Agilent Technologies 8590 Users Manual

8590 to the manual 8f8689e8-c17a-416b-b190-deb862ff3815

2015-02-02

: Agilent-Technologies Agilent-Technologies-8590-Users-Manual-413142 agilent-technologies-8590-users-manual-413142 agilent-technologies pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadAgilent-Technologies Agilent-Technologies-8590-Users-Manual-  Agilent-technologies-8590-users-manual
Open PDF In BrowserView PDF
Agilent 8590 C/E/L/Q and EM
Series
Spectrum Analyzers and
Accessories
Configuration Guide

8591C Cable TV Analyzer (1 MHz to 1.8 GHz)
8591E RF Spectrum Analyzer (9 kHz to 1.8 GHz)
8593E Microwave Spectrum Analyzer (9 kHz to 22 GHz)
8594E RF Spectrum Analyzer (9 kHz to 2.9 GHz)
8595E RF Spectrum Analyzer (9 kHz to 6.5 GHz)
8596E Microwave Spectrum Analyzer (9 kHz to 12.8 GHz)
8590L Spectrum Analyzer (9 kHz to 1.8 GHz)
8592L Microwave Spectrum Analyzer (9 kHz to 22 GHz)

8594L RF Spectrum Analyzer (9 kHz to 2.9 GHz)
8594Q QAM Analyzer (9 kHz to 2.9 GHz)
8591EM EMC Analyzer (9 kHz to 1.8 GHz)
8593EM EMC Analyzer (9 kHz to 22 GHz)
8594EM EMC Analyzer (9 kHz to 2.9 GHz)
8595EM EMC Analyzer (9 kHz to 6.5 GHz)
8596EM EMC Analyzer (9 kHz to 12.8 GHz)

2

Memory card reader

Precision frequency reference

Local oscillator and sweep + tune outputs (rear panel)

Built-in tracking generator, 50 Ohm (100 kHz–1.8 GHz)

Built-in tracking generator, 50 Ohm (9 kHz–2.9 GHz)

Built-in tracking generator, 75 Ohm (100 kHz–1.8 GHz)

DECT source

Protective soft tan carrying/operating case

Protective soft yellow operating/carrying case

Frequency extension to 26.5 GHz (APC 3.5 mm connector)

Frequency extension to 26.5 GHz (type-N connector)

Adds 85921B Cable TV Data Management S/W for FCC

Front panel protective cover w/CRT viewing hood

GPIB interface and parallel printer interface 4, 22

Protective soft carrying case/backpack 21

RS-232 interface and parallel printer interface 4, 22

Improved amplitude accuracy for NADC-TDMA/PCS bands

Improved amplitude accuracy for PDC bands

Improved amplitude accuracy for PHS band

Improved amplitude accuracy for CDMA/PCS bands

Adds 85878A report generation software

Delete manual set

Fast time-domain sweeps and Analog + display

AM/FM demod. with speaker and TV sync. trigger 5, 24

Quasi-peak detector and AM/FM demod with speaker 24

Time-gated spectrum analysis

TV receiver video tester32

CT2 demodulator

Group delay w/compatible tracking generator34

DECT demodulator24

Noise figure7

Narrow resolution bandwidths (30 Hz,100 Hz,300 Hz
and 200 Hz EMI)

Narrow resolution bandwidths/precision frequency
reference (Opt 004 and 130)

DSP, fast ADC, and digital demodulator29

PDC, PHS, NADC, and CDMA firmware for Option 15135

o 003

o 004

o 009

o 010

o 010

o 011

o 012

o 015

o 016

o 026

o 027

o 030

o 040

o 041

o 042

o 043

o 050

o 051

o 052

o 053

o 078

o 0B0

o 101

o 102

o 103

o 105

o 107

o 110

o 111

o 112

o 119

o 130

o 140

o 151

o 160

6, 24

75 Ohm input impedance

o 001

31

Description

Option

0

2

1

1

1

1

2

1

1

0

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

2

0

128

0

128

0

0

0

Opt Card
Slots Req’d
(4 max)

ü

ü

ü

Std

Std

ü

Std

ü

ü

Std

ü

ü

Std

Std

Std

8591C

ü25

ü25

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

8593E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

8591E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

8594E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

8595E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

8596E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8590L

ü = compatible

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8592L

ü

ü

ü

ü

ü

ü

ü

ü

8594L

ü

ü

Std

ü

ü

ü

Std

Std

8594Q

Std

Note 3

ü

ü

ü

ü

ü

Std

ü2

ü2

ü

ü

ü

ü

ü14

ü

Std

8590EM
Series

Agilent 8590 C/E/L/Q and EM Series Options

TV picture on screen (NTSC, PAL, and SECAM)32

DVB-C RF and modulation quality measurements

R-S and true BER and PID statistics data measurements

TV sync. trigger capability, fast time domain sweeps, AM/FM
demodulator, and Analog + display (Option 101 and 102)24
2

