Advantech Co ADAM-6051W 16-Channel Digital I/O With Counter Module User Manual ADAM 6051W

Advantech Co Ltd 16-Channel Digital I/O With Counter Module ADAM 6051W

User Manual

Download: Advantech Co ADAM-6051W 16-Channel Digital I/O With Counter Module User Manual ADAM 6051W
Mirror Download [FCC.gov]Advantech Co ADAM-6051W 16-Channel Digital I/O With Counter Module User Manual ADAM 6051W
Document ID566441
Application IDnsKVBF7m/Wg6RkcOmyaz/A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize178.89kB (2236146 bits)
Date Submitted2005-07-28 00:00:00
Date Available2005-07-27 00:00:00
Creation Date2005-05-17 18:06:16
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2005-07-05 18:31:30
Document TitleMicrosoft Word - ADAM-6051W User Manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: David.Lee

ADAM-6051 16-channel Digital I/O w/Counter Module
The ADAM-6051W is a high-density I/O module built-in a 10/100 based-T interface for seamless Ethernet connectivity.
It provides 12 digital input, 2 digital output, and 2 counter (10 KHz) channels with 5000VRMS Isolating protection. All of
the Digital Input channels support input latch function for important signal handling. Mean while, these DI channels
allows to be used as 1 KHz counter. Opposite to the intelligent DI functions, the Digital Output channels also support
pulse output function.
ADAM-6051W
Figure 1: ADAM-6051W 16-channel Digital I/O w/Counter Module
ADAM-6051W Specification
• Channel: 16
• I/O type: 12DI / 2DO / 2Counter
• Digital Input: Dry Contact:
Logic level 0: Close to GND
Logic level 1: Open
Wet Contact:
Logic level 0: +3 Vmax
Logic level 1: +10 to 30 V
• Digital Output:Open Collector to 30 V, 200 mA max. load
• Optical Isolation: 5000VRMS
• Counter:
Maximum Count: 4,294,967,285(32 bit)
Input frequency: 0.3 ~ 1000 Hz max. (frequency mode), 5000 Hz max. (counter mode)
Isolation voltage: 2500 VRMS
Mode: Counter (Up/Down, Bi-direction), Frequency
• Communication: Wireless LAN IEEE802.11b
• Power Consumption: 2 W (Typical)
Application Wiring
Figure 2: ADAM-6051W Digital Input (Wet Contact) Wiring
Figure 3: ADAM-6051W Digital Input (Wet Contact) Wiring
Figure 4: ADAM-6051W Digital Output and Counter Wiring
System Architecture
ADAM-6051W Configuration
Network Configuration
Step 1 : Please open the ADAM-5000TCP-6000 utility software. The utility software will automatically
scan the ADAM-6000 modules. Please wait for the ADAM-6051W being found by utility software.
Step 2 : Please go the “Network” page to change the IP address/Subnet Address/Default Gateway of
ADAM-6051W module to be compatible with user’s existing network and set the host idle time out value
(the ADAM-6000 module can only accept 8 connection from host station. Any host station doesn’t request
the communication with this ADAM-6000 module over the time out setting, the connection of this host
station will be released for the other stations).
press “Apply” to download the new IP address to ADAM-6051W module (the default password for the
changing configuration is “00000000”).
Step 3 : Re-configuring the IP address of the configuration PC to be the original setting (compatible with
user’s existing network) then re-start the utility software. The software will automatically search the
ADAM-6051W module again.
Step 4 : Go to the “Wireless” page to set the wireless LAN configuration.
Please set the wireless LAN mode to be “Infrastructure” or “Adhoc” based on exact system architecture.
Please assign the SSID for the specific wireless AP to be connected with ADAM-6000W modules. User
can place “ANY” key to let the ADAM-6000W modules to automatically search the existing wireless AP. Or
key in the specific SSID to assign the dedicated AP (strongly recommending to set up the dedicated SSID,
it can guarantee the communication of ADAM-6000W modules to be stable)
For assigning the dedicated wireless LAN AP, user can use the site survey function to check the existing
AP in connection environment. Please go to the “Site Survey” page.
Press “Scan” bottom to search the existing AP.
Selecting the AP in the searching result table.
Press “Apply” bottom to accept the AP to finish the set up action.
Please select the region for your area.
Setting the used channel, the channel number must be included in the channel segment of your region.
Please select the basic rate for the communication bandwidth.
Press the “Apply” bottom to finish the set up work.
Step 5 : Configure the WEP security setting. Please go to the WEP page in “Wireless” of utility software.
If user want to use the WEP security function, please enable the WEP function in “User WEP” then select
the Key format and key in the WEP key for this requirement.
Step 6 : Data Stream Configuration
In addition to TCP/IP communication protocol, ADAM-6000 supports UDP communication protocol to
regularly broadcast data to specific host PCs.
Click the tab of Data Stream, then configure the broadcasting interval and the specific IP addresses which
need to receive data from the specific ADAM-6000 I/O module. This UDP Data Stream function
broadcasts up to 8 host PCs simultaneously, and the interval is user-defined from 50ms to 7 Days.
Data Stream Monitoring
After finishing the configuration of Data Stream, you can select the item “Monitor Data Stream” in the
function bar or click icon to call up operation display as below Figure.
Select the IP address of the ADAM-6000 you want to read data, then click “Start ” button. The Utility
software will begin to receive the stream data on this operation display.
Firmware/Web Page Configuration
Step 1 : Please go to the “Firmware/Web” configuration page
Step 2 : The ADAM-6000W modules support the configurable web page feature. Users don’t have to
learn the Java language to write the Java program to make the customized web page. Users can use the
utility software to easily configure the web page that you want. Please follow the below instruction to
configure the web page inside ADAM-6000W modules.
Press the web page configuration bottom.
Key in the Tag Name of input channel.
Key in the description of input channel
Press the label bottom to configure the label description of input channel.
Key in the Tag Name of output channel
Key in the description of output channel
Press the label bottom to configure the label description of output channel
Key in the Tag Name of counter channel
Key in the description of counter channel
Click the title position to configure the page title description
Please press “OK” after finishing all of the web page configuration.
Press “Update” bottom to download the web page configuration into ADAM-6000W module. And system
will save the configuration data as a file in C:\Programs\ADAM-5000TCP-6000
Utility\Program\Firmware\ADAM-6051W\ADAM6051W.Html
User can also retrieve the previous web page configuration file to download to ADAM-6000W Module.
Select the stored web page configuration file then press “Open”
Follow the above action to download the selected file into ADAM-6000W module.
Firmware Update
Step 1 : Press the browse bottom of firmware
Step 2 : Select the firmware file to be downloaded
Step 3 : Press “Update” bottom to finish the firmware update action
Input/Output Channel Configuration
Step 1 : Please click on the “6051W” to go to the ADAM-6051W configuration main page.
Step 7 : Please go to “Communication WDT” to set up the communication watchdog timer setting. This
function is used for security protect, it means sometimes, noise or other reasons will cause the
communication fail, and the host PC won’t control the modules anymore, but the modules will keep the
latest output status, and this status may cause dangerous, so while this situation happen, the
communication WDT will detect it till timeout then reset the module and set the output to safety value to
prevent the dangerous, user can set the safety value by themselves.
Step 3 : Please click on “DO:XX” to access the digital output channel configuration page. The digital
output channel of ADAM-6051W can be configured as typical DO output, pulse output, DO with LO to Hi
delay or DO with Hi to LO delay:
For typical DO setting :
For Pulse Output setting :
For “Lo to Hi delay” and “Hi to Lo delay” function :
Step 4 : Please click on “DI:XX” to access the digital input configuration page. The digital input channel of
ADAM-6068 supports typical DI, counter, frequency, Lo to Hi Latch and Hi to Lo Latch.
For typical DI setting :
For Counter setting :
For Frequency setting :
For “Lo to Hi Latch” and “Hi to Lo Latch” setting :
Step 4 : Please click on “CNT:XX” to access the counter channel configuration page.
For Counter setting :
For Frequency Mode setting :
Appendix : Adam-6000W Mode Setting
switch
Mode 1 (Normal Mode): In this mode, you can use Utility to configure module to Infrastructure or Ad hoc
mode.
Mode 2 (Diagnostic Mode): The purpose of this mode is used to recover the Adam-6000W module from
error state. User can switch module to diagnostic Infrastructure/Ad hoc mode that
has temporary wireless setting and default IP, subnet mask. Therefore, user can
re-configure the wireless setting when module’s communication is dead. (*Note:
the temporary wireless setting will be cleared after reboot to Normal mode)
Diagnostic-mode default settings:
Diagnostic Ad hoc mode setting:
