Aeon Labs ZW080 Siren Gen5 User Manual

Aeon Labs LLC. Siren Gen5

User Manual

Aeotec by Aeon Labs Siren Gen5. Familiarise yourself with your Siren Gen5.Action Button105 dB speaker systemSafety LEDNetwork LEDQuick start.If you're using a Z-Stick:If you're using a Minimote:Removing your Siren Gen5 from a Z-Wave network.If you're using a Z-Stick:No longer just a smart home. Now you own a safe home.Siren takes the best smart home technology and uses it to help youbuild a safe home. Most smart home systems have a safety flaw: in an emergency theysend your smartphone a push notification. That means that yoursafety, and your family’s safety, depends on everyone having asmartphone, and on those smartphones being turned on, and on thepush notification being heard and read. In other words, your family’ssafety depends on a lot of things going right just when a lot of thingsare going wrong. Getting your Siren up and running is as simple as plugging it into awall socket and linking it to your existing Z-Wave ® network. Thefollowing instructions tell you how to link your Siren to your Z-Wavenetwork using Aeotec by Aeon Labs’ Z-Stick or Minimotecontrollers. If you are using other products as your main Z-Wavecontroller, such as a Z-Wave gateway, please refer to the part of theirrespective manual that tells you how add new devices to yournetwork.2.3.4.5.6.1.2.3.4.5.With your Siren now working as a part of your smart home, you’ll beable to configure it from your home control software. Please refer toyour software’s user guide for precise instructions on configuringSiren to your needs.You’re able to test your Siren’s speaker system manually. Pleasenote that the speaker system is 105 dB and very loud – werecommend only testing your Siren while wearing the necessary earprotection given you’ll need to be next to your Siren while manuallytesting it. To manually test Siren, press and hold the Action Button for5 seconds.Your Siren can be removed from your Z-Wave network at any time.You’ll need to use your Z-Wave network’s main controller to do thisand the following instructions tell you how to do this using Aeotec byAeon Labs’ Z-Stick and Minimote controllers. If you are using otherproducts as your main Z-Wave controller, please refer to the part oftheir respective manuals that tells you how remove devices from yournetwork.If you're using a Minimote:1.2.3.4.5.6.Action ButtonNetwork LED105 dB Speaker SystemSafety LEDView the expanded manual:http://aeot.ec/spprt/sirenSiren is better than that. When an emergency is happening it lets youknow. Its 105 dB Speaker System is always heard. Its super-brightLED system lights your path even when it’s dark. Its backup batterymeans that Siren keeps on working even when your power  is out or has been  purposefully cut.  Siren  provides  a  smart  home with theperfect security and safety features that it needs. Those security and safety features are matched by smart features.Siren’s speaker system can access 5 different audio alerts, allowingyour smart home to pick the alert best suited to the emergency. Thespeaker system’s volume can also be adjusted so that Siren isperfect for every space in every home. Best of all, Siren is simple toinstall. Plug Siren in, sync it to your smart home, and then enjoy thepeace of mind that comes with knowing that your smart home is nowa safe home.Decide on where you want your Siren to be placed and plug it in toa wall outlet. Its Network LED will begin to blink for 3 seconds whenyou short press and quickly release the Action Button.If your Z-Stick is plugged into a gateway or a computer, unplug it.Take your Z-Stick to your Siren.Press the Action Button on your Z-Stick.If Siren has been successfully linked to your Z-Wave network itsNetwork LED will no longer blink when you short press and quicklyrelease the Action button on Siren. If the linking was unsuccessfuland the Network LED continues to blink when you short press andquickly release the Action button, repeat the above steps.Press the Action Button on the Z-Stick to take it out of installationmode and return it to your gateway or computer. If your Z-Stick is plugged into a gateway or a computer, unplug it.Take your Z-Stick to your Siren.Press the Action Button on your Z-Stick.Press the Action Button on your Siren.If your Siren has been successfully removed from your network, itsNetwork LED will blink for 3 seconds when you short press andquickly release your Siren’s Action Button. If the removal wasunsuccessful, the Network LED will not blink.Press the Action Button on the Z-Stick to take it out of removalmode.Decide on where you want your Siren to be placed and plug it in toa wall socket. Its Network LED will begin to blink for 3 secondswhen you short press and quickly release the Action Button.Take your Minimote to your Siren.Press the Include button on your Minimote.If Siren has been successfully linked to your Z-Wave network, itsNetwork LED will no longer blink when you short press and quicklyrelease the Action Button on Siren. If the linking was unsuccessfuland the Network LED continues to blink when you short press andquickly release the Action Button repeat the above steps.Press any button on your Minimote to take it out of installationmode.1.Advanced functions.Associating dierent tones with dierence events.Your Siren contains 5 different alert tones, and each can be set to be used for a different type of emergency. One tone is more relevant  tointruder  alerts,  while others  are more relevant  to the likes of water leaks,  medical emergencies and door chimes. This functionality can be setup and  configured via  supporting  Z-Wave  gateways. Please refer to your gateway's user manual for further information.
