Agilent Technologies 8590 Users Manual
8590 to the manual 8f8689e8-c17a-416b-b190-deb862ff3815
2015-02-02
: Agilent-Technologies Agilent-Technologies-8590-Users-Manual-413142 agilent-technologies-8590-users-manual-413142 agilent-technologies pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Agilent 8590 C/E/L/Q and EM Series Spectrum Analyzers and Accessories Configuration Guide 8591C Cable TV Analyzer (1 MHz to 1.8 GHz) 8591E RF Spectrum Analyzer (9 kHz to 1.8 GHz) 8593E Microwave Spectrum Analyzer (9 kHz to 22 GHz) 8594E RF Spectrum Analyzer (9 kHz to 2.9 GHz) 8595E RF Spectrum Analyzer (9 kHz to 6.5 GHz) 8596E Microwave Spectrum Analyzer (9 kHz to 12.8 GHz) 8590L Spectrum Analyzer (9 kHz to 1.8 GHz) 8592L Microwave Spectrum Analyzer (9 kHz to 22 GHz) 8594L RF Spectrum Analyzer (9 kHz to 2.9 GHz) 8594Q QAM Analyzer (9 kHz to 2.9 GHz) 8591EM EMC Analyzer (9 kHz to 1.8 GHz) 8593EM EMC Analyzer (9 kHz to 22 GHz) 8594EM EMC Analyzer (9 kHz to 2.9 GHz) 8595EM EMC Analyzer (9 kHz to 6.5 GHz) 8596EM EMC Analyzer (9 kHz to 12.8 GHz) 2 Memory card reader Precision frequency reference Local oscillator and sweep + tune outputs (rear panel) Built-in tracking generator, 50 Ohm (100 kHz–1.8 GHz) Built-in tracking generator, 50 Ohm (9 kHz–2.9 GHz) Built-in tracking generator, 75 Ohm (100 kHz–1.8 GHz) DECT source Protective soft tan carrying/operating case Protective soft yellow operating/carrying case Frequency extension to 26.5 GHz (APC 3.5 mm connector) Frequency extension to 26.5 GHz (type-N connector) Adds 85921B Cable TV Data Management S/W for FCC Front panel protective cover w/CRT viewing hood GPIB interface and parallel printer interface 4, 22 Protective soft carrying case/backpack 21 RS-232 interface and parallel printer interface 4, 22 Improved amplitude accuracy for NADC-TDMA/PCS bands Improved amplitude accuracy for PDC bands Improved amplitude accuracy for PHS band Improved amplitude accuracy for CDMA/PCS bands Adds 85878A report generation software Delete manual set Fast time-domain sweeps and Analog + display AM/FM demod. with speaker and TV sync. trigger 5, 24 Quasi-peak detector and AM/FM demod with speaker 24 Time-gated spectrum analysis TV receiver video tester32 CT2 demodulator Group delay w/compatible tracking generator34 DECT demodulator24 Noise figure7 Narrow resolution bandwidths (30 Hz,100 Hz,300 Hz and 200 Hz EMI) Narrow resolution bandwidths/precision frequency reference (Opt 004 and 130) DSP, fast ADC, and digital demodulator29 PDC, PHS, NADC, and CDMA firmware for Option 15135 o 003 o 004 o 009 o 010 o 010 o 011 o 012 o 015 o 016 o 026 o 027 o 030 o 040 o 041 o 042 o 043 o 050 o 051 o 052 o 053 o 078 o 0B0 o 101 o 102 o 103 o 105 o 107 o 110 o 111 o 112 o 119 o 130 o 140 o 151 o 160 6, 24 75 Ohm input impedance o 001 31 Description Option 0 2 1 1 1 1 2 1 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 128 0 128 0 0 0 Opt Card Slots Req’d (4 max) ü ü ü Std Std ü Std ü ü Std ü ü Std Std Std 8591C ü25 ü25 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std 8593E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü 8591E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std 8594E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std 8595E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std 8596E ü ü ü ü ü ü ü ü ü ü ü 8590L ü = compatible ü ü ü ü ü ü ü ü ü ü 8592L ü ü ü ü ü ü ü ü 8594L ü ü Std ü ü ü Std Std 8594Q Std Note 3 ü ü ü ü ü Std ü2 ü2 ü ü ü ü ü14 ü Std 8590EM Series Agilent 8590 C/E/L/Q and EM Series Options TV picture on screen (NTSC, PAL, and SECAM)32 DVB-C RF and modulation quality measurements R-S and true BER and PID statistics data measurements