AeroScout EX3300 HAND HYGIENE INTEGRATED EXCITER User Manual Tag Manager Professional Edition

AeroScout HAND HYGIENE INTEGRATED EXCITER Tag Manager Professional Edition

Contents

Users Manual

AeroScout EX3300 Exciters
User’s Guide
EX3300-UG-221111-01
Disclaimer
The information and know-how included in this document are the exclusive property of AeroScout Inc.
and are intended for the use of the addressee or the user alone. The addressees shall not forward to
another their right of using the information, know-how or document forwarded herewith, in whole or
in part in all matters relating or stemming from or involved therein, whether for consideration or
without consideration, and shall not permit any third party to utilize the information, know-how or the
documents forwarded herewith or copies or duplicates thereof, unless at the company’s consent in
advance and in writing. Any distribution, advertisement, copying or duplication in any form
whatsoever is absolutely prohibited. The Company reserves the right to sue the addressee, user
and/or any one on their behalves, as well as third parties, in respect to breaching its rights pertaining
to the intellectual rights in particular and its rights of whatever kind or type in the information, know-
how or the documents forwarded by them herewith in general, whether by act or by omission.
This document is confidential and proprietary to AeroScout Inc. and is not to be distributed to any
persons other than licensed AeroScout Visibility System users or other persons appointed in writing
by AeroScout Inc.
Trademark Acknowledgements
AeroScout™ is a trademark of AeroScout, Inc. Other brand products and service names are
trademarks or registered trademarks of their respective holders. Below is a partial listing of other
trademarks or registered trademarks referenced herein:
Cisco™ is a trademark of Cisco Systems, Inc.
Sun, Sun Microsystems, the Sun Logo, Java, JRE and all other Sun trademarks, logos, product names,
service names, program names and slogans that are referred to or displayed in this document are
trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other
countries.
This product includes software developed by the Apache Software Foundation
(http://www.apache.org/).
This product includes code licensed from RSA Data Security
Esper is a trademark of EsperTech, Inc.
Jboss is a trademark of Red Hat Middleware, LLC.
Oracle 10G and Oracle 11G are registered trademarks of Oracle Corporation and/or its affiliates.
MS SQL Server 2005 and MS SQL Server 2008 are registered trademarks of Microsoft Corporation in
the United States and/or other countries.
JasperSoft, the JasperSoft Logo, JasperReports, the JasperReports logo, JasperIntelligence,
JasperDecisions, JasperAnalysis, Scope Center, Scope Designer, and JasperServer are trademarks or
registered trademarks of JasperSoft, Inc. in the United States and other countries.
Images of PLUM A+™, PLUM A+™ 3, LIFECARE PCA™, and SYMBIQ™ infusion systems are provided
with permission of Hospira, Inc. All rights reserved.
Copyright ©2011 AeroScout Inc. All rights reserved.
AeroScout EX3300Exciter
Table of Contents 3
Table of Contents
Introduction ......................................................................................................................... 6
EX3300 Features .................................................................................................................. 7
EX3300 Models .................................................................................................................... 8
Mounting the Exciter ......................................................................................................... 8
Adding the Exciters to the AeroScout Engine ................................................................ 9
Advanced Configuration ................................................................................................. 10
EX3300 Model Numbers .................................................................................................. 12
EX3300 Specifications ....................................................................................................... 13
AeroScout EX3300Exciter
Table of Figures 4
Table of Figures
Figure 1: Embedded EX3300 triggering a staff tag ............................................................ 6
Figure 2: Entering an Exciter ID in System Manager ...................................................... 10
Figure 3: Customized EX3300 Serial Cable....................................................................... 11
AeroScout EX3300Exciter
Document History 5