Version: 501008000001-AAFCC NOTICE (for USA)Resetting your Siren Gen5Built-in Lithium Battery: 430 mAh.Alarm Power: 1.7W.Max Standby Power: 0.7W.Max Volume: 105 dB, reduced in battery powered mode.Operating Temperature: 0-45ȭOperating Distance: Up to 550 feet/170 metres outdoors.61.2.3.4.5.At some stage, you may wish to reset all of your Siren’s settings totheir factory defaults. To do this, press and hold the Action Button for20 seconds and then release it. Your Siren will now be reset to itsoriginal settings, and the speaker system will sound for 3 seconds asa confirmation.Excluded from the warranty are problems due to accidents, acts ofGod, civil or military authority, civil disturbance, war, strikes, fires,other catastrophes, misuse, misapplication, storage damage,negligence, electrical power problems, or modification to theProducts or its components. Aeon Labs does not authorize any person or party to assume orcreate for it any other obligation or liability in connection with theProducts except as set forth herein. Aeon Labs will pass on to Customer all manufacturers’ Materialwarranties to the extent that they are transferable, but will notindependently warrant any Material.Customer must prepay shipping and transportation charges forreturned Products, and insure the shipment or accept the risk of loss or damage during such shipment and transportation. Aeon Labs willship the repaired or replacement products to Customer freightprepaid.Customer shall indemnify, defend, and hold Aeon Labs and AeonLabs' affiliates, shareholders, directors, officers, employees,contractors, agents and other representatives harmless from alldemands, claims, actions, causes of action, proceedings, suits,assessments, losses, damages, liabilities, settlements, judgments,fines, penalties, interest, costs and expenses (including fees anddisbursements of counsel) of every kind (i) based upon personalinjury or death or injury to property to the extent any of the foregoingis proximately caused either by a defective product (including strictliability in tort) or by the negligent or willful acts or omissions ofCustomer or its officers, employees, subcontractors or agents, and/or(ii) arising from or relating to any actual or alleged infringement ormisappropriation of any patent, trademark, mask work, copyright,trade secret or any actual or alleged violation of any other intellectualproperty rights arising from or in connection with the products, exceptto the extent that such infringement exists as a result of Aeon Labs'manufacturing processes.1.This device may not cause harmful interference, and2.THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIOOR TV INTERFERENCE CAUSED BY UNAUTHORIZEDMODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:Take your Minimote to your Siren.Press the Remove Button on your Minimote.Press the Action Button on your Siren.If your Siren has been successfully removed from your network, its Network LED will blink for 3 seconds when you short press and quickly release your Siren’s Action Button. If the removal was unsuccessful, the Network LED will not blink.Press any button on your Minimote to take it out of removal mode.This device must accept any interference received, including interference that may cause undesired operation. This equipment  has been  tested  and  found  to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  reasonable  protectionagainst  harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequencyenergy and,   if   not  installed  and  used in accordance  with theinstructions, may cause harmful interference to radio communicationsHowever, there  is  no guarantee that interference will not occur in a  particular installation.  If  this  equipment does  cause  harmful interference to radio or  television   reception, which  can  bedetermined  by  turning  the  equipment off  and on,  the user  isencouraged  to try to correct the  interference by one or  more  of Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as defined below), the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer. Warranty claims must be made by Customer in writing within thirty (30) days of the manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the purchase price to Customer. The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under Aeon Labs' RMA policy. Any repairs conducted by unauthorized persons shall void this warranty.IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING  IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED.  ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY.THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.Contact your local government for information regarding the collection systems available.Warranty.Model number: ZW080Version Working bandUS 120V 60Hz,Max:30mA 908.42MHzEU 230V 50Hz,Max:30mA 868.42MHzAU 230V 50Hz,Max:30mA 921.42MHzUK 230V 50Hz,Max:30mA 868.42MHzIN 230V 50Hz,Max:30mA 865.20MHzCN 220V 50Hz,Max:30mA 868.40MHzIL 230V 50Hz,Max:30mA 916.02MHzBR 220V 60Hz,Max:30mA 921.42MHzInput(Standby Power)the following measures: Technical speccations.RemoveZ-Wave  and  Z-Wave Plus  are  registered  trademarks of  Sigma Designs and its subsidiaries in the United States and other countries

Navigation menu