AeroScout EX3300 Hand Hygiene Integrated Exciter EX-3300 User Manual

AeroScout Hand Hygiene Integrated Exciter EX-3300

Contents

User Manual

Download: AeroScout EX3300 Hand Hygiene Integrated Exciter EX-3300 User Manual
Mirror Download [FCC.gov]AeroScout EX3300 Hand Hygiene Integrated Exciter EX-3300 User Manual
Document ID2606174
Application IDL9vuglzOQQUNZb9QFaYJGw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize64.23kB (802838 bits)
Date Submitted2015-05-06 00:00:00
Date Available2015-05-06 00:00:00
Creation Date2015-04-13 15:46:18
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2015-04-13 15:46:22
Document TitleEX3300 Series Exciter Installation & Configuration Guide
Document CreatorAcrobat PDFMaker 10.1 for Word
Document Author: daniel.pearlman@aeroscout.com

EX3300 SERIES EXCITERS
INSTALLATION & CONFIGURATION GUIDE
Disclaimer
The information and know-how included in this document are the exclusive property of STANLEY Healthcare
and are intended for the use of the addressee or the user alone. The addressees shall not forward to another
their right of using the information, know-how or document forwarded herewith, in whole or in part in all
matters relating or stemming from or involved therein, whether for consideration or without consideration,
and shall not permit any third party to utilize the information, know-how or the documents forwarded
herewith or copies or duplicates thereof, unless at the company’s consent in advance and in writing. Any
distribution, advertisement, copying or duplication in any form whatsoever is absolutely prohibited. The
Company reserves the right to sue the addressee, user and/or any one on their behalves, as well as third
parties, in respect to breaching its rights pertaining to the intellectual rights in particular and its rights of
whatever kind or type in the information, know-how or the documents forwarded by them herewith in
general, whether by act or by omission.
This document is confidential and proprietary to STANLEY Healthcare and is not to be distributed to any
persons other than licensed AeroScout Visibility System users or other persons appointed in writing by
STANLEY Healthcare.
Trademark Acknowledgements
AeroScout is a trademark of Stanley Black & Decker, Inc. or its affiliates. Other brand products and service
names are trademarks or registered trademarks of their respective holders. Below is a partial listing of other
trademarks or registered trademarks referenced herein:
Cisco™ is a trademark of Cisco Systems, Inc.
Sun, Sun Microsystems, the Sun Logo, Java, JRE and all other Sun trademarks, logos, product names, service
names, program names and slogans that are referred to or displayed in this document are trademarks or
registered trademarks of Sun Microsystems, Inc. in the United States and other countries.
This product includes software developed by the Apache Software Foundation (http://www.apache.org/).
This product includes code licensed from RSA Data Security
Skype, SkypeIn, SkypeOut, Skype Me, the Skype Logo and the S logo and other marks indicated on Skype’s
website are trademarks of Skype Limited or other related companies.
ESper is a trademark of EsperTech, Inc.
Jboss is a trademark of Red Hat Middleware, LLC.
Oracle 10G is a registered trademark of Oracle Corporation and/or its affiliates.
MS SQL Server 2005 is a registered trademark of Microsoft Corporation in the United States and/or other
countries.
JasperSoft, the JasperSoft Logo, JasperReports, the JasperReports logo, JasperIntelligence, JasperDecisions,
JasperAnalysis, Scope Center, Scope Designer, and JasperServer are trademarks or registered trademarks of
JasperSoft, Inc. in the United States and other countries.
2015 STANLEY Healthcare. All rights reserved.
Doc: 0981-184-000 Rev A
Published: 2015/04/02
KB Article: 5587
EX3300 Series Exciter Installation & Configuration Guide
Table of Contents
Introduction .........................................................................................................4
EX3300 Features ...................................................................................................5
Supported Dispenser Models ...............................................................................6
Installing the Exciters ...........................................................................................7
Adding the Exciters to the Engine Manager ..................................................... 18
Advanced Configuration ....................................................................................20
Replacing a Malfunctioning Exciter................................................................... 21
EX3300 Series Exciter Models and Cables Summary.......................................... 22
EX3300 Specifications.........................................................................................23
EX3300 Series Exciter Installation & Configuration Guide
Introduction
The EX3300 Series Embedded Exciters are key components of STANLEY
Healthcare’s Hand Hygiene Compliance Monitoring Solution. Together with
STANLEY Healthcare’s suite of enterprise visibility solutions, the EX3300 Exciters
provide robust and sophisticated RFID detection and monitoring capabilities.
