AeroScout CGSHGS1000 HUGS WI-FI TAG CHARGER User Manual USERS MANUAL

AeroScout HUGS WI-FI TAG CHARGER USERS MANUAL

USERS MANUAL

Download: AeroScout CGSHGS1000 HUGS WI-FI TAG CHARGER User Manual USERS MANUAL
Mirror Download [FCC.gov]AeroScout CGSHGS1000 HUGS WI-FI TAG CHARGER User Manual USERS MANUAL
Document ID2113554
Application IDJR5xQ7l80m7XVz5vh1njjg==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize106.6kB (1332487 bits)
Date Submitted2013-11-07 00:00:00
Date Available2013-11-07 00:00:00
Creation Date2013-08-22 10:28:23
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2013-08-27 10:16:04
Document TitleUSERS MANUAL
Document CreatorAdobe InDesign CS6 (Windows)

Hugs® Wi-Fi Tag Charger
User Guide

Table of Contents
Introduction
Overview
Model Numbers
Intended Use
Safety Considerations
Documentation
Orientation
General Description
Operating and Display Modes
Installing the Charger
Wall Mounted
Setting Up the Charger
Using the Charger
Inserting the Tag into the Charger
Removing the Tag from the Charger
Specific Charging Capabilities
10
Overview
10
Dimensions and Weight
10
Hugs Tags States
Hugs Tag Behavior with Sensor Alarm
Hugs® Wi-Fi Tag Charger User Guide
11
12
iii

