Advanced Control Technologies 067X-0X Two Wire Dimmer Module User Manual C 02 HOMEPRO RF MASTER CATALOG

Advanced Control Technologies, Inc. Two Wire Dimmer Module C 02 HOMEPRO RF MASTER CATALOG

Users manual

ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-011Radio Frequency Controlled, 600W, 120 VAC,Two Wire Wall Mounted Dimmer SwitchZDW120ZDW120 WALL MOUNTED DIMMERThe ZDW120 Wall Mounted Dimmer is a component of the HomePro lighting control system.   Wire the WallMounted Dimmer in place of the standard wall switch according to the diagram above and program from theWireless Controller to operate loads.   Inclusion of the ZDW120 Wall Mounted Dimmer on the ZTH100 WirelessController menu allows remote ON/OFF control and dimming of light connected.This Wall Mounted Dimmer is designed to work with other HomePro lamp and appliance controls.  Z-Wave nodesof other types can be added to the system and will also act as repeaters if they support this function of repeatingthe signal received to other modules in the system.As part of a HomePro network, the ZDW120 will also act as a wireless repeater to insure that commands intendedfor another device in the network are received.  This is useful when the device would otherwise be out of the radiorange of the wireless controller.There are no field repairable assemblies on this unit. If service is needed, the unit must be returned wherepurchased.CAUTION!  Read and understand these instructions before installing.  This device is intended for installation inaccordance with the National Electric code and local regulations in the United States, or the Canadian ElectricalCode and local regulations in Canada.  It is recommended that a qualified electrician perform this installation.To reduce the risk of overheating and possible damage to other equipment, do not install to control areceptacle, a motor operated appliance, a fluorescent lighting fixture, or a transformer-supplied appliance, butonly permanently installed incandescent lamp fixtures.  Make sure the lamp(s) to be controlled directly from thedimmer switch total no more than 600 watts.  Retain instructions for future use.INSTALLATIONCAUTION!  -  SHOCK HAZARD.  Make all connections with the POWER OFF to avoid injury to the installer or damage to the device.1.  Strip 3/4" of insulation from the ends of the conductors (if not already done) and make connec-tions as shown in the Wiring Diagram.  Note that the line side of the load must be switched.2.  Check connections to be sure they are tight and no bare conductors are exposed.3.  Make sure the load or installation does not exceed the device rating.4.  Install into an appropriately sized electrical wall box.  Scored tabs on both sides can be bent upand down their length with pliers to break off, to allow fitting in a variety of electrical box types.5.  Restore the power.HomeProRF Home AutomationSupplied with decorativeswitch plate
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-012Wire this Wall Mounted Dimmer in place of an existing wall switch according to the diagram.  See the ZTH100Wireless Controller operating instructions to add this module under the command of the Wireless Controller.Air Gap SwitchThe ZDW120 has an air gap switch on the face (lower left), that when pulled out, completely removes the poweravailable to the load (more so than simply turning the dimmer off).  This enables the lamps that are controlled bythe device to be changed with minimal danger of electrical shock.  The air gap switch must be pushed all the wayback in for the dimmer to operate the lamps again.BASIC OPERATIONLocal ControlThe ZDW120 allows the user to•   Turn ON or OFF, DIM or BRIGHTEN, the load attached.•   Add or remove the module from the Z-Wave system•   Control other Z-Wave enabled devices.Also, when a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap one the top or bottomof the switch once to satisfy those instructions. Also, quickly tapping 4 times will give you the same result withoutchanging the state of the load attached or transmitting to other Z-Wave devices.•   Tapping top of the switch turns the load attached ON.•   Tapping bottom of the switch turns the load attached OFF.•   Pressing and holding the top of the switch will brighten the load attached, and pressing and holding the bottomof the switch will dim the load.  When OFF, pressing and holding the bottom of the switch will cause the loadwill go to the minimum dim level.Note:  Upon restoration of power after a power loss, the ZDW120 defaults OFF.LED indicationThe LED on the ZDW120 will turn on when the load attached is ON.  However, the LED can be user configuredto turn ON when the load attached is OFF, if so desired, to act as a night light.Remote ControlThe ZDW120 will respond to BASIC and MULTILEVEL commands that are part of the Z-Wave system. Refer toyour controller’s instructions as to whether your controller can transmit those commands.See the information in the section titled Version (Page 6) for a complete list of commands the ZDW120 will support.ADVANCED OPERATIONProtectionThe ZDW120 supports the Protection Command.The ZDW120 can be set to any one of three Protection modes by a wireless controller. Refer to your controllerfor information on how to set the various modes of  Protection. Some controllers may only be able to set certainsettings of Protection.There are 3 modes of Protection:1.  No Protection2.  Child Protection3.  Paddle Switch totally disabledWhen Protection is set to “No Protection” mode, the ZDW120 works normally.When Protection is set to “Child Protection” mode, you will have to press the switch 3 times rapidly to control theattached load. The ZDW120 operates normally when controlled by a wireless controller.When Protection is set to “Paddle Switch totally disabled” mode, the paddle switch will not work. You will be ableto turn the load on and off only with a wireless controller, however the paddle switch can still be used to accessthe Z-Wave network.