TV sync. trigger capability, fast time domain sweeps, AM/FM demodulator, and Analog + display (Option 101 and 102)24 2 Delete TV sync. trigger capability, fast time domain sweeps, AM/FM demodulator and Analog + display (Options 101 and 102) Delete quasi-peak detector and AM/FM demodulator Delete precision frequency reference 50/75 Ohm matching pad with 100V DC block Rack mount kit without handles Rack mount kit with handles Additional user's guide, calibration guide, and quick reference guide Component level information and service guide Quick reference guide in local languages8 DRTS compatibility PAL/SECAM TV monitor 23 NTSC TV monitor Refurbished spectrum analyzer (as available) Factory service training Commercial calibration certificate with test data Two additional years return-to-Agilent service 9 Two additional years return-to-Agilent calibration 9 3 year standards compliant calibration service Four additional years return-to-Agilent service 9 Four additional years return-to-Agilent calibration 5 year standards compliant calibration service BenchLink spectrum analyzer Code division multiple access Global system for mobile communication North American digital cellular system Pacific digital cellular system Personal handyphone system o 180 o 190 o 195 o 301 o 701 o 703 o 704 o 711 o 908 o 909 o 910 o 915 o AB_ o E04 o H80 o H81 o 8ZE o 0Q8 o UK6 o W30 o W32 o W34 o W50 o W52 o W54 o B70 o BD0 o BD1 o BD2 o BD3 o BD4 9 GSM900/DCS1800 firmware for Option 15135 o 163 2 2 2 2 2 0 0 0 2 0 0 –1 –2 1 3 1 0 Description Option Opt Card Slots Req’d (4 max) ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8591E ü ü ü ü ü ü18 ü ü ü ü ü ü Std ü 8591C ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8593E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8594E ü ü ü ü ü ü ü ü ü 8596E ü ü ü ü ü ü ü 8590L ü ü ü ü ü ü ü 8592L ü ü ü ü ü 8594L ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Contact an Agilent representative for availability Note 1 ü ü ü ü ü ü ü ü ü 8595E ü = compatible ü ü ü ü ü ü ü ü ü ü ü ü 8594Q ü ü ü ü ü ü ü ü ü ü ü ü 8590EM Series Agilent 8590 C/E/L/Q and EM Series Options (continued) 3 4 Memory card reader Precision frequency reference CT2 demodulator 6, 24 DECT demodulator 24 TV receiver/video tester1 Built-in tracking generator, 50 Ohm (100 kHz to 1.8 GHz) Built-in tracking generator, 50 Ohm (9 kHz to 2.9 GHz)17 Built-in tracking generator, 75 Ohm (100 kHz to 1.8 GHz) Time-gated spectrum analysis Protective soft yellow operating/carrying case Noise figure 7 GPIB interface 4, 22, 27 RS-232 interface 4, 22, 27 Parallel printer interface 22, 27 Protective soft tan operating/carrying case Narrow resolution bandwidths GPIB interface and parallel printer interface 4, 22, 26 RS-232 interface and parallel printer interface 4, 22, 26 Improved amplitude accuracy for NADC-TDMA/PCS bands Improved amplitude accuracy for PDC bands Improved amplitude accuracy for PHS band Improved amplitude accuracy for CDMA/PCS cellular bands PDC, PHS, NADC, and CDMA firmware for Option 15135 GSM900/DCS1800 firmware for Option 151 PDC/PHS/NADC/CDMA FW+Opt 151 retro. kit 35 DSP, fast ADC, and digital demodulator with GSM900/DCS1800 firmware 35 TV picture on screen (NTSC, PAL, and SECAM) R-S and true BER and PID statistics data measurements Group delay retrofit kit Quasi-peak detector and AM/FM demod retrofit kit o R03 o R04 o R05 o R06 o R07/R17 o R10 o K10 o R11 o R15 o R16 o R19 o R21 o R23 o R24 o R25 o R30 o R41 o R43 o R50 o R51 o R52 o R53 o R60 o R63 o R70 o R73 o R80 o R95 o 11768A o 11946A 35 Fast time-domain sweeps and analog + display AM/FM demodulator with speaker and TV sync