The EX3300 Exciters are designed specifically to be embedded in touch free or
automated Hand Hygiene dispensers. When a dispenser with an embedded
EX3300 Exciter is activated, the Exciter triggers a tag located in range of the
Exciter and the tag in turn transmits a message to a location receiver or
compatible access point in range. This provides instant acknowledgment that a
tagged staff member has used the dispenser. The Hand Hygiene Compliance
Monitoring Solution detects, records, and reports dispenser usage by staff
member, providing a revolutionary way for healthcare facilities to monitor staff
compliance with the hand hygiene policy.
Figure 1: EX3300 embedded in a dispenser triggering a staff tag
Introduction
EX3300 Series Exciter Installation & Configuration Guide
EX3300 Features
Hand Hygiene Dispenser Integration
EX3300 Exciters are designed to be embedded in specific touch free or
automated GoJo or Ecolab dispensers. The embedded Exciter reacts to dispenser
activation and triggers the tag, in range, to transmit a message.
Configurable Transmission Range
EX3300s have a range of up to2 meters (6.5 ft.) which can be configured using
the Exciter Manager Tool.
Exciter Type Identification
EX3300 Exciters are configured with a predefined message identifying them as
Hand Hygiene devices. The triggered tag transmits the message over the
network. MobileView identifies the message as a Hand Wash event.
EX3300 Features
EX3300 Series Exciter Installation & Configuration Guide
Supported Dispenser Models
The EX3300 Exciters are designed for integration in the following GoJo and
EcoLab dispensers.
Image
Description
GOJO TFX Touch Free Dispensers
Includes the following TFX dispenser brands:
•
PURELL TFX Touch Free Dispenser
•
PURELL Surgical Scrub TFX Touch Free Dispenser
•
PROVON TFX Touch Free Dispenser
GOJO LTX Touch Free Dispensers
GOJO TFX Provon with CHG Dispensers
EcoLab Next Gen Touch-Free Dispenser
EcoLab NEXA Touch-Free Dispensers
Supported Dispenser Models
EX3300 Series Exciter Installation & Configuration Guide
Installing the Exciters
This chapter describes how to install the EX3300 Exciters in the different
dispenser models. Each dispenser model is compatible with a specific EX3300
Exciter model.
Note
The EX-3300 Exciter must only be installed in the EcoLab Hand Sanitizer
Dispenser or the GoJo Hand Sanitizer Dispensers.
Installing the EX3300 Exciter in an EcoLab Next Gen Dispenser
To open the dispenser:
1.
Press the large button situated on the bottom of the dispenser. This
releases the (bottom) hinged dispenser outer casing from the back panel,
allowing it to open forwards.
Note
Approach the dispenser from the side, being careful not to activate the
dispensing mechanism.
To Install the EX3300 Exciter:
1.
Remove the tape from the double sided Velcro on the back of the Exciter
casing.
2.
Align the positioning nodes on the Exciter casing with the holes on the
dispenser's front panel and fix the Exciter in place.
Installing the Exciters
EX3300 Series Exciter Installation & Configuration Guide
To attach the Exciter Connector Cable:
3.
Connect the black connector of the connector cable into the Exciter.
4.
Remove the entire internal dispenser mounting assembly from the
dispenser casing by depressing the holding clip on the top of the assembly.
5.
Route the cable over the top of the assembly ensuring the cable is not
snagged or twisted.
6.
Apply the connector wire retaining tape to the top of the mounting
assembly.
Installing the Exciters
EX3300 Series Exciter Installation & Configuration Guide
7.
Connect the white connector in the socket provided on the back of the
mounting assembly.
8.
Replace the dispenser mounting assembly in the case.
Installing the Exciters
EX3300 Series Exciter Installation & Configuration Guide
To Install the Soap Container:
The soap dispenser is installed with the offset dispensing nozzle on the bottom
of the container positioned facing forwards.
1.
Remove the protective cap covering the dispensing nozzle
2.
On the dispenser tilt the white cylindrical nozzle mount forwards.