Delete TV sync. trigger capability, fast time domain
sweeps, AM/FM demodulator and Analog + display
(Options 101 and 102)

Delete quasi-peak detector and AM/FM demodulator

Delete precision frequency reference

50/75 Ohm matching pad with 100V DC block

Rack mount kit without handles

Rack mount kit with handles

Additional user's guide, calibration guide,
and quick reference guide

Component level information and service guide

Quick reference guide in local languages8

DRTS compatibility

PAL/SECAM TV monitor 23

NTSC TV monitor

Refurbished spectrum analyzer (as available)

Factory service training

Commercial calibration certificate with test data

Two additional years return-to-Agilent service 9

Two additional years return-to-Agilent calibration 9

3 year standards compliant calibration service

Four additional years return-to-Agilent service 9

Four additional years return-to-Agilent calibration

5 year standards compliant calibration service

BenchLink spectrum analyzer

Code division multiple access

Global system for mobile communication

North American digital cellular system

Pacific digital cellular system

Personal handyphone system

o 180

o 190

o 195

o 301

o 701

o 703

o 704

o 711

o 908

o 909

o 910

o 915

o AB_

o E04

o H80

o H81

o 8ZE

o 0Q8

o UK6

o W30

o W32

o W34

o W50

o W52

o W54

o B70

o BD0

o BD1

o BD2

o BD3

o BD4

9

GSM900/DCS1800 firmware for Option 15135

o 163

2

2

2

2

2

0

0

0

2

0

0

–1

–2

1

3

1

0

Description

Option

Opt Card
Slots Req’d
(4 max)

ü

ü

ü
ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8591E

ü

ü

ü

ü

ü

ü18

ü

ü

ü

ü

ü

ü

Std

ü

8591C

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8593E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8594E

ü

ü

ü

ü

ü

ü

ü

ü

ü

8596E

ü

ü

ü

ü

ü

ü

ü

8590L

ü

ü

ü

ü

ü

ü

ü

8592L

ü

ü

ü

ü

ü

8594L

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Contact an Agilent representative for availability

Note 1

ü

ü

ü

ü

ü

ü

ü

ü

ü

8595E

ü = compatible

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8594Q

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8590EM
Series

Agilent 8590 C/E/L/Q and EM Series Options (continued)

3

4

Memory card reader

Precision frequency reference

CT2 demodulator 6, 24

DECT demodulator 24

TV receiver/video tester1

Built-in tracking generator, 50 Ohm (100 kHz to 1.8 GHz)

Built-in tracking generator, 50 Ohm (9 kHz to 2.9 GHz)17

Built-in tracking generator, 75 Ohm (100 kHz to 1.8 GHz)

Time-gated spectrum analysis

Protective soft yellow operating/carrying case

Noise figure 7

GPIB interface 4, 22, 27

RS-232 interface 4, 22, 27

Parallel printer interface 22, 27

Protective soft tan operating/carrying case

Narrow resolution bandwidths

GPIB interface and parallel printer interface 4, 22, 26

RS-232 interface and parallel printer interface 4, 22, 26

Improved amplitude accuracy for NADC-TDMA/PCS bands

Improved amplitude accuracy for PDC bands

Improved amplitude accuracy for PHS band

Improved amplitude accuracy for CDMA/PCS cellular bands

PDC, PHS, NADC, and CDMA firmware for Option 15135

GSM900/DCS1800 firmware for Option 151

PDC/PHS/NADC/CDMA FW+Opt 151 retro. kit 35

DSP, fast ADC, and digital demodulator with
GSM900/DCS1800 firmware 35

TV picture on screen (NTSC, PAL, and SECAM)

R-S and true BER and PID statistics data measurements

Group delay retrofit kit

Quasi-peak detector and AM/FM demod retrofit kit

o R03

o R04

o R05

o R06

o R07/R17

o R10

o K10

o R11

o R15

o R16

o R19

o R21

o R23

o R24

o R25

o R30

o R41

o R43

o R50

o R51

o R52

o R53

o R60

o R63

o R70

o R73

o R80

o R95

o 11768A

o 11946A

35

Fast time-domain sweeps and analog + display

AM/FM demodulator with speaker and TV sync
trigger circuitry 5

o R01

o R02

Description

Option

1

1

1

1

2

2

0

0

0

0

0

0

0

0

1

0

0

0

0

1

0

0

0

1

0

1

1

1

0

0

1

1

Opt Card
Slots Req’d
(4 max)