trigger circuitry 5 o R01 o R02 Description Option 1 1 1 1 2 2 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 1 0 1 1 1 0 0 1 1 Opt Card Slots Req’d (4 max) ü Std ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8591C ü ü ü25 ü25 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8591E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8594E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8593E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8595E ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Std ü ü 8596E ü ü ü ü ü ü ü ü ü ü 8590L ü = compatible ü ü ü ü ü ü ü ü 8592L ü ü ü ü ü ü 8594L Std Std Std 8594Q Std 8590EM Series Agilent 8590 C/E/L/Q and EM Series Retrofit Kits 10 (for option installation after analyzer purchase) 128 Kbyte blank memory card (RAM)11 256 Kbyte blank memory card (RAM)11 512 Kbyte blank memory card (RAM)11 Link measurements personality EMC measurements personality 12 Digital radio measurements personality 11 Scalar measurements personality 11 GSM900 measurements personality with modulation accuracy19 CT2-CAI measurements personality NADC/PCS -TDMA measurements personality19 Noise figure measurements personality PDC measurements personality upgrade kit: B to C PDC measurements personality with modulation accuracy19 Cable TV measurements personality with video tests11,18,15 DCS1800 measurements personality with modulation accuracy DECT measurements personality Broadcast measurements personality CDMA measurements personality CDMA measurements personality upgrade kit: B to C PHS measurements personality upgrade kit: A to B PHS measurements personality with modulation accuracy GSM Multi-band measurement personality GSM Multi-band upgrade o 85702A o 85704A o 85705A o 11770A o 85712D o 85713A o 85714A o 85715B o 85717A o 85718B o 85719A o 85720BC o 85720C o 85721A o 85722B o 85723A o 85724A o 85725C o 85725CU o 85726AB o 85726B o 85727A o 85727AU Cable TV data management S/W for FCC 31 Benchlink spectrum analyzer o 85921B o E4444A PC Software 32 Kbyte blank memory card (RAM)11 o 85700A 30 Description Option ü ü ü Std ü ü ü ü ü ü 8591C ü ü33 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8591E ü ü ü ü33 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü33 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8594E ü ü ü ü 8593E ü = compatible ü ü33 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8595E ü ü33 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8596E ü ü33 ü ü ü ü ü ü 8590L ü ü33 ü ü ü ü ü ü 8592L ü ü33 ü ü ü ü ü 8594L ü ü ü ü ü 8594Q ü ü ü ü ü 8590EM Series Agilent 8590 C/E/L/Q and EM Series Measurement Personalities 13 5 Agilent 8590 C/E/L/Q and EM Series Accessories For Scalar Measurements o 85630A Scalar 50 Ohm transmission/reflection test set o 86205A 50 Ohm RF bridge (type-N(f), 300 kHz to 6 GHz, 1.5 dB +0.1 dB/GHz insertion loss) o 86207A 75 Ohm RF bridge (type-N(f), 300 kHz to 3 GHz, 1.5 dB +0.1 dB/GHz insertion loss) For EMC Measurements o 11945A Close field probe set (9 kHz to 1 GHz) (with Option E51)16 o 11947A Transient limiter (BNC(f) to type-N(m), 9 kHz to 200 MHz, 10 dB insertion loss) Printers and Accessories o 11867A RF Limiter (type-N(f) to type-N(m), DC to 1.8 GHz, <.75 dB insertion loss) o 11930B Power limiter (5 MHz to 6 GHz) o 41800A Active probe (5 Hz to 500 MHz) o 85024A High frequency probe (300 kHz to 3 GHz) o 85901A Portable AC power source o 85902A Burst carrier trigger o 1420-0383 Memory card battery (CR 2016) o 1494-0060 Rack slide for rack mount o 08590-60369 RS-232/parallel connector assembly to convert Opt. 041 (GPIB) to Opt. 043 (RS-232) o 08590-60368 GPIB/parallel connector assembly to