3.
In the tilted position align and insert the dispenser nozzle in the cylindrical
mount.
4.
Once aligned push the soap container into the vertical position, locking
the container in place.
5.
After replacing the soap dispenser and/or the Exciter, close the dispenser
casing and test the both the dispensing mechanism and Exciter operation.
Installing the Exciters
10
EX3300 Series Exciter Installation & Configuration Guide
Installing the EX3300 in an EcoLab NEXA Dispenser
To open the dispenser:
1.
Simultaneously press the two buttons situated on both sides of the
dispenser. This releases the front of the dispenser's outer casing, allowing
it to open forwards.
To Install the EX3300 Exciter:
2.
Remove the tape from the double sided Velcro on the back of the Exciter
casing.
3.
For the standard NEXA dispenser, place the Exciter vertically on the front
panel of the dispenser.
4.
For the compact NEXA dispenser, place the Exciter horizontally on the
internal side panel of the dispenser.
Installing the Exciters
11
EX3300 Series Exciter Installation & Configuration Guide
Figure 2: Exciter placement in NEXA standard (right) and NEXA Compact (left)
To attach the Exciter Connector Cable:
1.
Connect the black connector of the connector cable to the Exciter.
2.
Remove the soap container if needed.
3.
Insert the white connector into the socket provided on the front of the
dispenser. A protective rubber cover may need to be removed from this
socket before inserting the connector.
Installing the Exciters
12
EX3300 Series Exciter Installation & Configuration Guide
4.
After replacing the soap container, close the dispenser casing and test
both the dispensing mechanism and Exciter operation.
Installing the Exciters
13
EX3300 Series Exciter Installation & Configuration Guide
Installing the EX3300 in a GOJO TFX Dispenser
To open the dispenser:
1.
Open the dispenser by pressing the large button situated on the bottom of
the dispenser. This releases the (bottom) hinged outer casing of the
dispenser, from the back panel, allowing it to open forwards.
Note
Approach from the side, being careful to not activate the dispensing
mechanism.
To install the Exciter:
1.
Remove the soap container if needed.
2.
Remove at least one of the batteries in the dispenser to disable the power.
3.
Insert the Exciter in the slot provided. A grey plug may be located in the
connector slot. This plug must be removed before the Exciter can be
inserted.
Installing the Exciters
14
EX3300 Series Exciter Installation & Configuration Guide
Exciter
4.
Re-insert the battery into the dispenser.
5.
Reinstall the soap container back into the dispenser.
6.
Close the dispenser casing.
7.
Test the Exciter and dispenser operation.
Installing the Exciters
15
EX3300 Series Exciter Installation & Configuration Guide
Installing the EX3300 in a GOJO LTX Dispenser
To open the dispenser:
Simultaneously press the two buttons situated on both sides of the
dispenser. This releases the front of the dispenser's outer casing, allowing
it to open forwards.
To install the Exciter:
1.
Remove at least one of the batteries of the dispenser to cut the power to
it.
2.
Snap the Exciter into its customized compartment in the front side of the
dispenser. There may be a need to remove a plastic placeholder from the
compartment. This is done by simply snapping it out.
3.
Plug the Exciter's audio jack cable into the dispenser's connector.
Installing the Exciters
16
EX3300 Series Exciter Installation & Configuration Guide
Audio
jack
Exciter
4.
Insert the battery/s that was removed back into the dispenser.
5.
Insert the soap container back into the dispenser.
6.
Close the dispenser casing.
7.
Test the Exciter and dispenser operation.
Installing the Exciters
17
EX3300 Series Exciter Installation & Configuration Guide
Adding the Exciters to the Engine Manager
Follow these steps:
1.
2.
Do one of the following:
•
In a Cisco-based configuration using MSE 7.4 or below, add Exciters via
the Cisco NCS/PI when, Consult Cisco documentation for further
information
•
In a non Cisco environment or when using Cisco MSE 7.5 or above add
Exciters via AeroScout Engine Manager
Access Engine Manager and perform the following steps for each one of the
Hand Hygiene Exciters:
a.
In the Configuration menu select Advanced Mode.
b.
Double-click on the Exciter icon on the map to access the Exciter
Properties.
c.
In the Exciter Modules dialog box, check the Internal LF Exciter box.
d.
