Advan AMM261WTD LCD Color Medical Monitor User Manual

Advan Int'l Corp. LCD Color Medical Monitor

User manual

AUTO - SCANNING WITH DIGITAL CONTROLLCD COLOR MEDICAL MONITORAMM261WTDOperation ManualFor future reference, record the serial number of your display monitor in the space below :Serial NumberThe serial number is located on the back of the monitor
back of the monitorADVAN INT’L CORP.2013             All other trademarks are the property of their reference owners.This document is subject to change without notice.Advan provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement.Revision ControlWARNINGThe title «WARNING» is used to inform the users of pos-sible causes that could inict the injury, death, or property damage to the patients. CAUTIONThe title «CAUTION» is used to inform the users of pos-sible causes that could inict the patients although it might not severe enough to cause deaths. NOTEThe title «NOTE» is used to inform the users of items that are of importance in terms of installation, operation, or maintenance of the Equipment although the failure does not inict the bodily harm to the patients. Document numberDraftAMM261WTD   1
TABLE OF CONTENTSProduct Description and Intended Use ......................................................Warnings and Cautions .............................................................................Symbol Explanations .................................................................................EU Declaration of Conformity for Medical Applications .............................Safety Precaution ......................................................................................Cleaning Your Monitor ...............................................................................Recommendation to Use more than One Unit...........................................On Burn-in .................................................................................................Power Management Function....................................................................Preset Modes..............................................................................................Video Signals .............................................................................................PIP / POP / PBP function...........................................................................DDC ...........................................................................................................Installation .................................................................................................Connecting the Power Cord ......................................................................User Function / Messages.........................................................................OSD Section ..............................................................................................Troubleshooting .........................................................................................Specication of (AMM261WTD) ................................................................Classication .............................................................................................Electromagnetic Compatibility ...................................................................Dimension Drawing (mm) of AC Adapter ...................................................Dimension Drawing (mm) of AMM261WTD...............................................Connectors ................................................................................................Description of Warranty .............................................................................Accessory Item List  ..................................................................................  3  4  7  8  9  9991011121314141516172526272830313233372    User’s Guide
Product Description and Intended UsePlease check the following items are present when you unpack the box, and save the packing materials in case you will need to ship or transport the monitor in future.• AMM261WTD LCD Monitor(the equipment that displays information, graphic data, image and video on its LCD screen) and two video cables    (1) HD15 VGA cable (1) DVI-I cable • AC Power cord*• AC-Adapter• Composite Video BNC Jack Cable, and Super Video Cable.• User Manual, Quick Reference Guide and 4pcs VESA screws *Might vary pending on region standardCAUTIONModel No : BPM150S24F10 AMM261WTD   3
Warnings and CautionsPlease read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed: Warning  The personal safety of the patient or physician may be                  involved. Disregarding this information could result in                  injury to the patient or physician.Caution  Special service procedures or precautions must be                   followed to avoid damaging the instrument.Note  Special information to make maintenance easier or important information more clear.                  An exclamation mark within a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the product.                  A lightning bolt within a triangle is intended to warn of the                   presence of hazardous voltage. Refer all service to authorized personnel.Warning  TO AVOID POTENTIAL SERIOUS INJURY TO THE USER AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE, THE USER MUST :Warranty is void if any of these warnings are disregarded. ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and performance of the equipment only if:• Re-adjustments, modications, and/or repairs are carried out exclusively    by ADVAN Int’l Corp.• The electrical installation of the relevant operating room complies with the    applicable IEC and CE requirements.Warning      Federal law (United States of America) restricts this                     device to use by, or on order of a physician.The ADVAN Int’l Corp AMM261WTD monitor has been tested under UL 60601-1 standard and UL listed for Medical application. ADVAN Int’l Corp reserves the right to make improvements in the product(s) described herein. Product(s), therefore, may not agree in detail to the published design or specications. All specications are subject to change without notice. Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales representative or agent for information on changes and new products.4    User’s Guide
Warnings1.  Read the operating manual thoroughly and be familiar with its contents prior to using      this equipment.2.  Carefully unpack the unit and check if any damage occurred during shipment.3.  Should any solid object or liquid fall into the panel, unplug the unit and have it checked      by qualied personnel before operating it any further.4.  Uplug the unit if it is not to be used for an extended period of time. To disconnect the      cord, pull it out by the plug. Never pull the cord itself.5.  Be a qualied physician, having complete knowledge of the use of this equipment.6.  Test this equipment prior to a medical procedure. This monitor was fully tested at the      factory before shipment.7.  Avoid removing covers on control unit to avoid electric shock.8.  Attempt no internal repairs or adjustments not specically detailed in this operating      manual.9.  Pay close attention to the care, cleaning instructions in this manual. A deviation may      cause damage (refer to the Cleaning section).10. DO NOT STERILIZE MONITOR.11. Read the entire instruction manual before assembling or connecting the camera.12. Do not place the monitor or any other heavy object on the power cord. Damage to the       cable can cause re or electirc shock.13. Monitor with power supply is suitable for use in patient environment.14. DO NOT stack more than 3 boxes highThis equipment has been tested and found to comply with the limits for medical devices in IEC 60601-1-2:2003. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devic-es in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  - Reorient or relocate the receiving device.  - Increase the separation between the equipment.  - Connect the equipment into an outlet on a circuit different from that to which the other   device(s) are connected.  - Consult the manufacturer or eld service technician for help.NOTICES TO USERThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any inter-ference received, including interference that may cause undesired operation.FCC WARNINGThis equipement generates or uses radio frequency energy.  Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The user could lose the authority to operate this equipment if an unauthorized change or modication is made. AMM261WTD   5