convert Opt. 043 (RS-232) to Opt. 041 (GPIB) Most Hewlett-Packard DeskJet and LaserJet (PCL 3 compatible) printers are compatible with 8590 series spectrum analyzers. Printer compatibility chart is on the internet web site at www.agilent/com/find/pcg/ o 9211-5604 Transit case o 10833A GPIB cable (1 meter) o 5062-4841 o 24542U RS-232 cable 3 meter (9 pin F to 9 pin F) Option 043 only (for RS-232 9 pin PC connection to analyzer) Rack mount without handles20 (centers instrument in rack) o 5062-4840 Rack mount with handles20 (centers instrument in rack) o 5062-8240 Rack mount with handles 20 (mounts instrument left of center) o 5062-8241 Rack mount without handles 20 (mounts instrument left of center) o 24542G RS-232 cable 3 meter (25 pin M to 9 pin F) Option 043 only (for RS-232 25 pin PC or printer connection to analyzer) o 24542M RS-232 cable 3 meter (25 pin M to 9 pin F) Option 043 only (for RS-232 25 pin modem connection to analyzer) o C2932A RS-232 cable 3 meter (9 pin M to 9 pin F) Option 043 only (for serial 9 pin LaserJet 4P/4Plus connection to analyzer) o 13242G RS-232 cable (5 meter) (for Option 023 only) o 08590-90234 8590 E/L Series user's guide o C2950A Parallel printer cable (2 meter) o 08590-90243 8590 E/L Series quick reference guide o ITEL-45CHVUB GPIB/Parallel converter (North America, Japan, Korea, and Taiwan) o ITEL-45CHVEB GPIB/Parallel converter (Continental Europe, U.K., Australia, and South Africa) (requires F1011A AC adapter) Amplifiers and Preamplifiers o 5180-9055 CRT viewing hood (sun shield) o 5063-0654 Frequency accuracy retrofit kit for 8590B and 8590D Agilent 8590 C/E/L/Q-Series Manuals o 08590-90235 8590 Series programmer's guide o 5960-6588 8590 E/L Series quick reference guide in French o 5960-6590 8590 E/L Series quick reference guide in German o 5960-6592 8590 E/L Series quick reference guide in Italian o 5960-6594 8590 E/L Series quick reference guide in Spanish o 8447D Preamplifier (100 kHz to 1.3 GHz, >25 dB gain) o 5960-6596 8590 E/L Series quick reference guide in Japanese o 8449B Preamplifier (1 GHz to 26.5 GHz, 30 dB gain) o 08590-90260 8590 E/L Series user’s guide for Taiwan in Chinese o 10855A Broadband preamplifier (2 MHz to 1300 MHz, 22 dB gain) o 08590-90261 8590 E/L Series user’s guide for China in Chinese o 85905A 75 Ohm preamplifier (45 MHz to 1GHz, 20 dB gain) o 5962-5001 8590 E/L Series user’s guide in French o 87405A Amplifier (10 MHz to 3 GHz, 22 dB gain) o 5962-5002 8590 E/L Series user’s guide in German o 87415A Amplifier (2 GHz to 8 GHz, 25 dB gain) o 08590-90286 8590 E/L Series user’s guide in Italian o 5962-5004 8590 E/L Series user’s guide in Spanish Other Accessories o D4950A Keyboard o 08590-90269 8590L calibration guide o 346B Noise source (BNC(f) to APC 3.5(m), 10 MHz to 18 GHz) o 08594-90183 859x C/E Series calibration guide o 11693A Limiter (type-N(f) to type-N(m), 0.1 GHz to 12.4 GHz, <2.0 dB insertion loss) o 08592-90082 8592L calibration guide o 5963-2950 8590 C/E/L/Q Series assembly level repair guide o 11694A 75/50 Ohm matching transformer (BNC(f) to BNC(m), 3 MHz-500 MHz, <.75 dB insertion loss) o 5963-2951 8590 C/E/L/Q Series component level repair guide o 08591-90129 8591C Cable TV analyzer user's guide, spectrum analyzer reference o 0955-1020 50 to 75 Ohm adapter. Same as Opt. 711 o 11742A High frequency blocking capacitor (3.5mm(f to m)), 10 MHz to 26.5 GHz, .35 dB IL <12.4 GHz, .7 dB IL <26.5 GHz) o 08591-90176 8591C Cable TV analyzer user’s guide, cable TV measurements o 11852B Order with Option C04, 75/50 Ohm min. loss pad (typeN(f) to type-N(m), DC to 2 GHz, 5.7 dB insertion loss) o 08591-90130 8591C getting started and quick reference guide 6 Agilent 8590 C/E/L/Q and EM Series Notes 1. For more information please contact your local Agilent sales representative. 