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-013All On/All OffThe ZDW120 supports the ALL ON/ ALL OFF commands.The ZDW120 can be set to respond to ALL ON and ALL OFF commands 4 different ways.Refer to your controller for information on how to set the ZDW120 to operate in the manner you desire. Somecontrollers may be only able to set certain settings of ALL ON/ALL OFF response.The 4 different ways the ZDW120 can be setup to respond to ALL ON and ALL OFF commands are:•  ZDW120 will not respond to ALL ON or the ALL OFF command.•  ZDW120 will respond to ALL OFF command but will not respond to ALL ON command.•  ZDW120 will respond to ALL ON command but will not respond to ALL OFF command.•  ZDW120 will respond to ALL ON and the ALL OFF command (default).AssociationThe ZDW120 supports the Association command.The ZDW120 can be set to control other Z-Wave devices.  You can turn on and off, and even dim other Z-Wavedevices once they are “associated” into 1 of 4 groups within the ZDW120.Each group is turned on or off (or dimmed) by tapping or holding the switch a differing amount of times.If you associate a Z-Wave device into Group 1, you can turn that device on and off by tapping the switch on oroff once. The load attached to the ZDW120 will also turn on or off.You can brighten the controlled device by pushing and holding the top of the switch, dim by pushing and holdingthe bottom of the switch.If you associate a Z-Wave device into Group 2, you can turn that device on and off by tapping the top or bottomof the switch twice. You can brighten or dim devices by tapping the top or bottom of the switch once and then holdit down. The load attached to the ZDW120 is not affected.If you associate a Z-Wave device into Group 3, you can turn that device on by tapping the top of the switch threetimes or off by tapping the bottom of the switch three times. You can brighten devices by tapping the top of theswitch twice or dim devices by tapping the bottom of the switch twice and then hold it down. The load attachedto the ZDW120 is not affected.If you associate a Z-Wave device into Group 4, that device will be commanded to turn on or off when the ZDW120is commanded to turn on or off.  Caution: The ZDW120 will not transmit to Z-Wave devices in Group 4 if it is alreadyin the state that the Z-Wave command commanded it to.You can associate up to 5 Z-Wave devices into each of these four groups.  For instructions on how to  “associate”a Z-Wave device into one of these groups, refer to your wireless controller instructions. (If you are using theZTH100 controller, refer to the Setup Menu, Association section).A note about dimming, if you combine Z-Wave enabled dimmers and other types of Z-Wave devices in a group,place a Z-Wave enabled dimmer into the empty group 1st to ensure that the dimming operates correctly.Routing SupportThe ZDW120 is a routing slaveThe Z-Wave devices that are “associated” into Group 2 or Group 3 can be commanded from the ZDW120 viarepeater nodes. In other words, the command can be routed through nodes that are in between the Z-Wave deviceyou are trying to control and the ZDW120.This routing via repeater nodes only needs to occur when the Z-Wave device you are trying to control and theZDW120 are not within direct range of each other. You will be able to determine this is the case, if, after“associating” a Z-Wave device into a group you cannot control it with the ZDW120.For Group 2 and Group 3, if you cannot control the Z-Wave device directly from the ZDW120, you must tell theZDW120 what other Z-Wave devices are between it and the Z-Wave device you are trying to control.  You mustuse a controller to do this, so refer to your controller’s instructions on how to tell the ZDW120 this information. Thisis sometimes called “Assigning Routes”. Caution: you do not want to do this unnecessarily because the ZDW120is limited to communicating to 5 Z-Wave devices via repeater nodes. So first, be sure to determine you cannotcontrol the device directly from the ZDW120 because you can communicate up to 25 Z-Wave devices (5 in each