ü

Std

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8591C

ü

ü

ü25

ü25

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8591E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü
ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8594E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8593E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8595E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

Std

ü

ü

8596E

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8590L

ü = compatible

ü

ü

ü

ü

ü

ü

ü

ü

8592L

ü

ü

ü

ü

ü

ü

8594L

Std

Std

Std

8594Q

Std

8590EM
Series

Agilent 8590 C/E/L/Q and EM Series Retrofit Kits 10

(for option installation after analyzer purchase)

128 Kbyte blank memory card (RAM)11

256 Kbyte blank memory card (RAM)11

512 Kbyte blank memory card (RAM)11

Link measurements personality

EMC measurements personality 12

Digital radio measurements personality 11

Scalar measurements personality 11

GSM900 measurements personality with modulation accuracy19

CT2-CAI measurements personality

NADC/PCS -TDMA measurements personality19

Noise figure measurements personality

PDC measurements personality upgrade kit: B to C

PDC measurements personality with modulation accuracy19

Cable TV measurements personality with video tests11,18,15

DCS1800 measurements personality with modulation accuracy

DECT measurements personality

Broadcast measurements personality

CDMA measurements personality

CDMA measurements personality upgrade kit: B to C

PHS measurements personality upgrade kit: A to B

PHS measurements personality with modulation accuracy

GSM Multi-band measurement personality

GSM Multi-band upgrade

o 85702A

o 85704A

o 85705A

o 11770A

o 85712D

o 85713A

o 85714A

o 85715B

o 85717A

o 85718B

o 85719A

o 85720BC

o 85720C

o 85721A

o 85722B

o 85723A

o 85724A

o 85725C

o 85725CU

o 85726AB

o 85726B

o 85727A

o 85727AU

Cable TV data management S/W for FCC 31

Benchlink spectrum analyzer

o 85921B

o E4444A

PC Software

32 Kbyte blank memory card (RAM)11

o 85700A

30

Description

Option

ü

ü

ü

Std

ü

ü

ü

ü

ü

ü

8591C

ü

ü33

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8591E

ü

ü

ü

ü33

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü33

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü
ü

ü

ü

ü

ü

8594E

ü

ü

ü

ü

8593E

ü = compatible

ü

ü33

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8595E

ü

ü33

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

8596E

ü

ü33

ü

ü

ü

ü

ü

ü

8590L

ü

ü33

ü

ü

ü

ü

ü

ü

8592L

ü

ü33

ü

ü

ü

ü

ü

8594L

ü

ü

ü

ü

ü

8594Q

ü

ü

ü

ü

ü

8590EM
Series

Agilent 8590 C/E/L/Q and EM Series Measurement Personalities 13

5

Agilent 8590 C/E/L/Q and EM Series Accessories
For Scalar Measurements
o 85630A

Scalar 50 Ohm transmission/reflection test set

o 86205A

50 Ohm RF bridge (type-N(f), 300 kHz to 6 GHz,
1.5 dB +0.1 dB/GHz insertion loss)

o 86207A

75 Ohm RF bridge (type-N(f), 300 kHz to 3 GHz,
1.5 dB +0.1 dB/GHz insertion loss)

For EMC Measurements
o 11945A

Close field probe set (9 kHz to 1 GHz) (with Option E51)16

o 11947A

Transient limiter (BNC(f) to type-N(m), 9 kHz to 200 MHz,
10 dB insertion loss)

Printers and Accessories

o 11867A

RF Limiter (type-N(f) to type-N(m), DC to 1.8 GHz, <.75 dB
insertion loss)

o 11930B

Power limiter (5 MHz to 6 GHz)

o 41800A

Active probe (5 Hz to 500 MHz)

o 85024A

High frequency probe (300 kHz to 3 GHz)

o 85901A

Portable AC power source

o 85902A

Burst carrier trigger

o 1420-0383

Memory card battery (CR 2016)

o 1494-0060

Rack slide for rack mount

o 08590-60369 RS-232/parallel connector assembly to convert Opt. 041
(GPIB) to Opt. 043 (RS-232)
o 08590-60368 GPIB/parallel connector assembly to convert Opt. 043
(RS-232) to Opt. 041 (GPIB)

Most Hewlett-Packard DeskJet and LaserJet (PCL 3 compatible) printers are
compatible with 8590 series spectrum analyzers. Printer compatibility chart
is on the internet web site at www.agilent/com/find/pcg/

o 9211-5604

Transit case

o 10833A

GPIB cable (1 meter)

o 5062-4841

o 24542U

RS-232 cable 3 meter (9 pin F to 9 pin F) Option 043 only
(for RS-232 9 pin PC connection to analyzer)