Cautions1.  The AC Adapter must be plugged into a Grounded power outlet.2.  Use only the proprietary  AMM261WTD power supply for the      AMM261WTD monitor. Make a proper connection by ensuring that the      shrink tubing completely secures the connection between the DC power cord and the      extension cord.3.  Turn power off when unit is not in use.4.  Never operate the unit right after having transported from a cold location directly to a      warm location.5.  Do not expose the monitor to moisture or directly apply liquid cleaners directly to the      screen. Spray the cleaning solution into a soft cloth and clean gently.6.  Handle the monitor with care. Do not strike or scratch the screen.7.  Do not block the monitor cooling vents. The monitor is cooled by natural convection      and has no fan. 8.  Do not force the monitor past 28 degrees of vertical when adjusting the screen      position. (For monitors equipped with stands only.)9.  Remove the power module and connection when transporting the unit.10. Save the original carton and associated packing material. They will be useful should        you have to transport or ship the unit.11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,       draperies) that may block the ventilation slots.13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.14. The unit is designed for operation in a horizontal position. Never operate the unit in        a vertical position.15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)16. Do not expose the monitor to moisture or excessive dust.17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or       IEC 60601-1-1 harmonized national standard or the combination should be evaluated.       Do not touch the patient with signal input or output connectors.18. Use only a hospital grade power supply cord.19. This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable generate uses and can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation, which can be detemined by turing the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving device.  •  Increase the separation distance between the equipment.  •  Connect the equipment to an outlet on a circuit different from that to which the       other device(s) are connected.  •  Consult the manufacturer or eld service technican for help.20. Grounding reliability can only be achieved when the equipment is connected to an       equipment receptacle labeled “Hospital Only” or “Hospital Grade.”Note  To connect to an international power supply, use a an attachment plug                appropriate for the power outlet.Note  Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to                ensure EMC. The AMM261WTD must be installed and operated                according to the EMC information provided in this manual.6    User’s Guide
Symbol DenitionsAMM261WTD   7Dangerous: High VoltageDirect CurrentSerial NumberThis way upFragile, handle with careStacking limit by numberKeep dryRecyclableSee accompanying documentIndicates proof of confor-mity to applicable European EconomicCommunity Council directives and to harmonized standards published in the of-cial journal of the European Communities.Authorized Representative in EuropeDate of Manufacture51LJMedical EquipmentE215822Indicates protective earth ground.For indoor use only.Tested to comply with FCC Class B standards.DC power control switchTested to comply with Japan VCCI certicationTested to comply with China CCC certicationChina RoHS symbol. Number indicates EFUP(Environmental Friendly Use Period) from the date of manufacturing.Medical Equipment is in ac-cordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1 in regards to electric shock, re hazards, and mechanical hazardsTested to comply with IP (ingression protection) RatingWEEE symbol for the recyclable product. Please do not throw the product with this symbol in the bin.Manufacturer
EU Declaration of Conformity for Medical ApplicationsA Declaration of Conformity has been led for this product. A sample of this document may be found in the addendum which accompanied this manual.  For a copy of the Declaration of Conformity document, please contact ADVAN Int’l Corp. and request for AMM261WTD DOC.Prepare for UnpackBefore you unpack your monitor, prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area which is relatively free of glare from sunlight or other sources of bright light. The monitor is cooled by natural convection (it has no fan). For optimum performance, do not block the cooling vents.While unpacking the monitor, inspect it and other package contents for shipping damage that could cause a re or shock hazard. Imme-diately report any shipping damage to the carrier or transportation company and contact customer service for monitor in the future or in case of return.After you unpack the monitor, make sure the following items are in-cluded  •  Monitor with video cable  •  AC adapter with cable           CAUTION: AC Adapter must be plugged into Grounded a power outlet          CAUTION : AC adapter          Model No: BPM150S24F10       •  This operations manual          Note:  Your system provider may offer alternative cords or cables depending on the installation requirement and local geography issues.8    User’s Guide
SAFETY PRECAUTION·  Avoid placing the monitor, or any other heavy object, on the power cord        to prevent re or electrical shock from damage to the power cord.·  Do not expose the monitor to rain, excessive moisture, or dust to avoid        re or shock hazard.·  Do not cover the slots or openings of the monitor for proper heat        dissipation. Always put the monitor in a place where there is adequate       ventilation.·  Avoid placing the monitor against a bright background or where sunlight       or other light sources may reect on the area of the monitor. Place the       monitor just below eye level.·  Handle with care when transporting the monitor.·  Refrain from giving the shock or scratch to the screen, as screen is        fragile.CLEANING YOUR MONITORNo specic liquid or chemical necessary when cleaning this LCD monitorHowever, we suggest to clean the monitor with non-abrasive cloths and cleaning solutions used in hospitals to clean similar equipment. We recommend using 70% Isopropyl alcohol for the screen surface and warm water and a mild detergent for all other surfaces. Other acceptable cleaning agents are listed below:  •  70% isopropyl alcohol  •  Cidex (2.4% glutaraldehyde solution)  •  0.5% Chlorhexidine in 70% isopropyl alcoholTo clean the screen, do not spray liquid cleaners directly on to the unit. Stand away Form the monitor and spray cleaning solution onto a cloth. Without applying exces-sive pressure, clean the screen with the slightly dampened rag.Recommendation to Use more than One UnitAs unforeseen situation can occasionally occur for the monitor, when the display is used for safety control of human, equipments or unstable picture, or for emergencies, we strongly recommend you use more than one unit or prepare a spare unit.AMM261WTD   9On Burn-inPermanent burn-in may occur from the followings:   •  Displaying color bar or static images repeatedly or for a long period of time.   •  Using the unit repeatedly in a high temperature/ high humidity environment  •  Displaying an image smaller than the monitor continuously.To reduce the risk of burn- in, we recommend turning off the power of the unit, and reducing the brightness when the unit is not in use.