Maintenance
13
Operational Checks
13
Cleaning Instructions
13
Supplies and Accessories
15
Compliance and Safety
16
iv
Hugs® Wi-Fi Tag Charger User Guide
Introduction
Introduction
Overview
The Hugs on MobileView software notifies the users when the Hugs Tag
battery is getting low. Placing the Hugs Tag in the charger erases all the
history data from the tag, including the Kisses® bonding and the tag
status. It also triggers MobileView to erase the specific patient admitting
information.
Model Numbers
The Hugs Tag Charger part number:
• CGS-HGS-1000
Based on the power supply outlet type:
• CGS-HGS-1000-U
U.S. outlet
• CGS-HGS-1000-E
European outlet
• CGS-HGS-1000-J
Japanese outlet
• CGS-HGS-1000-UK
U.K. Outlet
Intended Use
The Hugs Wi-Fi Tag Charger is intended for facility staff who are using the
Hugs Wi-Fi Tags in conjunction with the MobileView security application.
Safety Considerations
• Position any trailing wires so that they are not a trip hazard and are less
likely to get damaged.
• Check that the plug is not damaged and that the cable is properly
secured with no internal wires visible.
• Where there is evidence that the supply may not be safe, such as
damaged equipment or wiring, the supply should not be used until work
has been done to correct this.
Documentation
Please refer to the following document for technical specifications for the
Hugs Wi-Fi Tag Charger.
•
Hugs Wi-Fi Tag Charger Data Sheet p/n 0971-063-000
Hugs® Wi-Fi Tag Charger User Guide
Orientation
Orientation
General Description
This section describes the parts and LEDs on the Charger.
POWER
SOCKET
ON/OFF
SWITCH
CHARGER
STATUS
CHARGING
LED
CHARGING
METALS
Power Socket
The power socket is located at the top-left side of the Charger. An external
power supply is provided with the Charger. For more information about the
power supply, see “Supplies and Accessories” on page 15.
Hugs® Wi-Fi Tag Charger User Guide
Orientation
ON/OFF Switch
After the Charger is plugged in, press the ON/OFF switch to the ON position.
When the Charger is not being used, press the switch to the OFF position.
Charger Status LED
The Charger status LED is located at the top-right on the front of the
Charger. When the Charger is plugged in and turned on, the Charger status
LED turns YELLOW.
Hugs® Wi-Fi Tag Charger User Guide
Orientation
Charging LED for Hugs Tag
CHARGING LED:
Yellow when the Hugs Tag
is correctly placed in the
Charger
Each Hugs Tag impression in the Charger has its own charging LED (24
LEDs in total). There are three (3) available colors for the LEDs: GREEN,
YELLOW and RED. For more information about the LED color indications, see
“Operating and Display Modes” on page 5.
Charging Metals
The charging metals are located on either side of the inside of the Hugs Tag
impression. Charging for the Hugs Tag only begins once the charging metals
are in contact with the metal in the tag slots
Hugs® Wi-Fi Tag Charger User Guide
Orientation
Operating and Display Modes
The following table describes the LED indications for the Hugs Tag Charger.
Color
Description
GREEN
Battery is fully charged.
YELLOW
Charging in progress.
RED FLASHING
Issue with the Hugs Tag. Remove and replace the tag.
RED SOLID
Issue with the Charging slot. It is not necessary to unplug the
Charger. An error may possibly be cleared by switching the
Charger OFF then back ON again. If the issue continues, do not
use the specific Charging slot. Other slots can be used for charging.
Please contact Support.
OFF - NO COLOR
LED is does not turn on when the tag is placed in the slot– Remove
the tag and replace it with a different tag. If the LED is still off, place
the tag in another charging slot. If the LED is on (GREEN or AMBER) in
the new slot then the problem is with the first charging slot. Do not
use this slot to charge tags. If the LED in the new charging slot is off
as well, then there is an issue with the tag. Discard the tag.
YELLOW
Located near the ON/OFF switch indicating the Charger is ON.
Hugs® Wi-Fi Tag Charger User Guide
Installing the Charger
Installing the Charger
The following items are included with the Hugs Tag Charger:
•
two (2) #6 Philips head screws
•
two (2) plastic wall anchors
•
Mounting plate
Wall Mounted
1.
Establish a location on the wall for the Hugs Tag Charger.
2.
Draw two (2) holes on the wall, at a level distance 262 mm apart,
from center to center.
3.
Drill two holes at the marked locations on the wall.
4.
Insert the plastic wall anchors in the drilled holes.
5.
Mount the plate and align the anchor holes with the wall anchors.
6.
Using the supplied Philips head screws, securely screw the plate to
the wall.
7.
Optionally, use wood screws or other suitable wall mount hardware
in the remaining holes on the plate.
8.
Slide the Hugs Tag Charger onto the plate to mount it on the wall.
Hugs® Wi-Fi Tag Charger User Guide
Setting Up the Charger
Setting Up the Charger
1.
Plug the supplied power cable into the power socket located on the
side of the Charger.
2.
Plug the other end into the wall external outlet (at least 12VDC @
3A).
3.
Press the ON/OFF switch to the ON position.
4.
The Charger status LED turns YELLOW indicating that the Charger is
now ready for use.
Hugs® Wi-Fi Tag Charger User Guide
Using the Charger
Using the Charger
Inserting the Tag into the Charger
1.
Ensure the Hugs Tag is clean to prevent contamination to the
Charger.
2.
Aim the bottom of the Hugs Tag towards the small bump located in
the inferior portion of the tag impression in the Charger.
3.
Push the tag and align the band slots to the charging metals.
Hugs® Wi-Fi Tag Charger User Guide
Using the Charger
4.
Push down firmly to insert the tag into the impression.
5.
The status LED turns YELLOW, indicating that the Hugs Tag is now
charging.
Removing the Tag from the Charger
1.
Push the tag towards the small bump and lift the tag out of the
impression.
Hugs® Wi-Fi Tag Charger User Guide
Specific Charging Capabilities
Specific Charging Capabilities
Overview
The battery charging process does not harm the Hugs Tag or its operational
characteristics.
Charging the Hugs Tags that are connected (up to 24 units) to the Charger
takes approximately 3 hours. Once charged, the Hugs Tag can be used for
approximately 2 weeks. It is, however, recommended to place the Hugs Tag
in the Charger between uses (ensure the tag is thoroughly cleaned first!).
The Charger updates (through an LF command) each of the tags “in charger”
current battery capacity. This update is performed in steps of 5-10% until
fully charged (100%).
The Charger transmits the following information to the tag:
•
Charger ID
•
Slot #
•
Battery charging status
•
Date/time
•
Tag MAC address
Note: The Charger is mechanically built to prevent tags from being inserted
in the wrong direction.
Dimensions and Weight
