Aiphone IX PA Network Paging Adapter Installation Instructions
User Manual: Aiphone IX-PA Network Paging Adapter Installation Instructions
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
1016 IX SERIES IX-PA Network Paging Adaptor Installation & Programming Guide 1 4 GHI 7 PQRS 2 3 ABC DEF 5 6 JKL PRIVACY TRANSFER 8 WXYZ 0 # IX System IX System IX System IP network-compatible intercom IP network-compatible intercom IP network-compatible intercom Master Station (IX-MV) Video Door Station (IX-DA) Audio Only Door Station (IX-BA) Web Setting Manual Software version 2.0.0.0 or later Software version 2.00 or later Before configuring and using the system, read Setting Manual and Operation Manual (PDF) carefully. *For the installation and connection of each device, refer to Installation Manual. Before configuring and using the system, read Setting Manual and Operation Manual (PDF) carefully. *For the installation and connection of each device, refer to Installation Manual. Important Important SETTING 9 TUV IX-MV IX Support Tool Setting Manual LIST MNO IX-PA Web Setting Manual Software version 2.00 or later Before configuring and using the system, read Setting Manual and Operation Manual (PDF) carefully. *For the installation and connection of each device, refer to Installation Manual. Important y Begin installation after reading and understanding the procedures for system configuration. y Begin installation after reading and understanding the procedures for system configuration. y The setting data should be backed up and stored in a safe location after configuration is complete. y The setting data should be backed up and stored in a safe location after configuration is complete. y The setting data should be backed up and stored in a safe location after configuration is complete. The illustrations and images in this manual may vary from the actual ones. The illustrations and images in this manual may vary from the actual ones. The illustrations and images in this manual may vary from the actual ones. y Begin installation after reading and understanding the procedures for system configuration. ATTENTION: This is an installation and programming manual addressing wiring and programming for the IX-PA paging adaptor. For general IX Series programming, a complete set of instructions (IX Web Setting Manual / IX Operation Manual / IX Support Tool Setting Manual) can be found on the DVD-ROM provided with the IX-MV master station. WIRING: The IX-PA is a paging adaptor designed for use with the Aiphone IX Series network intercom system. The paging adaptor has an address book that supports up to 50 stations and can be connected to 3rd party devices. The paging adaptor can be accessed by an IX-MV master station or an instance of the IX Mobile App to allow messages to be broadcast through the IX-PA 600Ω or 8Ω output. A 3rd party device can be connected to the audio input to send messages to the paging adaptor's address book. IX-PA IX-MV PoE Switch CAT5e / CAT6 1 4 GHI 7 PQRS 2 ABC 5 JKL 8 3 DEF 6 PRIVACY TRANSFER LIST SETTING MNO 9 TUV WXYZ 0 # Audio Input Trigger Input 600Ω Output 8Ω Speaker Output (5 W) Step 1: Logging into the IX-PA Paging Adaptor IMPORTANT! The IX Series equipment must be programmed and operational prior to programming the IX-PA paging adaptor. The IX-PA adaptor is defaulted to DHCP. When it powers on with factory default settings, it will request a DHCP address. If it does not receive one, it will wait for any computer using ARP to locate X.X.X.168 and respond, and then use that address until it is rebooted or a static IP address is assigned. The assigned IP address will be announced through the 8Ω speaker (if attached). When a static address is assigned, it will not request DHCP nor listen for .168, it will simply power on with the address assigned. Enter the announced or default .168 IP address into a web browser address bar to access the IX-PA. Step 2: Assigning Station Information Once logged into the adaptor, the Station Information screen shows Station Number, Station Name, and Location assignments. An optional Web Password can also be assigned to the adaptor from this screen to prevent unauthorized access. Note the Station Number & Station Name for use in Step 7: Adding the IX-PA to an IX Series System. After entering a unique Station Number and Station Name, click the button to save and restart the adaptor. Step 3: Network Settings Select Network Settings from the menu on the left. Enter a unique IP Address*, Subnet Mask, and Gateway IP Address. Consult with your IT department for the appropriate addresses to be assigned. * If changes are made to the IP address, the web browser will need to be redirected to the new IP address after updating. There are additional settings on the Network Settings page that can be adjusted: SIP Settings, Audio Settings, and Packet Priority. The default settings will work in most cases. Adjust as necessary. Note any Network Settings changes for use in Step 8: Assigning IP Address. Click the button to save any Network Settings changes and restart the adaptor. 