Temporary SSID: WLAN
Temporary Channel: 10
Temporary Wep: No
IP: 10.0.0.1
Subnet mask: 255.0.0.0
Gateway: 0.0.0.0
Diagnostic Infrastructure mode setting:
Temporary SSID: 
Temporary Channel: 10
Temporary Wep: No
IP: 10.0.0.1
Subnet mask: 255.0.0.0
Gateway: 0.0.0.0
Assigning addresses for the ADAM-6051W Modules
ADDR 0X
CH
ITEM
Attribute
ADDR 4X
CH
ITEM
Attribute
00001
DI
40001~40002
*Counter
00002
DI
40003~40004
*Counter
00003
DI
40005~40006
*Counter
00004
DI
40007~40008
*Counter
00005
DI
40009~40010
*Counter
00006
DI
40011~40012
*Counter
00007
DI
40013~40014
*Counter
00008
DI
40015~40016
*Counter
00009
DI
40017~40018
*Counter
00010
DI
40019~40020
*Counter
00011
10
DI
40021~40022
10
*Counter
00012
11
DI
40023~40024
11
*Counter
00013
12
DI
40025~40026
12
*Counter
00014
13
DI
40027~40028
13
*Counter
00017
DO
R/W
40029~40030
00018
DO
R/W
40031~40032
00033
Counter
Start(1)/Stop(0)
R/W
40033~40034
00034
Clear Counter(1)
R/W
40035~40036
00035
Clear Overflow
R/W
00036
00037
R/W
40037~40038
00038
Clear Counter(1)
R/W
40039~40040
00039
Clear Overflow
R/W
00040
00041
R/W
40041~40042
00042
Clear Counter(1)
R/W
40043~40044
00043
Clear Overflow
R/W
00044
Latch Status/ Clear
Status
R/W
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Pulse Output
Low Level
Pulse Output
Low Level
Pulse Output
High Level
Pulse Output
High Level
R/W
Set Absolute Pulse
(0=Continue Mode)
Set Absolute Pulse
(0=Continue Mode)
R/W
Set Incremental
Pulse
Set Incremental
Pulse
00045
Counter
Start(1)/Stop(0)
R/W
00046
Clear Counter(1)
R/W
00047
Clear Overflow
R/W
00048
00049
00050
Clear Counter(1)
R/W
00051
Clear Overflow
R/W
00052
00053
00054
Clear Counter(1)
R/W
00055
Clear Overflow
R/W
00056
00057
00058
Clear Counter(1)
R/W
00059
Clear Overflow
R/W
00060
00051
00062
Clear Counter(1)
R/W
00063
Clear Overflow
R/W
00064
00065
00066
Clear Counter(1)
R/W
00067
Clear Overflow
R/W
00068
00069
00070
Clear Counter(1)
R/W
00071
Clear Overflow
R/W
00072
00073
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
Start(1)/Stop(0)
Latch Status/ Clear
Status
Counter
10
Start(1)/Stop(0)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
00074
10
Clear Counter(1)
R/W
00075
10
Clear Overflow
R/W
00076
10
Latch Status/ Clear
Status
R/W
00077
11
Counter
Start(1)/Stop(0)
R/W
00078
11
Clear Counter(1)
R/W
00079
11
Clear Overflow
R/W
Latch Status/ Clear
Status
Counter
12
Start(1)/Stop(0)
00080
11
00081
R/W
R/W
00082
12
Clear Counter(1)
R/W
00083
12
Clear Overflow
R/W
00084
12
Latch Status/ Clear
Status
Counter
13
Start(1)/Stop(0)
00085
R/W
R/W
00086
13
Clear Counter(1)
R/W
00087
13
Clear Overflow
R/W
00088
13
Latch Status/ Clear
Status
R/W
*Note : How to retrieve the counter/frequency value on Modbus address mapping
Example :
Counter(dec) = (value of 40002) x 65536 + (value of 40001)
Frequency(dec) = (value of 40001)/10 Hz
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
This Transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Any changes or modifications (including the antennas) made to this device that are not expressly
approved by the manufacturer may void the user’s authority to operate the equipment.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
CE Declaration of Conformity
0984
Is herewith confirmed to comply with the requirements set out in the Council Directive on
the Approximation of the Laws of the Member States relating to Electromagnetic
Compatibility (89/336/EEC), Low-voltage Directive (73/23/EEC) and the Amendment
Directive (93/68/EEC), the procedures given in European Council Directive 99/5/EC and
89/3360EEC.
The equipment was passed. The test was performed according to the following European
standards:
EN 300 328 V.1.6.1 (2004-04)
EN 301 489-1 V.1.4.1 (2002-04) / EN 301 489-17 V.1.2.1 (2002-04)
EN 50371: 2002
EN 60950: 2000

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2005:07:05 18:31:30+08:00
Create Date                     : 2005:05:17 18:06:16+08:00
Page Count                      : 34
About                           : uuid:c3b11d11-baac-4600-9f9e-befd65fb2c85
Producer                        : Acrobat Distiller 6.0 (Windows)
Mod Date                        : 2005:07:05 18:31:30+08:00
Creation Date                   : 2005:05:17 18:06:16+08:00
Author                          : David.Lee
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2005:07:05 18:31:30+08:00
Document ID                     : uuid:95735dcf-5dd6-4fff-b14b-e3a80f4596d5
Format                          : application/pdf
Title                           : Microsoft Word - ADAM-6051W User Manual.doc
Creator                         : David.Lee
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M82-ADAM-6051W

Navigation menu