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-014group) from the ZDW120 without the use of repeater nodes.Z-Wave devices that you associate into Group 1 cannot be commanded through repeater nodes.Z-Wave devices that you associate into Group 2 can be commanded through repeater nodes.Z-Wave devices that you associate into Group 3 can be commanded through repeater nodes.Z-Wave devices that you associate into Group 4 cannot be commanded through repeater nodes.There can be up to 4 nodes between the ZDW120 and the Z-Wave device you are trying to command.ConfigurationThe ZDW120 supports the Configuration command.The ZDW120 can be configured to operate slightly differently than how it works when you first install it. Using theConfiguration command you can configure the following:1.  Set Ignore Start Level Bit When Transmitting Dim Command2.  Suspend Group 43.  Night Light Operation4.  Invert Switch5.  Adjust Dim RateYou can use a ZTH100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)Set Ignore Start Level Bit When Transmitting Dim Commands•   Parameter No: 1•   Length: 1 Byte•   Valid Values  = 0 or 1 (default 0)The ZDW120 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start levelembedded in it.  A dimmer receiving this command will start dimming from that start level. However, the commandalso has a bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer willignore the start level and instead start dimming from its current level. To set this bit, configure this parameter tothe value of 1.Suspend Group 4•   Parameter No: 2•   Length: 1 Byte•   Valid Values  = 0 or 1 (default 0)You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “un-associating”those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW120 from transmitting todevices that are “associated” into Group 4.It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFFand not when dimming.Disable Group 4 During a Dim Command•   Parameter 13•   Length: 1 Byte•   Valid Values = 0 or 1 (default 0)After the ZDW120 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to theZDW120’s new level. To prevent the ZDW120 from commanding the Z-Wave devices in Group 4 during thisparticular occurrence, set Parameter 13 to the value of 1.Night Light•   Parameter No: 3•   Length: 1 Byte•   Valid Values = 0 or  (default 0)The LED on the ZDW120 will by default, turn ON when the load attached is turned ON. To make the LED turn ONwhen the load attached is turned OFF instead, set parameter 3 to a value of 1.
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-015Invert Switch•   Parameter No: 4•   Length: 1 Byte•   Valid Values = 0 or 1 (default 0)To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.Ignore Start Level When Receiving Dim Commands•   Parameter No: 5•   Length: 1 Byte•   Valid Values = 0 or 1 (default 0)The ZDW120 can be set to ignore the start level that is part of the dim command, regardless of whether thecommand itself is telling the dimmer to ignore the start level or not ignore the start level embedded in the command(see Parameter 1). Setting parameter 5 to a value of 1 will cause the ZDW120 to ignore the start level and causeit to dim or brighten from its current level.Don’t Send Level Command After Transmitting Dim Commands•    Parameter 6•   Length: 1 Byte•   Valid Values = 0 or 1 (default 0)When you press and hold the bottom of the ZDW120 switch once, the Z-Wave devices that are associated intoGroup 1 are sent the Dim command. After you release the switch, the ZDW120 follows up by commanding thedevices to go to the same level of the ZDW120. The user has the ability to stop the ZDW120 from commandingthe Z-Wave devices to do this by setting parameter 6 to a value of 1.Adjusting Dim Rate•   Parameter 7-12•   Length: 1 Byte•    Valid Values: (See below)There are 3 sets of  parameters that can adjust the dimming rate of the ZDW120.1.   One set to control how fast the dim rate is when the dimmer receives a Z-Wave command (excluding ALL ON or ALL OFF command).2.   One set to control how fast the dim rate is when the dimmer is locally controlled.3.    One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command.These values can be changed instantly to allow various scenes and effects.The first of these parameters is the “dim step” (dim rate) parameter. It can be set to a value of 1 to 99. This valueindicates how many levels the dimmer will change when the timer (discussed below) expires.The second parameter is the timing (how fast the dim rate) parameter. It can be set  to a value of  1 to 255.This value indicates in 10 millisecond resolution, how often the dim level will change. For example,  if you set thisparameter to 1, then every 10mS the dim level will change. If you set it to 255, then every 2.55 seconds the dimlevel will change.With the combination of the two parameters that can control the dim rate, the dimmer can be adjusted to dim frommax to min or min to max at various speeds between 10 millisecond and 252.45 seconds (over 4.25 minutes).On/Off Command dim rate (excluding ALL ON/ALL OFF commands)Parameter 7 Dim step Parameter   (default = 3)Valid Values: 1-99Parameter 8 Dim timer Parameter  (default = 10)Valid Values: 1-255Local Control dim rateParameter 9 Dim step Parameter   (default = 3)Valid Values: 1-99
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-016Parameter 10 Dim timer Parameter (default = 10)Valid Values: 1-255ALL ON/ALL OFF dim rateParameter 11 Dim step Parameter (default = 3)Valid Values: 1-99Parameter 12 Dim timer Parameter (default = 10)Valid Values: 1-255Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Setcommand. See your controller’s instructions on how to do this (and if it supports it).All Configuration commands will be reset to their default state when the ZDW120 is reset from the Z-Wave system.PowerlevelThe ZDW120 supports the Powerlevel command.The Powerlevel command allows controllers to set and get the RF transmit power level of a node and test specificlinks between nodes with specific RF transmit power. Refer to your controller’s instructions, if it supports thiscommand, for more information. This command is typically used by professional installers.VersionThe ZDW120 supports the Powerlevel command.The ZDW120 can return version information about itself and the commands it supports.  Refer to your controller’sinstructions on how to get this information from the ZDW120.  The following is the version information for theZDW120.COMMAND_CLASS_SWITCH_MULTILEVEL Version 1COMMAND_CLASS_SWITCH_ALL Version 1COMMAND_CLASS_PROTECTION Version 1COMMAND_CLASS_ASSOCIATION Version 1COMMAND_CLASS_POWERLEVEL Version 1COMMAND_CLASS_CONFIGURATION Version 1COMMAND_CLASS_VERSION Version 1COMMAND_CLASS_MANUFACTURER_SPECIFIC Version 1COMMAND_CLASS_MARK Version 1COMMAND_CLASS_BASIC Version 1COMMAND_CLASS_SWITCH_MULTILEVEL                Version 1Manufacturer SpecificThe ZDW120 supports the Manufacturer Specific command.The ZDW120 can return Manufacturer Specific information about itself.  Refer to your controller’s instructions onhow to get this information from the ZDW120.  The following is the manufacturer specific information for theZDW120.Z-Wave Library Type ZW_LIB_SLAVE_ROUTINGZ-Wave Protocol Version 1Z-Wave Protocol Sub Version 39Application Version 1Application Sub Version 0
ZDW120 InstructionsP/D 100504HomeProby ADVANCED CONTROL TECHNOLOGIES, INC.0671-017Power 120 VAC, 60 Hz.Signal (Frequency) 908.42 MHz.Maximum Load 600W, for incandescent lamps only.Range Up to 100 feet line of sight between the Wireless Controller and /or the closestHomePro Receiver Module.Operating Temperature Range 32-104O F (0-40O C).  Indoor use only.SUC SupportThere must be a Static Update Controller in your Z-Wave system for this feature to work.  A Static Controller isone that is not moved after addition to the network.  The Static Controller can act as a gateway in the system, sinceother nodes always know its position.  The “always listening” advantage of the Static Controller is that other nodescan transmit information frames to it whenever needed.You can assign an “SUC Route” to the ZDW120. Refer to your controller’s instructions on how to do this (if itsupports it). Assigning an SUC Route to the ZDW120 allows the ZDW120 to request an update of the Z-Wavedevices that are in between it and the Z-Wave device it was trying to transmit to. The ZDW120 will only requestan update when a transmission fails.WARRANTYFor warranty and general product information visit our web site at www.act-solutions.comThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device maynot cause harmful interference, and (2) This device must accept any interference received, including interference that maycause undesired operation.FCC NOTICENote:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instructions may cause harmful interference to radio communications.  However, thereis no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interfer-ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encour-aged to try to correct the interference by one or more of the following measures:-  Increase the separation between the equipment and receiver.- Consult the dealer or an experienced radio/TV technician for help.IC NOTICEThis Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of the device.About ZDW120’s Certification (Pending)The ZDW120 has been thoroughly tested by the ETL SEMKOdivision of Intertek, a nationally recognized testing laboratory.  Thisproduct was found to be in compliance with safety standardsANSI/UL STD 1472 and CAN/CSA C22.2 No. 184.1.In addition to compliance with product safety standards, theZDW120 is also certified to comply with applicable FCC and ICrules and regulations governing RF and EMI emissions.Manufacturer ID 1 0x00Manufacturer ID 2 0x17Product Type ID 1 'D' or 0x44Product Type ID 2 'W' or 0x57Product ID 1 '2' or 0x32Product ID 2 '0' or 0x30