING THE TRACER HARDWARE1. Perform a detailed path profile and link budget for each TRACER 6420 microwave link. A thorough path study can be used to estimate signal power budgets, estimate fade margins at each receiver, identify potential line-of-site obstacles, properly size antenna dishes, and determine minimum antenna dish heights above the earth.2. Set up all of the TRACER 6420 hardware on a workbench. The actual cables used in the permanent installation should be used in the workbench setup. A rigorous workbench “simulation” of the link will help alleviate and avoid time-consuming errors.3. Examine the PLAN A and PLAN B LEDs on the front panel of each unit. These LEDs indicate the frequency plan for each TRACER 6420 unit. Each TRACER link must have a Plan A radio on one side and a Plan B radio on the other.4. Attach the RF coaxial cables to be used in the permanent installation to the N-type connectors on the back of the TRACER 6420 unit. Attach the other end of the coaxial cable(s) to an RF power meter or spectrum analyzer, if either is available. The power measured by the meter/analyzer will be the RF power available at the input of the antenna. The TRACER 6420 unit is programmed at the factory to output approximately 100 mW (20 dBm) of RF power. The actual power level measured by the meter/analyzer will be less than 100 mW due to RF losses through the coaxial cable, and is a function of the cable type and length being used. In any event, the power level at the output of the coaxial cable should be a significant fraction of 100 mW. A power meter/analyzer reading that is not on the order of at least tens-of-milliwatts could be an indication of unsuitable RF cable or faulty or unreasonably long coaxial cable, or a combination of these factors.5. Resolve all RF coaxial cabling errors before proceeding.6. Attach the RF coaxial cables to a high-quality attenuator, if possible. If you do not have an attenuator, attach the coaxial cables to the antennas to be used in the permanent installation. If the installation antennas are not available, small, inexpensive dipole or patch antennas can be used for verification purposes. If an adjustable attenuator is being used, dial in the amount of attenuation that corresponds to the path loss value expected for the microwave link in which the TRACER hardware will be installed. The path loss value can be calculated from a knowledge of the path length, or provided by a path study. Remember to subtract both antenna gain values from the attenuator level if these values have not already been accounted for.7. After setting up the RF pieces, examine the RF DOWN LED on the front panel of each TRACER 6420 unit. If the RF DOWN LED is illuminated (red), the corresponding TRACER 6420 is not receiving a suitable RF signal from the other TRACER 6420 unit. In this case, the receiving TRACER 6420 is either receiving a very weak signal or no signal at all. If the RF DOWN LED is not illuminated, then the TRACER 6420 units are receiving a suitable RF signal. Suitable RF power levels for low error rate communication will range from -30 dBm to -88 dBm measured at the N-type connector input on the TRACER 6420 unit.8. Resolve any signal level issues before proceeding.9. Examine the RF LOW LED on the front panel of each TRACER 6420. If this LED is illuminated, then the TRACER 6420 is receiving a relatively weak signal; however, if the RF DOWN LED is not illuminated, then the received signal is being suitably processed by the TRACER 6420 system. If you are receiving a weak signal (RF LOW is ON), please verify that the weak signal is not being caused by a faulty cable, an insufficiently tightened cable, or some other installation-related problem. Also, make sure an unreasonably large attenuation value has not been selected if you are using an attenuator on a workbench setup.
Section 8  Troubleshooting Guide TRACER 6420 System Manual 108 Copyright © 2005 ADTRAN, Inc. 612806420L1-1AUse the tables in Section 2, Microwave Path Engineering Basics, of this manual to select the proper free-space attenuation value (in dB) based on the estimated length of the microwave path. Remember to subtract both antenna gains (local and remote) from the attenuator setting.10. Test the installed modules by performing the following: 11. Command a link loopback on the remote TRACER 6420 unit and run a test pattern from the connected T1 equipment. This will verify the data path across the RF link. Installing/Configuring T1 Hardware1. If possible, attach any or all of the intended T1 hardware to the TRACER 6420 units using the same workbench setup. This step offers the perfect opportunity to configure your T1 hardware for proper functioning with the TRACER 6420 hardware.2. To significantly reduce the probability of an unsuccessful field installation, resolve any remaining T1 equipment-to-TRACER 6420 configuration issues before field installation. See T1 Interface Alarm LEDs on page 105 for more information on resolving T1 interface alarm conditions.Installing/Configuring Ethernet Hardware1. If possible, attach any or all of the intended Ethernet hardware to the TRACER 6420 units using the same workbench setup. This step offers the perfect opportunity to configure your Ethernet hardware for proper functioning with the TRACER hardware.2. To significantly reduce the probability of an unsuccessful field installation, resolve any remaining Ethernet equipment-to-TRACER 6420 configuration issues before field installation.4xT1 Module Initiate a line loopback on the local TRACER 6420 unit and run a test pattern from the connected T1 equipment. This will verify the connection between the T1 equipment and the local TRACER 6420 unit.Quad Ethernet Switch Module Connect a computer (or Ethernet test equipment) to the TRACER 6420 Ethernet interfaces. Perform a “ping” from one test station across the wireless link to another test station connected to the remote TRACER 6420. This will verify the data path between the test equipment and the TRACER 6420 unit.External pattern generators are required to test data path integrity. An T1 BERT tester is suggested.