2 | IX-PA Installation & Programming Guide Step 4: Paging Settings / Address Book Select Paging Settings from the menu on the left. The Paging Pretone heard from speakers connected to this adaptor can be selected. Rebroadcast to this station's address book can be enabled, allowing any page the IX-PA receives sent to all stations in its address book. Under Outgoing Paging Settings, the Trigger Input Setting, Paging Priority, Paging Timeout, and Paging Response Timeout can all be adjusted. The Address Book destinations will need to be populated if the paging adaptor is to be used to broadcast a 3rd party source to the IX Series stations. These destination IP addresses will need to match those in the programmed IX Series system. A maximum of 50 stations can reside in the paging adaptor's address book. Click the button to save any Paging Settings and Address Book changes and restart the adaptor. Step 5: Station Hardware Settings (optional) Select Station Hardware Settings from the menu on the left. From this screen, Output Volume, Input Sensitivity, Input Gain, and Input Source can be adjusted. The Output Volume by default is set to the max level. Use the drop down to select the desired output if it needs to be lowered. The Input Sensitivity can be adjusted between Low, Normal, and High by using the drop down. The Input Gain can be adjusted between Normal, High, and Max by using the drop down. Select between Microphone and Line using the Input Source drop down. Click the button to save the Station Hardware Settings and restart the adaptor. Step 6: Maintenance (optional) Select Maintenance from the menu on the left. If a Syslog server is being used on the network, the IP address for the server can be entered here. If Syslog Address remains 0.0.0.0, the log will be broadcast. Enable Debug Mode for additional Syslog messages to aid in troubleshooting. The adaptor can also be restored to factory defaults, the firmware can be updated, or can be rebooted from the Maintenance window. Click the button to save Syslog Address / Debug Mode settings and restart the adaptor. 3 Step 7: Adding the IX-PA to an IX Series System Now that the IX-PA has been programmed, the IX Series system must be updated to see the adaptor. Open the IX Support Tool and select the system to be updated. From the menu on left, select Identification from the Station Information tree. On the next available line, enter the number and name of the IX-PA assigned in Step 2. Select Master Station from the Type drop down. Click the button to save changes. Step 8: Assigning IP Address Now that the paging adaptor has been added, the IP address will need to be assigned. From the menu on the left, select IP Address from the Network Settings tree. The newly added station will be in the list of stations, but the IP Address and Subnet Mask will be blank. Enter the IP Address and Subnet Mask, making sure it matches what was set to the IX-PA during its initial programming in Step 3. Click the button to save changes. Step 9: Creating a Group Select Group from the System Information tree on the left. Scroll to the right and find the master station on the top of the page. For the next available group, assign a group number and group name. Locate the paging adaptor from the list of stations below and select U. Repeat this process for each master that needs to page the IX-PA. Click the button to save changes. Click File, Upload Settings to Stations. Select the stations where any changes were made from the stations listed (i.e. masters). Click Start Upload to upload the settings to the stations. Important: The IX-PA can only be "paged" from an IX-MV master. In order to page the device, it must be a group or part of a group. If the device is called indivdually or the group is called, a call failed error will occur. It is recommended to set up one of the speed dial buttons on the IX-MV to be used for paging the group that the IX-PA adaptor resides in. Aiphone Corporation | www.aiphone.com | tech@aiphone.com | (800) 692-0200 4 | IX-PA Installation & Programming Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29 Create Date : 2016:10:11 09:39:14-07:00 Metadata Date : 2016:10:18 07:23:45-07:00 Modify Date : 2016:10:18 07:23:45-07:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:3ee29f36-8c8c-4c95-9142-e48eeb332791 Original Document ID : xmp.did:5BAF4E920BA5E111B0738D6FC4D8F15A Document ID : xmp.id:785a02e9-d2c5-534c-b0a6-6ba24695be4a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:b6bee500-079a-d543-b602-7fbee7bc467e Derived From Document ID : xmp.did:ae086ab9-6813-6842-9303-40a341198673 Derived From Original Document ID: xmp.did:5BAF4E920BA5E111B0738D6FC4D8F15A Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2016:10:11 09:39:14-07:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools