Aiphone IER 2‘oŠÍ 2 Installation And Operation Manual Instr
User Manual: Aiphone IER-2 Installation and Operation Manual Instructions
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
FK1829 0709 A CALL EXTENSION Model; IER-2, Call extension speaker INSTALLATION & OPERATION MANUAL PACKAGE CONTENTS . Call extension Speaker (IER-2) . Packet of screws . Installation & Operation Manual IER-2 Precautions on Installation In order that the product can be used safely and properly, please observe the following Precautions. CAUTION (Negligence could result in injury or damage to property.) Mount IER-2 in a convenient location, but not where it could be bumped or jarred. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit. Do not install IER-2 in any of the following locations, as it may cause the system to malfunction; . High or extreme cold temperature area: under direct sunlight, near equipment that varies in temperature, in front of air conditioner, inside a refrigerated area, etc. . Places subject to moisture or humidity extremes (bathroom, cellar, greenhouse, etc.) . Places subject to environmental conditions, such as oil, dust, chemicals, salt, etc. . Places subject to steam or smoke (near heating equipment or cooking surfaces) 1 SYSTEM OUTLINE & COMPONENTS IER-2 2 e Chim dio or aeu n o t The IER-2 is a call extension speaker for hearing a chime tone in a location remote from the master or sub station. The chime is the same from the IER-2 as is emitted from the intercom, and it is equipped with a 3-position volume switch. There is no reply from the IER-2. Intercom master or sub station 2 NAMES & FEATURES IER-2 FEATURES . Announces a call tone. No communication. . One speaker for the master (or sub) station. . Volume adjustment to 3 positions. . Surface-wall single-gang mounting. Speaker Call tone volume control Screw hole (x2) -1- 3 5 MOUNTING 1. Connect a pair of wires to screw terminals on back. 2. Attach IER-2 unit to wall or single-gang box with supplied screws. 3. For surface-wall mounting, run the cable either from top or bottom of the unit. OPERATIONS Adjusting call tone volume HIGH AIPHONE IER-2 MEDIUM . Single-gang wall mounting . Surface-wall mounting IER-2 Sinlge-gang box IER-2 LOW x Wall 83.5mm (3-5/16") x When call tone sounds, there is no communication. To reply, come to the inside station. Screw (x2) Wood screw (x2) Connecting cable Connecting cable . Make a cable inlet hole in the top. 6 Remove Mounting location IER-2 is not a weather-resistant type. Do not install outdoors. Back view (top, right) 4 WIRING 7 IER-2 Intercom master or sub station 1 Non-polarized TECHNICAL PRECAUTIONS Cleaning Clean IER-2 unit with a soft cloth dampened with neutral household cleanser. Never use any abrasive cleaner or cloth. E SPECIFICATIONS (IER-2) . Unit housing: Plastic . Wiring: 2 wires, non-polarized to an inside station (master or sub). . Dimensions:120H x 88W x 29D (mm). 4-3/4"H x 3-1/2"W x 1-1/8"D. . Weight: 150g (0.33 lbs.). Connecting terminals may vary by intercom station. Refer to the Manual packed with the intercom station. WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the product. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE IER-2-I(E) 0709A -2- http://www.aiphone.net/ Printed in Vietnam(E)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Author : wata Create Date : 2011:11:04 13:44:57Z Modify Date : 2013:03:07 16:08:54-08:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : wata Title : IER-2‘oŠÍ Creator Tool : QuarkXPressþ: AdobePS 8.7.2 (104) Metadata Date : 2013:03:07 16:08:54-08:00 Producer : Acrobat Distiller 4.05 for Macintosh Document ID : uuid:8251963a-5751-4089-89de-74903c3729e0 Instance ID : uuid:2f138dfa-30a9-4409-9f6f-5085fc29b9ce Page Count : 2EXIF Metadata provided by EXIF.tools