•
Size: 300 x 250 x 100 mm
•
Weight: 1 kg (not including the tags which by themselves can weigh 1 kg)
10
Hugs® Wi-Fi Tag Charger User Guide
Hugs Tags States
Hugs Tags States
State
Dormant
In-Charger
Description
•
•
Initial state after manufacturing
When the tag is not in use
When the Hugs Tag is placed in the charger:
• The Kisses bond information is automatically cleared.
• A Hugs Tag In-charger mode does not sense bands. Note: The
tag must be removed from the charger to allow insertion of a
•
band.
Three Wi-Fi messages (assuming the tag has enough battery
to transmit these messages) are transmitted indicating that the:
-Hugs Tag is in the charger
-Bonding status is erased
--
Hugs Tag is asleep
The Hugs Tags exit charging mode and enters into normal sleep mode when
they are removed from the Charger (even if they are not fully recharged).
Normal
•
•
•
•
When the tag is not in use
Kisses ignored
When it is ready to be activated
When it can be connected to a Charger
Active
•
The Hugs Tag is on a baby
- Band
•
Able to bond in accordance to the bonding status:
Sleep
Connected
--
•
Active
Alarm Band Cut
Sleep Alarm
Able to bond
-Bonded
-Not bonded (unable to bond)
Kisses accepted
During a alarm from the band being cut, the following is true for the
Hugs Tag:
• The tag is NOT on a baby
• The tag is able to bond in accordance to the bonding status:
-Able to bond
-Bonded
-Not bonded (unable to bond)
• Kisses accepted. Band can be reconnected
• Can be connected to Charger
When the Hugs Tag alarms during sleep mode, the following is true:
• The tag is NOT on baby
• Unable to bond
• Kisses ignored
• Band can be reconnected
• Can
be Guide
connected to Charger
11
 ugs® Wi-Fi Tag Charger
User
- Band Cut
Hugs Tags States
Hugs Tag Behavior with Sensor Alarm
The Hugs tag handles alarms with a priority as follows:
1. LF Exciter message (Door Exciter or Kisses)
2. Tamper event
3. Kisses mismatch event
4. Standard Wi-Fi messages
5. Proximity event
6. Other event
12
Hugs® Wi-Fi Tag Charger User Guide
Maintenance
Maintenance
Operational Checks
It is recommended to verify all LEDs are working by placing a Hugs Tag in
each of the impressions, at least once a week. If, at any time, an LED fails
to light up (even when you switch the Charger Off then On again), contact
Support.
Cleaning Instructions
The Hugs Tag Charger can be cleaned using a soft bristle brush. Follow these
guidelines for cleaning the Charger:
•
First, consult with your Infection Control representative for cleaners
available to your hospital that have been approved for use on plastics.
•
Use a disinfectant with no more than 20% alcohol or enzymatic cleaners
with a mild pH such as Enzol or Maxizyme.
•
Do not use pathogenic cleaners specified for TB.
•
Do not soak the Charger.
•
Do not use an autoclave to clean the Charger or serious damage may
result.
Please refer to the table on the following page as a guideline for suggested
cleaning materials and their preparation amounts.
NOTE: Cleaning products are currently being tested on the Charger. This
document will be updated once the results are tabulated.
Hugs® Wi-Fi Tag Charger User Guide
13
Maintenance
Solution
Manufacturer
Preparation
1.
Super Edisonite
S. M. Edison Chemical Co
Per manufacturer's recommendation
2.
Vesphene® Iise
Calgon Vestal Laboratories
Per manufacturer's recommendation
3.
Manu-Klenz
Calgon Vestal Laboratories
Per manufacturer's recommendation,
(0.25 – 0.5 oz/gallon water)
4.
Coverage™ HBV
Calgon Vestal Laboratories
Per manufacturer's recommendation
5.
Formula C™
Diversey Corporation
Per manufacturer's recommendation
6.
Sporicidin®
Sporicidin International
Per manufacturer's recommendation
7.
Precise
Caltech
Per manufacturer's recommendation
8.
Dimension III
Butcher's
0.5 oz/gallon water
9.
Expose II 256
Diversey Corporation
0.5 oz/gallon water
10.
LpH Disinfectant
Cleaner
Steris
0.5 oz/gallon water
11.
Phenolic 256 DC
Coastwide Lab
0.5 oz/gallon water
12.
Thymocide
Wexford Labs, Inc.
0.5 oz/gallon water
13.
Asepti-zyme
Huntington
1 oz/gallon water
14.
Detergezyme
Metrex
1 oz/gallon water
15.
Maxima 128
Brulin
1 oz/gallon water
16.
Metrizyme
Metrex
1 oz/gallon water
17.
Wexcide 128
Wexford Labs, Inc.
1 oz/gallon water
18.
Professional Amphyl
Hospital Bulk Disinfectant Cleaner
Reckitt Benckiser
1.28 oz/gallon water
19.
Virkon
DuPont
1.28 oz/gallon water
20.
Wexcide-Ready-ToUse
Wexford Labs, Inc.
Ready to use
21.
Hibiclens
25.6 oz/gallon water
22.
Staph-Attack
Not Applicable
23.
Compublend II (Base
V with fragrance)
3M
24.
Neutral QUAT
Disinfectant Cleaner
Concentrate
3M
14
Hugs® Wi-Fi Tag Charger User Guide
Supplies and Accessories
Supplies and Accessories
The Hugs Tag Charger is shipped with the following components:
•
110/220V AC (autoselect)
•
External power supply: at least 12VDC @ 3A
•
Power cable (3 meters*) replaceable and country-specific for the
following areas:
•
--  Argentina
--  Australia
--  China
--  Europe (except Italy, Switzerland, and United Kingdom)
--  Italy
--  Japan
--  North America
--  South Africa, United Arab Emirates, India
--  South Korea
--  Switzerland
--  United Kingdom
Folded base (for inclined standing option)
•
Two (2) #6 Philips head screws
•
Two (2) plastic wall anchors
•
Mounting plate
*Note: In North America, AC power cords must not exceed 4.5 meters
(approximately 14.75 feet) in length, to comply with National Electrical Code
(NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52 and Canadian Electrical
Code (CEC) Section 4-010(3).
Hugs® Wi-Fi Tag Charger User Guide
15
Compliance and Safety
Compliance and Safety
• UL 60950
• EN 60950 - Directive – RTTE (1999/5/EC)
• LVD (2006/95/EC)
• UL STD 294
• IEC/EN 60601-1-3
• ISO 14971
• ROHS (Directive 2011-65-EU/EC)
Federal Communication Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna.
2) Increase the separation between the equipment and receiver.
3) Connect the equipment to an outlet on a circuit different from that to which
the receiver is connected.
4) Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate
the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada
licence-exempt RSS standard(s). Operation is subject to two conditions: (1)
This device may not cause harmful interference, and (2) this device must
accept any interference that may be received or that may cause undesired
operation.
Le present appareil est conforme aux CNR d’Industrie Canada applicables
aux appareils radio exempts de licence. L’exploitation est autorisee aux
deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioelectrique
16
Hugs® Wi-Fi Tag Charger User Guide
Compliance and Safety
subi, meme si le brouillage est susceptible d’en compromettre le
fonctionnement.
Hugs® Wi-Fi Tag Charger User Guide
17
Compliance and Safety
18
Hugs® Wi-Fi Tag Charger User Guide