POWER MANAGEMENT FUNCTIONThe monitor is equipped with the power management function which automatically reduce the power consumption when not in use in three power level modes.• Stand-by ModeThe monitor goes into stand-by mode when the horizontal sync signal is off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the horizontal sync signal is restored.• Suspend ModeThe monitor goes into suspend mode when the vertical sync signal is off for about 10 seconds. The power consumption during this is 10 W. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical sync signal is restored.• Off ModeThe monitor goes into power-off mode when the vertical and horizontal sync signals are off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical and horizontal sync signals are restored.Power Management SystemThe AMM261WTD Medical Monitor power management proposal.  Provides four phases of power-saving modes by detecting the horizontal sync signal as shown in the table below.When the monitor is power saving mode or detects an incorrect timing, the screen will be blank and power LED indicator will blink.10    User’s GuideState Normal OperationDPMS StandbyDPMS Suspend DPMS OffHorizontal Sync Active Inactive Active InactiveVertical Sync Active Active Inactive InactiveVideo Active Blanked Blanked BlankedPower Indicator Green Green Flashing (1 sec. Interval)Green Flashing (1 sec. Interval)Green Flashing (1 sec. Interval)Power Consumption 50 W 10 W 10 W 10 W
PRESET MODESAMM261WTD   11ResolutionHorizontal frequency     ( KHz )Vertical frequency     ( Hz )Pixel  clock    ( MHz )640 x 350 @70Hz 31.469 70.087 25.175640 x 480 @60Hz 31.469 59.940 25.175640 x 480 @75Hz 37.500 75.000 31.500800 x 600 @56Hz 35.156 56.250 36.000800 x 600 @60Hz 37.879 60.317 40.000800 x 600 @75Hz 46.875 75.000 49.5001024 x 768 @60Hz 48.363 60.004 65.0001024 x 768 @70Hz 56.476 70.069 75.0001024 x 768 @75Hz 60.023 75.029 78.7501152 x 864 @60Hz 54.348 60.053 80.0001152 x 864 @70Hz 63.955 70.016 94.2001152 x 864 @75Hz 67.500 75.000 108.0001280 x 1024 @60Hz 63.981 60.020 108.0001600 x 1200 @60Hz 75.000 60.000 162.0001920 x 1200@60Hz  74.099 59.999 154.125DVI and VGA input signal formats
Video Signals12    User’s GuideFormat DVI  VGA/SOG Video Y/C SDI1/2Component Y/Pb/Pr RGB+ CSRGB+ HVNTSC *1 O OPAL *2 O O480/59.94i O O O O O480/59.94p O O O576/50i O O O O O576/50p O O O O O720/50p O O O O O O720/59.94p O O O O O O720/60p O O O O O O1035/59.94i O O O O O1035/60i O O O O O1080/23.98psf O O O O O1080/24psf O O O O O1080/23.98p  O O O O O1080/24p  O O O  O O1080/25p  O O O O O  O1080/29.97p  O O O O O O1080/30p  O O O O O O1080/50i  O O O O O O1080/59.94i  O O O O O O1080/60i  O O O O O O1080/50p O O O *31080/60P O O O *3*1 NTSC-M, NTSC-433*2 PAL-BDGHI, PAL-M, PAL-N, PAL-60*3 3G-SDI signal
AMM261WTD   13PIP / POP / PBP functionThe following combination options are available to you:                PIPMain VGA DVI  SDI1 SDI2 C-Video Y/C omponent/RGBs SOGVGA O O O O O O ODVI O O O O O O O OSDI1 O  O O O O O OSDI2 O O O O O O OC-Video O O O O O O OY/C O O O O O O O OComponent/RGBs O O O O O O O OSOG O O O O O O
DDCTo make your installation easier, the monitor is able to Plug and Play with your system if your system also supports DDC protocol. The DDC (Display Data Channel) is a communication protocol through which the monitor automatically informs the host system  about its capabilities, for example, supported resolutions and corresponding timing. The monitor supports DDC1 and DDC2B standard.INSTALLATIONTo install the monitor to your host system, please follow the steps as given below:Steps1. Use the supplied video cable (DVI, VGA, S-Video, C-Video) then connect to the   host system accordingly.2. Connect the DC power to the DC power connector on the monitor.3. Connect one end of AC power cord into the AC Adapter and the other end to AC   power outlet.4. Then turn the host system on and then the monitor.5. If the monitor still does not function properly, please refer to the troubleshooting   section to diagnose the problem.14    User’s GuideDVI VGA SDI INS - VideoC - Video / SOGDC PowerINOUTRGB / Component SDI OUT
CONNECTING the POWER CORD*   Check rst to make sure that the power cord you use is the correct type required for your area.*   This monitor has an universal AC adapter that allows operation in either  AC 100 - 240 V ac voltage area.  No user-adjustment is required.*   Plug one end of the power cord to the AC adapter, plug another end to a proper AC outlet.The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and marked HAR.For  120  volt Applications,  use  only  UL  Listed  deachable  power  cord  with  NEMA conguration 5-15P type  (parallel blades)  plug cap.   For 240 volt  applications use only UL Listed Detachable power supply cord with NEMA conguration 6-15P type (tandem blades) plug cap.AMM261WTD   15Hospital-grade power cordPower SupplyModel No: BPM150S24F10  AMM261WTDExtension power cord (optional)Manufacturer: BridgepowerPart No:  CB-47D2001P50MF (5ft) or                CB-47D2004P57MF (15ft) or               CB-47D2022P86MF (75ft)
16    User’s GuideUser Functions / MessagesKey Name and FunctionPower LED : Lights up to indicate the power is turned ON.Standby Power Button: To power ON or OFF the monitor.Rotary switch : With the OSD menu activated, increases the value of the selected (Turn Right)      parameter or moves rightward in OSD menu.Rotary switch : With the OSD menu activated, increases the value of the selected (Turn Left)         parameter or moves leftward in OSD menu.PIP Switch : To enable or disable Picture In Picture function.PBP Switch : To enable or disable Picture By Picture function.POP Switch : To enable or disable Picture On Picture function.Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP,              PBP, POP mode.Input Switch : To change the video source.Power Switch : To turn ON or OFF the system.How to access the menu.1. Push the “Knob” button to activate the OSD menu.2. Able to turn left or right the button to select those icons. The icon will behighlighted when is selected.3. Push the “knob” button to go into the another OSD menu.4. Turn left or right “Knob” button to increase or decrease the number of selectedfunction.5. In order to exit from the OSD menu in a different layer, then choose the “Exitoption”. In case of long pushing and holding the button around two or threeseconds, then it will completely out from the menu regardless wherever you are.6. Turn the “Knob” button in a fast way to the left or right, while the menu is notactivated, then input signal menu will turns up with “V” mark which is chosencurrent available input signal. You can switch to another input signal source byturning the knob slowly then select the target source by pushing the knob.Standby Power Button
AMM261WTD   17OSD SectionChromatic  Adjust Color Temp, GammaVisual    Adjust Brightness, Contrast, Phase, Chroma,     Sharpness-H, Sharpness-VSetting    Adjust Scale Mode, Color Space, Mirror, Freeze Frame,     Zoom / Pan, PIP, POP, PBPAdvanced  Adjust OSD Position Control, Screen Control, DPMS, Auto     Source Select, Smart Select, Restore Factory, Key Lock,     OverscanInformation  Adjust Custom Entry, SN, Run Time, Input FormatExit    Exit the menuMain Menu
18    User’s GuideOSD SectionChromaticColor Temp  Change the color temperature - D65, D93, S1, S2Gamma    Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,     2.4, 2.4S, S0, Radio graphExit    Exit the menuVisualBrightness  Adjust the brightness of panel (Range 0 - 100)Contrast   Adjust the contrast of video (Range 0 - 100)Phase    Adjust the phase of video (Range 0 - 100)  *available for C and S - videoChroma    Adjust the chroma of video (Range 0 - 100)    *available for C and S - videoSharpness-V  Set the sharpness of vertical image (Range 0 - 100)Sharpness-H  Set the sharpness of horizontal image (Range 0 - 100) Exit    Exit the menu
OSD SectionSettingScale Mode  Change the scale mode - Fill all, One to One,    Vertical - ll, Horizontal - ll, Fill aspect ratioColor Space  Change color space between RGB and YPbPr  *available for Component and RGBSMirror    Off/On mirror imageFreeze Frame  Off / On freeze frameZoom / Pan  Enable zoom - in and pan functionPIP    Enable PIP (Picture In Picture) functionPOP    Enable POP (Picture On Picture) functionPBP    Enable PBP (Picture By Picture) functionExit    Exit the menuAMM261WTD   19
20    User’s GuideOSD SectionMode    PIP Mode ON / OffSource    PIP sub screen source - SDI1/2, C-Video, S-Video,     Component/RGB, VGA, DVIPosition    PIP sub screen position - Top L, Top R, Bottom L, Bottom RSize   PIP sub screen size - Small, Medium, LargeBlending   PIP sub screen blending (Range 0 - 100)Swap    PIP sub screen swapExit    Exit the menuMode    PBP Mode ON / OffSource    PBP sub screen source - SDI1/2, C-Video, S-Video,     Component/RGB, VGA, DVISwap    PBP sub screen swapExit    Exit the menuSub menu of PBPSub menu of PIP
Mode    POP Mode ON / OffSource    POP sub screen source - SDI1/2, C-Video, S-Video,     Component/RGB, VGA, DVIPosition    POP sub screen position - Top L, Top R, Bottom L, Bottom RSize   POP sub screen size - Small, Medium, LargeBlending   POP sub screen blending (Range 0 - 100)Swap    POP sub screen swapExit    Exit the menuSub menu of POPAMM261WTD   21OSD Section
22    User’s GuideOSD Section AdvancedOSD Position  Change the OSD menu - Position, Background, Control    OSD time out, Language  Screen Control  Control and adjust H and V position, Freqency, Phase    Noise Reduction, Motion Offset  DPMS    Change the DPMSAuto Source  Adjust Auto Source Select between on and offSelectSmart Select  Enable / Disable smart select sub menuRestore Factory  Changes the all OSD value to factory outgoing statusKey Lock  Set to key lock modeOverscan  Adjust Overscan ratioExit    Exit the menu