2. 8593 EM only 3. Quasi-peak detection and AM/FM demodulator is standard on 8590 EM-series and has additional capacity compared to Option 103. 4. Programming manual included 5. Options 101 and 102 required for TV sync trigger capability. See Option 301. 6. 85717A measurement personality required 7. 85719A measurement personality required 8. ABF Quick reference and user’s guides in French ABD Quick reference and user’s guides in German ABZ Quick reference and user’s guides in Italian ABE Quick reference and user’s guides in Spanish ABJ Quick reference guide in Japanese AB0 Quick reference guide for Taiwan in Chinese AB2 Quick reference guide for China in Chinese 9. An incremental cost will be added to the base price of Options W30/W32/W34/W50/W52/W54 for an 859xC/E/L/Q containing Options 010, 011, or 130. 10. Parts only kits. No installation included. May require new analyzer firmware. 11. Option 003 (card reader) on the 8590L, 8592L and 8594L is required. 12. For more information on EMC products and configurations see lit. number 5964-6089E. 13. Refer to measurement personality product literature for required 8590 series option configuration. 14. Except 8591 EM 15. Video tests not supported on 8590L, 8592L or 8594L. 16. Option E51 comes with preamplifier, carrying case, cables and connectors. 17. Tracking generator retrofit requires factory installation of Option K10. 18. Cable TV measurements are formatted for local country's cable TV standards. 19. Modulation accuracy measurements not supported on 8591E. 20. Rack height is 8.75 inches. 21. Not for analyzer operation while in carrying case 22. Options 021, 023 and 024 or 041 and 043 cannot be combined. 23. Not compatible with Option 107 24. Not compatible with other demodulator options (102, 103, 110, 112, or 301). 25. Compatibility with 8591E limited to CDMA applications only 26. Compatible with serial prefixes 3523A or 3525U and higher 27. Compatible with serial prefixes lower than 3523A or 3525U 28. If Options 009 and 010 are combined on the 8593E/94E/95E/96E or 8590 EM series; only one option card slot is required. 29. Not compatible with Options 101 and 301 30. Requires Option 111. Not compatible with 8591E. 31. NTSC Cable TV analyzers only 32. Option 107 is not compatible with Option 180. 33. 85721 Cable TV measurement personality required 34. 11770A Link measurements personality required. Do not order Option 010 with Option 111. 35. Option 160 and 163 are not compatible. 7 Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.” Our Promise “Our Promise” means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage “Your Advantage” means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, outof-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test and measurement needs. Online Assistance www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 452 4844 Canada: (tel) 1 877 894 4414 (fax) (905) 206 4120 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Australia: (tel) 1 800 629 485 (fax) (61 3) 9272 0749 New Zealand: (tel) 0 800 738 378 (fax) (64 4) 495 8950 Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Product specifications and descriptions in this document subject to change without notice. Copyright © 1998, 2000 Agilent Technologies Printed in U.S.A. 7/00 5963-6858E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 8 Create Date : 1910:00:62 11:12:70 Producer : Acrobat Distiller Daemon 3.0 for HP-UX A.09.01 and later (HPPA)EXIF Metadata provided by EXIF.tools