Hugs® Wi-Fi Tag Charger User Guide
19
About STANLEY Healthcare
STANLEY Healthcare provides over 5,000 acute care hospitals and 12,000
long-term care organizations with enterprise solutions that transform safety,
security and operational efficiency. The STANLEY Healthcare EcoSystem
enables customers to achieve organizational excellence and superior care
in five critical areas: Patient Safety, Security & Protection, Environmental
Monitoring, Clinical Operations & Workflow and Supply Chain & Asset
Management. These integrated solutions are complemented by consulting,
training and Transformational Lean™ process reengineering. STANLEY
Healthcare is proud to be part of Stanley Black & Decker, Inc.
For more information, visit www.stanleyhealthcare.com.
STANLEY Healthcare
130 Turner Street, Waltham, MA 02453
Phone: +1-888-622-6992
Email: stanleyhealthcare@sbdinc.com
© 2013 STANLEY Healthcare. All rights reserved. Doc Part # 0980-041-000 Rev 01. 07/2013.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2013:08:22 10:28:23-04:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2013:08:27 10:16:04+03:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2013:08:27 10:16:04+03:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:ca3c200f-9c98-409e-ae7a-1383e01769fe
Original Document ID            : xmp.did:FC7F1174072068118083D7EE35A2B440
Document ID                     : xmp.id:153E1414370BE311A4C59379A22958FF
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:143E1414370BE311A4C59379A22958FF
Derived From Document ID        : xmp.did:01530F9108D9E2119A1FB548233263C4
Derived From Original Document ID: xmp.did:FC7F1174072068118083D7EE35A2B440
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:08:22 10:28:23-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 24
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3HCGSHGS1000

Navigation menu