OSD SectionSub menu of OSD ControlH-position  Adjust OSD H - position (Range 0 - 100)V-position  Adjust OSD V - position (Range 0 - 100)   Back ground  Adjust transparency of OSD back ground (Range 0 - 100)OSD Time out  Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2mLanguage  OSD language - English, Japanese, Chinese, Korean,   French, GermanExit    Exit the menuH-position  Adjust screen H - position (Range 0 - 100)  *available for VGA, SDI, ComponentV-position  Adjust screen V - position (Range 0 - 100)  *available for VGA, SDI, ComponentFrequency  Adjust frequency (Range 0 - 100)  *available for VGAPhase   Adjust phase (Range 0 - 100)  *available for VGANoise    Noise reduction (Range 0 - 100)Reduction Motion Offset  Motion offset (Range 0 - 100)  Exit    Exit the menuSub menu of Screen ControlAMM261WTD   23
24    User’s GuideOSD Section InformationCustom Entry  Change the user or monitor’s nameSN    Display the serial numberRun Time  Display the total run timeInput Format  Display the current input resolution and vertical frequencyExit    Exit the menu
TROUBLESHOOTINGBefore sending your LCD monitor for servicing, please check the troubleshooting list below to see if you can self-diagnose the problem.AMM261WTD   25Problems Current Status RemedyNo Picture LED ON ·  Using OSD, adjust brightness and contrast to maximum or reset to their default settings.LED OFF ·  Check the Standby Power Button and Power switch.·  Check if AC power cord is properly connected to the AC adapter.LED Blinking ·  Check if video signal cable is properly connected at the back of monitor.·  Check if the power to computer system is ON.Abnormal Picture  Unstable  Picture ·  Check if the specication of graphics adapter and monitor is in compliance which may be causing the input signal frequency mismatch.Display is missing, center shift, or too small or too large in display size·  Using the Screen Control Menu, adjust the Phase, Frequency, Horizontal, and Vertical settings in order to correct the display image.
26    User’s GuideSPECIFICATION** All contents are subject to change without notice.**Brightness shown is without A/R lter installed.Model AMM261WTDDescription a-Si TFT Active Matrix, LED BacklightActive Screen Size 26 inches diagonalResolution 1920 (H) x 1080 (V) @60HzPixel Pitch 0.30 mmDisplay Color 1.07B colorsColor Tone Up to 256 color toneResponse Time <25ms Typ.Face Finishing Protective Filter with Anti-Reected Hard CoatedViewing Angle R/L 178°, U/D 178° (CR > 10)Brightness** 450 cd/m2 (Typ.)Contrast Ratio 1400:1 (Typ.)Input OutputComposite Video BNC x 1 Composite Video BNC x 11.0 Vp-p 1.0 Vp-pY/C Video4 pin Mini Din x 1Y/C Video4 pin Mini Din x 1Luminance (Y) : 1.0± 0.1Vp-p Luminance (Y) : 1.0± 0.1Vp-pChrominance (C) : 0.3± 0.03Vp-pChrominance (C) : 0.3± 0.03Vp-pComponent/RGBBNC x 5 (Y/Pb/Pr , RGBs , R/G/B/H/V)Component/RGBBNC x 5 (Y/Pb/Pr , RGBs , R/G/B/H/V)RGB: 0.7 ± 0.1 Vp-p RGB: 0.7 ± 0.1 Vp-pComposite Sync : 0.3Vp-p ~ 5Vp-pComposite Sync : 0.3Vp-p ~ 5Vp-pH/V SYNC : TTL Level H/V SYNC : TTL LevelSDI1/2 3G/HD/SD SDI, BNC x1 SDI1/2 3G/HD/SD SDI, BNC x1VGA15pin D-Sub x 1R/G/B : 0.7 ± 0.1 Vp-pH/V Sync : TTL Level (V high ≥2.3V, V low ≤0.5V)DVI DVI-I x 1 Remote Input 9–pin D-Sub (RS-232C) x 1Scanning Frequency Horizontal : 31.47~80.0Khz   Vertical : 50~85HzGeneralPower Adaptor AC 100 ~ 240V 50-60Hz, 2.0ADC 24V, 6.25APower Consumption TBD WDimension 643.7(W) x 394.8 (H) x 79.8 (D) mmWeight Monitor : TBDAC adaptor : TBDVESA Mounting 100mm x 100mmOperating/Storage EnvironmentOperating Tempera-ture 32° ~ 95°F (0° - 35°C)Operating Humidity 20% ~ 80%, non-condensingStorage Temperature -4° ~ 140°F (-20° - 60°C)Storage Humidity 10 ~ 85%RH (without condensation)Compliance &CerticationSafety UL (UL60601-1), cUL (CAN/CSA-C22.2 No.6011-M90), CE (EN60601-1), AS/NZS 3200-1-0. CCC (GB4943.1), CB-ITE (IEC60950-1), IP23 ComplianceEMC FCC (Part 15 Class B), CE (EN60601-1-2), AS/NZS 3200-1-2, VCCI (Class B), CCC (GB9254, GB17625.1)Optional ModuleDC Extension Cable 5ft, 15ft, 75ft lengthBase Stand Adjustable high, swivel and tilt base stand
This monitor is intended for use in Health Care Facilities model AMM261WTDEquipment is not suitable for use in the presence of ammable anesthetic mixture with air or with oxygen or nitrous oxide.No user serviceable parts inside, ask qualied personnel when accessing inside.For disposal of waste product, follow the requirement of local code.Electrical input rating: 24V DC 6.25AClassicationType of protection against electric shock: Class I Equipment.Degree of protection against the ingress of water: IP23 compliance.Mode of operation: ContinuousThis monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2 and is certied by UL to medical standard UL60601-1(UL/cUL Mark).Because many medical ofces are located in residential areas, this monitor, in ad-dition to the medical requirements, has also been tested and found to comply with the limits for FCC Class B computing devices in a typically congured system. It is the system integrator or congurer’s responsibility to test and ensure that the entire system complies with applicable EMC laws.Environmental conditions for transport and storage:-  Temperature range within -4°  to 140° F (-20° to 60°C)-  Relative humidity range within 10% to 85%-  Atmospheric pressure range within 500 to 1060 hPa.: UL approval mark according to thesafety standard for Medical equipment: Direct CurrentMEDICAL EQUIPMENTWITH RESPECT TO ELECTRIC SHOCK,FIRE AND MECHANICAL HAZARDS ONLYIN ACCORDANCE WITH UL 60601-1, ANDCAN/CSA C22.2 NO. 601.151LJ Medical Equipment E215822AMM261WTD   27
28    User’s GuideElectromagnetic CompatibilityLike other electrical medical equipment, the AMM261WTD requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the AMM261WTD must be installed and operated according to the EMC information provided in this manual. Note   The AMM261WTD has been designed and tested to comply with IEC 60601-1-2:2001 requirements for EMC with other devices. Caution   Portable and mobile RF communications equipment may affect the normal function of the AMM261WTD. Warning   Do not use cables or accessories other than those provided with the AMM261WTD, as this may result in increased electromagnetic emis-sions or decreased immunity to such emissions. Warning    If the AMM261WTD is used adjacent to or stacked with other equipment, observe and verify normal operation of the AMM261WTD in the conguration in which it will be used prior to using it in a surgical procedure. Consult the tables below for guidance in placing the AMM261WTD. The Model AMM261WTD is intended for use in the electromagnetic environment specied below.The customer or the user of AMM261WTD should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment - guidanceRF emissions CISPR 11 Group 1The Model AMM261WTD uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipmentRF emissions CISPR 11 Class BAMM261WTD is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposesHarmonic emissions IEC61000-3-2 Class DVoltage Fluctuations IEC61000-3-3 CompliesManufacturer’s declaration - electromagnetic emissionThe Model AMM261WTD is intended for use in the electromagnetic environment specied below. The customer or the user of AMM261WTD should assure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment - guidanceElectrostatic discharge (ESD) IEC61000-4-26 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood, concrete or ceramic tile. If oors are covered with synthetic material, the relative humidity should be at least 30%.Electrical fast transient /burst IEC61000-4-42 kV for power supply lines1 kV for input / output lines2 kV for power supply lines1 kV for input / output lines Mains power quality should be that of a typical commercial or hospital environment.Surge IEC61000-4-51 kV differential mode2 kV common mode1 kV differential mode2 kV common modeMains power quality should be that of a typical commercial or hospital environment.Manufacturer’s declaration - electromagnetic immunity
Power frequency (50/60Hz) mag-netic eld IEC 61000-4-8 3.0 A/m 3.0 A/mPower frequency mag-netic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment.Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-11<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.Mains power quaility should be that of a typical commercial or hospital environment.  If the user of the AMM261WTD image intensier requires continued operation dur-ing power mains interrup-tions, it is recommended that the AMM261WTD image intensier be powered from an uninter-ruptible power supply or a battery.Note: Ut is the A.C. mains voltage prior to application of the test level.The Model AMM261WTD is intended for use in the electromagnetic environment specied below. The customer or the user of AMM261WTD should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment - guidanceConducted RFIEC61000-4-6Radiated RFIEC 61000-4-33 Vrms 150 KHz to 80 MHz3 V/m 80MHz to 2.5 GHz3 Vrms 150 KHz to 80 MHz3 V/m 80MHz to 2.5 GHzPortable and mobile RF communications equipment should be used no closer to any part of the AMM261WTD, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.Recommended Separation Distance0.15 MHz to 80 MHz80 MHz to 800 MHz800 MHz to 2.5 GHzwhere P is the maximum oputput power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from xed RF transmitters, as deter-mined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range (b).Interferency may occur in the vicinity of equipment marked with the follwing symbol:NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations.  Electromagnetic propagation is affected by absorption and             reection from structures, objects, and people.(a) Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast, connot be predicted theoretically with accuracy.  To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic site survey should be considered.  If the measured eld strength in the location in which the AMM261WTD is used exceeds the applicable RF compliance level above, the AMM261WTD should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the AMM261WTD.(b) Over the frequency range 150kHz to 80MHz, eld strengths should be less than [V1] V/m.Manufacturer’s declaration - electromagnetic immunityAMM261WTD   29
30    User’s GuideRecommended Separation Distances Between Portable and Mobile RF Communications Equi-pement and the AMM261WTD SystemThe AMM261WTD system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the AMM261WTD system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the AMM261WTD system as recommended below, according to the maximum output power of the communications equipment.Rated maximum output power (W) of transmitterSeparation distance (m) according to frequency of transmitter150kHz to 80MHzd=1.17, p80MHz to 800MHzd=1.17, p800MHz to 2.5GHzd=2.33, p0.01 0.12 0.12 0.230.1 0.37 0.37 0.741 1.17 1.17 2.3310 3.70 3.70 7.37100 11.70 11.70 23.30For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in me-ters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from structures, objects, and people.Dimension Drawing (mm) of AC Adapter
AMM261WTD   31Dimension Drawing (mm) of AMM261WTDStandby Power Button
32    User’s GuideConnectorsDC InputConnector Jack Power InputVideo Input24 pin DVI-I connector.DDWG or equivalent connector.Pin Description Pin Description Pin Description1 T.M.D.S. Data2- 11 T.M.D.S. Data1 Shield 21 NC2 T.M.D.S. Data2+ 12 NC 22 T.M.D.S. Clock Shield3T.M.D.S. Data2 Shield 13 NC 23 T.M.D.S. Clock+4 NC 14 +5V Power 24 T.M.D.S. Clock-5NC 15 Ground (for +5V) 25 Analog Red6DDC Clock 16 Hot Plug Detect 26 Analog Green7 DDC Data 17 T.M.D.S. Data0- 27 Analog Blue8 Analog V - Sync 18 T.M.D.S. Data0+ 28 Analog H - Sync9T.M.D.S. Data1- 19 T.M.D.S. Data0 Shield 29 GND(for analog signal)10 T.M.D.S. Data1+ 20 NC15 pin VGA connector.Pin Description Pin Description Pin Description1GRED 6GND 11 NC2GGREEN 7 GND 12 GSDA3 GBLUE 8 GND 13 IHS4 GND 9 G5V 14 IVS5GND 10 GND 15 GSCLS - Video connector.C - Video connector.Pin Description Pin Description1 CHROMINANCE 3 GND2LUMINANCE 4 GNDPin Description1DATA IN / OUTPin Description Pin Description1GND 4 NC2GND 5 VCC_24V3VCC_24V
AMM261WTD   33Description of WarrantyADVAN warrants to the rst Buyer (Buyer) that the product purchased when shipped in its original container will conform to ADVAN specications, and to any ADVAN approved specications furnished to ADVAN by the Buyer, and will be free of defects in materials and workmanship. ADVAN warrants that the product purchased is manufactured from new components which meet ADVAN standards, quality and specications. Subject to the conditions and limitations set forth below, ADVAN will, at its option, either repair any component of its products that prove defective by reason of improper workmanship or materials or ADVAN has the exclusive right to replace with refurbished units or with an equivalent product.  ADVAN warrants that the components used for repair, refurbished units or equivalent product will meet ADVAN standards, quality and specications.Commencement and Duration of WarrantyThe product purchased will be warranted for a period of eighteen (18) months (excluding the LCD panel, touch screen, and the protection lter) from the date of shipment. LCD panels and touch screens are warranted for a period of twelve (12) months from the date of shipment. Protection lters are not warranted as damage to the protection lter is considered to be normal wear and tear and can be replaced at Buyer’s cost.Components used for repair, refurbished units or equivalent product will be warranted for a period of twelve (12) months from the date of repair. Limitation of WarrantyThis limited warranty does not cover any damage to this product or other non-ADVAN products that results from any of the following: improper installation or operation; accident; abuse; misuse; natural disaster; war; insufcient or excessive electrical supply; abnormal mechanical or environmental conditions; any unauthorized disassembly, repair or modication; normal wear and tear;  tampering by anyone other than an ADVAN engineer or an ADVAN Authorized Service Center (ASC); the use of supplies, consumable items and conditions beyond the control of ADVAN, such as common carrier provided equipment and/or facilities; operation of ADVAN product in excess of the specications.  This limited warranty also does not apply to any product that has not been handled or packaged correctly, that has been sold as second-hand or has been resold contrary to the US export regulations, on which the original identication information (i.e. serial number, rating and/or warranty label) has been altered, obliterated or removed.