Rack mount without handles20 (centers instrument in
rack)

o 5062-4840

Rack mount with handles20 (centers instrument in rack)

o 5062-8240

Rack mount with handles 20 (mounts instrument left of
center)

o 5062-8241

Rack mount without handles 20 (mounts instrument left of
center)

o 24542G

RS-232 cable 3 meter (25 pin M to 9 pin F) Option 043
only (for RS-232 25 pin PC or printer connection to
analyzer)

o 24542M

RS-232 cable 3 meter (25 pin M to 9 pin F) Option 043
only (for RS-232 25 pin modem connection to analyzer)

o C2932A

RS-232 cable 3 meter (9 pin M to 9 pin F) Option 043 only
(for serial 9 pin LaserJet 4P/4Plus connection to
analyzer)

o 13242G

RS-232 cable (5 meter) (for Option 023 only)

o 08590-90234

8590 E/L Series user's guide

o C2950A

Parallel printer cable (2 meter)

o 08590-90243

8590 E/L Series quick reference guide

o ITEL-45CHVUB GPIB/Parallel converter (North America, Japan, Korea,
and Taiwan)
o ITEL-45CHVEB GPIB/Parallel converter (Continental Europe, U.K.,
Australia, and South Africa) (requires F1011A AC adapter)

Amplifiers and Preamplifiers

o 5180-9055

CRT viewing hood (sun shield)

o 5063-0654

Frequency accuracy retrofit kit for 8590B and 8590D

Agilent 8590 C/E/L/Q-Series Manuals
o 08590-90235

8590 Series programmer's guide

o 5960-6588

8590 E/L Series quick reference guide in French

o 5960-6590

8590 E/L Series quick reference guide in German

o 5960-6592

8590 E/L Series quick reference guide in Italian

o 5960-6594

8590 E/L Series quick reference guide in Spanish

o 8447D

Preamplifier (100 kHz to 1.3 GHz, >25 dB gain)

o 5960-6596

8590 E/L Series quick reference guide in Japanese

o 8449B

Preamplifier (1 GHz to 26.5 GHz, 30 dB gain)

o 08590-90260

8590 E/L Series user’s guide for Taiwan in Chinese

o 10855A

Broadband preamplifier (2 MHz to 1300 MHz, 22 dB gain)

o 08590-90261

8590 E/L Series user’s guide for China in Chinese

o 85905A

75 Ohm preamplifier (45 MHz to 1GHz, 20 dB gain)

o 5962-5001

8590 E/L Series user’s guide in French

o 87405A

Amplifier (10 MHz to 3 GHz, 22 dB gain)

o 5962-5002

8590 E/L Series user’s guide in German

o 87415A

Amplifier (2 GHz to 8 GHz, 25 dB gain)

o 08590-90286

8590 E/L Series user’s guide in Italian

o 5962-5004

8590 E/L Series user’s guide in Spanish

Other Accessories
o D4950A

Keyboard

o 08590-90269

8590L calibration guide

o 346B

Noise source (BNC(f) to APC 3.5(m), 10 MHz to 18 GHz)

o 08594-90183

859x C/E Series calibration guide

o 11693A

Limiter (type-N(f) to type-N(m), 0.1 GHz to 12.4 GHz,
<2.0 dB insertion loss)

o 08592-90082

8592L calibration guide

o 5963-2950

8590 C/E/L/Q Series assembly level repair guide

o 11694A

75/50 Ohm matching transformer (BNC(f) to BNC(m),
3 MHz-500 MHz, <.75 dB insertion loss)

o 5963-2951

8590 C/E/L/Q Series component level repair guide

o 08591-90129

8591C Cable TV analyzer user's guide, spectrum analyzer
reference

o 0955-1020

50 to 75 Ohm adapter. Same as Opt. 711

o 11742A

High frequency blocking capacitor (3.5mm(f to m)), 10 MHz
to 26.5 GHz, .35 dB IL <12.4 GHz, .7 dB IL <26.5 GHz)

o 08591-90176

8591C Cable TV analyzer user’s guide, cable TV measurements

o 11852B

Order with Option C04, 75/50 Ohm min. loss pad (typeN(f) to type-N(m), DC to 2 GHz, 5.7 dB insertion loss)

o 08591-90130

8591C getting started and quick reference guide

6

Agilent 8590 C/E/L/Q and EM Series Notes
1. For more information please contact your local Agilent sales
representative.
2. 8593 EM only
3. Quasi-peak detection and AM/FM demodulator is standard on 8590
EM-series and has additional capacity compared to Option 103.
4. Programming manual included
5. Options 101 and 102 required for TV sync trigger capability. See
Option 301.
6. 85717A measurement personality required
7. 85719A measurement personality required
8. ABF Quick reference and user’s guides in French
ABD Quick reference and user’s guides in German
ABZ Quick reference and user’s guides in Italian
ABE Quick reference and user’s guides in Spanish
ABJ Quick reference guide in Japanese
AB0 Quick reference guide for Taiwan in Chinese
AB2 Quick reference guide for China in Chinese
9. An incremental cost will be added to the base price of Options
W30/W32/W34/W50/W52/W54 for an 859xC/E/L/Q containing
Options 010, 011, or 130.
10. Parts only kits. No installation included. May require new analyzer
firmware.
11. Option 003 (card reader) on the 8590L, 8592L and 8594L is required.
12. For more information on EMC products and configurations see lit. number 5964-6089E.
13. Refer to measurement personality product literature for required 8590
series option configuration.
14. Except 8591 EM
15. Video tests not supported on 8590L, 8592L or 8594L.
16. Option E51 comes with preamplifier, carrying case, cables and
connectors.
17. Tracking generator retrofit requires factory installation of Option K10.
18. Cable TV measurements are formatted for local country's cable TV
standards.
19. Modulation accuracy measurements not supported on 8591E.
20. Rack height is 8.75 inches.
21. Not for analyzer operation while in carrying case
22. Options 021, 023 and 024 or 041 and 043 cannot be combined.
23. Not compatible with Option 107
24. Not compatible with other demodulator options (102, 103, 110, 112,
or 301).
25. Compatibility with 8591E limited to CDMA applications only
26. Compatible with serial prefixes 3523A or 3525U and higher
27. Compatible with serial prefixes lower than 3523A or 3525U
28. If Options 009 and 010 are combined on the 8593E/94E/95E/96E or
8590 EM series; only one option card slot is required.
29. Not compatible with Options 101 and 301
30. Requires Option 111. Not compatible with 8591E.
31. NTSC Cable TV analyzers only
32. Option 107 is not compatible with Option 180.
33. 85721 Cable TV measurement personality required
34. 11770A Link measurements personality required. Do not order Option
010 with Option 111.
35. Option 160 and 163 are not compatible.

7

Agilent Technologies’ Test and Measurement
Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive,
while minimizing your risk and problems. We strive to ensure
that you get the test and measurement capabilities you paid
for and obtain the support you need. Our extensive support
resources and services can help you choose the right Agilent
products for your applications and apply them successfully.
Every instrument and system we sell has a global warranty.
Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent’s
overall support policy: “Our Promise” and “Your Advantage.”
Our Promise
“Our Promise” means your Agilent test and measurement equipment will meet its advertised performance and functionality.
When you are choosing new equipment, we will help you with
product information, including realistic performance specifications and practical recommendations from experienced test
engineers. When you use Agilent equipment, we can verify that
it works properly, help with product operation, and provide
basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are
available.
Your Advantage
“Your Advantage” means that Agilent offers a wide range of
additional expert test and measurement services, which you
can purchase according to your unique technical and business
needs. Solve problems efficiently and gain a competitive edge
by contracting with us for calibration, extra-cost upgrades, outof-warranty repairs, and on-site education and training, as well
as design, system integration, project management, and other
professional services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity,
optimize the return on investment of your Agilent instruments
and systems, and obtain dependable measurement accuracy
for the life of those products.

By internet, phone, or fax, get assistance with all your
test and measurement needs.
Online Assistance

www.agilent.com/find/assist
Phone or Fax
United States:
(tel) 1 800 452 4844
Canada:
(tel) 1 877 894 4414
(fax) (905) 206 4120
Europe:
(tel) (31 20) 547 2323
(fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840
Latin America:
(tel) (305) 269 7500
(fax) (305) 269 7599
Australia:
(tel) 1 800 629 485
(fax) (61 3) 9272 0749
New Zealand:
(tel) 0 800 738 378
(fax) (64 4) 495 8950
Asia Pacific:
(tel) (852) 3197 7777
(fax) (852) 2506 9284
Product specifications and descriptions in this
document subject to change without notice.
Copyright © 1998, 2000 Agilent Technologies
Printed in U.S.A. 7/00
5963-6858E



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Create Date                     : 1910:00:62 11:12:70
Producer                        : Acrobat Distiller Daemon 3.0 for HP-UX A.09.01 and later (HPPA)
EXIF Metadata provided by EXIF.tools

Navigation menu