REVISION HISTORY
Revision
Date
Comments
Author
1
22 November 2011
New document
Refael Blanca
Introduction
The AeroScout EX3300 Exciters series are key components of the AeroScout Hand
Hygiene Solution. The EX3300 Exciters provide robust and sophisticated RFID
detection capabilities, using the same AeroScout tags that can also be accurately
located in real time by the AeroScout system.
The EX3300 Exciters are specialty designed to be embedded in Hand Hygiene
dispenser. When a dispenser with an embedded EX3300 Exciter is activated, the
Exciters trigger AeroScout’s tags that are located near the Exciter and the tags in turn
transmit a message to AeroScout Location Receivers or compatible Access Points in
range. This provides instant acknowledgment that a tagged staff member has used
the dispenser. The AeroScout Visibility System can detect, record and report the rate
of usage of the dispensers per user and provides a revolutionary way for health care
facilities to monitor the hand hygiene policy compliance of staff members.
Figure 1: Embedded EX3300 triggering a staff tag
EX3300 Features
Hand Hygiene Dispenser Integration
EX3300 Exciters are specially designed to be embedded in GOJO and Ecolab hand
hygiene dispensers. The embedded exciter reacts to a dispenser activation and
triggers all tags in range to transmit a message to a nearby access point.
RFID detection of AeroScout Tags
Triggering the tags to transmit as they enter a defined area, EX3300s reach up to a 6
meter (19.6ft) range, enough to cover typical door or gate areas.
Note
Tag behavior modification:
The EX3300 can wirelessly active and deactivate tags. Tag battery life can be
extended further by switching the tags off when they leave a defined tracking area
through a gate or doorway.
It is also possible to configure the Exciter to change of tag transmission rate
temporarily or indefinitely to accommodate different usage patterns in various
physical spaces.
Message Programming functions
The EX3300 has the ability to store messages on the tag for later transmission.
Message transmission can later be triggered by other EX3300s, enabling
sophisticated process control functions.
EX3300 can trigger a tag to:
Transmit up to 15 bytes of data sent to it by the EX5100;
Transmit one of 15 pre-stored messages;
Transmit and store up to 15 bytes of data sent to it by the EX5100.
EX3300 Models
The AeroScout EX3300 is an offline exciter designed to integrate with the following
dispenser models:
Order Number
TFX Touch Free
Dispensers
EX-3300-PRL
PURELL TFX Touch Free
Dispenser
EX-3300-ELB
EcoLab Touch-Free
Dispenser
Mounting the Exciter
Follow these steps to install an EX3300 in a Hand Hygiene dispenser:
1. Open the dispenser by
2.
Note
the EX-3300 Exciter may not be inserted into any host units other than the ECOLAB
Hand Sanitizer Dispenser or the GOJO Hand Sanitizer Dispenser.
Adding the Exciters to the AeroScout Engine
Follow these steps:
1. Do one of the following:
In a Cisco-based configuration, add the Exciters via WCS.
If you are using AeroScout Standalone Engine, add the Exciter via System
Manager.
2. Access System Manager and perform the following steps for each one of the
Hand Hygiene Exciters:
a. In the Configuration menu select Advanced Mode.
b. Access the Exciter properties by double-clicking the Exciter's icon.
c. In the Exciter Modules window click on Internal LF Exciter and select the
Settings tab.
d. In HW ID, enter the Exciter ID. See Figure 2.
Note
e. Click OK.
Figure 2: Entering an Exciter ID in System Manager
f. Make sure all dispenser Exciters appear offline on the map
Advanced Configuration
Advanced configuration an EX3300 Exciter is done via the AeroScout Exciter
Manager. The Exciter Manager enables configuring the Exciter's Maximum
Transmission Range, Exciter ID, and IP address.
The EX3300 Exciters are equipped with a customized serial cable used to configure
the Exciter via the Exciter manager.
For more instructions on configuration the EX3300, please refer to the AeroScout
Exciter Manager User Guide.
Figure 3: Customized EX3300 Serial Cable
EX3300 Family SKUs
Product Name
SKU
Description
EX3300
Integrated Exciter
EX-3300
Includes Exciter board (no housing) for embedding into
devices. Doesn't include the integration connector on the
board.
EX3300
Integrated Exciter
with Connector
EX-3300-CN
Includes Exciter board (no housing) for embedding into
devices. The integration connector is assembled on the
board
EX3300PRL Hand
Hygiene Exciter
EX-3300-PRL
EX3300 Integrated Exciter for Purell TFX SmartLink
Dispenser. Exciter is shipped embedded inside a
complete dispenser. Should be ordered only in the case
of deployments that require new dispensers. (e.g.
facilities without dispensers or those that are replacing
manual dispensers)
EX3300PRV Hand
Hygiene Exciter
EX-3300-
PRV
EX3300 Integrated Exciter for Provon TFX SmartLink
Dispenser. Exciter is shipped embedded inside a
complete dispenser. Should be ordered only in the case
of deployments that require new dispensers. (e.g.
facilities without dispensers or those that are replacing
manual dispensers)
EX3300PRS Hand
Hygiene Exciter
EX-3300-
PRS
EX3300 Integrated Exciter for Purell Surgical Scrub TFX
SmartLink Dispenser. Exciter is shipped embedded
inside a complete dispenser. Should be ordered only in
the case of deployments that require new dispensers.
(e.g. facilities without dispensers or those that are
replacing manual dispensers)
EX3300ELB Hand
Hygiene Exciter
EX-3300-
ELB
EX3300 Integrated Exciter for EcoLab Touch-Free
Dispenser. Exciter is shipped embedded inside the
dispenser.
EX3300PRL Hand
Hygiene Exciter
for Dispenser
Retrofit
EX-3300-
PRL-RT
EX3300 Integrated Exciter for Purell TFX SmartLink
Dispenser. Exciter is shipped with a pump house to
retrofit an existing dispenser.
EX3300PRV Hand
Hygiene Exciter
for Dispenser
Retrofit
EX-3300-
PRV-RT
EX3300 Integrated Exciter for Provon TFX SmartLink
Dispenser. Exciter is shipped with a pump house to
retrofit an existing dispenser.
EX3300PRS Hand
Hygiene Exciter
for Dispenser
Retrofit
EX-3300-
PRS-RT
EX3300 Integrated Exciter for Purell Surgical Scrub TFX
SmartLink Dispenser. Exciter is shipped with a pump
house to retrofit an existing dispenser.
EX3300 Specifications
Physical and Mechanical (with the housing)
Dimensions: 74 x 50 x 44 mm (2.9in x 1.97in x 1.8in)
Weight: 32g (1.13oz)
Coverage
Adjustable coverage range up to 2m (6.6ft) by intervals of 0.25m (0.83ft)
LF Channel
125kHz
Field intensity limits: 37.3dBµA/m at 10m (ETSI)
Propagation limits: 21.8dBµV/m at 300m (FCC)
Modulation: ASK
Power
Input voltage:
GOJO 4.5V
Ecolab 6V
Maximum power consumption: 2W
Environmental
Operating temperature: 0 to 50 °C (32°F to 122°F)
Humidity: 0 to 95%, non-condensing
Certifications
EMC Certifications
o US standard: FCC part 15
o European standard: ETSI 300.328, 300.330, ETSI 301.489
o Canada: RSS 210
o EMC standard for healthcare: IEC 6100 / EN 60601
o Japan : ARIB per demand
o Australia : C-tick per demand
o Korea : MIC per demand
Safety Certifications
o US cTUVus: UL 60950
o Europe CE mark: EN 60950
WARNING: Insertion of an EX-3300 Exciter into any host other than the
ECOLAB Hand Sanitizer Dispenser or the GOJO Hand Sanitizer Dispenser
invalidates the FCC ID authorization and Industry Canada certification of
the EX-3300 Exciter.
WARNING: This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and
Science Canada. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
FCC STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
d) Consult the dealer or an experienced radio/TV technician.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
a) This device may not cause harmful interference
b) This device must accept any interference received, including interference that may
cause undesired operation.
FCC Warning
Modifications not expressly approved by the manufacturer could void the user authority
to operate the equipment under FCC Rules.
About AeroScout
AeroScout is the market leader in Unified Asset Visibility solutions. Clients improve operational
efficiency and quality using AeroScout products that leverage standard Wi-Fi networks to track and
manage the location, condition and status of mobile assets and people. AeroScout’s global customer
base consists of leading hospital, manufacturing and logistics organizations, including many of the
Fortune 500. The company originally invented the first Wi-Fi-based Active RFID tag, and today is
widely recognized as leading the market in number of deployments and tags shipped. Headquartered
in Redwood City, Calif., AeroScout has offices in Europe, Asia, the Middle East, Latin America and
Australia. For more information, please visit www.aeroscout.com.
AeroScout (Headquarters)
1300 Island Drive
Suite 202
Redwood City, CA 94065
Tel: +1 (650) 596-2994
Fax: +1 (650) 596-2969
E-mail: info@aeroscout.com
Europe, Middle East, Africa Office
Tel : +32 2 709 29 49
Fax : +32 15 30 80 99
E-mail: emea@aeroscout.com
Japan Office
Tel: +81 3 3556 9003
Fax: + 81 3 5875 3723
E-mail: info@aeroscout.co.jp
Latin America Office
Tel : +52 55 5001 5769
E-mail: latam@aeroscout.com
Asia-Pacific Sales
Tel : +1 650 596 2994
E-mail: apac@aeroscout.com
Australia and New Zealand Sales
Tel : +61 3 9038 8690
E-mail: anz@aeroscout.com

Navigation menu