Ensure the Connected to Network check-box is not selected.
e.
Select the Settings tab.
f.
In HW ID, enter the Exciter ID.
The Exciter ID is located on a sticker on the front cover of the Exciter.
The ID can also be read from the Exciter using the Exciter Manager Tool
and the Exciter's serial cable.
Adding the Exciters to the Engine Manager
18
EX3300 Series Exciter Installation & Configuration Guide
Note
If the ID is already in use by another Exciter, and the Exciter is reachable
(not offline), the system automatically switches IDs between the two
Exciters. If the Exciter is unreachable, change the ID manually.
g.
Click OK.
h.
Ensure all dispenser Exciters appear offline on the map
Adding the Exciters to the Engine Manager
19
EX3300 Series Exciter Installation & Configuration Guide
Advanced Configuration
Advanced configuration of the EX3300 Exciter is done via the Exciter Manager.
The Exciter Manager Tool enables configuring the Exciter's maximum
transmission range and Exciter ID.
EX3300 Exciters are configured using a customized serial cable via the Exciter
Manager Tool. The cable is not supplied with the Exciters and must be ordered
separately.
For more instructions on configuring the EX3300 Exciter, please refer to the
Exciter Manager User Guide.
Depending on the dispenser type (Gojo, EcoLab), embedded EX3300 Exciters
require different serial cables.
Figure 3: Customized EX3300 Serial Cable for GoJo TFX Dispensers (SKU: CAB-3300)
Figure 4: Customized EX3300 Serial Cable for EcoLab Dispensers (CAB-3300-CN)
Advanced Configuration
20
EX3300 Series Exciter Installation & Configuration Guide
Figure 5: Customized EX3300 Serial Cable for GOJO LTX and TFX Dispensers (CAB-3300LTX)
Replacing a Malfunctioning Exciter
If an embedded EX3300 Exciter is identified as malfunctioning or damaged it
can be replaced on site by performing the following tasks:
1.
Open the dispenser and remove the EX3300 Exciter.
2.
Using the Exciter serial configuration cable and the Exciter Manager Tool
configure the Exciter ID of the replacement Exciter, with the same ID as
the malfunctioning/damaged Exciter. It is recommended to annotate the
new ID on the Exciter housing for future needs.
3.
Configure the range of the Exciter (if required).
4.
Install the replacement EX3300 Exciter in the Dispenser.
5.
Test the Exciter.
Replacing a Malfunctioning Exciter
21
EX3300 Series Exciter Installation & Configuration Guide
EX3300 Series Exciter Models and Cables
Summary
Vendor
SKU
EX-3300-ELB
Name
EX3300 Hand
Hygiene Exciter for
EcoLab Next Gen
Dispensers
Dispenser Type
Dispenser Image
Next Gen
Part Number
Exciter Image
92021121
eKey
Configuration Cable
N/A
CAB-3300-CN
N/A
CAB-3300-CN
Cable Image
Long Cable
EcoLab
EX-3300-NEXA
EX3300 Hand
Hygiene Exciter for
EcoLab NEXA
Dispensers
NEXA
92021188 (large)
92021184 (small)
Short Cable
GOJO
EX-3300-LTX
EX3300 Hand
Hygiene Exciter for
GOJO LTX Dispensers
LTX
1971-04 (large)
1371-04 (small)
N/A
CAB-3300-LTX
EX-3300-PRL
EX3300 Hand
Hygiene Exciter for
GOJO TFX Purell
Dispensers
TFX
2720-12
Grey
CAB-3300
EX-3300-PRV
EX3300 Hand
Hygiene Exciter for
GOJO TFX Provon
Dispensers
TFX
2745-12
Grey
CAB-3300
EX-3300-PRS
EX3300 Hand
Hygiene Exciter for
GOJO TFX Purell
Surgical Scrub
Dispensers
TFX
2785-12
Orange
CAB-3300
EX-3300-CHG
EX3300 Hand
Hygiene Exciter for
GOJO TFX Provon
with CHG Dispensers
TFX
2845-12
Natural
CAB-3300
EX3300 Series Exciter Models and Cables Summary
22
EX3300 Series Exciter Installation & Configuration Guide
EX3300 Specifications
Physical and Mechanical for the GoJo TFX Exciter (including housing)
•
Dimensions: 80 x 48 mm x 45 mm (3.2 in. x 1.9 in. x 1.8 in.)