34    User’s GuideReturn Material Authorization (RMA) ProcedureAll claims must be submitted through the ADVAN website, whether in warranty or out, rst Buyer, distributor or OEM. End Users who have purchased through a distributor or OEM, please contact the distributor or OEM.http://www.advancorprma.com Follow the instructions to receive an RMA number, shipping instructions and a shipping label to be placed on the outside of the shipping container.  A serial number and a detailed reason for return are required.In-transit damage is not covered by warranty. ADVAN will only pay for the return shipment by surface transportation.Returns without an RMA number will not be accepted.For product support, please e-mail details of your inquiry including product model:service@advancorp.comIn WarrantyADVAN or its ASC will repair or replace if defective in material or workmanship without cost, for a period of eighteen (18) months, (LCD panels and touch screens for a period of twelve (12) months) after the date of shipment. Buyer must notify ADVAN or its ASC of the defect before expiration of the warranty period, and request an RMA number.  If the conguration has been modied in any manner, the product must be returned to its original conguration before any warranty service will be performed by ADVAN or its ASC. No goods are to be returned to ADVAN or its ASC without prior authorization. Buyer will be responsible for packaging (preferably original container) and shipping the defective goods to ADVAN or its ASC, shipping charges prepaid.ADVAN or its ASC will return the in warranty product, at no cost to the buyer.
AMM261WTD   35Out-of-WarrantyADVAN or its ASC will repair or replace if defective in material or workmanship with fee, any product which the warranty period has expired (out-of-warranty).Buyer must notify ADVAN or its ASC of the defect and request an RMA number.  If the conguration has been modied in any manner, the product must be returned to its original conguration before any service will be performed by ADVAN or its ASC. No goods are to be returned to ADVAN or its ASC without prior authorization. Buyer will be responsible for packaging (preferably original container) and shipping the defective goods to ADVAN or its ASC, shipping charges prepaid.ADVAN or its ASC will return the out-of-warranty product, at cost to the buyer.Product End of Life (EOL)In the event of an RMA of an EOL product(s), ADVAN will hold or store major components of its products for a period of ve (5) years, after the EOL of its products.  ADVAN shall continue to perform the service of its products as long as ADVAN holds or stores said components of the products, with reasonable charge.The forgoing Warranty and Out-of-Warranty terms apply.
36    User’s GuideDisclaimerTHE FORGOING IS THE COMPLETE WARRANTY FOR ADVAN PRODUCTS AND SUPERSEDES ALL OTHER WARRANTIES AND REPRESENTATIONS, WHETHER ORAL OR WRITTEN.  EXCEPT AS EXPRESSLY SET FORTH ABOVE, NO OTHER WARRANTIES ARE MADE WITH RESPECT TO ADVAN PRODUCTS AND ADVAN EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED HEREIN, INCLUDING, TO THE EXTENT PERMITTED BY APPLICABLE LAW, ANY WARRANTY THAT MAY EXIST UNDER NATIONAL, STATE, PROVINCIAL OR LOCAL LAW INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY ON NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARE LIMITED TO THE PERIODS OF TIME SET FORTH ABOVE.  SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY. ADVAN’S TOTAL LIABILITY UNDER THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IS LIMITED TO REPAIR OR REPLACEMENT, AND ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY.  TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, ADVAN SHALL NOT BE LIABLE TO THE PURCHASER OR END USER CUSTOMER OF AN ADVAN PRODUCT FOR ANY DAMAGES, EXPENSES, LOST DATA, LOST REVENUES, LOST SAVINGS, LOST PROFITS, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE PURCHASE, USE OR INABILITY TO USE THE ADVAN PRODUCT, EVEN IF ADVAN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY. THE LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION.
Accessory Item ListParts Name Q’ty Description Remark1AC- Adaptor 1 Model Number: BPM150S24F10Parts Number: PS-52141209002EBridgePower2VGA Cable 1 RGB 15P TO 15P, 1.8M, IVORY3 DVI cable 1 DVI-I type CABLE 29P TO 29P4 BNC Cable 1 BNC TO BNC ,1.8M/ RG58(JTC-15)5S-Video Cable 1 S-VIDEO W.2F/C/1.8M,BLACK6User’s Manual 1Rev. B7 Quick Reference Guide1Rev. A8 Power Cord*1 Medical Grade 115V, GRAY9 VESA Screw 4 BH,+,M4x10,Ni10 Extension Power Cord** 1 Part No: CB-47D2001P50MF (5ft) or              CB-47D2004P57MF (15ft) or              CB-47D2022P86MF (75ft)BridgePower* Might vary pending on region standard**Optional item, check with local representativeAMM261WTD   37Adaptor VGA Cable DVI CableBNC Cable S-Video Cable User’s ManualPower Cord*  VESA ScrewExtension Power Cord **Quick Reference Guide
DistributorADVAN Korea#605, Kolon Science Valley 2-cha, 55, Digital-ro, 34-gil, Guro-gu, Seoul, 152-728 KoreaTel  : +82 2 783 5197Fax : +82 2 868 0880Web Page : http://www.advancorp.comExclusive DistributorEIZO Corporation153 Shimokashiwano, Hakusan, Ishikawa 924-8566 JapanTel: +81 76 275 4121Fax: +81 76 275 4125Web Page : http://www.eizo.comManufacturerADVAN INT’L CORP47817 Fremont Blvd. Fremont, CA 94538, USATel  : 1 510 490 1005Fax : 1 510 490 1151Web Page : http://www.advancorp.com

Navigation menu