- INSTRUCTIONS -
LEF-5-NE/LEW-5-NE
5-call Master Station
Master Station for use with the NEM and NDR Systems
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
LEF-5-NE Instr.
Page 1
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
K4
L5
K5
LE
RF
1
2
Blk
+
-
1
2
3
4
5
~
40
E
H
Q
+
-
PS-2420UL
NDR-40 LEW-5-NE/B
Adaptor
NE-DA
+
-
PS-1225UL
The LEF-5-NE is a 5-station master, equipped with a door release button, and able to integrate into a larger
NEM or NDR system. In applications where up to 5 door stations needs to be answered from the main NEM/
NDR master as well as additional small master stations, the LEF-5-NE can be used. The LEW-5-NE adaptor
is required. This system can be used with the following subs: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C,
NE-NVP-2DC-LE, NE-NVP-RA.
NOTE: Standard LE-series sub stations cannot be used
in a system with the LEF-5-NE master stations. The LED
timing circuit in the LEF is modified.
The NA-A and NA-AN also cannot be used to call the
LEF-5-NE, but can be connected directly to the NDR/
NDRM master station.
NE-JA
Wire each door
station to a
designated
number station
as shown here.
To Door
Strike for
Door #4
To Door
Strike for
Door #1
1
2
3
4
Blk
Grn
RY-PA BlkYel
RY-PA BlkYel
Diode value:
1N4001 ~ 4007
1
K1
2
K2
3
K3
4
K4
5
C
E
R
L
+
-
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
C
5
E
R
L
+
-
LEF-5-NE
"K" Terminal connections
are required in this
application, with or without
door release being included.
Leave jumper
intact
WIRING DIAGRAM: using NE-DA and NE-JA subs
0113
RY-PA BlkYel
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Page 2
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
K4
L5
K5
LE
RF
Red
Blk
Wht
+
-
1
2
3
4
5
~
40
E
H
Q
+
-
PS-2420UL
NDR-40 LEW-5-NE/B
Adaptor
NE-SS/SSR
+
-
PS-1225UL
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L
+
-
LEF-5-NE
Wire each door
station to a
designated
number station
as shown here.
To Door
Strike for
Door #5
RY-PA BlkYel
To Door
Strike for
Door #1
Diode value:
1N4001 ~ 4007
Red
Blk
Wht
Pur
Blu
Org
Org
Yel
Yel
NE-NVP-2DC-LE
Grn
wire
Grn
wire
NOTE: "K"
Terminal
connections are
required in this
application, with
or without door
release being
included.
WIRING DIAGRAM: using NE-SS/SSR and NE-NVP-2DC-LE subs
RY-PA BlkYel
To Door
Strike for
Door #5
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
K4
L5
K5
LE
RF
+
-
PS-2420UL
NDR-20A-RS LEW-5-NE/B
Adaptor
NE-NVP-RA
+
-
PS-1225UL
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L
+
-
LEF-5-NE
Wire each
station to a
designated
number station
as shown here.
RY-PA BlkYel
To Door
Strike for
Door #1
Diode value:
1N4001 ~ 4007
NOTE: "K"
Terminal
connections are
required in this
application, with
or without door
release being
included.
Blue
Blue
NAR-2A*
* Reset Button:
(Any normally closed
button or keyswitch.
Not required when
using the NEM-RS
master.)
1
2
3
4
5
~
20
E
H
Q
S
+
-
Red
Blk
Gray
Blue
Pur
Org
Yel
Grn
wire
Red
Blk
Wht
NE-NVP/C
WIRING DIAGRAM: using NE-NVP-RA and NE-NVP/C subs
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Page 3
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Page 4
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
K4
L5
K5
LE
RF
-
+
PS-1225UL
LEW-5-NE/B
Adaptor
+
-
PS-1225UL
1
K1
2
3
4
C
5
E
R
L
+
-
LEF-5-NE
Red
Blk
Wht
Pur
Blu
Org
Org
Yel
Yel
NE-NVP-2DC-LE
Grn
wire
1
K1
2
3
4
5
C
E
R
L
+
-
LEF-5-NE Connect with wires
of the standard call button
to activate a call when the
RED button is pressed.
WIRING DIAGRAM: with no NEM or NDR master being used
OPERATION:
1. Pressing the call button at the door/sub station will activate the call tone, plus light the
appropriate station LED at the NEM/NDR master. The call tone will be heard at the LEF-5-NE
master(s) continually until the call is answered from any master in the system.
2. To answer the call on the LEF or NEM/NDR master, press the station button corresponding to
the lit LED, then press TALK to speak to the visitor. When the first master answers the call,
the Occupied lamp will be lit on all other masters. DO NOT answer the call if the Occupied
lamp is lit.
3. Communication at the master station is "press-to-talk, release-to-listen". Communication at
the door station is hands free.
4. With communication established to the door station, pressing the door release button will
activate the door release mechanism at the corresponding door.
5. When the call is completed, press OFF on the LEF master, or the associated black OFF
button on the NEM/NDR master. The Occupied lamp will go out on all masters when the call
is cancelled.
SPECIFICATIONS:
Power Source: 12V DC at master. Use PS-1225UL.
Communication Output: 800mW @ 20 ohms (receive); 500mW @ 20 ohms (transmit)
Communication: Push-to-talk, release-to-listen at master station.
Hands free at sub station.
Calling: Master to sub: By voice
Sub to master: Mono-electronic call tone
Compatible Remotes: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C, NE-NVP-2DC-LE,
NE-NVP-RA
Wiring: 3 conductors from door/sub to LEW-5/NE Adaptor (Aiphone #822203)
2 common plus 2 individual conductors per door from
LEW-5-NE to LEF-5-NE (Max. 12 conductors with 5 door stns)
(Aiphone #822212)
7 conductors from LEW-NE to NEM/NDR master (Aiphone #822212)
2 conductors from master to their respective power supply.
Shielded cable is recommended.
Wiring Distance: 420' with 22AWG; 1,000' with 18AWG.
Dimensions (H x W x D): 7" x 5-1/2" x 2-1/4" (dimensions are for the LEW-5-NE)
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Page 5
LEF-5-NE Instr.
0113PH
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com