•
Weight: 30 g (1.1 oz.)
Physical and Mechanical for the GoJo LTX Exciter (including housing)
•
Dimensions: 80 x 48 mm x 20 mm (3.2 in. x 1.9 in. x 0.8 in.)
•
Weight: 30 g (1.1 oz.)
Physical and Mechanical for the EcoLab Exciters (including housing)
•
Dimensions: 62 x 63 mm x 13 mm (2.4 in. x 2.5 in. x 0.5 in.)
•
Weight: 20 g (0.7 oz.)
Coverage
•
Adjustable coverage range up to 2 m (6.5 ft.) by intervals of 0.25 m (0.8
ft.)
LF Channel
•
125 kHz
•
Field intensity limits: 37.3 dBµA/m at 10 m (ETSI)
•
Propagation limits: 21.8 dBµV/m at 300 m (FCC)
•
Modulation: ASK
Power
•
Use only alkaline batteries as provided by the manufacturer
•
Input voltage range:
•
GoJo 3V – 4.6V
•
Ecolab 3.6V – 4.6V
•
Maximum power consumption: 1 W
•
Maximum current: 6A (including short circuiting and overload)
Environmental
•
Operating temperature: 0 to 50 °C (32°F to 122°F)
•
Humidity: 0 to 95%, non-condensing
EX3300 Specifications
23
EX3300 Series Exciter Installation & Configuration Guide
Certifications
•
•
EMC Certifications
US standard: FCC part 15
European standard: ETSI 300.328, 300.330, ETSI 301.489
Canada: RSS 210 per demand
EMC standard for healthcare: IEC 6100 / EN 60601
Japan : ARIB per demand
Australia : C-tick per demand
Korea : MIC per demand
Safety Certifications
US – cTUVus: UL 60950
Europe – CE mark: EN 60950
EX3300 Specifications
24
WARNING: Insertion of an EX-3300 Exciter into any host other than the EcoLab Hand Sanitizer
Dispenser or the GoJo Hand Sanitizer Dispenser invalidates the FCC ID authorization and
Industry Canada certification of the EX-3300 Exciter.
WARNING: This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and
Science Canada. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnemen.
WARNING: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
residential installations. This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio and television
reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does
cause such interference, which can be verified by turning the device off and on, the user is encouraged to
eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
About STANLEY Healthcare
STANLEY Healthcare provides over 5,000 acute care hospitals and 12,000 long-term care organizations
with enterprise solutions that transform safety, security and operational efficiency. The STANLEY
Healthcare solution set enables customers to achieve organizational excellence and superior care in
five critical areas: Security & Protection, Safety, Environmental Monitoring, Clinical Operations &
Workflow, and Supply Chain & Asset Management. These solutions are complemented by consulting,
training, implementation and integration services. STANLEY Healthcare is proud to be part of Stanley
Black & Decker, Inc. For more information, visit: www.stanleyhealthcare.com
STANLEY Healthcare
130 Turner Street
Building 3
Waltham, MA 02453
Tel: +1-888-622-6992
Asia-Pacific
E-mail: stanleyhealthcare-asiapac@sbdinc.com
North America
E-mail: stanleyhealthcare@sbdinc.com
Middle East
E-mail: stanleyhealthcare-MEA@sbdinc.com
Europe
E-mail: shs-uk@sbdinc.com
Latin America
E-mail: stanleyhealthcare-latam@sbdinc.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : daniel.pearlman@aeroscout.com
Create Date                     : 2015:04:13 15:46:18+03:00
Modify Date                     : 2015:04:13 15:46:22+03:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2015:04:13 15:46:22+03:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:6c850715-ccac-4f0c-b712-8724eee0efde
Instance ID                     : uuid:674b4010-843c-454a-9119-1734e08576df
Subject                         : 4
Format                          : application/pdf
Title                           : EX3300 Series Exciter Installation & Configuration Guide
Creator                         : daniel.pearlman@aeroscout.com
Producer                        : Adobe PDF Library 10.0
Source Modified                 : D:20150413124611
Company                         : Hewlett-Packard
Page Layout                     : OneColumn
Page Count                      : 26
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3HEX3300

Navigation menu